Open Access Article
Warren R. L.
Cairns
*a,
Emma C.
Braysher
b,
Owen T.
Butler
c,
Olga
Cavoura
d,
Christine M.
Davidson
e,
Jose Luis
Todoli Torro
f and
Marcus
von der Au
g
aCNR-ISP and Universita Ca’ Foscari, Via Torino 155, 30123 Venezia, Italy. E-mail: warrenraymondlee.cairns@cnr.it
bNational Physical Laboratory, Hampton Road, Teddington, Middlesex TW11 0LW, UK
cHealth and Safety Executive, Harpur Hill, Buxton, SK17 9JN, UK
dSchool of Public Health, University of West Attica, Leof Alexandras 196, 115 21 Athens, Greece
eDepartment of Pure and Applied Chemistry, University of Strathclyde, 295 Cathedral Street, Glasgow, G1 1XL, UK
fDepartment of Analytical Chemistry, Nutrition and Food Sciences University of Alicante, 03690 San Vicente del Raspeig, Alicante, Spain
gFederal Institute for Materials Research and Testing, Richard-Willstätter-Straße 11, 12489 Berlin, Germany
First published on 16th December 2025
Highlights in the field of air analysis included: development of laboratory-based particle emission simulators to emulate real-world processes such as tyre-wear abrasion; ongoing performance verification of Hg calibrators; progress in laser and spark emission spectroscopic techniques for in situ aerosol measurements, advances in data processing software tools in supporting sp-ICP-MS measurements, feasibility of using aerosol mass spectrometers for measuring nanoplastics in air, and a comprehensive review of brown carbon aerosols, its sources, optical properties and measurement approaches used. While recent developments in water analysis include significant progress in sp-ICP-MS, including the introduction of new measurement protocols, determination of isotope ratios, and new reference materials. The number of studies employing LIBS for assessing metal burdens in water has also grown notably, particularly with respect to innovations in sample preparation. Advances were further reported in the development of portable analytical devices and systems for continuous environmental water monitoring. In addition, several comprehensive reviews were published, providing guidance for researchers on establishing robust measurement workflows, including split-stream and sp-ICP-MS methodologies. In the analysis of plants and soils, there has been increased interest in deep eutectic solvents as milder and greener alternatives to traditional extractants. Microwave plasma torch mass spectrometry methods have been developed that allowed concurrent measurement of trace elements and organic pollutants in liquid samples. Promising steps have also been taken towards application of techniques for direct analysis of solids. Advances in LIBS have largely focussed on data processing and modelling whilst in XRF, the influence of soil matrix composition on measurement accuracy was highlighted. Quantitative geochemical analysis faces continuous challenges, making the development of new RMs a persistent priority, especially for localized microanalysis. Application of LIBS is gaining increasing interest because of its portability and the use of machine learning tools to improve the quality of the obtained data. Interest is also increasing in the analysis of extraterrestrial samples. Novel ICP-MS instrumentation has offered highly precise isotopic analysis and spectral interference removal. Other important techniques in this review period have been nanoSIMS, NAA, and MS variants because they may provide new and enhanced chemical information. The fusion of data and the significantly increasing application of AI for rapid mineral identification and data integration marks a key trend that is expected to grow exponentially.
All the ASU reviews adhere to a number of conventions. An italicised word or phrase close to the beginning of each paragraph highlights the subject area of that individual paragraph. A list of abbreviations used in this review appears at the end. It is a convention of ASUs that information given in the paper being reported on is presented in the past tense whereas the views of the ASU reviewers are presented in the present tense.
Progress in determining the composition and morphology of atmospheric particulates was the focus of three reviews. In the first review9 (115 references), the principles, advantages and limitations of analytical techniques for determining the physiochemical properties of ultrafine particles of <100 nm were summarised. Such techniques were broadly grouped into the following categories: electron and X-ray microscopy, optical spectroscopy and microscopy, electrical mobility and mass spectrometry. In the second review10 (302 references), while it was noted that the development of analysis methodologies has helped shape our understanding of new particle formation from gaseous precursor species, further improvements were outlined. These included the development of cheaper, more robust and easier to use particle sizing instrumentation, better measurement methods to detect and quantify low concentrations of precursor vapours and improved analytical tools for determining the composition of the resultant particles formed in the 2–20 nm size range. The reviewers concluded that there is a need for better measurement harmonisation and suggested that standard operation procedures be published and common calibration and intercomparison practices be adopted. In the third paper, various instrumental approaches for determining the RCS content in APM, spanning IR and XRD techniques that are currently used to emerging QCL-IR and Raman-based techniques, were reviewed11 (160 references).
Applications and developments in air sampling instrumentation are summarised in Table 1.
| Analyte | Sample matrix | Study rationale | Findings | References |
|---|---|---|---|---|
| APM | Air | Development of an new automated air sampler device for collection of samples at high time resolution | Compact and transportable STRAS (size and time resolved aerosol sampler) sampler for the collection of PM10, PM2.5 or PM1 for subsequent analysis by PIXE. Ability to sequentially collect up to 168 hourly samples (1 week). Use of commercially available size-selective sampler inlets possible because system operates at a nominal flow rate of 16.7 L min−1 | 253 |
| APM | Air | Performance evaluation of respirable parallel particle impactor (PPI) samplers | PPI samplers challenged with polydisperse NaCl particles and select sizes of PSL particles with MMAD of 1–25 µm in laboratory chamber studies. D50 values of ∼4 µm determined for the single-use 2, 4 and 8 L min−1 flow rate PPI variants. D50 values of 4.07 µm determined for the reusable 2 L min−1 model but a value of 4.27 µm noted for the 4 and 8 L min−1 reusable variants | 254 |
| APM/asbestos fibres | Air | Development of a new portable water-based condensation aerosol concentrator | A turbulent-mixing condensation aerosol concentrator (TCAC) to efficiently collect aerosol/fibre samples by impaction onto a collection substrate as a small dried spot suitable for analysis. Demonstrated that for asbestos fibre counting applications using PCM, the TCAC could significantly reduce sample collection time (hence counting uncertainty) compared with conventional sampling onto 25-mm diameter filter collection by 2 and 3 orders of magnitude. Potential for device to be incorporated into small, handheld, portable instrument for the collection and subsequent analysis of nm µm−1-sized particles using laser spectroscopic methods, such as Raman, reflectance, absorption, fluorescence, or emission spectroscopy | 255 |
| CH4 | Air | Development of an improved portable air sampler for radiocarbon measurements | Improved sampler over earlier iteration developed allowing effective 14C measurements (MU of 0.9% for a 60 µg C sample) to be performed following collection of a 60 L air sample. Potential for direct coupling to AMS so avoiding use of an off-line collection trap | 256 |
| PM1 | Air | Development of improved PM1 size-selective sampler inlets | PM1 inlets based on the non-bouncing impactor (NBI) technique were developed that employed vacuum oil-wetted glass fibre filter (GFF) substrates, to minimise particle bounce, incorporating a daily vacuum oil injection facility. Operated at a nominal flow rate of 16.7 L min−1. Modified from the existing PM2.5 M-WINS inlet design with a cut-size (D50) of 0.99 ± 0.02 µm determined. Can be retrofitted onto existing air sampling platforms | 257 |
| PM1 | Air | Development of a combined inertial and pleated filter assembly for size-selective aerosol sampling | A filter-based PM1.0 sampling system, referred to as the inertial filter/pleated filter sampler (I/P sampler), developed to separate particles >1.0 µm from those of <1.0 µm but collect both size fractions. In field trials, good correlations were achieved between this I/P sampler and conventional PM1.0 air sampling devices (namely a cyclone sampler, a cascade impactor, a beta attenuation monitor and an EPA-approved federal reference method sampler) with r ranging from 0.90 to 1.07 (in summer time trials) and between 1.10 to 1.37 (in winter time trials) | 258 |
| PM1/2.5 | Air | Development of 3D printed micro-cyclonic samplers for low cost aerosol sampling applications | One-piece low-cost 3D-printed micro-cyclones (PM2.5 and PM1) fabricated for potential use in a range of aerosol applications. The collection efficiencies and 50% cutoff diameters (d50) of multiple cyclones evaluated with both monodisperse and polydisperse challenge aerosols which ranged between 0.1 to 3 µm in size. Altering the sampler inlet orientation relative to the micro-cyclone centreline (orthogonal, 50% offset, and fully offset) resulted in sharper cut-points being achieved | 259 |
| UFP | Air | Performance of four impactor devices for collecting UFP evaluated, namely an ELPI, a MOUDI, a PENS and an ultraMOUDI | Impactors designed to collect UFP evaluated in both laboratory and field trials with respect to parameters such as cutoff diameters, particle bounce, pressure drop and steepness of cutoff curve. All four designs were capable of separating and collecting UFP with a cutoff diameter of ∼100 nm but each offers unique advantages and limitations so it was essential to match an impactor to a specific application taking into consideration factors such as chemical composition, particle morphology and physical interaction of particles with selected impactor | 260 |
| Water | Fog/cloud | Development and evaluation of a new water collector for the analysis of cloud composition | New easy to clean sampler developed that can be used off-grid on battery power with a droplet D50 of 12 µm estimated via CFD. In 21 cloud collection trials, a water collection rate of 100 ± 53 mL h−1 determined with an estimated collection efficiency of 70 ± 11% | 261 |
Calibration of Hg analysers remains topical. The saturated mass concentration of Hg in air above a liquid pool can be calculated using the Dumarey equation and is used for calibrating gas analysers, but recent studies have questioned its accuracy. In a new study,17 the concentrations of Hg0 gas standards, generated either by cold vapour reduction of defined volumes and concentrations of NIST SRM 3133 (mercury standard solution) or prepared from a saturated headspace, were compared and differences of <4% noted. As the MUs overlapped, the researchers concluded that such small discrepancies were attributable to random measurement effects and not to any systematic bias. They also concluded that there was a need to correct Hg0 concentration values arising from air expansion effects during sample injection of aliquots of this head-space gas as calibrants. Page et al. described18 for the first time a methodology based on the use of on-line ID-ICP-MS for the direct quantification of gas standards generated from Hg calibrator units. This was achieved by: mixing the outputs from these calibrators with a vapour derived from the reduction of a 199Hg-enriched liquid standard, measuring the 202Hg/199Hg ratio of this blended gas and calculating the resultant calibrator output using a single ID equation adapted for gas mixtures. The efficiency of the 199Hg vapour generation step was predetermined via a procedure that used a 197Hg radiotracer. Significant uncertainties remain in the sampling and analysis of trace GOM species in ambient air, so a review19 (47 references) of current calibration approaches and future measurement requirements is timely.
Developments in RM applicable to air measurements are summarised in Table 2.
| Analyte | Sample matrix | Study rationale | Findings | References |
|---|---|---|---|---|
| Pu/U | MP RM | Development of a combined Pu/U RM for nuclear safeguarding measurement applications | New spherical particles 1 µm in size with desired elemental and isotopic distributions synthesised and electrostatically deposited upon silicon planchets | 262 |
| Hg | Pine needles | Development of two new RM for biomonitoring of atmospheric Hg concentration | NIES RM 1001 (pine needle 1) and RM 1002 (pine needle 2) with Hg values of 5.4 ± 0.4 and 22 ± 2 ng g−1 (k = 2) determined using TD-AAS. Indicative isotopic Hg values (via MC-ICP-MS) and selected elemental values (via ICP-AES/MS) also provided | 263 |
| Ni/Mo/W | Isotopic taggants | Synthesis and characterisation of isotopically barcoded taggants for intentional nuclear forensics applications | Synthesis of taggant species of Ni, Mo and W undertaken via a double-spike mechanism, whereby two highly enriched isotopes of interest per elemental taggant were mixed to form an enriched “double-spike” that was subsequently isotopically diluted with bulk material having a natural isotopic composition. 60Ni/58Ni, 100Mo/98Mo, 186 W/183W measurements undertaken via MC-ICP-MS at two independent laboratories |
264 |
| Various | Atmospheric fallout material | Further characterisation of a RM prepared by the National Meteorological Institute of Japan | The 237Np activity concentration, 237Np/239Pu atom ratio, and 237Np/241Am activity ratio in a reference fallout material determined following separation and purification using AEC, use of 242Pu as an ID tracer in subsequent assays using SF -ICP-MS | 265 |
Air-related sample preparation applications are summarised in Table 3.
| Analyte | Sample matrix | Study rationale | Findings | References |
|---|---|---|---|---|
| NPs | Air filter samples | Development of a standardised MAE procedure for extraction of non-labile metallic NPs prior to sp-ICP-MS analysis | Quantitative extraction of unaltered NPs e.g. Au/Pt NPs achieved in 6 min using a 0.1 M NaOH extractant | 266 |
| NPs | Urban dust | Methodology developed for the separation of metallic NPs from bulk dust samples and their preparation for subsequent biotoxicity testing | Isolation of NPs from dust matrix achieved using coiled tube FFF. Albumin then used as a stabilising agent, a 5 min UV treatment to sterilise samples (because extracted NP samples contained microorganisms) and a ultrafiltration step to preconcentrate samples | 267 |
| REEs | APM/cigar smoke samples | Synthesis of magnetic functional sorbents for SPE of REEs from digested samples prior to ICP-MS analysis | Sorbent demonstrated a high affinity for REEs (EF of up to 300) with good reusability (up to 45 times) and enabled MDL of 0.001–0.2 ng L−1 to be achieved | 268 |
| PM2.5 | Filter samples | Development of an UAE procedure for extraction of metals from PM2.5 samples, collected on beta attenuation filter spots, prior to ICP-MS analysis | Use of a HNO3 extractant enabled metals of regulatory interest such as As, Cd, Co, Cr, Cu, Ni, Pb, Sb, and V to be determined at MDL of 0.001 µg m−3 (24 m3 air volume sample). However, endogenous concentrations of elements, such as Ba, Fe and Zn present in the glass fibre filter media, compromised some measurements | 269 |
In a review25 (121 references) of progress in the use of LIBS for measurements of atmospheric species, selected applications were presented as exemplars. One example was the emerging use of LAMIS for isotopic analysis exploiting both atomic and molecular spectral emission data. A second example was the analysis of indoor air pollutants when algorithms and tools such as BP-ANN, PCA and SVM were leveraged to decipher emission signals arising from complex aerosol mixes. A third example was use of LIBS in wider industrial settings, such as monitoring workers’ exposure to welding fume or measuring emissions from biomass combustion, where on-line rapid measurements were advantageous for process diagnostic purposes. Future directions noted included use of ultrafast LIBS to enhance laser ablation efficiency and stability; use of LIBS-LIF to enhance measurements of organic species, and use of machine learning tools for improved data interrogation.
Air-related atomic spectrometric applications and developments are summarised in Table 4.
| Analyte | Sample matrix | Study rationale | Findings | References |
|---|---|---|---|---|
| Al, Ca, Fe, Si, Ti | Coal dust | Development of an on-line SES-based analyser for the determination of metals in coal dusts (anthracite, bituminous coals and lignite) | LOD of <4 mg m−3 for a sampling time of 10 min. Use of PCA possible to categorise coal samples | 270 |
| Al, Ba, Ca, Cu, K, Mg, Na | APM | Use of a commercially available PILS in conjunction with a micro discharge OES (µDOES®)analyser for near real-time determination of water-soluble metals in sampled µm-sized particles | LODs of 0.01 (Al), 0.02 (Ba), 0.01 (Ca), 0.01 (Cu), 0.01 (K), 0.05 (Mg) and 0.001 (Na) µg m−3 with long-term repeatability of <5% achieved. Suggested that the compact design with advantage of ease of operation and maintenance was suitable for in situ measurements in the field | 271 |
| Ba, Pb, Sb | GSR | Development of a protocol for the identification of GSR that used LIBS in conjunction with use of PCA and a probabilistic SVM algorithm for dimensionality reduction | Potential alternative to the more commonly used SEM-EDS method developed. Demonstrated that 100% accurate classifications were possible even in simulated samples contaminated with those elements characteristic of GSR | 272 |
| Cr2O3, CuO mixed with SiO2, Ni2O3, ZrO2 | Simulated workplace aerosols | Development of a real-time analyser that integrated Raman and SES to characterise both the elemental and molecular composition of airborne particles present in workplace air | Nozzle impactor-based sampler developed to collect and preconcentrate aerosol samples for analysis. Instrumental LODs were 80 (Cu), 14 (Cr), 6 (Ni) 14 (Si) and 65 (Zr) µg m−3 for a nominal 20 L air sample collected at 2 L min−1 for 10 min | 273 |
| Cu, Pb | Simulated aerosols | Development of a LIBS analyser for in situ analysis of gas-phase aerosols contaminated with metals | System consisted of a 1065 nm Nd; YAG laser, a Czerny–Turner spectrometer and a CCD camera. Simulated Cu and Pb aerosols over the range 0.26–1.29 ppmv and 0.40–1.19 ppmv generated from nebulising liquids standards that were subsequently desolvated. The instrumental LODs were 2 and 5 ppbv with LOQs of 5 and 28 ppbv | 274 |
| Hg | Flue gas | Development of an APGD-AES spectrometer, incorporating a gold amalgam system for analyte enrichment for the ultrasensitive determination of Hg | Measurements at 253.6 nm performed. The method LOD was 0.1 µg m−3 for a nominal 10 L gas sample. Relative deviations from reference measurements undertaken using a Hg combustion AAS analyser were <3% | 275 |
| Hg | Air | AFS analysers require the use of inert carrier gases such as Ar or He but ongoing replenishment of bottled gas supplies was logistically challenging for analysers deployed in remoted monitoring locations so development of an analyser with reduced gas consumption undertaken | New prototype AFS analyser developed which incorporated a recirculating carrier gas system with an embedded Hg scrubber so facilitating reuse. Gas consumption was only 1 L per week, up to 99% decrease in gas consumption compared with that of existing analysers | 276 |
| K, Na, Mg | Simulant aerosols | Development of a field deployable LIBS instrument for the analysis and classification of aerosol particles at the single particle level | A size amplification aerosol charging device employed for efficient particle focusing using a linear electrodynamic quadrupole. Absolute instrumental LODs achieved on stimulants were 70 (K), 40 (Na) and 2 (Mg) ng. In testing of an outdoor aerosol sample with particles in the size range of 1–3 µm, an analysis speed of ca. 20 particles per min. and size LODs of 0.3–0.8 µm were achieved | 277 |
| O2 | Ice core bubbles | Development of a new instrument, based on the optical-feedback cavity-enhanced absorption spectroscopy (OF-CEAS) technique for the simultaneous and continuous measurement of O2 concentration and δ18O(O2) in trapped gas bubbles at high-temporal-resolution to better understand past climatic conditions | The minimum Allan deviation occurred between a 10 and 20 min window, which corresponded to the optimal achievable integration time and analytical precision, —0.002% for the O2 concentration and 0.06‰ for δ18O(O2)—before onset of instrumental drift started to degrade measurements. Results on test gas samples were in good agreement with those obtained using dual-inlet IRMS. Measurements of δ17O(O2) values were possible but achievable precisions as yet not comparable to those obtained using IRMS | 278 |
| Rh, Pd, Pt | Spend automotive catalyst and e-waste materials | Development of a method for the determination of PGE using HR-CS-FAAS following MAE at 240 °C using aqua regia | LODs of 0.6, 0.5 and 0.4, mg kg−1 achieved for Pd, Pt and Rh, respectively with a precision <7%. Results for Pd, Pt and Rh in ERM EB504 (PGE in used automobile catalyst) respectively and Pd in BAM CRM-M505a (electronic scrap) were within certified ranges | 279 |
Handling and interrogating large datasets remains challenging, so a review of the advances here in single cell/particle-ICP-(TOF)-MS studies28 (45 references) is welcomed. A new iteration of SPCal, an open-source Python-based programme initially developed to handle QMS datasets, has now been released29 for sp-TOF-ICP-MS users. New tools were incorporated to facilitate the handling and manipulation of larger data at processing rates >1 and 2 gigabit min together with implementation of enhanced data analytical tools and improved statistical functionalities. Deciphering complex and overlapping particle signal events in sp-ICP-MS studies can be difficult, thus making particle-type classification studies challenging. To assist here, a multi-stage SSML model was developed30 which used as a training sample, a suspension that consisted of natural biotite, ilmenite and rutile NPs alongside a man-made TiO2 NPs (E171 grade) material. Improved classifications were thus obtained with false positive classification rates of <2% for the natural species and <5% for the anthropogenic material. It was suggested that use of this SSML model approach could be extrapolated to other particle classification studies.
Effective sample preparation is key to good analysis. In developing31 a sp-ICP-MS method for the determination of airborne metallic NPs in indoor air, use of MCE filter media for sampling was advantageous, because the particles were fully dissolved in 0.1 M NaOH by MAE. This enabled various test NPs to be quantitatively recovered from spiked test samples irrespective of composition or size. In subsequent experiments using Pt NPs, a LODsize of 15 nm and a LODconcentration of 120 particles L−1 were established, values deemed suitable for future indoor air quality measurements. Following preliminary UAE experiments that involved leaching aliquots of ERM-CZ120 (PM10-like fine dust) in different extractants,32 10 mM Na4P2O7 solution was deemed optimal. In subsequent sp-ICP-MS analysis of extracts from PM10 air filter samples collected in the vicinity of a historical mining area, it was determined that 0.3–1.7% of total Pb and 0.6–3.8% of total Zn were NPs.
