Open Access Article
Amir
Jangizehi
a,
Mostafa
Ahmadi
a,
Sarah
Pschierer
a,
Paola
Nicolella
a,
Hailong
Li
b,
Katrin
Amann-Winkel
b and
Sebastian
Seiffert
*a
aJohannes Gutenberg University Mainz, Department of Chemistry, Duesberwerg 10–14, D-55128 Mainz, Germany. E-mail: Sebastian.seiffert@uni-mainz.de
bMax Planck Institute for Polymer Research, D-55128 Mainz, Germany
First published on 30th August 2022
Byssus threads of mussels have high resistance against abrasion in wave-swept habitats because of their outer cuticle, which is rich in amino acid dopa complexes with Fe3+ ions. This stems from the transient nature of metal–ligand complexes that creates extra relaxation mechanisms. Inspired by this concept, in this work, supramolecular hydrogels based on poly(acrylic acid) functionalized with nitrocatechol groups are synthesized. Polymer chains are physically crosslinked via nitrocatechol–Fe3+ complexes. The hydrogels have different polymer volume fractions as well as different nitrocatechol
:
Fe3+ molar ratios. The strength of the supramolecular crosslinks strongly depends on the pH of the medium. The dynamics of these hydrogels are studied by stress relaxation experiments followed by calculation of the relaxation time spectrum. Generally, samples have three relaxation modes, including dissociation of distinct metal–ligand complexes, reptation of sticky polymer chains, and disengagement of network segments from supramolecular aggregates and clusters. Such clusters hinder the terminal relaxation and potentially increase the stability of supramolecular hydrogels.
One of the key points that should be taken into account for the synthesis of supramolecular hydrogels is the stability of transient association in polar media like water. Generally, the transient interactions are weakening in water, for example, a single hydrogen bond can easily dissociate in water.1,7 To increase the stability of hydrogen bonds in water, several strategies like utilizing associative groups with multiple hydrogen bindings, hydrophobic shielding, and/or combining with other types of physical interactions like π–π conjugations have been studied.11–15 Besides such stabilization of supramolecular associations, the polymer volume fraction is a key factor for preparing a stable supramolecular hydrogel. This factor is specifically critical if the hydrogel is immersed in an excess amount of water after formation of a stable hydrogel at a defined concentration.13,16 In this case, the swelling capacity of the hydrogel and the stability of the physical crosslinks at the equilibrium swelling condition are key parameters. This might be one of the reasons that most of the studied supramolecular hydrogels contain less than 98% water (in equilibrium swelling or out of equilibrium swelling).1 However, in a few studies, supramolecular hydrogels with even more water content, like up to 99.7%, have been successfully prepared and investigated.17
One of the promising types of physical interactions that are utilized to prepare supramolecular hydrogels is metal–ligand complexation. This physical bonding covers a very broad range of binding energies (0–400 kJ mol−1), depending on the metal ion and the ligand, making them promising for the design of tough and stiff supramolecular hydrogels.18 In addition, via oxidation or reduction of the metal ion center, it is possible to trigger or avoid the self-assembly and the sol–gel transition.19,20 One of the well-known examples of metal–ligand-based supramolecular materials in nature is the byssus threads of mussels, in which histidine-rich domains coordinate to transition metal ions like zinc and copper, giving self-healing properties to this stiff material. In addition, the threads are protected by an outer cuticle, which is rich in amino acid dopa complexes with Fe3+ ions.21 Inspired by these concepts, Messersmith and coworkers prepared a series of hydrogels by metal–ligand complexation of histidine-functionalized tetra-arm poly(ethylene glycol), tetra-arm PEG, with transition metals like zinc, copper, cobalt, and nickel. The results revealed that the sol–gel transition (gel formation), and the relaxation time of the hydrogels can be