Farhad
Azarmi
a,
Prashant
Kumar
*ab,
Daniel
Marsh
c and
Gary
Fuller
c
aDepartment of Civil and Environmental Engineering, Faculty of Engineering and Physical Sciences, University of Surrey, Guildford GU2 7XH, UK. E-mail: P.Kumar@surrey.ac.uk; Prashant.Kumar@cantab.net; Fax: +44 (0)1483 682135; Tel: +44 (0)1483 682762
bEnvironmental Flow (EnFlo) Research Centre, Faculty of Engineering and Physical Sciences, University of Surrey, Guildford GU2 7XH, UK
cMRC PHE Centre for Environment and Health, King's College London, London SE1 9NH, UK
First published on 7th December 2015
Construction activities are common across cities; however, the studies assessing their contribution to airborne PM10 (≤10 μm) and PM2.5 (≤2.5 μm) particles on the surrounding air quality are limited. Herein, we assessed the impact of PM10 and PM2.5 arising from construction works in and around London. Measurements were carried out at 17 different monitoring stations around three construction sites between January 2002 and December 2013. Tapered element oscillating microbalance (TEOM 1400) and OSIRIS (2315) particle monitors were used to measure the PM10 and PM2.5 fractions in the 0.1–10 μm size range along with the ambient meteorological data. The data was analysed using bivariate concentration polar plots and k-means clustering techniques. Daily mean concentrations of PM10 were found to exceed the European Union target limit value of 50 μg m−3 at 11 monitoring stations but remained within the allowable 35 exceedences per year, except at two monitoring stations. In general, construction works were found to influence the downwind concentrations of PM10 relatively more than PM2.5. Splitting of the data between working (0800–1800 h; local time) and non-working (1800–0800 h) periods showed about 2.2-fold higher concentrations of PM10 during working hours when compared with non-working hours. However, these observations did not allow to conclude that this increase was from the construction site emissions. Together, the polar concentration plots and the k-means cluster analysis applied to a pair of monitoring stations across the construction sites (i.e. one in upwind and the other in downwind) confirmed the contribution of construction sources on the measured concentrations. Furthermore, pairing the monitoring stations downwind of the construction sites showed a logarithmic decrease (with R2 about 0.9) in the PM10 and PM2.5 concentration with distance. Our findings clearly indicate an impact of construction activities on the nearby downwind areas and a need for developing mitigation measures to limit their escape from the construction sites.
Environmental impactConstruction activities have potential to increase the local concentrations of coarse and fine particles, which adversely affect public health. Increased construction activities are expected to cope with the growing world population, which highlights the importance of particle emissions from these sources. This study assesses the impact of PM10 (≤10 μm) and PM2.5 (≤2.5 μm) arising from outdoor construction works on the surrounding environment in London. Increased concentrations at monitoring stations downwind of the construction sites suggest a need to develop efficient mitigation strategies to limit the escape of particulate matter from construction sites. |
Activity type | Pollutant type | Characteristics | Reference |
---|---|---|---|
Building and road works | PM10 | Outdoor (at over 80 monitoring sites in and around London, UK) | Fuller and Green13 |
Building implosion | PM10 | Outdoor (22-story building in east Baltimore, USA) | Beck et al.32 |
Building demolition | PM10 | Outdoor (three public housing developments in Chicago, USA) | Dorevitch et al.33 |
Building demolition | PM10 | Outdoor (demolition of an old four-story building on the premises of the University Hospital of Essen, Germany) | Hansen et al.31 |
Construction activities | PM10 | Outdoor (construction and operational activities at a port in Mumbai, India) | Joseph et al.34 |
Earthmoving activities | PM10 and PM2.5 | Outdoor (earth moving activities conducted at two Kansas sites, Kansas city, USA) | Muleski et al.36 |
Road widening and construction activities | PM10 and PM2.5 | Outdoor (road widening and related construction works in London, UK) | Font et al.57 |
