Katharina
Matura
a,
Rosarita
D’Orsi
b,
Laura
Spagnuolo
b,
Felix
Mayr
a,
Munise
Cobet
a,
Christoph
Putz
c,
Alessandra
Operamolla
b and
Serpil
Tekoglu
*a
aLinz Institute for Solar Cells (LIOS) and Institute of Physical Chemistry, Johannes Kepler University Linz, Altenberger Str. 69, A-4040, Linz, Austria. E-mail: serpil.tekoglu@jku.at
bDepartment of Chemistry and Industrial Chemistry, University of Pisa, Via Giuseppe Moruzzi 13, I-56124, Pisa, Italy
cDivision of Soft Matter Physics and Institute of Experimental Physics, Johannes Kepler University Linz, Altenberger Str. 69, A-4040, Linz, Austria
First published on 27th September 2024
Mixed ionic–electronic conductors (MIEC) are pivotal in advancing medical diagnostics, therapeutic devices, and health monitoring solutions due to their unique properties that enable more effective interfaces between electronic devices and biological systems. Cellulose, a natural and abundant polymer, is a promising material in the development of MIECs for bioelectronics. Combining cellulose with conductive polymer components can leverage the biocompatibility, sustainability, and mechanical properties of composite materials. In this study, we highlight the sulfated cellulose nanocrystals (S-CNCs) as a template for the facile green synthesis of conductive polymer PEDOT (poly(3,4-ethylenedioxythiophene)). The PEDOT:S-CNCs nanocomposite possesses good conductivity and high dispersibility in water. The electronic conductivity is recorded up to 5 S cm−1. A comprehensive investigation for material characterization is associated with the changes in their micro- and nanostructure surface morphology. The biocomposite is deposited as a channel material in organic electrochemical transistors (OECTs) to analyze ion-to-electron transduction. The maximum transconductance values are obtained up to 13.6 mS and 44.3 mS for single-channel and interdigitated OECTs, respectively, without applying photolithography techniques. The high transconductance values reveal the great potential of PEDOT:S-CNCs composite for bioelectronics.
Cellulose, the most abundant polymer in nature, is emerging as a promising material in the development of biomedical applications such as tissue engineering, wound dressing, and drug delivery.12 Being a renewable resource, cellulose contributes to the development of sustainable and eco-friendly materials. The hydroxyl groups on cellulose can be chemically modified, allowing for functionalization and improved interaction with other materials. Cellulose nanocrystals (CNCs) and cellulose nanofibrils (CNFs) have been investigated as reinforcement material for conductive polymers such as PEDOT:PSS, PPy, and polyaniline (PANI) for flexible energy and electronic devices.13–17 Nanocellulose has been mostly blended with conductive polymers to enhance the mechanical stability and flexibility of conductive composites.14,15
The hydroxyl groups on cellulose can be functionalized to introduce ionic groups to template conductive polymers, improving the ionic and electronic transport properties. In particular, CNCs are promising to graft conductive polymers due to excellent hydrophilicity with polar groups, tunable surface chemistry, high mechanical strength, and biodegradability.18 Additionally, CNCs can perform as multifunctional nanoplatforms for bioelectronics and biosensing.19 In the surface grafting method, conductive materials can be tightly bonded onto nanocellulose as a biotemplate via ionic interaction. The sulfated CNCs (S-CNCs) exhibit a negative surface charge, which drastically enhances their dispersibility in aqueous media.20 The polyelectrolyte nature of S-CNCs makes it an anionically charged rigid polyelectrolyte as a counterpart for the electronically conductive and cationic polymer PEDOT, resulting in p-type mixed ionic–electronic conductors.16,21,22 S-CNCs display rod-like morphology, whereby their length and width can range from 70–500 nm and 2–20 nm, respectively.23–25 In general, these CNCs show amphiphilic characteristics, which originate from the dual presence of hydrophilic sites (polar) and hydrophobic sites (non-polar). Owing to this property, CNCs have been previously employed to increase the stability of pickering emulsions.23,26 PEDOT-CNCs samples with poor dispersibility can promote significant phase separation in their thin films. The electrical conductivity is strongly dependent on phase separation, and electronic transport between conductive sites can be a limiting factor.13–16,22 The insulating CNC-rich domains may block the pathways between the PEDOT-rich domains, resulting in low electrical conductivities up to ∼200 μS cm−1.16 Therefore, nanocellulose-based composites with stable dispersion of PEDOT and uniform thin-film formation are crucial to achieve high ionic and electronic conduction.
