Polar–nonpolar interconnected elastic networks with increased permittivity and high breakdown fields for dielectric elastomer transducers

C. Racles*a, A. Belea, M. Dascalua, V. E. Musteataa, C. D. Varganicia, D. Ionitaa, S. Vlada, M. Cazacua, S. J. Dünkib and D. M. Opris*b
aPetru Poni Institute of Macromolecular Chemistry, Aleea Grigore Ghica Voda 41A, Iasi, 700487, Romania. E-mail: raclesc@icmpp.ro
bEmpa, Swiss Federal Laboratories for Materials Science and Technology, Laboratory for Functional Polymers, Ueberlandstr. 129, CH-8600, Dübendorf, Switzerland. E-mail: Dorina.Opris@empa.ch

Received 16th April 2015 , Accepted 30th June 2015

First published on 30th June 2015


Abstract

Elastic materials with increased permittivity (ε′) were obtained in a three-step process starting from a hydroxyl end-functionalized polydimethylsiloxane (PDMS) of a high molecular weight (Mw = 139 kDa), trimethylsilyl end-blocked silicones that carry hydrosilane, cyanopropyl and hexyl groups Px (where x represents the mol% of cyanopropyl groups), and tetraethoxysilane (TEOS). The hydrosilane groups of Px were first hydrolyzed and the formed hydroxyl groups were subsequently reacted with partially hydrolyzed TEOS and further used as high ε′ components, cross-linkers, and reinforcing agents for the PDMS matrix. A high wt% of the polar component Px was incorporated into the nonpolar PDMS matrix by forming interconnected networks. Thermal (DSC, DMA) and morphological investigations (SEM) show the biphasic morphology of the networks. The dielectric, mechanical, and electromechanical properties of the films were investigated. Materials with good elastic properties, increased ε′, and a high breakdown field (Eb) were obtained. The best material has an elastic modulus of 800 kPa at 10% strain, an ε′ = 4.5, and a maximum actuation strain of 8% at Eb = 56 V μm−1.


Introduction

Dielectric elastomer transducers (DET) are devices able to convert electrical energy to mechanical energy or vice versa.1 DET are finding applications in robotics2–6 artificial muscles7,8 medical devices,9–13 replacements of space engines14,15 or in energy harvesting from different sources like wind,16 human motion,17,18 or waves.19–21 As dielectrics, several elastomers such as silicones, polynitrile, polyacrylate, and natural rubbers as well as composites thereof have been used.22,23

The transducer performance is directly influenced by the stiffness and the permittivity (ε′) of the dielectric. Large actuation strains are expected for materials that have a high ε′ and a low elastic modulus. However, in terms of stress, a low elastic modulus (Y) value is not always of advantage, since the maximum stress attainable in an actuator increases for stiff materials.21

Silicones are characterized by a high flexibility of the Si–O bond,24,25 which is responsible for the large achievable strains. Additionally, they are biocompatible, resistant to weathering, and have stable properties over a wide range of temperatures and frequencies.26,27 Furthermore, silicones have good dielectric strength typically over 100 V μm−1 and maintain their specific energy over a wide frequency domain.28 Despite of these great properties, silicones have a low ε′ of less than 3.

The application potential of dielectric silicone materials would increase significantly if ε′ could be increased while keeping the breakdown field strength and the elastic moduli at reasonable values. Attempts to increase the ε′ of silicones include blending it with polarizable particles or with a polar component, chemical modification with polar side groups, or using a polar cross-linker.29–32

When polar cross-linkers are used, homogenous silicone elastomers form, but unfortunately the increase in the ε′ is low due to the limited amount of polar groups that can be incorporated.32

A larger degree of functionalization of silicones can be achieved when the Si–O repeating units comprise a polar group.33,34 Cyanopropyl-modified silicones were recently used as fillers in a silicone elastomer matrix31 cross-linked by hydrosilylation. Composites with polar filler content up to 39 wt%, that reached ε′ values as high as 7 were reported. However, the breakdown field (Eb) decreased significantly with increasing the ε′. Blending allows formation of materials with a polar phase physically dispersed into a nonpolar matrix. However, when the filler is not chemically bonded to the matrix, it can leak or can be extracted from the film, which leads to deterioration of the dielectric as well as mechanical properties in time.

We previously described the synthesis of nitrile containing silicone materials by cross-linking of copolymers containing different mol% of cyanopropyl groups and hydroxyl end-groups.34 Materials with ε′ as high as 6.5 but rather poor elastic properties formed. To improve on this, the modified copolymers were used as high ε′ components in a PDMS matrix with suitable mechanical properties. To avoid phase separation, a fast cross-linking reaction was used.34 This simple method allowed cross-linking the homogenous solution and macro-phase separation was avoided. Unfortunately, the amount of polar material incorporated into the PDMS matrix was rather low and therefore the maximum achieved permittivity was only ε′ = 3.5. Recently, a series of polymers containing various amounts of nitrile groups was reported and the dielectric properties of the formed polymers were investigated. The hydrosilylation was incomplete and some residual Si–H groups were still present.35 Although disappointing, these results suggest that it might be possible to use the unreacted Si–H groups in subsequent reactions.

Thus, it was the aim of the present work to develop a synthetic strategy to elastomers that incorporate large amounts of polar cyanopropyl modified silicones by chemically bonding them to a nonpolar PDMS matrix. For this, trimethylsilyl end-blocked polysiloxanes Px containing different proportions of cyanopropyl (x mol%), hexyl and Si–H groups were used as polar components.35 The unreacted Si–H groups of Px were used to interconnect Px with the hydroxyl end-groups of PDMS, in a three-step process, which involves hydrolysis and condensation reactions, leading to polar–nonpolar interconnected networks. These reactions were carefully followed step by step by FT-IR. The thermal, dielectric and mechanical properties of the obtained films, as well as their morphology, were investigated by a combination of techniques: DSC, DMA, impedance spectroscopy, tensile measurements, fatigue tests, SEM. Their actuation performance was tested in circular membrane actuators.

Experimental

Materials and methods

The following reagents were used as received: a linear hydroxyl end-functionalized PDMS (Mw = 139 kDa) from ABCR, tetraethyoxysilane (TEOS) from Fluka, and dibuthyltin dilaurate (DBTDL) from Sigma-Aldrich. Tris(hydroxymethylaminomethane)-end-functionalized PDMS oligomer with 19 dimethylsiloxane units was prepared following our previously reported method36 and used as non-aqueous surfactant. All solvents were reagent grade and used as received.