Besides construction activities, PM10 concentrations are also affected by the emissions arising from local fugitive sources such as road works,11–15 vehicle exhaust16–20 and non-vehicle exhaust sources.21–26 At the same time, many activities associated with air and sea transportation produce particles across the range of PM10 and PM2.5.27–29 A few studies have investigated the PM10 emissions arising from industrial sources such as waste transfer stations.30 There are also a few studies concerned with PM10 emissions arising from outdoor construction activities.31–35 However, there is still very little work focused on PM2.5 fractions arising from construction activities.36
The importance of particle exposure from construction sources is expected to increase with the ever growing world population.37,38 In addition to concerns associated with the short-term exposure to airborne PM at the time of construction activities, there is also the potential for long-term exposure to PM that settles across the nearby community, which is then available for inhalation or ingestion after resuspension.32,39,40
The European Union41 set the targets to limit the daily and annual mean values of PM10 at a European-wide level for the years 2004 and 2010.13 The legal limit by 2005 was to achieve a daily mean PM10 concentration of 50 μg m−3, not exceeded on more than 35 occasions per year and annual mean values of 40 μg m−3. Moreover, the target by 2010 was to achieve a daily mean PM10 concentration of 50 μg m−3, not exceeded on more than 7 occasions per year and annual mean concentrations of 20 μg m−3. These target values, to be met by 2010, were not carried forward in Directive 2008/50/EC.42 Fuller and Green13 noted that the PM10 emissions generated by building and road works in and around London breached the EU limits for the daily mean PM10 concentrations (50 μg m−3) on several occasions. In this study, a series of PM10 and PM2.5 measurements at 17 monitoring stations around construction sites were carried out during 2002–2013 to assess their impact on the air quality in the surrounding areas.
Fig. 1 Schematic of the experimental set-up showing the monitoring stations (MS) and construction sites (CS). Please note that the figure is not to scale and the distances are presented in Table 2. |
Site code | Duration | Species monitored | Instrument used | Location (distance of the MS from CS) |
---|---|---|---|---|
MS1 | January 2002–January 2007 | PM10 | TEOM 1400 | CS1 (3000 m) |
MS2 | January 2002–January 2007 | PM10 | TEOM 1400 | CS1 (500 m) |
MS3 | January 2002–January 2007 | PM10 | TEOM 1400 | CS1 (500 m) |
MS4 | January 2002–January 2007 | PM10, PM2.5 | TEOM 1400 | CS1 (100 m) |
MS5 | January 2002–January 2007 | PM10, PM2.5 | TEOM 1400 | CS1 (200 m) |
MS6 | January 2002–January 2007 | PM10, PM2.5 | TEOM 1400 | CS1 (200 m) |
MS7 | January 2002–January 2007 | PM10, PM2.5 | TEOM 1400 | CS1 (500 m) |
MS8 | January 2002–January 2007 | PM10, PM2.5 | TEOM 1400 | CS1 (500 m) |
MS9 | January 2002–January 2007 | PM10, PM2.5 | TEOM 1400 | CS1 (4000 m) |
MS10 | January 2009–December 2013 | PM10 | OSIRIS 2315 | CS2 (100 m) |
MS11 | December 2009–May 2013 | PM10 | OSIRIS 2315 | CS2 (200 m) |
MS12 | November 2008–December 2013 | PM10 | OSIRIS 2315 | CS2 (1000 m) |
MS13 | January 2009–December 2013 | PM10 | OSIRIS 2315 | CS2 (3000 m) |
MS14 | May 2013–December 2013 | PM10 | OSIRIS 2315 | CS2 (100 m) |
MS15 | January 2009–October 2014 | PM10 | OSIRIS 2315 | CS2 (400 m) |
MS16 | June 2011–August 2012 | PM10 | OSIRIS 2315 | CS3 (100 m) |
MS17 | June 2011–August 2012 | PM10 | OSIRIS 2315 | CS3 (50 m) |
Data were analysed with reference to the EU Limit Values for annual and daily PM10 concentrations. In addition, bivariate plots were drawn to qualitatively assess the effects of wind speed and direction on the measured concentrations in upwind and downwind directions from construction sites. The k-means clustering technique was then applied to assess contribution of probable local construction sources, which were identified through bivariate polar plots of paired monitoring stations (i.e. one in upwind and the other in downwind). The k-means clustering technique helped to identify the range of increases in particle mass concentrations due to the construction operations, including the resuspension and emissions from any on-site vehicles.43 Moreover, the frequency and variation in PM10 and PM2.5 concentration in the prevailing wind direction were evaluated with changes in distance from sources by pairing the sites in downwind of the CS1–CS3 to assess the decay profile of the PM emissions, which is important to understand the impact of the construction works on the air quality in surrounding areas.
