Qaisar
Maqbool
a,
Nevzat
Yigit
b,
Michael
Stöger-Pollach
c,
Maria Letizia
Ruello
a,
Francesca
Tittarelli
a and
Günther
Rupprechter
*b
aDepartment of Materials, Environmental Sciences and Urban Planning (SIMAU), Università Politecnica delle Marche, INSTM Research Unit, via Brecce Bianche 12, 60131 Ancona, Italy
bInstitute of Materials Chemistry, TU Wien, Getreidemarkt 9/BC, A-1060 Vienna, Austria. E-mail: guenther.rupprechter@tuwien.ac.at
cUniversity Service Center for Transmission Electron Microscopy, TU Wien, Wiedner Hauptstr. 8-10, 1040 Vienna, Austria
First published on 14th December 2022
The sensing of volatile organic compounds by composites containing metal oxide semiconductors is typically explained via adsorption–desorption and surface electrochemical reactions changing the sensor's resistance. The analysis of molecular processes on chemiresistive gas sensors is often based on indirect evidence, whereas in situ or operando studies monitoring the gas/surface interactions enable a direct insight. Here we report a cross-disciplinary approach employing spectroscopy of working sensors to investigate room temperature methanol detection, contrasting well-characterized nanocomposite (TiO2@rGO-NC) and reduced-graphene oxide (rGO) sensors. Methanol interactions with the sensors were examined by (quasi) operando-DRIFTS and in situ-ATR-FTIR spectroscopy, the first paralleled by simultaneous measurements of resistance. The sensing mechanism was also studied by mass spectroscopy (MS), revealing the surface electrochemical reactions. The operando and in situ spectroscopy techniques demonstrated that the sensing mechanism on the nanocomposite relies on the combined effect of methanol reversible physisorption and irreversible chemisorption, sensor modification over time, and electron/O2 depletion–restoration due to a surface electrochemical reaction forming CO2 and H2O.
Metal oxide semiconductors (MOScs) such as In2O3, ZnO, WO3, SnO2, NiO, Co3O4, CuO, etc. have been widely used as VOC gas sensing materials, based on their resistivity change upon exposure to analytes (chemiresistivity).6–12 To achieve higher sensitivity at relatively low working temperatures, MOScs have been doped with noble metals such as Au, Ag, Pt, Pd, etc.13–16 Still, conventional MOScs typically require working temperatures of 90–400 °C to desorb water chemisorbed on the sensor surface and to provide free sites for analyte chemisorption.17 High MOSc working temperatures maintain the sensitivity toward VOCs over repeated cycles,18,19 but induce high-power consumption, reduce the sensor lifetime and pose a security risk for sensor operation in a flammable environment.6–11
The next generation of VOC sensors thus operates at room temperature (RT), benefitting from power-saving, eco-friendliness, sustainability, and higher safety.20,21 Recently, several materials have been tested as RT-VOC sensors, such as carbon-based materials including multiwall carbon nanotubes with polyaniline, carbon derivatives in polyetherimide with a liquid crystal polymer, and graphene doped polyaniline. These sensors were able to detect methanol vapor of 50–500 ppm, 300–1200 ppm, and 50–100 ppm, respectively.22–24 Moreover, MOSc based materials, such as CdO with polyaniline and a thin layer of Au, Ag, Pt or Cu on top of In2O3–SnO2, have also shown detection limits of 100 ppm and 200–900 ppm, respectively. When In2O3 was combined with Ti3C2Tx (an MXene), methanol detection was further enhanced (5–100 ppm). Nevertheless, CdO and In2O3 possess significant toxicity to humans: carcinogenic effect, renal toxicity, alveolar proteinosis, emphysema or interstitial fibrosis.25,26 Thus, in terms of biocompatibility, using TiO2 nanomaterials as RT-VOC sensors has attracted attention. TiO2 nanotubes and quantum dots exhibited promising methanol sensitivity of 100–300 ppm and 1000 ppm at RT, respectively27,28 However, the sensors' response time and detection limit were rather high or required UV light for sufficient performance.
