Marvin N.
Pohl‡
abc,
Sebastian
Malerz‡
a,
Florian
Trinter
ad,
Chin
Lee
bc,
Claudia
Kolbeck§
a,
Iain
Wilkinson
e,
Stephan
Thürmer
f,
Daniel M.
Neumark
bc,
Laurent
Nahon
g,
Ivan
Powis
h,
Gerard
Meijer
a,
Bernd
Winter
a and
Uwe
Hergenhahn
*a
aMolecular Physics, Fritz-Haber-Institut der Max-Planck-Gesellschaft, Faradayweg 4-6, 14195 Berlin, Germany. E-mail: hergenhahn@fhi-berlin.mpg.de
bDepartment of Chemistry, University of California, Berkeley, CA 94720, USA
cChemical Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, CA 94720, USA
dInstitut für Kernphysik, Goethe-Universität Franfurt am Main, Max-von-Laue-Straße 1, 60438 Frankfurt am Main, Germany
eDepartment of Locally-Sensitive & Time-Resolved Spectroscopy, Helmholtz-Zentrum Berlin für Materialien und Energie, Hahn-Meitner-Platz 1, 14109 Berlin, Germany
fDepartment of Chemistry, Graduate School of Science, Kyoto University, Kitashirakawa-Oiwakecho, Sakyo-Ku, Kyoto 606-8502, Japan
gSynchrotron SOLEIL, L'Orme des Mersiers, St. Aubin, BP 48, 91192 Gif sur Yvette, France
hSchool of Chemistry, The University of Nottingham, University Park, Nottingham, UK
First published on 18th February 2022
We present an experimental X-ray photoelectron circular dichroism (PECD) study of liquid fenchone at the C 1s edge. A novel setup to enable PECD measurements on a liquid microjet [Malerz et al., Rev. Sci. Instrum., 2022, 93, 015101] was used. For the C 1s line assigned to fenchone's carbonyl carbon, a non-vanishing asymmetry is found in the intensity of photoelectron spectra acquired under a fixed angle in the backward-scattering plane. This experiment paves the way towards an innovative probe of the chirality of organic/biological molecules in aqueous solution.
It is of great appeal that elements of these two techniques are combined in yet another effect that discriminates between different enantiomers of a species, namely photoelectron circular dichroism (PECD). This term designates an asymmetry in the angle-resolved photoelectron (PE) flux after ionization of a sample of chiral molecules with circularly polarized light. The effect requires a suitable geometry of the experiment, as it vanishes in the plane perpendicular to the photon propagation direction (‘dipole plane’). It can be observed as a difference of photoelectron intensity between two measurements, in which either (1) the same sample is probed by left- versus right-handed circularly polarized light, or (2) the same sample is probed by any helicity of the light, and electrons are collected under two different angles, one in the forward and the other in the backward scattering direction, with the two angles being mirror imaged at the dipole plane, or (3) by probing the two different enantiomers of a substance with either helicity, at an angle outside of the dipole plane. Historically, the potential existence of PECD was noted in theoretical papers in the 1970s,7,8 but only abstract model systems were considered, and these works received only minor attention at that time. It was over twenty years later that a dedicated numerical simulation on actual molecules by Ivan Powis suggested that this effect could have an observable magnitude.9 In fact, it was simulated to be significantly greater than that of more conventional chiroptical methods, since PECD is already allowed in the pure electric dipole approximation, in contrast to regular CD.10 Thereafter, the first experimental observations of PECD were reported for valence photoionization,11–13 and about two years later, a systematic experimental and theoretical study of PECD in core-level photoionization of gaseous camphor confirmed its existence and several features of its behaviour, including its general manifestation within a few tens of eV of an ionization threshold, where the generated photoelectrons are sensitive to the subtleties of any local chiral potential.14 Since then, PECD has been studied in the case of one-photon valence and core-level photoionization of gaseous chiral molecules15–17 and has been extended to clusters and nanoparticles.18–20 Furthermore, its investigation has broadened to include multi-photon21–25 and time-dependent26,27 ionization processes. Using charged particle coincidence experiments, the underlying molecular-frame photoelectron angular distributions (PADs) were also measured.28,29 A profound analysis of the symmetry principles underlying the original PECD mechanism and its variants has appeared recently,30 and the mechanism underlying the build-up of the asymmetric emission in one-photon PECD has been investigated from a fundamental viewpoint.31,32