The TEOM 1400 was used to measure mass of particles per unit volume of air in the size range of 0.1–10 μm. The sampling stream and filters were heated to 50 °C to maintain a stable temperature and to eliminate interference from water on the filter.44 The mass measurement relied on the measurement of the resonant frequency of an oscillating system that consists of the filter and glass element. A correction factor of 1.3 was recommended in the UK for comparison of PM10 measurements from TEOM with the EU Directive 1999/30/EC13,41 prior to the development of a dynamic correction system45,46 and was applied in this study. Further details about the working principle and sensitivity of the TEOM 1400 can be found elsewhere.47–49
The Turnkey Osiris instrument (model 2315) was used to measure the mass distribution of particles per unit volume of air in the 0.4–20 μm size range by light scattering technology in a mass concentration range of 0.1–6000 μg m−3.50 The Osiris instrument is a portable device that is capable of sampling and measuring particle concentrations in real-time with a high temporal resolution (1 s minimum). The air sample is continuously drawn into the instrument by a pump with a flow rate set by the microprocessor at a rate of 0.6 l min−1 through an inlet heated to 50 °C to minimise the effects of water droplets and particle bound water. Over 20000 particles per second can be sized before coincidence effects occur. Several size selective inlets are also available for the instrument. These can be used to collect a size selected gravimetric sample on the instrument's filter and will measure in μg m−3. The Osiris instrument also allows wind speed and direction, temperature and relative humidity to be recorded at the same time. The Turnkey Instruments, OSIRIS monitors, have also been used for the assessment of indoor and outdoor PM levels as well as personal exposure in a number of past studies.51,52
Meteorological data was produced taking a mean from a number of different monitoring locations across the monitoring stations and construction areas wherein the meteorological equipment is considered to be working well and the data shows a good correlation. The measurements were carried out using cup anemometers and wind vanes (as opposed to sonic anemometers) mainly made by Campbell Scientific. This equipment was located at a height of about 10 m.
Closer inspection of polar plots at all 17 monitoring stations around each of the three sites indicates the following: first, whenever there are monitoring stations in the downwind side of the construction sites, high concentrations of PM10 (Fig. 2) and PM2.5 (Fig. 3) are observed, indicating a potential contribution from the construction activities (Fig. 2). Second, pockets of high PM concentrations can also be observed in some cases (for example, observe MS2 for PM10 and MS9 for PM2.5 in Fig. 2a and 3, respectively) despite the monitoring stations being in the upwind of the east and south-west wind directions. This was expected due to long-range transport of PM10 during easterly winds from European countries54,55 and the effect of generated sea salt on PM2.5 from the south-westerly winds.55,56 This observation also suggests that the concentrations measured downwind of the construction sites include some contribution of emissions from these sources and are not solely from the emissions of the construction activities. However, this analysis was inadequate to conclusively report that the measured downwind emissions are from the construction sites. Therefore, paired-site (Section 3.2) and k-means (Section 3.3) analyses were performed to better understand the contributions of the construction emissions during varying wind directions.