For MOSc-based VOC sensing devices, changes in electrical resistance and response–recovery times upon exposure to variable VOC concentrations have been reported repeatedly, but the sensing mechanism was often described rather hypothetically.17 To obtain a fundamental understanding of the sensor's functional properties rather requires real-time studies of the working sensor surface interacting with VOCs, i.e., an in situ or operando approach hardly attempted before. Even more so as VOCs may irreversibly bind to MOScs, limiting the sensor functionality. For instance, methanol irreversibly adsorbs on nanocrystalline TiO2 and requires ≈425 °C for removal of the adsorbed methoxy species.29 Similarly, methanol adsorbs dissociatively on pure ZnO, as well as on ZnO decorated with Au nanoparticles, thus requiring 275–320 °C for operation. It was also reported that Au enhanced the ZnO reducibility and facilitated the generation of oxygen vacancies,30 which is considered an important factor in VOC sensing by MOSc surfaces.
To improve the current understanding, we have combined and linked surface sensitive vibrational studies31–33 of metal/oxide nanomaterials with RT sensor technology, simultaneously monitoring methanol–surface interactions and the corresponding resistance changes in real time. Operando diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS) and in situ attenuated total reflectance-Fourier transform infrared spectroscopy (ATR-FTIR) were applied to evaluate the methanol gas sensing performance of green-synthesized and well-characterized TiO2 nanoparticles, reduced graphene oxide (rGO) and their nanocomposite (TiO2@rGO-NC). Based on simultaneous mass spectroscopy, the mechanism of room temperature methanol gas sensing was directly confirmed. Furthermore, the multidisciplinary approach presented herein may stimulate analogous in-depth studies and the development of versatile RT-VOC sensors.
A transparent glass substrate (dimensions: 3.2 cm × 2.4 cm), silver electrodes (purity = 99%, dimensions: 6 cm × 0.2 cm), precision digital multimeter (UNI-T® UT61E), sensor/electrode multimeter-connector (PalmSens®), hotplate magnetic stirrer-RH basic (IKA®, Germany), water bath ultrasonicator (FALC®, Italy), heating oven (LAPORTA®, Italy), electric grinder (KENWOOD® 500 W), centrifuge (ECCL31R Multispeed, Thermo Scientific®, USA), Brunauer–Emmett–Teller (BET) analyzer by Micromeritics®-ASAP-2020, X-ray powder diffractometer (Bruker®), TGA (Mettler®-851), UV/vis spectrometer (Lambda 750, PerkinElmer®), diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS) using a Bruker Vertex 70 spectrometer with a DRIFTS cell (Pike), attenuated total reflectance-Fourier transform infrared (ATR-FTIR) spectrometer (Vertex-70, Bruker Optics®), ZnSe crystal (dimensions: 52 mm × 20 mm × 2 mm), quadrupole mass spectrometer (QMS) (Prisma Plus QMG 220, Pfeiffer Vacuum), high resolution transmission electron microscopy (HR-TEM) using an FEI TECNAI F20 field emission microscope.
i. Mature olive leaves, as a potential waste harvested in November, were thoroughly washed with dH2O to remove solid particles (impurities) and dried at room temperature in the dark to avoid photodissociation of secondary metabolites. To ensure repeatability and to match the metabolic profile necessary for TiO2-NP synthesis, it is important that the olive leaves are collected at a specific time of the year (preferentially November). The harvested leaves should be stored at >57% humidity at room temperature for further use.36
ii. The dried olive leaves were ground to a fine powder. For water extract preparation, 25 g of the olive leaf powder was soaked in 500 mL of diH2O for 12 h, and then heated to 85 °C for 3 h in a hot water bath. The suspension was allowed to cool to room temperature and was filtered using Whatman filter paper no. 1 to obtain an olive leaf extract.
iii. 500 mL of the prepared extract in a reaction flask was put on a hot plate magnetic stirrer at 85 °C and 150 rpm. Thereafter, 0.1 M TiOSO4·xH2SO4·yH2O was added to the preheated extract. After 20 min, the pH of the reaction mixture was adjusted to ∼4 by dropwise addition of 3 M NaOH solution. Next, heating was turned off and the reaction mixture was cooled to room temperature while stirring at 150 rpm.
iv. TiO2-NPs were collected by centrifugation at 8000 rpm and washed three times with diH2O to remove uncoordinated secondary metabolites from the extract. TiO2-NPs were dried in a hot air oven at 90 °C for 24 h. Next, the dried TiO2-NPs were calcined at 350 °C for 3 h in a furnace before being kept in an airtight jar for further use.
v. The production of reduced graphene oxide (rGO) was achieved by adding 2 g of graphite powder in a reaction flask immersed in an ice-water bath and maintained below 10 °C. After this, 100 mL of concentrated H2SO4 was added under continuous stirring. Then, 6 g of KMnO4 was gradually added. Next, the suspension was stirred at room temperature for 20 min followed by 10 min ultrasonication and stirring (process repeated 10 times). Subsequently, the reaction was quenched by addition of 400 mL diH2O and further ultrasonicated for 2 h. The suspension pH was adjusted at ∼6 by addition of 1 M NaOH solution, which was further ultrasonicated for 1 h. Then, 20 g of L-ascorbic acid was dissolved in 200 mL diH2O and slowly added to the suspension at room temperature while increasing the temperature to 95 °C for 1 h. The rGO was recovered by filtration using cellulose filter paper and washed with 1 M HCl solution and diH2O to achieve neutral pH. Finally, the filtrate was vacuum-dried to obtain rGO pellets.
vi. Different weight ratios (25%, 50%, and 75%) of TiO2-NPs were homogenized with rGO to prepare TiO2@rGO-NC. Typically, TiO2-NPs and rGO were mixed in the presence of diH2O (ratio of 100 mg of solid in 2 mL of liquid) and ultrasonicated for 15 min to ensure proper homogenization of TiO2-NPs and rGO. One part of the as-prepared paste (TiO2@rGO-NC) was deposited between two Ag-electrodes to produce a sensor. The remaining part was dried at 90 °C in an oven to remove water and kept for further use in characterization studies.
vii. The sensor design comprises 3 components: two Ag-electrodes (6 cm × 0.2 cm), a glass substrate (3.2 cm × 2.4 cm) and a thin layer (≈25 μm) of sensing material (e.g., TiO2@rGO-NC) deposited between the Ag-electrodes. The Ag-electrodes were immobilized with adhesive on the glass substrate and with the distance between the two Ag-electrodes matching the multimeter connector for resistance measurements.
viii. After deposition of the sensing material between the two Ag-electrodes, each sensor was stabilized and dried at 60 °C in an oven for 24 h. The prepared sensors were stored in a desiccator for further use.
The morphology and crystal structure of the various materials (TiO2-NPs, TiO2@rGO-NC) were evaluated by high resolution-transmission electron microscopy (HR-TEM), electron energy loss spectrometry (EELS) and selected area electron diffraction (SAED), using an FEI TECNAI F20 field emission microscope equipped with a GATAN GIF Tridiem energy filter and a GATAN Rio16 CMOS camera. For HR-TEM, the samples were prepared as follows: 5 mg TiO2-NPs (or TiO2@rGO-NC) and 5 mL diH2O were ultrasonicated for 20 min. Using a micropipette, 1 drop of the ultrasonicated suspension was deposited on a commercial TEM copper grid covered with a lacy carbon film. Before each measurement, the TEM sample was vacuum dried for 10 min.
Brunauer–Emmett–Teller (BET) analysis of the as-prepared materials (TiO2-NPs, rGO and TiO2@rGO NC) was carried out on a Micromeritics surface area and porosity analyzer. To determine the specific surface area (SSA), N2 adsorption at −196 °C was performed on an ASAP 2020 Micromeritics apparatus on 0.5 g sample, preheated under vacuum (<0.013 mbar) at 50 °C for 3 h. Evaluation of the SSA was based on the linear part of the BET analysis, and pore size distributions were obtained by applying the Barrett–Joyner–Halenda (BJH) equation to the isotherm desorption branch, and the total pore volume was estimated from the N2 uptake at a P/P0 of 0.99.
Thermogravimetry (TG), derivative thermogravimetry (DTG) and simultaneous differential thermal analysis (SDTA) of the as-prepared TiO2-NPs, rGO and TiO2@rGO NC were used to monitor the thermal properties in terms of mass change and exothermicity/endothermicity, both in air and nitrogen. The gas flow was set to 60 mL min−1 in the temperature range of 25–1000 °C, with a rate of 10 °C min−1. For each sample, 5–20 mg of the dried powder sample were measured in an alumina-150 μL sample holder.
The methanol molecules (gas) vs. chamber air molecules were calculated accordingly:
Density of methanol (room temperature) = 0.7913 g mL−1 |
1 μL = 0.001 mL |
0.001 mL × 0.7913 g mL−1 = 0.0007913 g = 0.7913 mg |
X = 0.7913 mg × 6.022 × 1023 molecules per mol/32040 mg |
X = 1.4875 × 1019 molecules |
Y = 6.022 × 1023 molecules per mol × 200 mL/24460 mL |
Y = 4.9240 × 1021 molecules |
So, the methanol molecules per air molecules are
1.4875 × 1019/4.9240 × 1021 = 0.003 (3000 ppm) |
The electrical resistance R was measured using a high-resistance multimeter, read out by UT61E software (v.4.01). The response time and recovery time of the sensor were calculated using eqn (1) and (2) which are shown in Fig. 4B,
Response time = Tmax − Tstart | (1) |
Recovery time = Tbaseline − Tmax | (2) |
Response time is defined as the time of maximum (100%) alteration in resistance in the presence of methanol (Tmax) minus the time at which the methanol pulse was started (Tstart). Recovery time is defined as the time needed by the sensor to achieve the baseline (resistance in air) (Tbaseline) after pulsing methanol minus the time of maximum (100%) alteration in resistance upon methanol pulsing (Tmax).
Finally, for temperature-programmed methanol desorption, the sample was heated to 450 °C (10 °C min−1) in the DRIFTS cell while recording the IR spectra.
The crystallography of the as-prepared TiO2-NPs, rGO and a nanocomposite of TiO2-NPs and rGO (TiO2@rGO-NC) was examined by X-ray diffraction (XRD). The broad diffraction peaks (Fig. 1B) revealed the small crystallite size of the green synthesized TiO2-NPs. The Bragg peaks were in good agreement with ICDD 04-016-2837,39 indicating that TiO2-NPs were anatase.28 The crystal structure of TiO2-NPs was further evaluated via Rietveld refinement (Fig. 1B and S1†), showing unit cell parameters of a = 3.79 Å, b = 3.79 Å and c = 9.48 Å. The average crystallite size of TiO2-NPs was calculated using Debye–Scherrer's equation:
D = 0.9λ/βcosθ | (3) |
The XRD patterns of rGO and TiO2@rGO-NC are shown as an inset of Fig. 1B. The broad peak of rGO at 2θ = 25.27° indicates that thick carbon stacks of graphite segregated into a few layers of rGO, as commonly observed during exfoliation of graphite into graphene, graphene oxide or rGO.40 The results are also consistent with the powder UV-vis spectra of rGO (Note S1 and Fig. S2†). Furthermore, XRD confirmed that the structural properties of TiO2-NPs remained unchanged upon preparation of the nanocomposite (TiO2@rGO-NC).
The grain size of anatase (Fig. 1C), as determined by high-resolution transmission electron microscopy (HR-TEM) under extended Scherzer conditions, was found to be <6 nm, in good agreement with XRD. The fine-grained polycrystalline areas (Fig. 1C) were identified to be anatase by means of selected area electron diffraction (SAED; inset of Fig. 1C) and via the energy loss near edge structure (ELNES). The recorded ELNES, as shown in Fig. S3A,† is clearly characteristic of anatase-TiO2 (more details in Note S2†). The observed lattice planes are attributed to the (101) planes of anatase.
