Haojia
Hong
a,
Lei
Shi
*a,
Junzhe
Huang
a,
Chang
Peng
*b,
Sheng
Yang
c,
Guang
Shao
d and
Shengzhao
Gong
*a
aSchool of Chemical Engineering and Technology, Guangdong Industry Polytechnic, Guangzhou, Guangdong, 510300, P. R. China. E-mail: 2016103059@gdip.edu.cn; 1996103022@gdip.edu.cn
bCollege of Science, Hunan Agricultural University, Changsha, Hunan 411105, P. R. China. E-mail: pch1026@126.com
cHunan Provincial Key Laboratory of Materials Protection for Electric Power and Transportation, School of Chemistry and Biological Engineering, Changsha University of Science and Technology, Changsha, Hunan 410114, P. R. China
dSchool of Chemistry, Sun Yat-sen University, Guangzhou, Guangdong, 510275, P. R. China
First published on 12th November 2018
The development of imaging-suitable fluorescent probes based on fluorogen scaffolds with near-infrared emission is crucial for monitoring cysteine (Cys) in biological systems. Herein, we synthesized a novel NIR dye based on a “donor–π–acceptor” structure which exhibits good Stokes shifts, satisfactory quantum yields, long wavelength excitation and excellent photostability, and a Cys-responsive NIR probe was constructed by decoration with methacrylate. The designed probe possesses great sensitivity and selectivity for detection of Cys. Moreover, it has been successfully applied in detecting Cys in living cells, indicating its great potential value for biological applications.
Fluorescence sensing is one of the most popular analytical methods for detecting biological thiols.3,9,10 Unlike the probes with fluorescent signals within the ultraviolet or visible-light range, the near-infrared (NIR) fluorescent probes are quite suitable for biological imaging applications because of their great technical advantages, such as less damage to biological samples, deeper tissue penetration, and lower interference from the background.11–13
To date, several NIR fluorescent probes for Cys detection have been reported, but most of them are still based on squaraine,14 cyanine dyes,15 naphthofluorescein,6 or dicyano-methylene-benzopyran.16 These probes cannot be effectively utilized due to some of their disadvantages, such as long response times, small Stokes shifts, low quantum yields, low sensitivity and/or complex synthesis. Therefore, it is desirable and necessary to develop novel NIR fluorescent probes for detection and bioanalysis of Cys.
In this study, we synthesized a novel NIR fluorescent fluorophore which was based on a “donor–π–acceptor” structure and possessed good optical performances, and a new fluorescent probe CMC (Scheme 1) was synthesized for detection of Cys. The probe could selectively react with Cys over other biological analytes, and the concentration of Cys could be quantitatively determined by UV-vis absorption or fluorescent signals. More importantly, we have successfully applied this probe in detecting Cys in living cells.
:
1, v/v) to yield compound 3 as dark green solids (1.03 g, 49%). 1H NMR (400 MHz, CDCl3) δ 10.53 (s, 1H), 7.08 (d, J = 8.8 Hz, 1H), 6.93 (d, J = 2.4 Hz, 1H), 6.83 (dd, J = 8.4 Hz & 2.4 Hz, 1H), 6.62 (s, J = 3.2 Hz, 1H), 5.47 (t, 1H), 3.93–3.86 (m, 1H), 3.69–3.64 (m, 1H), 2.82–2.89 (m, 2H), 2.81–2.71 (m, 4H), 1.93–1.86 (m, 2H), 1.61–1.76 (m, 2H). 13C NMR (100 MHz, d6-DMSO) δ 182.9, 163.0, 157.5, 151.8, 137.1, 127.7, 122.3, 115.7, 115.6, 113.3, 103.7, 95.8, 61.5, 29.5, 24.5, 23.6, 23.3, 18.3. ESI-HRMS m/z: [compound 3 + H]+ calcd for C18H18O4 299.13, found 299.1277.
:
1), and the mixture was refluxed for 12 h. Then, trifluoroacetic acid (0.3 mL) was added and the resulting solution was stirred for another 30 min at room temperature. After this, the mixture was concentrated in vacuo and the residue was purified by silica gel column chromatography (CH2Cl2/EtOAc, 10
:
1, v/v) to yield compound 4 as dark purple solids (209 mg, 66%). 1H NMR (400 MHz, d6-DMSO) δ 10.53 (s, 1H), 7.80 (s, 1H), 7.34 (d, J = 8.4 Hz, 1H), 7.23 (s, 1H), 6.79 (s, 1H), 6.75 (dd, J = 8.4 Hz & 1.6 Hz, 1H), 2.91–2.98 (m, 2H), 2.82–2.89 (m, 2H). 13C NMR (100 MHz, d6-DMSO) δ 164.8, 160.2, 153.0, 146.3, 134.0, 128.7, 127.6, 117.2, 116.1, 114.3, 113.8, 113.2, 102.7, 28.9, 24.7. ESI-HRMS m/z: [compound 4 + H]+ calcd for C16H10N2O2 263.08, found 263.0814.