controlled by the type of the metal ion and the pH of the gel formation medium.22 It is also shown that by rational use of the two metal ions in formation of a single network, the hierarchical self-assembly of the supramolecular motifs can be engineered, which has a significant impact on the mechanics and dynamics of the obtained hydrogels.23 The complex of catechol and Fe3+ shows an extremely large equilibrium constant (1040 M−1), making the required force for rapture of a single bond comparable with the one of covalent bonds. However, in contrast to covalent bonds, the dissociated catechol–Fe3+ bond can be reformed due to its achievable reformation rate.21 The stoichiometry of catechol–Fe3+ complexation strongly depends on the pH of the bond formation medium. By increasing pH, it changes from mono-, to bis-, and to tris-type assembly.24 In a case of tris-complexation, the elastic modulus of hydrogels with a bulk structure of catechol-functionalized tetra-arm PEG is comparable with a model covalent network prepared with the same precursor and at similar concentration.24 A similar polymer precursor has been also coordinated with vanadium and aluminum salts. The results revealed that variation of the bonding dynamics is a powerful tool to tune the viscoelastic properties over several orders of magnitude.25 In addition, by using derivatives of catechol like nitrocatechol (ND) or 3-hydroxy 4-pyridinone, it is possible to promote tris complexation to form stable and robust gels at lower pH, compared to that required for the catechol group, without significant reduction in binding strength. Investigation of the rheological properties of the corresponding hydrogels with an identical tetra-arm PEG scaffold demonstrated almost similar plateau moduli, but significantly different relaxation times ranging from 0.09 s (for plain catechol) to 125 s (for 3-hydroxy 4-pyridinone).26 Besides the effect of the ligands, Ma and Hou showed that by changing the microstructure of the hydrogels network to a side-chain supramolecule polymer, it is possible to modulate the dynamics and mechanics of the obtained hydrogels. To reach this target, the authors prepared catechol-functionalized (meth)acrylamide monomers and made precoordinated crosslinkers by mixing them with Fe3+ solution. Hydrogels were prepared by employing an appropriate photo-initiator. With this method, it was possible to prepare a hydrogel with high extensibility and fast self-healing properties.27 Nevertheless, the origin of this significant improvement in the hydrogel properties upon changing the microstructure of the polymeric network platform has not been discussed.
In this work, we investigate hydrogels with side-chain supramolecular polymeric structure formed by integrating nitrocatechol (ND)–Fe3+ complexes along sodium acrylate and hydroxyethyl acrylate random copolymers. The target of using sodium acrylate is to increase the theoretical potential of water adsorption. The metal–ligand complexation and the mechanical properties are probed by UV-vis spectroscopy and rheology. The analysis of the rheological data is done with specific attention to potential clustering of the associative groups. The results confirm aggregation and clustering of the metal–ligand complexes on top of entanglement of the sticky polymer chains. Such supramolecular aggregations influence the terminal relaxation of hydrogels and with that potentially their stability.
COH), 7.46 (s, 1H, C
CNO2) ppm.
3), 1.49 (d, 2H, C
2CH, polymer backbone), 2.21 (s, 1H, CH2C
, polymer backbone), 3.77 (s, 0.1 H, C
2CH2OH), 4.17 (s, 0.1 H, CH2C
2OH) ppm.
3), 1.52 (d, 2H, C
2CH, polymer backbone), 2.23 (s, 1H, CH2C
, polymer backbone). 2.84 (s, 0.10 H, NCOC
2), 3.77 (s, 0.04H, C
2CH2OH), 4.32 (s, 0.10H, CH2C
2OH; C
2CH2OCO), 4.52 (s, 0.07H, CH2C
2OCO) ppm.
3), 1.61 (d, 2H, C
2CH, polymer backbone), 2.20 (s, 1H, CH2C
, polymer backbone), 2.81 (s, 0.10 H, NCOC
2), 3.69 (s, 0.04H, C
2CHOH), 4.26 (s, 0.10H, CH2C
2OH; C
2CH2OCO), 4.52 (s, 0.08H, CH2C
2OCO) ppm.
3), 1.82 (d, 2H, C
2CH, polymer backbone), 2.40 (s, 1H, CH2C
, polymer backbone), 4.39 (s, 0.10H, CH2C
2OH; C
2CH2OCO), 6.86 (s, 0.02H, CC
COH), 7.67 (s, 0.02H, C
CNO2).
