Denghao
Zhu†
*a,
Leopold
Seifert
a,
Sumit
Agarwal
a,
Bo
Shu
a,
Ravi
Fernandes
ab and
Zhechao
Qu
*a
aDepartment of Physical Chemistry, Physikalisch-Technische Bundesanstalt, Braunschweig, Germany. E-mail: denghao.zhu@seu.edu.cn; zhechao.qu@ptb.de
bInstitute of Internal Combustion Engines, Technische Universität Braunschweig, Braunschweig, Germany
First published on 18th March 2025
Two laser absorption spectroscopy (LAS)-based spectrometers have been developed for measuring carbon monoxide (CO) pressure broadening and temperature dependency coefficients in the 1 ← 0 band. Using a scanned-wavelength LAS at 140 Hz, pressure broadening coefficients of four CO transition lines P(16), P(20), P(26), and P(27), perturbed by Ar, He, H2, O2, N2, CO2, and Air have been systematically measured in a gas cell using a consistent metrological approach. Results indicate that the CO pressure broadening coefficient decreases monotonically as the line number |m| increases. The variation of pressure broadening coefficients at different buffer gases follow a consistent trend for all four measured lines: CO–H2 and CO–Ar show the highest and lowest pressure broadening coefficients, respectively. Compared to the literature results with relatively large uncertainties or even unavaible uncertainty information, the uncertainty of measured pressure broadening coefficients is below 1% for most cases. Further, using a scanned-wavelength LAS at 20 kHz, temperature dependence coefficients of P(20) in Ar, He, N2 and CO2 were measured at a temperature range of 430–1648 K in a shock tube. With this rapid scan frequency, the spectrum between incident shock and reflected shock was also used for temperature dependence coefficient calculation. The uncertainty of the measured temperature dependence coefficients are under 6.2%. Toward combustion systems as an application case, the CO mole fraction during CH4 oxidation in the shock tube was quantified using a fixed-wavelength LAS. The results reveal that the uncertainty in CO mole fraction was reduced by a factor of 2.7 when using the line parameters obtained in this study compared to those from the HITRAN database. Thus, the newly measured data with low uncertainties substantially enhance the spectroscopic database, enabling more precise CO mole fraction quantification across a range of application scenarios such as environmental monitoring, industrial control, safety monitoring, medicine, astronomy, and scientific research.
Concerning such broad application scenarios, accurate quantification of CO mole fraction becomes vital.
Laser absorption spectroscopy (LAS) is an advanced in situ, non-invasive, and highly selective optical diagnostic technique that has been extensively developed and widely utilized for precise molecule fingerprint detection in various scientific and industrial applications. Several specific spectroscopic sensing techniques fall under the umbrella of LAS, each with its own advantages and applications. Direct absorption spectroscopy (DAS) is the most straightforward approach, where the attenuation of laser light due to molecular absorption is directly measured to determine species concentration and temperature. Wavelength modulation spectroscopy (WMS) enhances sensitivity by modulating the laser wavelength and detecting absorption signals at higher harmonics, making it particularly effective for low-concentration measurements in noisy environments. Off-axis integrated cavity output spectroscopy (OA-ICOS) combines the principles of cavity-enhanced spectroscopy with off-axis alignment to achieve highly sensitive and precise measurements of gas-phase species. The dual-comb spectroscopy technique leverages the interference of two frequency combs to achieve ultra-high spectral resolution and rapid data acquisition, enabling the simultaneous detection of multiple species with exceptional precision. Photoacoustic spectroscopy (PAS), on the other hand, detects acoustic waves generated by the absorption of modulated laser light, offering high sensitivity and suitability for trace gas analysis. These techniques have been extensively validated and applied in a wide range of fields, as evidenced by numerous studies.13–17
To implement LAS, accurate spectroscopic parameters are the premise. CO has a strong characteristic absorption band in the infrared (IR) region. The most prominent IR band of CO is centered around 4.7 μm, corresponding to the transition from the ground vibrational state (v = 0) to the first excited vibrational state (v = 1). The first overtone band of CO (Δv = 2) is near 2.3 μm and the second overtone band (Δv = 3) is near 1.55 μm. The line intensity of the fundamental band is approximately 10000 and 100 times stronger compared to the overtone bands near 1.55 μm and 2.3 μm, respectively.18 Besides, the fundamental band has relatively weaker interference from common species, making it more promising for sensitive detection.