Fig. 5 and 6 show the contribution of each cluster in the polar plots of ΔPM10 and ΔPM2.5. The temporal variation of ΔPM10 and ΔPM2.5 contributed by each cluster on an hourly, weekly and monthly basis are also shown. Based on the ΔPM10 and ΔPM2.5 concentrations showing the high concentration peaks in the polar plots (Fig. 4), clusters 5–7 can be identified to represent the concentrations of ΔPM10 (Fig. 5) and ΔPM2.5 (Fig. 6) due to construction sources. If we observe these clusters in the temporal variation plots, peaks can be observed during the weekdays, which are missing during the weekends. This is also demonstrated by the increases in the PM10 and PM2.5 concentrations during 08:00 and 18:00 h, which we referred to as “working hours”. The temporal plots on a monthly basis were examined and the identified clusters (i.e. 5–7) showed relatively lower concentrations during the cold months (i.e. December, January and February) compared with the rest of the months. There could be two possible reasons for these lower concentrations: (i) less construction activity compared to normal and (ii) the weather conditions suppressing the emissions and transport of particles due to relatively wetter conditions than the other months and also affecting the normal construction due to adverse weather conditions. For example, the mean precipitation and relative humidity is expected to be higher during winter months (e.g. 256 mm and 85% to 213 mm and 70% during summer) and low temperature (e.g. mean ∼4 °C to 15 °C during summer).61 Past studies have found wet conditions such as water spraying an effective method to suppress coarse particle emissions by up to 13-times during construction works.62 Detailed receptor modelling studies could help further in drawing firm conclusions.
Fig. 7 The annual average concentrations of PM10 (17 monitoring stations) during the 2002–2013 period at (a) CS1, (b) CS2, and (c) CS3. |
Year | Monitoring stations | ||||||||
---|---|---|---|---|---|---|---|---|---|
MS1 | MS2 | MS3 | MS4 | MS5 | MS6 | MS7 | MS8 | MS9 | |
2002 | — | 21.9 ± 12.2 | 19.1 ± 11.2 | 29.5 ± 22.3 | 27.5 ± 20.9 | 23.6 ± 15.6 | 19.3 ± 10.5 | 19.4 ± 10.2 | 24.3 ± 14.4 |
2003 | — | 24.5 ± 15.7 | 21.2 ± 12.9 | 36.7 ± 32.1 | 26.8 ± 18.6 | 31.3 ± 27.9 | 22.1 ± 14.0 | 23.8 ± 15.5 | 22.1 ± 13.7 |
2004 | 19.1 ± 11.5 | 21.2 ± 11.9 | 17.3 ± 9.5 | 28.9 ± 23.5 | 21.8 ± 13.1 | 25.1 ± 25.5 | 18.7 ± 11.3 | 20.5 ± 11.8 | 25.9 ± 17.0 |
2005 | 19.6 ± 10.6 | 23.9 ± 12.1 | 17.4 ± 10.9 | 26.7 ± 21.5 | 23.2 ± 14.1 | 23.9 ± 19.4 | 19.1 ± 10.4 | 19.6 ± 10.2 | — |
2006 | 20.4 ± 11.2 | 24.5 ± 23.5 | 18.8 ± 9.8 | 24.8 ± 18.0 | 24.5 ± 20.8 | 22.9 ± 15.5 | 20.6 ± 10.8 | 21.2 ± 11.7 | — |
Overall average | 19.9 ± 11.1 | 23.2 ± 15.1 | 18.7 ± 10.9 | 29.3 ± 23.5 | 24.7 ± 17.5 | 25.3 ± 20.8 | 20.0 ± 11.4 | 20.9 ± 11.9 | 24.1 ± 9.0 |
Year | Monitoring stations | ||||||||
---|---|---|---|---|---|---|---|---|---|
MS1 | MS2 | MS3 | MS4 | MS5 | MS6 | MS7 | MS8 | MS9 | |
2002 | — | — | — | 17.3 ± 17.9 | 13.0 ± 8.0 | 12.5 ± 8.0 | 12.0 ± 8.1 | 11.8 ± 7.2 | 12.6 ± 7.9 |
2003 | — | — | — | 15.5 ± 13.6 | 14.5 ± 10.3 | 14.0 ± 9.9 | 14.2 ± 10.4 | 15.5 ± 10.7 | 17.4 ± 10.1 |
2004 | — | — | — | 17.0 ± 18.4 | 12.6 ± 7.4 | 11.5 ± 7.9 | 11.5 ± 7.4 | 12.1 ± 7.5 | 19.4 ± 13.3 |
2005 | — | — | — | 15.4 ± 16.3 | 12.9 ± 8.2 | 11.9 ± 8.2 | 11.9 ± 7.5 | 12.0 ± 7.4 | — |
2006 | — | — | — | 14.6 ± 12.9 | 13.0 ± 8.0 | 12.1 ± 8.0 | 12.1 ± 7.8 | 12.9 ± 7.4 | — |