:
1. To prepare the probed solutions, a determined volume of Fe(III) sulfate solution in water with a concentration of 0.19 mol/L is added to the solutions of poly(AAc-ran-NC) or nitrodopamine hydrogensulfate in water with a concentration of 10−4 mol L−1. The probed solutions are stirred for 20 min. The pH is then adjusted by using hydrochloric acid solution (0.25 mol L−1) or sodium hydroxide solution (0.25 mol L−1).
:
Fe3+ ions set to 3
:
1, 2
:
1, or 4
:
1 is added to the polymer solution. After stirring for 30 min at room temperature, NaOH solution (10 wt%) is added to the mixture with a ratio of 1 μL solution per 10 mg of polymer solution. After 24 h of shaking at room temperature, the obtained gels are loaded onto the rheometer. For each sample, step strain measurement at T = 10 °C, 20 °C, 30 °C, and 40 °C followed by a frequency sweep measurement at 20 °C and 30 °C are done. In detail, each sample is equilibrated first at γ = 0% and T = 10 °C for 10 min. Then, the shear deformation is increased to γ = 10% for 34 min, during which the change of the stress is investigated. This protocol is repeated at 20 °C, 30 °C, and 40 °C. The sample is equilibrated at γ = 1%, ω = 0.1 rad s−1 for 10 min. At this shear rate and temperature, the frequency sweep measurement is done in the frequency range of 100–0.01 rad s−1. This protocol is repeated at 30 °C, 20 °C, and 10 °C.
000 g mol−1 (see the GPC spectrum in Fig. S6 in the ESI†). The comonomer content is 5, 10, and 15.5 mol%, as determined by 1H NMR. The polydispersity of these copolymers increases upon increase of the comonomer content due to the general weakness of classical ATRP in the polymerization of polar monomers. The copolymers are reacted with disuccinimidyl carbonate to replace the hydroxy groups with N-hydroxy succinimidyl groups, thereby providing active sites for the subsequent click reaction with amine groups. The efficiency of this reaction is between 40–50%. In the next step, tert-butyl acrylate groups are hydrolyzed into acrylic acid groups by using trifluoroacetic acid dissolved in dichloromethane. Such a conversion depends on the comonomer content and gets lower with increasing the mol-percentage of hydroxyethyl acrylate. The non-hydrolyzed tert-butyl acrylate units limit the solubility of the copolymers in polar solvents like DMSO and water, which are the solvents in the following synthesis steps. Due to this limitation, only the copolymer with 5 mol% of comonomer could be used to prepare a hydrogel suitable for further investigations. This sample wherein 2.5 mol% of hydroxyl groups were replaced with succinimidyl groups is reacted with nitrodopamine hydrogensulfate in phosphate buffer medium to attached 2.5 mol% nitrocatechol groups to copolymer chains via urethane linkages. Considering the molar mass of the polymer determined by gel permeation chromatography and the integration peaks of 1H NMR, the average number of nitro catechol, NC, groups per chain is 6. This polymer is used to prepare supramolecular hydrogels at three different concentrations of 10 wt%, 15 wt%, and 20 wt% with a molar ratio of NC
:
Fe3+ = 3
:
1 as described in Experiments. In addition, at the highest concentration, two more hydrogels with different molar ratios of NC
:
Fe3+ = 2
:
1 or 4
:
1 are also prepared to investigate the effect of the ligands to the metal ions stoichiometry on hydrogel properties. Samples are designated as pAAX_NCY, where X denotes the polymer weight fraction and Y represents the molar ratio of NC to Fe3+ ions. For example, sample pAA10_NC3 is prepared by the polymer solution with a concentration of 10 wt% and a molar ratio of NC to Fe3+ of 3. This library of five as prepared supramolecular hydrogels, in which the concentration of precursor polymer and/or the molar ratio of the associative groups are varied are considered for further characterizations and analysis.
