Cemil
Aydoğan
*a and
Ziad
El Rassi
b
aDepartment of Food Engineering, Bingöl University, 12000 Bingöl, Turkey. E-mail: caydogan@bingol.edu.tr; Tel: +90 426 216 00 36-19 58
bDepartment of Chemistry, Oklahoma State University, Stillwater, OK, USA
First published on 15th November 2018
A monolith based on MWCNTs incorporated into HPMACl was prepared for use as a stationary phase in nano-liquid chromatography. The performance of the monolith was tested at 800 nL min−1, in the separation of several compounds of environmental and pharmaceutical interest, namely antibiotics and pesticides. Good resolution was observed on the MWCNT incorporated column. Excellent separation performance was obtained in most cases. The high chromatographic separation capability and great stability observed in nano LC-UV encouraged the analyses to be carried out via HR Orbitrap MS. The antibiotics and pesticides were then injected into an integrated nano LC-HR Orbitrap MS system and they were identified by their retention time and accurate mass which were measured with product ions in full MS-all-ion fragmentation mode. High sensitivity (at the ppb level) and reproducibility were obtained. The applicability of the method with the monolith was demonstrated using milk and honey samples with the LODs ranging from 0.1 to 20 μg kg−1.
In recent years, the use of nanoparticles (NPs) has been the newest approach to the preparation of monolithic columns. MWCNTs (multiwalled carbon nanotubes) are nanomaterials with sizes of 1–100 nm in more dimensions and show unique properties for many types of applications including medical and electronic.12 These NPs have a large surface area/volume ratio, and mechanical and biological qualities. Recently, the use of MWCNTs has also been adopted in the field of monolithic stationary phases, and MWCNT based monoliths have been prepared and used in reversed-phase chromatography (RPC).13–15 In the preparation of these kinds of monoliths, glycidyl methacrylate (GMA) has been used as the main monomer.16,17 The development of MWCNT based stationary phases with a new monomer, namely 3-chloro-2-hydroxypropyl methacrylate (HPMACl) to achieve multiple separation capabilities is essential for modern LC, especially with respect to nano-LC. A major drawback for the development of nano-LC based monolithic columns has been the limitations of the nano-flow instrument in terms of injection and detection tools. Considering the sensitivity of mass spectrometry, many nano-LC instruments have recently become commercially available. In this regard, the development of monolithic columns at the nano-scale (i.e. 10–100 μm i.d.) for sensitive separations with limited sample amounts (e.g., environmental, proteomics) seems to be an important strategy for selected bioanalytical applications.
The use of antibiotics (e.g. sulfonamides) is widely applied to treat bacterial infections of animals. Similarly, pesticides are widely used for crops at various stages of cultivation.18–20 Maximum residue levels (MRLs) of these compounds are in the range of ng kg−1 to few μg kg−1.5 Therefore, the development of more sensitive analytical approaches for the determination of these compounds at such low levels is of great interest. High resolution orbitrap mass spectrometry (HR Orbitrap MS) is one of the most powerful tools for targeted screening of complex matrices due to its high resolution, high sensitivity and full mass accuracy. Also, the reduction of flow rates in mass spectrometry, in particular in HR Orbitrap MS, offers an enhancement in sensitivity. Improvement in chromatographic separation is the main approach for quantitative LC-MS measurements. The use of nano-LC coupled to MS has been proven to be a better alternative to conventional LC due to faster separation, sharp peak shapes and reduction of organic solvent consumption. Nano-LC based applications with MS have been usually performed using particulate based columns.5,7,19,21–24 Nano-LC instrumentation with new column technology integrating nano-monoliths and nano-ESI spray will make accessible such a sophisticated technique to routine analysis. Up to now, the use of nano LC-MS with a monolith has been restricted to selected relevant applications.25 Considering the advantages of monoliths over their particulate counterparts, the adoption of monoliths to routine applications with nano LC-MS is needed. Therefore, in this work, as a new approach, the preparation of an HPMACl based monolithic stationary phase with incorporated MWCNTs is demonstrated. The monolith exhibited great separation capability for small compounds. In light of the higher UV chromatographic separation capability and great stability observed, parallel investigations were focused on searching for new nano-LC and nano LC-MS techniques, based on a MWCNT based monolith. Encouraged by these results, we used an integrated nano LC-HR Orbitrap MS system for the analyses of antibiotics and pesticides, employing a MWCNT based monolithic stationary phase. This monolith with a nanostructure exhibited great potential for achieving efficient analyses with a high resolution.
500. Extracted ion chromatograms were reconstructed based on ±3 ppm for identification purposes.
:
30% water (v/v) and diluted to a suitable concentration. Isocratic elution was used for the separations. The mobile phase consisted of 75% ACN
:
15% MeOH
:
10% H2O with 3–5% (v/v) formic acid. This mobile phase was used for both nano LC-UV and nano LC-HROrbitrap MS. The injection volume was 1 μL and the flow rate was 800 nL min−1. Before the nano-LC experiment, the monolithic column was equilibrated for 10 min. The temperature of the monolithic column was kept at 20 °C. Milk samples were purchased from different local markets. The samples were filtered through a 0.10 μm membrane. A Captiva ND cartridge was used for the extraction.
The MWCNT content was optimized according to the research reported in recent articles.3,26 The combined total weight was kept constant in order to maintain the same ratio of the monomer (HPMACl) to the cross-linker (EDMA) that is essential to prepare a suitable MWCNT based monolith. The effect of nanotube content in the polymerization mixture on the extent of polymerization was examined. The back pressure and permeability of the columns with different nanotube contents (e.g., 3.7, 5.1, 6.1 wt%) were investigated. The highest degree of polymerization was achieved when 6.1 wt% was employed. With lower content of nanotubes in the polymerization mixture the permeability slightly decreased when compared to the blank monolith. The obtained results may indicate that the degree of macroporosity increased with increasing nanotube content (i.e., 3.7, 5.1, 6.1, wt%). On the other hand, further increase of nanotube content resulted in columns with high pressure, leading to blockage of the flow through macropores and/or destabilization of the monolith structure. The best MWCNT content was found to be 5.1 wt%. The structural morphology of the monoliths was observed by SEM. Comparative images for the columns can be seen in Fig. 1a1, a2, b1 and b2. As can be seen, both the phase ratio and surface area were increased as compared with the blank monolith (Fig. 1b1 with 2500× magnification and Fig. 1b2 with 10000× magnification). The morphology of a monolith tightly coated onto the column could be seen. It is worth noting that increasing the nanotube content in the polymerization mixture under the same conditions produced a dense polymeric layer surface with nanotubes. Based on visual evaluation, there is clearly a difference between the blank monolith (Fig. 1a1) and the nanotube incorporated monolith (Fig. 1b2). This also documents that larger MWCNTs form a thicker and denser layer on the pore surface. The observed dense nanotube layer is a proof that shows an enhancement in the surface area. The nanotube layer thus obtained also allowed the mobile phase to contact a large surface area of the monolith. The results also showed the variation in the morphology of the nanotube layer (Fig. 1a2 and b2). With a higher content of nanotubes in the polymerization mixture (e.g., 6.1 wt%), the permeability of the column was too low for rinsing. This showed that increasing the nanotube content may block the pores of the monolith. The blank HPMACl-EDMA monolith and its counterparts containing 3.7and 5.1 wt% MWCNTs were first prepared in tubes and used for surface area measurements. Nitrogen sorption studies revealed a surface area of 53 m2 g−1 for the blank monolith and 234 and 414 m2 g−1 for MWCNT counterparts, respectively. To compare the monolith incorporated with MWCNTs with the blank monolith, the monoliths were further studied by XRD (see Fig. 1a3 and b3). No increase in the peak intensity at 20–40° (2θ) was observed (see Fig. 1a3) for the blank monolith. However, there was an increase in the peak intensity at 20–40° (2θ) for the nanotube incorporated monolith. This result agreed with that reported in recent studies.27,28Fig. 1b3 shows that MWCNTs are well incorporated within the monolithic structure. The stability of the monolith with nanotubes was tested by measuring the back-pressure values under the same conditions daily. The monolith showed a linear relationship (R2 > 0.9996) between the flow rate and the resulting backpressure. The obtained result shows the good stability of the monolithic column. The incorporation of MWCNTs into the blank monolith afforded an increased efficiency of 48
000 plates per m. The relative standard deviations (RSDs) of the column were evaluated using the retention factor of benzene as a test compound using the mobile phase consisting of ACN/H2O 80/20 (v/v) in an isocratic mode. Run-to-run, day-to-day and column-to-column reproducibility values were less than 2.2%, 3.3%, and 3.6% (n = 5), respectively. The low RSD% values for the reproducibility indicated that this strategy is a reliable method for monolith fabrication. The obtained results also showed that the columns could be prepared and used with satisfactory reproducibility.
:
15% MeOH
:
10% H2O (v/v) was initially tested for the baseline separation of antibiotics. While the blank monolith was not useful for separations in the RPC mode, the MWCNT based monolith exhibited great separation ability towards these compounds. However, the resolution still needed an improvement, which was achieved by exploiting the differences in their pKa values. To achieve an improved separation, differences in their pKa values were exploited. In this regard, formic acid was added to the mobile phase at 5% (v/v), which was composed of 75% ACN
:
15% MeOH
:
10% H2O, and a flow rate of 800 nL min−1 was used for the separation. It was found that this mobile phase increased both the solubility and resolution of the compounds. Fig. 2 illustrates the separation of the compounds using the blank monolith (Fig. 2a) and the MWCNT incorporated monolith (Fig. 2b). As can be seen, the retention time and resolution of the antibiotics improved greatly. In contrast to the monolith without nanotubes, the nanotube counterpart yielded an increased efficiency amounting to 46
000 plates per m for the antibiotics. This confirms that the MWCNT based monolith provided high hydrophobicity originating from the incorporated nanotubes, thus enabling good separation and resolution of the antibiotic compounds. In other words, the improvement in separation represents a proof of the usefulness of the incorporation of nanotubes in enhancing both retention and selectivity.