Here, we present experimental results in the framework of single-photon photoionization processes in a liquid. The primary question we aim to answer is whether PECD can be observed from the photoionization of a liquid composed of chiral constituents. Since the existence of PECD in the gas phase does not require any local molecular ordering, from symmetry principles, this may well be the case. On the other hand, we are not aware of any experiments trying to directly address this question, although a first PECD valence-shell study on pseudo-amorphous nanoparticles of the amino-acid serine revealed a reduced but yet non-vanishing PECD.20 Some of the authors therefore have constructed a new setup dedicated to PECD studies on a liquid microjet, as described elsewhere.33 Here, we present a complete feasibility study of actual PECD detection using a nearly-neat liquid microjet of fenchone. This work opens up the perspective to use this technique for studying the handedness of chiral molecules in aqueous solution, such as amino acids, their building blocks,34 or sugars.35
Fenchone (C10H16O, 1,3,3-trimethylbicyclo[2.2.1]heptan-2-one) is a chiral bicyclic mono-terpenoid built from a six-membered ring with a single-carbon bridge connecting C1 and C4 and featuring three methyl ligands and a carbonyl (CO) group adjacent to one of the asymmetrically substituted chiral centres. Its structure is shown in Fig. 1. The (1R,4S)-(−)-fenchone enantiomer naturally occurs in fennel. Importantly, the CO carbonyl carbon has a 1s core binding energy shift that allows it to be spectroscopically distinguished from the remaining carbon atoms in a core-level photoelectron spectrum (PES).33 Moreover, it has been shown to exhibit a sizeable PECD effect in the gas phase.33,36 Follow-on studies on this molecule also examined PECD effects in its valence PES,37,38 and subsequently targeted multi-photon PECD processes21,23,39,40 and complex electronic-structure dynamics using ultrafast laser pulses.26,41 The choice of fenchone for these prototypical studies has been partially motivated by the relative rigidity of its geometric structure, making conformational isomerism a lesser complication in the interpretation of any associated results, in comparison to those from other similarly-sized chiral systems. In this work, we will address single-photon C 1s core-level PES of fenchone in its native, liquid form, as this presents a clear-cut case for the demonstration of liquid-phase PECD. A small subset of the data from this project was already used for illustrative purposes in an apparatus paper that some of the authors have recently published.33
The photon-energy scale of the monochromator was calibrated by a standard procedure that optimizes the pitch angle for specular reflection. We estimate the residual error after this procedure as ±0.2 eV in the photon-energy range used in this work.
Circularly polarized radiation of either helicity was produced by shifting the magnet blocks of the APPLE-II undulator accordingly. In a separate experiment, the polarization of the ensuing radiation has been analyzed by measuring the PADs of various gases in the plane perpendicular to the light propagation direction.46,47 Measurements were performed for both signs of the undulator geometric shift, corresponding to both output radiation helicities. The shift was varied in small steps in the spectral region of interest, preferentially yielding circularly polarized light. Then the Stokes parameter for circular polarization was calculated as the complement to the Stokes parameters for the residual amount of linear polarization. Experiments were carried out with the 400 l mm−1, 15 nm groove depth grating and yielded absolute values for the circular Stokes parameter, S3, larger than 0.98 for photon energies between 550 and 1250 eV, and in an interval of values of the undulator shift about 5 mm wide. The photon energies of interest in this work are somewhat lower, however, namely in the vicinity of the carbon K-edges of fenchone, slightly below 300 eV. In this energy region, some degradation of the purity of circular polarization has been observed in experiments on another APPLE-II undulator beamline, and was attributed to carbon contamination of the optical elements.48 In any case, on that occasion |S3| was still found to be >0.92. Despite the lack of direct measurements for our setup, we consider it fair to assume similar or lesser circular polarization degradation here. Correspondingly, no further normalization of the measured PECD magnitude has been applied.
By carrying out a PECD measurement on the fenchone gaseous phase evaporating from the liquid jet, we established a correspondence of the geometric shift with negative sign to left-handed circularly polarized light (l-CPL), according to the ‘optical’ convention.33,36,49
The slit restricting the entrance into the hemispheres was set to 800 μm, adapted to the size of the skimmer opening. Electron spectra were measured with a pass energy of 20 eV, and electrons were detected by a stack of two microchannel plates and a fluorescence screen, read out by a CCD camera. The so-called ADC (analog-to-digital conversion) mode of the control software was used, in which the gray-scale camera image is interpreted to yield the underlying electron detection rates.