:
1) at an indicated pH value. Then various analytes were added separately and incubated for 30 min, and the UV-vis absorption and fluorescence spectra of these solutions were recorded in a quartz cuvette of 1 cm optical path length. For fluorescence measurements, the excitation wavelength was set at 614 nm with a slit width of 0.5 × 2.5 nm.
| Detection limit = 3σ/k | (1) |
Before the fluorescence imaging experiments, HeLa cells were seeded on 14 mm glass coverslips and allowed to adhere for 24 h. Then, 10 μmol L−1 probe CMC was added to the medium of HeLa cells, and the cells were incubated for 30 min at 37 °C. After washing treatment of the cells with PBS buffer (3 times), fluorescence imaging was carried out. The fluorescence signal was collected at 645–690 nm with a semiconductor laser at 635 nm as the excitation light source.
In this study, the fluorophore of the probe (compound 4) was based on the “donor–π–acceptor” type fluorophore which included a malononitrile moiety as the electron-withdrawing group and a phenolic hydroxyl group as the electron-donating group. Compound 4 displayed good NIR optical performances, such as long wavelength excitation, near infrared emission, good Stokes shift (Δλ = 39 nm), satisfactory fluorescence quantum yield (Φ = 0.19 in a mixture of PBS/DMF) and excellent photostability (Fig. S13, S14 and Table S1, ESI†). Then a methacrylate moiety, as an efficient electron acceptor and a selective reaction site for Cys,22 was introduced to the structure of the fluorophore to obtain probe CMC. As a result, the fluorescence intensity of the fluorophore was severely weakened due to the photoinduced electron transfer (PET) effect. After the addition of Cys, its fluorescence would recover soon by the removal of the acrylate group through selective chemical reactions.
:
1) at room temperature. As shown in Fig. 1 and 2, the probe CMC emitted weak fluorescence in the absence of Cys. Soon after the addition of Cys, the probe's fluorescence band centred at 655 nm was gradually increased, and its UV-vis absorption band was shifted hugely from 480 nm to 614 nm with an apparent change of colour being visualized by the naked eye. Meanwhile, both the ratio of absorbance at 614 nm and 470 nm (A614nm/A470nm) and the fluorescence intensity at 655 nm (I655nm) were linearly dependent on the increased concentration of Cys (Fig. 3). There was good linearity obtained in the range of 0–80 μmol L−1 for Cys with a detection limit of 1.06 μmol L−1. In addition, the absolute fluorescence quantum yield (Φ) values were determined by using an integral sphere according to a previous report,23 and an obvious enhancement of the quantum yield was observed (Φ = 0.033 to 0.192, tested in the mixture of PBS buffer/DMF). These optical testing results manifested that the probe CMC could detect the Cys precisely and sensitively under physiological conditions.
The pH effects on the fluorescence response for probe CMC to Cys were also investigated to evaluate the working pH ranges. As shown in Fig. S15 (ESI†), the probe displays significant responses under neutral or weak alkaline conditions, indicating that the probe CMC would work well in the physiological pH region.
As shown in Fig. 5, after 10 min of adding various amounts of Cys in D2O, the characteristic chemical shifts of alkenyl hydrogen from 5.8 to 6.4 ppm disappeared, indicating the addition reaction proceeding between Cys and the alkene moiety of the probe CMC. And the chemical shifts of aromatic hydrogens moved to high fields and matched the chemical shifts of aromatic hydrogens in compound 4 very well. Meanwhile, the TLC plate also showed the chemical transformation from probe CMC to compound 4 (Fig. S19, ESI†). Moreover, the reaction mixture of Cys and probe was investigated by ESI-MS analysis. As shown in Fig. S20 (ESI†), the peaks at m/z 189.9, 189.9 and 280.8 indicated the formation of intermediate thioether product 5, cyclization product 6 and compound 4. All of these results clarified that the transformation from probe CMC to compound 4 was based on the strategy of the Michael addition and cyclization reaction, and this assumed mechanism shown in Scheme 2 showed a good agreement with a previous report.22
![]() | ||
| Fig. 5 The comparisons of the 1H NMR spectra of probe CMC (d6-DMSO), compound 4 (d6-DMSO) and the reaction mixtures of probe (d6-DMSO) and Cys (D2O). | ||
Afterwards, fluorescence imaging with probe CMC in living cells was carried out. As shown in Fig. 6A, slight fluorescence could be observed when HeLa cells were incubated with probe CMC for 30 min, indicating that the probe CMC was capable of penetrating into cells and detecting endogenous Cys by emitting NIR fluorescence. To validate the probe's specificity to cellular thiols, two control experiments were conducted. First, living cells were pretreated with a well-known thiol-blocking agent N-ethylmaleimide (NEM) for 60 min to deplete intracellular thiol species, and then incubated with the probe. As expected, no fluorescence was observed (Fig. 6B). By contrast, the cells were treated with NEM and Cys in turn, and then incubated with the probe. In this case, a marked time-dependent fluorescence enhancement was found (Fig. 6C). All of these imaging results clearly showed that the probe CMC was not responsive to intracellular compounds except Cys and this probe had great potential for biological applications.
Footnote |
| † Electronic supplementary information (ESI) available: Characterization of chemical sensors and all emission and absorption data. See DOI: 10.1039/c8nj04006k |
| This journal is © The Royal Society of Chemistry and the Centre National de la Recherche Scientifique 2019 |