For decades, spectroscopic parameters of CO in the 1 ← 0 band have been extensively studied.19–31 With the development of optical techniques and molecule spectroscopy theory, the quantity and accuracy of the spectroscopic data are continuously improving. Nevertheless, there are still some spaces that need to be improved. Firstly, most pressure broadening coefficients were measured using air as the buffer gas. For example, in the HITRAN database,32 broadening parameters due to pressure of “planetary” (H2, CO2, He) gases were only introduced in 2016 and most data were generated from extrapolating very limited experimental data. Broadening parameters in other buffer gases are scarce. In some specific applications, such as combustion study, Ar, He and N2 are commonly used buffer gases. The relevant spectroscopic data becomes vital. Therefore, systematic spectroscopic parameters at a variety of buffer gases are required. Secondly, most studies report the line parameters of CO with a line number |m| below 25. However, at elevated temperatures, higher rotational levels will be significantly populated. To complement the entire database, more efforts should be made to the absorption lines with higher |m|. Thirdly, compared to pressure broadening coefficients, there is much less data available for temperature dependence coefficients. One of the main reasons is a higher requirement for experimental facilities. Fourier-transform infrared spectroscopy (FTIR) is the most used, and the working temperature is generally below 296 K. Using a heated cell can target higher temperatures but typically below 1000 K. To achieve even higher temperatures, a shock tube is considered an ideal reactor that can create a quasi-instantaneously and homogeneously high temperature and pressure environment with a time scale of microseconds or milliseconds. Most spectroscopic measurements for combustion or space exploration studies were done in a shock tube. For example, for line P(20) investigated in this study, Ren et al.,18 Spearrin et al.33 and Grégoire et al.34 measured temperature dependence coefficients in a shock tube.
In this study, the focus is to measure the pressure broadening and temperature dependence coefficients of four specific CO transitions near 4.9 μm: P(16), P(20), P(26), and P(27). Two in-house spectrometers have been built accordingly. Specifically, a scanned-wavelength LAS operating at 140 Hz was used to measure the pressure broadening coefficients of those four CO transition lines perturbed by Ar, He, H2, O2, N2, CO2, and air in a gas cell. Then, the temperature dependence coefficients of P(20) in Ar, He, N2 and CO2 were measured in a shock tube using a scanned-wavelength LAS at 20 kHz. This much faster scan frequency compared to pressure broadening measurements is to match the short timescale of shock tube processes. As an application case, the time-resolved CO mole fraction during CH4 oxidation in the shock tube was measured using a fixed-wavelength LAS. The uncertainty of CO mole fraction has been metrologically analysed and compared based on the line parameters measured in this study and from HITRAN.
It(υ) = E(t) + I0(υ)·η(t)·exp[−α(v)] | (1) |
![]() | (2) |
The Voigt function can be used to model the line shape of the absorbance spectrum in eqn (2), which considers the combined effects of Doppler and collisional broadening on the spectral line. These effects are characterized by the Doppler broadening full width at half maximum (FWHM), ΔvD, and the collisional-broadening FWHM, ΔvL, given by
![]() | (3) |
![]() | (4) |
![]() | (5) |
The temperature dependence coefficient can be obtained from the slope of the linear regression between and
.
For temperature dependence coefficient measurement, a shock tube was used. A detailed description of the shock tube can be found in our previous paper,35–37 so only a brief introduction is given here. The shock tube consists of a 3.5-meter driver section and a 4.5-meter driven section with an overall inner diameter of 7 cm. Five pressure sensors (603CAB, Kistler) were utilized for pressure measurements. The initial pressure (P1) of the mixture charged into the driven section was measured by a pressure sensor (MKS Baratron, 0–1000 mbar). The pressure (P2) and temperature (T2) after the incident shock wave and the pressure (P5) and temperature (T5) after the reflected shock wave were calculated using the one-dimensional shock equations. For this study, only the temperature dependence coefficient of P(20) was measured which has been proven to be well suited for combustion-related study.18
Fig. 1(b) shows the established spectrometer for temperature dependence coefficient measurement by coupling LAS to the shock tube. As the time scale in the shock tube is in micro to milliseconds, the scan frequency of the laser was enhanced to 20 kHz for dynamic measurements. The laser beam was focused using a concave mirror (CM508-200-M01, 200 mm focal length, Thorlabs) and passed through optical windows positioned in the same plane as the fourth pressure sensor, with an optical path length of 7 cm. A separate laser branch was directed to the etalon and the signal was recorded prior to the measurements. After passing the gases, the laser was focused onto a photodetector (PVI-4TE-5, VIGO) by a concave mirror (CM508-050-M01, focal length: 50 mm, Thorlabs). A narrow bandpass filter (CWL = 4856 nm, BW = 30 nm, laser components) was placed in front of the detector to separate the signal from the background emission E(t) in eqn (1), e.g., thermal emission from the shock-heated gases. The pressure and photodetector signals were recorded by a 16-bit 80 MS s−1 data acquisition card (M2p.5943-x4, Spectrum Instrumentation).
