Stimuli-directed selective detection of Cu2+ and Cr2O72− ions using a pH-responsive chitosan-poly(aminoamide) fluorescent microgel in aqueous media

Soumen Ghosh , Jyoti Devi Katiyar and Subrata Chattopadhyay *
Department of Chemistry, Indian Institute of Technology Patna, Bihta, Patna 801106, Bihar, India. E-mail: sch@iitp.ac.in

Received 3rd October 2023 , Accepted 11th November 2023

First published on 13th November 2023


Abstract

In this work, the preparation of a pH-responsive fluorescent microgel, (NANO-PAMAM-CHT), is presented for the selective detection of Cu2+ and Cr2O72− ions. The NANO-PAMAM-CHT (nanosized polyaminoamide-chitosan microgel) is synthesized via aza-Michael addition reactions in a controlled and stepwise manner in water, using easily affordable starting materials like 1,4-diaminobutane, N,N′-methylene-bis-acrylamide, NIPAM and chitosan. NANO-PAMAM-CHT shows pH-responsive fluorescent properties, whereas the fluorescence intensity shows a pH-responsive change. Due to the selective fluorescence quenching, the microgel can detect both Cu2+ ions and Cr2O72− ions selectively at ambient pH in aqueous medium. Moreover, it can selectively differentiate between Cu2+ ion and Cr2O72− ions at pH ∼3 in water. The limits of detection for Cu2+ ions and Cr2O72− ions are reported as 16.9 μM and 2.62 μM, respectively (lower than the minimum allowed level in drinking water) at pH ∼7. Mechanistic study further reveals the dynamic quenching phenomenon in the presence of Cu2+ ions and static quenching in the presence of Cr2O72− ions.


Introduction

With the exponential growth of different chemical industries and unethical waste disposal practices, water pollution has emerged as a global issue.1–3 Therefore, simple and affordable detection of toxic components is extremely important and has emerged as a fascinating research area due to their chemical4,5 and biological6,7 applications. In this context, colorimetric and fluorescent sensors have attracted much more attention because of their selectivity, high sensitivity, low cost, and fast response time for the detection of cationic and anionic species.8–11 Without the help of highly expensive instruments like atomic absorption spectroscopy (AAS), and inductively coupled plasma-mass spectrometry (ICP-MS), the fluorescence-sensor based metal ion detection technique is a straightforward and low-cost process and therefore, the development of such sensors has attracted much attention.12,13 In this context, several advanced functional materials such as carbon dots,14,15 quantum dots,16,17 metal ion based fluorophores,18–20 polymers,21–25 small molecular organic probes,26–28 micelles29 and microgels30,31 are reported. In most of the cases, such fluorophores can selectively detect a single ion.19,32 However, this limits its practical applicability to an extent, and therefore recent efforts are going towards the detection of more than one ion selectively using a single fluorescent probe. In this context, a few conjugated hydrophobic organic and polymeric fluorophores are reported which can detect more than one metal ion by varying the solvent systems or the ratio of organic to aqueous mixtures.33–35 Besides, a few metal organic framework-based fluorophores have demonstrated the detection of more than one metal ion; however, most of them suffer from less or no selectivity between the detectable analytes.16,36,37 In addition, metal organic framework-based sensors generally suffer from low water stability and solubility, which limits their practical applicability for detection.38,39 Therefore, stimuli responsive polymer materials, such as microgels can be a better choice due to their smart responsive properties and higher water stability. Examples of fluorescent microgels are already known, which have demonstrated their ability to detect metal ions in aqueous solution.30,40,41 In the majority of these reports, it demonstrated selective detection of single metal ions under ambient temperature and pH. Recently, Dong et al. reported a responsive microgel for the selective detection of Fe3+ and Mn2+ at pH ∼2 and pH ∼12, respectively.30 However, no detection is possible at ambient pH and also the performance is effected by a change of temperature.

Herein, we are aiming to develop a stimuli-responsive fluorescent microgel as a single fluorescent probe, which can sense both Cu2+ ions and Cr2O72− ions selectively in aqueous solution. Both the analytes are marked as priority pollutants by the United States Environmental Protection Agency.42 The third most abundant transition metal in human bodies is Cu2+, among all the transition metal ions. Towards living organisms, Cu2+ becomes a hazardous and toxic element at high concentration.42 Neurodegenerative disorders, such as Alzheimer's disease, Wilson's disease and Menkes disease, are associated with the unregulation of the Cu2+ ion.43 According to the US Environmental Protection Agency (EPA), the limit for copper is 20 μM in drinking water.42 Besides, the dichromate ion (Cr2O72−) is known to be extremely toxic for all living beinga.44 Even at a very low concentration, dichromate can lead to serious health issues, like damage to the mucus membrane, lung cancer, renal damage, pulmonary sensitivity, targeting the respiratory tract and damaging the skin.45 According to the American Water Works Association: Denver, CO, USA, the maximum allowed contaminant level of dichromate ions is 5 μM.46 Therefore, selective detection of these two ions is important.

