Issue 23, 2023

Efficient and rapid linker optimization with heterodimeric coiled coils improves the response of fluorescent biosensors comprising antibodies and protein M

Abstract

We developed a coiled Q-probe (CQ-probe), a fluorescent probe containing a coiled-coil peptide pair E4/K4, to convert antibodies into biosensors for homogeneous immunoassays. This probe consists of an antibody-binding protein, protein M (PM) with the E4 peptide and the K4 peptide with a fluorescent dye. Compared to PM Q-probes, which are generated by modifying the C-terminus of PM with a fluorescent dye, CQ-probe variants with various linkers are easy to prepare and therefore enable the establishment of biosensors with a significant fluorescence response by localizing the fluorescent dye at the optimal position for quenching and antigen-dependent release. The fluorescence changes of biosensors converted from anti-BGP, anti-cortisol, and anti-testosterone antibodies using the rhodamine 6G (or TAMRA)-labeled CQ-probe upon antigen addition were 13 (or 2.6), 9.7 (or 1.5), and 2.1 (or 1.2) times larger than that of the biosensors converted using the PM Q-probe. Furthermore, the CQ-probe converted anti-digoxin IgG into a functional biosensor, whereas the PM Q-probe/antibody complex showed an insufficient response. This technology exhibits a promising capacity to convert antibodies into high-response biosensors, which are expected to be applied in a wide range of fields, including clinical diagnosis, environmental surveys, food analysis, and biological research.

Graphical abstract: Efficient and rapid linker optimization with heterodimeric coiled coils improves the response of fluorescent biosensors comprising antibodies and protein M

Supplementary files

Article information

Article type
Communication
Submitted
01 септ. 2023
Accepted
28 окт. 2023
First published
31 окт. 2023

Analyst, 2023,148, 5843-5850

Author version available

Efficient and rapid linker optimization with heterodimeric coiled coils improves the response of fluorescent biosensors comprising antibodies and protein M

K. Sasamoto, T. Yasuda, B. Zhu, H. Ueda and T. Kitaguchi, Analyst, 2023, 148, 5843 DOI: 10.1039/D3AN01499A

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements