Qi He,
Zipei Zhu,
Hao Dong and
Kaijun Xiao*
School of Food Science and Engineering, South China University of Technology, Guangzhou City, Guangdong Province, China 510640. E-mail: fekjxiao@scut.edu.cn; Tel: +86 20 87113843
First published on 26th July 2017
Ag-based nano-graft is a common approach used to impart broad-spectrum antimicrobial activity to a polymer membrane. The primary problem with this approach is low compatibility between the grafted particles and the polymer main-body, followed by its low anti-adhesion for undesired membrane fouling. To overcome these problems, this study functionalized polyethersulfone (PES) materials by a sulfonation process to form the membrane backbone. FTIR, thermogravimetry (TG) and contact angle (CA) analysis showed that sulfonate treatment improved hydrophilicity and surface activity. Accordingly, the Ag-based nano-grafts were embedded on the membrane by immersing into a Ag+ solution and then reducing. The resulting membrane was characterized by a series of assays. SEM and AFM scans were used to examine the membrane surface for Ag nanoparticles (AgNPs) distribution. XRD and XPS analysis determined the AgNPs state. A concentration assay revealed that the Ag release from the membrane was maintained within the safety range during the filtration process. An antimicrobial ring test showed the antimicrobial activities of the membrane for different microbial strains. BET analysis and the water-absorption test analyzed the porosity properties of the membrane. The filtration performance assay proved that the membrane had remarkable interception ability for various solutes. Consequently, it showed that the prepared SPES-AgNPs membrane will have a promising application as an antimicrobial filtration membrane for water treatment.
During the filtration process, biofouling is the most undesired problem. It can greatly impact membrane performance and is manifested by declining flux, increased energy cost and shortened lifetime.3,4 Due to the special attached structure on microorganism cells, biofouling can hardly be cleaned.5,6 Even worse, because of the microorganisms' self-replicating nature, biofouling will be enhanced geometrically during membrane use.7
The available strategies to solve this problem are mainly “anti-adhesion” or “antimicrobial”.8 On one hand, hydrophilic surfaces are much less likely to attach to bacteria, but most industrial polymeric membrane materials are hydrophobic.9 Therefore, an effective anti-adhesion approach is to improve hydrophilicity of the polymer materials. On the other hand, a common approach for the “antimicrobial” strategy is to directly incorporate some biocides into the membrane.10 A suitable antimicrobial compound is needed to balance antimicrobial activity and toxicity towards humans. Thus, AgNPs are of special interest as an antimicrobial additive.11,12 Moreover, due to the advantages of easy handling, high solubility in organic solvents and outstanding chemical resistance, PES is considered as a hopeful material to form the membrane backbone.13 Reportedly, the recent PES-Ag based products still have several defects including low hydrophilicity, low graft amount, high Ag release and short-lived antimicrobial activity.14,15 Therefore, to solve these problems, this study initiates the introduction of –SO3H into the PES backbone. As a result, the prepared SPES-AgNPs membrane exhibits outstanding hydrophilicity and antimicrobial activities to reduce membrane fouling. It also shows some improvements in porosities and the ions' interception ability.
The ion exchange capacity (IEC) of the prepared SPES material was determined through the H+ release amount. SPES material was minced into pieces with a size of several millimeters. The minced material was suspended in 2 M of NaCl solution (0.5 g SPES per 50 mL NaCl) for 24 h and titrated using a NaOH solution (0.1 M) with phenolphthalein as the indicator. The IEC was calculated by eqn (1):17
(1) |
Accordingly, the degree of sulfonation (DS) of the prepared SPES material was determined by eqn (2):17
(2) |
Fourier transform infrared (FTIR) spectra of the prepared SPES material were investigated using a FTIR analyzer (Vector 33, Bruker Company, Germany); the analysis was carried out in the wavelength range 600–4000 cm.
The thermogravimetric (TG) properties of the prepared SPES material were determined using a TG analyzer (TA Q500, TA Company, US). The temperature range was controlled as 100–700 °C.
The hydrophilicity of the prepared SPES material was estimated using a contact angle (CA) goniometer (OCA15, Dataphysics Company, Germany).18 Three repeats were performed for each membrane.
SPES-AgNPs membranes were prepared by loading AgNPs on the SPES membrane. The resulting membrane was immersed in 2.5 g L−1 of AgNO3 aqueous solution for 2 h. The residual solvent on the surface was removed. Then, it was immersed in 0.25 mol L−1 of vitamin C aqueous solution for 15 min. After this, the membrane was washed using deionized water and air-dried at ∼21 °C for 24 h. In addition, a PES-AgNPs membrane was prepared using a similar method as the control sample.19
The surface topologies of the prepared membranes were characterized using atomic force microscopy (AFM, Multimode 8, Bruker Company, Germany). In order to reduce errors, the roughness was reported as an average value.21
Ag release was monitored by measuring its concentration in a filtration test. Each membrane (100 cm2) was used in a water filtration process with a flux of ∼100 L m−2 h−1 at room temperature (∼20 °C). Every 2 h, a water sample was obtained from the permeate side and the Ag concentration in this sample was analyzed using an atomic absorption spectrometer (AAS, Z-2000, Hitachi, Japan).23
The antimicrobial activities of the prepared membranes were assessed using two Gram-negative bacteria (E. coli and P. aeruginosa) and a Gram-positive bacterium (S. aureus). Each membrane was cut as a small disk (1 cm of diameter) and placed on a nutrient agar that had been inoculated with different microbial strains. The resulting agars were incubated for 24 h at 37 °C. Then, the colonies obtained on the agar were counted. Three replicates were performed for each measurement.24
A further study was performed via bacterial suspensions. Some disks of each membrane (about 0.5 g) were immersed into 10 mL of different bacterial suspensions (108 CFU mL−1) and cultured in a table concentrator with suitable shaking at 37 °C for 2 h. Then, the bacterial suspension was diluted into a suitable concentration with sterile water, inoculated on LB solid medium, and cultured at 37 °C for 24 h. Three replicates were performed for each membrane. The antimicrobial rate was calculated by eqn (3):25
(3) |
The water-absorption porosities (ε) of the prepared membranes were investigated according to the method described by Basri et al.27 A dry membrane was weighed and the weight was recorded as Wdry. Then, it was immersed in distilled water at ∼21 °C and periodically re-weighed until its weight was constant (Wwet). The ε value was calculated by eqn (4):
(4) |
The filtration performance of the prepared membranes was evaluated using a 1 g L−1 bovine serum albumin (BSA) solution (pH = 7.4) and 4 types of 2 w/v% aqueous solutions with inorganic matter (NaCl, Na2SO4, MgCl2 and MgSO4). The initial concentration and the concentration in the permeated liquid were recorded as c0 and c, respectively, for the interception rate (IR) calculation. The concentrations of BSA were measured using an ultraviolet spectrophotometer (UV, D-8PC, Phelps Company, China) at 278 nm, while the concentrations of target salts were measured using AAS. The IR were calculated by eqn (5):28
(5) |
Fig. 1b illustrates the FTIR results. Significant characteristic peaks of –SO3H groups (∼1100 cm−1) were found in the curve of SPES. Another noteworthy characteristic peak was presented at ∼3200 cm−1. It represented the reflection of hydroxyl groups (–OH).11 The presence of –OH was a sign of hydration. It further suggested the remarkable hydrophilicity of SPES.11 Moreover, due to O particles having great electronegativity, the presence of –OH can establish strong links with the loading AgNPs.
The TG results are shown in Fig. 1c. When temperature was less than ∼200 °C, no significant weight loss was found in each material. When the temperature was 200–450 °C, a slight weight loss was presented in the SPES material due to the decomposition of sulfonic acid groups.30 When the temperature increased to 450–600 °C, the PES chain that formed the membrane backbones broke down, and thus both PES and SPES experienced great weight loss (40–60%).
Higher hydrophilicity yielded better wettability that could suppress concentration polarization on the membrane surface. Consequently, it improved membrane resistance for pollution fouling.31 As shown in Fig. 1d, the CA of the PES membrane was 64.3 ± 3.2°. Moreover, the presence of –SO3H enhanced the hydrophilicity of SPES. Thus, the CAs of the SPES membrane was less than 50%. Reportedly, the CAs of common commercial seawater reverse osmosis (RO) membranes were usually limited at the range of 25–60°.32 In this study, the SPES membrane was within this range. This revealed that the prepared SPES membrane was suitable as a RO membrane for water treatment.
The topology of the membrane surface was observed in the AFM results. Among them, the SPES membrane had a relatively smoother surface with a height of 45.3 nm. Moreover, because of the graft of AgNPs on the surface, the height of the SPES-AgNPs and the PES-AgNPs membrane increased to ∼100 nm.
XPS results can also prove a similar conclusion. Reportedly, the Ag0 element has two typical XPS peaks centered at binding energies (BE) 369.4 eV (Ag 3d5/2) and 375.8 eV (Ag 3d3/2).34 As shown in Fig. 3b, corresponding peaks were found at the curve of both the SPES-AgNPs membrane (369.5 eV and 375.8 eV) and the PES-AgNPs membrane (369.1 eV and 375.3 eV). Similarly, the peak intensities of the SPES-AgNPs membrane were significantly stronger than the PES-AgNPs membrane.