Use of a novel on-line gaseous sample introduction system enabled metal(loid) impurities, be they gaseous or nanoparticulate, in semiconductor grade gases to be determined33 by ICP-MS. The gas exchange device (GED) incorporated a membrane for the effective substitution of the test gas matrix with argon thus enabling the plasma to be sustained. Achievable elemental LOD were typically 5 to 50-fold lower than those obtainable using a conventional gas-into-liquid impinger sampler with ICP-MS analysis back in the laboratory. A similar GED-ICP-MS system was deployed34 in the on-line determination of trace metals in PM1.0 where the average concentrations of metals (Ba, Cd, Co, Cr, Cu, Mn, Mo. Ni, Pb and V) were <10 ng m−3. The high temporal resolution of this methodology effectively captured diurnal variations and episodic pollution events, which was not possible with traditional time-averaged filter-based methods that involved laboratory analysis. Preliminary results were reported35 in a novel study suggesting that ICP-MS/MS could be used to identify organic-based volatiles. Initially, test VOCs such as benzene and toluene were introduced directly into the CRC resulting in molecular interactions induced by collision with Ar+ ions derived from the plasma. From examination of resultant mass spectra the reaction products observed, arising from a soft ionisation process, included molecular ions (M+), protonated ions ((M + H+)) and deprotonated ions ((M–H)+). A follow-up investigation of volatile dimethyl diselenide (Se2(CH3)2), revealed products such as Se+, Se2+, [SeCH3]+, [Se2CH3]+, [Se2(CH3)2]+ and SeH+ indicating that other processes occurred besides soft ionisation.
Other ICP-MS applications and developments for air-related measurements are summarised in Table 5.
| Analyte | Sample matrix | Sample preparation/introduction | Technique | Rationale and findings | References |
|---|---|---|---|---|---|
| Ag | NP test standards | Miniaturized ultrasonic nebulization | sp-ICP-MS | Development of a miniaturized ultrasonic nebulization system that achieved ∼80% transport efficiency thereby enabling AgNPs of 60 nm and 100 nm to be accurately sized | 67 |
| Au | Spiked polymer thin film | LA | sp-ICP-MS | Liquid-spiked polymer thin films standards produced that enabled defined number of particles to be introduced into the plasma by selecting a particular laser ablation spot size. Accurate sizing of both single- and multi-element NPs within ≤2.5% of the certified diameter value achieved. A LODmass for gold NP of 3 × 10−7 ng achieved, which equated to a LODsize of 15.5 nm, comparable to that obtained with the more conventional liquid-suspension sample introduction approach | 280 |
| Au, Fe | NP standards | Direct particle introduction and suspension nebulisation | sp-ICP-MS | Direct surface sampling probe system developed with an extraction efficiency of 4–10% comparable to the transport efficiency (1–10%) obtained with conventional liquid-suspension sp-ICP-MS introduction. NPs and MPs ranging from 30 nm and 1 µm accurately sized | 281 |
| Ce, Eu, Lu | Lanthanide doped test microparticles | Suspension nebulisation | sp-ICP-TOF-MS | Performance (accuracy, impact of collision gas in CCT mode, precision, signal intensity) of two commercial instruments (icpTOF 2R® and CyTOF Helios®) for the determination of 153Eu/151Eu, 142Ce/140Ce, and 176Lu/175Lu in lanthanide-doped MPs assessed as a prelude to future fingerprint studies for identifying sources and fate of MPs released into the environment | 61 |
| CeO | 1 µm-sized CeO test microparticles | Suspension nebulisation | sp-MC-ICP-MS | Demonstrated that by using fast integration times, as low as 50 ms, it was possible to undertake isotope ratio measurements in microparticles that were of sufficient precision and accuracy for potential future environmental and nuclear forensic applications | 63 |
| Cr, Fe | NPs emitted from additive manufacturing 3D printing process involving use of impregnated ABS and PA filament polymers. (acrylonitrile butadiene styrene and polylactic acid) | Sonication from filters/suspension nebulisation | sp-ICP-TOF-MS | Sampling chamber and filtration system designed to collect emitted particles from printing process. Metals such as Al, Cr, Fe, Ti, and Zr measured in emitted particles demonstrating that metal-containing aerosols were released during 3D printing | 282 |
| Cu, Fe, Ti, Zn | NPs deposited from vehicular emissions | Filtration of motorway liquid runoff and rainfall samples/suspension nebulisation | sp-ICP-MS | Determined that average particle per L of runoff water in descending order was Ti (4.8 × 108) > Fe (1.7 × 108) > Zn (9.0 × 107) > Cu (7.8 × 107) from a heavily trafficked urban motorway ∼1 00 000 vehicular movements per d. Except for Fe, runoff samples exhibited higher concentrations of Cu, Ti and Zn NPs compared with the rainfall samples collected nearby as comparators |
283 |
| Fe, Pt, Si | Iron nanotubes and platinum nanorods | Sonication/suspension nebulisation | sp-ICP-MS | Application demonstrated that it was possible to obtain accurate mass and dimensional estimations that aligned with results obtain from more conventional SEM and HR-TEM analysis | 284 |
| Fe, Ti, Zn | Road-dust NPs | Air dried, filtered and suspension nebulisation | sp-ICP-MS | The number concentration ranges determined, per mg of road dust, were Fe (3.8 × 106–8.4 × 108), Ti (2.3 × 106 – 1.4 × 108) and Zn (6.0 × 105 – 2.3 × 108). Higher number concentrations found in summer than in winter. Hotspots of Fe-containing NPs were more concentrated in industrial and traffic areas, Zn-containing NPs were mainly distributed in the central urban areas, while Ti-containing NPs were abundant in areas that received high rainfall | 285 |
| Pb | PM10 | MAD of air filter samples | ICP-MS-MS | Development of a high throughput ICP–MS/MS measurement protocol enabled Pb isotope ratio values in PM10 to be determined in the first UK nationwide survey. Values for 207Pb/206Pb ranged from 0.864 to 0.910 (average RSE of 0.68%) while 208Pb/206Pb values ranged from 2.08 to 2.187 (average RSE of 0.84%). The calibration method developed used NIST SRM 981 (common Pb isotopic standard) and was sufficiently precise to distinguish variations in isotope ratios between sampling locations and types of samples | 286 |
| Ru | Ru-containing test particles collected on aerosol deposition samplers | Particles subsampled from deposition sampler collection plates onto GSR tabs prior to LA raster analysis | LA- ICP-TOF-MS | Automated, high-throughput analysis of particles presented on GSR tabs undertaken. Confirmatory analysis undertaken using SEM-APA on same tab samples demonstrated that LA-ICP-TOF-MS approach was 100% successful in detecting sampled particles | 287 |
The aerosol chemical speciation monitor (ACSM), available either as a quadrupole or a TOF mass spectrometer, is widely used for real-time in situ measurements of APM, but since both possess only unit mass resolving power, ions with similar m/z, such as OH+v NH3+, which are of interest to aerosol scientists, cannot be resolved. This limitation was now addressed37 by the development of an improved instrument with a m/Δm of 2000 resulting in a LOD improvement from 0.200 to 0.008 µg m−3 in measuring NH3 concentrations. Another accrued benefit was the improved mass spectral separation at m/z 30 of the CH2O+ and NO+ species thereby facilitating an improved interrogation of particulate nitrate species derived from either inorganic or organic precursors. There is a growing concern about the potential health impact of airborne nanoplastics, so their potential measurement by on-line aerosol MS is welcomed. In a proof of concept study38 that involved measuring nano-sized PET particles, it was observed that resultant mass spectra were consistent with those obtained using Py-GC-MS, a technique currently used in an off-line mode for measuring airborne nanoplastics collected on filters. This suggested that similar thermal decomposition processes and ion fragmentation mechanisms were in play. Measurements undertaken of characteristic fragmentation ions at m/z 149 and 166 enabled LODs of 0.4 and 0.1 µg m−3 to be achieved. The expansion of air monitoring research networks in different global locations has resulted in the deployment of an increased number of ACSMs, so a better understanding of instrument-to-instrument variability was critical if regional data sets were to be compared. In one recent intercomparison, the comparative testing of six Q-ACSM instruments was undertaken39 both in laboratory and field settings. In the former exercise, instruments were challenged with inorganic NH4NO3 and NH4SO4 particles and various organic species such as levoglucosan, which is used as an atmospheric chemical tracer for biomass burning. In the latter field exercise, variabilities in measured atmospheric concentrations of species such as Cl−, NH4+ and SO42− were assessed. Findings from this exercise provided valuable insights into the respective calibration and operational procedures used and enabled new relative ionisation efficiency data to be tabulated.
:
EC mass ratios of 0.81 and 1.17 for freshly emitted and aged carbonaceous particles were also tabulated.
Brown carbon is that fraction of organic aerosols that can adsorb light in the short-visible and UV spectral ranges. One key emission source can be wildfires which now occur at an increased frequency due to climate change. The publication of an extensive review paper43 (124 references) is therefore timely wherein emission sources, optical properties and measurement approaches were discussed. A key future requirement noted was the need to identify suitable chromophores that can be used as specific markers of brown carbon aerosols prior to the development of develop standardised optically-based measurement methods.
Elemental carbon (EC) is determined via combustion analysis of APM collected on air filter samples using thermal optical analysers (TOA) working to operationally-defined protocols. Subtle alterations in protocols employed in laboratories can result in variations in reported EC values and here use of ILCs were valuable in gaining a better insight into such differences. In one reported single study,44 an expanded (k = 2) MU of 17% was calculated for determinations of EC collected on filters from the exhaust of a helicopter engine by five participating laboratories operating identical analysers and protocols. Here test samples were prepared by passing emissions initially through a catalytic stripper to remove volatiles and collecting a PM1 fraction on filters for comparative testing. It was noted that while this MU value was largely dominated by the between-laboratory variance which likely represents the optimal achievable method performance because identical instruments working to the same protocol were used. In a second study45 that involved laboratories participating in an ongoing PT programme for the analysis of diesel fume collected on filter samples, a median between laboratory reproducibility of 23% and 19% was calculated for those cohorts that operated the widely-used EN 16909 and NIOSH 5040 protocols, respectively. Furthermore, the correlation coefficient between ECNIOSH 5040 data and ECEN16909 data was 0.86, which agreed well with those of previously published relationships.
The environmental burden of nano- and microplastics has become a growing concern in recent years, leading to a significant increase in research interest and scientific publications in this field. Three comprehensive reviews provided an oversight of current developments. Fernandes et al.47 (154 references) focused on the characterization of microplastic in aquatic environments. Moteallemi et al.48 (233 references) concentrated on analytical methods and removal strategies for microplastic in water systems. Vasudeva et al.49 (265 references) explored spectroscopic techniques and offered insights into metal adsorption on nano-/microplastics. Each review highlights a distinct aspect of microplastic research, underscoring the multifaceted nature of this environmental issue, the complexities involved in detecting such analytes, and the analytical challenges.
Environmental contaminants are becoming increasingly diverse, requiring analytical techniques to evolve accordingly. One promising approach to extract more comprehensive information from a single sample is the use of multimodal chemical speciation techniques. Kato et al.50 (104 references) published a detailed tutorial review, serving as an introductory guide to this emerging field, that focused on the simultaneous application of high-resolution molecular and atomic MS for both target and non-target analytes. The review outlined the principles, strengths, and limitations of various MS techniques and discussed strategies for optimizing split-stream detection setups following chromatographic separation. The potential of this approach was illustrated through a case study involving turtle liver, and the authors also presented advanced data evaluation strategies to support broader adoption in environmental, biological, and pharmaceutical research.
Reference materials are essential to support analysts in regulatory contexts by providing a basis for reliable and comparable data. This need is particularly evident with the increasing demand to quantify nanomaterials in the aquatic environment based on particle number, which calls for the development of number-based standards. Addressing this gap LGCQC5050, a number-based RM consisting of 30 nm colloidal gold NPs suspended in deionized water specifically designed for use in sp-ICP-MS, was developed.52 In addition to characterizing the material using the dynamic mass flow method with sp-ICP-MS, the authors shared their experiences with the production, storage, and transportation of nano RMs, providing guidance for future developments in compliance with ISO 17034.
| Analytes | Matrix | Technique | Substrate | Coating or modifier | LOD in µg L−1 (unless stated otherwise) | Method validation | References |
|---|---|---|---|---|---|---|---|
| AgI, PdII | Tap, river, waste, sea and mining water, soil | FAAS | SiO2/MMWCNT | 8-HQ–HCHO–TU polymer | 0.2 (Ag), 0.5 (Pd) | 206 BG 326 (ore polymetallic gold Zidarovo-PMZrZ) | 288 |
| AsIII | Tap, river, waste and well water | ICP-AES | Glycidyl methacrylate modified magnetic NPs | Cystamine dihydrochloride | 0.050 | GBW08666 (arsenious acid solution), GBW08667 (arsenic acid solution) | 289 |
| AsIII, AsV, DMA, MMA | Tap, bottled and geothermal water, urine | LC-ICP-MS | agarose fibers | FeNP | 0.10 (AsIII), 0.25 (AsV), 0.01 (DMA), 0.37 (MMA) | NIST SRM 2669 (arsenic species in frozen human urine), NIST SRM 1643a (trace elements in natural water) | 290 |
| AsV | Fortified water | EDXRF | Amino functionalized Zr-based metal organic framework (UiO-66-NH2) on carbon cloth | — | 0.790 | Spike recovery (water) | 291 |
| AuIII, PdII | Tap, river and sea water | FAAS | Silica gel | N-((6-(2-thienyl)pyridin-2-yl)methyl)propan-1-amine | 0.038 (Au), (1.04) Pd | Spike recovery (water) | 292 |
| Bi | Tap and spring water | FAAS | Ni(OH)2 nanoflowers | — | 2.8 | NIST SRM 1643f (trace elements in fresh water) | 293 |
| CdII | Tap, mineral, river, sea water and vegetables | FAAS | Benzophenone | — | 0.4 | NIST SRM 1643d (trace elements in water) | 294 |
| CdII | Tap, farming, water, food samples | FAAS | Magnetic Cu2O nanocubes | — | 0.12 | IRMM CRM BCR 505 (estuarine water (trace elements)), NIST SRM; 1577b (bovine liver) | 295 |
| CdII | Tap and waste water, tobacco, food samples | FAAS | MWCNT@TiSiO4 | — | 0.053 | NACIS CRM NCS ZC 73033 (scallion), NIST 1570a (spinach leaves), IRMM CRM BCR-505 (estuarine water (trace elements)) | 296 |
| CdII, CoII, NiII, PbII, ZnII | Tap and bottled water, milk, juice | FAAS | Silica gel | (E)-N′((2-butyl-4-chloro-1H-imidazole-5-yl)methylene)isonicotinohydrazide | 1.48 (Co), 2.97 (Cd), 3.17 (Ni), 1.62 (Pb), 1.55 (Zn) | Spike recovery (water) | 297 |
| CdII, PbII | Sea, bottled, tap and mineral water | FAAS | ZnO NPs | Fe3O4 | 7.86 (Cd), 2.36 (Pb) | Spike recovery (water) | 298 |
| Cd, Co, Cu, Ni, Pb | Water, Chinese herbal medicine | ICP-MS | Thione and amine groups-rich magnetic COF | — | 0.00026 (Cu), 0.00016 (Cd), 0.00025 (Pb), 0.00008 (Co), 0.00017 (Ni) | Spike recovery (water) | 299 |
| Cd, Cu, Ni, Pb, Zn | River, tap and high salt matrix simulated water | SCGD-AES | DIAION™ CR20 | — | 0.6 (Cd), 0.6 (Cu), 2 (Ni), 6 (Pb):, 2 (Zn) | GBW08608 (metal elements (Cd, Cr, Cu, Ni, Pb and Zn) in water) | 300 |
| Co, Cu, Ni, Pb | Dam, river and lake water, industrial effluent | FAAS | Fe3O4 NPs | Carboxymethyl-β-cyclodextrin | 0.14 (Co), 0.55 (Cu), 0.5 (Ni), 1.38 (Pb) | ECCC CRM TMDA 64.3 (a trace metal fortified sample, lake water) | 301 |
| CrIII | Tap, mineral and waste water | FAAS | Acid activated perlite | Pichia kudriavzevii (JD2) | 4.8 | RM SPS-WW1 (waste water) | 302 |
| CrVI | Tap and deionized water | ICP-AES | Polyurethane foam | Sol–gel-functionalized | Not calculated | Spike recovery (water) | 303 |
| CuII | Waste and tap water, tea | FAAS | MnSb2O6 NPs | Fe3O4 | 2.1 | Spike recovery (water) | 304 |
| CuII | River, tap and waste water, food samples | FAAS | MnO2 nanowires | — | 2.9 | IRMM CRM BCR-505 (estuarine water (trace elements)), NIST SRM 1573a (tomato leaf) | 305 |
| PbII | Tap and river water, food samples | GFAAS | CuII-nanocluster | Folic acid-capped | 0.014 | Spike recovery (water), NIST SRM 1515 (apple leaves) | 306 |
| PbII | River water, food samples | GFAAS | TU@MOF-199 | — | 0.0005 | Spike recovery (water) | 307 |
| SeIV | Tap, river, mineral, spring and waste water | UPLC-DAD | MIL−125−NH2 MOF | — | 0.013 | Spike recovery (water) | 308 |
| TlI | Tap, spring, river and sea water | EDXRF | Sepolite nanomaterial | Prussian blue | 0.057 | Spike recovery (water) | 309 |
| U | Ground, river, tap and lake water | ICP-MS | C18-Disc | 1-(-2-Thiazolylazo)-2-naphthol | 1.5 | ECCC CRM TMDA-52.4 (a trace metal fortified sample, lake water) | 310 |
| Volatile metal organics (As, Hg, I, Sn, Sb) | Waste water | TD-MIP-AES | Stableflex 85 µm | — | 0.016 (Bu3SnCl), 0.025 (SbH3), 0.0067 (MeHgCl), 0.0052 (Hg0) | IRMM CRM ERM-CA 011a (hard drinking water), IRMM CRM ERM CC580 (estuarine sediment) | 311 |
| Zn | Environmental water, food samples | ICP-AES | NiO nanoflower | — | 0.77 | NIST SRM 1573a (tomato leaves), spike recovery (environmental water, waste water) | 312 |
| Zn | Tap water | EDXRF | Fe3O4 NP | 1-(2-Pyridylazo)-2-naphthol | 450 | Spike recovery (water) | 313 |
| Analytes | Matrix | Technique | Method | Reagents | LOD in µg L−1 (unless stated otherwise) | Method validation | References |
|---|---|---|---|---|---|---|---|
| Al (bioavailable) | River and lake water | ETAAS | VALLME | Salicylaldehyde 4-picolinhydrazone and sodium dodecyl sulfate | 0.015 | Spike recovery | 314 |
| Au | Water, sediment, acid and ornaments | FAAS | DLLME | Bis (salicylaldehyde)ethylenediimine, NaNO3, CHCl3, and ACN | 1 | Spike recovery | 315 |
| CdII | Tap, bottled, pond and waste water | FAAS | LLME | Tetra-n-butylammonium bromide and decanoic acid | 0.7 | SPS RM WW2 (waste water level 2) | 105 |
| CdII, NiII | Waste and mineral water, food samples | FAAS | DLLME | DES-based ferrofluid | 15 | Spike recovery | 316 |
| Co | River water | ETAAS | DLLME | 2-(5-Bromo-2-pyridylazo)-5-dimethylaminobenzen-amine, 1-hexyl-3-methylimidazoIium hexafluorophosphate, and ACN | 0.026 | Spike recovery | 317 |
| Cu | Tap water, tea | FAAS | LPME | Diphenylcarbazide in EtOH and 1,2-dichloroethane | 1.6 | Spike recovery | 318 |
| HgII | Tap water | Fluorescence Spectrophotometer | VALLE | Chloroform, 2,2′-bipyridyl and Rose Bengal | 6.06 × 10−9 M | Spike recovery | 319 |
| Pb | Drinking water | ETAAS | SFODME | 1-Hexyl-3-methylimidazolium hexafluorophosphate and 1-dodecanol | 0.075 | NRCC CRM AQUA-1 (drinking water certified reference material for trace metals and other constituents) | 320 |
| ThIV | Sea, ground, lake and river water | TXRF | CPE | Bis(phosphoramidate) and sodium dodecyl sulfate | 0.1 | Spike recovery | 321 |
| Tl | Mineral and river water | FAAS | LPME | Ammonium pyrrolidine dithiocarbamate and diisobutyl ketone | 2.1 | NIST SRM 1643e (trace elements in water) and SRM 2704 (buffalo river sediment) | 322 |
| ZrIV | Tap, ground and waste water, rock samples | ICP-AES | CPE | CTAB, Eriochrome cyanine R and Triton X-114 | 0.5 | Spike recovery | 323 |
The speciation of trace elements by HPLC-ICP-MS remains an important topic. Antimony is released into the environment through various natural and anthropogenic activities. Due to its four different oxidation states, each with distinct behaviours and toxicities, speciation plays a key role in understanding its environmental pathways and assessing its toxicity. Chen and co-workers56 developed a HPLC-HG-MC-ICP-MS method that enabled the identification of Sb species and determination of their isotopic compositions, significantly enhancing the amount of information that could be extracted from a single sample. The precision of the method was improved by using the linear regression slope method and In as external standard correction, reaching a precision <0.05‰ (2 s). The method was validated against synthetic solutions and CRMs NIST SRM 3102a (antimony standard solution), IGGE GSD-11 (stream sediment) and GSD-12 (stream sediment) as well as applied to different types of environmental water. Tellurium is another element that occurs naturally at low concentrations but due to anthropogenic activities, its presence in the environment is increasing. Given that toxicity is dependent on its oxidation state, speciation of Te has become increasingly important. In this context, an HPLC–ICP-MS method using a reversed-phase C18 column was developed57 for the determination of TeIV and TeVI. The optimized method achieved LODs of 1.4 ng g−1 for TeIV and 0.5 ng g−1 for TeVI. Calibration was performed using NMIJ CRM 3630-a (Te standard solution Te(1000)) as the source of TeIV, while an in-house standard was used for TeVI. The method was then applied to river water and various seawater samples. One of the most widely investigated species systems in the aquatic environment is the CrIII/CrVI system, but many approaches are not thoroughly validated. Pechancová et al.58 employed a bottom-up approach to evaluate MU in characterizing and validating their IEC-ICP-MS method for Cr speciation in natural waters. The optimized, rapid method enabled separation within 1.5 min and achieved LODs of 0.98 µg L−1 for CrIII and 0.1 µg L−1 for CrVI. Comprehensive method validation was performed, including assessments of Cr species interconversion, quantification of uncertainty components, and verification of the developed MU model. Additionally, the method was validated for LOD, LOQ, trueness, repeatability, intermediate precision, selectivity, and carryover for both CrIII and CrVI using isotopically enriched CRMs. This results in a fully characterized and robust analytical method, an increasingly rare achievement in the current scientific literature.