Overall average | — | — | — | 16.0 ± 15.8 | 13.2 ± 8.4 | 12.9 ± 8.4 | 12.4 ± 8.2 | 12.9 ± 8.0 | 16.5 ± 6.2 |
Year | Monitoring stations | |||||
---|---|---|---|---|---|---|
MS10 | MS11 | MS12 | MS13 | MS14 | MS15 | |
2009 | 24.8 ± 15.5 | 18.2 ± 11.0 | 19.3 ± 11.6 | 14.7 ± 7.9 | — | 15.5 ± 9.2 |
2010 | 23.6 ± 16.8 | 17.2 ± 11.2 | — | 15.7 ± 13.9 | — | 14.8 ± 10.3 |
2011 | 25.1 ± 18.3 | 18.7 ± 12.6 | — | 20.4 ± 11.8 | — | 20.0 ± 13.2 |
2012 | 22.2 ± 16.1 | 18.6 ± 13.7 | — | 16.4 ± 9.7 | — | 18.0 ± 15.4 |
2013 | 19.7 ± 12.8 | 15.6 ± 9.4 | — | 20.0 ± 11 | 17.4 ± 12.7 | 19.1 ± 13.6 |
Overall average | 23.1 ± 16.1 | 17.7 ± 12.3 | 19.3 ± 11.6 | 17.4 ± 11.2 | 17.4 ± 12.7 | 17.5 ± 13.1 |
Year | Monitoring stations | |
---|---|---|
MS16 | MS17 | |
2011 | 37.3 ± 33.0 | 35.3 ± 31.2 |
2012 | 28.5 ± 24.3 | 38.6 ± 24.6 |
Overall average | 32.9 ± 19.3 | 34.9 ± 18.1 |
In general, the concentrations observed during the working hours were higher than those during non-working hours (ESI Tables S1–S4†), presumably due to construction activities and the other emission sources such as road vehicles in operation during working hours. Moreover, exhaust and non-exhaust construction sources were at rest during the non-working hours and therefore these are unlikely to contribute to the observed variations during the night. Because there was no major roadway around CS1, the variation in particle mass concentrations (PMCs) between the three construction sites during working and non-working hours could be attributed to the variability in meteorological conditions (mainly wind speed and direction; Fig. 2 and 3) during the different years of the measurements. Overall, the PM10 values were about ∼24%, 18% and 120% larger during the working periods when compared with those observed during the non-working periods at CS1, CS2 and CS3, respectively. Moreover, at CS1, there was an increase of about 11% in PM2.5 values during the working period when compared with the non-working periods (ESI Fig. S2†).
A comparison of the 24 hour average concentrations of PM10 with the EU Directive 2008/50/EC,42 as described in Table 7, suggests the number of exceedences each year (Table 8 and ESI Fig. S5†). However, these exceedences are not expected to be due to construction works alone, given that the winds were blowing from various directions (Fig. 1 and 2) and the presence of nearby sources could also have made a contribution to these exceedences. Therefore, we filtered the data based on the wind direction on an hourly basis at each monitoring station (Fig. 8). The monitoring stations downwind of the construction sites were then considered for the comparison with the 24 h mean EU limit value of 50 μg m−3 to observe the influence of construction works on the exceedences. The values in the parenthesis in Table 8 shows these exceedences possibly due to the construction activities, which were, except on two occasions in 2003 (Table 8), less than the allowable 35 exceedences per year (Table 7). Unlike previous studies13 where the exceedences of daily mean PM10 concentrations were reported over the EU limit value of 50 μg m−3 on several occasions during the monitoring of emissions from road and building works in London, our exceedences are within the regulatory limits and could also be attributed to the construction works, given that the paired polar roses and k-means clusters analysis in Sections 3.1–3.3 suggesting a clear contribution of the construction works on the downwind monitoring stations.