In addition, Fig. 3c illustrated the possible formations for the interaction between SPES monomers and grafted AgNPs.27 The Ag0 atoms are prone to the loss of electrons and change into Ag+, while the O atoms (1s2 2s2 2p4) from the SPES material have 2 lone-pairs of electrons that can form a coordination bond with Ag+. Moreover, with the attraction of the S5+ particle in the –SO3 groups, the O atoms from the –SO3 groups more easily attract Ag+ and have stronger links compared to the phenyl oxygen in the main chain.27 Thus, we can infer that the PES-AgNPs membrane more easily loses its grafted Ag+ compared to the SPES-AgNPs membrane. This can be proven by the Ag release results, as shown in Fig. 3d. On both membranes, Ag release showed a gradual decrease, while the downward trend of the SPES-AgNPs membrane was much gentler compared to the PES-AgNPs. Another notable point is that the accumulation of Ag should balance the antimicrobial activity and toxicity towards humans. Based on the safety standards reported by the WHO for drinking water (100 μg L−1),35 the use of the SPES-AgNPs membrane can always remain in a safe range, while the PES-AgNPs membrane was beyond the limitation at the first time. Furthermore, when taking the total Ag content into consideration, the SPES-AgNPs membrane released only 3.35% of its total AgNPs in the first 24 hours, while PES-AgNPs only released 8.58%, indicating that the SPES-AgNPs membrane may have more than double the antimicrobial shelf life of the PES-AgNPs membrane. Fig. 3e described the inhibition zone results. The pure SPES membrane only slightly impacted the bacteria, because –SO3H is a strong oxidizing agent that can kill some microbes. In comparison, SPES-AgNPs and PES-AgNPs membranes showed significant antimicrobial activities. The AgNPs is believed to act as an outstanding antimicrobial agent.36 Its ions diffused away from the membrane and killed microbes in the area along the outer edge of the membrane disks, resulting in a wide inhibiting ring. Such antimicrobial activity was quantized by the results using suspensions (as Fig. 3f). The inhibition using the PES and the SPES membrane was less than 25%, while either the SPES-AgNPs or the PES-AgNPs membrane was more than 80%. When it comes to the difference from different microbial strains, the overall inhibition from strongest to weakest ranked as follows: P. aeruginosa > S. aureus > E. coli.
Fig. 4 (a) BET results; (b) porosity properties; and (c) interception capacity of the prepared membranes. |
During the operating process of a membrane for water treatment, its performance is to a great extent determined by the selective interception capacity for given compounds of organic substances or inorganic salts. Fig. 4c summarizes the performance of the prepared membranes for different substances during the filtration process. As is shown, different prepared membranes displayed remarkable interception capacity. Synthetically, the PES-AgNPs membrane showed the best interception capacity. This could be explained by the fact that the AgNPs blocked some voids that could be available for solute substances.
Membranes | Thickness (μm) | CA (°) | Flux (L m−2 h−1) | BSA rejection (%) | Porosity ε (%) | Mean pore size (nm) | Ref. |
---|---|---|---|---|---|---|---|
NanoAgZ-PES | — | 52.6–71.5 | 82.1–110.6 | 96.1–98.5 | — | — | 8 |
PES | ∼100 | 59.85 | — | — | 0.038 | 10.30 | 12 and 27 |
PES/Ag | ∼100 | 50.97 | — | — | 0.038 | 3.74 | |
PES/PVP/Ag | ∼100 | 47.85 | — | — | 0.203 | 0.92 | |
PES/TAP/Ag | ∼100 | 42.06 | — | — | 0.104 | 1.45 | |
PES-Am-Ag | — | — | ∼120 | ∼60 | — | — | 14 |
Bio-Ag0/PES | ∼140 | 51.4–66.6 | 150–500 | — | — | — | 15 |
SPES-AgNPs | ∼40 | ∼45 | ∼100 | 95.2 | 0.509 | ∼4 | This work |
Moreover, compared to some other studies using a complex additive or modification, our materials were relatively cheap and common, while the preparing process was simple and well developed. Huang et al.8 prepared a nanoAgZ-PES membrane. The prepared membrane had a comparable flux, a similar antimicrobial activity for E. coli and P. aeruginosa and a slightly superior IR for BSA. However, this study used a rare material, nanoAgZ. Sawada et al.14 added an extra acrylamide (CA) layer as the medium between the PES layer and grafted Ag. Its overall performance was slight weaker than our product. Furthermore, the introduction of the CA layer greatly complicated the preparation process, as well as reduced the reliability.
This journal is © The Royal Society of Chemistry 2017 |