TiO2-NPs possess tremendous surface catalytic potential;41,42 however, green synthesized, homogeneous and small sized TiO2-NPs have been scarcely reported in the literature.43,44 Recently, anatase-TiO2 quantum dots with a crystallite size of 4.2 nm were obtained by chemical synthesis in a time-consuming and complex procedure utilizing acetylacetone, n-butanol, and 4-dodecylbenzene sulfonic acid.28 In the current study, TiO2-NPs with a small crystallite size (∼4 nm) and a homogeneous morphology seem to result from the synergistic effect of secondary metabolites from olive leaves, reaction temperature, and optimized pH. Maurya et al. described green synthesized TiO2 NPs of 13 nm in size of the pure anatase phase, whereas NPs prepared by a chemical synthesis method were 16 nm large.45 Also, Tsega et al. reported pure anatase-TiO2-NPs in a pH range between 4.4 and 6.8. A drastic change in crystallite size from 24 to 8 nm was observed when the pH was lowered to ∼3.2; but it also resulted in a loss of phase purity.46 A similar effect of low pH on the TiO2-NP phase purity was observed by Isley et al.47 Hence, a pH of ∼4 seems to be the borderline to achieve pure anatase TiO2-NPs.44
The large flakes of graphene (rGO) (Fig. S3B†) yielded a single crystalline SAED pattern (Fig. 1D), showing the typical hexagonal symmetry of (0001) orientation. The TiO2@rGO nanocomposite (Fig. S3B†) exhibited a homogeneous distribution of TiO2-NPs within the rGO matrix.
As sensor materials may need higher temperatures for operation or reactivation, the thermal properties of the prepared nanomaterials were analyzed by thermogravimetry (TG), derivative thermogravimetry (DTG) and simultaneous differential thermal analysis (SDTA) (Fig. 1E and S4†). The temperature of maximum decomposition (Tn), the relative weight loss (Δm) and the temperature of 5% mass loss (defined as the decomposition temperature, Td) are summarized in Table S3† for each material. The thermal analysis of TiO2@rGO-NC (Fig. 1E) was distinctively different from that of TiO2-NPs and rGO (Fig. S4†), showing intermediate values. In air, the first weight loss until 150 °C is due to the removal of water. This endothermic process overlaps at T > 200 °C with the exothermic thermal decomposition of organic compounds and a maximum weight loss at T = 290 °C. At T > 400 °C, due to the presence of oxygen, a sharp oxidative decomposition of graphene occurred with an exothermic peak and a Tn of 576 °C. The presence of TiO2-NPs increased the thermal stability of graphene in air, increasing the temperature of maximum weight loss from T = 531 °C to 576 °C, while the Td increased from 290 °C to 314 °C. For T > 650 °C no further weight loss was recorded. This demonstrates that the TiO2@rGO-NC is thermally stable up to at least 300 °C and would be compatible with high temperature sensing. The thermal stability of the other sensor materials is presented in Note S3, Fig. S4 and Table S3.†
The specific surface area (SSA) of the sensing materials is an important factor for the interaction with analyte molecules and was measured using N2 adsorption–desorption isotherms, calculated by the Brunauer–Emmett–Teller (BET) and Barrett–Joyner–Halenda (BJH) (dV/dw) methods. The BET surface areas of TiO2-NPs, rGO and 50 wt% TiO2@rGO-NC were 101.5 m2 g−1, 36.4 m2 g−1 and 70.8 m2 g−1, respectively. Moreover, the BJH cumulative pore volume and pore width of TiO2-NPs, rGO and 50% TiO2@rGO-NC were 0.11 cm3 g−1 – 5.9 nm, 0.13 cm3 g−1 – 37.4 nm and 0.08 cm3 g−1 – 6.8 nm, respectively, as depicted in Fig. S5 (more details in Note S4†). Accordingly, upon preparation of the TiO2@rGO-NC the SSA was preserved. Not unexpectedly, the high SSA of TiO2-NPs is beneficial for MeOH sensing.28,48,49