In recent years, a relatively new approach has gained increasing attention: the determination of isotopic ratios within micro- and nanoparticles, which could help trace the source of the particles in aquatic bodies and determine whether they are of anthropogenic or natural origin. In this regard, three different isotopic systems (153Eu/151Eu, 142Ce/140Ce, and 176Lu/175Lu) were investigated61 in commonly used, commercially available PS calibration beads for CyTOF, using two different ICP-TOF-MS systems (CyTOF Helios and icpTOF 2R). This study found that the measured results closely matched the theoretical values, with the icpTOF 2R delivering slightly better performance. However, as the RSD for the icpTOF 2R measurements ranged from 6% to 19% for the investigated systems, and no correction of instrumental isotopic fractionation was applied, the results indicate that further research is necessary if precise isotopic ratios in the ‰ range or better are required. Manard et al.62 conducted a comparative study using both MC-ICP-MS and ICP-TOF-MS for the isotopic analysis of NdVO4 NPs (ca. 100 nm diameter). For the investigated isotopic systems, 142Nd/144Nd, 143Nd/144Nd, 145Nd/144Nd, 146Nd/144Nd, and 148Nd/144Nd, they reported relative differences ranging from −20% to 0.7% for the sp-ICP-TOF-MS system, and from −2.4% to 3.9% for sp-MC-ICP-MS, relative to bulk MC-ICP-MS measurements after digestion of the NPs. In both approaches, the RSDs of the isotopic ratios were within the higher percentage range (3–26% for the sp-ICP-TOF-MS approach and 6–23% for the sp-MC-ICP-MS approach). A further study investigated63142Ce/140Ce isotopes in CeO2 NPs using sp-MC-ICP-MS, aiming to optimize the procedure for improved precision and accuracy. The FC integration time (ranging from 50 to 500 ms) and various ratio calculation methods were evaluated. The optimized method led to a reduction in percent relative differences and RSDs, although the values remained within the low percent range. The results demonstrate the potential of sp-MC-ICP-MS for isotopic analysis at the single-particle level, but also indicate that, for isotopic systems showing variability in the low δ-range, further improvements are necessary to achieve the precision and accuracy required.
With the ever-growing field of detection of nano- and microparticles in the aquatic environment, the range of sample introduction systems used, and calibration strategies followed has significantly expanded. To provide the scientific community with an overview of the possibilities and limitations of various calibration approaches for sizing micro- and nanoparticles, Bazo et al.64 evaluated different intensity-based and time-based methodologies for sp-ICP-MS using AuNPs (20–70 nm) and SiO2NPs (100–1000 nm). The authors concluded that the highest accuracy was achieved with transport efficiency (TE) independent, intensity-based methods. A further study evaluated65 the TE dependency on the particle size using SiO2 particles ranging from 500 to 5000 nm and Au particles ranging from 60 to 1500 nm. A dramatic decrease in TE was reported once particle sizes exceeded approximately 700 to 800 nm highlighting the importance of determining TE using particles similar in size to the samples. A systematic study on various low-consumption sample introduction systems for their suitability and performance in sp-ICP-MS was conducted by Priede et al.66 In this study, various combinations of spray chambers (three different types) and nebulizers (four different types) were investigated. The results showed that the desired TE of 100% was not achieved with any nebulizer/spray chamber combination. The study reinforced that careful selection of particle standards is essential. Besides the commercially available nebulizer/spray chamber combinations the development67 of a novel miniaturized ultrasonic nebulization introduction system was reported. This system enables the determination of low particle concentrations, such as those found in surface waters, due to its high TE of approximately 80% when 60 nm and 100 nm Au NPs were used to evaluate its performance.
The determination of TOC is a key parameter in assessing water quality but most methods are laboratory based. To address this limitation, Liu et al.70 developed a microchip-based AES method in which the C signal from a liquid electrode discharge microplasma was measured. The method achieved a LOD of 0.15 mg L−1 and an RSD of 4%. Each measurement required only 43 µL of sample and was completed within one minute. Recoveries of spikes ranged from 97% to 102%. The optimized method was successfully applied to determine TOC in both river and seawater samples.
| Analytes | Matrix | Technique | Reagents | LOD in µg L−1 (unless stated otherwise) | Method validation | References |
|---|---|---|---|---|---|---|
| Hg | River, tap, well water | µAPD-AES | Formic acid (8% (m/m)) | 0.33 | Spike recovery | 324 |
| Rh | Lake and river water | ICP-MS | 10 M formic acid, 10 mg L−1 Cu, 5 mg L−1 Co, and 50 mM NaNO3 | 13 pg L−1 | NRCC CRM AQUA-1 (drinking water) and SLRS-6 (river water) | 325 |
| Br, Cl, I | Various | ICP-MS | Acetic acid (1% (v/v), 20 mg L−1 Cu | 0.0063 (Br), 4.2 (Cl), 0.0019 (I) | NIST SRM 1515 (apple leaves), NIST SRM 1549 (whole milk powder), NIST SRM 1632c (trace elements in coal (bituminous)), NRCC CRM DORM-5 (fish protein) | 123 |
Continuous monitoring of river water can uncover dynamic processes and enable rapid responses to changes in water quality. To achieve this, researchers from the Federal Institute for Hydrology in Koblenz73 have developed a method that facilitates the collection of time-resolved data with an hourly resolution, integrated into a continuous 24/7 monitoring workflow. They engineered a custom self-cleaning fraction collector rack compatible with a commercially available system, incorporating an automatic dilution and acidification unit following a cross-flow filtration stage. This setup enables the direct sampling and analysis of water from the Rhine River that flows next to the laboratory in Koblenz. The method was optimized for the monitoring of 56 elements. To ensure data quality, CRMs were analysed at defined intervals. Validation of the method was carried out using RMs such as Spectrapure Standards SPS-SW1 and SPS-SW2 (elements in surface waters), as well as ECCC CRMs NWTM-15.3 (water trace elements), NWTM-26.5 (trace elements in water), and NWTMDA-51.5 (fortified lake water). Additional off-line comparative measurements also confirmed the method’s accuracy.
New applications and reaction gases for ICP-MS/MS continue to emerge since its introduction in the early 2010s, reflecting the ongoing evolution of this technique. This is particularly beneficial for aquatic samples, where analyte concentrations are often low and measurements suffer from interferences. A cell gas tested for its suitability in ICP-MS/MS was benzene in helium.74 This proof-of-concept study demonstrated that benzene is a promising reaction gas for certain elements, such as S and Se, where it significantly enhances the performance by reducing the impact of spectral overlaps of the ICP-MS/MS system. Building on previous work reported in last year’s update,75 researchers from the Pacific Northwest National Laboratory76,77 investigated the suitability of NO as a cell gas for various elements. During these studies, they examined the impact of impurities in the NO gas and found that using purified NO led to an increased sensitivity. Additionally, the use of purified gas facilitated the use of higher flow rates, which further improved interference removal. These findings emphasized the critical importance of using high-purity gases in the reaction cell of an ICP-MS/MS instrument to minimise unwanted side reactions. In some cases, even gases rated as high-purity (e.g. 5N grade) may require further purification, as trace contaminants, such as water, can adversely affect analytical performance.
Another field that benefits from progress in ICP-MS/MS is the determination of isotopic ratios. While MC-ICP-MS is the gold standard for isotopic ratio measurements, MS/MS systems are being explored to make isotopic analysis more accessible. Schlieder et al.78 optimised an ICP-MS/MS method using O2 for the determination of the chlorine isotopic ratio. The method was validated using the NIST SRM 975a (isotopic standard for chlorine) in ultrapure water reaching an accuracy of 0.1%, a precision of 1% and a LOD of 3.4 ng g−1.
Isotope ratio determinations in seawater are one of the most challenging applications. Li et al.79 employed UNDBD VG for sample introduction with MC-ICP-MS to determine the 143Nd/144Nd isotopic ratio. They corrected for the mass-dependent fractionation by applying the exponential law using the 146Nd/144Nd ratio. With the optimized method, the 143Nd/144Nd isotopic ratio was determined at Nd concentrations as low as 0.5 µg L−1 using only 600 µL of sample, and thus the method requires only an enrichment factor of approx. 1000, given that typical Nd concentrations in seawater range from 0.38 to 2.55 ng L−1. To validate the method, two NIMC CRMs GSB 04-3258-2015 and GBW04440 (Nd isotopic standard solutions), were analysed. Application to real seawater samples further demonstrated the suitability of this approach for trace-level isotopic analysis in complex marine matrices.
While the approaches above required ablating samples from a solid substrate, Chen et al.84 developed a LIBS method for the direct determination of metals in water using a fs laser to significantly reduce the splashing and plasma quenching effects associated with ns lasers. The optimised method resulted in LODs in the ng L−1 range for Cr, Cu and Pb with RSDs <4% and r2 values >0.99, for calibrations ranging from 10–400 µg L−1, indicating potential for real-time monitoring of metal contamination in water. To avoid splashing effects in ns-LIBS, Xiong et al.85 generated a high-temperature plasma at a needle tip where the nebulised sample solution was effectively atomised, achieving LODs of 43 mg L−1 for Cu, 58 mg L−1 for Cr, and 51 mg L−1 for Mn. The authors emphasized that this system can be readily integrated into online monitoring setups for real-time measurements in the field.
A useful tutorial review94 (107 references) on methods for the assessment of PTE contamination in soils first covered sample preparation and extraction methods and then gave an overview of a variety of atomic spectrometry techniques (AFS, ETAAS, ICP-AES, ICP-MS, and use of a direct mercury analyser). Common risk assessment indices, such as the PLI and PERI, were also described.
The impact of metallic NPs in plants is a topic of increasing concern. Developments in the characterisation and determination of such particles over the past 20 years by techniques including AFM, CE-ICP-MS, FFF-ICP-MS, HPLC-ICP-MS, LA-ICP-MS, sp-ICP-MS, TEM/SEM, XANES and µXRFS were reviewed95 (125 references) and progress in the understanding of NP uptake, accumulation and toxicity summarised. The authors emphasised the need for better integration of quantitative and qualitative analysis with computer modelling and theoretical frameworks to improve knowledge of NP-plant interactions.
New stable isotope ratio values were reported98 for δ142/140Ce in 22 Chinese RM’s, nine of which were soils. Samples were digested in acid, purified using a single column separation, and analysed by MC-ICP-MS using SSB and Sm addition, where the 149Sm/147Sm ratio was used to correct the measured δ142/140Ce values. A novel three-step sequential chromatographic separation99 enabled multi-elemental isotopic analyses by MC-ICP-MS to be carried out on 57 RMs that included soils, sediments and plants. Values for δ60Ni in 44 materials, for δ65Cu in 24 materials and for δ66Zn in 17 materials were reported for the first time.
Contributions to extraction methods for soils and plants primarily considered the efficiency and optimisation of existing methods. Gürbüz100 studied the efficiency of the Mehlich-3 reagent, ammonium bicarbonate-DTPA, the modified Morgan reagent, acid ammonium acetate-EDTA, and water, for the determination of phytoavailable B, Ca, Cu, Fe, K, Mg, Mn, P, S and Zn in 130 neutral and alkaline soils, benchmarked against more widely-applied extractants such as ammonium acetate and DTPA. Correlations between concentrations were ranked by means of TOPSIS (technique for order of preference by similarity to ideal solution). This multi-criteria decision-making technique identified ammonium bicarbonate-DTPA as the most effective extractant. Lopez et al.101 optimised acid volume, temperature and extraction time using a Box Behnken experimental design for the MAE of Ca, Fe, K, Mg and Na in mushrooms prior to quantification by FAAS (Mg, Fe) and ICP-AES (Ca, K, Na). Optimised conditions for a 0.5 g sample were addition of 1 mL H2O2 + 5 mL HNO3, and extraction at 198 °C for 10 min. Relative measurement errors ranged from −4.5% (Na) to +7.3% (Mg) in RM INCT-TL-1 (tea leaves), precision was <10%, and LODs ranged from 0.005 mg L−1 (K) to 0.079 mg L−1 (Ca).
An UAE for multielement determination in lignocellulose was proposed102 as an alternative to the standard EN ISO 16967 MAD method which uses harsh conditions and reagents to digest this notoriously resistant matrix. Optimal conditions were an ultrasound frequency of 45 kHz, acoustic amplitude 70%, a temperature of 50 °C, extraction time 30 min, and 20 mL of 1 M H2SO4. No significant differences were observed between concentrations of Ca, K, Mg, Mn, Na, P, Sr, Zn determined in sugarcane bagasse, and eucalyptus and pine wood residue biomass under these milder extraction conditions compared to the standard method (Student’s t-test, 95% CI). However, extractions of Al, Ba, and Fe were poor.
Deep eutectic solvents continue to be explored as milder and greener alternatives to traditional reagents Zhang et al.103 prepared four DESs based on guanidine hydrochloride, fructose, glycerol, citric acid, proline and choline chloride, and used them for the MAE extraction of Se from rice for determination by ICP-MS. Component ratios were optimised based on density and viscosity measurements. Concentrations of Se extracted by two of the DESs – one composed of 34% guanidine hydrochloride, 21% fructose, 45% water, and the other composed of 30% choline chloride, 25% citric acid, 45% water – were significantly higher than MAD with HNO3 and H2O2. However, the number of samples tested was not specified and the DES extraction time was relatively long at 45 min. Ferreira et al.104 reported that the extraction efficiencies of DESs were dependent not only on DES composition, but also on the preparation method. Three DESs were each prepared by two different methods: stirring without heating, and rotary evaporation under reduced pressure. The preparation method was found to affect both the viscosity and the melting point of the solvents. When used for MAE, the extraction efficiency for As, Cd and Pb in plant material was also influenced by the preparation method, indicating a need for further studies on the influence of component interactions.
In methods for solid-phase extraction, Vaezi and Dalali106 proposed a vortex-assisted extraction using a zeolite imidazole framework adsorbent for the preconcentration of Cd and Co in soil and vegetables, prior to determination with FAAS. However, the analytes were adsorbed (and eluted) separately and, while interferences for a range of other ions were assessed, potential inference of Cd and Co on each other was not considered.
Chen et al.107 proposed a five-step sequential extraction and procedure for the determination of content and isotopic composition of B in soil. Readily soluble B was extracted following Sun et al.;108 carbonate-bound B was extracted with 1 M HAc–NaAc (8 mL), 4 h shaking, 30 min centrifugation; organically-bound B was extracted with 0.02 M CaCl2 -0.01 M mannitol solution (25 mL), 4 h shaking, and 30 min centrifugation; adsorbed-bound B was extracted with 0.1 M NH3OHCl–0.01 M HNO3 (25 mL), 4 h shaking, and 30 min centrifugation. Each step was repeated six times. Residual B was extracted with 5 mL HNO3 + 1 mL H2O2 + 1 mL HF, at 180 °C for 10 h. Extractants from each step were purified using boron-selective resins and isotopic composition was determined by MC-ICP-MS, expressed relative to that of NIST SRM 951 (H3BO3). Values of δ11B ranged from −31.9 to 25.8‰: readily soluble B had the most positive δ11B values (+1.3 to +25.8‰) but relatively low content while residual B had the lowest δ11B values (−31.9 to −24.5‰) and the highest B content. Despite the long processing time, the extraction is of potential interest for studying B cycling and isotopic behaviour.
Organic forms of Hg are of particular concern due to their biomagnification potential. However EtHg is often overestimated following propylation of samples for Hg speciation analysis due to the formation of EtHg artifacts. Wu et al.109 combined CuSO4–HNO3–CH2Cl2, to remove Hg2+ from the derivatisation solution (thereby reducing artifact formation) with propylation to allow accurate quantification of EtHg. The approach offered recoveries of between 81 and 86%, with artifact levels <LOD (1.98 × 10−4 ng g−1), and gave comparable results to those of online SPE-HPLC-ICP-MS (r2 = 0.99).
Other separation and preconcentration methods for the analysis of soils, plants or related materials, or those developed for other sample matrices that used soil or plant CRMs for validation, are summarised in Table 9.
| Analyte(s) | Matrix | Technique and extraction mode | Reagent(s) | Findings | LOD (µg L−1) | Validation | References |
|---|---|---|---|---|---|---|---|
| Cd | Plants (spinach, tea), water | FAAS temperature induced DSPE | Dithizone chelating agent (1 × 10−4 M), benzoic acid sorbent, ethanol eluent | Digestion 2 g sample, HNO3 + H2O2 (2 + 1). Extraction 40 mg sorbent, 50 °C, pH 6. Elution 1 mL | 0.3 | SRM NIST 1643d (trace elements in water), spike recovery (10 and 20 µg L−1) | 326 |
| Cd | Plants (leek, lettuce), water | FAAS ion pair solvent assisted DSPE | KI for CdI42− anion formation, alkyl dimethyl benzyl ammonium chloride (ADBAC) ion pairing surfactant cation, benzophenone sorbent in ethanol dispersion solvent, ethanol eluent | Digestion 2 g sample, HNO3 + H2O2 (2 + 1). Extraction 0.5 mL, 10% (w/v) KI, 0.6 mL ADBAC (1 M) for ion pair formation, 2% (w/v) benzophenone. Elution 1 mL | 0.4 | Spike recovery (10, 20 and 50 µg L−1 for water; 0.5 and 1 µg g−1 for leek and lettuce; SRM NIST 1643d (trace elements in water) | 294 |
| Co, Cu, Ni, Pb | Plants (cucumber, mint, tobacco leaves), water (dam, effluent, industrial, river) | FAAS VA magnetic SPE | Fe3O4@–carboxymethyl-β-cyclodextrin adsorbent, 2 M HNO3 eluent | Digestion 0.7 g sample, 10 mL HNO3, 95 °C (hotplate). Extraction 20 mg sorbent, pH 7, vortex 3 min. Elution 1 mL. Sorbent recycling up to 13 times | 0.14 (Co), 0.55 (Cu), 0.5 (Ni), 1.38 (Pb) | Spike recovery (0.7, 0.8 and 1 mg L−1); CRM ECCC TMDA 64.3 (supplemented water), CRM INCT-OBTL-5 (ornamental basma tobacco leaves) | 301 |
| Hg, Ni, Zn | Beverages, foods (beans, rice, nuts), fruits (banana, orange, strawberry), vegetables (onion, spinach), water | ICP-AES magnetic SPE | Agaricus augustus biosorbent loaded on γ-Fe2O3 MNP, 1 M HCl eluent | Digestion 1 g sample, 5 mL HNO3 + HCl (1 + 1) heated (hotplate) till dry, followed by 6 mL HNO3 + HCl + H2O2 (1 + 1 + 0.2) MAD. Extraction 75 mg biosorbent, pH 4. Elution 5 mL. Sorbent cycling up to 30 times | 0.02 (Hg), 0.01 (Ni), 0.02 (Zn) | Spike recovery (5 µg L−1), SRM NIST 1643e (simulated fresh water), RM SCP science EU-L-2 (wastewater), RM NWRI EC NWTM-15 (spiked-fortified water), CRMs NACIS NCS ZC73350 (poplar leaves) and NCS ZC73014 (tea leaves) | 327 |
| Ni, Pb | Baby milk, chicken, onion, parsley, potato, rice, tea, tobacco, tomatoes | ICP-AES SPE | Sparassis crispa-loaded hollow mesoporous nano-silica sorbent, 1 M HCl eluent | Digestion HNO3 + HCl + H2O2 (1 + 1 + 0.2) MAD. Extraction 100 mg biosorbent, pH 6. Elution 5 mL. Sorbent cycling up to 25 times | 0.019 (Ni), 0.033 (Pb) | CRMs NACIS NCS ZC 73014 (tea leaves) and NCS DC 73350 (poplar leaves), RM NWRI EC NWTM-15 (fortified water) | 328 |
Interest has continued in the use of HR-CS-AAS for multielement analysis. A HR–CS–ETAAS method was developed111 and successfully applied for the determination of trace Pb in Antarctic grass, lichen and moss, simultaneously with the lithogenic elements Al and Fe, the concentrations of which are required to estimate environmental Pb enrichment. A matrix modifier (1 g L−1 Pb + 0.6 g L−1 Mg(NO3)2) and a compromise temperature programme (Tpyrolysis 900 °C, Tatomisation 2500 °C) avoided loss of the relatively volatile Pb whilst ensuring efficient atomisation of the more refractory Al. Combining spectral lines with different sensitivities and measuring at different points within each line extended the linear working range to four orders of magnitude for Al. Relative bias for analysis of four plant CRMs was in the range 8 to 12%, – 4 to +5% and −5 to +7%, for Al, Fe and Pb, respectively. Other authors coupled112 CVG with HR-CS-QTAAS for the sequential determination of As, Bi, Hg and Sb, followed by Se and Te, in a variety of samples, including sediment and soil. It was necessary to measure the analytes in two groups because different pre-reduction conditions were required for each. Flushing the reaction cell (and atomiser) with Ar (6 L min−1 for 20–30 s) before introducing NaBH4 eliminated spectral interference from residual NOx and O2.