Spectra were acquired in swept mode. In order to minimize loss of acquisition time by shifting the undulator structure and switching the X-ray beam helicity, spectral sweeps were typically repeated ten to thirty times for each photon helicity, and several pairs of spectra were acquired for both helicities at each photon energy. A set of individual sweeps that were averaged to produce a spectrum are shown in Fig. S1 of the ESI.† Some amount of sweep-to-sweep variation is seen, concerning both intensities and peak energies. The typical extent and time-scale of intensity fluctuations is further illustrated by Fig. S2 and S3 of the ESI.† While the exact origin of these effects is still under investigation, the occurrence of small variations of the jet position (much smaller than the focus size, that is on a length scale of one–two μm) likely contributes significantly to these observations. Before analysing the intensity difference between l,r-CPL, the raw data were checked for sweep-to-sweep variations of intensity or KE, and sweeps identified as clear outliers were removed. Intensities were always determined from sweep-averaged spectra, to make up for the fact that a different amount of sweeps may pass the quality criterion for l- vs. r-CPL. Between 3–30% of sweeps were dropped. In some cases, small KE drifts over the course of data acquisition (50 meV or less) were numerically corrected. Methods for peak-area determination and peak-to-background separation were an essential part of the data analysis and will be detailed below.
No discernible features can be attributed to gas-phase contributions to the spectrum. This is unusual compared to photoelectron spectra of other substances probed in liquid microjet experiments, most notably water,52 but also, e.g., methanol,53 acetic-acid solutions,54 and liquid ammonia.55 In principle, two explanations are conceivable: The gas-phase contributions are too low in intensity to become apparent, or they overlap—in this case—with the features stemming from the liquid phase. The vapour pressure of fenchone in the temperature range relevant for this experiment is 0.33 mbar at 10 °C, more than a factor of ten lower than that of liquid water.56 Typical gas-phase contributions in O 1s spectra of liquid water with the EASI setup at beamline P04 amount to 5–20% of the signal in the O 1s liquid core level peak, depending on the conditions. Hence, a small gas-phase contribution to the fenchone spectra can be expected. In our previous work, we deduced an upper limit for the gas-phase contribution of 14%, based on spectra recorded with a small negative bias applied to the jet in order to separate the gas- and liquid-phase features.33 From the same analysis, we concluded that gas- and liquid-phase C 1s features indeed energetically overlap in the current case. This is a rather non-trivial result, as even in the valence spectrum of liquid fenchone (unpublished data from our own work), or of other non-polar, liquid solvents,57,58 ionization energies are typically lower in the liquid in comparison to the gas phase. In a crude manner, the gas-liquid shift was rationalized by considering the Born free energy of solvation of a positive charge (the vacancy created by photoionization) in the bulk liquid, described by its polarizability, ε, at optical frequencies.59 The quantity ε, taken as the square of the refractive index, does not differ qualitatively between fenchone and liquid water.60 Therefore, we suggest that the small or vanishing gas-liquid shift for the inner-shell levels of fenchone is coincidental; it may result from a cancellation of various factors, e.g., electronic charge redistribution following ionization versus electronic structure changes due to nuclear rearrangement. In this study, we additionally append the previously-determined gas-phase binding energies of 292.6 eV (CO site) and 290.3 eV (CH site) to the analogous liquid phase peaks.36
In addition to the C 1s main lines, an unstructured background of low-KE electrons can be seen (low KE tail, LET). This phenomenon is well known from photoemission studies on bulk solid samples61 and has recently been described in detail for a liquid water jet by some of the authors.51 Briefly, in our study on aqueous solutions, an intense LET was found, atop of which no discernible structures could be resolved in electron spectra below kinetic energies of approximately 10 eV. This is a general result, valid not only for emission out of water's orbitals, but also for features resulting, e.g., from electronic levels of solutes.51 While its exact nature is not fully understood at this moment, it is attributed to a strong increase of the importance of quasi-elastic, e.g., vibrational scattering channels, particularly at electron kinetic energies for which electron-impact ionization channels are closed. Adding to that is an influence of excitation into neutral resonant states lying above the nominal ionization potential.51
Strictly speaking, the nature of the LET and the phenomenon of diminishing peak intensities may very well be of a different nature in fenchone, e.g., less or more intense and with a different energetic threshold, since in liquids little is known about the LET dependence on the ionized substance. Fig. 1 suggests that peak features are observable with acceptable spectral distortion down to KEs of 8 eV in liquid fenchone, which is similar or slightly lower compared to water. This result is of great importance for our work, as in gas-phase studies it has been learned that PECD only leads to significant asymmetries in the threshold region, i.e., at photoelectron kinetic energies below 20 eV. Notably, a comparison of the results on low-KE electron emission from liquid water in ref. 51, giving a lower KE bound at which liquid-phase photoemission peaks from aqueous solutions are discernible, with the gas-phase data by Ulrich et al.,36 giving an upper KE bound at which PECD is still sizeable, suggests that the energy window shown in Fig. 1 spans a range offering good prospects for the identification of PECD in a liquid.