In the present work, we have designed and developed a stimuli responsive microgel (NANO-PAMAM-CHT) for the selective detection of two different ions in aqueous media with the variation of the pH. The microgel core backbone is comprised of polyaminoamide, a nonconventional hydrophilic fluorescent polymer, which is modified with chitosan to prepare NANO-PAMAM-CHT (nanosized polyaminoamide-chitosan microgel). Chitosan is a biobased polymer, containing amines and hydroxyl groups, which can interact with different metal ions and is therefore useful for metal ion sensing.47 Besides, for the current system, the primary amine groups of chitosan can act as a binding site (Michael-donor) to react with the acrylamide moieties (Michael-acceptor) of NANO-PAMAM. NANO-PAMAM-CHT can selectively detect both Cu2+ and Cr2O72− at ambient pH and temperature. Besides, the pH-responsive property of NANO-PAMAM-CHT further discriminates between the two detected ions (Cu2+ ion from Cr2O72−) at pH 3, where we observed that the presence of Cu2+ ions is unable to quench the fluorescence intensity of NANO-PAMAM-CHT, but the presence of Cr2O72− is selectively able to quench the fluorescence intensity efficiently. Mechanistic study reveals dynamic quenching of NANO-PAMAM-CHT in the presence of Cu2+ ions and static quenching in the presence of Cr2O72− ions. Additionally, time dependent study exhibits a fast response time and a temperature dependent study affirms that the microgel can be used in a wide range of ambient temperatures (25 °C–45 °C), without any impact on its performance.

Results and discussion

Synthesis and characterization

NANO-PAMAM-CHT microgels are prepared via aza-Michael reaction in water, as illustrated in Scheme 1. Initially, as per the established reported protocol by our group,48 NANO-PAMAM is synthesized in a two-step process. The first step involves the preparation of intermediate poly(aminoamide) via reaction between 1,4-diaminobutane and N,N-methylenebisacrylamide, and the second step involves the functionalization of N-isopropylacrylamide to prepare the stable NANO-PAMAM nanogel. In the next stage, the aza-Michael addition reaction between acryl-amide functional groups of NANO-PAMAM and free amine groups of chitosan in water at room temperature leads to the formation of NANO-PAMAM-CHT.
image file: d3sm01319g-s1.tif
Scheme 1 Synthetic scheme for the NANO-PAMAM-CHT microgels and its application towards the selective detection of Cu2+ and Cr2O72− in water.

The reaction conditions were screened with different weight ratios of NANO-PAMAM and chitosan, to optimise the formation of NANO-PAMAM-CHT microgels (Fig. S1, ESI). To analyse the reaction, the disappearance of the prominent peaks for acryl amide protons of NANO-PAMAM at around 5.5–6.5 ppm was monitored by varying the weight ratio of NANO-PAMAM to chitosan (1[thin space (1/6-em)]:[thin space (1/6-em)]1, 1[thin space (1/6-em)]:[thin space (1/6-em)]1.5 and 1[thin space (1/6-em)]:[thin space (1/6-em)]2) in the presence of base, DABCO (Table S1, ESI). At the weight ratio of NANO-PAMAM to chitosan (1[thin space (1/6-em)]:[thin space (1/6-em)]2), we can achieve 100% conversion to the product (NANO-PAMAM-CHT) in the presence of DABCO (as a base). The NANO-PAMAM-CHT microgel was purified via precipitation in acetone and characterized by different techniques. 1H NMR spectra analysis (Fig. 1A) reveals the presence of characteristic peaks of both chitosan and poly(aminoamide) backbone as assigned, with a complete disappearance of (CH2[double bond, length as m-dash]CH–) proton peaks of acrylamides (which are present in NANO-PAMAM). This reveals the formation of NANO-PAMAM-CHT via aza-Michael addition reaction.


image file: d3sm01319g-f1.tif
Fig. 1 (A) 1H-NMR analysis of NANO-PAMAM and NANO-PAMAM-CHT (NANO-PAMAM: CHT = 1[thin space (1/6-em)]:[thin space (1/6-em)]2, wt. ratio). (B) FT-IR spectra analysis of NANO-PAMAM, NANO-PAMAM-CHT and chitosan (CHT).