![]() | ||
| Fig. 1 UV-vis spectra of nitrodopamine hydrogen sulfate and poly(AAc-ran-NC) (A) without and (B) with presence of Fe3+ ions. The insets represent the results of polymeric samples. | ||
Considering the nature of complexation between NC and Fe3+ ions, shifting from the fully-protonated over the mixture of fully- and mono-protonated to fully-deprotonated state in NC results in shifting from mono-complex over bis-complex to a mixture of bis- and tris-complexes, and eventually to almost pure tris-complex. Such a transformation can be recognized by tracking the variation of the maximum wavenumber in the UV-vis spectrum of the mixture of Fe2(SO4)3 with either nitrodopamine hydrogen sulfate or poly(AAc-ran-NC) solutions (Fig. 1B). Similar to that observed in the UV-vis spectra of plain solutions without iron ions, by increasing the pH, the maximum shifts to a higher wavelength, where such a shifting requires higher pH in the case of the polymeric solution compared to the small molecule solution. This correlation can be considered as an evidence that the protonation state of hydroxy substituents on the aromatic ring of NC group has a direct impact on the complexation type of NC and Fe3+ ions. According to the UV-vis data, nitrodopamine and Fe3+ ions form mono-, bis-, mixture of bis- and tris-, and tris-complexes in the pH of 2.5, 5.8, 6.5–11.4, and 12.5, respectively. In the case of poly(AAc-ran-NC), the pH range changes to 5.7–6.5, 10.3–11.4, and 12.5, respectively, without observing a mixture of bis- and tris-complexes.
![]() | (1) |
![]() | (2) |
i, wi, and PDIi represent the average relaxation time, its corresponding weight, and polydispersity index, respectively, for the relaxation mode i; all should be considered as fitting parameters. The number of the relaxation modes is estimated following the analysis of the dynamic moduli. The G′′ curve for all samples reveals a weak bump at high frequencies and a maximum at low frequencies. Directly after this maximum, samples show no terminal relaxation. Instead, dynamic moduli drop in parallel and as revealed by the stress relaxation data, there is even a tendency to form a plateau. Such rheological properties are commonly observed in supramolecular materials, in which on top of the distinct transient associations, aggregation of them into separated domains, known as clusters, occurs. The phase separation along with aggregation of transient associations hinder the terminal relaxation. Nevertheless, the terminal relaxation mechanism can still occur at very long time, which is not experimentally accessible. Therefore, we hypothesize that at least three relaxation modes are involved in the dynamics of such samples.31 By including the third relaxation mechanism, the results are generally better compared to those obtained with considering only two relaxation modes. Comparison of the calculated results with the experimental data and the obtained relaxation time spectrum for sample pAA10_NC3 are shown in Fig. 2B and C, respectively. The relaxation time spectrum at 30 °C involves three modes, but the fastest mode at ∼1.5 s is overlapped with the high-intensity mode at ∼105 s. To provide a quantitative view of the fitting procedure, all fit parameters are provided in Table S1 in the ESI.† Moreover, for other samples, the stress-relaxation graphs are shown in Fig. S7 in the ESI.†
The weight of each mode is a criterion showing how each mode affects the overall relaxation process. If wi is too small, for example less than 1%, relaxation mode i is neglected. For samples with NC
:
Fe3+ = 3
:
1, the times corresponding to the relaxation modes are 0.1–0.95 s for the fastest relaxation, 130–260 s for the intermediate one, and 9.8 × 104–1.0 × 105 s for the slowest relaxation mode, where the major relaxation mode is the intermediate one with the weight fraction of 85–90%.
In hydrogels with tetra-arm PEG bulk structure, crosslinked by the binary complexation of catechol/nitrocatechol with Fe3+ ions, the time scale of the relaxation that is caused by the dissociation of supramolecular crosslinks is between ∼0.07 s to ∼6 s.24–26 With this evidence, the fastest relaxation mode can be attributed to the dissociation of single, distinct NC–Fe3+ complexes.
