Zhengjie
Li
a,
Kyoung-Ho
Ha
b,
Zheliang
Wang
a,
Sangjun
Kim
b,
Ben
Davis
b,
Ruojun
Lu
b,
Jayant
Sirohi
a and
Nanshu
Lu
*abcd
aDepartment of Aerospace Engineering and Engineering Mechanics, the University of Texas at Austin, TX 78712, USA. E-mail: nanshulu@utexas.edu
bDepartment of Mechanical Engineering, the University of Texas at Austin, TX 78712, USA
cDepartment of Biomedical Engineering, the University of Texas at Austin, TX 78712, USA
dDepartment of Electrical and Computer Engineering, the University of Texas at Austin, TX 78712, USA
First published on 14th October 2022
E-skins consisting of soft pressure sensors are enabling technology for soft robots, bio-integrated devices, and deformable touch panels. A well-known bottleneck of capacitive pressure sensors (CPS) is the drastic decay in sensitivity with increasing pressure. To overcome this challenge, we have invented a hybrid-response pressure sensor (HRPS) that exhibits both the piezoresistive and piezocapacitive effects intrinsic to a highly porous nanocomposite (PNC) with carbon nanotube (CNT) dopants. The HRPS is constructed with two conductive electrodes sandwiching a laminated PNC and a stiff dielectric layer. We have simplified the hybrid response into a parallel resistor–capacitor circuit, whose output depends on the AC (alternating current) frequency used for the capacitance measurement. Herein, through theoretical analysis, we discover a dimensionless parameter that governs the frequency responses of the HRPS. The master curve is validated through experiments on the HRPS with various doping ratios, subject to different compressive strains, under diverse AC frequencies. In addition, the relative contribution of piezoresistive and piezocapacitive mechanisms are also found to vary with the three parameters. Based on this experimentally validated theory, we establish a very practical guideline for selecting the optimal AC frequency for the capacitance measurement of HRPSs.
Our recent invention of hybrid response pressure sensors (HRPSs) has broken the limit set by conventional CPSs.24 As shown in Fig. 1a, we constructed a CPS by sandwiching a laminated barely conductive porous nanocomposite (PNC) and an ultrathin dielectric layer between two parallel electrodes. The PNC is a highly porous open cell structure with tubular ligaments composed of carbon nanotube (CNT) doped Ecoflex. When the CNT doping ratio is around the percolation threshold,35 the PNC ligaments become piezoresistive and the air pores surrounded by such ligaments exhibit parasitic capacitance. As a result, the overall PNC is endowed with hybrid piezoresistivity and piezocapacitivity. The insertion of an ultrathin poly(methyl methacrylate) (PMMA) layer between the PNC and the bottom electrode tries to keep the overall sensor assembly capacitive. The experimentally measured relative capacitance change vs. applied pressure in Fig. 1b proved that the sensitivity of the HRPS outperforms all types of conventional CPSs with common dielectric materials such as Ecoflex, porous Ecoflex, and CNT doped solid or porous Ecoflex before reaching the percolation threshold. To reveal the HRPS sensing mechanism, we built an equivalent circuit as shown in Fig. 1c, where the PNC is represented by a parallel piezoresistor–piezocapacitor circuit, which is connected in series with a fixed capacitor that acts for the PMMA layer. An analytical model based on this simplified circuit was established to calculate the change of HRPS capacitance upon applied pressure.24 This model has found reasonable agreement with the experimental measurements up to a CNT doping ratio of 0.75 wt%. It offers a fundamental explanation to why the hybrid response pressure sensors afford much higher sensitivity than conventional dielectric-based CPSs. It is also able to predict the optimal CNT doping ratio that yields the best pressure sensitivity. We have demonstrated the application of a HRPS to human pulse wave detection at the surfaces of radial, carotid, and even the temporal arteries.24 We have an ongoing project to fabricate a stretchable HRPS (SHRPS) and apply it on soft inflatable grippers.
Fig. 1 (a) A schematic showing the layers of the HRPS.24 (b) The HRPS is much more sensitive than the conventional CPS.24 (c) A simplified circuit model to represent the hybrid piezoresistive and piezocapacitive responses of the HRPS. (a and b) Reproduced from ref. 24 with the permission of Wiley. |
Although the effects of CNT doping ratio have been well characterized both experimentally and theoretically, we have always used the same AC (alternating current) frequency to measure HRPS capacitance – 1 kHz,24 following the convention of a traditional CPS.3,36,37 However, while the AC frequency does not matter for the capacitance measurement of dielectric-based pure capacitors, it should play a role in the HRPS because the current division between the resistive and the capacitive branch (Fig. 1b) is tunable by the AC frequency applied. In addition to its effects on the equivalent circuit of a HRPS, the AC frequency could also affect the electrical material properties of the CNT-doped composite, such as the resistivity and the dielectric constants. According to existing experimental findings, CNT-dopped-polymer composites exhibited frequency-dependent electrical conductivity.38–41 When the AC frequency was changed over a wide range, the assumption of constant dielectric constants could also breakdown.41
These considerations prompted us to perform a systematic investigation on the effects of the AC frequency on both the HRPS and the PNC. We first carried out experiments to characterize the frequency responses of the HRPS and the PNC separately. The discovery of frequency-dependent resistance and capacitance of the PNC echoes other studies on composites in the literature. We then treated the AC frequency as a variable and reanalyzed the equivalent circuit in Fig. 1c. Our derivation yielded a master curve controlled by a single dimensionless parameter. This dimensionless parameter contains three variables—the AC frequency, the resistance of the PNC, and the capacitance of air pores. The latter two are functions of both the AC frequency and the compressive strain. Experimental validations of the master curve are provided, for various CNT doping ratios, AC frequencies, and compressive strains. Our theoretical framework has fully uncovered the interplay between the three variables as well as distinctively quantified the relative contributions of the piesoresistive and piesocapacitive mechanisms in the HRPS. Ultimately, it offers a simple guideline for selecting the optimal AC frequency to measure the capacitance of the HRPS.
Frequency sweep tests: Without applying any pressure, the capacitance of the HRPS (CHRPS) with CNT doping ratios of 0.25 wt%, 0.5 wt%, 0.75 wt%, and 1 wt% was measured using the Hioki 3532-50 with a frequency sweep from 300 Hz to 1 MHz. The applied voltage was set to be 2 V and the measurement mode was chosen to be the parallel mode. Although both resistance and capacitance readings were offered by Hioki 3532-50, only the capacitance readings are plotted in Fig. 2b. It is clear that the capacitance of the specimens with a CNT doping ratio of 0.25 wt% and 0.5 wt% is almost independent of the applied AC frequency whereas the capacitance of 0.75 wt% and 1 wt% HRPS first decreases and then reaches a plateau as the frequency increases. Specifically, the frequency where 1.00 wt% HRPS steps into a plateau is larger than that of the 0.75 wt% HRPS. In addition, at any given frequency, the capacitance increases as the doping ratio increases.
Compression tests: A dynamic mechanical analyzer (DMA, RSA-G2, TA Instruments) was used to compress the HRPS in its thickness direction. Both the compressive force and the displacement were recorded by the DMA, which can be readily converted to pressure and compressive strain. In situ capacitance measurement was performed by Hioki 3532-50. The tests were performed on four types of HRPS each under 5 different frequencies (300 Hz, 1 kHz, 10 kHz, 100 kHz, and 1 MHz) and the results are plotted in Fig. 2c–f. For all doping ratios, CHRPS increases with decreasing AC frequency. When the AC frequency went below 300 Hz, CHRPS was out of the measurement range of Hioki 3532-50. When the doping ratio increases, both the initial capacitance and the capacitance at 50 kPa increase. In addition, it is obvious that the HRPS with a greater CNT doping ratio yields a larger absolute capacitance change. These experimental results will be further explained in the Results and discussion section.
Fig. 3 (a) A schematic of the experimental setup for measuring the frequency response of PNC without and with applied pressure. Rp and Cp represent the resistance and capacitance measured by the LCR meter in the parallel mode. Frequency response of the (b) resistance and (c) capacitance of the PNC with different CNT doping ratios. R0 = Rp and Cair = Cp. Dashed curves are fitted based on eqn (2) and (3). |
The experimental measurements in Fig. 3b and c can be analytically fitted. Previous studies on universal dielectric responses42 suggested a power-law scaling relationship between the conductivity and the dielectric properties of conductive filler doped polymer composites and the applied AC frequency.38,40–42 This can be understood as follows.43 The conductive fillers in a composite could be viewed as many small elements containing resistors and capacitors in parallel. A higher AC frequency will lead to a lower impedance of the micro-capacitors, effectively resulting in an increase of the overall conductivity of composites. Therefore, the conductivity-frequency relationship of these composites can be approximated by the following empirical equation:38
σ(ω) =σdc + σac(ω) =σdc + αωs | (1) |
(2) |
Eqn (2) suggests that at low AC frequency, R0(ω) is dominated by σdc, hence it has weak dependence on frequency, which explains the plateaus at small frequencies in Fig. 3b except that for 0.25 wt%, there is no plateau in the given AC frequency range. Moreover, the DC resistance of 0.25 wt% is too large to be measured by our Keysight E4980AL LCR meter. We therefore had to obtain R0dc by extrapolating the resistance to ω = 0.1s−1, as inspired by the literature.38 As our Keysight E4980AL LCR meter has an upper limit of AC frequency of 100 kHz, we further extrapolated R0(ω) to 1 MHz as dashed curves in Fig. 3b based on eqn (1) and (2).