Furthermore, the formation of the NANO-PAMAM-CHT microgels was affirmed by FTIR spectra (Fig. 1B). In the case of chitosan (CHT), the typical stretching band of the –OH group and –NH2 group appeared at 3400–3322 cm−1. The stretching band of amino (N–H) bending corresponds to the peaks at 1650 cm−1 and 1583 cm−1. For primary alcohol (C–OH) and methylene (CH2) groups, stretching bands are coming at 1022 cm−1 and 1367 cm−1 respectively. For NANO-PAMAM-CHT (NANO-PAMAM modified with the free amine group of chitosan), a C[double bond, length as m-dash]O stretching band appeared at 1642 cm−1 and the disappearance of the IR bands at 2962 cm−1 is for (C[double bond, length as m-dash]C–H). This supports the successful synthesis of NANO-PAMAM-CHT via the aza-Michael addition reaction between the acrylamide group of NANO-PAMAM and the free amine group of chitosan.

Thermogravimetric analysis (TGA) of the NANO-PAMAM-CHT was done from room temperature to 800 °C to reveal the thermal stability and structure (Fig. S2, ESI). From the TGA thermogram, initially ∼10% weight loss was observed around 100 °C, which can be attributed to the moisture present, due to the hygroscopic nature of the microgel backbone. In the second step, the weight loss at around 200 °C, can be primarily attributed to the thermal degradation of the chitosan backbone49 and in the final stage, weight loss at around 280 °C is attributed to the degradation of the poly(aminoamide) backbone of NANO-PAMAM-CHT, in addition to the ongoing chitosan backbone.50–52

Size exclusion chromatography (SEC), was used to analyze the average molecular weight of NANO-PAMAM-CHT (Fig. S3, ESI). The average molecular weight of the microgel was in the order of 105 Da.

To understand the size and morphology, the microgels were analyzed using DLS, AFM and TEM. For a better understanding, NANO-PAMAM and NANO-PAMAM-CHT are compared through all the analyses. The average hydrodynamic diameter of the NANO-PAMAM increases from ∼60 nm to ∼200 nm (Fig. 2A) after modification with chitosan (NANO-PAMAM-CHT). Fig. 2B exhibits the transmission electron microgram of NANO-PAMAM, where we have seen that the size of the NANO-PAMAM lies in the range of around 40 nm to 60 nm. Whereas, in Fig. 2C, we observed that the size of NANO-PAMAM-CHT increases to 150 nm to 250 nm. Additionally, the AFM analysis of NANO-PAMAM-CHT revealed the presence of irregular microstructures that were also evident from the 3D structure of NANO-PAMAM-CHT as shown in Fig. S4B (ESI) and the diameter of NANO-PAMAM-CHT lies in the range of 150–200 nm (Fig. S4A, ESI). From the height profile graph of NANO-PAMAM-CHT, we can conclude that the microgel was flattened and spread over the substrate surface due to its soft nature (Fig. S4A, ESI).


image file: d3sm01319g-f2.tif
Fig. 2 (A) DLS of NANO-PAMAM and NANO-PAMAM-CHT. (B) TEM micrograph of NANO-PAMAM and (C) TEM micrograph of NANO-PAMAM-CHT (after reacting with chitosan).

pH responsive optical properties of the NANO-PAMAM-CHT

NANO-PAMAM-CHT was excited at 370 nm to analyse the blue emission property (as observed under UV light) where the spectra reveal λmax = 440 nm (Fig. 3A). The fluorescence property of NANO-PAMAM-CHT is attributed largely to the nonconventional fluorescent polyaminoamide core (NANO-PAMAM). Compared with the NANO-PAMAM, the λmax of the NANO-PAMAM-CHT microgel is slightly red-shifted (∼27 nm) and a hyper-chromic shift was noted (likely the effect of chitosan). The CIE 1931 color coordinate diagram confirms the blue emission of NANO-PAMAM-CHT, where the (X, Y) coordinates are (0.16, 0.14), as shown in Fig. S5, ESI.
image file: d3sm01319g-f3.tif
Fig. 3 (A) Fluorescence emission spectra of NANO-PAMAM and NANO-PAMAM-CHT (inset: the picture of NANO-PAMAM-CHT solution under UV light). (B) Variation of the fluorescence intensity as a function of different pH.

To further understand the influence of pH, the emission spectra of NANO-PAMAM-CHT were studied in a range of pHs by using a spectrofluorometer (Fig. S6, ESI). Fig. 3B exhibits the variation of fluorescence intensity with changing the pH – a significant increment in fluorescence intensity was noted as the pH of the solution rises from pH 3 to pH 11. A probable hypothesis behind this is that, at the higher/basic pH, amine groups are deprotonated, which results in an increase in the formation of localized clusters due to more favourable intramolecular interactions, resulting in an increase in fluorescence intensity.53