To derive the foreign broadening coefficients, a high-quality pure CO (purity 5.0, Linde) was utilized. The procedure employed for gas mixture preparation is as follows: (1) evacuate the whole system including gas cell and all components in the gas manifold up to the gas cylinder; (2) flush the gas cell with pure CO and then evacuate the system; (3) repeat step 2 for three times; (4) keep pure CO in cell with a pressure below 0.5 mbar; (5) fill the buffer gas to a certain pressure and start the measurement over minutes; (6) partially evacuate the mixture to another certain pressure and record the data; (7) repeat step 6 at different pressures and buffer gases (Ar, He, H2, O2, N2, CO2 and air). The gas pressure in the cell was regulated by the gas cell outlet valve and the exhaust pump.
Fig. 3 shows an exemplary raw laser signal and an etalon signal in a half period, where a clearly isolated CO absorption peak can be observed. From the etalon signal, there is a non-uniform distribution of the peak's interval, indicating the non-linear behavior of the laser during the current modulation. The free spectral range (FSR) is calculated to be 0.01633 cm−1 at the center wavelength of 2059.91 cm−1 with a refractive index of 4.0167. With this information, it can convert the raw laser signal from the time-domain to frequency-domain.
Because of a consistent procedure being used for different CO transitions as well as different buffer gases, only CO–H2 broadening coefficient of P(20) line is illustrated as an example. Firstly, the measured laser signal was averaged over ten scans and fitted with a third-order polynomial for the baseline. It was converted to absorbance using Beer–Lambert raw according to eqn (1) and (2), as shown in Fig. 4(a). The absorption profile was fitted by the Voigt profile using a non-linear Levenberg–Marquart algorithm. The residual between measured and fitted data shown below in Fig. 4(a) is (1σ) 1.51 × 10−3 optical density. To clearly discriminate the pressure-broadening effect, the Gaussian width was calculated using the measured gas temperature according to eqn (3). The line width progression at different pressures was used to extract the pressure broadening coefficient. A weighted linear fit method (York Fit) was used to consider both the uncertainties from x and y axis. The pressure measurements were associated with 0.1–0.5% uncertainty (k = 1) according to PTB's pressure standard, of which the uncertainty has been considered for the linear regression as the x-error bar. The standard deviation (1σ) of the line width results (more than 200 measurements) at each pressure step, together with the wavenumber scale (laser tuning) uncertainty, was used as the y-error bar. Fig. 4(b) illustrates the linear regression between the Lorentzian FWHM and the pressure of CO–H2, demonstrating excellent linearity. The residuals between measured data and linear fit are within 8 × 10−4 cm−1 range. The slope of the linear fit divided by 2 is the CO–H2 broadening coefficient which is 0.06975 cm−1 per atm with an uncertainty of 0.0005 cm−1 per atm.
![]() | ||
Fig. 4 (a) CO absorption spectrum of P(20) in H2; (b) CO–H2 pressure broadening of P(20) (the x and y axis error bars are hidden within the symbol). |
Following the same methodology, the pressure broadening coefficients at different buffer gases and for different CO transitions have been consistently measured and are shown in Fig. 5. From the results of the literature, the pressure broadening coefficient of CO monotonically decreases with the increase of line number |m|.30 Our measured results also follow this tendency, namely pressure broadening coefficients decrease from P(16) (m = −16) to P(27) (m = −27). The variations of pressure broadening coefficients at different buffer gases are also well-aligned for four lines, e.g. the CO–H2 and CO–Ar show the highest and lowest pressure broadening coefficients, respectively.
