Open Access Article
Lenka Kotrchová
a,
Martina Nevoralováb,
Michaela Hrochováa,
Zdeněk Starýb,
Tomáš Etrych
a and
Libor Kostka
*a
aInstitute of Macromolecular Chemistry, Department of Biomedical polymers, Czech Academy of Sciences, Heyrovského nám. 2, 162 00 Prague 6, Czech Republic. E-mail: kostka@imc.cas.cz
bInstitute of Macromolecular Chemistry, Department of Polymer Processing, Czech Academy of Sciences, Heyrovského nám. 2, 162 00 Prague 6, Czech Republic
First published on 21st November 2025
Water-soluble polymers are extensively studied materials in the field of biomedical chemistry research. This study investigates the behavior of methacrylamide-based homopolymers and copolymers with linear, two-arm, and star-like structures in aqueous solutions. The research focuses on how the polymer structure affects its solution behavior. The study uses intrinsic and shear viscosity measurements to examine the influence of these structures on solution behavior at both molecular and macroscopic levels.
The solution behavior of macromolecules is strongly related to the compactness and shape of the polymer coil. These properties, determined at the molecular level, significantly impact the material's behavior at the macroscopic scale. From an application perspective, the solution behavior determines the potential use of macromolecules in human medicine or related fields. One issue is related to production and troubles arising from the formulation processes, such as the dissolution rate and the viscosity properties of stock solutions. Secondly, it emphasizes the biological availability of active pharmaceutical ingredients (APIs), where the compactness of polymer coils can affect their availability towards enzymatic reactions and nonspecific noncovalent interactions. Therefore, we studied in detail the solution behavior of linear and star-like polymers and the influence of their molecular weight and structure on solubility in aqueous buffers.
Intrinsic viscosity is the most relevant variable for describing the behavior of a polymer solution at the molecular level. This is because intrinsic viscosity reflects the true viscosity properties of a polymer molecule independently of its concentration in solution.10 It is used in various industries to describe a product's storage stability and quality. Intrinsic viscosity is also a relevant testing parameter in the pharmaceutical industry (e.g., for the molar mass determination of products such as sodium hyaluronate). As such, it is listed in several monographs of the EU Pharmacopoeia and US Pharmacopeia.11
Shear viscosity is one of the transport coefficients of liquids and describes the current of transverse momentum.12 Provided that it governs the macroscopic flow of liquids, it plays an essential role in treating flows in chemical engineering and other fields. In addition, the shear viscosity of a solution is often regarded as a measure of the rates of dynamic processes of solutes dissolved in the solvent. It is, therefore, important and interesting to understand the shear viscosity of liquids in terms of microscopic structure and intermolecular interaction.
![]() | ||
| Fig. 2 Conformation plot showing the dependence of the RMS radius of linear HPMA-based homopolymers on molecular weight. Orange – curve from the MALS detector; black – the fitted curve. | ||
We investigated the relationship between intrinsic viscosity and molar mass, along with the Mark–Houwink plots (MHPs), for all synthesized materials (see Fig. 3A). The solution behavior of HPMA homopolymers and copolymers containing 6 mol% of comonomer units based on Ma-Acap-NHNH-Boc, regardless of being protected or deprotected, was found to be similar to that of HPMA homopolymers (refer to SI Fig. S6). The calculated slopes of the Mark–Houwink plots for homo- and copolymers yielded a precise value of 0.65, confirming a random coil conformation for the copolymers as well.17 The consistent behavior of the HPMA copolymers suggests that they can maintain their solution behavior even when functional groups suitable for the attachment of biologically active molecules are present.
The random coil conformation behavior changes were not observed when the aromatic linker was employed in the two-arm structure (see the red dot in Fig. 3B). However, significant changes were observed when the polymer's structure was changed from linear to star-like.
Importantly, the star-like polymer structures with at least four arms exhibit different solution behavior than linear polymers of the same molecular weight. For details, see SI Tables S3 and S4. The number and length of the polymer arms strongly impact the solution behavior of the star-like polymers. The intrinsic viscosity of four-armed star-like HPMA polymers becomes independent of molecular weight, and the solution behavior of the material is close to that of a solid sphere for which the slope of the MHP acquires zero value. Nevertheless, the slope values for 4-armed star-like polymers with Mw < 100 kg mol−1 were slightly positive, being dependent on arm length, 0.14 for SC-SA (18 kg mol−1 polymer arms) and 0.18 for SC-LA (37 kg mol−1), respectively (see Fig. 3B). As the molar mass of the star-like polymers increases above 100 kg mol−1, the slope value changes to zero for both SC-SA and SC-LA (see Fig. 3C).
Based on the observation that linear fits work well for both linear and star-like polymers (SI Fig. S7), their size increases proportionally with molar mass, but at a slower rate for star-like structures compared to linear polymers. To determine the compactness of the polymer molecule, we can use the Rg/Rh ratio, which indicates shape and compactness. For linear polymers, this ratio is above one, indicating elongated particles. For both SC-SA and SC-LA polymers, this ratio is significantly below 0.77, which corresponds to a particle with a dense core decorated by long, sparse chains. Please refer to SI Fig. S8 for further details.
