The TwinMic beamline at Elettra synchrotron has been active in the past few decades in research fields such as medicine, pharmacology, toxicology and environmental science, offering combined scanning transmission X-ray and X-ray fluorescence microscopy. Here, we present the recent advances of TwinMic in performing micro X-ray absorption near edge spectroscopy on biological specimens.
Different components of cells or tissues can play different roles in the function and reaction of cells and organs. They can respond in different ways to external agents like drugs or pollutants, thus the potentiality of selectively discerning which part acts in which way is of crucial importance.1–4
X-ray fluorescence (XRF) microscopy is a well-established technique for chemically mapping biological objects with sub-micrometric spatial resolution.5
Exciting the atoms of the sample at a specific incident energy enables the detection and localization of several chemical elements whose transition energies of K or L-edges are below the incident energy. Often the technique is performed in raster-scanning mode to reconstruct the elemental maps pixel by pixel, moving the sample across the incident beam. Some synchrotron beamlines combine XRF microscopy with the absorption one in order to simultaneously obtain morphological and chemical information.6,7
XRF microscopy aside, the spectroscopic part can be integrated through XANES (X-ray Absorption Near Edge Spectroscopy), recording a stack of images at different incident energies. The main advantage of XANES is the identification of the chemical state of the probed elements whereas XRF microscopy allows identifying the element with no robust hint of its oxidation or bonding condition.8 XANES detection modes include a variety of options exploiting direct and indirect photons emissions. In the soft X-ray regime, XANES can be collected as the attenuation of the incident beam after the interaction with the sample (transmission mode) or in fluorescence mode, integrating the spectral signal of the emitted photons for all the energies below the excited one.9 For this last case, the spectroscopic discrimination of the emitted photons is not required, since the energy parameter is determined by the incident beam. The detection can be performed with a photodiode or a photomultiplier, indeed. However, spectral resolution in the XRF detectors is more advisable for discriminating the signal from background or any other noise component. In some cases, the two detection modes, transmission and fluorescence, give similar spectra but the effects of self-absorption have to be considered, particularly in dense samples.
In the soft X-ray regime, where the samples must be thin enough to allow light to be transmitted through the specimens, the XRF signal is expected to show an improved signal to noise level compared to the transmitted one, given that the recorded signal is proportional to the probability of the fluorescence emission and is not directly dependent on the quantity of the transmitted light.
The presented work shows a versatile XANES-based method deployed at the TwinMic beamline of Elettra Sincrotrone Trieste (Trieste, Italy)10 for achieving more complete spectroscopic characterization of biological samples.
Micro-XANES coupled with Scanning Transmission X-ray Microscopy (STXM) is nowadays a routine technique in several synchrotron beamlines, mainly applied to materials science,11–14 meteoritics15 or meteorology16 and more rarely to biological samples.17–19
Most soft X-ray microscopy beamlines have opted for acquiring stacks of images in transmission mode, exploiting the already existing and optimised STXM setup, as it turns out to be the most rapid acquisition mode. A few beamlines would have the possibility to acquire the spectra in XRF mode, as they also have an integrated XRF detector in the microscope. However, to our knowledge such an option is not exploited. In order to acquire high energy resolution spectra, several XRF maps need to be collected but this acquisition is usually slower than the corresponding STXM images collection, due to the small solid angle acceptance of the XRF detectors and the low XRF yield below 2 keV.
With the current work, we demonstrate the feasibility of both absorption and XRF mode acquisition for XANES soft X-ray measurements in a simultaneous way.
The method here presented has so far been successfully tested only on material science samples at TwinMic. Here, we focused on its implementation on biological samples, whose unordered structures and generally lower concentrations of elements of interest make this application more challenging. As most of the samples investigated at the TwinMic beamline come from the life science field, incorporating such spectroscopy into the already existing imaging techniques will considerably improve the beamline capability, providing more comprehensive information on biological processes.20,21
The approach exploits the TwinMic configuration which was conceived for performing STXM and XRF in parallel in the soft X-ray range (400–2200 eV) with a submicrometric spatial resolution.
Stacks of STXM images are collected at different incident energies in the range of a specific absorption edge. In the meantime, also the XRF signal emitted from the excited atoms of the sample is collected. This provides the possibility to process micro-spectra simultaneously collected both in transmission and fluorescence modes.
