Open Access Article
Chi-Xin Duab and
Zhu Huang
*ab
aDepartment of Ophthalmology, The First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou, China. E-mail: flycatty@zju.edu.cn
bDepartment of Ophthalmology, The Fourth Affiliated Hospital, College of Medicine, Zhejiang University, Yiwu, China
First published on 11th November 2019
Amino acids in human tears play certain physiological roles and their determination is challenging due to complicated chemical properties. This study described a fast and sensitive method for the simultaneous determination of 15 amino acids (AAs) in tears by hydrophilic interaction liquid chromatography and quadrupole orbitrap mass spectrometry (HILIC-Q-Orbitrap-MS). Amino acids in tears were extracted by methanol, and then cleaned up with a solid phase extraction (SPE) cartridge. Chromatographic separation was performed on a 1.7 μm BEH Amide column within 8 min. Tear samples spiked with free AAs were tested in terms of linearity, sensitivity, repeatability, and recovery. Two stable isotope-labeled amino acids were used as internal standards to improve the method performance. Recoveries for all analytes ranged from 89 to 107%. Intra-day and inter-day precision, expressed as relative standard deviations, were all below 10%, and the method detection limits ranged from 0.02 μmol L−1 to 0.11 μmol L−1. The developed method with high throughput and high analyte specificity shows good promise for consistent analysis of free amino acids in tears.
Amino acids have diverse physical functions. Conventionally, they have long been considered a source of protein synthesis, and play a key role in the regulation of the body metabolism of living organisms. It is now widely accepted that changes in amino acid have profound effects on many aspects of cellular functions, such as gene expression, cell signaling, and the transport of amino acids.5–7 Previous reports have pointed out that some amino acids can reduce inflammation by inhibiting NF-κB activation, IL-6 production and expression of the leukocyte adhesion molecule CD62E.8,9 Accordingly, exploring amino acids at a trace level in clinical samples prompted the need for a reliable, sensitive and convenient test method.
Previous reports showed that high performance LC (HPLC) with pre- or post-column derivatization and ultraviolet (UV) or fluorescence (FL) detection was the widespread analytical methods for amino acids.10–12 But it still remains a challenge to quantify amino acids at trace level in complex biological matrices. More recently, liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been adopted for amino acid analysis in physiological samples due to its excellent selectivity and sensitivity.13–18 However, co-eluting endogenous compounds in the matrix interferes with ionization efficiency and reproducibility of the ionization source. To enhance the detection sensitivity and chromatographic retention, derivatization reagents such as o-phthaldialdehyde and 9-fluorenylmethyl chloroformate were applied.15 However, the methods with chemical derivatization may suffer from laborious sample preparations as well as long testing time.19,20 With the development of mass spectrometry (MS) technology, such as orbitrap MS and time of flight (ToF) MS, high resolution MS has become an acceptable method for the direct analysis of amino acids (AAs).21,22
Moreover, successful chromatographic separation of amino acids is helpful to the quantification. Usually, reverse-phase high-performance liquid chromatography (HPLC) is used for separation of organic chemicals. However amino acids almost have no retention on normal C18 in analysis of physiological samples due to their high polar and zwitterionic property.13 Hydrophilic interaction liquid chromatography (HILIC) is suitable for separation of strongly or moderately polar samples. With highly organic mixed mobile phases, it improves the retention of polar compounds and offers a potential analysis method for amino acids in clinic samples without derivatization or ion-pairing agents. Indeed, usage of HILIC with MS detection to amino acids in biological matrix, as well as clinic samples such as urine, plasma and serum have been successfully applied.17,18 However, to our knowledge, few reports refer the analysis of amino acids in human tears through HILIC coupled with high resolution mass spectrometry.4
In this study, we developed a liquid chromatography high resolution mass spectrometry method for the simultaneous determination of 15 amino acids (AAs) in human tears. AAs in tears were extracted by methanol and then treated with solid phase extraction (SPE) for clean-up. Separation of AAs was achieved using a HILIC column and detected by Q-Orbitrap mass spectrometry without derivatization. The mode of PRM in Orbitrap instrument was adopted for the quantification of AAs coupled with stable isotope-labeled internal standards.