Sensing of different metal ions

A fluorescence screening experiment was performed at ambient pH (pH ∼7) to observe the selectivity of the synthesized NANO-PAMAM-CHT microgel toward different ions. Two sets of experiments were performed for the screening of both cations and anions. Fig. 4A exhibits the emission spectra of photoluminescence activity for NANO-PAMAM-CHT with the addition of Cu2+, Zn2+, Ca2+, Mn2+, Fe2+, Fe3+, Cr3+, Ba2+, Mg2+, Ni2+, Co2+, Pb2+, Cd2+, Na+, and K+ metal ion solutions (10 mM). The selectivity was measured by plotting I/I0 (intensity ratio) with the same concentration of different metal ion solutions, where I and I0 indicate the photoluminescence intensity of the microgel solution (with excitation at 370 nm) in the presence of different metal ions and in the absence of any metal ions, respectively. The obtained histogram (Fig. 4B) reveals that in the presence of Cu2+, the I/I0 ratio significantly decreased compared to the other metal ions. This signifies that the NANO-PAMAM-CHT exhibits selective turn off behaviour in the presence of Cu2+ solutions. With interference from other metal ions, the sensing and selectivity are vulnerable in the chemical detector. Using various metal ions, we performed competitive experiments (Fig. S7, ESI) to authenticate the selectivity of NANO-PAMAM-CHT towards Cu2+ ions. The fluorescence intensities of NANO-PAMAM-CHT were not reduced significantly in the presence of various metal ions but the fluorescence intensities decreased significantly on further addition of Cu2+ ions (Fig. S8, ESI). Hence, this result infers that without interference from other metal ions, NANO-PAMAM-CHT selectively detects Cu2+ ions. From these results, we can conclude that NANO-PAMAM-CHT ensured recognizable advantages in detecting copper ions.
image file: d3sm01319g-f4.tif
Fig. 4 (A) Fluorescence emission spectra of NANO-PAMAM-CHT in the presence of different metal ions with excitation at 370 nm. (B) Selectivity of NANO-PAMAM-CHT towards Cu2+ ions. (C) Fluorescence emission spectra of NANO-PAMAM-CHT in the presence of different anions with excitation at 370 nm. (D) Selectivity of NANO-PAMAM-CHT towards Cr2O72− ions.

Similarly, to study the selectivity for different anions, the emission spectra of NANO-PAMAM-CHT were measured in the presence of different anions, using NaX solution, where X = HAsO42−, IO3, N3, F, SO42−, HCO3, Cl, CN and Cr2O72−. From the fluorescence spectra analysis (Fig. 4C), we observed that the fluorescence intensity of NANO-PAMAM-CHT in the presence of HAsO42−, IO3, N3, F, SO42−, HCO3, Cl, and CN did not change significantly but the same is selectively decreased in the presence of Cr2O72−. Similar analysis of I/I0 (intensity ratio) with the same concentration of different anionic analytes reveals significant and selective turn off for Cr2O72− (Fig. 4D). This indicates that NANO-PAMAM-CHT microgels can act as a probe for the selective detection of Cr2O72− ions.

To understand the interference of other anions on NANO-PAMAM-CHT, we carried out a competitive experiment in the presence of Cr2O72− ions with other anions like HAsO42−, IO3, N3, F, SO42−, CN, HCO3 and Cl (Fig. S9, ESI). The incorporation of equivalent molar interfering anions HAsO42−, IO3, N3, F, SO42−, CN, HCO3 and Cl into the aqueous solution of NANO-PAMAM-CHT at pH 7 did not affect its fluorescence intensity but the fluorescence intensities decreased significantly on further addition of Cr2O72− ions (Fig. S10, ESI). Hence, this result concludes that without interference from other anions, NANO-PAMAM-CHT selectively detects Cr2O72− ions.

The Stern–Volmer equation was used for the analysis of the quenching effect quantitatively for both Cu2+ ions and Cr2O72− ions and the equation is expressed as:

I0/I = 1 + KSV[Q]
where I0 is the fluorescence intensity before the addition of analytes and I is the fluorescence intensity after the addition of analytes, KSV is known as the Stern–Volmer constant, and [Q] is the analyte concentration. In the range from 0–25 μM, a consistent decrease in fluorescence intensity was observed with increasing concentration of Cu2+ ions (Fig. 5A). A good linear relationship was observed by plotting the relative intensity (I0/I) against increasing concentration of copper solution, where the value of correlation coefficient (R2) was 0.999 and KSV = 2722.24 M−1, as presented in Fig. 5B. The calculated limit of detection (LOD) was 16.9 μM (Fig. S11, ESI) using the equation LOD = 3δ/k, where δ is standard deviation and k is the slope obtained from the intensity vs. concentration plot. It is important to note that the LOD is lower compared to the allowed limit of Cu2+ in drinking water as approved by the US Environmental Protection Agency (EPA).42


image file: d3sm01319g-f5.tif
Fig. 5 (A) Quenching of the fluorescence intensity of NANO-PAMAM-CHT by aqueous solution of Cu2+ ions under excitation at 370 nm with slit 2. (B) Stern–Volmer plot for NANO-PAMAM-CHT by Cu2+ solution; the inset picture shows the Ksv plot at the lower concentration region in the presence of Cu2+ ions. (C) Quenching of the fluorescence intensity of NANO-PAMAM-CHT by an aqueous solution of Cr2O72− ions under excitation at 370 nm with slit 2. (D) Stern–Volmer plot for NANO-PAMAM-CHT by Cr2O72− solution; the inset picture shows the Ksv plot at the lower concentration region in the presence of Cr2O72−ions.