Fig. 2D shows the DRIFTS spectra for various methanol concentrations and sensor materials, displaying the maximum peak intensities of each (the relative absorbance scales nearly linear with the methanol concentration; Fig. S9†), as well as those after purging. The spectra in the C–H stretching vibration range, with intensities in the order TiO2-NPs > TiO2@rGO-NC > rGO, characterize the adsorbed species. The absorption bands between 2800 and 3000 cm−1 result from ν(CH3) vibrations of physisorbed methanol and chemisorbed methoxy (CH3O). The spectra of methanol in the absence of a sensor (on the aluminum mirror; positive control) and of the background (sensor in pure synthetic air (SA); negative control) are included in Fig. 2D for reference. Interestingly, after sample purging by flowing synthetic air, all peaks disappeared for rGO, whereas some remained for TiO2 and TiO2@rGO-NC. This clearly demonstrates the important role of TiO2-NPs, and that most of the methanol adsorption was still reversible. To fully remove the irreversible CH3O species from TiO2via recombinative desorption, temperatures >400 °C are needed (Fig. 2E and S10†). This also explains the initial baseline shifts in resistance upon methanol sensing, which are attributed to irreversible methoxy adsorption modifying the sensor resistance. Fig. S10† further validates the correlation between the concentration of TiO2-NPs (0, 25, 50 and 75% in rGO) versus the initial baseline shift (sensor stability) resulting from irreversible CH3O adsorption on TiO2-NPs at room temperature. The higher the TiO2-NPs concentration, the higher the baseline distortion, thus affecting the sensor performance over time.
To study the interaction of the sensor materials with the analyte in more detail, liquid methanol was examined by in situ ATR-FTIR in the range of 1000–3600 cm−1, as shown in Fig. 3 (with magnified insets of selected ranges) and Fig. S11–S13.† Once more, TiO2-NPs enhanced the interaction, confirming the results for gaseous methanol.
After drying in He, the ATR of methanol adsorbed on TiO2 showed four resonances at 2821, 2850, 2923, and 2950 cm−1. The first two peaks are assigned to the νs(CH3) mode of chemisorbed methoxy (CH3O) and physisorbed CH3OH on TiO2, respectively. The latter two peaks result from the Fermi resonance of chemisorbed methoxy (νF1, CH3O) and physisorbed methanol (νF2, CH3OH), respectively.50–53 Manzoli et al. reported that the bands between 2000 and 1000 cm−1 may be related to differently coordinated methoxy species on TiO2, with the band at 1156 cm−1 characterizing on-top methoxy species on Ti3+ near an oxygen vacancy. The band at 1135 cm−1 may be due to on-top species on Ti4+ sites.54 The shoulder at 1025 cm−1 and the peak at 1120 cm−1 were previously assigned to ν(C–O) of methanol physisorbed and chemisorbed on TiO2, respectively.55
Fig. 4 Methanol gas sensing performance of different materials: (A) room temperature methanol sensing by 50%TiO2@rGO-NC and rGO at different concentrations (left) and linear fit (right), (B) illustration of the sensor response and recovery time measurement, (C) sensor performance with respect to the response and recovery time, (D) reproducibility of room temperature methanol gas sensing for 50%TiO2@rGO and rGO at higher and ∼10-times lower methanol concentration. For even lower concentrations, see Fig. S14,† and (E) comparison of the room temperature methanol sensing response time of the current and previously reported materials (for more details, see Table S4†). |
Fig. 4A shows the relationship between the methanol gas stimulus at room temperature and the induced resistance change. It is apparent that the response increased linearly with methanol concentration. As shown in Fig. 4B, the response time of the sensor is defined in terms of time needed by the sensor to achieve 100% alteration in resistance for a particular methanol gas stimulus, while the recovery time refers to the time taken to recover from 100% to the baseline. Overall, 50% TiO2@rGO-NC showed the shortest response time of ∼15 s for both 1.5 × 104 and 1.8 × 104 ppm. Moreover, it is also clear from Fig. 4A and C that addition of TiO2-NPs to rGO not only shortened the sensor response time, but also the recovery time, with the latter being equally important for RT sensor operation.27 Apart from the linearity of resistance