The infrared spectra were recorded on a Bruker Vertex 70 FT-IR instrument, in transmission mode, in the 300–4000 cm−1 range (resolution 2 cm−1, 32 scans), at ambient temperature. Differential scanning calorimetry (DSC) investigations were done on a Pyris Diamond DSC (Perkin-Elmer USA) instrument. NMR measurements were conducted on a Bruker Avance III 400 NMR spectrometer using a 5 mm BBO Prodigy™ CryoProbe at 400.18, 100.63 and 79.50 MHz, respectively. For SEM investigation, the films were fractured in liquid nitrogen and the cross-section surface was examined with an Environmental Scanning Electron Microscope (ESEM) type Quanta 200, operating at 30 kV with secondary electrons. Dynamic mechanical analysis (DMA) measurements were conducted on a Perkin-Elmer Diamond DMA instrument, in tension mode, under nitrogen atmosphere. Temperature scans were performed on films with dimension of 9 × 9 × 0.4 mm3 at a heating rate of 2 °C min−1 from −150 °C to 200 °C and at 1 Hz. The values of the storage modulus (E′), loss modulus (E′′) and loss factor (tan[thin space (1/6-em)]δ) were obtained as a function of temperature. Relaxation temperatures were evaluated from the drop in E′ curves and from the peaks in E′′ and tan[thin space (1/6-em)]δ. The tensile tests were performed using a Zwick Z010 tensile test machine with a crosshead speed of 500 mm min−1. Tensile test specimens with a gauge width of 3 mm and a gauge length of 30 mm were prepared by die cutting. The strain was determined by a Zwick video extensometer 066975. The curves were averaged from 3 to 5 independent experiments. The tensile modulus was determined from the slope of the stress–strain curves using a linear fit to the data points within 10% strain. To evaluate the mechanical fatigue resistance, cyclic tests were performed on a TIRA test 2161 apparatus, Maschinenbau GmbH Ravenstein, Germany. Five cycles were run with a stationary time at maximum strength of 5 s, stationary time at minimum strength of 5 s, maximum strain of 100%, and minimum strain of 8%.

The complex dielectric permittivity at room temperature was recorded by sweeping frequency from 1 to 106 Hz, using a Novocontrol Dielectric Spectrometer equipped with frequency response analyzer. The samples were prepared by sputtering gold electrodes with a diameter of 20 mm. The breakdown experiments were conducted with a setup similar to that described by Kollosche et al.37 About 10 measurements were done for each sample and the data were averaged. The electromechanical tests were performed using circular membrane actuators, for which the films were prestrained to about 12% and fixed between two circular frames. Circular electrodes (8 mm diameter) of carbon black powder were applied to each side of the film. A FUG HCL-35-12500 high voltage source served as power supply for actuator tests. The voltage was increased by 100 V every 2 s up to breakdown. The actuation strain was measured optically as the extension of the diameter of the electrode area via a digital camera, using an edge detection tool of a LabView program to detect the boundary between the black electrode area and the transparent silicone film.

Synthesis of Px

Trimethylsilyl end-blocked silicones Px, where x represents the mol% of cyanopropyl groups were prepared according to35 by hydrosilylation of poly(methylhydro)siloxane with allyl cyanide and 1-hexene in different proportions. Px have various content of cyanopropyl and hexyl groups as well as some unreacted hydrosilyl groups. The composition of Px is given in Table 1.
Table 1 Composition and dielectric permittivity at 10 kHz of Px
Polar silicone aCyanopropylmethyl siloxane unit [% mol] aHexylmethyl siloxane unit [% mol] aH-Si unit [% mol] ε′ at 10 kHz
a As determined by 1H NMR spectroscopy.
P89 89 11 15.9
P62 62 26.9 11.1 11.3
P10 10 78.7 11.3 3.7
P0 98.5 1.5 2.7


Synthesis of materials Px(y/z)

Interconnected networks between a polar Px component and a nonpolar PDMS matrix were prepared and named as Px(y/z), where Px is the polar component used and y/z indicate the mass ratio of Px to PDMS. The amount of reagents used for the synthesis of materials Px(y/z) is given in Table 2.
Table 2 The amount of reagents used for the synthesis of materials Px(y/z)
Sample PDMS [g] Px [g] TEOS [mL] Sn-cat. [g] Px [wt%] CN group [wt%]
P89(1/2) 1 0.5 0.8 0.025 28.6 5.33
P62(1/2) 1 0.50 0.80 0.1 27.0 3.33
P10(1/2) 1 0.50 0.80 0.1 27.0 0.47
P0(1/2) 1 0.50 0.80 0.1 27.0 0.00
P89(1/3) 1.5 0.5 1.10 0.025 21.5 4.00
P62(1/3) 1.5 0.50 0.80 0.1 21.5 2.73
P10(1/3) 1.5 0.50 0.80 0.1 21.5 0.37
P0(1/3) 1.5 0.50 0.80 0.1 21.5 0.00
P62part(1/2) 0.3 0.15 0.12 0.025 28.4 3.50


Below, the synthesis of P10(1/2) and its thin film formation is described:

(a) To a solution of copolymer P10 (0.5 g) in chloroform/methanol 1/1 (2 mL), DBTDL (0.1 mL) was added. The solution was stirred in an open vessel at room temperature. Chloroform was added when the solution became turbid, which indicates an excess of methanol (bad solvent). This procedure was repeated until no turbidity was observed, which took about 1 h.

(b) To the resulting solution, TEOS (0.8 mL) was added and the mixture was stirred at 40 °C for 15 min.

(c) Finally, a solution of PDMS (1 g) in chloroform was added and the mixture was stirred for about 5 min to obtain a homogenous solution. To remove the air bubbles this solution was sonicated for 1 min. Films were made on a Teflon substrate using doctor blade technique.

Synthesis of P62part(1/2)

A mixture of copolymer P62 (0.15 g) and one drop of DBTDL in a solution of methanol and THF (1/1 v/v) (1 mL) was stirred in an open vessel for 30 min. Then TEOS (0.04 mL) was added and the reaction mixture was stirred at 40 °C for another 10 min. This solution was injected into a 1% solution of surfactant in toluene (2 mL). The methanol, THF and about half of toluene were removed under vacuum and the remaining solution was added to a solution of PDMS (0.3 g) in toluene (1 mL). Then TEOS (0.08 mL) and one drop DBTDL were added followed by vigorous stirring for a few minutes. Films were prepared by casting on a Teflon substrate.

Results and discussion

Synthesis of polar-nonpolar interconnected elastic networks

We have recently described the synthesis of a series of cyanopropyl/hexyl modified polysiloxanes Px with varying mol% of polar cyano groups35 by (co-)hydrosilylation reactions of a trimethylsilyl end-blocked poly(methylhydro)siloxane (Mw ca. 2000 g mol−1) with a mixture of allyl cyanide and 1-hexene. An increase in the permittivity with increasing the amount of polar cyano groups from ε′ = 2.7 for P0 to ε′ = 15.9 for P89 (Table 1) was found. Because the molecular weight of Px was rather low, cross-linking of Px does not allow formation of materials with good elastic properties. However, the appropriate cross-linking of Px with a high Mw PDMS might allow formation of materials with increased ε′ and improved mechanical properties. Thus, it was the aim of this work to develop a synthetic strategy to interconnected Px/PDMS elastomers and to investigate how the amount of polar groups in Px influences the dielectric, mechanical, and electromechanical properties of the formed materials.