We now turn to an analysis of the differences in photoemission spectra recorded with different helicities of the ionizing photons. Conceptually, we will distill an intensity asymmetry due to PECD from pairs of spectra recorded in the energy range shown in Fig. 1 by taking the following three steps: (1) peak-to-background separation and background subtraction, (2) calculation of the asymmetry from a pair of spectra at equal KE, and (3) correction of this raw value for any apparatus asymmetry.
As the first step, quantifying the amount of background present underneath the two C 1s peaks turned out to be the most problematic as obviously the C 1s signal is outweighed by the background contribution. Modelling it by an analytic procedure recommended for UPS (ultraviolet photoelectron spectroscopy) data62 did not yield a satisfactory representation. We therefore tested several ad hoc approaches to background subtraction, and compare them in detail below.
An exemplary background-corrected pair of sweep-averaged spectra of (1S,4R)-fenchone measured at 301 eV with l- and r-CPL is shown in Fig. 2, for all three background models used. Before we detail the various background-subtraction methods further, we would like to discuss dichroic properties of these two spectra and our approach to apparatus asymmetry correction.
Fig. 2 Background-corrected photoemission spectra of (1S,4R)-(+)-fenchone measured at 301 eV with l- and r-CPL. Panels (A) to (C) show the results of various models by which to subtract the background contribution from a pair of spectra; spectra in Fig. 1 were instead displayed as measured for l-CPL. Background contributions were calculated by (A) fitting an exponential function to the high kinetic end of the spectrum, and subtracting an additional linear background (‘roi’-approach); or (B) by fitting a linear combination of an exponential and a linear function to the high- and low-KE ends of the spectra (‘exp’-approach). For (C), an exponential function has been fitted and subtracted from the raw data. Then, the ‘total background’ function62 is applied to the remaining spectrum (‘sum’-approach). Blue points in panel (A) indicate the experimental asymmetries, Acorr(130°) (plotted versus the left y-axis) for the peaks originating from CO and C–H K-edge photoionization, obtained as the difference divided by two times the mean of r- and l-CPL (eqn (2)), together with associated error bars. The areas marked with dashed lines in panels (B) and (C) indicate the width of the CO peak, which is used for the asymmetry calculations. Expanded (×4) views of these peaks are drawn above the full spectra to get a clearer view on the magnitudes of the l–r asymmetry. |
In panel (A) of Fig. 2, we show a pair of spectra, averaged over two equally long sets of sweeps for each helicity after deletion of outlier traces and correction of (small) energy drifts. A visible apparatus asymmetry due to a small mismatch in photon intensities produced by the undulator in its two opposite settings has been corrected for in the figure as detailed below. The deviation of the intensity ratio from unity by this effect is practically invariant over the narrow photon-energy interval targeted in this paper, and is constant over a measurement campaign. Uncorrected spectra are shown in Fig. S4 of the ESI;† the intensity mismatch can also be seen in the general trend of the per-sweep total intensities in Fig. S2 of the ESI.† In order to correct for this apparatus-induced effect, we have used the helicity-dependent intensity of the C–H peaks in the spectra as an internal light-intensity monitor. This follows a practice from gas-phase studies of PECD in several terpenoids featuring a single CO double bond, where it was noted that an asymmetry associated with the sum of overlapping hydrocarbon site signals in the more intense C–H peak can reasonably be assumed to cancel out.14 It was therefore postulated that the asymmetry of the latter peak vanishes exactly, and the CO asymmetry was correspondingly measured relative to it.14 While this started out as an ad hoc assumption, this tenet was experimentally verified after work on the data-acquisition methodology allowed the measurement of gas-phase PECD free from a baseline error.36,48 We have, therefore, determined the asymmetry of the C–H peak as explained below. For the purpose of illustration, we have used this information to normalize the pair of traces shown in Fig. 2 such that they correspond to the outcome of a measurement that is free from apparatus-induced asymmetry. Here and in the following we use the ratio
(1) |
(2) |
(3) |
In that terminology, panel (A) of Fig. 2 shows the traces Lγ and R. An exponential function fitted only to the part of the spectrum at higher KE than the C–H main line has also been subtracted from the data.