LC-MS grade acetonitrile (ACN) and ammonium formate, ammonium acetate, ammonia, acetic acid and FA from Merck (Darmstadt, Germany) were used to prepare the chromatographic mobile phases. Deionized water from a Millipore Milli-Q water purification system was used to prepare all aqueous solutions. 36.5% (v/v) hydrochloric acid employed for sample preparation was purchased from Merck (Darmstadt, Germany).
000 rpm. The supernatants were then dried by N2 flow at 40 °C and re-dissolved in 1 mL water containing 0.2% FA for later clean up.
The extraction was further handled by three different solid phase extraction (SPE) cartridges of HLB, MCX, and WCX (1 cm3, 30 mg, Waters Milford, MA, USA). The experimental procedure was based on the suggestions of the supplier and reported methods.23 (i) Equilibration: the cartridges were conditioned with 1 mL of methanol followed by 1 mL of water for HLB. For MCX, and WCX, the cartridge was conditioned with 1 mL of methanol followed by 1 mL of acidified water (1% FA). (ii) Loading: acidified samples (0.2% FA) were loaded for HLB, MCX and WCX. (iii) Washing: 1 mL methanol containing 10% water and 0.1% FA was used for all cartridges and repeated at twice. (iv) Elution: 1 mL methanol containing 6% NH4OH was used for elution and repeated at twice. Subsequently, eluted solutions were dried by N2 flow at 40 °C and re-dissolved in 1 mL water containing 0.2% FA for further instrumental analysis. The performance of SPEs treatment was evaluated by samples spiked with 15 amino acids standard solution at level of 300 μmol L−1. Spiking recovery was calculated as: (measure value − matrix value)/spiking value × 100. The whole work flow of AAs analysis can be seen in Fig. 1.
Chromatographic separation was performed on an ACQUITY UPLC BEH Amide column (1.7 μm, 2.1 × 150 mm) (Waters Corporation, MA, USA) at 40 °C. Mobile phase A (50/50 acetonitrile/H2O) and B (95/5/5 acetonitrile/methanol/H2O) both contained 8 mM ammonium formate and 0.2% formic acid. A gradient elution that started at 90% B for 1 min and decreased linearly to 30%, 1–3 min; 30–60% B, 3–4 min; 60–95% B, 4.0–5.5 min; 95% B, 5.5–6.5 min; 95–90% B, 6.5–8 min. The flow rate was 0.4 mL min−1. The sample injection volume was 5 μL.
Q-Orbitrap MS with HESI-II electrospray source was operated in positive mode. The following ionization parameters were applied: electrospray voltage 3.8 kV for positive mode, capillary temperature 340 °C, vaporizer temperature 250 °C, sheath gas (N2) 40 arbitrary units (arb), auxiliary gas (N2) 15 (arb), and S-Lens RF level at 45 (arb). The instrument was calibrated in positive mode every 7 days using the Pierce LTQ Velos ESI positive-ion calibration solutions (Thermo Scientific, San Jose, CA, USA). The MS parameters of PRM were: default charge 1, inclusion on for monitoring only targeted precursor (Table 1), ms2 resolution 17
500, maximum IT 100 ms, AGC target 1.0 × 106, and isolation window 2.0 m/z. Stepped normalized collision energy (NCE) was 20, 38 and 60. The accurate masses for the precursor are shown in Table 1. The spectra and resulting peaks were manually extracted and evaluated using the Xcalibur software (Version 2.1, Thermo Fischer). Precursor and fragment mass error tolerances were set at 4 ppm and 0.2 Da.