Similarly for dichromate anion, the fluorescence intensity of NANO-PAMAM-CHT was studied within the analyte concentration range of 0.00–36 μM (Fig. 5C), and a linear correlation coefficient (R2) of 0.996 and a KSV value of 22[thin space (1/6-em)]180 M−1 was reported as calculated using the Stern–Volmer equation (Fig. 5D). From the fluorescence emission intensity of NANO-PAMAM-CHT, the high Ksv value indicates the relatively high quenching efficiency for Cr2O72−.

The limit of detection (LOD) of Cr2O72− was calculated as 2.62 μM (Fig. S12, ESI). Herein, it is important to note that the LOD is lower compared to the allowed level of dichromate contamination in drinking water according to the American Water Works Association: Denver, CO, USA (5 μM).46 A comparison was studied for NANO-PAMAM-CHT with the other sensors in the presence of Cu2+ and Cr2O72− and tabulated in Tables S2 and S3 (ESI), respectively. A time-dependent quenching study was done in the presence of Cu2+ ions and Cr2O72− ions, respectively (Fig. S13 and S14, ESI). Fig. S15 (ESI) reveals that NANO-PAMAM-CHT can detect both analytes within a minute, signifying fast response time for the demonstrated detections. Additionally, we have studied the temperature-dependent fluorescence behaviour of NANO-PAMAM-CHT at 25 °C and at 45 °C in the presence of both Cu2+ ions and Cr2O72− ions (Fig. S16–S19, ESI). It was noted that the fluorescence intensity ratio (I0/I) of NANO-PAMAM-CHT was not affected by increasing temperature; this reveals that the microgels are useful in various temperature and climate regions, without changing their efficiency.

pH-dependent discrimination of Cu2+ and Cr2O72−

As both Cu2+ and Cr2O72− were detected by a turn off mechanism, it is further important to differentiate between them for highly specific sensing. For that purpose, a pH responsive study was conducted for both the analytes at lower pH (acidic, pH ∼3). NANO-PAMAM-CHT consists of hyper-branched polyaminoamide and chitosan moieties, and contains protonable –NH2 groups. It is expected that due to higher protonation of amine with the NANO-PAMAM-CHT, interactions with Cu2+ will be restricted at lower pH. From Fig. 6A and B, it was observed that the original fluorescence intensity of NANO-PAMAM-CHT was not significantly reduced at pH 3 in the presence of Cu2+ ions. On the other hand, the presence of Cr2O72− ions significantly quenched the fluorescence intensity of NANO-PAMAM-CHT. A plot summarizing the concentration dependent study within the range between 0–690 μM clearly revealed a clear decrease in fluorescence intensity in the presence of Cr2O72− (Fig. 6D), whereas absolutely no change in the presence of Cu2+ ions was noted (Fig. 6C). This confirms that NANO-PAMAM-CHT can selectively detect Cr2O72−, in the presence of Cu2+ at pH ∼3. From the plot, a correlation coefficient (R2) = 0.987 and KSV = 14[thin space (1/6-em)]149 M−1 (inset picture of Fig. 6D) was reported for Cr2O72− at pH ∼3. The calculated limit of detection (LOD) for Cr2O72− at pH ∼3 was 8.08 μM (Fig. S20, ESI). Further studies were continued to understand the performance of NANO-PAMAM-CHT towards sensing of both Cu2+ and Cr2O72− under basic pH (pH ∼9). It was noted that the microgel can sense both the analytes without any discrimination (unlike pH ∼3). The limit of detection (LOD) of both Cr2O72− (Fig. S21, ESI) and Cu2+ (Fig. S22, ESI) was calculated as 3.1 μM and 31 μM respectively at pH ∼9.
image file: d3sm01319g-f6.tif
Fig. 6 (A) and (B) Fluorescence emission spectra of NANO-PAMAM-CHT in the presence of Cu2+ and Cr2O72− at pH 3. (C) and (D) Ksv plot of NANO-PAMAM-CHT with the addition of Cu2+ and Cr2O72− at pH 3. (E) and (F) Quenching efficiency plot of NANO-PAMAM-CHT with the addition of Cu2+ and Cr2O72− at pH 3.