Although copolymers containing different mol% of cyanopropyl groups can also be prepared starting from poly(dimethyl-methylhydro)siloxane, several disadvantages can be noted when such copolymers are used. First, the poly(dimethyl-methylhydro)siloxanes with varying content of methylhydrosiloxy groups have to be prepared starting from a mixture of D4 and D4H. This is time consuming, since the reaction conditions for each individual copolymer has to be first found. Furthermore, a systematic investigation of the influence of different cyanopropyl modified polymers on the properties of the resulting materials is not possible since they have different molecular weights and distributions. In addition, for trimethylsilyl-end blocked copolymers, the presence of a similar number of unreacted Si–H groups should be ensured within a series for a systematic investigation. By using poly(methylhydro)siloxane and a mixture of allyl cyanide and 1-hexene, polymers that have the same chain length and dispersity and tunable dielectric properties are formed. In this approach, 1-hexene was a convenient liquid reagent used to ensure the same conversion within a series of copolymers with polar group content varying within a very wide range. Due to the low reactivity of allyl cyanide in the hydrosilylation, the conversion of the Si–H was not quantitative (about 10 mol% of Si–H were still found in the final polymers). When only 1-hexene was used for the hydrosilylation of poly(methylhydro)siloxane, the conversion of the Si–H groups was almost quantitative (P0). By using a three-step process, it was possible to incorporate a large amount of Px into PDMS, whereby the macroscopic phase separation was avoided. Materials Px(y/z), where y/z represents the weight ratio of Px/PDMS were prepared (Table 2). P0 has no cyano groups and served as reference, while P89, P62 and P10 were used as high ε′ components. In the following, it will be shown how the unreacted Si–H groups of Px were used to anchor Px to the PDMS matrix.

In our previous work, we observed that when a hydroxyl end-functionalized poly(dimethyl-methylhydro)siloxane was hydrosilylated with allyl cyanide, a spontaneous cross-linking of copolymers occurred.34 It was presumed that a condensation between the hydroxyl end-groups and the unreacted residual Si–H groups catalyzed by Pt occurred. Our attempts to avoid this side reaction by replacing the hydroxyl end-groups by trimethylsilyl were not successful.35 When Px or their solutions in toluene were kept in normal atmosphere, an insoluble cross-linked material formed. The 29Si NMR spectrum of this cross-linked material swollen in CDCl3 shows the presence of the “T”-type Si formed from two Si–H groups via a hydrolysis followed by a condensation step (Fig. S1). Although at first hand this was disappointing, we decided to use this side-reaction in our advantage. The FT-IR spectra of these cross-linked materials show that the vibration band at 2154 cm−1 typical for Si–H groups disappeared after few months. It is known that the Si–H bond hydrolyses slowly in presence of moisture and fast in presence of bases.26 The cross-linking of Px is most likely due to the hydrolysis of the Si–H groups to Si–OH followed by a spontaneous dehydration between two Si–OH groups and/or a dehydrocoupling between the formed Si–OH and the remaining Si–H groups. The latter reaction is favored by the presence of traces of Pt or Sn catalyst. Based on these observations, a three-step process for the synthesis of polar-nonpolar interconnected elastic networks was developed (Scheme 1):


image file: c5ra06865g-s1.tif
Scheme 1 Schematic illustration of the three-step process used for the formation of polar–nonpolar interconnected silicone elastomers.

(a) The hydrolysis of Si–H groups of Px in a solution of chloroform–methanol in the presence of DBTDL and atmospheric moisture.

(b) The hydrolysis of TEOS and condensation of the formed Si–OH groups to generate silica in situ and to anchor Px.

(c) The condensation of the hydroxyl end-groups of PDMS with the hydroxyl groups of the polar component obtained in step (b).

As these condensation reactions are rather slow, maturation in time is necessary as a final step.

To monitor the evolution of the reaction stepwise, a kinetic survey at various moments of the process was done by FT-IR. The changes of a solution of P62 in a mixture of chloroform-methanol in the presence of DBTDL were observed. Aliquots were taken from time to time and the changes in the Si–H stretching band at 2154 cm−1 were followed while the Si–CH3 symmetric band at 1260 cm−1 was taken as reference (Fig. S2). After about 1 h, the Si–H band decreased to half. The residual Si–H groups are sterically hindered and therefore less reactive. Additionally, the vicinity of hydrophobic methylsiloxane groups makes the hydrolysis more difficult. It is therefore not surprising that this hydrolysis step is rather slow. As mentioned before, P89, P62 and P10 contain around 10% un-modified Si–H groups which represent 3.3 groups in average per polymer chain. After 1 h, about 50% of these groups were hydrolyzed. In principle, even if only a single Si–H group per copolymer chain would react, this would be sufficient to anchor Px to the PDMS but does not ensure its use as sole cross-linker for PDMS in a 3D network. If the reaction time is increased, the condensation process occurs simultaneously, leading to self-cross-linking of Px.

Therefore, the total cross-linking capacity of the polar phase was increased by adding TEOS in the second step, which easily hydrolyzes in atmosphere. The FT-IR spectra (350–1300 cm−1 region) of the hydrolysis and condensation processes in steps (a) and (b) are compared with that of the polar copolymer P62 in Fig. 1. The starting P62 shows the well-known Si–O–Si absorption pattern consisting of two broad and strong symmetric bands at 1021 and 1096 cm−1, respectively. After the first step, this region of the spectrum changed. Three bands were present at 1015, 1085 and 1110 cm−1 and an asymmetric pattern was observed. This asymmetry is specific to so-called “hydrolyzed” trifunctional siloxanes.38 Apart from the modifications of the siloxane region, the spectrum of the hydrolyzed P62 shows an absorption band at 966 cm−1 characteristic for Si–OH groups38 which is not present in the starting copolymer. After TEOS addition, the condensation reaction started. The spectrum shows smoothening of the asymmetric pattern and a broadening of the entire siloxane region (1000–1130 cm−1). These important changes in the spectrum indicate the formation of a 3D silica-like network. Additionally, the stretching band at 966 cm−1 characteristic to the Si–OH bond remains as a shoulder.


image file: c5ra06865g-f1.tif
Fig. 1 Comparison of FT-IR spectra (350–1300 cm−1 region) of the polar copolymer component at different stages: P62 just after the synthesis (dotted line), after the hydrolysis-step (a) (thin line), and after the condensation-step (b) (bold line).