| Comment | Formula [M] | Precursor (m/z) | Fragment (m/z) | Retention (min) | Linear range (μmol L−1) | r2 | LODs (μmol L−1) |
|---|---|---|---|---|---|---|---|
| Arginine | C6H14N4O2 | 175.1190 | 70.0659/116.0709 | 3.65 | 0.1–600 | 0.996 | 0.05 |
| Aspartic acid | C4H7NO4 | 134.0448 | 87.1004/74.0244 | 3.47 | 0.1–600 | 0.995 | 0.09 |
| Cysteine | C3H7NO2S | 122.0270 | 95.0498/104.0581 | 2.59 | 0.1–600 | 0.996 | 0.06 |
| Glutamic acid | C5H9NO4 | 148.0604 | 84.0451/74.0067 | 3.14 | 0.5–600 | 0.991 | 0.11 |
| Histidine | C6H9N3O2 | 156.0768 | 110.0716/103.2544 | 4.16 | 0.1–600 | 0.992 | 0.08 |
| Isoleucine | C6H13NO2 | 132.1019 | 86.0971 | 1.08 | 0.1–600 | 0.995 | 0.04 |
| Leucine | C6H13NO2 | 132.1019 | 86.0971 | 1.26 | 0.1–600 | 0.994 | 0.02 |
| Lysine | C6H14N2O2 | 147.1128 | 130.0863 | 3.99 | 0.5–600 | 0.992 | 0.03 |
| Methionine | C5H11O2NS | 150.0583 | 104.0533/133.0319 | 1.12 | 0.1–600 | 0.993 | 0.03 |
| Phenylalanine | C9H11NO2 | 166.0863 | 120.0810/103.0547 | 1.05 | 0.1–600 | 0.995 | 0.02 |
| Proline | C5H9NO2 | 116.0706 | 70.0659 | 1.78 | 0.1–600 | 0.996 | 0.04 |
| Serine | C3H7NO3 | 106.0499 | 60.0453/88.0400 | 3.03 | 0.1–600 | 0.991 | 0.06 |
| Threonine | C4H9NO3 | 120.0655 | 103.0547/74.0608 | 2.80 | 0.1–600 | 0.992 | 0.04 |
| Valine | C5H11NO2 | 118.0863 | 72.0816 | 1.59 | 0.1–600 | 0.995 | 0.03 |
| Valine-d8 | C5H3D8NO2 | 126.1365 | 108.1259 | 1.59 | — | — | — |
| Cysteine-d3 | C3H4D3NO2S | 125.0459 | 107.0353 | 2.59 | — | — | — |
000 FWHM), accurate mass measurement (<2 ppm), excellent full MS scan sensitivity, and complete mass spectral information. The full MS scan data allow for screening of targeted analytes, confirming positive findings, identifying unknowns or metabolites, and retrospective analysis. Currently, the quadrupole Orbitrap can achieve a high resolving setting for 70
000 or 140
000 FWHM, which ensures highly accurate mass measurements and enables confident discrimination of coeluting, isobaric compounds in complex matrices. Moreover, Q-Orbitrap-MS provides product-ion spectra with accurate mass measurement that permit unequivocal confirmation of compounds of interest.24,25 Accordingly, it might be a good choice for the AAs analysis in tears with Q-Orbitrap.
To achieve the highest selectivity and sensitivity, mass spectrometry parameters including ionization mode, capillary voltage, source temperature, sheath gas flow, and collision energy were optimized using AAs standards. The results indicated that most abundant ions (precursor ions) of the AAs were their molecular ions [M + H]+ in positive ion mode. The m/z of precursor ions [M + H]+ and characteristic fragment ions for each AA under positive ion mode are listed in Table 1.
PRM scan mode in Q-Orbitrap mass spectrometry is designed for analyte quantification by the MS/MS response. Unlike the MRM of triple quadrupole mass spectrometry, PRM runs with targeted precursor ions screened by quadrupole and transferred via the C-trap to the HCD cell for fragmentation (product ions). We found that the stepped value of 20, 38 and 60 of normalized collision energy (NCE) can satisfied the sensitivity of the fragment ions for all AAs. Considering the intensity, the first fragment ion was used for quantification in PRM mode. The intensity was calculated by chromatographic peak area. The balanced dynamic range C-trap setting (1 × 106) was selected to combine the high sensitivity of detection with the extended linear range of quantification. This parameter shows the capacity of any ion trap to control the number of ions. Higher value of the C-trap dynamic range can improve the sensitivity of selected ions through more ion accumulation.
![]() | ||
| Fig. 2 Representative chromatograms of 15 amino acids (spiking level of 20 μmol L−1) in HILIC-Q-Orbitrap with PRM mode. | ||
To optimize the chromatographic condition, the organic content and buffer concentration in mobile phase were investigated. Similarly to the report of Gao et al.,23 we found that the increase of buffer concentration made narrow and high peaks of some AAs, such as Asn, Asp, Glu, Lys, Met and His, while it simultaneously decreased MS response (peak height) for other amino acids. The ion suppression or enhancement in mass spectrometry may be produced with the buffer in mobile phase. Moreover, change of buffer concentration between 2 to 10 mM can result in shifting of retention time for some basic or acidic amino acids, such as Arg, Asp, His and Lys. Considering the overall positive effects of higher buffer concentration, especially on Asp and His, we selected a concentration of 8 mM NH4HCO2 (0.2% FA) as the buffer solution in mobile phase.