![]() | ||
Fig. 5 (a) Pressure broadening coefficients versus line numbers; (b) pressure broadening coefficients versus buffer gases (the error bars are hidden within the symbol). |
For those four specific CO absorption lines, some data is available in the literature and in the HITRAN database. Fig. 6 shows the comparison of pressure broadening coefficients between this study and the literature results. As mentioned in the Introduction part, most studies only report the results with |m| below 25. Fig. 6 shows some literature data for P(16) and P(20) but very rare data for P(26) and P(27). Overall, our measured data align well with the literature results regarding the variation tendency of different buffer gases. The values are also aligned with some of the literature values and most values from HITRAN database. It is worth mentioning that for P(20), Crane-Robinson and Thompson19 measured the pressure broadening over a variety of buffer gases, including Ar, He, H2, O2, N2 and CO2, using a grating spectrometer with a resolution of 0.1 cm−1. Their results align well with the results of the literature and our measurements regarding the variation tendency, while the absolute values are lower overall and without uncertainty information (c.f. Table 1). This might be caused by the limited resolution and precision of the optical techniques at that time.
![]() | ||
Fig. 6 Comparison of pressure broadening coefficients with literature results (the error bars are hidden within the symbol). |
Ar | He | H2 | O2 | N2 | CO2 | Air | |
---|---|---|---|---|---|---|---|
The uncertainties are given in parentheses. | |||||||
P(16) | |||||||
1972, Bouanich and Haeusler20 | 0.04240 | ||||||
1980, Varghese and Hanson21 | 0.04250 | 0.06600 | |||||
1992, Thibault et al.22 | 0.04950 | ||||||
1998, Sinclair et al.23 | 0.04228 | 0.04647 | |||||
1999, Predoi-Cross et al.24 | 0.05447 | ||||||
2002, Zou and Varanasi25 | 0.05380 (61) | ||||||
2005, Régalia-Jarlot et al.27 | 0.06910 | 0.05430 | |||||
2016, Predoi-Cross et al.29 | 0.04658 | ||||||
2018, Devi et al.30 | 0.05419 (20) | ||||||
HITRAN32 | 0.04690 (469) | 0.06930 (693) | 0.06170 (617) | 0.05380 (538) | |||
This study | 0.04704 (61) | 0.04864 (38) | 0.08510 (61) | 0.05423 (41) | 0.05435 (65) | 0.06889 (58) | 0.05546 (59) |
P(20) | |||||||
1963, Crane-Robinson et al.19 | 0.03120 | 0.03950 | 0.05690 | 0.03870 | 0.04520 | 0.05130 | |
1972, Bouanich and Haeusler20 | 0.03950 | ||||||
1980, Varghese and Hanson21 | 0.04150 | 0.05400 | |||||
1998, Sinclair et al.23 | 0.03978 | 0.04605 | |||||
1999, Predoi-Cross et al.24 | 0.04615 | 0.05063 | |||||
2002, Zou and Varanasi25 | 0.05070 (79) | ||||||
2005, Régalia-Jarlot et al.27 | 0.06970 | 0.05060 | |||||
2005, Sung and Varanasi28 | 0.05610 (321) | ||||||
2012, Ren et al.18 | 0.03950 | ||||||
2023, Grégoire et al.34 | 0.04000 | 0.05300 | |||||
HITRAN32 | 0.04640 (464) | 0.06900 (69) | 0.05820 (582) | 0.05100 (510) | |||
This study | 0.03947 (20) | 0.04828 (32) | 0.06977 (52) | 0.04519 (6) | 0.05314 (31) | 0.05731 (32) | 0.05159 (32) |
P(26) | |||||||
1980, Varghese and Hanson21 | 0.05450 | ||||||
1998, Sinclair et al.23 | 0.03363 | ||||||
HITRAN32 | 0.04580 (458) | 0.06840 (684) | 0.05380 (538) | 0.04710 (471) | |||
This study | 0.03676 (38) | 0.04843 (52) | 0.06564 (108) | 0.03936 (46) | 0.04524 (32) | 0.05492 (42) | 0.04425 (63) |
P(27) | |||||||
1998, Sinclair et al.23 | 0.03379 | ||||||
HITRAN32 | 0.04570 (457) | 0.06840 (684) | 0.05310 (531) | 0.04650 (465) | |||
This study | 0.02973 (71) | 0.04235 (69) | 0.06288 (125) | 0.04087 (63) | 0.04401 (54) | 0.05099 (81) | 0.04203 (105) |
Table 1 summarizes the values of pressure broadening coefficients from the literature review and this study. Values in brackets denote uncertainties. As can be seen, none of the literature data provides systematic pressure broadening coefficient datasets of those four lines perturbed by those seven buffer gases (Ar, He, H2, O2, N2, CO2 and Air). Moreover, most literature results did not provide any information on uncertainties, or the uncertainties are much larger than the current study. For example, the uncertainties from HITRAN database are 5–10%, while in this study, most uncertainties are less than 1%. Hence, the consistent experimental data provided in this study are valuable for CO mole fraction quantification. On the other hand, for CO–Air pressure broadening coefficients, it is also feasible to estimate it by combining CO–O2 and CO–N2 broadening coefficients with a proportion of N2:
O2 = 79
:
21 based on the binary collision approximation. The calculated CO-Air pressure broadening coefficients of P(16), P(20), P(26) and P(27) are 0.05432 0.05147 0.04401 0.04335, respectively. They are close to the directly measured CO-air pressure broadening coefficients with a disparity of 2.06%, 0.23%, 0.54%, 3.14%, respectively, underscoring the reasonability of the measurements.