Direct solid sampling avoids lengthy sample digestion procedures in atomic spectrometry. A method for mercury speciation analysis by thermal release ETAAS achieved113 baseline resolution of CH3HgCl, HgCl2, HgS and HgSO4 with a sample furnace heating rate of 15 °C min−1 and an argon gas flow rate of 0.2 L min−1. Calibrants were prepared by diluting the Hg species mixture with aluminium oxide and the method was applied to samples from a mine tailings dump. Spike recoveries from the tailings samples were 98–104% for CH3HgCl, HgCl2 and HgS, but only 88% for HgSO4. A Cd–Hg analyser incorporated114 a programmable ETV unit, a dual catalytic pyrolysis furnace (to remove interferences such as soil organic matter), a gold amalgamator (for trapping of Hg), and miniature AAS spectrometer detectors for each analyte (based on FAAS for Cd and CVAAS for Hg). Addition of a matrix modifier (7 + 3 m/m NaCl + citric acid) improved sensitivity for Cd, allowing sub ng g−1 LODs to be achieved for both analytes. Results could be obtained for a 100 mg soil sample in as little as 3 min.
An alternative to analysing dry solid samples is to present them to the instrument in the form of a slurry. A slurry sample introduction system for ETAAS was described115 that incorporated closed, cooled vessels to prevent evaporation and contamination. Automated stirring stabilised suspensions without the need for addition of surfactant. Results for the determination of Cd in RM BAM-U110 (contaminated soil) suspended in water were stable over a 12 h run involving 184 measurements, with relative measurement errors of −8 to +23%.
Other aspects of ICP-MS have been reviewed. Xu et al.119 (71 references) described advances in ICP-MS for detection of endogenous substances in single cells, including plant tissues (in Chinese with an abstract in English). Laser ablation ICP-MS was amongst the techniques included in an overview (112 references) by Vats et al.120 of MS approaches for elemental or molecular imaging of plants, microbes and food. Duan et al.121 provided a very comprehensive review (402 references) of stable Zn isotopes as tracers in environmental geochemistry, including information on sample processing and δ66Zn measurement by MC-ICP-MS. Quantitative and isotopic determination of REEs and radionuclides by ICP-MS/MS was the topic of Zhu et al.122 (170 references) who covered articles published since the first commercial instrument was released in 2012. A key conclusion was that for measurement of actinides, it would be useful to extend the mass range of the second quadrupole to >300 AMU.
A PVG-ICP-MS method123 for the simultaneous determination of Br, Cl and I used a novel spray chamber with internal UV light source for irradiation of sample aerosol and addition of 1% (v/v) acetic acid + 20 mg L−1 Cu2+. Signal enhancements relative to conventional pneumatic nebulisation were 40-fold, 3-fold, and 30-fold, for Br, Cl and I, respectively, with corresponding LODs of 6.3 pg mL−1, 4.2 ng mL−1 and 1.9 pg mL−1. Results for the analysis of NIST SRM 1515 (apple leaves) agreed with certified or information values (Student’s t-test at 95% confidence).
Coupling LC with ICP-MS for speciation analysis continues to be of interest. Methods for the analysis of seaweed based on IC-ICP-MS were reported that could separate and quantify As species124 (AB, DMA, AsIII, MMA and AsV) and Pb species125 (Pb2+, trimethyl lead and triethyl lead). A dual HPLC-ICP-MS/ESI-MS procedure126 in which the column effluent was split and directed towards the elemental and molecular mass spectrometers in parallel was developed and applied to study As detoxification mechanisms in seedlings grown in As-spiked hydroponic media. Arseno-thiols and AsIII-phytochelatins were detected in roots of plants exposed to AsIII and AsV, and arseno-lipids in roots exposed to AsV. A method for Se speciation in rice127 took a similar approach to a procedure for soil analysis described in our previous Update: samples were extracted (in this case with Pronase E enzyme); extracts were filtered; then soluble Se species in the filtrate were separated and quantified by HPLC-ICP-MS, whilst Se NPs trapped on the membrane were quantified separately.
A comparison of different standards for the determination of lanthanides in tea by LA-ICP-MS recommended128197Au as IS over 13C, 103Rh, 115In or 205Tl. External calibrants prepared by drying different concentrations of a lanthanide solution onto filter papers gave better precision that those prepared by spiking and pelleting powdered leaves or cellulose powder, and LODs were lower (20 ng g−1 for Ce, 75 ng g−1 for La and 14 ng g−1 for Nd). Results obtained for the three analytes in mint tea were in not significantly different from those obtained by digestion and conventional ICP-MS analysis according to a t-test at 95% confidence. The other lanthanides were <LOQs and not reported.
The ability of MC-ICP-MS to perform accurate stable isotope ratio measurement provides valuable insight into the biogeochemical cycling of trace elements. However, sample pretreatment procedures must be carefully optimised to remove interferences, maximise analyte recovery, and avoid isotopic fractionation. Advances for Cd isotopic analysis included AEC procedures129 applicable to plants, rocks, seawater and soil samples that gave δ114Cd values in agreement with previously published literature values for a suit of CRMs, and a dry ashing method130 for analysis of materials with high organic matter content (LOI > 90%). In the latter method, samples were wrapped in a quartz microfibre filter membrane – which was later removed by HF digestion – to avoid losses in the muffle furnace. Results were not significantly different from those obtained with high-pressure bomb digestion (t-test, p = 0.98) for a suite of eight CRMs, including BCR-482 (lichen) and GSB-16 (spirulina). For Sb, a HG-MC-ICP-MS procedure131 that involved SSB and Cd doping gave δ123Sb value ranges for geological and environmental CRMs of low analyte content – including four soils and one plant – that overlapped (within uncertainty) previously published values.
New optimised ICP-MS/MS approaches included the use132 of CH4 as reaction gas to successfully overcome the numerous mass spectral interferences associated with the determination of S in soil and plant digests. The analyte was measured as CH2SH+ ion clusters in mass-shift mode at m/z 47 and 49. An investigation133 of multi-element analysis of the Brassica tumorous stem mustard, recommended cool plasma conditions (rf power 600 W) and 1.5 mL min−1 NH3 reaction gas for interference reduction in the determination of Al, Co, Cr, Cu, Fe, Mn, Mo, Ni, Pb, Sr and V, but hot plasma conditions (rf power 1600 W) and 0.3 mL min−1 O2 + 7.0 mL min−1 H2 in the determination of As, Cd, Hg, Se and Zn. The LODs for all elements were below 1 ng g−1 except for that of Se (4.8 ng g−1). Studies featuring the determination of actinides in soil by ICP-MS/MS included a comparison76 of commercial NO (99.5% purity) and specially purified NO (<100 ppt H2O) reaction gases. The latter was shown to give a three-fold improvement in sensitivity for Np and Pu, and also meant that higher gas flow rates could be used to eliminate U interference. Other researchers studied134 actinide reactivity with CO2, O2, and O2/He reaction gasses that led to development of a method suitable for measurement of 241Am/241Pu ratios in the presence of complex sample matrices. Both nuclides were determined in mass shift mode, with Am detected as 241Am16O+ at m/z 257 and Pu as 241Pu16O2+ at m/z 273, to avoid the analytes interfering with one another.
An interesting application of sp-ICP-MS provided the first direct evidence of the existence of naturally occurring Cd-based NPs in paddy soil. The extraction procedure,135 which was optimised by adding CdS-NPs to a Cd-free soil, involved shaking of 0.5 g samples with 20 mL of 20 mM tetrasodium pyrophosphate at 300 rpm for 3 h. This gave better recoveries (71%) than UAE. When applied to soil from six paddy fields in Guangdong, China, 17–50% of the Cd content was found to be in the form of NPs.
A study136 on the translocation of Se in plants used isotopically labelled 82Se NPs to avoid the polyatomic ion interferences suffered by the more abundant 78Se and 80Se. This improved the sp-ICP-MS S/N approximately 11-fold and decreased the size LOD from 90 to 40 nm. Following foliar application to Oryza sativa (rice plants) 82Se NPs were taken up, but largely remained in the leaves, with little translocation to other parts of the plant. Such information is important for the optimisation of biofortification programmes to address Se deficiency, which affects roughly 1 billion people worldwide.
Feldmann et al.137 advocated the use of ICP-MS in non-target screening analysis of environmental samples. They emphasised the technique’s potential contribution in three areas: the identification of chemicals of emerging concern; the quantification of compounds for which no reference standards exist; and the revealing of ‘hidden’ compounds i.e., those that would not be detected if only targeted analysis was applied.
A novel nanolitre spray chamber was developed138 for use with microwave plasma torch MS that allowed the concurrent measurement of Cr, Cu, Ni, Pb, Zn and three phthalate plasticisers (based on their predominant [M + H]+ molecular ions) in soil. Limits of detection of 0.16 to 0.57 µg L−1 for the PTE and 0.02 and 0.05 µg L−1 for the phthalates were achieved at a samples flow rate of just 5 µL min−1, with recoveries from a spiked soil digest of 91–106% and 89–97%, respectively. A group of researchers first investigated139 the determination of Sb by HG-MPT-MS, demonstrating the possibility of accurate isotope ratio measurement through optimisation of capillary and tube lens voltages to remove interference from 123Te. They then attempted140 the more challenging direct determination of hydride-forming elements in solid samples by MPT-MS. Soil samples were ground, sieved and pressed into tablets for analysis, and calibration was achieved with respect to matrix-matched standards (clean soil spiked with the analytes of interest). The approach showed promise – As, Bi, Pb and Sb were all visible in the mass spectrum of soil CRM GBW07405 – but further work is needed to achieve accurate quantitative analysis.
Efforts have continued to enhance signal intensity and thereby improve LODs in the LIBS analysis of soil. To this end, two groups of researchers mixed conductive additives with their samples. One145 compared KCl, KBr, graphite, TiO2 NPs and ZnO NPs. They found the greatest enhancement for Cd was obtained with addition of 25% graphite, giving LODs of 1.5 and 3.6 mg kg−1 for two different soils. The other146 studied NaCl and graphite. Best performance (LOD 26.1 mg kg−1) for the determination of Pb was obtained with addition of a mixture containing 10% NaCl + 20% graphite. An alternative approach147 involved the simultaneous application of a magnetic field (110 mT) and an electrical field (12 V) to the area occupied by the sample plasma. This combined approach increased spectral intensity for Al approximately two-fold, and for Fe approximately three-fold. Other workers proposed148 (in Chinese with an abstract in English) an electrochemical LIBS method in which Hg was accumulated by electrodeposition on a gold electrode surface for interrogation with the laser.
A LIBS method149 for determination of Cr, Cu and Pb in soil extracts used Au@SiO2 NPs deposited on a specially designed laser-etched zinc substrate to improve LODs to 0.32, 0.28 and 0.36 mg kg−1, respectively. This work highlights a fundamental issue hampering the wider adoption of LIBS in soil laboratories, which is a lack of connectivity and knowledge sharing between the scientists developing the spectroscopic methods and experienced soil analysts. For example, Guo et al.149 noted that “remarkably” different results were obtained for Pb and Cu using different extractants. The fact that different extractants will remove different amounts of trace elements from the same sample has been known in the soil science community for the better part of a century. They also reported having “developed the solid-liquid-solid transformation (SLST) method”. However, what they actually did was a conventional UAE in DPTA – a procedure that is commonly-used in soil laboratories for assessment of phytoavailability – and then dried an aliquot of their extract on a hotplate.
Confocal controlled LIBS was applied150 for the first time to determine Cd in soil. Real-time autofocusing at each data-acquisition point improved ablation consistency i.e. reduced variability in ablation crater depth and diameter, relative to conventional LIBS, thereby improving spectral stability. The LOD decreased from 80 to 49 mg kg−1. However, this is still some way above that required for routine environmental monitoring.
Single-shot LIBS for rapid nutrient monitoring in hydroponically grown plants was proposed.151 Quantification was not attempted, but it was shown that the signal obtained for Ca in lettuce leaf increased with Ca concentration in nutrient medium. The study also confirmed the uptake of Ag NPs from hydroponic solution into plants. Although much more work needs to be done, the prospect of using real-time LIBS data to adjust hydroponic nutrient composition and thereby optimise crop growth is worthy of further exploration.
Many LIBS articles were concerned principally with advances in data processing and modelling rather than sample pretreatment or spectroscopy. Notable examples featuring soil were a machine learning approach based on the SHapley Additive exPlanations algorithm for the prediction of soil C;152 a transfer learning approach (named TransLIBS) for the determination of total N;153 a PCA-generalised spectrum-extreme learning machine model for quantification of major elements (Al, Ca, Fe, Mg, Si and Ti);154 and a black slit-supported stand-off LIBS method combined with machine learning for measurement of available soil nutrients (B, Ca, Cu, Fe, K, Mg, Mn, N, P, S, Zn).155 For plants, a multi-chemometrics approach allowed the determination of N in coco-peat;156 a XGBoost transfer learning model based on rice husks improved Cd detection in rice grains;157 and a Wasserstein generative adversarial network revealed differences in the distribution of Ca, Fe, K, Mg, Mn and Na in leaves of rice plants under chromium stress, relative to those in unstressed plants.158
An extension of the above is proximal analysis in which LIBS measurements, either alone or in combination with results obtained by other analytical techniques, are processed to classify or predict some property of a sample, rather than to obtain analyte concentrations. Interesting examples included a handheld LIBS method159 for prediction of soil organic carbon content and soil texture (proportions of sand, silt and clay); the integration of LIBS with convoluted neural networks160 to identify the origins of soybeans from different regions in China; and a classification system161 based on LIBS and machine learning that was able to distinguish different types of plant leaves.
A novel monochromatic excitation EDXRF system combined with fundamental parameters algorithmic analysis improved164 the detection of As and Pb in grain. Optimisation of the doubly curved crystal structure and the geometry layout resulted in improved sensitivity compared to that of existing EDXRF methods. The LODs of 0.02 mg kg−1 (As) and 0.03 mg kg−1 (Pb) were sufficiently low to detect these PTE at concentrations below food safety limits.
The influence of soil matrix variability on accuracy was considered in several studies. Wang et al.165 determined that linear relationships were particularly poor (r2 < 0.2) between concentrations of As, Cd, Cr, Cu, Hg, Ni, Pb and Zn, in grey fluvo-aquic, fluvo-aquic, purple and rice soils determined by ICP-MS and the net area of XRF characteristic peaks. Pearson’s correlation analysis indicated that the most significant parameters influencing accuracy were Fe, Mn, Si and organic matter contents. To compensate for errors arising from organic matter content, a correction was proposed166 using the Compton scattering peak as the internal standard. Application of the correction to As and Pb determinations in 33 soil samples, with organic matter content ranging from 0–49.5%, led to a reduction in relative measurement errors from 0.25–9.05% to 0.22–3.87% for As and 2.77–46.2% to 0.05–3.94% for Pb.
Studies on the performance of portable instrumentation and software included that of Purwadi et al.167 They compared the concentrations of a range of elements in plants obtained using three portable XRF instruments, and three different quantification methods. Instrument performance varied depending on factors including anode and filter type, element of interest and instrument settings. Quantification based on manufacturer’s algorithms were found to overestimate elemental concentrations and resulted in highest deviation from results obtained by ICP-AES, while empirical calibration based on XRF vs. ICP-AES regression had closest mean concentration agreement between the two techniques but occasionally produced negative results. Independent GeoPIXE software based on fundamental parameters gave the most accurate results, reducing errors by up to 95% compared to the manufacturer’s algorithms. Such variation in performance reinforces the need for due diligence when using pXRF spectrometry.
A review with 212 references studied169 analytical techniques for nanomaterial–mineral associations. Testing at the bulk, micro-, and nanoscale were discussed, alongside use of automated search software and preparation methods such as focused ion beam, ultramicrotomy, and ion milling. Studies that investigated the role of nanomaterials in soil organic matter stability and pollutant interactions were then considered.
000 documents revealed temporal and thematic trends, showing the evolution from ore geology and petrogenesis to broader applications supported by ISO standards and consolidated by the geoanalytical community. While RMs remain largely used in petrogenesis, CRMs are now more evenly distributed across earth, environmental, and chemical sciences. Current themes include high-resolution and microanalytical techniques, unconventional isotope systems, and the development of more realistic CRMs, with increasing attention to biogeochemical hazards, REEs, and radionuclides.
Recreating geological processes, but on a shorter time scale aided the development of new RMs. Three HfO2-doped cassiterite RMs were prepared171 by sintering milled powders (d50 = 6.3 µm) under elevated temperature and pressure while maintaining the 176Hf/177Hf ratio in the dopant powder. A rapid method for hematite RM production for Fe isotope analysis via LA-MC-ICP-MS involved172 compaction of Fe2O3 NPs, previously blended with polyvinyl alcohol, followed by sintering at 1000 °C for 2 h to yield isotopically homogeneous pellets. This RM was stable, could be easily polished, and the procedure could be extended to the preparation of other RMs. Development of pyrite based RMs,173 sphalerite RMs174 and rutile RMs175 also used a sintering process. Further information on these materials can be found in Table 10.