In the third step the condensation of the hydroxyl end-groups of PDMS with the hydroxyl groups of the polar component occurred. Thin films were then formed by doctor blade technique on a Teflon substrate. After evaporation of the solvent and finalization of the condensation process, the films were peeled off the substrate. The un-hydrolyzed Si–H groups that were still observed in the cross-linked film slowly hydrolyzed over time under atmospheric humidity; however this process is slow and can take weeks or even months. An example is shown in Fig. S3, where the gradual decrease of the Si–H absorbance within three weeks was observed. Therefore, the film formation process requires maturation. Although a simple procedure is used, the cross-linking in the film is a rather complex process, which involves hydrolysis and condensation reactions which finally lead to interconnected networks. The condensation reactions can occur between the hydroxyl groups formed by hydrolysis of TEOS, those present in Px after step (a) and the hydroxyl end-groups from PDMS matrix (Scheme 1).

Due to the remaining Si–H groups, one may think that the polar Px could be used alone to cross-link the PDMS. However, according to literature31 and our own experiments, the hydrosilylation reaction in this particular case was not successful, probably due to steric hindrance. Moreover, if Px is used as cross-linker, stoichiometric amounts would be used, which would allow incorporation of only about 3 wt% of polar component Px into the materials. This amount of polar Px component would be too low to induce a significant increase in the permittivity of the PDMS matrix. Furthermore, if excess of polar Px is used without ensuring conditions for its cross-linking during film formation, the polar phase is not chemically bonded to the PDMS matrix and therefore macrophase separated materials form (an example is shown in Fig. S4). By using TEOS which functions as an interconnecting agent between the polar and nonpolar components, the phase separation can be controlled. Additionally, the excess of TEOS allows in situ formation of silica, which reinforces the materials.

The amount of extractable species in THF was about 8% for the materials P62(1/2). 1H NMR spectrum (Fig. S5) shows that a mixture of compounds: DBTDL catalyst, some oligodimethylsiloxane and P62 was extracted. According to the 1H NMR spectrum, the amount of P62 was ca. 7% in the extract, which represents about 0.5% P62 that is not interconnected into the network. Since the characteristic signal for Si–H protons is not present in the 1H NMR spectrum of the extract, it might be that a small fraction of P62 had a complete conversion of the Si–H groups in the hydrosilylation.

Characterization of the films

SEM investigations conducted on cryo-fractured films, clearly showed phase separation with globular domains. Fig. 2 shows four representative SEM images of materials P89(1/2), P62(1/2), P10(1/2), and P0(1/2). Phase separation is a common phenomenon in poly(dimethylsiloxane) copolymers or blends,39,40 since PDMS is incompatible with practically any organic polymer. As a consequence of this incompatibility, phase separation was observed not only for the highly polar copolymers P89, P62 and P10 but also for P0 which contains long aliphatic branches. However, an interesting aspect is that the morphology is uniform over the entire thickness of the film and no layering was observed. When the polar copolymer was blended in PDMS without being cross-linked, the resulting material had a completely different aspect, with macroscopic phase separation (Fig. S4), due to the different polarity and density of the components. Therefore, the morphology observed for Px(y/z) films supports the idea of interconnected networks.
image file: c5ra06865g-f2.tif
Fig. 2 SEM images of the cryo-fractured films: P89(1/2)-(a), P62(1/2)-(b), P10(1/2)-(c), and P0(1/2)-(d). Size bar represents 100 μm.

To further reduce the polar domains in our materials, particles of cross-linked P62 were prepared by precipitation technique as described in the experimental part. These particles were incorporated in a solution of PDMS and cross-linking reagents in toluene under stirring. A film of the above mixture was casted on a Teflon substrate (sample P62part(1/2)). The SEM image of this material (Fig. S6) showed that submicron particles are dispersed within the matrix, which represents a reduction of the polar domains roughly by a factor of 10. However, P62part(1/2) is a blend, since the polar and nonpolar phases are not chemically bonded.

The DSC analysis of the interconnected networks revealed two glass transition temperatures (Tg) irrespective of the composition of the films (Table 3). The presence of two Tgs indicates that the materials are biphasic. The lower value Tg1 corresponds to the nonpolar silicone phase and is generally higher than in neat PDMS (−124.5 °C), while the other value, Tg2, is assigned to the respective polar component.

Table 3 Thermal behavior of Px(y/z) as determined by DSC
Film Tg of Px, °C (ΔCp, J g−1 K−1) Tgs in film (°C) Tm (°C)
Tg1 (ΔCp, J g−1 K−1) Tg2 (ΔCp, J g−1 K−1) Calcd ΔCp(2)a J g−1 K−1
a Calculated according to the composition, with the formula: % Px·ΔCp(Px).
P89(1/2) −62.1 (0.338) −123.6 (0.027) −63.2 (0.051) 0.097 −42
P89(1/3) −121.8 (0.029) −60.6 (0.039) 0.073 −40
P62(1/2) −75.6 (0.344) −118 (0.045) −88 (0.08) 0.092 −45
P62(1/3) −117 (0.034) −88.4 (0.06) 0.075 −44
P10(1/2) −103 (0.43) −117 (0.005) −95 (0.054) 0.116 −44
P10(1/3) −122 (0.032) −108 (0.08) 0.092 −44
P0(1/2) −111.3 (0.405) −121 (0.081) −111 (0.063) 0.11 −43.5; −9
P0(1/3) −119 (0.038) −111 (0.072) 0.087 −42.3; −9


The absolute heat capacity characterizes energetically the movement of chain segments. Cross-linking leads to reduction in free volume between chain segments. In a cross-linked material, the movement of the chain segments is sterically hindered, which lowers the absolute heat capacity values.41,42 In our case, ΔCp = 0.306 J g−1 K−1 for the pristine, un-cross-linked PDMS. The content of PDMS in our materials, calculated by taking into account all the components (PDMS, polar silicone, catalyst and silica resulted from full hydrolysis and condensation of the excess TEOS) is ca. 55% for Px(1/2) films and ca. 65% for Px(1/3) films. The theoretical values for ΔCp(1) in the films were: 0.165 J g−1 K−1 for Px(1/2) and 0.2 J g−1 K−1 for Px(1/3). The theoretical ΔCp values for Tg2 were also calculated (column 5 in Table 3), from ΔCp of the corresponding un-cross-linked copolymer (second column) and the composition of the films. As can be observed in Table 3, the experimental ΔCp values of the new materials for both Tgs are lower as compared to the calculated values. This indicates that the macromolecular chains have diminished mobility, which supports the cross-linked state of PDMS and of Px in the films. As an example, Fig. S7 compares the DSC curve of P10(1/2) with that of P10 and PDMS.