In this work, we incorporate biodegradable cellulose nanocrystals as rigid rod nanoparticles in a p-type MIEC. PEDOT:S-CNCs are synthesized by following two steps. The first step is the preparation of sulfated cellulose nanocrystals through acid hydrolysis. As the second step, subsequent polymerization of 3,4-ethylenedioxythiophene (EDOT) monomer is carried out by chemical oxidation. The in situ oxidative polymerization of EDOT is templated by S-CNCs and represents a facile green synthesis in aqueous solution. The resulting PEDOT:S-CNCs nanocomposite possesses good conductivity, high dispersibility in water, and beneficial phase separation morphology in the solid state. The findings reveal high electronic conductivities up to 5 S cm−1. A comprehensive study is conducted using attenuated total reflection Fourier-infrared (ATR-FTIR) spectroscopy, X-ray photoelectron spectroscopy (XPS), and Raman spectroscopy for material characterization. The morphological changes are recorded by using scanning electron microscopy (SEM), atomic force microscopy (AFM), and polarized light microscopy to examine their micro- and nanostructures. To validate their ion-to-electron transduction, the composites are successfully deposited via solution processing (spin-coating) as a channel material in organic electrochemical transistors (OECTs). The maximum transconductance (gmax) values of 13.6 mS and 44.3 mS are obtained for single-channel and interdigitated OECTs, respectively, after optimizing the device parameters, without applying photolithography techniques.
The novel PEDOT:S-CNCs biocomposite was synthesized by adapting the previously reported procedure for the PEDOT:DNA composites.11 Accordingly, EDOT was oxidatively polymerized in a suspension of S-CNCs after adding EDOT with the 1:1 weight-to-weight monomer ratio to S-CNCs. The EDOT/S-CNC mass ratio of 1 was chosen to obtain high electrical conductivity while maintaining the uniformity and stability of the PEDOT:S-CNC dispersion.21 During the oxidative chemical polymerization of EDOT, the as-formed PEDOT chains possess positive charges, exploited to interact with the dispersed negatively charged S-CNCs via Coulomb forces. A corresponding illustration of the composite synthesis and the final product (appears as a dark blue liquid) are shown in Fig. 1b, whereby the synthesis is described in more detail in the Experimental section.
The ATR-FTIR analysis of S-CNCs, PEDOT, and PEDOT:S-CNCs is depicted in Fig. 2a. FTIR spectroscopy confirms changes in the chemical constituent and structure of composite compared to pristine S-CNCs. By observing the FTIR spectra of S-CNCs and the PEDOT:S-CNCs, the broad peak at 3310 cm−1 can be clearly attributed to the presence of O–H stretching vibrations within hydroxyl groups on the cellulose backbone.20,32,33 The bands at 2905 cm−1 are characteristic of the C–H groups of the cellulose chains, and the peak at 1516 cm−1 can be assigned to the CC stretching of the PEDOT backbone. Additionally, the peaks at 1311 cm−1 and 1023 cm−1 originate from C–C stretching and C–O–C vibrations, respectively, whereby both functional motives can be found within the pyranose rings as well as the PEDOT chain.32,34 The peaks at 891 cm−1 can be identified as C–S bonds of the thiophene ring of PEDOT, which can be found in both the pristine PEDOT and the PEDOT:S-CNCs composite.35,36
The elemental distribution of the composite was obtained from XPS spectra of the biocomposite (Fig. 2b–d). XPS confirmed the presence of the C, O, N, and S elements in PEDOT:S-CNCs samples. The characteristic C 1s core level peaks of PEDOT are C–S (284.7 eV) in the α position, CC–O (286.2 eV) in the β-position and C–O–C (287.1 eV) bonding in the ethylene bridge (Fig. 2c), in a good agreement with the values reported in the literature.37
The S 2p XPS spectra of PEDOT:S-CNCs further confirmed the content of S element (Fig. 2d). The contribution peaks S 2p correspond to sulfur atoms of the PEDOT at 161.8 and 163 eV. Peaks between 165 and 167 eV at higher binding energies are attributed to S-CNCs due to the electronegative oxygen atom attached to the electropositive sulfur atom in the S-CNCs sulfate moiety.21 A complete elemental analysis with the calculation of C, O, and S ratios can be found in the (ESI†), Table S2. We did not observe any residual Fe2+ ions from the oxidant after the polymerization of EDOT (Fig. S2, ESI†).