Fig. 3c can be fitted in a similar manner provided that we know the kair0 ∼ ω dependence where kair0 is the dielectric constant of the undeformed PNC that appears in Cair0 = kair0ε0A/t, where ε0 is the vacuum permittivity. Theoretically speaking, the capacitance of air should be independent of frequency. However, apart from the capacitance of air, PNC also has parasitic capacitance within the composite which is dependent on the CNT doping ratios and the AC frequency. According to the universal dielectric response, the dielectric constants of the conductive filler doped composites follows the power law:41,45
kair0(ω) ∼ ω−p, kair0(ω) = kair0dc + βω−p | (3) |
(4) |
We follow the fitted resistance ∼ strain relation in our previous work24 to express R as a function of both e and ω (not shown in this paper):
(5) |
During compression, both R and Cair vary with the compressive strain, while the capacitance of the dielectric layer Ci remains a constant which equals 7.08 nF in all of our specimens.
The impedance of all three components in Fig. 1c can be expressed as:
(6) |
Because ZRPNC and ZCair are first connected in parallel and then connected in series with ZCi, the impedance of the whole HRPS can be expressed as:
(7) |
Whose capacitance component is:
(8) |
If we introduce two dimensionless parameters , Y = ωRCair, we can rewrite CHRPS (after normalizing by Ci):
(9) |
Note that X2 and Y2 are correlated because they share the same variables Cair and R. The range of Cair in the parameter space we explored in our experiments was ∼300 pF before compression (1.00 wt%, 300 Hz) and 2 nF after compression. Since Ci is 7.08 nF, Ci ≫ Cair, hence X2 ≫ Y2 is always true in our problem.
Next, let's evaluate the relative magnitudes of X2, Y2 and 1.
Case I: if Y2 ≪ 1, Y2 is negligible in both the numerator and the denominator of eqn (9) such that CHRPS can be approximated as:
(10) |
Therefore, in Case I, CHRPS is only governed by a single dimensionless parameter, X. This approximate solution is plotted in Fig. 4a. In addition, if X2 ≪ 1, then:
(11) |
Fig. 4 (a) A master curve based on eqn (10) that can capture all three regimes – piezoresistive, hybrid, and piezocapacitive responses. (b) Frequency-only validation of the master curve. (c–f) Frequency and pressure validation of the master curve (black dashed curve). The colored dashed and dotted curves are based on eqn (9). Note that as the compressive strain increases, the x axis goes left. |
In this case, most of the current will flow through the piezoresistor and the piezocapacitor no longer plays a role. It corresponds to the far left limit in Fig. 4a, which is no longer a functional CPS because CHRPS is not responsive to pressure.
Case II: if Y2 ≫ 1, CHRPS could be approximated as:
(12) |
After rearrangement,
(13) |
This expression indicates that the HRPS degenerates into two capacitors connected in series, meaning that the resistive branch is negligible. It corresponds to the far right limit in Fig. 4a, which loses the hybrid response and also becomes an insensitive CPS.
With the analyses of the limiting cases, we can readily divide Fig. 4a into three regimes, each with an equivalent circuit illustrated. The two dividers are therefore X2 = ω2R2CiCair ≪ 1 between the piezoresistive and the hybrid response regimes, and Y2 = ω2R2C2air ≫ 1 between the hybrid and the piezocapacitive regimes. Thus far, we have derived a simple analytical expression for CHRPS (eqn (10)) which can be plotted into a master curve (Fig. 4a) that reveals the fundamental interplay among the resistive, capacitive, and frequency factors – in the form of a single dimensionless parameter . In addition to capturing the three equivalent circuits through the analysis of the limiting cases, the master curve offers quantitative estimations for the condition of the hybrid response of HRPS: . While the other dimensionless parameter (Y = ωRCair) is not included in the master curve, Y has a clear physical meaning which will be discussed in Section 4.3.