During the heating scan, a melting endotherm was observed between −42 and −45 °C, but no cold crystallization (as observed for PDMS – Fig. S7). The formation of crystalline domains was registered during the cooling scan between −75 and −73 °C (not shown). These transitions were assigned to the nonpolar component since their values are close to the values of neat PDMS, i.e. −44 °C melting (heating scan) and −82 °C crystallization (cooling) and neither melting nor crystallization phenomena were detected for Px. For materials P0(y/z) additional transitions were observed: melting at around −9 °C (heating scan) and crystallization at −37 to −40 °C (cooling scan). Since P0 didn't exhibit such transitions, they might be due to differently organized domains in PDMS, as suggested by Sundarajan.43 On the other hand, we cannot exclude that crystallization of the poly(methylhexyl)siloxane might be favored in the cross-linked materials. As mentioned before, polymer P0 contains only few unreacted Si–H groups. Following the rational of the cross-linking process, described above, it is unlikely for materials P0(y/z) to cross-linking via P0. Despite of this, no macroscopic phase separation or exudation was observed. In addition, even though the Tg2 value is close to that of the neat polymer, the corresponding ΔCp values are lower than the calculated ones. This is an indication that the chains participate in the cross-linking reaction during film formation which limits chain motion.

Material P62(1/2) was analyzed by DMA. Its viscoelastic behavior is characterized by a glassy region (T > −140 °C) with a storage modulus in the order of 109 Pa, followed by a two-step decrease of the storage modulus up to −50 °C (Fig. S8). The decrease of the storage modulus is less than one order of magnitude in the Tg region and the low value of tan[thin space (1/6-em)]δ peak height indicate the presence of constraints that hinder the large movement of chain segments. These constrains are on one hand the cross-linking points, and on the other hand, the crystalline domains confirmed by the DSC measurements. At −38 °C an abrupt descent in E′, more than three orders of magnitude over a narrow temperature range was observed, until a plateau marks the melting of the crystalline phase. The storage modulus reaches a plateau that has the magnitude of 104 Pa, which is comparable with the values previously obtained for medium weight PDMS–silica cross-linked films.44 The low value of the storage modulus indicates that soft materials are formed.

The mechanical properties of Px(y/z) and a reference cross-linked PDMS film obtained with the same ratio of cross-linking reagents, were evaluated in tensile tests. The stress–strain curves are represented in Fig. 3, while in Table 4 the Young's moduli, maximum stress and deformation are collected. A large excess of TEOS was used in all the films, including the PDMS reference, i.e. ca. 50 wt% reported to the polymers. It is therefore not surprising that our PDMS matrix (reference) is rather stiff with a maximum strain of 154% and a maximum stress of 3.2 N m−2. Materials Px(y/z) were softer than the PDMS reference. The lowest value for maximum strain was 170% for P62(1/2), while all the other samples gave values between 200 and 270%. The obtained materials have Young's modulus at 10% strain that ranges between 0.4 and 1.5 MPa, and maximum stress roughly between 0.5 and 2 MPa. Materials Px(1/2) have a lower strain at break as compared to materials Px(1/3). The mechanical properties of material P62part(1/2) were different from those of P62(1/2) that has the same amount of polar phase incorporated, i.e. the tensile strength increased significantly, the strain at break also increased (to 250%, from 170%), and Y decreased to 0.48 MPa (from 0.8 MPa).


image file: c5ra06865g-f3.tif
Fig. 3 Stress–strain curves of Px(y/z) and PDMS film.
Table 4 Mechanical properties of Px(y/z) and PDMS reference film
Sample Young's modulus (MPa) Tensile strength [MPa] Elongation at break [%]
10% 20% 50% 100%
P89(1/2) 0.43 0.57 0.46 0.55 0.49 206
P89(1/3) 0.65 0.47 0.26 0.53 0.60 225
P62(1/2) 0.80 0.69 0.52 0.67 1.07 170
P62(1/3) 0.75 0.62 0.41 0.39 1.02 208
P10(1/2) 0.89 0.75 0.57 0.87 1.88 200
P10(1/3) 0.71 0.59 0.38 0.44 1.52 266
P0(1/2) 0.47 0.42 0.34 0.39 0.88 199
P0(1/3) 0.52 0.46 0.33 0.37 0.99 227
PDMS 1.37 1.32 2.82 2.27 3.20 154
P62part(1/2) 0.48 0.45 0.46 0.70 1.71 247


A plasticizing effect of Px on the PDMS matrix was observed for all the interconnected networks. Such effect was reported before for blends and was assigned to the additional volume of the dispersed phase,31,45 when the phases were mixed in solution.

Cyclic tests were performed on samples P62(1/2) and P10(1/2) to evaluate the mechanical fatigue resistance. The tests prove the elastic behavior of the elastomer films, with a hysteresis loop only at the first strain-release cycle and a small difference between cycles (Fig. S9).

The dielectric properties of the cross-linked films were investigated by dielectric relaxation spectroscopy at room temperature between 1 and 106 Hz. Fig. 4 shows the variation in ε′, dielectric loss (ε′′), loss factor (tan[thin space (1/6-em)]δ) and conductivity (σ) for materials Px(y/z) and the PDMS reference film. Table 5 summarizes the dielectric properties at 10 kHz. Compared to the reference PDMS film (ε′ = 2.6), all materials Px(y/z) show an increase in permittivity, up to ε′ = 4.9 for P89(1/2). The conductivity values at low frequencies are between 5 × 10−12 and 5 × 10−11 S cm−1, while the dielectric losses at high frequencies are rather low. Materials P89(y/z) and P62(y/z) show a relaxation peak between 50 Hz and 1 kHz which results in an increase in the ε′. This relaxation peak might be due to interfacial polarization which occurs at low frequencies.46 A ε′ increase at low frequencies was observed for all samples which is most likely due to electrode polarization.


image file: c5ra06865g-f4.tif
Fig. 4 Dielectric permittivity (ε′), dielectric loss (ε′′), loss factor (tan[thin space (1/6-em)]δ) and conductivity (σ) of Px(y/z) and of the PDMS matrix as function of the frequency.
Table 5 Dielectric properties, actuation strain (s) at 30 V μm−1, maximum actuation strain (smax), the dielectric breakdown in actuator (Eb), and the dielectric strength (EEB) for Px(y/z), P62part(1/2) and PDMS reference
Sample ε′ (10 kHz) ε′′ at (10 kHz) σ (10 kHz) [S cm−1] s [%] at 30 V μm−1 smax [%] Eba [V μm−1] EEBb [V μm−1]
a Eb for actuator measurements using a carbon black electrode with a diameter of 8 mm.b EEB of the material using 1 mm2 electrodes.37
P89(1/2) 4.9 0.177 9.9 × 10−10 1.7 19 29
P89(1/3) 4.2 0.079 4.4 × 10−10 1.5 25 34
P62(1/2) 4.5 0.095 5.3 × 10−10 1.9 8 56 61
P62(1/3) 4 0.145 8.1 × 10−10 2.2 3.2 34 58
P10(1/2) 3 0.015 8.3 × 10−11 1.1 5.6 59 61
P10(1/3) 2.9 0.012 6.9 × 10−11 1.3 3.3 47 71
P0(1/2) 2.7 0.009 5.2 × 10−11 3.5 4.4 34 54
P0(1/3) 2.5 0.008 4.3 × 10−11 2.1 2 31 62
P62part(1/2) 3.8 0.045 2.2 × 10−10 3 3.6 31.5 65.4
PDMS 2.6 0.003 1.7 × 10−11 0.3 0.6 49 128