Raman spectroscopy was recorded to examine the conformational changes of the PEDOT chains in PEDOT:S-CNCs and pristine PEDOT films. The spectra in the 350–1600 cm−1 range are shown in ESI,† Fig. S3a. The bands at 1252 cm−1, 1364 cm−1, and 1414 cm−1 (1410 cm−1 in PEDOT:S-CNCs) correspond to the Cα–Cα, Cβ–Cβ, and symmetric CαCβ stretching vibrations, respectively for PEDOT.38 The peaks at 438 cm−1, 575 cm−1, and 988 cm−1 are associated with the deformation of the oxyethylene ring.38 The strong band at 1400–1470 cm−1 is assigned to CαCβ symmetric stretching on the five-member thiophene ring of PEDOT. In PEDOT:S-CNCs, the peak position of the symmetric stretching vibrations red-shifted from 1414 to 1410 cm−1 and became narrower (ESI,† Fig. S3b). The phenomenon is consistent with the literature and indicates the structural change in PEDOT chains from a benzoid to a quinoid structure in the PEDOT:S-CNCs biocomposite, with respect to pristine PEDOT.39,40 The systematic downshift (4 cm−1) has also been observed by Howikawa et al. for sulfated cellulose-doped PEDOT, and referred to a more extended quinoid formation.40
The presence of the characteristic bands both on FTIR and Raman for PEDOT:S-CNCs suggests that the successful oxidative polymerization in cellulose batches drastically affects the final physical–chemical properties of the composite.
Fig. 3a, c and d show the image of a thin-film of S-CNCs prepared from its dilute suspensions. Field emission scanning electron microscopy (FE-SEM) was employed to investigate the size distribution of CNCs, deposited on glass from a 1 mg L−1 dispersion in DMSO (micrograph in Fig. 3a). In this image, the S-CNCs were detected with high magnification (120000×). They can be observed as individual nanocrystals with a rod-like shape with a diameter of ∼10 nm and 151 ± 15 nm length with similar dimensions that have been reported in the literature.41 The particles had a low aspect ratio (length/diameter) at around 15 ± 1.5 nm. SEM shows particle assemblies: small clusters (i) or large groups of oriented S-CNCs (ii). Random arrangement (i) is noted at low concentrations of nanorods. As the number of particles increases, crystals are densely packed in the same direction to form micro-length fibrous bundles (ii). The nanocrystals aggregate mostly laterally, however, there is also longitudinal aggregation.42 The alignment of the nanocrystals can be attributed to the intermolecular interactions due to sulfate and hydroxyl groups on the nanocrystal surface during drying process of the specimen.