Mechanism of sensing

Fluorescence quenching can occur mainly due to three reasons, (i) fluorescent materials transferred into non-fluorescent materials, (ii) electron transfer, and (iii) the inner filter effect.54 For the quenching incident, different mechanisms are generally known, such as dynamic quenching, static quenching, and competitive absorption. Static quenching may happen due to the formation of the ground state complex/interactions. On the other hand, dynamic quenching involves the process of collision in the excited state. To get more information about the dynamic and static mechanisms, the time-correlated single photon counting (TCSPC) technique was carried out.30 A clear decrease in the average lifetime (obtained using the decay parameter in Table S4, ESI) of the NANO-PAMAM-CHT was identified from 5.48 ns to 4.89 ns in the absence and presence of Cu2+ ions in the aqueous solution of NANO-PAMAM-CHT, which supported the dynamic quenching process in the presence of Cu2+ ions (Fig. 7A). After the addition of Cr2O72− solution into the aqueous solution of NANO-PAMAM-CHT, no such noticeable variation of average lifetime (using decay parameters in Table S5, ESI) was observed. Hence, a static quenching process may be involved in the quenching phenomenon of NANO-PAMAM-CHT in the presence of Cr2O72− ions (Fig. 7B). To further affirm this, UV-vis spectra of aqueous solutions of NANO-PAMAM-CHT (Fig. 7C) in the presence of dichromate ion were recorded. The absorption peak originating at around 370 nm supported the ground state interaction between NANO-PAMAM-CHT and Cr2O72− ions (Fig. 7C). Besides, compared with pure dichromate solution, the absorption peak was significantly red shifted (20 nm) compared to the absorption peak of pure dichromate (Fig. S23, ESI). Hence, combination of both the studies supported the static quenching phenomenon of NANO-PAMAM-CHT in the presence of Cr2O72− ions.55 On the other hand, with the addition of Cu2+ ions, we did not observe such a shift of the absorption peak.
image file: d3sm01319g-f7.tif
Fig. 7 (A) Fluorescence decay with excitation at 375 nm for NANO-PAMAM-CHT in the absence and presence of Cu2+ ions by using the time-correlated single photon counting (TCSPC) technique. (B) Fluorescence decay with excitation at 375 nm for NANO-PAMAM-CHT in the absence and presence of Cr2O72− ions by using the time-correlated single photon counting (TCSPC) technique. (C) UV-vis absorption spectra of NANO-PAMAM-CHT with the addition of Cr2O72− and Cu2+ ions.

Conclusion

In summary, the synthesis of a water-soluble pH responsive fluorescent microgel (NANO-PAMAM-CHT) is reported via aza-Michael addition reaction between an acrylamide functional aminoamide (NANO-PAMAM) and chitosan in water at room temperature. The reaction was monitored via NMR spectroscopy and the final microgel was further characterized by IR, SEC, TGA, DLS, TEM and AFM. This microgel can show a pH responsive fluorescent property from pH 3 to pH 11. A detailed study reveals that the microgel can selectively detect Cu2+ and Cr2O72− ions in water under ambient pH within a minute and their calculated limits of detection are 16.9 μM and 2.62 μM, respectively (both are below than minimum allowed level). Moreover, it can selectively differentiate between Cu2+ and Cr2O72− at pH ∼3, where selective quenching is only noted for Cr2O72− in aqueous media. The mechanistic study supported by the fluorescence decay and the UV-vis spectra analysis, further supported the existence of a dynamic quenching phenomenon in the presence of Cu2+ and static quenching in the presence of Cr2O72. Moreover, time and temperature-dependent studies revealed a fast response time (within a minute) and its efficient usefulness in a wide range of temperatures.

Author contributions

S. G. performed all the experiments and analysis. J. D. K. performed the reaction between NANO-PAMAM and chitosan. S. C. supervised the work and received the funding.

Conflicts of interest

There are no conflicts to declare.

Acknowledgements

S. G. and J. D. K. acknowledge IITP for the research fellowship and SC acknowledges CSIR (02(0370)/19/EMRII) for funding the work.