| Analytes | Matrix | Technique | RM name | Comments | References |
|---|---|---|---|---|---|
| Ag, As, Au, Bi, Cd, Co, Cu, In, Mo, Ni, Pb, Pd, Pt, Rh, Sb, Se, Sn, Te, Zn | Synthetic pyrrhotite | LA-ICP-MS | Po-800–9 | High purity pyrrhotite (Fe/S molar ratio 0.92), reacted at 800 °C for 4 days. Eighteen trace elements added at 100 mg kg−1. Ground, pressed and annealed at 600, 800 and 1000 °C for 9 and 28 days; optimal homogeneity at 800 °C, 9 days (RSD < 5% at 80 µm spot). Embedded in epoxy and polished with diamond paste | 329 |
| Al, Ca, Cr, Co, Fe, Ga, Mg, Mn, Na, Ni, Sc, Si, Ti, V, Y, Zn | Orthopyroxene | LA-ICP-MS | BL-1 | Homogeneity (µm–mm scale) confirmed by WD-XRF, EPMA and LA-ICP-MS. Bulk analyses (WD-XRF, ICP-OES, solution-ICP-MS) agree with in situ microanalyses. Ca, Cr, Mn, Na, Ni, Ti, V > 100 mg kg−1 | 330 |
| 40Ar/39Ar dating | Muscovite | MS | ZMT04 | Laser step-heating and single-grain laser fusion prior to MS. Homogeneity at single-grain level. Minimum sample mass: 1 mg. K–Ar recommended age = 1804 ± 21 Ma (2 SD). 40Ar/39Ar age: 1772.2 ± 2.7 Ma (2 SD) | 331 |
| B isotopes | Ca-amphibole | LA-MC-ICP-MS | PRG, FIN | PRG: B 6.75 ± 1.10 µg g−1; δ11B = −16.58 ± 0.06‰. FIN: B 3.27 ± 0.68 µg g−1; δ11B = −5.90 ± 0.09‰. Good isotopic homogeneity. BHVO-2 G as bracketing standard; reproducibility: PRG ±2.86‰ (2 SD, N = 87), FIN ±3.96‰ (2 SD, N = 70) | 332 |
| B isotopes | Tourmaline | LA-MC-ICP-MS | TOUR1, TOUR4, TOUR5, TOUR6 | Recommended δ11B (2 SE): TOUR1 −11.26 ± 0.06‰; TOUR4 −13.31 ± 0.07‰; TOUR5 −8.88 ± 0.05‰; TOUR6 −8.57 ± 0.04‰ | 333 |
| B, multielemental determination | Tourmaline megacrysts | LA-MC-ICP-MS | MD-B66, IM-B232, BR-DG68 | MD-B66: δ11B = −7.74 ± 0.25‰ (2 SD, N = 251)—primary homogeneous RM. IM-B232, BR-DG68: secondary RMs. Solution MC-ICP-MS: MD-B66–7.71 ± 0.32‰ (N = 12); IM-B232–13.17 ± 0.62‰ (N = 8); BR-DG68–13.85 ± 0.32‰ (N = 12). BR-DG68 homogeneous in major (Al, B, Ca, Fe, Li, Mg, Mn, Na, Si, Ti) and trace elements (Be, K, Sc, V, Co, Zn, Ga, Sr, Sn, Pr, Nd, Sm, Eu, Pb) | 334 |
| B & Sr isotopes | Natural Tourmaline | LA-MC-ICP-MS | HGL-3 | From Huanggangliang-Hanzhuermiao Sn-polymetallic belt. Homogeneous in B and Sr at 33 µm and 90 µm. B 36 830–43 700 µg g−1; Sr 216–260 µg g−1; Rb/Sr < 0.0013. δ11B = −12.83 ± 0.38‰ (2 SD, n = 485); 87Sr/86Sr = 0.70835 ± 0.00019 (2 SD, n = 515). LA-MC-ICP-MS precision: 0.42‰ (B), 0.00019 (Sr). Agrees with TIMS |
335 |
| C isotopes | Basaltic glasses | SIMS | ETNA24, ETNA32, ETNA36 | CO2 by SHM-IRMS: 2300 ± 69; 3360 ± 180; 2026 ± 34 µg g−1. δ13C (SHM-IRMS): −14.3 ± 0.7; −12.1 ± 0.2; −10.2 ± 0.7‰. H2O (TCEA-IRMS): 2.86 ± 0.06%, 1.02 ± 0.06%, 2.30 ± 0.06%. δD (TCEA-IRMS): −135.7 ± 0.9; −103.9 ± 0.9; −101.6 ± 0.9‰ | 223 |
| C isotopes | Silicate glasses | SIMS | 31 RMs | Glass series (MORB, basanite, NBO; andesite–basalt). Homogeneous δ13C. IMF reproducibility ±1.0‰ for CO2 down to 1800 ± 200 ppm. Internal precision ±1.1‰ (min. ±0.3‰) at 10–20 µm. CO2: 380–12 000 ppm. δ13C: −28.1 ± 0.2 to −1.1 ± 0.2‰ (±1 SD). SIMS δ13C (IMF-corrected) agrees with EA-IRMS | 336 |
| Cu, Fe & S isotopes | Chalcopyrite | LA-MC-ICP-MS | IGGCcp-1 | Homogeneity validated through EPMA. SN-MC-ICP-MS data: δ65Cu 0.43 ± 0.05‰ (2S, N = 30); δ56FeIRMM-014 and δ57FeIRMM-014: 0.24 ± 0.04‰ (2S, N = 18) and −0.36 ± 0.09‰ (2S, N = 18), respectively δ34SVCDT (EA-IRMS): −0.28 ± 0.60‰ (2S, N = 10) | 337 |
| Fe isotopes | Hematite | LA-MC-ICP-MS | Sintered hematite | δ 56FeIRMM014 for the initial powder, sintered pellets, and unsintered pellets: 0.45 ± 0.04‰ (2SD, N = 20), 0.44 ± 0.04‰ (2SD, N = 21), and 0.45 ± 0.02‰ (2SD, n = 3), respectively | 172 |
| Fe isotopes | Magnetite | fs-LA-MC-ICP-MS | HGS-9, FP-200, SX-72, CBL-500, SJS-20 | Isotopic homogeneity. δ56Fe precision: ±0.05–0.06‰ (2 SD, SN-MC-ICP-MS); ±0.08–0.14‰ (2 SD, LA-MC-ICP-MS) | 338 |
| Fe oxidation state | Garnet | EPMA flank method | And1902, Grs1928, MelS01, Ald1906, Ald1915, Ald1917, Ald1905, Ald1907, Ald1925, Ald1926 | Ten natural RMs: three andradite–grossular; seven almandine–pyrope–grossular (Ald). Fe Lα/Fe Lβ intensity ratio correlates with oxidation state. And1902 & Ald1906 suitable as primary flank standards. And-Grs: Fe3+/ΣFe = 0.89 ± 0.03 to 1.00 ± 0.03; Ald: 0.01 ± 0.02 to 0.03 ± 0.01. Agrees with Mössbauer. Uncertainty: ±1 wt% (Fe2+); ±0.05 (Fe3+/ΣFe) | 339 |
| Fe & Mg isotopes | Olivine | LA-MC-ICP-MS | CUG-OL-Ar | Sintered olivine RM (solid-phase sintering + ultrafine powder). δ56FeIRMM-014 = 0.00 ± 0.06‰ (2 SD, N = 350); δ25MgSC = 0.00 ± 0.05‰ (2 SD, N = 350). Excellent homogeneity and analytical performance. Long-term precision < 0.11‰ (Fe); < 0.08‰ (Mg) | 340 |
| Cl, CO2, F, H2O, S | Basaltic silicate glasses | SIMS | ND70 series | RMs range: H2O 0–6% w/w; CO2 0–1.6% w/w; S, Cl, F 0–1% w/w. Characterised via ERDA, NRA, EA, FTIR, SIMS, EPMA. Good inter-technique agreement except CO2. SIMS reproducibility poor at high H2O due to 12C ionisation effects | 178 |
| Hf isotopes | Cassiterite | LA-MC-ICP-MS | CST01, CST02, CST03 | Homogeneity at 30 µm. 176Hf/177Hf: 0.282262 ± 0.000022 (2 SD, N = 200); 0.282273 ± 0.000031 (2 SD, N = 348); 0.282276 ± 0.000049 (2 SD, N = 517) | 171 |
| Li isotopes | Lepidolite | LA-MC-ICP-MS | NWU-LPD | Recommended reference δ7Li value: 8.70 ± 0.28‰ (2SD, N = 5) | 341 |
| Lu–Hf dating | Garnet | LA-ICP-MS/MS | GWA-1, GWA-2 | GWA-1 (almandine-grossular), Lu ≈ 7.0 µg g−1; GWA-2 (almandine-spessartine), Lu ≈ 8.5 µg g−1 | 342 |
| Crystallisation ages: 1267.0 ± 3.0 Ma with initial 176Hf/177Hfi: 0.281415 ± 0.000012 (GWA-1), and 934.7 ± 1.4 Ma with 176Hf/177Hfi: 0.281386 ± 0.000013 (GWA-2) | |||||
| O isotopes | Calcite | SIMS | WS-1 | SIMS spot-to-spot reproducibility < 0.21‰ (1 SD). δ18OVPDB (gas-source IRMS): −16.52 ± 0.13‰ (1 SD). Mean SIMS: −16.44 ± 0.25‰ (1 SD, N = 225). Useful for inorganic aragonites and low-Mg calcites; beware matrix effects in high-Mg organic skeletal calcites | 343 |
| O isotopes | Xenotime | SIMS | PX xenotime | From Zagi Mountain (Pakistan). Homogeneous by SIMS. δ18O (LF-IRMS): 6.25 ± 0.13‰ (2 SD, N = 6) | 344 |
| O isotopes | Spodumene | SIMS | Tri-1, Kun-A-1, MG-1 | Bulk δ18O(VSMOW) by LF-IRMS: 11.29 ± 0.04‰; 9.12 ± 0.10‰; 15.13 ± 0.08‰ (2 SE). Homogeneous at nanogram scale by SIMS (2 SD < 0.24‰; N > 20). No crystal-orientation effects on SIMS mass bias | 345 |
| Rb isotopes | Latosol | MC-ICP-MS | GSS-7 | Mean δ87RbSRM984: −0.08 ± 0.02‰ (2 SD, N = 9). Accuracy tested by mixing with NIST SRM 984: δ87RbSRM984 = 0.02 ± 0.02‰ (2 SD, N = 3); similar composition mix: 0.03 ± 0.02‰ (2 SD, N = 3) | 346 |
| Rb isotopes | Pegmatite | ID-TIMS/MC-ICP-MS | OU-9 | Rb = 2494 ± 22 µg g−1; Sr = 36.05 ± 0.25 µg g−1. 87Rb/86Sr = 832.4 ± 5.2; 87Sr/86Sr = 32.60 ± 0.19. Not fully homogeneous in Rb and Sr mass fractions, but Rb–Sr systematics at 0.2 g scale agree with reference isochron. Isochron age ≈2650 Ma; initial 87Sr/86Sr ≈ 1.2 | 347 |
| Rb–Sr dating | Muscovite | LA-MC-ICP-MS/MS | ZMT04 | Rb–Sr isochron age: 1778.8 ± 4.9 Ma (2SD, N = 180), consistent with 40Ar/39Ar 1772.2 ± 2.7 Ma (2SD). Inter-session RSD: 0.69% | 348 |
137Ba, 140Ce, 133Cs, 163Dy, 166Er, 151Eu, 157Gd, 177,178Hf, 165Ho, 139La, 175Lu, 93Nb, 146Nd, 141Pr, 85Rb, 149Sm, 88Sr, 181Ta, 159Tb, 232Th, 169Tm, 238U, 89Y, 172Yb, 90,91Zr |
Black shales | ICP-HR-MS | SChS-1A SLg-1A | Contents of 25 elements after fusion with lithium metaborate; mean error <5% | 349 |
| S isotopes | Barite | LA-ICP-MS | 1-YS, 294-YS | Natural pure barite. SEM: Main composition BaO, SO3, SrO (minor Na2O, Al2O3). BSE: homogeneity in S, Ba, Sr. δ34S reproducibility < ±0.45‰ (2SD, 1-YS); < ±0.41‰ (2SD, 294-YS). δ34S recommended (four labs): 1 YS 13.37 ± 0.42‰; 294-YS 14.38 ± 0.44‰ (2 SD) | 350 |
| S isotopes | Barite | SIMS | NJU-Ba-1, NJU-Ba-2 | No internal zoning. δ34SV-CDT (GS-IRMS): 6.18 ± 0.34‰ (2SD, N = 17); 14.16 ± 0.26‰ (2 SD, N = 9). SIMS homogeneity inter-/intra-unit: variation 0.36‰ (2SD, N = 328); 0.45‰ (2SD, N = 343) | 351 |
| S isotopes | Pyrite | LA-MS-ICP-MS, LG-SIMS and NanoSIMS | M332, MK617 | S homogeneity confirmed in situ and matches IRMS. δ34S (IRMS): M332 24.96 ± 0.22‰ (2SD, N = 10); MK617–4.43 ± 0.21‰ (2SD, N = 12). δ33S (SIMS): MK617 12.89 ± 0.60‰ (2SD, N = 104); M332–2.23 ± 0.35‰ (2SD, N = 120) | 352 |
| S isotopes | Pyrite, gypsum and aresenopyrite | LA-MC-ICP-MS | NWU-Py, NWU-Gy, NWU-Apy | Ultra-fine powder hot-press sintering: high homogeneity. δ34S: NWU-Py 3.48 ± 0.26‰ (2SD, N = 787); NWU-Gy 18.19 ± 0.32‰ (2SD, N = 290); NWU-Apy −0.19 ± 0.32‰ (2SD, N = 383). Agrees with IRMS | 173 |
| S isotopes | Sphalerite | LA-ICP-MS | Sph-LD | Mean δ34S: +17.11 ± 0.20‰ (2SD, N = 560), comparable with IRMS (+17.22 ± 0.20‰, 2SD, N = 10). Elemental homogeneity <10% at 26–40 µm | 174 |
| Sr isotopes | Apatite | LA-MC-ICP-MS | SL-7, SM139-1 | EPMA/LA-ICP-MS: Cl 1.80–2.46 wt%; Sr > 3752 µg g−1; low Rb/Sr. 87Sr/86Sr: 0.70521 ± 0.00016 (2SD, N = 120) and 0.70509 ± 0.00015 (2SD, N = 126). Agrees with solution TIMS/MC-ICP-MS | 353 |
| Sr isotopes | Calcite | LA-MC-ICP-MS | HZZ-2, TARIM | Homogeneous natural calcite RMs (µ-XRF, EPMA, LA-ICP-MS). Rb/Sr < 1 × 10−5; Sr ∼1100 µg g−1 (HZZ-2), ∼620 µg g−1 (TARIM). TIMS 87Sr/86Sr: 0.70941 ± 0.00001 (2SD, N = 8); 0.71042 ± 0.00001 (2SD, N = 7). Consistent with LA-MC-ICP-MS | 354 |
| U–Pb dating, Hf isotope measurement | Baddeleyite | LA-MC-ICP-MS | SK 10–3 | Transparent grains (150–300 µm, aspect ratio 2 : 1–3 : 1), inclusion-free, uniform U–Pb ages. LA-ICP-MS weighted mean 206Pb/238U: 31.59 ± 0.11 Ma (MSWD = 0.7, N = 197). 176Hf/177Hf: 0.282741 ± 59 (2SD, N = 188). ID-TIMS 206Pb/238U: 31.592 ± 0.020/0.022/0.040 Ma (2SD, N = 7). MC-ICP-MS 176Hf/177Hf: 0.282742 ± 8 (2SD) |
355 |
| U–Pb dating | Andradite-rich garnet | ID-TIMS, SIMS, LA-ICP-MS | MKWB, DGS, Stanley | Three natural andradite RMs: MKWB (secondary U–Pb & trace RM), DGS (very homogeneous U–Pb age), Stanley (secondary RM). Multi-lab and multi-technique homogeneity. ID-TIMS 206Pb/238U: MKWB 264.9 ± 5.8 Ma (2SD, N = 6, MSWD = 3.4); DGS 139.42 ± 0.36 Ma (2SD, N = 5, MSWD = 1.9); Stanley 23.28 ± 0.38 Ma (2SD, N = 3, MSWD = 1.9) | 356 |
| U–Pb dating | Columbite-tantalite | LA-ICP-MS | OXF | U, Th, Pb concentrations: 428 ± 156 ppm; 6.3 ± 2.5 ppm; 20.0 ± 10.0 ppm (2SD). CA-ID-TIMS 206Pb/238U: 262.85 ± 0.64 Ma (2SD, N = 6). LA-ICP-MS weighted mean (4 labs): 262.83 ± 0.29 Ma (2SD, N = 358) | 357 |
| U–Pb dating | Titanomagnetite | LA–SF–ICP-MS | HG79c | RM age: 259.2 ± 2.8 Ma, consistent with Concordia-intercept 206Pb/238U using cassiterite AY-4 as external standard. Accurate also using zircon 91500 and garnet PL-57 calibration | 358 |
| U–Pb dating | Grossular-Andradite Garnet | LA-ICP-MS | And99, And87, And87 | IC-TIMS single-crystal age precision ∼0.1%. RMs: And99 (Jumbo andradite) 110.34 ± 0.13 Ma (N = 7); And87 (Tiptop andradite) 209.58 ± 0.28 Ma (N = 6). Primary RM And90 (Willsboro-Lewis) age 1024.7 ± 9.5 Ma (2 SD, N = 6) | 359 |
| U–Pb/Lu–Hf dating | Xenotime | LA-ICP-MS/MS | Xtm-NHBS | ID-TIMS 206Pb/238U: 498.7 ± 0.4 Ma (2SD, N = 5). LA-Q/SF-ICP-MS spots: Lu–Hf weighted means: 502.1 ± 3.6 Ma (2SD, N = 39); 494.6 ± 3.8 Ma (2SD, N = 40) | 360 |
| U–Th–Pb, (U–Th)/He dating, Hf–O isotopes | Zircon | LA-ICP-ToF-MS | Zircon-S513 | U, Th, Pb, Hf: 924 ± 64.6; 89.6 ± 3.92; 119 ± 5.20; 8259 ± 244 µg g−1 (2SD). ID-TIMS Th-corrected ratios: 206Pb/238U 0.090955 ± 0.000019; 207Pb/235U 0.73873 ± 0.00023; 207Pb/206Pb 0.058934 ± 0.000008 (2SD, N = 8). CA-ID-TIMS Th-corrected 206Pb/238U age: 561.18 ± 0.63 Ma (N = 8). LA-ICP-MS/SIMS 206Pb/238U ages: 560.8 ± 5.8/10.2 Ma (2SD, N = 260); 562.4 ± 7.2/13.4 Ma (2SD, N = 198). LA 208Pb/232Th: 561.3 ± 3.3/11.7 Ma (2SD, N = 86). (U–Th)/He age: 420.3 ± 7.6 Ma (2SD, N = 37). 176Hf/177Hf MC-ICP-MS: 0.281606 ± 0.000010 (2SD, N = 12); LA: 0.281605 ± 0.000008 (2SD, N = 310). δ18O (LF): 11.71 ± 0.11‰ (2SD, N = 5). Homogeneity: ≤8% (1σ) in major/minor elements, 0.12‰ (2SD) in U–Pb, 1.8% (2SD) in (U–Th)/He, 0.0036% (2SD) in Hf, 0.11‰ (2SD) in O | 361 |
| U–Th–Pb dating | Allanite | LA-ICP-MS | AMK, ASP | 206Pb with respect to total 206Pb content below 0.8 and 5.5%. AMK, U and Th concentrations: 140 ± 41.9 µg g−1 (1SD) and 306 ± 145 µg g−1 (1SD), respectively. ASP, U and Th concentrations: 261 ± 143 µg g−1 (1SD) and 130 ± 102 µg g−1 (1SD), respectively. Weighted mean 207Pb/206Pb age: 1533.6 ± 1.9 Ma (2SD, N = 6) for AMK and weighted mean 206Pb/238U age: 335.86 ± 0.52 Ma (2SD, N = 8) for ASP (ID-TIMS). AMK proposed as primary RM for LA-ICP-MS U–Th–Pb dating and ASP as secondary RM | 179 |
| U–Th–Pb dating, O–Nd isotopes | Monazite | LA-ICP-MS SIMS | M6 | ThO2 = 10.7 ± 1.1% (2SD); Th/U = 28.4 ± 3.3 (2SD). Age reproducible and homogeneous at 30 µm (LA-ICP-MS & SIMS), concordant with ID-TIMS. ID-TIMS 207Pb/235U 485.7 ± 2.3 Ma (2SD, N = 7). Sm–Nd (LA-MC-ICP-MS): 143Nd/144Nd = 0.511829 ± 0.000045 (2 SD); 147Sm/144Nd = 0.2302 ± 0.0139 (2SD). δ18O (SIMS): 7.70 ± 0.41‰ (2SD) | 362 |
Production of new RMs with required elemental or isotopic compositions involved a doping process. Synthesizing B4C with natural and enriched isotopic ratios via carbothermic reduction or direct reaction, followed by pelletizing, vacuum heating (∼1800 °C), and grinding provided RMs with 10B/11B ratios between 0.247–2.03 for in-house measurements by particle induced γ-ray emission (PIGE).176 Production of a columbite matrix standard for LA-ICP-MS applications177 involving doping with a multielement standard solution, and extended milling (90% of particles ≤1.74 µm), which enabled pressed pellet calibrants with smooth, glass-like surfaces to be produced. Preparation of RMs doped with volatile species (Cl, CO2, F, H2O, S) was however more challenging. Basaltic glass RMs were produced178 by melting crushed material at 1350 °C, quenching, and re-melting to degas, followed by addition of volatile species by pressurised diffusion at 1–1.5 GPa and 1225–1325 °C for 2 h in a sealed system.
The lack of suitable RMs with low non-radiogenic Pb content has hindered U–Th–Pb dating in allanite. Two new matrix-matched allanite RMs with reduced common Pb, titled AMK and ASP, see Table 10, were proposed179 as alternatives to the widely used Tara allanite standard, removing the need for common Pb correction, improving robustness and simplifying dating procedures.
The suitability of the widely used NIST SRM 610 and 612 (trace elements in glass) for microanalysis by LA-ICP-MS was evaluated.180 Calibration uncertainty was shown to be a major limitation for high-precision microscale measurements, demonstrating a need for new RMs with certified microscale homogeneity for their trace element content.
Interest in obtaining novel elemental composition and isotopic data for established geological reference materials (RMs) remains high. This updated information is crucial for validating current analytical methodologies and is reported in Tables 11 and 12 respectively.