Two representative cases are shown for this proof of principle investigation: (i) Al K-edge spectra of a soybean (Glycine max) root section exposed to Al. Details of previous studies on this sample can be found in ref. 22; (ii) Fe L2,3-edges spectra in glioblastoma multiforme (GBM) cells treated with Fe oxide nanoparticles (NPs).23
X-rays can damage biological samples during the XANES and/or the XRF acquisition, especially in the soft X-ray regime where the absorption cross section for the light elements is considerably higher compared to the hard X-ray.
The damage process is extremely complex and several aspects can contribute even in an ambiguous way. For instance, the vacuum condition, necessary for performing X-ray analysis in the soft regime, can both reduce the oxidation effect and at the same time can favor the dehydration conditions of the sample.24
Even if the damage effect is unavoidable in such a kind of investigation, XANES in itself can help to detect an eventual alteration of the sample condition performing spectrum replicas at different experimental stages. However, even if the spectra are identical, this can also indicate that the changes happened at the beginning of the process and thus, a sample alteration cannot be completely excluded.2
The details of the preparation of the GBM cells exposed to Fe oxide NPs are available in ref. 23.
In particular, for performing the experiment at the TwinMic beamline, the sample was seeded on 200 nm-thick silicon nitride membranes (NanoVision). After 24 h, the membranes were transferred to WillCo dishes and treated with 100 µg mL−1 of cell-derived Fe oxide NPs. The sample was fixed with 4% PFA at 4 °C for 20 min, washed twice with Dulbecco's phosphate-buffered saline, and then rinsed twice with water. The sample was then dehydrated before analysis.
The transmitted X-rays are collected with an electron multiplying CCD (EMCCD) camera DV860 from Andor Technology (128 × 128 pixels, 24 × 24 µm2 pixel size) through an X-ray-visible light converter consisting of a P43 phosphor screen, a lens, a mirror tilted by 45° and an objective lens.
Employing a 2D-type detector instead of a point one allows collecting the differential phase contrast (DPC) signal together with the absorption one.25,26
Simultaneously, the XRF photons emitted by the sample are collected by eight silicon drift detectors (SDDs) located symmetrically at 20° from the sample plane. The output signal of the preamplifier electronics (XGLab srl, Bruker Nano-Analytics) is processed through the DANTE Digital Pulse Processor (XGLab srl, Bruker Bruker Nano-Analytics).
A preliminary XRF map was collected on the Al treated specimen. The scanned area is of 40 × 80 µm2 size, with a stepsize of 0.5 µm (0.69 µm of beam size diameter), with an incident energy of 1.72 keV and a dwell time of 3 s per pixel in order to detect where the Al was mostly localized. The XRF spectra were fitted using PyMCA program.27
Then, a sub-area of 10 × 10 µm2 (same stepsize) was selected to collect a stack of STXM images and XRF maps with a dwell time of 10 ms per pixel and 1 s per pixel, respectively. The incident energy was varied in the range from 1.55 keV to 1.57 keV with a stepsize of 0.25 eV.
A stack of images and maps was collected for a prepared 1µm-thick film of metallic Al standard, under the same experimental conditions. The Al film was deposited through DC magnetron sputtering, using an Al metal target on a Si3N4 membrane of 100 nm thickness. The metallic state of the standard was checked by X-ray diffraction and XANES in total electron yield measurements.
Similarly, a preliminary XRF map was collected on the Fe-treated specimen. The scanned area is of 35 × 35 µm2 size, with a stepsize of 0.5 µm (0.6 µm of beam size diameter), with an incident energy of 1.5 keV and a dwell time of 2 s per pixel in order to detect where the Fe NPs were mostly localized and to identify the distribution of the elements of the major interest for cells, namely Na and Mg.28 The XRF spectra were fitted using PyMCA program.
Then, a sub-area of 20 × 20 µm2 (with the same stepsize) was scanned for collecting a stack of STXM images and XRF maps with a dwell time of 40 ms per pixel and 1 s per pixel, respectively. The incident energy was varied in the range from 0.705 keV to 0.744 keV with a stepsize of 1 eV.
During STXM energy scans, lateral sample shifts were observed, arising not only from thermal drift but also from micro-tilting of the zone plate and changes in focal distance. These effects were partially compensated during acquisition by refocusing along the beam direction and correcting beam displacements in the x and y plane of the sample. Residual misalignments were corrected during data processing using a custom Python pipeline that implements modular subpixel alignment algorithms (phase correlation29 and SIFT-based30). To ensure robustness across datasets, different reference frames (fixed index or previous frame) and contrast modes (absorption, phase, transmission function, or XRF) could be selected. Final absorption and XRF stacks were produced by cropping to the maximum common overlapping region.