Because R and Cair are functions of the CNT doping ratio and the compressive strain, the experimental validation of the master curve will involve many different scenarios and it is very interesting to see how well the master curve can capture those diverse situations and where the limits of the master curve are.
When pressure is applied, another variable, e, which is obtained as the ratio of the compressive displacement to the initial thickness of HRPS, comes into play. To best display the results of three variables, CNT doping ratio, ω, and e, we plot CHRPS/Civs. in four different charts, each with a fixed CNT doping ratio and variable ω in different colors (Fig. 4c–f). Each colored curve in Fig. 4c–f therefore represents a compression experiment on a HRPS with a fixed CNT doping ratio under a fixed ω. And when e (i.e., applied pressure) increases, the x axis goes left. Note that the y axes of Fig. 4c–f have different scales. A few important observations can be made by comparing the experimental results with the master curve. (1) The master curve agrees well with the low frequency experiments on 0.5 wt%, 0.75 wt%, and 1 wt% HRPS. This is because the master curve given by eqn (10) has a prerequisite that Y = ωRCair ≪ 1, which can be met when ω is small. (2) When ω is too large for Y = ωRCair ≪ 1 to hold, we plot the exact solution eqn (9) as the colored dashed curves in Fig. 4c–e and find them to have good agreement with the experimental results measured under high frequencies. (3) When the CNT doping ratio is 1 wt%, eqn (4) no longer captures the experimental relationship between Cair and e. We therefore assume a power law given by ESI† eqn (S2) to fit the experimentally measured Cair with the fitted exponents given in the ESI† Table S2 and the fitted curves plotted as dashed curves in the ESI† Fig. S2d. Replacing eqn (4) by ESI† eqn (S2), eqn (9) is replotted as the colored dotted curves in Fig. 4f, which are in excellent agreement with the experimental curves, indicating that our overall theoretical framework still holds. (4) In general, neither the master curve nor the exact solution can well predict the experimental results of the 0.25 wt% HRPS, which may be due to the inaccurate R0 that was extrapolated following ref. 38 because it was too large to be measurable by our LCR meter. (5) All of our experiments only operated in the regimes of piezocapacitive and hybrid responses. (6) Fig. 4c–f are not the most straightforward plots for HRPS sensitivity discussions because they are plotting CHRPS instead of ΔCHRPS. When it comes to sensitivity evaluation, we have to examine ΔC/C0, in which C0 plays a big role. As a result, although the absolute change of CHRPS appears to be the largest in 1 wt% specimens, the most sensitive specimens were actually the 0.5 wt% ones (see the ESI† Fig. S3b).24 With this point in mind, at given doping ratios of 0.5 wt% (Fig. 4d) and 0.75 wt% (Fig. 4e), it is still obvious in those figures that ω = 300 Hz offers the best sensitivity, which happens to be the cases that are best traced by the master curve.
ĪR = IR/(IR + ICair), ĪCair = ICair/(IR + ICair) | (14) |
Due to the parallel connection, there is an intrinsic trade-off between them:
ĪR + ĪCair = 1 | (15) |
Furthermore,
(16) |
Therefore, the physical meaning of Y is actually the ratio of the current flowing through the capacitive branch to that of the resistive branch. This explains why (Y2 ≫ 1) represents the piezocapacitive regime and (Y2 ≪ X2 ≪ 1) represents the piezoresistive regime in Fig. 4a. With the legends given in Fig. 4b, the two fractions of current are plotted in Fig. 6c–f, and each represents a CNT doping ratio. It is clear that a higher AC frequency leads to a larger current flow through the capacitive branch. Moreover, in Fig. 6c–e, ĪCair starts higher than ĪR but the former decreases whereas the latter increases with compression. A cross-over between the two indicates that there is a swap of the dominating mechanism as the compression progresses – from piezocapacitivity to piezoresistivity. This can be easily understood as follows: before the compression, there are large air pores and the deformation of those air pores mainly drives the change of CHRPS at small pressure; when the pressure is large, the air pores are compressed and the conductive ligaments start to make contacts such that the piezoresistivity becomes dominant. Among the five frequencies examined, the optimal frequency observed from Fig. 4c–e is the one that keeps the two current fractions closest to 0.5, suggesting that the scenario with the most balanced hybrid response has the best sensitivity. For 1.00 wt%, the optimal frequency also shares this characteristic (Fig. 6f). Detailed explanations are provided in the ESI.†
Footnote |
† Electronic supplementary information (ESI) available. See DOI: https://doi.org/10.1039/d2sm01250b |