To analyze the other two relaxation modes, it is necessary to estimate first if the precursor chains of the networks are entangled.9 For this target, the volume fraction threshold for the entanglement (ϕe) is estimated by32
![]() | (3) |
000 g mol−1) to the entanglement molar mass of poly(acrylic acid) (6900 g mol−1). Since hydrogels are prepared in basic pH, we consider υ = 1 leading to ϕe = 0.052. Therefore, the volume fraction of all hydrogels are above the threshold of entanglement, thereby, polymer chains could relax through disentanglement mechanism. For precursor polymer chains, the disentanglement time, calculated from the reptation theory, is in the scale of 10−6 s. Due to the presence of the transient associations in the side-chain position, however, the relaxation time corresponding to this mechanism is estimated by the sticky reptation theory34 as![]() | (4) |
The third relaxation mode of the hydrogels is in the range of 105 s, which is out of the accessible time scale of our experiments. To investigate this relaxation mode in more detail, dynamic moduli of hydrogels at 20 °C and 30 °C are estimated from the relaxation spectrum by using eqn (5) and (6)
![]() | (5) |
![]() | (6) |
Considering the effect of the polymer concentration, no clear effect has been observed on the time scale of the fastest and longest relaxation modes. The former is expected as the lifetime of the distinct NC–Fe3+ complex does not depend on the polymer concentration. The latter might be related to the super large time scale, where the minor change in the values is not detectable by our fitting approach. In contrast, increasing the concentration increases the intermediate relaxation time as shown in Fig. 4A. This observation is related to the effect of polymer concentration on the sticky reptation time as suggested by eqn (4) (τrep ∝ ϕ0.55).
A similar analysis is done on samples with 20 wt% polymer concentration, in which the molar ratio of NC and Fe3+ ions is varied. The calculated frequency sweep graphs based on fitting stress relaxation data is demonstrated in Fig. 4B. The weight of the third relaxation is less than 1% for sample pAA20_NC2, which means that formation of stable clusters is negligible. The reason could be related to the presence of extra metal ions which push the complexation equilibrium towards formation of mono- and bis-complexes. This confirms that the stability of transient associations is one important factor that promote formation of clusters. This lower number of supramolecular crosslinking can explain the considerably lower plateau modulus of this sample compared to the sample pAA20_NC3. The lack of long-lasting clusters and the lower crosslinking density in this sample results in a more prominent crossover of G′ and G′′ at 30 °C compared to sample pAA20_NC3. The data at 30 °C also shows that this sample has a tendency for viscous flow at long time scales. The changing of stoichiometric ratio from 3
:
1 to 4
:
1 also influences the dynamics and mechanical properties of the hydrogel, however, this effect is considerably lower compared to what was observed for sample pAA20_NC2. The weight of the longest relaxation mode in sample pAA20_NC4 is comparable with that of sample pAA20_NC3. This is in agreement with no apparent viscous flow for sample pAA20_NC4 similar to sample pAA20_NC3. However, the plateau modulus of this sample is still lower than that of pAA20_NC3, which is related to the lower crosslinking density due to the lower amount of Fe3+ ions than what is needed to form tris-complexes.
In summary, we hypothesize that all studied hydrogels (except sample pAA20_NC2) have three relaxation mechanisms, with corresponding time scales that vary six orders of magnitudes from 0.1 s to 9.8 × 104 s. The fastest relaxation mode is attributed to the distinct, single NC–Fe3+ dissociation. The intermediate relaxation mode, with a time scale of 130–260 s and weight fraction of 85–90%, is related to the disentanglement of sticky polymer chains. The slowest relaxation mode is attributed to the disengagement of polymer segments from the aggregates of NC–Fe3+ complexations formed by the collective assembly of distinct transient bonds. The distinct association of NC–Fe3+, entanglement of stick chains, and the aggregation of supramolecular complexes are sketched in Scheme 2. The existence of long-lasting aggregates and clusters in our studied samples features in computational and experimental frequency sweep graphs by shifting the G′ and G′′ crossover to low frequency ranges and preventing the viscous flow of polymer chains in the terminal region.
In addition, this phenomenon can be confirmed by scattering techniques like small angle X-ray scattering (SAXS). The scattering intensity profile of sample pAA20_NC3 is represented in Fig. 5. At 0.0088 < q < 0.02 Å−1, the intensity profile demonstrates a power-law decay with a slope of −4, which could be related to the scattering objects that are too big to be resolved by this technique. In the following, at 0.02 < q < 0.1 Å−1, a shoulder emerges, which indicates the presence of scattering objects with the size of 1–5 nm. The appearance of this shoulder confirms our hypothesis about the presence of non-ordered aggregates of transient complexes in this sample. To have a better estimation of the size of these aggregates, the data is fitted with the modified Porod model as well as the modified Ornstein–Zernike model. The first model fits data well at q < 0.02 Å−1, where the intensity profile demonstrates a power-law decay. The second model fits well the middle q data, where the shoulder emerges. Therefore, the combination of both models can describe the scattering data in the whole covered range of q. The main outcome of the modified Ornstein–Zernike model is the correlation size of aggregates, which is predicted at 16 nm for sample pAA20_NC3. This value is larger than the covered size range, which might be related to the broadness of this shoulder and the absence of plateau at the very low q values.