The use of pesticides is becoming widespread as a result of increasing agricultural productivity. There is a small tolerance policy according to the European Union (Regulation, 2008) (i.e. tolerance policy of up to 1 ppb in agricultural matrices). Despite the small amount, it may cause unexpected hazardous intoxication. Therefore, the development of a sensitive analysis for pesticides is essential. In this respect, the obtained monolith was further applied to the separation of six pesticides, including CH, SM, MT, CY, AT and PR. A mobile phase composition consisting of 50% ACN
:
50% H2O was used for the separation according to the literature.29 The optimal mobile phase conditions with respect to hydrophobic interactions were obtained using a slightly lower ACN content. The best separation was obtained at 60% ACN (v/v) in the mobile phase (Fig. 3a). However, the baseline separation still could not be achieved. When a formic acid solution at 3% (v/v) was added to the mobile phase, the six pesticides eluted between 6 and 14 min with baseline resolution at a flow rate of 800 nL min−1 (Fig. 3b). It is worth noting that the separation mechanism involved the hydrophobic interactions between nanotubes and the pesticide analyte under the optimum RPC conditions. The obtained results demonstrated the successful separation ability of the MWCNT based monolith.
When MS was used, the peaks showed a distorted shape due to the low data rate (see Fig. 4b). This can be explained by the fact that the ionization efficiency may not reach 100% under the operational conditions, as it may get dispersed in charged nanodroplets. This may also show that the ESI ionization in the HR Orbitrap MS may cause a decrease in sensitivity for polar compounds (e.g. sulfamethazine). The results indicated that the retention times of all samples were almost constant under identical chromatographic conditions. Nevertheless, nano LC-HR Orbitrap MS with the MWCNT-based monolith showed high efficiency and sensitivity towards antibiotics and pesticides. Full-MS AIF scan mode allowed for the screening of the compounds. The nano LC-HR Orbitrap MS spectra of sulfapyridine are given in Fig. S1.† As can be seen here, high resolution was observed and the mass error was less than 2 ppm, which was acceptable for the screening. The total ion chromatograms in the case of pesticides are shown in Fig. S2.† A very high sensitivity was observed for the pesticides. By increasing the flow rate, it is possible to reduce the overall analysis time with only a small deterioration in the MWCNT based monolith efficiency. The sensitivity is superior to that reported in previously published papers with packed/monolithic columns.34,35 All these results demonstrated that the MWCNT based monolith has potential applications in the screening of antibiotics and pesticides using an integrated nano LC-HR Orbitrap MS analytical system. The system with the monolith exhibited easy access to routine analysis. The obtained results were also a proof which shows that the nano LC-HR Orbitrap MS system with the novel monolith introduced in this research report may provide the opportunity to analyze several classes of compounds.
![]() | ||
| Fig. 4 (a) Nano LC-UV chromatogram of sulfamethazine. (b) Extracted ion chromatogram of sulfamethazine using nano LC-HR Orbitrap MS. | ||
:
H2O. This was optimized as 60
:
40 v/v. The use of nanospray ionization with the matrix matched calibration curves with appropriate dilutions provided negligible matrix effects. Matrix effects were almost removed for the antibiotics. This was a proof that shows the superior performance for the proposed method. The extraction recoveries ranged from 77 to 89%. The intraday/interday precisions for the samples were in the range of 0.5–11% for all the antibiotics. The LOQ was 0.21 μg kg−1 while the LOD was established at 0.1 μg kg−1 for the compounds.
The obtained results showed that the method with the novel monolith was highly sensitive. The developed method with the novel monolithic column was successfully applied for the determination of antibiotics in milk samples.
000 plates per m for the retained antibiotics. The carbon nanotubes significantly affected the separation performance of the monolith. The separation and analyses were conducted under hydrophobic interaction conditions. Based on the high efficiency in UV-based chromatographic separation, the monolith was used in an integrated nano LC-HR Orbitrap MS system. The use of monolith based nano-LC in combination with HR Orbitrap MS exhibited low limits of detection at the ppb level. This result was due to the use of the nanoscale monolith (75 μm i.d.), which led to increased ionization efficiency that originated from nanospray ionization. Monolithic reproducibility and parameters such as retention time and peak area were also evaluated with satisfactory results. The use of low flow rate (i.e. 800 nL min−1) was also another remarkable advantage related to solvent consumption. The sensitivity of the proposed method with the novel monolithic column was satisfactory. Monolith based nano LC-HR Orbitrap MS could be applied to routine residue analysis with high sensitivity (at the ppb scale) and reproducibility.
Footnote |
| † Electronic supplementary information (ESI) available. See DOI: 10.1039/c8ay02173b |
| This journal is © The Royal Society of Chemistry 2019 |