Fig. 3 FE-SEM micrographs (120000×) (a) of the pristine S-CNCs30 and (b) the PEDOT:S-CNCs composite. Scale bar 200 nm. Atomic force microscopy (AFM) images of (c) and (d) pristine S-CNCs and (e) the PEDOT:S-CNCs composite (thickness = 250 nm), and (f) PEDOT:PSS (thickness = 260 nm). The photographs of composites thin-films on the right side of the respective AFM images. |
The transparent films of cellulose nanocrystals were deposited on mica substrates from aqueous suspensions as a specimen for AFM and on glass for optical microscopy. AFM results indicate the state of aggregation as separated nanocrystal domains with regions where there are no nanocrystals. As seen in Fig. 3c, the nanocrystals are smaller (i) than the features recorded by AFM. The data confirms that the images correlate with agglomerated nanocrystals, which are coarser-diameter and micronbundles (ii), as seen in SEM.
Polarized light microscopy (PLM) provides good insight into optical anisotropy or birefringence. The morphology was monitored via optical microscopy by using a polarized-light source and a representative image is shown in ESI,† Fig. S4. The optical response reveals birefringent S-CNCs film corresponding to micron-sized randomly distributed individual crystallites resulting from the self-organization of cellulose nanocrystals. The sample demonstrates a similar blue appearance of CNCs in solid film, which has been correlated to the anisotropic phase after the removal of residual water.43 PLC shows consistency with the indication of the self-assembly behavior of CNCs in dried film. The detailed structure and orientation of the aggregations were visualized by AFM at higher magnification with scan size at the nanometer level. As seen in small aggregates, particles interact with each other to create coarser-diameter fibers. The sharp edge of the micro-bundles can be recognized in Fig. 3d. Additionally, the image also proves longitudinal aggregation, i.e. between the edges of the nanorods.42
Fig. 3b depicts the FE-SEM micrograph of PEDOT:S-CNCs composite material. The film morphology is significantly different than pristine S-CNCs. Notably, the cationic PEDOT polymer was deposited on the surface of charged S-CNCs, resulting in a continuous-like phase as an indication of template synthesis. The polymer preferentially grows around the negatively charged cellulose, leading to PEDOT-coated CNC nanorods, as previously reported.44 The nanocomposite has an amorphous granular structure with nanometer size. Intensive polymerization is observed in some parts of the nanocomposite (middle), while some S-CNC crystals can be observed within the polymer matrix (bottom left). The morphology has a complex composition featuring a two-phase structure allocated to PEDOT- and S-CNC-rich regions. The two-phase morphology is also a well-known phenomenon for PEDOT:PSS in dry polymer film due to synthesis and post-treatment45,46 Additionally, the degree of microstructural heterogeneity can provide a pathway for overcoming hole-limited doping.47,48 PEDOT:PSS has shown efficient transport, indicating homogenous energy landscape for holes despite microstructural heterogeneity.48
In Fig. 3e, the AFM image of PEDOT:S-CNCs reveals a phase separation structure as islands of bright-regions as was reported for PEDOT:PSS.46 The morphology with globular domains can be correlated to the formation of phase separation with PEDOT-rich regions (bright color) and CNC-rich regions (dark color). The phase separation induces enlarged sizes of phase domains for the new composite, with relatively uniform distribution. The surface height image of PEDOT:PSS shows a smooth surface with small islands that are isolated from each other in Fig. 3f. The root-mean-square (RMS) roughness of PEDOT:S-CNCs (40 nm) is higher than PEDOT:PSS (∼4 nm) indicating that the surface of reference is smoother. The photographs of semi-transparent thin-films for each composite are depicted on the right-hand side of the corresponding AFM images.