Electromechanical performances

The new materials were also investigated in electromechanical tests using circular actuators. An increasing voltage step was applied to the samples until a breakdown through the material occurred. The measured actuation strains of the materials are shown in Fig. 5 and compared with the PDMS reference. Table 5 summarizes the maximum actuation strain, the breakdown field of the actuator, the dielectric breakdown, and the actuation strains at 30 V μm−1 for all materials. The largest lateral actuation strain at 30 V μm−1 was obtained for material P0(1/2) (3.5%) which was the softest of the materials that withstand this field, while the highest maximum lateral actuation strain of 8% was obtained for P62(1/2) at 56 V μm−1. The obtained strain values are roughly 12 or 13-times higher as compared to the PDMS reference. The highest actuation strain at the lowest electric field was observed for material P89(1/2) with an smax = 1.6% at 18.5 V μm−1.
image file: c5ra06865g-f5.tif
Fig. 5 Lateral actuation strain of circular actuators of materials Px(y/z), P62Part(1/2) and PDMS reference as a function of applied electric field.

Irrespective of the type of polar polymer Px used, materials Px(1/2) show an increase in the breakdown field and an increase in the maximum achievable lateral strain as compared to materials Px(1/3). Material P89(1/2) has slightly lower breakdown field in actuator but a larger actuation strain at a certain voltage as compared to P89(1/3). Material P62(1/2) has a maximum actuation strain (smax) of 8% at Eb = 56 V μm−1, while material P62(1/3) has a much lower smax (smax = 3.2%) at Eb = 34 V μm−1. The same trend was observed for sample P10(1/2) with a smax = 5.6% at Eb = 59 V μm−1, while material P10(1/3) had a smax = 2% at Eb = 30 V μm−1.

The actuation strains at 30 V μm−1 (see Table 5) for materials Px(1/3) are only slightly higher than for materials Px(1/2), despite that Px(1/3) are softer as compared to Px(1/2). These small differences are due to the higher ε′ observed for materials Px(1/2) which compensate the increase in the elastic moduli. Since the stress–strain curves of materials P62(1/3) and P10(1/3) were superimposable, a direct comparison of the effect of ε′ on the actuation is possible. Material P62(1/3) has an ε′ = 4 and an actuation strain of 3.2% at 34 V μm−1, while material P10(1/3) has an ε′ = 2.9 and an actuation strain of 1.6% at the same electric field. The better performance in the actuation strain for material P62(1/3) as compared to P10(1/3) is due to the higher ε′. The actuation curves for materials P62(1/2) and P0(1/3) are also superimposable despite that material P62(1/2) has a higher elastic modulus as compared to P0(1/3) (0.8 MPa and 0.52 MPa, respectively). Also here, the improved actuation performance of P62(1/2) is due to the higher ε′.

When preformed polar particles were blended in the PDMS matrix as was the case for material P62part(1/2), the actuation strain at 30 V μm−1 increased as compared to the interconnected network with similar composition P62(1/2). However, the electrical breakdown in the actuator occurred at lower voltage and the maximum actuation strain decreased.

It is worth mentioning that the breakdown in actuator for the networks with high content of polar components P62(1/2) and P10(1/2) is higher than for the PDMS reference.

The breakdown fields of the materials Px(y/z) were lower as compared to the PDMS reference (Table 5). The EEB of the PDMS was 128 V μm−1, while the breakdown of materials Px(y/z) occurred at approximately half of the field supported by pristine PDMS, e.g. all materials Px(y/z) have EEB between 54 and 71 V μm−1, except for materials obtained with P89. These are high values, comparable with those recently reported for polysiloxanes modified with 1-ethynyl-4-nitrobenzene.30

A direct comparison between the performance of materials Px(y/z) and that of other similar materials reported in the literature is difficult to be done since detailed description of the material properties is often missing. Additional complications arise due to different setups used for testing the materials, different cross-linking methods and different prestrains used in the actuators. Given the structure similarity of the polar component Px used in this work with the previously reported one,31 a comparison can be done regarding the incorporation of the polar phase into the matrix (i.e. interconnected networks versus blending). It seems that by chemically bonding the polar component to the nonpolar PDMS, materials with increased electromechanical stability are formed, in spite of the observed microphase separation. The high values obtained for the electrical breakdown recommend these materials as dielectrics in transducers applications.

The actuation strain in the thickness direction can be calculated according to eqn (1),47 where E is the electric field, ε0 = 8.854 × 10−12 F m−1 is the vacuum permittivity, ε′ and Y are permittivity and modulus of the sample:

 
image file: c5ra06865g-t1.tif(1)

Assuming incompressibility, it is also possible to estimate the lateral actuation strain (sx) according to eqn (2):

 
sx = (1 + sz)−0.5 − 1 (2)

The calculated and experimental results are shown in Fig. S10, for the lateral actuation strain at 30 V μm−1 and maximum actuation, respectively. A good correlation was obtained for both plots. With rising content of polar groups the maximum actuation strain elevates, which reflects the increase of the dielectric ε′. The exception is sample P62(1/3), for which both the calculated and the experimental values of sx are lower than expected, due to the lower breakdown in actuator.

Dielectric elastomers can also be used as generators to convert mechanical energy into electrical energy (operation known as energy harvesting or scavenging). For estimative calculation of the energy that could be generated, various models were proposed and different mechanisms of failure are considered.48 The evaluation of the energy conversion can be done using eqn (3) and assuming a series of approximations (see for example29,49). The specific energy per unit volume is a function of dielectric permittivity, breakdown field and maximum strain at break (smax).

 
image file: c5ra06865g-t2.tif(3)

Assuming Emax is the dielectric strength (EEB), the maximum energy difference calculated represents the theoretical maximum value that can be achieved. It is obvious that in practice lower voltages have to be applied, to avoid material failure. A more reasonable value for the Emax could be the Eb in actuator. Maximum strain at break is also a limit that involves material rupture and therefore calculations for an arbitrary 100% strain for all samples were also included, to allow comparison. The energy difference per volume unit gained during one working cycle, calculated using the Eb in actuation or the EEB and either smax or s = 100% are given in Table 6. The best values for the energy were obtained for P62(1/2), which has the highest ε′ and high breakdown field. There is a clear increase in energy gain for the materials containing polar groups and high breakdown field compared to the ones based on P0.