An intensity difference in the traces corrected for apparatus asymmetry, shown in Fig. 2A, can be seen in the region of the CO C 1s line at a KE of ∼8.5 eV. In order to exclusively analyse the intensity that can be attributed to C 1s photoemission, we have subtracted a further, linear background, as indicated by the dashed lines. Within the main C 1s peaks, we have then calculated the corrected asymmetry Acorr,i for every KE channel i. The resulting values are shown in Fig. 2A, plotted against the left-hand axis in a blue color. The error bars were derived as follows: We arranged all sweeps made with l- and with r-CPL into pairs. Labelling the pairs with the index k, we then calculated the distribution Acorr,ik, and give the standard deviation of its mean as an error to the data point Acorr,i. More details of the data processing steps are provided in ESI† Section 1.3 and Supplementary Fig. S4 and S5 (ESI†).
Trivially, channel-wise asymmetries Acorr,i are equal or very near to zero in the range of the major C–H peak (showing the consistency of the baseline correction). Whether the rising trend of the asymmetry data pointing from slightly negative to slightly positive values in going towards smaller KEs is significant cannot be definitively ascertained at this moment. A word of caution is needed about its interpretation, as minute differences in the peak profile as a function of KE may occur e.g. due to small pointing differences for the left-handed versus right-handed undulator radiation, and can readily produce the apparent trend. On the contrary, asymmetry values for the CO peak clearly show an asymmetry which is significantly different from zero. Still, with the current data and uncertainty limits, we refrain from (over-)interpreting the trend of the CO asymmetry data across the low-KE C 1s peak.
As explained above, an exponential background was subtracted in Fig. 2A. Subsequently, peak areas were determined as integrated counts between the range marked with the vertical dashed lines, minus a linear background as indicated by the approximately horizontal dashed lines. Using the term ‘region of interest’ for these ranges, we term this the ‘roi’ method.
The spectra in Panel (B) were constructed by selectively fitting a linear combination of an exponential and a linear function to the data points containing the LET contribution only, specifically at the low- and high-KE ends of the spectra. After subtraction of the estimated background, the spectra were normalized to the C–H peak maximum. Asymmetries have then been calculated from the integrated PE intensities in a 1.4 eV energy range around the CO peak, as indicated by the areas enclosed by the dashed lines in Panel (B) of Fig. 2. We use the label ‘exp’ for this method.
The approach adopted to produce Panel (C) follows a similar procedure to that used to produce Panel (B), with the difference that the background was constructed by first fitting an exponential function to the high-KE side of the spectra and then applying the ‘total background’ function62 (also known as non-iterative Shirley method63) in order to estimate the LET background. This procedure iterates from the high- to the low-KE end of the spectra while aggregating (‘summing’) spectral intensity and is thus referred to as ‘sum’-approach.
More detail on the various background-signal separation methods is provided in the ESI.†
(4) |
(5) |
In our case, a rigorous determination of b1 from our experiment would require a separate measurement of β, which however was outside the scope of this work. In the following, we will therefore estimate the potential influence of the deviation of our setup from the magic-angle geometry. Similarly, an estimate of the potential influence of non-complete circular polarization is in order. Inserting the limiting values of β (−1 and +2) into [1 − (β/2)P2(cosθ)]−1, we find that this factor may range from 0.94 to 1.14 for our θ = 130° detection geometry. In the few works on the angular distribution parameter in photoemission from liquids, however, a trend towards small absolute β values has been found at low kinetic energies.66 Given the results of that study on the O 1s orbital of water, a β ∼ 0.5 might be a plausible but conservative estimate for our case of C 1s emission, which would lead to a factor of 1.03, resulting from the denominator in eqn (5).