Pollutant | Period of averaging | Limit values | Dates to achieve |
---|---|---|---|
a The EU Directive 1999/30/EC stipulates that the annual mean values of PM10 should be less than 20 μg m−3 and should not exceed a mean of greater than 50 μg m−3 more than 7 days in a year as per the 2010 target limit values. These target values to be met by 2010 were not carried forward in the Directive 2008/50/EC.42 | |||
EU limit value | |||
PM10 | 24 hour mean | 50 μg m−3 not to be exceeded more than 35 times a year | January 2005 |
Calendar year | 40 μg m−3 | January 2005 | |
24 hour mean | 50 μg m−3 not to be exceeded morea than 7 times a year (target limit value) | January 2010 | |
Calendar year | 20 μg m−3 (target limit value)a | January 2010 | |
UK government AQS objective | |||
PM10 | 24 hour mean | 50 μg m−3 not to be exceeded more than 10–14 times a year | January 2010 |
Calendar year | 23–25 μg m−3 | January 2010 |
Monitoring stations | Monitoring years | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
2002 | 2003 | 2004 | 2005 | 2006 | 2007 | 2008 | 2009 | 2010 | 2011 | 2012 | 2013 | |
MS1 | 0(0) | 0(0) | 2(2) | 1(1) | 0(0) | — | — | — | — | — | — | — |
MS2 | 3(2) | 17(14) | 3(1) | 2(2) | 5(3) | — | — | — | — | — | — | — |
MS3 | 1(0) | 9(7) | 0(0) | 1(1) | 0(0) | — | — | — | — | — | — | — |
MS4 | 9(6) | 60(48) | 19(12) | 11(7) | 5(4) | — | — | — | — | — | — | — |
MS5 | 18(16) | 22(16) | 1(0) | 6(6) | 15(14) | — | — | — | — | — | — | — |
MS6 | 7(4) | 42(36) | 16(15) | 9(6) | 6(6) | — | — | — | — | — | — | — |
MS7 | 1(0) | 11(7) | 1(1) | 1(1) | 1(0) | — | — | — | — | — | — | — |
MS8 | 0(0) | 14(12) | 2(0) | 1(0) | 1(1) | — | — | — | — | — | — | — |
MS9 | 4(4) | 6(5) | 3(0) | 0(0) | 0(0) | |||||||
MS10 | — | — | — | — | — | — | — | 3(1) | 17(3) | 28(10) | 12(12) | 6(5) |
MS11 | — | — | — | — | — | — | — | 0(0) | 11(7) | 31(10) | 16(14) | 13(13) |
MS12 | — | — | — | — | — | — | — | 0(0) | 0(0) | 3(3) | 5(4) | 0(0) |
MS13 | — | — | — | — | — | — | — | 0(0) | 0(0) | 3(2) | 1(1) | 0(0) |
MS14 | — | — | — | — | — | — | — | 0(0) | 0(0) | 0(0) | 0(0) | 0(0) |
MS15 | — | — | — | — | — | — | — | 0(0) | 0(0) | 7(5) | 6(5) | 2(2) |
MS16 | — | — | — | — | — | — | — | — | — | 20(17) | 4(4) | — |
MS17 | — | — | — | — | — | — | — | — | — | 25(22) | 33(22) | — |
Fig. 9 shows the decay profiles of the PM10 and PM2.5 concentrations with the changing distance from CS1 and CS2. Both the logarithmic (Fig. 9a) and exponential (Fig. 9b) best-fit functions were applied to our ΔPM10 and ΔPM2.5. The logarithmic decay function (Fig. 9a) was chosen as a best fit to our data based on better R2 values than those given by an exponential decay profile as 0.79, 0.90 and 0.89 for PM10 (CS1), PM10 (CS2) and PM2.5 (CS1), respectively (Fig. 9b). The differences between the hourly averages of PM10 and PM2.5 concentrations (ΔPM10 and ΔPM2.5) during the working and non-working time periods provided the net concentrations from the construction activities, which were then used to draw decay profiles (Fig. 9). Furthermore, the calculated concentrations for PM10 and PM2.5 were filtered on the basis of prevailing wind direction.
The decay profile of the PM10 concentrations at CS1 was drawn using the data measured at MS4, MS5, MS7 and MS3, which were 100, 200, 500 and 1000 m away from CS1, respectively. Moreover, the data measured at MS4, MS6 and MS7 were used to draw the decay profile of PM2.5 at CS1, which were 100, 200 and 500 m away from CS1, respectively. Furthermore, the decay profiles of the PM10 concentrations were measured at 100, 200 and 400 m away from CS2 at MS10, MS11 and MS15, respectively.