Table 6 The energy difference estimated with eqn (3) by using the dielectric permittivity at 10 kHz
Sample Energy differencea [mJ cm−3] Energy differenceb [mJ cm−3] Maximum energy differencec [mJ cm−3]
a Calculated with Emax = Eb in actuation and smax at break.b Calculated with Emax = Eb in actuation and smax = 100%.c Calculated with Emax = EEB and smax at break.
P89(1/2) 7.0 5.9 16.3
P89(1/3) 10.5 8.7 19.5
P62(1/2) 53.9 46.9 64.0
P62(1/3) 18.3 15.4 53.3
P10(1/2) 41.1 34.7 43.9
P10(1/3) 26.2 21.3 59.9
P0(1/2) 12.3 10.4 31.0
P0(1/3) 9.6 8.0 38.6
P62part(1/2) 15.3 12.5 66.0
softP62(1/3) 24.0 18.9 66.7
softP62part(1/2) 36.4 28.1 52.0
PDMS 23.4 20.7 159.4


The silicone film from PolyPower™ was investigated regarding the energy scavenging.50 The modeled and experimental energy generated per cycle by an element having a roughly estimated volume of ca. 3 cm3 at a maximum strain of 15% and 1800 V was ca. 94 mJ. The calculated energy would place our materials within the range of promising materials for energy harvesting. Since this is just a rough estimation of the harvesting potential, further work is needed to measure experimentally the energy gained.

Optimized materials

As discussed above, the silicone matrix used was rather stiff (see Table 4). It is therefore possible to further optimize the mechanical properties by using a PDMS of a higher Mw or by lowering the amount of TEOS used. Preliminary results show that much softer materials with higher strains at break can be prepared (see ESI). For example, when the amount of TEOS was reduced from ca. 50 down to 20% reported to the mass of polymers (material softP62(1/3)), the mechanical properties were significantly improved: the strain at break was increased to 350% and the Young's modulus at 10% strain was only 0.275 MPa (Table S1).

When preformed polar particles were dispersed in a PDMS of a Mw = 400 kDa, an even softer material was obtained (softP62part(1/2)), with elongation at break as high as 489%, tensile strength of ca. 0.6 MPa and Young's modulus as low as 0.14 MPa.

The electromechanical performance of these materials was improved. For example, the maximum actuation strain almost doubled for softP62(1/3) compared to P62(1/3) (6.3% versus 3.2%). The estimated harvesting performance of softP62(1/3) is also better than its corresponding reference (Table 6). For the blends with polar particles, the actuation strain at 30 V μm−1 was similar, while the maximum actuation strain was double when 400 kDa PDMS was used as the matrix (Fig. S11).

Conclusions

Polysiloxanes Px with varying mol% of polar cyano groups were used as high permittivity components in a high molecular weight PDMS matrix. Incorporation of a large amount of polar Px was possible by using either a three-step process that allows formation of interconnected networks or by using readily dispersible polar nanoparticles. By using these approaches the macroscopic phase separation was avoided and materials with increased permittivity and good mechanical properties formed. Additionally, the dielectric breakdown of these materials was significantly higher as compared to similar reported materials prepared by blending a polar filler into nonpolar PDMS matrix. Furthermore, materials with up to 13-times higher actuation strain as compared to the silicone matrix were obtained. The actuation strain can be easily tuned by using different amount and type of Px. Theoretical calculations predict that these materials might be suitable for energy harvesting.

Acknowledgements

We gratefully acknowledge the financial support of Swiss National Science Foundation and UEFISCDI, under the Swiss-Romanian Cooperation Program, grant no. IZERZO_142215/1 (10/RO-CH/RSRP/01.01.2013) and SNFS, grant no. 150638, COST Action MP1003, and Swiss Federal Laboratories for Materials Science and Technology (Empa, Dübendorf). One of the authors (C.-D.V.) acknowledges the financial support of a grant of the Romanian National Authority for Scientific Research, project number PN-II-ID-PCCE-2011-2-0028. We also acknowledge Dr Rentsch for his kind support with the NMR investigations.