| Analytes | Matrix | Technique | Comments | References |
|---|---|---|---|---|
| Ba isotopes | Sediments | MC-ICP-MS | Sediments NGRCC: GSD-1, GSD-2, GSD-3, GSD-6, GSD-7, GSD-7a, GSD-8, GSD-11 and GSD-14. δ138/134Ba: from 0.03 ± 0.05‰ to – 0.08 ± 0.06‰ (2SD, n = 5) | 363 |
| Cd isotopes | Chondrite | MC-ICP-MS | L3.2 ordinary chondrite GRO 95504. Cd = 20.7 ± 0.5 ng g−1; δ114Cd = 7.55 ± 0.08‰ | 129 |
| Ce isotopes | Igneous rocks, metamorphic rocks, sediments, soils | MC-ICP-MS | 33 USGS, GSJ, IGGE RMs. Precision ±0.04‰ (2SD). δ142/140Ce: igneous rocks (−0.036 to 0.062‰), soils (−0.015 to 0.029‰), sediments/nodules (−0.005 to 0.141‰) | 98 |
| Fe oxide | Igneous, sedimentary, metamorphic rocks | XRF | GeoPT samples (35). FeO from 0.07 to 11.88% | 364 |
| Ga isotopes | Granodiorite, gabbro, granite, clayey limestone, jasperoid, soil, shale, sediment | MC-ICP-MS | GSJ JG-1 (granodiorite): δ71Ga = −1.36 ± 0.06‰ (2SD, n = 6); USGS JGb-2 (gabbro): δ71Ga = −1.48 ± 0.01‰ (2SD, n = 4); IGGE GSR-1 (granite): δ71Ga = −1.31 ± 0.05‰ (2SD, n = 2); IGGE GSR-6 (clayey limestone): δ71Ga = −1.41 ± 0.04‰ (2SD, n = 4); USGS GXR-1 (jasperoid): δ71Ga = −1.39 ± 0.07‰ (2SD, n = 6); USGS GSS-11 (soil): δ71Ga = −1.32 ± 0.04‰ (2SD, n = 2); IGGE GSS-12 (soil): δ71Ga = −1.40 ± 0.04‰ (2SD, n = 4); NIST 2711a (soil): δ71Ga = −1.31 ± 0.06‰ (2SD, n = 2); USGS SGR-1b (shale): δ71Ga = −1.40 ± 0.02‰ (2SD, n = 2); USGS GSD-12 (sediment): δ71Ga = −1.37 ± 0.05‰ (2SD, n = 4) | 365 |
| Hg isotopes | Coal, Cu–Ag sulfide ore, Au–Te sulfide ore | MC-ICP-MS | A dual-stage tube furnace system containing a Mn catalyst tube was used to pretreat mineral ore samples | 183 |
| NCRM RMs: GBW-11108v, coal: δ202Hg = −1.02 ± 0.05‰ and Δ199Hg = −0.31 ± 0.03‰ (1SD, n = 6); GSO-3, Cu–Ag sulfide ore: δ202Hg = 0.25 ± 0.04‰ y Δ199Hg = −0.12 ± 0.02‰ (1SD, N = 6); GBW 07859, Au–Te sulfide ore: δ202Hg = −0.97 ± 0.06‰ and Δ199Hg = 0.08 ± 0.03‰ (1SD, n = 6) | ||||
| I/Ca ratios | Carbonate, coral | LA-ICP-MS | JCp-1 (coral) more homogeneous and reproducible than MACS-3. Suitable as calibration RM for I/Ca profiling. I distribution much more homogeneous for JCp-1 (1.03%) than for MACS-3 (30.0%). Better repeatability for Mg, Sr, Ba and U for the former RM. JCp-1 more suitable as calibration standard for high resolution (<100 µm) I/Ca profiling and multielemental analysis of corals using LA-ICP-MS | 366 |
| Ir levels | Mafic intrusive rocks, felsic rocks, sedimentary rocks, metamorphic rock | MC-ICP-MS | 11 USGS RMs. Ir contents: mafic intrusive rocks (DTS-2 and W-2), felsic rocks (GSP-2, QLO-1, GSR-1, JG-2 and JR-2), sedimentary rocks (SBC-1, Nod-A-1 and COQ-1) and metamorphic rock (SDC-1) (in pg g−1): 2983 ± 455; 383 ± 26; 18 ± 3; 6 ± 2; 4 ± 0 5 ± 0; 9 ± 3; 105 ± 30; 8661 ± 980; 22 ± 6; 22 ± 6 | 367 |
| K isotopes | Igneous, sedimentary, metamorphic rocks | MC-ICP-MS | δ 41K for 18 NRC RMs geological RMs with K2O mass fractions ranging from 0.15 to 7.5%. δ41K values ranging from −1.15‰ (GBW07122, GSR 15, amphibolite) to 0.28‰ (GBW07120, GSR 13, limestone), with an intermediate measurement precision of 0.05‰ (2SD). New data provided for six RMs | 368 |
| Li isotopes | Sediments, soils, rocks | MC-ICP-MS/MS | Data provided for NIST SRMs 1646a (estuarine sediment), 2706 (New Jersey soil), 2711a (Montana II soil), 2780a (hard rock mine waste), and 4350b (Columbia River sediment) | 369 |
| δ 7Li: 3.79 ± 0.63‰; 2.50 ± 0.53‰; −0.28 ± 0.23‰; 5.10 ± 0.15‰; 0.94 ± 0.06‰ (2S, N = 3), respectively | ||||
| Mg isotopes | Gabbro, diabase, basalt, andesite, granite, rhyolite, schist, mudstone, quartz sandstone, limestone, clayey limestone, dolomite, fluvial sediments, manganese nodules | MC-ICP-MS | USGS, GSJ and NRCCRM RMs. Felsic and mafic igneous rocks: gabbro (JGb-2); diabase (DNC-1a); basalt (JB-1b, JB-2); andesite (GSR-2, JA-2); syenite (STM-2); granite (GSR-1, JG-1); rhyolite (GSR-11, RGM-2, JR-1, JR-3). Metamorphic rocks: micaceous schist (SDC-1). Sedimentary rocks: mudstone (GSR-5); quartz sandstone (GSR-4); limestone (GSR-13); clayey limestone (GSR-6); dolomite (JDO-1, GBW07127a). Sediments: soil (GSS-4); fluvial sediments from different regions (GSD-1, GSD-3, GSD-9, GSD-21, GSD-23). Manganese nodules (NOD-A-1, NOD-P-1). Minerals: soapstone (GBW03130); kaolinite (GBW03121a); wollastonite (GBW03123) | 370 |
| Mg isotopes | Carbonates | MC-ICP-MS | NCRM RMs magnesite GBW07865, dolomites GBW07114, GBW(E)070159, GBW07136, limestone GBW07108, gypsum GBW03109a, limestones GBW07120 and GBW07214a, and RMs IAEA-B-7 and carbonatite IAEA–CO–8. Mg content: 295 µg g−1; Ca to Mg mass ratios around 1300 g g−1 | 371 |
| Mo isotopes | Granite, andesite, olivine basalt, syenite, trachyte, granodiorite, rhyolite, amphybolite, soils | MC-ICP-MS | NCRM RMs analysed: granite GBW07103, andesite GBW07104, olivine basalt GBW07105, syenite GBW07109, trachyte GBW07110, granodiorite GBW07111, rhyolite GBW07113, amphibolite GBW07122, soils GBW07401a, GBW07405a and GBW07407 | 372 |
| δ 98/95Mo: igneous −0.54‰ to +0.01‰; amphibolite −0.04 ± 0.08‰; soils −0.28‰ to +0.22‰. Mo from 0.07 to 3.92 µg g−1, RSD 0.05–5.30% | ||||
| Ni, Cu & Zn isotopes | Basalt, andesite, granodiorite, Mn nodule, sulfide ore, sediments, soil, mud | MC-ICP-MS | δ 60NiNIST986, δ65CuNIST976 and δ66ZnJMC-Lyon provided for 36 NIST, IRMM, NRC, USGS and GSJ geological RMs | 99 |
| S isotopes | Marine sediments | CR-IR-MS | USGS and GSJ RMs: Marine sediments (JMs-1, JMs-2), marine shales (SBC-1, SCo-2), stream sediments (JSd-3, JSd-4) and lacustrine sediment (JLk-1). New data set including abundances of total S, HCl-insoluble S, and their isotopic ratios (δ34STotal S, δ34SHCl-insoluble S, and δ34SCr reductible S) for the RMs | 373 |
| Sb isotopes | Basalt, andesite, amphibolite, quartz sandstone | HG-MC-ICP-MS | 113/111Cd element doping and SSB improved precision (2SD) from 0.08‰–0.12‰ to 0.02‰–0.08‰. δ123Sb: USGS BCR-2 (0.28 ± 0.09‰, 2SD, n = 9), USGS AGV-2 (0.23 ± 0.11‰, 2SD, N = 6), NCRM GSR-15 (0.36 ± 0.09‰, 2SD, N = 6), and NCRM GSR-4 (0.49 ± 0.06‰, 2SD, N = 9) | 131 |
| Sn isotopes | Basalt, dunite, quartz latite, rhyolite, shale, syenite, dolomite, peridonite, komatiite, serpentine | MC-ICP-MS | δ 122/118Sn(NIST SRM) (3161a) for USGS BIR-1a, Icelandic basalt; USGS DTS-2b, dunite; USGS QLO-1a, quartz latite; USGS RGM-2, rhyolite; USGS SGR-1b, shale; USGS STM-2, syenite; BAS ECRM 782–1, dolomite; CPRM BRP-1, basalt: GSJ JP-1, peridotite; IAG OKUM, komatiite; ANRT UB-N, serpentine | 374 |
| Ti isotopes | Ilmenite, titanite | LA-MC-ICP-MS | δ 49TiOL-Ti with solution nebulization MC-ICP-MS: ilmenite GER16: −0.24 ± 0.05‰ (2SD, n = 6); titanite MAD12: 0.26 ± 0.06‰ (2SD, n = 4) | 375 |
| LA-MC-ICP-MS data in good agreement | ||||
| Ilmenite GER16: ns-LA-MC-ICP-MS (wet plasma) δ49Ti = −0.22 ± 0.17‰ (2SD, n = 28); ilmenite GER16: fs-LA-MC-ICP-MS (wet plasma) δ49Ti = −0.24 ± 0.13‰ (2SD, n = 42) | ||||
| Titanite MAD12: ns-LA-MC-ICP-MS (wet plasma) δ49Ti = 0.25 ± 0.14‰ (2SD, n = 21); titanite MAD12: fs-LA-MC-ICP-MS (wet plasma) δ49Ti = 0.23 ± 0.16‰ (2SD, n = 45) | ||||
| Tl isotopes | Stream sediment, soil, shale, granodiorite, granite, nepheline syenite, trachyte, rhyolite | MC-ICP-MS | 205Tl/203Tl ratios determined in ten geological RMs: SGR-1b (from the USGS), and GBW07302, GBW07303a, GBW07401a, GBW03104, GBW07103, GBW07109, GBW07110, GBW07111 and GBW07113 (from China). Dry ash digestion causes heavy isotope enrichment vs. acid digestion. ε205Tl validated with USGS RMs | 376 |
| Element | Matrix | Sample preparation | Technique | Comment | References |
|---|---|---|---|---|---|
| Ag | Ultramafic, mafic to felsic igneous rocks, sediments, soils | NH4HF2 digestion + ammonia coprecipitation | ID-ICP-MS | Polyatomic interferences (Zr, Nb, Y) corrected, ID compensated Ag loss. LOQ 1.83 ng g−1; RSD 0.4–7% | 377 |
| Al isotopes | Carbonaceous chondrites | Thin polished sections | SIMS | Six 26Al/27Al0 values near canonical (5.2 × 10−5); inclusions formed during main thermal event | 378 |
| As, Tl | Sphalerite and associated phases | Comparison with RMs (realgar, orpiment, mimetite, lorandite, synthetic Tl silicate) | XANES | Derivative analysis distinguished As from As3+; Tl spectra confirmed monovalent Tl. Demonstrated oxidation state discrimination in ore systems | 379 |
| B isotopes | Carbonates | Direct LA | LA-ICP-MC-MS | Ca-rich matrices and ionized Ar increased background at m/z ≈ 10, complicating δ11B accuracy. Differences in ablation rates between samples and standards introduced isotopic bias | 380 |
| B isotopes | Silicate, peridotite, coral, calcite, aragonite, basalt glass | Mounting/pellets | LA-MC-ICP-MS/MS | Precision <1‰ (≥40 mV). δ11B of 14 RMs within uncertainty; design minimized Ar, Ca interferences | 381 |
| B isotopes, major and minor elements | Silicates | Milling, pelleting, epoxy mount | LA-ICP-MS | 51 elements + δ11B; new δ11B for GSJ JP-1, BHVO-1, BCR-1, JG-1a. Precision ±0.3–0.4‰; elements within ±20% of GeoReM | 382 |
| C isotopes | Diamond | Mounted in Sn alloy | LA-MC-ICP-MS | In situ δ 13C precision <0.2‰ (S/N ratio > 4). Accuracy validated vs. NanoSIMS/LA-IRMS. Mass fractionation 19.4‰ between natural/synthetic | 383 |
| C isotopes | Carbonates | In situ analysis at 90 µm spatial resolution | LA-ICP-MC-MS | Doubly charged Mg2+ ions cause isobaric interference on δ13C measurements. Optimized He/Ar ratios and N2 addition (4–6 mL min−1) enhanced signal intensity and minimised Mg2+ formation. Iterative mass bias correction yielded accurate δ13C values | 384 |
| Ca isotopes | Coral, dolomite, and limestone | Digestion with HNO3/HCl = 3 : 1 v/v at 95 °C for 60 min |
ICP-MS/MS | Ozone was proposed for Ca isotope analysis, overcoming the 40Ar interference via CaO3+ and ArO+ generation | 385 |
| Ca isotopes | Calcite, dolomite | Direct ablation | LA-MC-ICP-MS | High-Sr carbonates; iterative correction improved accuracy. δ44/42Ca: 0.10–0.19‰, δ43/42Ca: 0.09–0.12‰ (2SD) | 386 |
| Ba, Ca, Ce, Nd, Sr | Manganese nodules, andesite, basalt, granodiorite, carbonatite, simulated lunar soils | Digestion + multi-column separation | TIMS (Ca, Sr and Nd); MC-ICP-MS (Ba and Ce) | USGS analysed RMs: basalt (BHVO-2), manganese nodule powder (NOD-A-1), andesite (AGV-2), granite (GSP-2), and carbonate rock (COQ-1). Simulated lunar soil samples (CUG-1A and CUG-1B). Accurate simultaneous separation/measurement from 1–2 mg. High recovery (>99.5%), blanks <0.1%. Simultaneous separation and accurate measurement of Ca, Sr, Ba, Ce, and Nd isotopes from 1–2 mg. High recovery (>99.5%), low procedural blanks (<0.1%). First Sr, Ba isotope data for NOD-A-1, and those of Ca, Sr, Ba, Ce, and Nd from the simulated lunar soils CUG-1A and CUG-1B | 387 |
| Cd isotopes | Basalt, soil, shale, manganese nodules | Acid digestion + anion exchange | MC-ICP-MS | By measuring 106Cd, 110Cd, 111Cd, and 113Cd, the 114Cd isotope was calculated, circumventing 114Sn interference. Analysis of four geochemical RMs verified δ114/110Cd values consistent with literature. Novel 106Cd–111Cd double spike avoids Sn interference and simplifies separation | 388 |
| Eu isotopes | Basalt, sienite | HF/HNO3 digestion + two-step purification | MC-ICP-MS | Nd internal normalization improved stability and reproducibility of Eu isotope measurements long-term external precision of δ153/151Eu at 0.04‰ (2SD) | 389 |
| Fe isotopes | Biotite, hornblende, pyroxene, olivine | Polished thin sections | fs-LA-MC-ICP-MS | Intermediate precision of 0.17‰ (2SD) for δ56Fe over 3 years and consistency with previous data. Uncertainties for glass and olivine < 0.15‰. Spatial resolution was below 30 µm | 390 |
| Fe and Mg isotopes | Basalt, andesite, serpentine, granite, dolomite, coral | HF/HNO3 digestion + single-column separation | MC-ICP -MS | Geological RMs: USGS Basalt, USGS BHVO-2, BCR-2 and GSJ JB-1; andesite, USGS AGV-2; serpentine, ANRT UB-N; granite, USGS G-2 and GA; dolomite, NMIJ JDo-1; and coral, GSJ JCp-1. Low sample sizes, <10 ng. Fe and Mg recoveries > 98% with removal of matrix elements Al, Ti, Na, K, Ca. The full purification procedure requires 1 day | 391 |
| δ 56Fe and δ26Mg values consistent with literature | |||||
| Fe and Zn isotopes | Andesites, basalts, granodiorites | HF/HNO3 digestion + AG1-X8 purification | MC-ICP-MS | Use of a combined approach of element doping and standard-sample bracketing. RMs: USGS BCR-2, BHVO-2, AGV-2 and GSP-2, and GSJ JA-1, JA-2, JB-1b, JB-2, JG-1 and JG-2. Recoveries > 99.5%. Long-term analytical precision: ±0.05‰ for δ56Fe and ±0.03‰ for δ66Zn. New Fe isotope data had been previously reported for JG-1. For JG-2, Fe isotope values higher than previously published data | 392 |
| Ge isotopes | Basalts, meteorites | Digestion, two-steps ionic exchange separation | MC-ICP-MS | Double-spike approach; HG introduction beneficial for low Ge | 393 |
| Ar, He, Ne, isotopes | Extraterrestrial materials (ilmenite and olivine) | Co-implantation of noble gases simulating solar wind irradiation | LIMAS | Enabled nanoscale noble gas profiling. Achieved low LODs, reproducible isotopic ratios, and 5–31% (1SD) RSF reproducibility | 394 |
| Hf and Nd isotopes | Basalt, andesite, serpentine | Hot plate digestion + three-steps ionic chromatography purification | MC-ICP-MS | High sensitivity (<10 ng). Apex omega desolvation gave low oxides (<0.05%) and interference removal (Ce, Sm) | 395 |
| K isotopes | Granite, basalt | HF/HNO3 digestion + AG50W-X12 resin | MC-ICP-MS/MS | Interferences (40ArH+) corrected with H2. CRC. δ41K for USGS BCR-1, basalt = −0.37 ± 0.12‰ (2 SD) and for CRPG GA, granite = −0.46 ± 0.07‰ (2 SD). Data in agreement with previously published work | 396 |
| Lu–Hf dating | Allanite | Epoxy mounts | LA-ICP-MS | Nine allanite samples from different rock types (e.g., granite, pegmatite). Ages 2650–100 Ma; calibration with NIST SRM 610 + LE2808. Precision <5% | 397 |
| Multi-element | Sedimentary rocks | Calibrated using stoichiometric materials; compared three scanners (medical CT, HECTOR µCT, CoreTOM µCT) | DECT | Determined Zeff and ρe; assessed X-ray energy, resolution, and calibration effects. Highlighted lack of universal protocol for geoscientific DECT | 398 |
| O isotopes | Quartz grains from river sediments and turbidites | Individual quartz grains (∼200) isolated from Himalayan catchments and Bengal Fan sediments | LG-SIMS | Used δ18O signatures to discriminate magmatic, metamorphic, and sedimentary sources. δ18O values ranged 5–25‰; overlap (∼11‰) between Trans- and Lesser Himalaya but geological context enabled distinction. Complements detrital zircon provenance analysis | 399 |
| O isotopes | Quartz grains in river sediments | Drying and sieving. Subsequent quartz preconcentration with Na-polytungstate and dissolution with H2SiF6 and HCl. Pressing and polishing and cleaning with ethanol and Au coating | LG-SIMS | δ 18O signature ranged from 5‰ for Trans-Himalayan batholiths to 25‰ for the Tethys Himalayan zone | 399 |
| Os isotopes | Peridotite, chromitite, ultrabasic rocks | Sb fire assay + distillation | MC-ICP-MS | Large sample amounts (>20 g) enabled analysis of low-Os samples (<1 µg kg−1). Validated vs. six IGGE RMs (WPR-1, GPt-5, GPt-6, GPt-3, GBW07102 and GPt-4) | 400 |
| Rb isotopes | Peridotite, komatiite, ultramafic rock | Digestion + ion exchange | MC-ICP-MS | Aridus III + Ni cones reduced requirements (∼20 ng Rb). Precision <0.05‰. SSB with internal Zr normalization provided improved intermediate precision, though SSB was adequate for accuracy | 346 |
| Re isotopes | Basalt, diabase, andesite | Digestion + TEVA resin purification | MC-ICP-MS | Purification blank (<0.2 pg), Re yield 93.2 ± 2.4%, 2SD, N = 5). δ187ReSRM3143 precision 0.048‰ (1 ng g−1). Consistent δ187Re values for multiple RMs | 401 |
| Re isotopes | Basalts, marine mud, shales | Heating + digestion + AG1-X8 purification | MC-ICP-MS | Applied to USGS RMs: BCR-2, BIR-1, BHVO-2, basalts, SDO-1, SBC-1, SGR-1, shales with ∼0.5–75 ng g−1 for Re. Re recovery = 99.6 ± 6.7%, 2SD, N = 10; δ187Re = −0.49 ± 0.04‰, 2SD, N = 10. Procedural blank for solid materials: 8 ± 3 pg (2SD, N = 7). Re isotope reported for the first time for SBC-1 (shale), δ187Re: −0.45 ± 0.06‰ (2SD, N = 4) and SGR-1 (shale), δ187Re: of −0.27 ± 0.10‰ (2SD, N = 5). Variation in δ187Re for schists: ∼0.35‰ | 402 |
| Si isotopes | Basalt, peridotite, diatomite | NaOH fusion + AG50W-X12 purification | MC-ICP-MS | Double-spike. δ30/28Si precision ±0.03‰; δ30/28SiNBS28, for USGS RM BHVO-2 (−0.276 ± 0.011‰, 2SD, N = 94), USGS RM BIR-1 (−0.321 ± 0.025‰, 2SD, N = 27), GSJ RM JP-1 (−0.273 ± 0.030‰, 2SD, N = 19) and diatomite (1.244 ± 0.025%, 2SD, N = 20) | 403 |
| Sn isotopes | Basalts, zinc ore, granite and soil | HNO3–HCl digestion + two-stage chromatography | MC-ICP-MS | Neoma less affected by isobaric interferences than the Neptune. Sn recoveries 85 ± 5%, double spiking. RMs: Granodiorites (USGS GSP-2), basalts (USGS BCR-2, USGS BHVO-2, AISTJB-3), granite (IAG OU-3), zinc ore (AIST JZn-1), soil (NIST SRM2711a). δ124/116SnSRM3161a reported for the first time: 0.6 ± 0.1‰ (2SD, N = 2); 0.8 ± 0.08‰ (2SD, N = 4); −0.87 ± 0.07‰ (2SD, N = 2); and −0.12 ± 0.08‰ (2SD, N = 3), for the RMs: OU-3, JB-3, JZn-1and NIST SRM 2711a, respectively | 404 |
| Sn isotopes | Basalt, andesite, granite, sediment, soil | Acid digestion + AG1-X8 + AG50W-X12 | MC-ICP-MS | Interferents caused by Ag, Zn, Mo, Cd and Sb eliminated. Procedural blanks: 0.54 ± 0.21 ng (N = 3), recovery: 95–102%, (N = 32): External precision (δ120Sn) = 0.02–0.04‰ (N = 55). New δ117Sn, δ119Sn, δ120Sn and δ122Sn values for seven RMs: USGS BCR-2, USGS BHVO-2, USGS AGV-2, GSJ JG-2, GRPG AC-E, NRCC PACs-2 and IGGE GSS 7 | 405 |
| Sr isotopes | Standard glasses | — | LA/solution MC-ICP-MS/MS | Precision (RSD) of in situ87Sr/86Sr and 87Rb/86Sr isotope ratios (NIST SRM 610, BCR-2G, BHVO-2G, and OJY-1) = 0.016%–0.036% | 348 |
| Sr isotopes | Apatite | Four grains per sample, LA | LA- ICP-MS | In situ 87Sr/86Sr precision 0.45‰ (2SD) at 13 µm scale | 406 |
| Ti isotopes | Zircon RMs | LA-ICP-MS/MS | NH3 used to remove 48Ca+ and 96Zr2+ interferences on 48Ti+. Analytical precisions <10%. Use of O2 proved unsuitable due to 48Ca16O formation | 407 | |
| U–Pb dating | Columbite | Epoxy mounts | LA-MC-ICP-MS | Resolution 10 µm (improved vs. >20 µm). 206Pb/238U ages correlated with Ta/(Nb + Ta) ratio | 408 |
| (U–Th)/He dating | Vesuvianite | Fragmentation, encapsulation | Laser He stripping-MS, ICP-MS | First vesuvianite (U–Th)/He dating. Ages consistent with U–Pb. Seven natural samples analysed: five alkaline rocks from China, a calcic grossular Al garnet (Russia) and metapelites (Mexico). Determined weighted mean ages: China M6635, 225.0 ± 4.0 Ma; M784, 223.0 ± 4.8 Ma; M1377 : 216.8 ± 4.0 Ma. ± 4.7 Ma; M6608, 89.2 ± 2.8 M; M1439, 165.1 ± 3.7 Ma; Russia, Wilui, 266.7 ± 6.6 Ma; Mexico, Bufa, 32.3 ± 0.6 Ma |
409 |
| Zn isotopes | Granodiorite, andesite, diabase, basalt, manganese nodules, granite | Precipitation + AG1-X8 chromatography | MC-ICP-MS | USGS GSP-2 (granodiorite), USGS AGV-2 (andesite), USGS W-2 (diabase), USGS BCR-2 (basalt), USGS BHVO-2 (basalt), USGS NOD-A-1 (manganese nodule), NCRM CRMs GBW07103 GSR-1 (granite), GBW07104 GSR-2 (andesite), and GBW07105 GSR3 (basalt). δ66Zn for 9 RMs consistent with literature. δ66ZnJMC-Lyon = 0.01‰–0.09‰ (2SD). Zn recovery around 98% | 410 |
| Zn isotopes | Basalt, andesite, manganese nodules, granodiorite | AG1-X8 resin purification | MC-ICP-MS | Zn recoveries ∼98%. δ66/64ZnJMC Lyon: −1.43 ± 0.04‰ (2SD, N = 362) for NIST SRM 3168a, 0.29 ± 0.04‰ (2SD, N = 61) for IRMM 3702 and 0.29 ± 0.04‰ (2SD, N = 61) for AA-ETH-Zn. Long-term external reproducibility: ±0.04‰ (2SD) | 411 |
| Zr isotopes | Basalt | DGA resin single-pass chromatography | MC-ICP-MS | Results for eight RMs consistent with literature. Long-term reproducibility <±0.048‰ for δ94Zr | 412 |
| Analytes | Matrix | Technique | Sample preparation method | References |
|---|---|---|---|---|
| Ru, Os, Pd, Rh, Ir, Pt | Geological RMs | ID-ICP-MS | NaOH–Na2O2 fusion; HNO3 acidification; K2S2O8 oxidation; HF/HCl dissolution; Te co-precipitation | 413 |
| Re, PGE | Meteorites | LA-ICP-MS | Comparison of carius tube and high-pressure ashing (HPA) dissolution; cation exchange column for on-line separation | 414 |
| Pd, Rh, Ir, Pt | Ore samples (PGE-bearing) | LA-ICP-MS | Sb fire assay preconcentration; compared to Pb-, NiS-, and Bi-based fire assays | 415 |
| Cd | Meteorites and soils | MC-ICP-MS | Digestion; AG MP-1M resin column in HCl; microcolumn purification | 129 |
| Nd, Sm | Chondrite | TIMS | Sequential ion-exchange (AG1-X8, TRU-Spec, DGA resins) | 416 |
| Sn | Siliceous rocks | MC-ICP-MS | Double-spike method; rock dissolution; organic matter removal; two-stage ion-exchange | 374 |
| REE (heavy REE focus) | Barite-bearing minerals | ICP-MS | Triethanolamine extraction; ammonia precipitation; anion exchange chromatography (717 resin) | 417 |
| ZrIV | Digested soils and rocks | ICP-AOES | Micelle extraction using eriochrome cyanine R and CTAB; cloud point extraction with Triton X-114; EtOH:HNO3 dissolution | 323 |
| Hg | Carbonates (corals, speleothems, carbonate rocks) | MC-ICP-MS | Digestion–reduction–purge–trapping protocol | 418 |
An automated double-layer quartz pyrohydrolysis tube equipped with a liquid nitrogen cold trap was employed182 for the quantitative recovery of volatile halogen compounds from geological materials. The use of V2O5 promoted matrix decomposition and halogen volatilisation. After cold trapping, halogens were quantified by IC (Cl, F) and ICP-MS (Br, I) with MDLs of: 1.2 ng g−1 (Br), 0.40 µg g−1 (Cl), 0.25 µg g−1 (F), and 0.32 ng g−1 (I), for a 0.7 g sample. For the USGS RM BHVO-2 (Hawaiian volcano observatory basalt), Br Cl, and F results agreed with reported consensus values. However, iodine recoveries were significantly higher than the compiled reported values obtained with similar techniques, but agreed with those obtained using radiochemical NAA, demonstrating the efficacy of the extraction procedure.