| Amino acids | Mean recovery (%) (n = 5) | RSD (%) (n = 5) | ||||
|---|---|---|---|---|---|---|
| Oasis HLB | Oasis MCX | Oasis WCX | Oasis HLB | Oasis MCX | Oasis WCX | |
| Arginine | 80 | 89 | 70 | 4.5 | 3.5 | 5.1 |
| Aspartic acid | 82 | 90 | 83 | 3.5 | 2.8 | 4.6 |
| Cysteine | 90 | 98 | 85 | 2.4 | 2.5 | 3.1 |
| Glutamic acid | 71 | 79 | 70 | 4.5 | 3.9 | 3.4 |
| Histidine | 80 | 85 | 78 | 3.7 | 2.8 | 3.1 |
| Isoleucine | 75 | 82 | 73 | 4.6 | 5.7 | 4.1 |
| Leucine | 71 | 80 | 74 | 5.9 | 4.9 | 4.6 |
| Lysine | 85 | 90 | 80 | 7.8 | 4.2 | 5.2 |
| Methionine | 72 | 82 | 71 | 5.7 | 3.7 | 3.9 |
| Phenylalanine | 78 | 82 | 73 | 6.5 | 5.6 | 5.5 |
| Proline | 76 | 80 | 71 | 4.8 | 4.1 | 5.3 |
| Serine | 70 | 86 | 73 | 6.7 | 4.6 | 4.8 |
| Threonine | 76 | 91 | 75 | 5.3 | 3.8 | 3.9 |
| Valine | 88 | 96 | 80 | 2.7 | 1.9 | 2.5 |
Table 3 summarizes the intra- and inter-day precision and accuracy of the method evaluated by spiking samples with different levels. Recoveries of intra- and inter-day tests were 89–107%, and the relative standard deviations (RSDs) were 1.1–5.6%.
| Amino acids | Spiking levels (μmol L−1) | Intra-day (n = 6) | Inter-day (n = 3) | ||
|---|---|---|---|---|---|
| Recovery (%) | RSD (%) | Recovery (%) | RSD (%) | ||
| Arginine | 5 | 93 | 3.1 | 91 | 5.6 |
| 200 | 95 | 2.4 | 96 | 2.8 | |
| Aspartic acid | 5 | 89 | 2.8 | 90 | 4.1 |
| 200 | 96 | 2.1 | 95 | 3.2 | |
| Cysteine | 5 | 95 | 3.5 | 94 | 4.6 |
| 200 | 99 | 2.4 | 102 | 3.5 | |
| Glutamic acid | 10 | 92 | 3.2 | 91 | 4.5 |
| 200 | 97 | 2.9 | 95 | 3.9 | |
| Histidine | 5 | 91 | 2.5 | 93 | 4.2 |
| 200 | 98 | 1.8 | 107 | 2.4 | |
| Isoleucine | 5 | 92 | 2.4 | 90 | 3.4 |
| 200 | 102 | 1.9 | 103 | 2.8 | |
| Leucine | 5 | 95 | 2.7 | 94 | 4.8 |
| 200 | 105 | 1.8 | 104 | 3.2 | |
| Lysine | 10 | 91 | 3.8 | 90 | 4.6 |
| 200 | 97 | 2.0 | 98 | 2.9 | |
| Methionine | 5 | 92 | 3.6 | 92 | 4.5 |
| 200 | 96 | 1.7 | 96 | 3.1 | |
| Phenylalanine | 5 | 96 | 3.2 | 91 | 3.9 |
| 200 | 106 | 1.8 | 99 | 2.6 | |
| Proline | 5 | 91 | 2.6 | 93 | 3.8 |
| 200 | 97 | 1.9 | 102 | 2.9 | |
| Serine | 5 | 92 | 3.4 | 95 | 3.4 |
| 200 | 95 | 2.1 | 98 | 2.1 | |
| Threonine | 5 | 94 | 3.3 | 93 | 4.9 |
| 200 | 98 | 1.5 | 99 | 2.7 | |
| Valine | 5 | 94 | 3.4 | 90 | 3.6 |
| 200 | 101 | 1.1 | 95 | 2.1 | |
| This journal is © The Royal Society of Chemistry 2019 |