References

  1. T. Mirfakhrai, J. D. W. Madden and R. H. Baughman, Mater. Today, 2007, 10, 30–38 CrossRef CAS.
  2. Y. Bar-Cohen, Electroactive Polymer (EAP) Actuators as Artificial Muscles—Reality, Potential and Challenges, SPIE - Optical Engineering Press, Bellingham, WA, 2001 Search PubMed.
  3. S. G. Wax and R. R. Sands, Proc. SPIE, 1999, 3669, 2–10 CrossRef CAS PubMed.
  4. J. Eckerle, S. E. Stanford, J. P. Marlow, R. Schmidt, S. Oh, T. P. Low and S. V. Shastri, Proc. SPIE, 2001, 4332, 269–280 CrossRef PubMed.
  5. R. Pelrine, R. Kornbluh, Q. Pei, S. Stanford, S. Oh, J. Eckerle, R. Full, M. Rosenthal and K. Meijer, Proc. SPIE, 2002, 4695, 126–137 CrossRef CAS PubMed.
  6. Q. Pei, M. Rosenthal, R. E. Pelrine, S. E. Stanford and R. D. Kornbluh, Proc. SPIE, 2003, 5051, 281–290 CrossRef PubMed.
  7. S. Ashley, Sci. Am., 2003, 289, 52–59 CrossRef CAS.
  8. R. Kornbluh, R. Pelrine, Q. Pei, and V. Shastri, in Artificial Muscles Reality, Potential and Challenges, ed. Y. Bar-Cohen, SPIE Press, Bellingham, Washington, DC, 2001, ch. 16, pp. 457–503 Search PubMed.
  9. H. Herr and R. Kornbluh, Smart Structures and Materials: Electroactive Polymer Actuators and Devices, San Diego, CA, 2004 Search PubMed.
  10. M. Palmer, Department of Mechanical Engineering, M.S. thesis, MIT, Boston, MA, 2002.
  11. L. L. Creswell, M. Rosenbloom, J. L. Cox, T. B. Ferguson, N. T. Kouchoukos, T. L. Spray, M. K. Pasque, T. B. Ferguson, T. H. Wareing and C. B. Huddleston, Ann. Thorac. Surg, 1992, 54, 11–18 CrossRef CAS.
  12. F. D. Pagani, K. D. Aaronson, D. B. Dyke, S. Wright, F. Swaniker and R. H. Bartlett, Ann. Thorac. Surg, 2000, 70, 1977–1985 CrossRef CAS.
  13. F. Carpi, and D. de Rossi, Proceedings of the Electroactive Polymer Actuators and Devices (EAPAD), San Diego, CA, 2007, p. 65240D Search PubMed.
  14. C. Menon, F. Carpi and D. de Rossi, Acta Astronaut., 2009, 4329, 825–833 CrossRef PubMed.
  15. R. D. Kornbluh, D. S. Flamm, H. Prahlad, K. M. Nashold, S. Chhokar, R. Pelrine, D. L. Huestis, J. Simons, T. Cooper and D. G. Watters, Proc. SPIE, 2003, 5051, 143–158 CrossRef PubMed.
  16. G. J. Lin, X. B. Zhang and D. C. Song, Adv. Mater. Res., 2011, 328–330, 1491–1494 CrossRef CAS.
  17. R. Yang, Y. Qin, C. Li, G. Zhu and Z. L. Wang, Nano Lett., 2009, 9, 1201–1205 CrossRef CAS PubMed.
  18. P. Harsha, R. Kornbluh, R. Pelrine, S. Stanford, J. Eckerle and S. Oh, Proc of Int. Conf. on Smart Materials Structures and Systems, Bangalore, 2005 Search PubMed.
  19. S. Chiba, M. Waki, R. Kormbluh and R. Pelrine, Proc. SPIE, 2008, 6927, 1–9 CrossRef PubMed.
  20. R. Vertechy, M. Fontana, G. P. Rosati Papini and M. Bergamasco, Proc. SPIE, 2013, 8687,  DOI:10.1117/12.2012016.
  21. J. Maas and C. Graf, Smart Mater. Struct., 2012, 21, 064006 CrossRef.
  22. B. Kussmaul, S. Risse, M. Wegener, M. Bluemke, J. Krause, J. Wagner, T. Feller, K. Clauberg, J. Hitzbleck, R. Gerhard and H. Krueger, Electroactive Polymer Actuators and Devices (EAPAD), 86872S, Proc. SPIE, 2013, 8687,  DOI:10.1117/12.2009102.
  23. R. Kornbluh and R. Pelrine, High-performance acrylic and silicone elastomers, in Dielectric elastomers as electromechanical transducers, ed. F. Carpi, D. De Rossi, R. Kornbluh, R. Pelrine and P. Sommer-Larsen, Elsevier, Pisa, 2007 Search PubMed.
  24. M. G. Voronkov, V. P. Mileshkevich and Y. A. Yuzhelevskii, The Siloxane Bond: Physical Properties and Chemical Transformations, Consultants Bureau, New York, 1978 Search PubMed.
  25. Silicon-Containing Polymers: The Science and Technology of Their Synthesis and Applications, ed. R. G. Jones, W. Ando and J. Chojnowski, Kluwer Academic Publishers, Dordrecht, The Netherlands, 2000 Search PubMed.
  26. W. Noll, Chemistry and Technology of Silicones, Academic Press, New York and London, 1968 Search PubMed.
  27. A. C. M. Kuo, Poly(dimethylsiloxane), in Polymer Data Handbook, Oxford University Press, 1999, pp. 411–435 Search PubMed.
  28. A. P. Mulgaonkar, R. Kornbluh and H. Herr, Biomedical, Haptic and Micro-Scale Applications, in Dielectric elestomers as electromechanical transducers, ed. F. Carpi, D. De Rossi, R. Kornbluh, R. Pelrine and P. Sommer-Larsen, Elsevier, Pisa, 2007 Search PubMed.
  29. M. Molberg, D. Crespy, P. Rupper, F. Nüesch, J. A. E. Månson, C. Löwe and D. M. Opris, Adv. Funct. Mater., 2010, 20, 3280–3291 CrossRef CAS PubMed.
  30. F. B. Madsen, L. Yu, A. E. Daugaard, S. Hvilsted and A. L. Skov, Polymer, 2014, 55, 6212–6219 CrossRef CAS PubMed.
  31. S. Risse, B. Kussmaul, H. Krüger and G. Kofod, Adv. Funct. Mater., 2012, 22, 3958–3962 CrossRef CAS PubMed.
  32. F. B. Madsen, I. Dimitrov, A. Daugaard, S. Hvilsted and A. L. Skov, Polym. Chem., 2013, 4, 1700–1707 RSC.
  33. S. Dünki, Y. S. Ko, F. A. Nüesch and D. M. Opris, Adv. Funct. Mater., 2015, 25, 2467 CrossRef PubMed; S. J. Dünki, M. Tress, F. Kremer, S. Y. Ko, F. A. Nüesch, C.-D. Varganici, C. Racles and D. M. Opris, RSC Adv., 2015, 5, 50054 RSC.
  34. C. Racles, M. Cazacu, B. Fischer and D. M. Opris, Smart Mater. Struct., 2013, 22, 104004 CrossRef.
  35. C. Racles, M. Alexandru, A. Bele, V. E. Musteata, M. Cazacu and D. M. Opris, RSC Adv., 2014, 4, 37620–37628 RSC.
  36. C. Racles, Soft Mater., 2010, 8, 1–11 CrossRef PubMed.
  37. M. Kollosche and G. Kofod, Appl. Phys. Lett., 2010, 96, 071904 CrossRef PubMed.
  38. A. L. Smith, Analysis of silicones in Chemical Analysis, A series of monographs on analytical chemistry and its applications, ed. A. L. Smith, Wiley, USA, 1974, vol. 41 Search PubMed.
  39. I. Yilgor and J. E. McGrath, Adv. Polym. Sci., 1988, 86, 1–86 CrossRef CAS.
  40. C. Racles, A. Ioanid, A. Tóth, M. Cazacu and V. Cozan, Polymer, 2004, 45, 4275–4283 CrossRef CAS PubMed.
  41. C. D. Varganici, O. Ursache, C. Gaina, V. Gaina and B. C. Simionescu, J. Therm. Anal. Calorim., 2013, 111, 1561–1570 CrossRef CAS.
  42. C. D. Varganici, L. Rosu, D. Rosu and B. C. Simionescu, Composites, Part B, 2013, 50, 273–278 CrossRef CAS PubMed.
  43. P. R. Sundarajan, Polymer, 2002, 43, 1691–1693 CrossRef.
  44. M. Alexandru, M. Cristea, M. Cazacu, A. Ioanid and B. C. Simionescu, Polym. Compos., 2009, 30, 751–759 CrossRef CAS PubMed.
  45. F. Carpi, G. Gallone, F. Galantini and D. De Rossi, Adv. Funct. Mater., 2008, 18, 235–241 CrossRef CAS PubMed.
  46. A. K. Jonscher, J. Phys. D: Appl. Phys., 1999, 32, R57–R70 CrossRef CAS.
  47. R. E. Pelrine, R. D. Kornbluh and J. P. Joseph, Sens. Actuators, A, 1998, 64, 77–85 CrossRef CAS.
  48. S. J. A. Koh, C. Keplinger, T. Li, S. Bauer and Z. Suo, IEEE/ASME Trans. Mechatron., 2011, 16, 33–41 CrossRef.
  49. S. J. A. Koh, X. Zhao and Z. Suo, Appl. Phys. Lett., 2009, 94, 262902 CrossRef PubMed.
  50. Y. H. Iskandarani, R. W. Jones and E. Villumsen, Proc. SPIE, 2009, 7287, 72871Y,  DOI:10.1117/12.815267.

Footnote

Electronic supplementary information (ESI) available: 29Si and 1H NMR spectra, FT-IR spectra, images of the films, SEM image of a blend with Px particles, DSC curves, DMA, fatigue resistance tests, calculated actuation, mechanical and electromechanical properties of the optimized materials. See DOI: 10.1039/c5ra06865g

This journal is © The Royal Society of Chemistry 2015
Click here to see how this site uses Cookies. View our privacy policy here.