Use of a novel dual-stage combustion-based system that incorporated an MnO2 catalyst improved183mercury isotope determination in ores by effectively releasing Hg0 and eliminating tellurium by promoting the formation of non-volatile MnTeO3. Unlike existing methods, which failed to remove tellurium, the new system improved Hg recovery (100.5 ± 3.8%, 1SD, N = 15) and reduced interferences during isotopic analysis of magmatic and hydrothermal sulfide ores by MC-ICP-MS.
Accurate quantification of amorphous inorganic phases in soils remains difficult with powder XRD. A comparative study184 tested two sample preparation methods using synthetic mixtures that were also analysed by XRF. In the conventional method, quartz–calcite–feldspar–clay mixtures were spiked with corundum (30% w/w) as IS and ground in ethanol, and the amorphicity was determined relative to the IS. In the alternative spray-drying method, aqueous suspensions with polyvinyl alcohol and 1-octanol produced fluid granules that could be analysed without sample rotation because samples were now more homogeneous. For mixtures with a >10% (w/w) amorphous content, both methods were accurate to <10%, the spray-drying method achieved better precision and eliminated orientation effects due to presence of clays.
Matrix effects continue to challenge LIBS quantification. The influence of moisture was investigated189 by evaluating spectral changes as rock samples were dried. It was determined that higher humidity attenuated spectral signals and their duration but without significantly affecting the plasma electron density or ionisation temperature. For U quantification in minerals, a modified spectral (internal) standardisation method utilised190 correlations with a matrix element, typically silicon, in combination with a dominant-factor PLS regression model to improve the analytical signal RSD from 23% to 9% and improved r2 from 0.91 to 0.99.
An innovative direction for overcoming matrix effects is the measurement191 of the acoustic emissions from laser-induced plasmas as a diagnostic signal using microphones. It was shown that, at laser fluences above the breakdown thresholds, acoustic responses were identical across various matrices, whereas at low fluences, the acoustic signal produced depended on the matrix and, hence, the normalisation of LIBS intensities to acoustic signals produced more consistent elemental determinations. Use of DP LIBS with acoustic signal normalisation for rock analysis significantly improved classification accuracy, from 91.8% when only using LIBS, to 97.3%. Use of a prototype portable LIBS system enabled192 the spatial distribution of Ti in quartz veinlets to be readily mapped in the field, although the results were semi-quantitative in nature because of the lack of matrix-matched RMs and optimised calibration algorithms. A drive for portability led to the development193 of a miniaturised prototype LIBS system with data processing tools such as PCA. The use of a SVM model achieved a 99.6% classification accuracy for 16 rock types studied. Similarly, a handheld system was used194 for the in situ mapping of iron meteorites that was superior to handheld XRF because low-atomic-number elements could be determined. Furthermore, improved compositional mapping using microspot analysis was available with which up to 40 elements could be measured.
Limitations in classifying rocks can be overcome by synergistic instrumental use. Here use of195 LIBS now enabled petalite to be distinguished from spodumene using knowledge of the matrices gleaned from prior examination of Raman spectral information. In another study, a similar fusion196 of LIBS and Raman data improved classification accuracy to 99.7% for 11 distinct mineral types. Femtosecond LIBS minimises plasma thermal effects within the ablation zone compared to those created by ns laser pulses, thus leading to improvements in measurements. In an exploratory study, Mg/Ca and Sr/Ca ratios determined in a Himalayan stalagmite197 tallied with δ13C and δ18O data thus validating the technique as a promising tool for high-resolution paleoclimatology. The performance of ns-LIBS and fs-LIBS for quantifying U and Th in twelve tantalum-niobium ores was compared198 and benchmarked against reference measurements undertaken using HPGe-γ spectrometry. Based on parameters such as the goodness of calibration fit and measurement precision, use of fs-LIBS was deemed superior.
Novel sample manipulation techniques were applied to the interrogation of mineral particles by LIBS. Use199 of an optical catapulting and trapping approach LIBS (OC–OT-LIBS) enabled individual meteorite particles to be suspended and analysed. The use of ternary plots enabled mineral phases to be differentiated and the application of calibration-free LIBS enabled semi-quantitative oxide compositions to be obtained. In the on-line analysis of powdered coal,200 a cylindrical sample confinement system improved particle flow stability, and the use of a relative S/N measurement approach enhanced the accuracy of proximate analysis models.
Planetary science remains a major LIBS application area. Under simulated lunar vacuum conditions of ca. 100 to 400 mTorr, it was demonstrated201 that whilst LIBS was able to quantify 69 elements in pulverised and pelletised terrestrial rock standards, achievable LOQs for Br, C, K2O, Rb and S were higher than typical concentrations present in Moon rock. Cross-calibration transfer approaches were proposed202 for determining major element compositions across Earth, Mars, and Moon matrices that are impacted by different atmospheric conditions. On missions to Mars, harmonisation203 of LIBS data from the ChemCam and MarSCoDe rovers was achieved by cross-instrumental spectral harmonisation and peak position consistency correction protocols. This reduced average intensity differences and peak wavelength differences while lowering rsmes for oxide prediction.
For U–Pb zircon dating by LA-MC-ICP-MS, the influence of ablation spot size (35–10 µm) and laser shot replicates(50–150) on downhole fractionation (DHF) precision and accuracy was assessed.204 Fewer repetitive shots improved 206Pb/238U accuracy by reducing standard-sample fractionation, especially for small spots. Method performance was benchmarked using the IAG 91500, GJ-1 and the Plesovice Princeton University zircon RMs. By using a 15 µm spot size with 150 laser shot replicates, the variation in DHF(206Pb/238U) between IAG 91500, taken as primary standard, and GJ-1 and Plesovice, taken as samples, was determined to be ca. 13%, and the ages were found to agree to <1.5% of the consensus values, but lowering the shot number to 50 reduced the DHF variation to ca. 2.4%, and improved age accuracy to <1%.
Simultaneous determination of U isotopic composition and particle age was demonstrated205 in U-containing microparticles using LA-MC-ICP-MS where the isotopic composition was derived from 234U, 235U, and 238U abundances with dating derived from 230Th/234U measurements. Evaluation of the method using U particles of varying age and isotopic composition, produced results consistent with those obtained using LG-SIMS but highlighted a need for standards to correct for Th/U fractionation.
Improvements in dating applications were attributed to optimisation of sample preparation steps. Both thermal annealing and chemical abrasion procedures can impact206 zircon U–Pb dating by LA-ICP-MS, especially in ancient (∼4.0–3.8 Ga) complex zircons. Post-annealing CA improved concordance and reduced scatter, while TA enhanced sample homogeneity. It was determined that HF leaching at 170 °C efficiently removed radiation-damaged zones and annealing partially repaired damage, but neither process altered Lu–Hf IRs or trace element compositions and enabled a better matching between samples and standards. In a related study,207 the CA impact on zircon U–Pb ages, O isotopes, and trace elements composition were examined using SHRIMP and LA-ICP-MS when it was determined that U–Pb ages from untreated RMs were systematically younger than those from CA-treated samples; whereas, isotopic compositions were unaffected, but some trace element variations were observed. A novel in situ triple-dating protocol208 combined the use of U–Pb, (U–Th)/He, and fission track methods on single apatite crystals thus enabling three independent age verifications. Apatites were mounted in a polymeric film, sectioned, and polished to ensure homogeneity. Improvements, included use of pit depth rather than volume in (U–Th)/He dating and optimal use of etching, demonstrated potential for resolving thermal histories and provenances with greater efficiency and higher spatial resolution.
A new low-cost sample preparation system for radiocarbon dating employed209 Zn as a reducing agent and Fe powder as a catalyst to convert CO2, generated from samples, to graphite. Capable of handling diverse sample matrices (organic matter, carbonates, water), the system achieved conversion efficiencies of 50–100% thus providing accurate AMS results even for very low-carbon containing samples of ≤0.01% (m m−1), such as arid or agricultural soils.
The attributes of the prototype CC-MC-ICP-MS/MS Proteus were exemplified212 through the in situ LA determination of Ti in stardust. Benefits of one configuration included the exclusion of undesirable ions such as Ar+ from the CC using a mass filter with improved resolution and a mass-shift protocol to avoid isobaric interferences.
Micro-ultrasonic single-droplet nebulisation 213 was used in the determination of δ7Li in a basalt RM by MC-ICP-MS. Ultra low sample volumes of only 0.5–8 µL were deposited on a nebulizer foil and aerosolised, generating transient signals that lasted seconds but producing data comparable to that obtained with more conventional nebulisation. Benefits included reduced washout times, a 17-fold sensitivity enhancement, improved long-term precision with a sample mass requirement of only ca. 1 ng.
Use of LA-ICP-MS is advantageous for spatially-resolved trace element mapping. Using a numerical inversion method that involved214 fitting, deconvolution, regularization, and boundary restoration, spatial resolution was improved ca. 18-fold compared to original data interrogation so improving the analysis of barite, pyrite, apatite, and zircon samples. High-resolution 2D geochemical imaging of biogenic carbonates was achieved215via LA-TOF-ICP-MS at a 1–2 µm pixel resolution and a mapping rate of 200 pixels per s enabled microscale variability in Ba, Mg, Sr and U to be determined in coral skeletons, coralline algae, and foraminifera. The technique provided both cost- and time-effective alternatives to synchrotron X-ray spectroscopy, SIMS, and EMPA.
The typically low I to Ca ratios found in carbonate rocks were more readily determined216 with a SCGD sample introduction system coupled to ICP-MS. This enhanced the I signal 100-fold and decreased the Ca signal 70-fold compared with those of conventional nebulisation, thus improving accuracy and precision.
The use of nanoSIMS has revealed significant isotopic heterogeneity at the micrometer scale in pyrites. Individual Ediacaran pyrite grains, previously assumed to be homogeneous, displayed219δ34S variations of up to 69.3‰ over a 1–5 µm scale thus highlighting the need for analysis at high spatial resolution for a better understanding of ancient biogeochemical processes. The interrogation of Archean sedimentary pyrite grains with a 0.2 µm Cs+ ion beam enabled220 a resolution of only 1 µm2 and a precision of ca. 1‰ (1SD) for δ34S measurements. An integrated nanoSIMS method for the simultaneous measurements of O isotope ratios and volatile components (Cl, F, H2O, SO3) in apatite was reported221 at a lateral resolution of ∼7 µm following optimisation of detector configuration, raster area, and primary beam current. While oxygen isotope data was less precise relative to that obtainable by LG-SIMS, total spot measurement time was only ca. 6 min, and LODs were sufficiently low to quantify volatiles at ppm levels. Analyses of eight apatite RMs produced results consistent with published data. A high-spatial-resolution methodology for Mg isotope determinations in olivines at the micrometer scale incorporated222 online correction of both matrix and fractionation effects using an empirical model based on the use of the so-called BiHill equation. When applied to the analysis of lunar olivine samples from the Chang’e-5 mission, δ26Mg variations exceeding 4‰ over distances of <100 µm were revealed.
Stable carbon isotope measurements in basaltic glasses were determined223 after meticulous optimisation of LG-SIMS protocols. To minimise volatile carbon contamination, samples were typically degassed under vacuum overnight. Method blanks were quantified using carbon-free olivine, and corrections applied for any residual organic blank contributions. The 12C− and 13C− ions were measured simultaneously by EM detectors, whereas reference masses (30Si− or 18O−) were collected by a 1011 Ω Faraday cup. Internal drift was corrected on a per-analysis basis, while external drift was addressed through frequent analysis of RMs. Achievable internal precision for δ13C measurements was ±0.35‰ (1RSE) at sample concentrations of 1706 µg g−1 (expressed as a CO2 equivalent content) and ≤±1.00‰ or better for concentrations between 163 and 267 µg g−1.
In a comparative study224 for the determination of S isotopes in a natural marcasite sample, minor discrepancies of <1.5‰ between SIMS and LA-MC-ICP-MS and GS-IRMS measurements were observed but were not attributable to crystal orientation effects in SIMS measurements, which hitherto had not been unexplored.
A WD-XRF protocol for gold quantification in geological matrices such as rocks and soils involved226aqua regia digestion, evaporation to dryness, and subsequent WD-XRF measurement. So avoiding the environmental and safety hazards associated with the more common lead oxide fire assay or MIBK solvent extraction. The LODs were 20–70 µg kg−1 using gold-enriched hematite standards as calibrants. Results were in good agreement with those obtained by fire assay coupled with ETAAS, and analyses of two USGS CRMs demonstrated acceptable accuracy according to the AOAC guidelines.
A new approach for quantitative TXRF analysis227 of complex matrices, such as oceanic polymetallic nodules, addressed the problem of spectral overlaps by using LS deconvolution of measured spectra into weighted sums of simulated elemental subspectra. This was advantageous because use of only one matrix-matched reference standard was now required. Comparative evaluation against an external calibration approach with IS correction for 11 elements demonstrated the accuracy of the new method, particularly when calibration materials are limited.
X-ray computed tomography quantitative mineral mapping at the nanoscale has been advanced228 by the development of a mathematical model exploiting the linear relationship between X-ray attenuation and elemental concentration and applying Bayesian decision theory to match voxel-wise attenuation to reference attenuation distributions from pure mineral standards. The algorithm assigns the most probable composition to each voxel thus enabling high-resolution 3D mineral maps to be constructed. Application of this approach to binary (Ca, Cd)CO3 and ternary (Ca, Cd, Zn)CO3 test carbonates demonstrated accurate mineral identification and mapping.
Fusion of NIR and XRF spectral information has emerged as a powerful approach for classifying229 coal quality. An initial SVM model was used to identify coal type prior to use of PLS regression for predicting ash, volatile matter, and sulfur content, resulting in a classification accuracy of up to 96%. A similar fusion approach was deployed230 on an integrated coal analyser system enabling rapid and automated coal classification, improved repeatability, reduced analysis time, enhanced safety, and better detection of sub-standard coal compared with the performance of conventional approaches.
The first application of a neural network (NN) for the quantification231 of homogeneous bulk samples by confocal µ-XRF significantly simplified data evaluation and effectively eliminated the need for human intervention, requiring no equipment characterization, elemental selection, deconvolution, or initial parameters. The NN training relied on simulated data derived from the elemental compositions of CRMs stored in the GeoReM database. The model predicted sample densities within ±30%, with spatial accuracies within ±10 µm. While accuracy was marginally lower than that of conventional FP approaches, processing speed increased by ca. 105, and eliminated the need for instrument-specific calibrations or deconvolution protocols.
The hierarchical convolutional network with attention excitation (HCNAE) architecture was designed232 for elemental analysis of minerals by XRF. This approach improved resilience to matrix effects, line interference, and instrumental noise. Comparative tests demonstrated superior predictive accuracy and robustness relative to those of conventional machine and deep learning models.
In the classification233 of vanadiferous titanomagnetite ore rock by XRF, the performances of six supervised models, namely SVM, RF, extreme gradient boosting (XGBoost), light gradient boosting machine, DNN and 1D-CNN were evaluated. Use of the 1D-CNN model delivered the best predictive accuracy, underscoring its potential to enhance operational efficiency in underground mining.
The use of N2 as an ablation and transport gas in LA-microwave-sustained inductively coupled atmospheric-pressure plasma mass spectrometry (MICAP-MS) was compared235 with He and Ar in the analyses of geological RMs. Parameters such as sensitivity, quantification capability, and particle size and morphology under different laser conditions and cell geometries were evaluated. Nitrogen was found to be a cost-effective alternative despite the differences seen in aerosol morphology and transient signal profiles. The use of Al cones instead of Pt further reduced operational costs.
An improved TIMS instrument employed236 a dual-focusing Nier–Johnson geometry with improved ion energy control, transmission efficiency, and mass resolution. Furthermore, an advanced symmetrical five-electrode retarding filter provided both energy and directional filtering, thereby reducing peak tailing and improving abundance sensitivity from <2 ppm to <5 ppb. A detector array consisting of 16 FCs and 4 discrete dynode secondary EMs with double quadrupole zoom lenses enabled simultaneous collection of multiple isotopes with precisions <4 ppm. Use237 of a MoSi2 emitter enhanced Cd ionization efficiency enabling a reduction in the required sample mass from 100 ng to only 6.5–9 ng whilst maintaining a precision of ±0.051‰ (3 ng Cd, 2SD) in δ114/110Cd measurements of NIST SRM 3108 (cadmium standard solution).
In a matrix-assisted ionisation TOF-MS method for rapid U isotope ratio determination238 the addition of 3-nitrobenzonitrile to samples in 2% HNO3 generated volatile uranyl trinitrates 235UO2(NO3)3− or 238UO2(NO3)3− under vacuum, allowing analyses to be performed within minutes eliminating the need for sample purification. Enrichment differences as small as 0.2–0.3% were resolved in solutions that contained only 200–500 pg U.
Determination239 of Pb and trace element isotope ratios in glass and zircon RMs using an improved LA-VUV-TOF system enabled 207Pb/206Pb and 208Pb/206Pb precisions of <1.6% (2SD), matching ID-TIMS values. Other advantages included ablation spots of ≤2 µm compared to >20 µm for LA-ICP-MS and 5–10 µm for SIMS, high sensitivity, stability, calibration-free operation, and no requirement for metallic sample coatings.
Sample preparation guidelines for high-precision CF-IRMS analysis of δ13C and δ18O in calcite, dolomite, and magnesite were issued240 following optimisation of the acidification step to release CO2. The influence of mineral grain size, reaction temperature, and time on CO2 production were studied to reduce non-equilibrium isotope effects and 18O exchange with water. Time-resolved evolution of phosphoric acid–released CO2 confirmed δ18OCO2 drift was unavoidable.