The synthesized biocomposite's applicability in electronic devices was assessed by using PEDOT:S-CNCs as the channel material in organic electrochemical transistors (OECTs). Usually, adjusting the channel length and width is challenging and requires complex fabrication methods. Traditional lithography is widely employed to fabricate planar OECTs with a channel length down to tens of microns.1–4 To avoid the time-consuming photolithography technique with multi-steps, source and drain electrodes were thermally evaporated through a hard shadow mask, which was designed to shorten the channel length. In this work, OECTs were fabricated by using the device configuration shown in Fig. 4. Additionally, two different source–drain structures were applied, namely a single pair of electrodes and an interdigitated electrode structure with 10 consecutive electrode pairs, as schematically depicted in Fig. 4a and b, respectively. In comparison to our previous work, we have successfully improved the amplitude of the device signal by optimizing the channel geometry.11
The transfer characteristics (IDvs. VG) of PEDOT:S-CNCs are depicted for both source–drain structures in Fig. 5a and b. Additionally, the calculated transconductance (gm = ∂ID/∂VG) is shown next to the respective transfer curve. By increasing gate voltage (VG) to positive values, cations are transferred from the electrolyte into the PEDOT layer, which is consequently de-doped, leading to a state of low to zero conductivity.49 The change in conductivity can be observed with a decrease in drain current (ID) for each electrode architecture. The devices operated in depletion mode represent the p-type MIEC behavior of the channel materials.50 For both device types, the OECT device can be switched “off” by increasing VG to 0.6 V. When comparing the two different electrode structures, the transconductance of an exemplary (with an average device performance) single-channel PEDOT:S-CNCs device exhibits a maximum transconductance (gmax) of 2.39 mS with an on/off ratio of ∼56, whereby an interdigitated device with similar film thickness reaches a gmax of 3.82 mS and an on/off ratio ∼78. Overall, the transconductance values and on/off ratios for the interdigitated channel OECTs are increased by a factor of 1.5 with respect to the single-channel ones. Fig. 5b and d exhibit the output characteristics (IDvs. VD) of PEDOT:S-CNCs devices at applied constant gate voltages. Drain current increases linearly with increased drain voltage (VD), and this consistency in output curves is visible for both device architectures. Once the channel is fully depleted, ID reaches its saturation at VD values of approx. −0.7 V.
The gmax, the figure of merit of OECT, strongly depends on the channel geometry and is directly proportional to WdL−1 (gmax ∝ WdL−1) in which d refers to channel thickness. In order to enhance the device performance, we further optimized the channel thickness by consecutively depositing multiple layers of the biocomposite, as stated in the experimental section. The thickness of the channel film was conveniently controlled by solution processing to form films with thicknesses in the order of 1–3 μm. The transfer (IDvs. VG) and output characteristics (IDvs. VD) of PEDOT:S-CNCs transistor with the active layer thickness of approx. 2 μm are depicted in Fig. 6a–d. Remarkably, the thick-film samples for both single and interdigitated channel geometries validate the improved gmax values of 13.6 mS and 44.3 mS, respectively. Additionally, these devices have almost identical on/off ratios 83 and 84 for the single channel and interdigitated OECTs, respectively. Since PEDOT:PSS is the most commonly used channel material in bioelectronics studies and it was chosen as the standard reference MIEC for comparison. A similar trend in multiplying transconductance was observed for the reference devices. As depicted in ESI,† Fig. S5, the transconductance value was improved from 27.30 to 56.19 mS when switching from single-electrode pair to interdigitated OECTs. After optimization of device channel parameters, the maximum transconductance values up to 44.3 mS was obtained for PEDOT:S-CNCs which was comparable to ∼56 mS for PEDOT:PSS reference transistors. The results reveal the high potential of PEDOT:S-CNCs composite as a channel material for OECTs.
Fig. 6e shows an exemplary depiction of a transfer curve with the corresponding square root of the absolute value of ID. A linear regression is fitted within the steepest part of the transfer curve and consecutively extrapolated to cross the x-axis to determine the threshold voltage (Vth).51 To evaluate and summarize all device results with thin-film channels (thickness range between 140–290 nm), the maximum transconductance of PEDOT:S-CNCs and PEDOT:PSS single-channel OECTs are plotted versus the respective channel geometry and biasing conditions in Fig. 6f. The data obtained for the reference PEDOT:PSS devices are consistent with previously published results by Inal et al.1Table 1 shows a summary of the most relevant device results obtained for the different channel materials, channel geometry and thickness. The data for the exemplary devices having an average device performance is extracted from Fig. 5 and 6 and Fig. S5 (ESI†) for better comparison. The study emphasizes that the channel current can be modulated by the material type and channel geometry. Therefore, channel geometry engineering is essential to improve device performance.