Further, consideration of polarization impurities requires a look at the full angular-distribution function, which can be written as:
(6) |
To summarize this discussion, we find that optical polarimetry at the carbon edge, to determine the on-target radiation state, and a photoelectron angular-distribution measurement on liquid fenchone would be desirable for a quantitatively accurate determination of the b1-parameter in our experiment. However, for the moment we will retain the simple relation, b+11 = Acorr/cosθ, and will make an appropriate adjustment to the error bar with respect to the influence of β and any residual non-circular soft X-ray beam polarization.
Fig. 3 The corrected asymmetry, Acorr, and the resulting chiral angular-distribution parameter b+11 as a function of photon energy. We use black symbols for the (1S,4R)- and colored symbols for the (1R,4S)-enantiomer. For the latter, the results from three data sets, acquired in two different measurement campaigns, are shown to indicate the stability of our experiment. Different approaches to subtract the LET and, possibly, a residual background are differentiated by the symbol shape, with diamonds referring to the ‘total background’ approach (Fig. 2C, ‘sum’), circles to the linear-exponential approach (Fig. 2B, ‘exp’) and triangles to the region-of-interest (‘roi’) approach (Fig. 2A). To guide the eye we indicate the averaged values detailed in Table 1 by dashed lines. Values in the figure are not corrected for any possible gas-phase contributions and angular-anisotropy effects (see Table 1). |
301 eV | 302 eV | 303 eV | 304 eV | 305 eV | 307 eV | |
---|---|---|---|---|---|---|
Measured | ||||||
(1R,4S)-Fenchone | 0.023(11) | 0.017(5) | 0.014(7) | — | 0.014(6) | 0.014(5) |
(1S,4R)-Fenchone | −0.017(6) | −0.015(7) | — | −0.011(2) | — | — |
Corrected | ||||||
(1R,4S)-Fenchone | 0.014(12) | 0.010(5) | 0.010(7) | — | 0.011(6) | 0.012(6) |
(1S,4R)-Fenchone | −0.008(6) | −0.009(7) | — | −0.008(2) | — | — |
If we scrutinize the data points in Fig. 3, we find that they neither group by analysis method nor by data set. We therefore believe that the scatter between points does not result from a systematic effect leading to preferentially higher or lower asymmetry values as a function of time or associated with peak-background separation method. In order to arrive at consolidated values, we performed a simple average over all data points for the same photon energy and enantiomer. The results are compiled in Table 1. The scatter in our data points, perceived as coming from fluctuations in the signal and background of the spectra rather than from the data treatment, is represented by the standard deviation of the individual data points leading to each table entry. In the table, we also include two potentially important b+11 corrections, namely one for the presence of gaseous components in the C 1s spectra and another for the potential influence of a non-zero β-parameter, which would affect the connection between the measured anisotropy and b1 values (eqn (5)). As explained above, although no visible presence of a gaseous component has been observed in the PECD measurements, a separate experiment with an electrically biased jet, albeit at slightly different conditions, suggested that this might result from an inconvenient overlap of liquid-phase and gas-phase C 1s peak features.33 Referring to that work, we estimate a gas-phase fraction g between negligible, which is expected from the low vapour pressure of fenchone, and g = 0.14, which is the finding of the aforementioned biased jet experiment. As the gas-phase contribution has a b1-parameter of larger magnitude, correction for the gas-phase contribution would reduce the liquid phase parameter bp1,l according to:
(7) |
We note two further effects that we cannot quantify at this moment, but could be present to some extent. The exact enantiomeric excess (ee) of the samples supplied was not specified and we were unable to have this independently checked, but previous reports have found commercial samples of (1R,4S)-(−)-fenchone to have a lower ee than (1S,4R)-(+)-fenchone samples. In principle, the measured PECD asymmetry should scale linearly with ee values but these are unknown. However, such adjustments are here expected to be within the current error bars, and so have not been applied. The same applies to a correction for an unpolarized fraction of radiation at our sample, which could be slightly increased at the photon energies used in this experiment because of an influence of carbon contamination on the beamline optics. If present, both factors would lead to a correction of the values of b1 extracted from the measured asymmetry towards larger absolute values.
Footnotes |
† Electronic supplementary information (ESI) available: Raw data, further details on peak-background separation. See DOI: 10.1039/d1cp05748k |
‡ These authors contributed equally to this work. |
§ Current address: sonUtec GmbH, Mittlere-Motsch-Straße 26, 96515 Sonneberg, Germany. |
This journal is © the Owner Societies 2022 |