Understanding changes in the conformation of polymer molecules in solution is crucial for the in vivo application of the polymer and interpreting results from biological experiments. A few years ago, Etrych et al. published a paper describing the elimination rate of polymer carriers dependent on polymer molar mass and architecture.18 Based on the results, HPMA-based carriers are eliminated from the organism via the kidneys up to molar fractions of 69 kg mol−1 in the case of linear polymers and up to molar fractions of 53 kg mol−1 in the case of star-like carriers. Also, the cumulative urinary elimination of linear conjugates was two times higher than that of star-like polymers. These findings suggest that the flexibility and conformation of the polymer chain may play a crucial role in its suitability for biomedical applications.
The rheological behavior of the polymer solutions has been studied in a steady shear mode. All solutions prepared from polymers with different molecular weights show Newtonian behavior, i.e., the viscosity values are independent of the shear rate applied in the whole measured range. Flow curves of solutions containing the polymer with a higher molecular weight of 64.3 kg mol−1 are displayed in Fig. 4.
![]() | ||
| Fig. 4 Flow curves of polymer solutions with Mw = 64.3 kg mol−1 at 25 °C at various solution concentrations (10–35 wt%). Experiments were performed in duplicates (empty and filled marks). | ||
The absence of shear thinning implies that there are no intertwinings of polymer chains in the solutions. A small viscosity increase at high shear rates was observed in some measurements, particularly those at higher concentrations. This effect is caused by the evaporation of water during the measurement, and thus, it is considered a measurement artefact. The reproducibility of the measurements was very good, with differences between individual measurements lower than 10%.
To evaluate the effects of molecular weight and concentration on solution viscosity, values at a shear rate of 50 s−1 were selected. Fig. 5 shows these values on a log–log scale, which is commonly used to differentiate between dilute and semi-concentrated solutions. As anticipated, the viscosity of the solutions increases with polymer concentration and molecular weight. For linear polymers at lower concentrations, the dependencies can be accurately described by a linear function, with coefficients of determination R2 exceeding 0.99. At polymer concentrations greater than 25 wt%, the dependencies become significantly steeper. In this concentration range, linear fits still show reasonable accuracy, with R2 values between 0.96 and 0.99.
![]() | ||
| Fig. 5 Concentration dependence of shear viscosity for polymer solutions with different molecular weights (the straight lines are linear fits of the experimental values on a log–log scale). | ||
A critical concentration ccrit, at which the linear macromolecules in the solution begin to interact and thus cause a more significant increase in shear viscosity with concentration, was determined from the extrapolated linear fits of both concentration ranges. The critical concentration was close to 24 wt%, independent of the molecular weight of the dissolved linear polymers. This can be explained by the fact that in the given polymer–solvent system, the macromolecules at the same concentration occupy the same total hydrodynamic volume regardless of their size. However, the molecular weight of the dissolved polymer affects how the shear viscosity increases with concentration. At lower concentrations of up to 20 wt% of the polymer, where no or minimal interactions between polymer coils are expected, the viscosity increases more rapidly as the molecular weight rises. This can be seen in Fig. 6, where the slopes of the linear fits describing the concentration dependencies of viscosity are plotted as a function of polymer molecular weight. In contrast, no clear trend is observable at concentrations above the critical concentration, and viscosity increases similarly for all studied molecular weights of linear polymers.
Besides polymers with a linear structure, a polymer with a star-like architecture and a molecular weight of 400 kg mol−1 has been studied. In this case of the star-like polymer, no transition can be identified in the concentration dependence of shear viscosity. All measured data up to 35 wt% of the polymer, higher concentrations cannot be prepared due to insufficient solubility, correspond to a linear fit with R2 = 0.97 (Fig. 5).
Although the fit quality is somewhat poorer than that of linear polymers, the critical concentration of the star-like polymer, at which polymer molecules begin to interact in the solution, is shifted to higher values well above 30 wt%. This finding is expected because star-like macromolecules occupy smaller hydrodynamic volumes compared to linear ones (cf. Fig. S7 in the SI). The impact of different architectures of dissolved polymer chains is also illustrated in Fig. 6. The viscosity of solutions of a star-like polymer as a function of concentration increases with a slope of 3.83, which is significantly lower than expected for a linear polymer with the same molecular weight. The determined slope of 3.83 for the star-like polymer with 464.4 kg mol−1 actually corresponds to that of a linear polymer with a molecular weight of approximately 142 kg mol−1. For a linear polymer with the corresponding molar mass (464 kg mol−1), the theoretical slope value should be 8.6 (cf. Fig. 6, grey column). This finding reinforces the conclusion that the concentration dependence of shear viscosity sensitively reflects the hydrodynamic volume of dissolved polymer chains.
Rheological measurements confirmed that the concentrated solution up to 45 wt% exhibited Newtonian behavior. The viscosity values remained independent of the applied shear rate throughout the measuring range. The highly concentrated solutions can be stored and utilized immediately after dilution to the experimental concentration, making them advantageous for infusion applications. The critical concentration of the shear viscosity slope, calculated to be approximately 24 wt% for linear polymers, regardless of their molecular weight in the biologically relevant molar masses, was determined solely for linear polymers.
| This journal is © The Royal Society of Chemistry 2025 |