Material | Channel geometry | d/nm | g max/mS | On/off ratio |
---|---|---|---|---|
d: channel thickness, gmax: maximum transconductance. | ||||
PEDOT-S-CNC | Single | 262 | 2.39 | 56 |
Interdigitated | 258 | 3.82 | 78 | |
Single | ∼2000 | 13.6 | 83 | |
Interdigitated | ∼2000 | 44.3 | 84 | |
PEDOT:PSS | Single | 260 | 27.3 | 19 |
Interdigitated | 265 | 56.2 | 2 |
In an alternative approach, Tropp et al. investigated the acid-crystalized PEDOT:PSS (ncrys-PEDOT) nanoparticles as conductive fillers for hydrogels to create soft organic biomaterials.52 Moreover, conductive polymer hydrogels performed as electrical bioadhesive interface for potential soft bioelectronics applications.53 Despite recording high conductivities, the residual PSS within ncrys-PEDOT cannot be avoided. In our work, PEDOT:S-CNC nanoparticles demonstrated remarkable conductivity of 5 S cm−1, values larger than lyophilized PEDOT:PSS (4 S cm−1).52 This simple and facile method may overcome the challenges of traditional conductive fillers to stabilize the dispersion of aqueous biomaterial solutions or biomaterial derived hydrogels for biomedical applications.
The integration of biocomposite as a channel material in OECTs was successfully achieved to evidence ionic-to-electron transduction. The maximum transconductance (gmax) values were obtained up to 13.6 mS and 44.3 mS after optimizing the film thicknesses and device parameters for single-channel and interdigitated OECTs, respectively. High transconductance and device signal have been achieved without applying lithography techniques. To the best of our knowledge, sulfated CNC-templated PEDOT composite was tested in electrochemical transistors for the first time. The results were promising for the development of sustainable and eco-friendly bioelectronics.
As a future perspective, these novel biocomposites can be investigated to enhance mechanical strength, electrical conductivity and long-term biocompatibility in bioelectronics. Moreover, further surface functionalization with specific biomolecules can enhance selectivity and sensitivity for biosensing applications.
Purified 18 MΩ ultrapure water was obtained by the Arium® Mini laboratory water system.
Reference PEDOT synthesis was performed by following the same preparation procedure to compare with the PEDOT:S-CNCs composite using spectroscopy techniques. The oxidative chemical polymerization of tosylate doped PEDOT was also performed using only EDOT with iron(III) p-toluene sulfonate as the oxidant in 2.5 molar equiv. Here, no S-CNCs were included. The tosylate (Tos) anion from the oxidant serves as a counter ion and stabilizes the oxidized cationic PEDOT.
X-ray diffraction (XRD) analysis was performed on an X-ray diffraction (XRD) system X'Pert Pro MPD operating in the Bragg–Brentano geometry. The diffractometer was equipped with a copper radiation source (Cu Kα-radiation). The samples were deposited on a zero-background sample holder. The samples were spun at 0.25 Hz. The crystallinity index (CI) of cellulose was calculated from the XRD spectra by the method reported by Segal,31 according to the following equation:
Fourier-transform infrared (FTIR) spectra were recorded utilizing a Bruker Vertex 80 FTIR spectrometer which is equipped with a Bruker Platinum diamond attenuated total reflectance (ATR) unit. The materials were measured after drying.
Raman spectroscopy was conducted using a Bruker MultiRAM FT-Raman spectrometer with an excitation wavelength of 1064 nm in combination with a liquid nitrogen-cooled Ge detector. The spectra were recorded with a resolution of 4 cm−1 and by averaging over 1000 scans. For the sample preparation, aluminum foil stripes were cleaned with acetone and 18 MΩ water in an ultrasonic bath for 15 min each and consequently blow-dried with N2 gas. The Al foil was then attached to a glass slide with double-sided Kapton tape. The PEDOT:S-CNCs dispersion and the pristine PEDOT dispersion was drop-cast onto the substrates and dried.