Notes and references

  1. M. R. Awual, I. M. M. Rahman, T. Yaita, M. A. Khaleque and M. Ferdows, Chem. Eng. J., 2014, 236, 100–109 CrossRef CAS.
  2. Z. Ö. Kocabaş-Ataklı and Y. Yürüm, Chem. Eng. J., 2013, 225, 625–635 CrossRef.
  3. A. H. Sulaymon, B. A. Abid and J. A. Al-Najar, Chem. Eng. J., 2009, 155, 647–653 CrossRef CAS.
  4. N. Choudhury, B. Saha and P. De, Eur. Polym. J., 2021, 145, 110233 CrossRef CAS.
  5. V. Kumar, S. K. Saini, N. Choudhury, A. Kumar, B. Maiti, P. De, M. Kumar and S. Satapathi, ACS Appl. Polym. Mater., 2021, 3, 4017–4026 CrossRef CAS.
  6. K. P. Carter, A. M. Young and A. E. Palmer, Chem. Rev., 2014, 114, 4564–4601 CrossRef CAS.
  7. N. Choudhury, B. Ruidas, C. D. Mukhopadhyay and P. De, ACS Appl. Polym. Mater., 2020, 2, 5077–5085 CrossRef CAS.
  8. X. Chen, M. J. Jou, H. Lee, S. Kou, J. Lim, S.-W. Nam, S. Park, K.-M. Kim and J. Yoon, Sens. Actuators, B, 2009, 137, 597–602 CrossRef CAS.
  9. S. Erdemir, B. Tabakci and M. Tabakci, Sens. Actuators, B, 2016, 228, 109–116 CrossRef CAS.
  10. Z.-H. Liu, S. Devaraj, C.-R. Yang and Y.-P. Yen, Sens. Actuators, B, 2012, 174, 555–562 CrossRef CAS.
  11. Q. Wu, X. Wang, S. A. Rasaki, T. Thomas, C. Wang, C. Zhang and M. Yang, J. Mater. Chem. C, 2018, 6, 4508–4515 RSC.
  12. N. Gogoi, M. Barooah, G. Majumdar and D. Chowdhury, ACS Appl. Mater. Interfaces, 2015, 7, 3058–3067 CrossRef CAS.
  13. A. Jaiswal, S. S. Ghsoh and A. Chattopadhyay, Langmuir, 2012, 28, 15687–15696 CrossRef CAS PubMed.
  14. T. Boobalan, M. Sethupathi, N. Sengottuvelan, P. Kumar, P. Balaji, B. Gulyás, P. Padmanabhan, S. T. Selvan and A. Arun, ACS Appl. Nano Mater., 2020, 3, 5910–5919 CrossRef CAS.
  15. H. Barhum, T. Alon, M. Attrash, A. Machnev, I. Shishkin and P. Ginzburg, ACS Appl. Nano Mater., 2021, 4, 9919–9931 CrossRef CAS PubMed.
  16. M. M. R. Khan, T. Mitra and D. Sahoo, RSC Adv., 2020, 10, 9512–9524 RSC.
  17. X. Gao, C. Du, Z. Zhuang and W. Chen, J. Mater. Chem. C, 2016, 4, 6927–6945 RSC.
  18. H. Bai, Z. Tu, Y. Liu, Q. Tai, Z. Guo and S. Liu, J. Hazard. Mater., 2020, 386, 121654 CrossRef CAS PubMed.
  19. G. K. Darbha, A. K. Singh, U. S. Rai, E. Yu, H. Yu and P. Chandra Ray, J. Am. Chem. Soc., 2008, 130, 8038–8043 CrossRef CAS.
  20. P. Daga, P. Majee, D. K. Singha, P. Manna, S. Hui, A. K. Ghosh, P. Mahata and S. K. Mondal, New J. Chem., 2020, 44, 4376–4385 RSC.
  21. N. Choudhury, B. Ruidas, B. Saha, K. Srikanth, C. D. Mukhopadhyay and P. De, Polym. Chem., 2020, 11, 2015–2026 RSC.
  22. N. Choudhury, S. Mete, S. Kambalapalli and P. De, J. Polym. Sci., Part A: Polym. Chem., 2018, 56, 914–921 CrossRef CAS.
  23. S. Xiong, L. Duan and X. Cheng, Polym. Chem., 2020, 11, 6066–6072 RSC.
  24. P. M. Reddy, S.-R. Hsieh, W.-C. Wu, C.-J. Chang, Y.-S. Chen and M.-C. Lee, React. Funct. Polym., 2018, 123, 26–33 CrossRef CAS.
  25. S. Xiong, W. Sun, R. Chen, Z. Yuan and X. Cheng, Carbohydr. Polym., 2021, 273, 118590 CrossRef CAS PubMed.
  26. G. Pina-Luis, M. Martínez-Quiroz, A. Ochoa-Terán, H. Santacruz-Ortega and E. Mendez-Valenzuela, J. Lumin., 2013, 134, 729–738 CrossRef CAS.
  27. P. M. Reddy, S.-R. Hsieh, M.-C. Lee, C.-J. Chang, A. Pundi, Y.-S. Chen, C.-H. Lu and J.-M. Yeh, Dyes Pigm., 2019, 164, 327–334 CrossRef CAS.