Fig. 7 shows the raw laser signal, etalon signal and pressure of 1% CO/1% H2/98% Ar mixture measured in the shock tube. The pressure was measured by the fourth sensor, which is located on the same plane as the laser. In the pressure profile, two sharp pressure rises can be distinguished, indicating the arrival of incident shock and reflected shock, respectively. For this case, the initial pressure (P1) of the mixture is 0.04 bar. Then, the mixture was heated to 837 K and 0.31 bar by the incident shock wave and again heated to 1543 K and 1.20 bar by the reflected shock wave within 80 μs. Because of a highly diluted mixture being used, the pressure drop is negligible within a certain period.
For the laser signal, the line shape significantly changes during the shock propagation. When the incident and reflected shock pass through the optical window, two interferences can be observed in the laser signal caused by the Schlieren effect. Notably, in the previous literature work,18,34 the scan frequency was limited to 2.5 kHz, and therefore only the spectrum at (T5, P5) was used. With the rapid scan frequency of 20 kHz used in this study, the spectrum at (T2, P2) was also used for the first time. This novel idea fulfils the feature of a shock tube that can get double information of two temperature and pressure combinations within a single shot. Based on that, the temperature range covers from 430–1648 K and pressure ranges from 0.17–2.23 bar. On top of Fig. 7 is the measured etalon signal at 20 kHz to convert the laser signal from time-domain to frequency-domain.
The raw laser signal in a half period was extracted and fitted with a third-order polynomial for the baseline. Then the CO absorption profile can be obtained according to eqn (1) and (2). Fig. 8 shows the fitted baseline (reference signal), CO laser signals and absorbances at three stages during the shock propagation, where the effect of both pressure and temperature on the line shape can be clearly observed. For example, the absorption profile is significantly broadened at P5 compared to P1 and P2. The absorbance at T2 is the highest, which is reasonable according to the line intensity variation against the temperature of P(20), as shown in Fig. 10.
Further, the CO absorption spectrum was fitted by the Voigt profile using a non-linear Levenberg–Marquart algorithm, as shown in Fig. 9(a). Here the CO absorption profile at (T5, P5) is taken as an example. The residual between measured and fitted data is (1σ) 7.1 × 10−3 optical density. According to eqn (5), the line width progression at different temperatures was used to extract the temperature dependence coefficient. According to our previous study,37 the uncertainties of T2, T5, P2 and P5 are 1.35%, 1.8%, 2% and 2.8% (k = 1), respectively. Those uncertainties have been considered as the x and y-error bar for linear regression. Fig. 9(b) shows the linear regression for CO–Ar temperature dependence. The slope of the linear fit is the CO–Ar temperature dependence coefficient which is 0.60484 with an uncertainty of 0.03701. As mentioned above, 1% H2 has been added to the mixture considering the vibrational relaxation effect. We have also measured 1% CO/99% Ar mixture as a comparison. The temperature dependence coefficient of 1% CO/99% Ar mixture is 0.595, which is very close to that of 1% CO/1% H2/98% Ar mixture. The detailed discussion on this part has beyond the scope of the current study, while the effect of vibrational relaxation on temperature dependence coefficients merit further investigations in the future.