The aggregation of supramolecular associations into clusters and with that the stability and the relaxation time of the bulk network can be controlled by the pH of the hydrogel formation medium, the polymer concentration and the molar ratio of NC and Fe3+ ions. Regarding the latter parameter, the sample with a molar ratio of NC
:
Fe3+ = 2
:
1, reveals the tendency of viscous flow in the frequencies lower than that of the crossover of the dynamic moduli, which is hypothesized to be related to the lack of stable clusters. This result is confirmed by the absence of any shoulder in the middle q range of the scattering intensity profile of this sample as is represented in Fig. 5.
The influence of supramolecular clustering on the relaxation time of supramolecular hydrogels is an effective approach to form stable hydrogels. For example, the rational use of the collective assembly/stacking of the associative motifs for stabilizing single associated dimers has been extensively investigated in hydrogen-bonded hydrogels.11,12,14 This motivates us to investigate the stability of studied hydrogels in presence of an excess amount of water. While the studied hydrogels have no possibility for terminal relaxation within the studied time scales, the as prepared samples are not stable if they are immersed in an excess amount of water. This means that at some point during the water adsorption process, the gel–sol transition occurs before hydrogels could reach their swelling equilibrium. This instability limits the potential application of such materials for diverse applications, in which hydrogels should be stable in the desired environment (for example water), where the content of the surrounding medium is significantly greater than the amount of the water in as prepared hydrogels. One reason for this instability is the chemical nature of the bulk network of these hydrogels. The acrylic acid and its sodium salt are well known for the preparation of superabsorbers, which are able to retain a huge amount of water within their networks compared to the dry weight of the materials. One approach to prepare more stable hydrogels is to change their chemistry into a structure with less polarity and/or less osmotic pressure. In this sense, the method of hydrogel preparation should be modified, considering the limitation of solubility of less polar polymer chains in the aqueous medium, which is explained in Experiment. In addition, more stable hydrogels can be prepared by increasing the level of the aggregation of supramolecular motifs. This can be achieved, for example, by the increase of the molar mass of the polymer chains.37,38 Investigation of these parameters is the topic of our further studies.
:
1 on a poly(AAc-ran-NC) network platform depends on the pH of the hydrogel preparation medium. By increasing the pH from 4 to 12, NC–Fe3+ ligand–metal association gets more stable by shifts from mono-complex over bis-complex to a mixture of bis- and tris-complexes, and eventually to almost pure tris-complex as visualized in Scheme 2. The best concentration range for the preparation of hydrogels is between 10 and 20 wt%. At lower polymer concentrations, the sol–gel transition does not occur at room temperature, whereas at higher concentrations, the formed hydrogels are very inhomogeneous because of the impossibility of mixing components during hydrogel formation due to the high viscosity of the polymer solutions. All samples with NC
:
Fe3+ = 3
:
1 have three relaxation modes. The fastest one is related to the dissociation of distinct NC–Fe3+ complexes. The intermediate relaxation mode, which is the major one, determined at time scales of 130–260 s, is related to the disentanglement of sticky polymer chains. The third relaxation mode, with extremely long relaxation time, is attributed to the long-lasting clusters. While the weight fraction of such clusters is less than 5%, the viscous flow with the fingerprint slopes of 2 and 1 for G′ and G′′, in the terminal region, is not observed in the log–log frequency sweep plots of these samples. The extent of clustering can be controlled by the molar ratio of NC and Fe3+ ions. For example, by changing the molar ratio of NC
:
Fe3+ to 2
:
1, the clustering of transient complexations is low enough such that the low-frequency G′–G′′ crossover and the terminal relaxation are experimentally accessible.
Footnote |
| † Electronic supplementary information (ESI) available. See DOI: https://doi.org/10.1039/d2sm00666a |
| This journal is © The Royal Society of Chemistry 2022 |