  28. D. Zhang, Y. Qi, Y. Li, Y. Song, C. Xian, H. Li and P. Cong, J. Fluoresc., 2021, 31, 1133–1141 CrossRef CAS PubMed.
  29. N. Kumari, N. Dey, S. Jha and S. Bhattacharya, ACS Appl. Mater. Interfaces, 2013, 5, 2438–2445 CrossRef CAS PubMed.
  30. S. Dong, W. Ji, Z. Ma, Z. Zhu, N. Ding, J. Nie and B. Du, ACS Appl. Polym. Mater., 2020, 2, 3621–3631 CrossRef CAS.
  31. S. Kumari, M. Avais and S. Chattopadhyay, ACS Appl. Polym. Mater., 2023, 5, 1626–1645 CrossRef CAS.
  32. Q. Miao, Z. Wu, Z. Hai, C. Tao, Q. Yuan, Y. Gong, Y. Guan, J. Jiang and G. Liang, Nanoscale, 2015, 7, 2797–2804 RSC.
  33. M. Dong, Y.-W. Wang and Y. Peng, Org. Lett., 2010, 12, 5310–5313 CrossRef CAS.
  34. Z.-Q. Hu, C.-s Lin, X.-M. Wang, L. Ding, C.-L. Cui, S.-F. Liu and H. Y. Lu, Chem. Commun., 2010, 46, 3765–3767 RSC.
  35. L. Xu, Y. Xu, W. Zhu, B. Zeng, C. Yang, B. Wu and X. Qian, Org. Biomol. Chem., 2011, 9, 8284–8287 RSC.
  36. P. Majee, D. K. Singha, S. K. Mondal and P. Mahata, Photochem. Photobiol. Sci., 2019, 18, 1110–1121 CrossRef CAS.
  37. J. Kaushik, D. Saini, R. Singh, P. Dubey and S. K. Sonkar, New J. Chem., 2021, 45, 20164–20172 RSC.
  38. L. Li, S. Shen, R. Lin, Y. Bai and H. Liu, Chem. Commun., 2017, 53, 9986–9989 RSC.
  39. Y.-Z. Chen and H.-L. Jiang, Chem. Mater., 2016, 28, 6698–6704 CrossRef CAS.
  40. B. Wen, J. Xue, X. Zhou, Q. Wu, J. Nie, J. Xu and B. Du, ACS Appl. Mater. Interfaces, 2018, 10, 25706–25716 CrossRef CAS PubMed.
  41. J. Yin, X. Guan, D. Wang and S. Liu, Langmuir, 2009, 25, 11367–11374 CrossRef CAS PubMed.
  42. L. M. Gaetke, H. S. Chow-Johnson and C. K. Chow, Arch. Toxicol., 2014, 88, 1929–1938 CrossRef CAS PubMed.
  43. C. Zong, K. Ai, G. Zhang, H. Li and L. Lu, Anal. Chem., 2011, 83, 3126–3132 CrossRef CAS PubMed.
  44. Z.-J. Lin, H.-Q. Zheng, H.-Y. Zheng, L.-P. Lin, Q. Xin and R. Cao, Inorg. Chem., 2017, 56, 14178–14188 CrossRef CAS PubMed.
  45. S. Mohandoss, J. Sivakamavalli, B. Vaseeharan and T. Stalin, Sens. Actuators, B, 2016, 234, 300–315 CrossRef CAS.
  46. A. W. W. Association, J. Am. WATER Work. Assoc., 2013 Search PubMed.
  47. S. Lv, S. Liang, J. Zuo and S. Zhang, Analyst, 2022, 147, 4657–4673 RSC.
  48. S. Ghosh, M. Avais and S. Chattopadhyay, Chem. Commun., 2022, 58, 12807–12810 RSC.
  49. J. D. Katiyar and S. Chattopadhyay, Carbohydr. Polym., 2022, 287, 119324 CrossRef CAS PubMed.
  50. M. Avais and S. Chattopadhyay, ACS Appl. Polym. Mater., 2021, 3, 789–800 CrossRef CAS.
  51. M. Avais and S. Chattopadhyay, J. Mater. Chem. A, 2022, 10, 20090–20100 RSC.
  52. M. Avais, S. Kumari and S. Chattopadhyay, Soft Matter, 2021, 17, 6383–6393 RSC.
  53. R.-b Wang, W.-z Yuan and X.-y Zhu, Chin. J. Polym. Sci., 2015, 33, 680–687 CrossRef CAS.
  54. L. Lin, M. Rong, S. Lu, X. Song, Y. Zhong, J. Yan, Y. Wang and X. Chen, Nanoscale, 2015, 7, 1872–1878 RSC.
  55. A. S. Tanwar, R. Parui, R. Garai, M. A. Chanu and P. K. Iyer, ACS Meas. Sci. Au, 2021, 2, 23–30 CrossRef PubMed.

Footnote

Electronic supplementary information (ESI) available. See DOI: https://doi.org/10.1039/d3sm01319g

This journal is © The Royal Society of Chemistry 2024