![]() | ||
Fig. 9 (a) CO absorption spectra in 1% CO/1% H2/98% Ar; (b) temperature dependence coefficient of CO–Ar. |
Using the same method, temperature dependence coefficient of CO–He, CO–N2 and CO–CO2 of P(20) have been measured. Fig. 11 compares measured temperature dependency coefficients with results from the literature. The values are summarized in Table 2, of which the values in brackets denote uncertainties. From Fig. 11, the current results align with most literature results when taking uncertainties into account. This study is the first time to systematically measure the CO–Ar, CO–He, CO–N2 and CO–CO2 temperature dependence coefficient of P(20), with uncertainties (<6.2%) information being given.
P(20) | Ar | He | N2 | CO2 |
---|---|---|---|---|
The uncertainties are given in parentheses. | ||||
1999, Predoi-Cross et al.24 | 0.643 | |||
2005, Mantz et al.26 | 0.558 | |||
2012, Ren et al.18 | 0.639 (24) | |||
2014, Spearrin et al.33 | 0.550 (17) | |||
2016, Predoi-Cross et al.29 | 0.563 | |||
2023, Grégoire et al.34 | 0.618 (48) | 0.983 (25) | ||
HITRAN32 | 0.550 (11) | 0.700 (14) | ||
This study | 0.605 (37) | 0.478 (25) | 0.649 (28) | 0.649 (30) |
To comprehensively evaluate the line parameters, we prepared a mixture of 3.3% CH4/6.7% O2/20% He/70% Ar including both buffer gases of He and Ar. Also, 20% He can effectively and sufficiently suppress the vibrational relaxation problem of CO without perturbating the chemical process. To achieve a high time resolution, a fixed-wavelength LAS was used by tunning the P(20) laser at its central wavelength of 2059.91 cm−1.
According to the ‘Guide to the expression of uncertainty in measurement (GUM)’, the combined standard uncertainty u(x) is the positive squared root of the combined variance which is given by:38
![]() | (6) |
For the uncertainty of CO mole fraction, the correlations between mole fraction x and related quantities Yi can be expressed through a functional relationship:
x = f(α(v), L, p, T, v0, S, γ, n) | (7) |
For CO mole fraction calculation using line parameters from HITRAN, there are no data on CO–Ar pressure broadening coefficient (γCO–Ar) and temperature dependence coefficient (nCO–Ar) available in the HITRAN database. Therefore, the value of CO–air pressure broadening coefficient (γCO–air) and temperature dependence coefficient (nCO–air) in HITRAN was adopted as replacements and assigned an uncertainty of 20%. Another clarification is the pressure broadening and temperature dependence of the other 10% gases (except 20% He and 70% Ar) which are dynamically changing during the oxidation. This point has been discussed in our previous work39 and is beyond the scope of this study. Here we simplified to assign γCO-rest with a fixed value adopting from γCO–air measured in this study and assign nCO-rest with a default value of 0.5. Both γCO-rest and nCO-rest are assigned with an uncertainty of 20%.
Fig. 12 shows the time-resolved CO mole fraction during the CH4 oxidation in the shock tube using the pressure broadening coefficients and temperature dependence coefficients measured in this study (red line) and HITRAN database (blue line). On one hand, the difference between both calculated CO mole fractions is relatively small. But it should be careful that the CO profile using line parameters from HITRAN is an ‘unreal’ value as γCO–Ar and nCO–Ar are missing and were manually assigned. On the other hand, what matters most is the uncertainty of CO mole fraction indicated by the shadows, which are 2.7 times difference.
![]() | ||
Fig. 12 Time-resolved CO mole fraction of CH4 oxidation measured in the shock tube and calculated using NUIG 1.3 mechanism.40 |
As mentioned above, since the HITRAN database does not provide spectroscopy data for Ar and has much higher uncertainties in spectroscopy data for He, it results in significant uncertainty in the overall concentration calculation as emphasized in the uncertainty budget in Table 3. Thus, this case study has strongly proved the importance of accurate line parameters in reducing the uncertainty of CO mole fraction quantification. Furthermore, we performed kinetic modelling to simulate the CO profile using NUIG 1.3 mechanism,40 as shown in Fig. 12. The simulated CO mole fraction is within the 21.7% uncertainty range based on HITRAN database, but it is already beyond the range of 8% uncertainty based on the spectroscopy parameters measured in this study. This result indicates that low uncertainty data can provide guidance on the refinement of chemical kinetics models.