X-ray photoelectron spectroscopy (XPS) measurements were performed on a Theta Probe XPS-system (Thermofisher, GBR), which features a monochromated Al-Kα X-ray source with an energy of 1486.6 eV. The spot size on the sample surface was 400 μm in diameter.
The hemispherical analyzer was set to a pass energy of 20 eV for the recorded high-resolution (HR) scans at an energy step size of 0.05 eV. The data acquisition and evaluation, as well as the control of the device, are performed via a software package (Avantage) provided by the system manufacturer. For the XPS characterization the original stock dispersions (PEDOT:S-CNCs and PEDOT:PSS) were used without further additives, whereby the dispersions were drop-cast on glass.
In addition to the biocomposite dispersion, a dispersion of pristine CNCs in 18 MΩ water was also prepared for SEM and AFM imaging. Nanocrystals were suspended in water at a concentration of 1 mg L−1 and spin-cast onto a mica substrate for AFM, while samples for SEM and polarized light microscopy were drop-cast from the suspension with the same concentration on glass.
Field emission – scanning electron microscopy (FE-SEM) analyses were conducted using a FEI FEG-Quanta 450 instrument (Field Electron and Ion Company, Hillsboro, OR, USA). S-CNCs were deposited onto glass substrates from their DMSO suspension at a concentration of 1 mg L−1. Prior to analysis, the samples were sputtered with platinum. The length of the cellulose nanocrystals was measured using Image J 1.53e software (National Institutes of Health, USA) on micrographs taken at 120000× magnification. The standard deviation was calculated based on the mean of over 30 measurements. PEDOT:S-CNCs samples were deposited on ITO-coated glass substrate and the surface was sputtered with platinum before the analysis.
AFM images of the PEDOT:S-CNCs and PEDOT:PSS were obtained by using the Bruker Innova atomic force microscope. For the analysis of S-CNCs, the mica substrate laden with nanoparticles was examined using a Veeco Instruments Nanoscope IIIa microscope in tapping mode. For the deposition of samples reported in the Fig. 3c and d, a 1 mg mL−1 suspension of nanocrystals in water was prepared by tip-sonication (10 pulses, duty cycle 0.6, power 20 W) using a Dr Hielscher 400 W tip sonicator. The suspension was diluted to a final concentration of 1 mg L−1. Every dilution was followed by bath sonication for 20 minutes. 100 microliter of the 1 mg L−1 solution was cast on a mica substrate and the drop was dried in air under a fume hood. Imaging was conducted with silicon cantilevers having a typical curvature radius of 10–15 nm, operating at frequencies between 264 and 339 kHz. The topographies were processed using the Nanoscope software. Dimensions of the nanocrystals, specifically length (L) and width (W) were measured using Image J 1.53e software from the National Institutes of Health, USA. Statistical analysis was performed on over 50 rod-shaped nanocrystals.
The polarized light microscope image was recorded by using a Nikon Eclipse LV100 ND microscope with a polarizing light filter.
The conductivity of the thin films was measured using a Signatone four-point probe station in combination with a Keithley 2400 Source Meter.
To complete the devices, a laser-cut polymer well of 3M™ VHB™ Tape (acrylic adhesive with a conformable acrylic foam core) was fixed on the substrates to secure the aqueous electrolyte. For the device characterization, 20 μL of phosphate buffered saline (PBS) solution (50 mM, pH 7.3) was used, and a silver/silver chloride (Ag/AgCl) electrode was employed as a non-polarizable gate electrode. All steady-state current–voltage measurements were performed under ambient conditions using an Agilent model E5273A.
A Bruker Dektak XT profilometer with a stylus force of 2 mg was used to measure the film thickness.
Microscope images for the channel geometries were recorded utilizing a Nikon Eclipse LV100 ND microscope in bright-field mode.
Footnote |
† Electronic supplementary information (ESI) available. See DOI: https://doi.org/10.1039/d4tc03264k |
This journal is © The Royal Society of Chemistry 2024 |