The original areas of 10 × 10 µm2 and 20 × 20 µm2 have been reduced to 8 × 7 µm2 and to 14.5 × 15.5 µm2, respectively, due to the alignment process.
Both of the signals (STXM and XRF) were processed by integrating them for a reduced number of pixels inside and outside of the sample and calculated as:
Spectra were then normalized between 0 and 1 in order to overlap each other for comparison.
Fig. 2 shows the XANES spectra of a selected subarea of 3 × 3 µm2 obtained from the stack of the STXM images and from the stack of the XRF signal. In particular, the subregion of 10 × 10 µm2 was selected from the preliminary scanned area of Fig. 1 due to the high photon counts at the Al K-edge. STXM and the corresponding XRF scans were collected for each incident energy. After the alignment post-processing of the stack of images, the total area was reduced to 8 × 7 µm2. Spectra were obtained following the procedure explained in the Methods section.
A similar stack of images was acquired for the Al standard sample. Fig. 3 shows the comparison between the spectra of the root sample (acquired in XRF mode) and the Al standard (acquired in transmission mode).
![]() | ||
| Fig. 3 Al K-edge XANES spectra of the selected subarea of the soybean root sample acquired in XRF mode (green) and of the Al standard acquired in transmission mode (black). | ||
For the energy stack measurements, the central area of the cell of dimension 20 × 20 µm2 (yellow square in Fig. 4) was selected.
Fig. 5 shows the XANES spectra obtained integrating both the transmission and XRF signals in a subarea of 2 × 2 µm2.
The I0 signal was calculated integrating the transmission from a 1 × 1 µm2 square of the top left corner of the scanned area, where no cell and Fe oxide NPs show a detectable signal.
As in the case of Al K-edge XANES, the spectra were then normalized between 0 and 1 in order to overlap each other for comparison.
Al K-edge is an interesting but extremely complex edge where remarkable shifts in the energy range can be observed passing from the metal to the oxidized state. Apart from energy position, the spectral shape is also extremely complex even for the same oxide, e.g., alumina (Al2O3), with different crystal order, e.g., γ-Al2O3 and θ-Al2O3.33,34
In order to verify the energy position of the Al K-edge in these systems compared to metal and alumina samples, measurements were performed under the same experimental conditions, on a metallic Al film (Fig. 3).
The energy position of the Al K-edge indeed appears to confirm the non-metallic state of the Al-treated root.
No additional Al standards could be measured during the experiment. However, the reported results demonstrate the capability of the TwinMic beamline to perform Al K-edge XANES measurements on biological systems and to discriminate between metal and oxide states.
It is important to stress that the XANES micro-spectrum in fluorescence mode shows a signal to noise level comparable to the data obtained on soybean root samples prepared under similar conditions,32 considering also that in ref. 32 the final spectra were collected on a considerably higher amount of the specimen and as a result of an average of 60 scans from different regions within the same sample.
The NPs look mainly localized in the peripheral region. Even if the Fe L-edges XANES signal is detectable in several cell subregions; a representative subarea was selected for showing the spectra measured both in transmission and fluorescence modes. The spectra show the typical Fe L2,3 edges shape. The selected energy resolution (1 eV) does not allow for discriminating the spectral shape differences between the metal and the oxide states. However, the results prove the capability of the TwinMic beamline to detect XANES spectra, with a good level of signal to noise, also at a soft X-ray L-edge energy.
Being able to measure XANES at L-edges for transition metals is crucial for several research fields. Compared to K-edges, XANES for the L-orbital symmetry represents a more efficient probe of the coordination of transition metals since any variation is detectable with a better energy resolution and a direct variation in the spectral shape.35
Notably, the multimodal acquisition system of the TwinMic beamline enables the simultaneous collection of micro-XANES spectra in both transmission and fluorescence modes, offering a rare capability worldwide and allowing cross-validation of the results. There are a few other soft X-rays synchrotron beamlines which could use both XANES modes but to our knowledge there is no mention of their simultaneous combination in the literature. Here, we demonstrate the feasibility of such parallel XANES acquisition. With the ongoing upgrade of Elettra 2.0 (ref. 36), both the increased stability and brilliance of the photon source will contribute to further improving TwinMic performances, XANES acquisition capabilities included.