A V-shaped cavity optical feedback/cavity ring-down spectroscopy (CRDS) instrument deployed241 for O isotope ratio measurements in water and carbonate RMs used a stabilised near-IR laser diode in a low-pressure V-shaped cavity, with acousto-optical wavelength modulation, thus providing 0.004‰ precision in Δ′17O measurements within 10 min. Measurements with this technique then allowed robust linking of VSMOW-SLAP and VPDB scales by providing updated O isotope values for NBS and IAEA carbonate standards.
The matrix effects in SHRIMP-stable isotope analysis242 were corrected by using LA-ICP-MS elemental data. In the triple O isotope analysis of stony micrometeorites, removal of IMF using San Carlos olivine (δ18O = 5.27‰) improved δ18O and δ17O values. This combined with LS modelling of idealised olivine-basaltic glass-iron oxide mixtures improved δ18O accuracy, so results for East Antarctic cosmic spherules agreed with those of prior bulk method.
The determination243of Li isotope ratios in geological samples by HR-CS-AAS utilised the 15 pm wavelength difference between the 22P ← 22S transition at 670.8 nm to resolve 6Li from 7Li. Data analysis using extreme gradient boosting ML algorithms available in the open source XGBoost software, yielded δ7Li precisions of 1.0–2.5‰ at an instrumental resolution of λ/Δλ ≈ 7
80
000, for samples with δ7Li values ranging from ±0.5 to 4.5‰, these results were not significantly different compared to MC-ICP-MS data.
The quantification of REEs, Th and U by k0-NAA in Egyptian monazite sands was hampered244 by neutron self-shielding. This was alleviated by sequential sample dilution using SiO2 to derive an empirical correction factor from exponential fitting of mass-specific count rates versus diluted values. This protocol was validated using a synthetic monazite and comparative analysis with ICP-MS. The authors noted that the advantages were that their procedure avoided a priori compositional knowledge and yielded negligible spectral/nuclear interferences or γ self-attenuation effects.
Use of both TOF-SIMS and resonant laser secondary neutral mass spectrometry (rL-SNMS) facilitated245 the mapping of Pu diffusion in Opalinus clay where the latter technique, despite its lower intensities, confirmed the 242Pu+ distributions obtained by TOF-SIMS. The Pu in the pore water occurred mainly as PuO2+, as verified by CE-ICP-MS and displayed a lower mobility than those of other actinides under similar conditions.
An EPMA protocol for accurate N quantification in silicate and oxide minerals and glasses was proposed246 whose use of multipoint background corrections and a peak area factor improved accuracy. Improvements included optimisation of beam parameters to limit N mobility and use of Python scripts for community adoption. The use of nitrides such as BN or GaN as RMs was recommended.
Calibration247 of a spatially resolved scanning transmission electron microscopy-mapping electron energy loss spectroscopic (STEM-EELS) procedure enabled Fe3+ determination at submicron scales in materials such as hornblende, magnetite, and hematite for the first time. A correlation between Fe-L3/L2 peak area ratios and Fe3+/ΣFe was established using pyroxene RMs. Recommended optimal sample thickness and instrumental parameters (residence and integration time) were presented.
The first application248 of photon counting computed tomography (PC-CT) to mineralogical investigations as an alternative to conventional attenuation-contrast X-ray CT was reported. The authors built a prototype PC-CT with multi-pixel photon counters that demonstrated improved low-energy contrast versus that of traditional CT when quartz and calcite were interrogated as model mineral phases. Outcomes suggested that the production of high-contrast images of minerals was feasible, thus enabling mineral phases with different attenuation curves to be distinguished, even when their CT values are similar.
Recent analytical advancements that focus on integrating diverse techniques with sophisticated chemometrics and ML for enhanced geological analysis are summarised in Table 14. Notably LA-ICP-MS data processing has seen improvements through platform-independent web applications250 and open-source Python packages251 to increase calibration flexibility and computational efficiency. As reported within, techniques like LIBS and XRF now utilise231,232 DL models for rapid, accurate 3D elemental quantification and robust heavy-metal analysis. Furthermore, combining multimodal data (e.g., LIBS + Raman, pXRF/hyperspectral/wireline)252 with chemometric models (e.g., PCA, PLS) or knowledge distillation frameworks improves mineral classification, boundary detection, and source rock characterization. This integration yields superior precision and interpretability across various geological samples, including regolith, gold grains, and apatite.
| Analytes and/or sample | Algorithm or software | Technique | Comments | References |
|---|---|---|---|---|
| Apatite | Integrated open-source fission track software (Trax®) | LA-ICP-MS with fission track analysis | New LA-ICP-MS protocol for apatite dating using Trax® software integrates fission track length measurements with mineral geochemistry. Ages derived from modified xi calibration approach, ξICP (U/Ca-based), and absolute U calibration match EDM results on RMs | 419 |
| 40 elements in Regolith and parent rock materials | DataMosaic™ + user-supervised algorithm (uTSA) + multi-feature extraction methods (MFEMs) | pXRF, VNIR–SWIR hyperspectral, wireline logging, including natural gamma, inductive conductivity, and magnetic susceptibility | Multivariate ML and wavelet-based framework combining hyperspectral, geochemical and petrophysical data for boundary detection | 252 |
| Enabled more precise delineation of regolith boundaries and internal zoning than manual or geochemical-only methods | ||||
| Signals were measured for 47 m/z ratios in tungstates and silicates (scheelite and garnet) | G.O.Joe platform independent web application | LA-ICP-MS | Dart-based browser application for LA-ICP-MS data processing including multi-step correction workflow | 250 |
| Improved correction accuracy, data quality, and consistency in multi-elemental analysis of geological materials | ||||
| General LA-ICP-MS datasets | ICPMSDataCal-Py | LA-ICP-MS | Python open-source package with scalable calibration and isotopic formula editor | 251 |
| Enhanced computational efficiency and flexible calibration across isotopic systems | ||||
| Gold grains (trace element analysis) | OreGenes (MATLAB) | Geochemical analysis of gold grains | Neural network-based classification using PCA-selected elements for deposit-type prediction | 420 |
| Accurately classified gold deposit types and linked trace elements to structural defects | ||||
| General applications | Hklhop, open-source software package | Hard X-ray samples using spherically curved crystal analysers (SBCAs) | Python tool for asymmetric Rowland circle configuration optimisation of SBCAs | 421 |
| Reduced Johann broadening and increased operational flexibility while lowering costs | ||||
| Meteorite and geological samples | TOFHunter | ICP-TOF-MS | Python package using PCA and interesting feature finder (IFF) for unbiased data exploration | 422 |
| Revealed key elemental correlations and interferences without prior compositional knowledge | ||||
| Homogeneous solid samples | CNN–MLP model | CMXRF | AI-based approach combining CNN feature extraction with MLP prediction trained on simulated data | 231 |
Achieved 3D quantification of 53 elements with <30% deviation and 1 000 00× faster than traditional models |
||||
| Minerals containing Cu, Zn, Pb | Hierarchical convolutional network with attention excitation | XRF | DL model integrating convolutional layers with Squeeze-and-Excitation attention mechanism | 232 |
| Outperformed existing ML/DL models in heavy-metal quantification accuracy and robustness | ||||
| Zircon (O isotopes), RMs (S isotopes) | CSIDRS open-source software | SIMS | Software using Monte Carlo uncertainty propagation for isotope data reduction | 423 |
| Provided higher precision and reproducibility than spreadsheet-based reduction methods | ||||
| Source rock samples (76) | Multi-block chemometric model (PCA, PLS, HPLS) | NIR, FT-Raman, XRF | Hierarchical data integration and variable selection via VIP scores for spectral data fusion | 424 |
| Produced improved unsupervised clustering and interpretability of rock source classification | ||||
| Lithium-bearing minerals, e.g. quartz–amblygonite, albite–lepidolite–zinnwaldite | LIBS clustering algorithm | LIBS | Baseline removal, Gaussian filtering and k-means clustering for mineral discrimination | 425 |
| Successfully identified complex mineral assemblages validated against petrographic analysis | ||||
| Iron ores (by grade/origin) | DP-LIBS classification (PCA + k-means) | DP-LIBS | Multivariate approach combining PCA and k-means for unsupervised clustering of spectral data | 426 |
| Achieved >94% classification accuracy by grade and origin using atomic and molecular emissions | ||||
| Multielemental LIBS spectra | Semi-automated elemental identification algorithm | LIBS | Comb-shaped spectral filter-based algorithm for semi-supervised qualitative analysis | 427 |
| Enabled autonomous interference detection and improved reliability of elemental assignment | ||||
| Li-bearing minerals (e.g. petalite, spodumene) | Multimodal spectral knowledge distillation (LIBS + Raman) | LIBS + Raman | Knowledge transfer framework aligning Raman (teacher) and LIBS (student) models | 195 |
| Improved classification accuracy for spectrally similar lithium minerals | ||||
| Polymetallic nodules | GANN with physics-based loss | LIBS | Augmenting limited LIBS datasets | 428 |
| Improved predictive accuracy for Ni, Co and Li quantification compared to baseline ML models | ||||
| LIBS and Raman spectra for mineral classification | Adaptive nonlinear mapping (CNN-based image classification) | LIBS + Raman | Feature extraction via intensity, width, and area conversion into 2D image representation | 196 |
| Achieved 99.7% accuracy and superior performance compared with PCA and RF approaches |
| 3D | three dimensional |
| AAS | atomic absorption spectrometry |
| ABS | acrylonitrile butadiene styrene |
| AEC | anion-exchange chromatography |
| AES | atomic emission spectrometry |
| AFM | atomic force microscopy |
| AFS | atomic fluorescence spectroscopy |
| AI | artificial intelligence |
| AMS | accelerator mass spectrometry |
| AMU | atomic mass unit |
| APA | automated particle analysis |
| APGD | atmospheric pressure glow discharge |
| APM | atmospheric particulate matter |
| BAM | Federal Institute for Materials Research and Testing (Germany) |
| BP-ANN | back propagation-artificial neutral network |
| BPNN | backpropagation neural networks |
| C18 | octadecyl bonded silica |
| CA | chemical abrasion |
| CC | collision cell |
| CCD | charge coupled device |
| CCT | collision cell technology |
| CE | capillary electrophoresis |
| CF | continuous flow |
| CFD | computational fluid dynamics |
| CF-IRMS | continuous-flow isotope ratio mass spectrometry |
| CI | confidence interval |
| CIMS | chemical ionisation mass spectrometry |
| CISH | cross-instrument spectral harmonisation |
| CMOS | complementary metal oxide semiconductor |
| CMPO | octyl(phenyl)-N,N diisobutylcarbamoylmethylphosphine oxide |
| CMXRF | confocal micro-XRF |
| CNN | convolutional neural network |
| CNPGAA | cold neutron prompt gamma activation analysis |
| CPE | cloud point extraction |
| CRC | collision/reaction cell |
| CRCCRM | Chinese Research Centre for Certified Reference Materials |
| CRDS | cavity ring-down spectroscopy |
| CRM | certified reference material |
| CS | continuum source |
| CT | computed tomography |
| CTAB | cetyltrimethylammonium bromide |
| CV | cold vapour |
| CVG | chemical vapour generation |
| CyTOF | cytometry by time of flight |
| D50 | particle size at which there is a 50% collection efficiency |
| DBSCAN | density-based clustering of applications with noise |
| DECT | dual-energy computed tomography |
| DES | deep eutectic solvent |
| DF-PLSR | dominant factor-based partial least squares regression model |
| DHF | downhole fractionation |
| DL | deep learning |
| DLLME | dispersive liquid–liquid microextraction |
| DMA | dimethylarsenic |
| DNN | deep neural network |
| DP-LIBS | double-pulse laser-induced breakdown spectroscopy |
| DPTA | diethylenetriaminepentaacetic acid |
| EA | elemental analyser |
| EC | environment Canada |
| ECCC | environment and climate change Canada |
| ED | energy dispersive |
| EDM | external detector method |
| EDS | energy dispersive spectrometry |
| EDTA | ethylenediaminetetraacetic acid |
| EDXRF | energy dispersive X-ray fluorescence |
| EF | enrichment factor |
| ELPI | electrical low pressure impactor |
| EM | electron multiplier |
| EMS | exospheric mass spectrometer |
| EPA | environmental protection agency (USA) |
| EPMA | electron probe microanalysis |
| ERDA | elastic recoil detection analysis |
| ERM | European Reference Material |
| ESI | electrospray ionisation |
| ETAAS | electrothermal atomic absorption spectrometry |
| ETMAS | electrothermal molecular absorption spectrometry |
| EtOH | ethanol |
| FAAS | flame atomic absorption spectrometry |
| FC | faraday cup |
| FFF | field flow fractionation |
| FHP | fast hot-pressing |
| FWHM | full width at half maximum height |
| GANN | generative adversarial neural network |
| GC | gas chromatography |
| GeoPT | International Program for Professional Testing of Geoanalytical Laboratories |
| GOM | gaseous oxidised mercury |
| Grad-CAM | gradient-weighted class activation mapping |
| GS-IRMS | gas-source isotope ratio mass spectrometry |
| GSJ | Geological Survey of Japan |
| GSR | gunshot residues |
| HCNAE | hierarchical convolutional network with attention excitation |
| HG | hydride generation |
| HI | hyperspectral imaging |
| HPA | high-pressure ashing |
| HPGe-γ | high-purity germanium γ-ray |
| HPLC | high performance liquid chromatography |
| HPLS | hierarchical partial least squares |
| HR | high resolution |
| HTC | high-temperature conversion |
| IAEA | International Atomic Energy Agency |
| IC | ion chromatography |
| ICP | inductively coupled plasma |
| ICP-AES | inductively coupled plasma atomic emission spectrometry |
| ICP-MS | inductively coupled plasma mass spectrometry |
| ICP-TOF-MS | inductively coupled plasma time of flight mass spectrometry |
| ID | isotope dilution |
| ID-TIMS | isotopic dilution thermal ionization mass spectrometry |
| IEC | ion exclusion chromatography |
| IFF | interesting feature finder |
| IGGE | Institute of Geophysical and Geochemical Exploration |
| ILC | interlaboratory comparison |
| IMF | instrumental mass fractionation |
| INAA | instrumental neutron activation analysis |
| IR | isotope ratio |
| IRMS | isotope ratio mass spectrometry |
| IS | internal standard |
| ISO | International Organization for Standardisation |
| JNA | Johann normal alignment |
| KNN | k-nearest neighbour |
| LA | laser ablation |
| LABQ3 | linear attenuation Bayesian quantitative 3D-mapper |
| LAMIS | laser ablation molecular isotopic spectrometry |
| LASMA-LR | laser-ionisation mass spectrometer – low resolution |
| LDA | linear discriminant analysis |
| LF-IRMS | laser fluorination isotope ratio mass spectrometry |
| LGBM | light gradient boosting machine |
| LG-SIMS | large-geometry secondary ion mass spectrometry |
| LIBS | laser-induced breakdown spectroscopy |
| LIF | laser-induced fluorescence |
| LIMAS | laser ionisation mass analyser |
| LIPAc | laser induced plasmas acoustic signals |
| LLE | liquid–liquid extraction |
| LLME | liquid–liquid microextraction |
| LOD | limit of detection |
| LOQ | limit of quantification |
| LPME | liquid phase microextraction |
| LS | least squares |
| MAD | microwave-assisted digestion |
| MAE | microwave-assisted extraction |
| MC | multicollector |
| MCE | mixed cellulose ester |
| MDL | method detection limit |
| MEMS | micro-electro-mechanical system |
| MeOH | methanol |
| MFEM | multi-feature extraction method |
| MICAP | microwave inductively coupled atmospheric-pressure plasma |
| MIP | microwave induced plasma |
| ML | machine learning |
| MLP | multilayer perceptron |
| MMA | monomethylarsenic |
| MMAD | mass median aerodynamic diameter |
| MMWCNT | magnetic multiwalled carbon nanotube |
| MNP | magnetic nanoparticles |
| MOF | metal–organic framework |
| MOUDI | micro orifice uniform deposit impactor |
| MP | microplastic |
| MPT | microwave plasma torch |
| MS | mass spectrometry |
| MS/MS | tandem mass spectrometry |
| MSWD | mean squared weighted deviation |
| MU | measurement uncertainty |
| µCT | microscale X-ray computed tomography |
| MWCNT | multi-walled carbon nanotubes |
| NAA | neutron activation analysis |
| NBS | National Bureau of Standards |
| Nd:YAG | neodymium doped yttrium aluminium garnet |
| NIES | National Institute for Environmental Studies (Japan) |
| NIMC | National Institute of Metrology of China |
| NIOSH | National Institute of Occupational Safety and Health (USA) |
| NIR | near infra-red |
| NIST | National Institute of Standards and Technology (USA) |
| NMIJ | National Metrology Institute of Japan |
| NN | neural network |
| NP | nanoparticle |
| NRA | nuclear reaction analysis |
| NRCC | National Research Council of Canada |
| NRCM | National Research Center for Certified Reference Materials (China) |
| NRMSE | normalised root mean square error |
| NTIMS | negative thermal ionization mass spectrometry |
| OC–OT-LIBS | Optical catapulting–optical trapping LIBS |
| OES | optical emission spectrometry |
| PCA | principal component analysis |
| PC-CT | photon counting computed tomography |
| PCM | phase contrast microscopy |
| PENS | personal nanoparticle sampler |
| PERI | potential ecological risk index |
| PET | polyethylene terephthalate |
| PGE | platinum group element |
| PIGE | particle induced γ-ray emission |
| PIXE | proton induced X-ray emission |
| PLI | pollution load index |
| PLS | partial least squares |
| PLSR | partial least squares regression |
| PM1.0 | particulate matter (with an aerodynamic diameter of up to 1.0 µm) |
| PM10 | particulate matter (with an aerodynamic diameter of up to 10 µm) |
| PM2.5 | particulate matter (with an aerodynamic diameter of up to 2.5 µm) |
| PMMA | poly(methyl methacrylate) |
| ppmv | part per million volume |
| PS | polystyrene |
| PSL | polystyrene latex |
| PS-MP | polystyrene microplastic |
| PT | proficiency testing |
| PTE | potentially toxic element |
| PTFE | polytetrafluoroethylene |
| PTR | proton transfer reaction |
| PVC | polyvinylchloride |
| PVG | photochemical vapour generation |
| pXRD | portable X-ray diffraction |
| pXRF | portable X-ray fluorescence |
| Py | pyrolysis |
| Q/SF | quadrupole or sector field |
| QA | quality assurance |
| QC | quality control |
| QCL | quantum cascade laser |
| QMS | quadrupole mass spectrometry |
| QT | quartz tube |
| RCS | respirable crystalline silica |
| REE | rare earth element |
| rf | radio frequency |
| RF | random forest |
| RL-SNMS | resonant laser secondary neutral mass spectrometry |
| RM | reference material |
| rmse | root mean square error |
| RSD | relative standard deviation |
| S/N | signal-to-noise ratio |
| SBCA | spherically bent crystal analyser |
| SBET | simplified bioaccessibility extraction test |
| SCGD | solution cathode glow discharge |
| SE | standard error |
| SEM | scanning electron microscopy |
| SES | spark emission spectroscopy |
| SF | sector field |
| SF-ICP-MS | sector-field inductively coupled plasma mass spectrometry |
| SFODME | solidified floating organic drop microextraction |
| SHM-IRMS | step-heating extraction and manometry combined with isotope ratio mass spectrometry |
| SHRIMP | sensitive high-resolution ion microprobe |
| SHRIMP-SI | SHRIMP stable isotope |
| SIMS | secondary ion mass spectrometry |
| SIMS-SSAMS | secondary ion mass spectrometry-single stage accelerator mass spectrometry |
| SLAP | standard light Antarctic precipitation |
| SN | solution nebulisation |
| sp | single particle |
| SPE | solid-phase extraction |
| SR | synchrotron radiation |
| SRM | standard reference material |
| SSB | standard sample bracketing |
| SSML | semi supervised machine learning |
| SVM | support vector machine |
| TA | thermal annealing |
| TCE | technology-critical element |
| TCEA-IRMS | thermal conversion elemental analyser combined with IRMS |
| TD | thermal desorption |
| TEM | transmission electron microscopy |
| TIMS | thermal ionisation mass spectrometry |
| TL | transfer learning |
| TOC | total organic carbon |
| TOF | time of flight |
| TXRF | total reflection X-ray fluorescence |
| UAE | ultrasound-assisted extraction |
| URE | ultra fine particle |
| UNDBD | ultrasound nebulization-dielectric barrier discharge |
| UPLC | ultra performance liquid chromatography |
| USGS | United States geological survey |
| USN | ultrasonic nebulizer |
| UTEVA | uranium and tetravalent actinides |
| uTSA | user-supervised algorithm |
| UV | ultra-violet |
| VALLME | vortex assisted liquid liquid microextraction |
| VCOF-CRDS | V-shaped cavity optical feedback/cavity ring-down spectroscopy |
| VG | vapour generation |
| VIP | variable influence on projection |
| VNIR–SWIR | visible, near-infrared, and short-wave infrared |
| VOC | volatile organic compound |
| VPDB | Vienna Pee Dee Belemnite |
| VSMOW | Vienna Standard Mean Ocean Water |
| VUV-TOF | vacuum ultraviolet laser ablation/ionization time-of-flight mass spectrometry |
| WD-XRF | wavelength dispersive X-ray fluorescence |
| WEPAL | Wageningen Evaluating Programs for Analytical Laboratories |
| XAFS | X-ray absorption fine structure |
| XANES | X-ray absorption near-edge structure |
| XGBoost | extreme gradient boosting |
| XRD | X-ray diffraction |
| XRF | X-ray fluorescence |
| XRFS | X-ray fluorescence spectroscopy |
| µ-APD | atmospheric microplasma discharge |
| µ-XANES | micro-X-ray absorption near edge structure spectroscopy |
| µ-XRF | micro X-ray fluorescence |
| This journal is © The Royal Society of Chemistry 2026 |