vs. methanol concentration and the response–recovery behavior, the signal reproducibility at both 3 × 103 and 2.1 × 104 ppm methanol was tested (Fig. 4D), with both sensing materials (TiO2@rGO-NC and rGO) showing excellent reproducibility. Additionally, the estimated limit of detection (LOD defined as 3 times the standard deviation SDV of the sensor in SA (baseline values without methanol gas), divided by the slope of the linear part of the calibration curve)56 was ∼213 and ∼847 ppm for the 50% TiO2@rGO-NC sensor and rGO, respectively. Moreover, the TiO2@rGO-NC also exhibited methanol sensitivity at much lower methanol concentrations of 75 to 150 ppm, as shown in Fig. S14.†
In light of previous studies (Fig. 4E), the current TiO2-NPs and the nanocomposite exhibit promising properties for methanol sensing, outperforming many previously reported materials in the response time. When synthesized by a chemical method, TiO2-quantum dots were able to detect 1000 ppm of methanol vapor at room temperature with a response time of ≈200 s.28 Similarly, Ti as a two-dimensional metal carbide (MXene) could detect 100 ppm of methanol gas at room temperature with a response time of ≈300 s.57 The detailed comparison in Table S4 shows the relevance of the TiO2@rGO-NC sensor obtained via a facile green synthesis, exhibiting good methanol sensitivity, short response/recovery time and reproducibility/stability, with the methanol sensing process even examined by operando spectroscopy herein.
O2(gas) → O2(ads) | (4) |
O2(ads) + e− → O2−(ads) | (5) |
O2−(ads) + e− → 2O−(ads) | (6) |
O−(ads) + e− → O2−(ads) | (7) |
The resistance of the rGO was around 100 ohms with a p-type response, and addition of TiO2 increased the resistance to around 200 Ω. Even more importantly, addition of TiO2-NPs to the rGO matrix significantly improved the sensor performance. The first methanol exposure resulted in physisorbed CH3OH and chemisorbed methoxy (CH3O), the latter being responsible for the baseline shift. Hence, reversible and irreversible RT methanol adsorption on the surface of the sensing materials controls the baseline shift and stability over time.
CH3OH + 3O2− → CO2 + 2H2O + 6e− | (8) |
h+ + e− → null | (9) |
To observe this process in real time, at least in part, the methanol gas sensing chamber was connected to a mass spectrometer (MS), as shown in Fig. 5A. This allowed us to link resistance changes upon methanol stimulation with simultaneous gas phase analysis, once more in an operando mode (Fig. 5B). The MS detection allowed identification of products of the surface electrochemical reaction. At varying concentrations of methanol (3 × 105–9 × 105 ppm), H2O and CO2 were traced as products of methanol reacting with pre-adsorbed oxygen, according to eqn (8) and Fig. 5C.
Methanol conversion to CO2 and H2O due to the surface electrochemical reaction was thus evident from MS, with the tailing MS signals indicating persistent room temperature methanol oxidation. This once more highlights the importance of methanol adsorption–desorption on the surface and interfaces of TiO2-NPs for the resistance changes. Electron paramagnetic resonance (EPR) spectroscopy could even directly detect the formation of reactive oxygen species.64
However, the production of H2O by the surface electrochemical reaction or a high humidity at room temperature may affect the sensor performance. To address this issue, methanol gas together with vaporized H2O (1:36) was introduced to the sensing chamber. Under highly humid conditions (75 ppm methanol in 2925 ppm H2O), one expects a loss of functionality, but the sensor still detected up to 150 ppm methanol in 5850 ppm H2O before collapsing (Fig. S14†). This confirms that the sensing material is highly selective towards MeOH over H2O, as well as resistant towards co-dosed H2O.
Footnote |
† Electronic supplementary information (ESI) available: Supplementary Notes S1–S4, Fig. S1–S14, Tables S1–S4. See DOI: https://doi.org/10.1039/d2cy01395a |
This journal is © The Royal Society of Chemistry 2023 |