Because of atmospheric dilution, the mass concentration dramatically decreased with an increasing distance from the construction site to approximately half of its value at a distance between 100 and 200 m. The best fitting logarithmic decay equations for PM10 were drawn, which gave R2 values of 0.92 and 0.91 for CS1 and CS2, respectively (Fig. 9a). A much higher rate of change in the PM concentrations can be observed close to the construction site when compared with those at greater distances. For instance, the rate of change in PM10 (CS1) concentration with per meter distance was 0.06 μg m−3 in between 100 and 200 m, which decreases to 0.030 and 0.013 μg m−3 per meter distance in the 200–400 m and 400–1000 m range, respectively (Fig. 9a). These observations suggest to measure the PM within a few 100 meters distance from the construction sites to capture the rapid decay in PMCs. The total mean PM2.5 levels around CS1 were also correlated well with the distances. A logarithmic decay profile with R2 value of 0.90 represented the measured data very well.
Although studies measuring the decay of the PM concentrations around the construction sites are rare, we tried to compare our data with the most relevant studies. For example, Hitchins et al.63 determined the PM10 concentration at increasing distances from a road at two sites in Australia. They found that PM2.5 and ultrafine particles decayed by up to half of their maximum initial concentrations within a distance of 100–150 m from the road. Likewise, Buonanno et al.64 found the PM10 concentration values to decrease exponentially away from the freeway in Italy during weekly traffic conditions.
The following conclusions are drawn from this study:
The source characteristics of PM10 and PM2.5 were investigated using bivariate concentration polar plots and k-means clustering techniques. The high concentrations of PM10 and PM2.5 were observed at the paired monitoring stations during the construction works when the winds were blowing from construction sites towards the monitoring stations. A k-means clustering technique provided a useful development to the bivariate polar plots to assess the contribution of construction and other local sources.
Three clusters (5, 6 and 7) from a total of the 8 selected clusters showed strong evidence of a downward increase in PM10 and PM2.5 levels during the weekdays. These clusters were identified to represent construction activities.
PM10 were found about ∼24%, 18% and 120%, and PM2.5 about 11%, larger during the working periods when compared with those during non-working periods at CS1, CS2 and CS3, respectively. These increases were attributed to the construction works as indicated by the bivariate concentration polar plots and k-means clustering analysis. In addition, the downwind concentrations of PM10 were found to be relatively more influenced by construction works at CS1 than the PM2.5 concentrations.
The 24 h mean EU limit of value of 50 μg m−3 set by EU Directives for PM10 not to be exceeded more than 35 times a calendar year was breached on two occasions due to construction operations on downwind monitoring stations during the measurements taken between 2002 and 2013.
Both the total PM10 and PM2.5 values during working periods in the downwind direction were found to be well correlated with distance with R2 values over 0.90 in a logarithmic form. These concentrations reduced to half of their initial concentrations within a few 100 meters. This indicates that placing a monitoring station around a site within this peripheral distance could help capture the rapid decay of particles escaping from the construction sites.
The results presented in this study highlight the contributions of PM10 and PM2.5 from construction works. The increase in the concentrations of PM10 and PM2.5 at the downwind monitoring stations suggest that there is a need to design more detailed and appropriate risk mitigation strategies to limit the exposure to onsite workers and people that live in the surrounding environment. Further studies covering chemical fingerprinting of size fractionated PM from construction operations are recommended to understand their chemical composition as well as apportioning construction dust (e.g. using calcium and other similar minerals as a marker) from the exhaust emissions of construction machinery (e.g. using black carbon as a marker65), together with allowing to differentiate between the properties of construction dust and the PM produced by the most common source (i.e. road vehicles) in urban environments.16,66
Footnote |
† Electronic supplementary information (ESI) available: Sections S1–S2, Tables S1–S4 and Fig. S1–S5. See DOI: 10.1039/c5em00549c |
This journal is © The Royal Society of Chemistry 2016 |