Quantity | This study | HITRAN32 | ||||
---|---|---|---|---|---|---|
Value | Uncer (%) | Index (%) | Value | Uncer (%) | Index (%) | |
α(v) | 0.7 | 0.7 | 0.76 | 0.7 | 0.7 | 0.1 |
L | 7 cm | 1.1 | 1.87 | 7 cm | 1.1 | 0.26 |
p | 1.7 bar | 1.5 | 0.06 | 1.7 bar | 1.5 | 0.008 |
T | 2700 K | 2.2 | 38.4 | 2700 K | 2.2 | 5 |
v 0 | 2059.91 cm−1 | 0.0001 | 2.87 × 10−9 | 2059.91 cm−1 | 0.0001 | 4.01 × 10−10 |
S(T0) | 3.535 × 10−20 cm per molecule | 2.5 | 9.67 | 3.535 × 10−20 cm per molecule | 2.5 | 1.33 |
γ CO–Ar | 0.03947 cm−1 per atm | 0.51 | 0.1 | 0.051 cm−1 per atm | 20 | 26.98 |
γ CO–He | 0.04828 cm−1 per atm | 0.66 | 0.038 | 0.0464 cm−1 per atm | 10 | 0.77 |
γ CO-rest | 0.05159 cm−1 per atm | 20 | 8.79 | 0.05159 cm−1 per atm | 20 | 1.17 |
n CO–Ar | 0.60484 | 6.12 | 26.95 | 0.67 | 20 | 58.43 |
n CO–He | 0.47844 | 5.15 | 2.57 | 0.55 | 20 | 4.52 |
n CO-rest | 0.5 | 20 | 10.74 | 0.5 | 20 | 1.43 |
x CO | 0.0267 | 8.0 | 0.0272 | 21.7 |
For pressure broadening coefficient measurements, one ICL laser centered at 4855 nm was used to study P(20) and another ICL laser centered at 4925 nm was used to study P(27), P(16) and P(26). Both lasers were coupled to a single gas cell. For the first time, pressure broadening coefficients of P(20), P(27), P(16) and P(26) perturbed by Ar, He, H2, O2, N2, CO2, and air were consistently measured and reported. The pressure broadening coefficient monotonically decreases with the increase of line number |m|, namely pressure broadening coefficients decrease from P(16) (m = −16) to P(27) (m = −27). This tendency is consistent with the literature results. The variation of pressure broadening coefficients at different buffer gases are consistent for all four lines, e.g. the CO–H2 and CO–Ar show the highest and lowest pressure broadening coefficients, respectively. The measured pressure broadening coefficients align with most literature results, but the uncertainties in the current study are significantly lower. For most results, the uncertainty is below 1%.
Secondly, the P(20) laser was coupled into a shock tube for temperature dependence coefficient measurements. With a rapid scan frequency of 20 kHz, for the first time, the spectra between incident shock and reflected shock were also used for temperature dependence coefficient calculations. The novelty is to get more information at two different temperature and pressure combinations within a single shot. On that basis, CO–Ar, CO–He, CO–N2 and CO–CO2 temperature dependence coefficients of P(20) were measured with uncertainties below 6.2%. The results are consistent with most literature results.
As a case study, CH4 oxidation experiments were conducted in the shock tube using a fixed-wavelength LAS for high time resolution. This application case shows the feasibility of using measured line parameters to quantify time-resolved CO profiles. Moreover, the metrological uncertainty analysis reveals that the uncertainty of CO mole fraction can be reduced by a factor of 2.7 using the line parameters measured in this study compared to those from the HITRAN database. Overall, the newly collected data, with minimal uncertainties, greatly improve the spectroscopic database, allowing for more accurate quantification of CO mole fractions in diverse application scenarios.
For future work, we intend to measure temperature dependence coefficients in a heated cell which provides more stable temperature and pressure conditions, to further reduce the uncertainty. Besides, from Table 3, the γCO-rest and nCO-rest contribute 8.79% and 10.74% uncertainties to the CO mole fraction, respectively. We are trying to figure out the uncertainties brought by those’rest’ buffer gases.
Footnote |
† Current address: School of Energy and Environment, Southeast University, Nanjing, China. |