Guotao
Sun
a,
Yao
Xie
b,
Lining
Sun
*ab and
Hongjie
Zhang
*c
aSchool of Materials Science and Engineering, Shanghai University, Shanghai 200444, China. E-mail: lnsun@shu.edu.cn
bResearch Center of Nano Science and Technology, College of Sciences, Shanghai University, Shanghai 200444, China
cState Key Laboratory of Rare Earth Resource Utilization, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022, China. E-mail: hongjie@ciac.ac.cn
First published on 29th July 2021
Biomolecules play critical roles in biological activities and are closely related to various disease conditions. The reliable, selective and sensitive detection of biomolecules holds much promise for specific and rapid biosensing. In recent years, luminescent lanthanide probes have been widely used for monitoring the activity of biomolecules owing to their long luminescence lifetimes and line-like emission which allow time-resolved and ratiometric analyses. In this review article, we concentrate on recent advances in the detection of biomolecule activities based on lanthanide luminescent systems, including upconversion luminescent nanoparticles, lanthanide–metal organic frameworks, and lanthanide organic complexes. We also introduce the latest remarkable accomplishments of lanthanide probes in the design principles and sensing mechanisms, as well as the forthcoming challenges and perspectives for practical achievements.
The luminescent mechanisms of lanthanide ions can be divided into two categories, upconversion luminescence and traditional downshifting luminescence (Fig. 1). Lanthanide upconversion luminescence is an anti-Stokes shift process where lanthanide ions absorb lower energy photons and emit higher energy photons, while downshifting luminescence is a Stokes shift process in which higher energy excitation light is converted into lower energy emission light. For the lanthanide upconversion process, upconversion nanoparticles (UCNPs) are the typical representation. For the downshifting process, lanthanide-metal organic frameworks (Ln-MOFs) and lanthanide organic complexes which consist of lanthanide ions as luminescent centers and organic molecules as antenna ligands are the primary subjects of study.
Fig. 1 Schematic illustrations of lanthanide upconversion (A) and downshifting (B) luminescence. 1 represents the ground state, and 2 and 3 represent the excited states. |
Recently, with the development of biomedicine applications, biomolecules associated with biological activities and many diseases have attracted increasing interest in the sensing field.18–24 The stable, selective and sensitive detection of biomolecules by prospective luminescent probes holds much promise for specific and rapid biosensing. Up to now, a variety of successful biomolecule detection approaches and techniques have been developed. However, the disadvantages for implementation such as cost, reproducibility, mobility, and efficiency often lead to hard decisions under biological conditions. Recently, luminescent probes have been widely applied for biomolecule detection due to their unique optical properties. Traditional sensing techniques such as high performance liquid chromatography (HPLC) and liquid chromatography-mass chromatography usually cost much time and money and require a laboratorial environment to operate, while lanthanide luminescent probes are often cheap and can be applied in a wide range of situations owing to their easy fabrication and portability. Lanthanide probes allow the identification of a variety of analytes and factors according to the changes in wavelength, emission intensity, luminescence lifetimes or polarization.8,25–27
Several remarkable review articles have been published to emphasize the potential of lanthanide-related materials for bioimaging and biomedicine achievements.4,28–30 In this review, we will concentrate on the literature of the past few years covering the recent advances of lanthanide-based systems for the detection of biomolecules. We begin by surveying the recent advances in the designed UCNPs to detect biomolecules, including amino acids, proteins, tumor biomarkers, nucleic acids, and so on. Next, we give a careful overview of the detection principles of Ln-MOFs and lanthanide complexes for biomolecules and discuss their sensing mechanisms and detection formats. We finish the review by assessing current challenges and presenting the prospects of lanthanide-based luminescent probes for fundamental studies and biomolecule detection.
The design of most UCNP-based biomolecule detection systems reported up to now is usually dependent on the Förster resonance energy transfer (FRET) effect in which the detection results rely on the luminescence switch off/on or lifetime variations. FRET is a mechanism which describes the energy transfer process when the emission spectrum of an energy donor and the excitation spectrum of an energy acceptor overlap. The energy transfer process usually occurs when the donor chromophore and acceptor chromophore are in close proximity.32 So, the efficiency of the energy transfer is extremely sensitive to small changes in distance.33,34 During the FRET process, UCNPs usually serve as energy donors. By making use of surface decorating strategies, a series of energy acceptors, like metal nanoparticles and organic dyes, have been modified onto the surfaces of UCNPs for sensing various analytes. In this part, we will review the recent achievements of designed UCNPs to perform high performance detection toward biomolecules.
Amino acid derivatives are substances formed by the combination of amino acids through a series of reactions. Various amino acid derivatives play important roles in the human body, so a series of nanosensors based on amino acid derivatives have also been developed. Glutathione (GSH) is an important type of amino acid derivative. Zheng and colleagues constructed a nanoprobe that can simultaneously detect the GSH/H2O2 ratio.37 As shown in Fig. 2A, the UCNPs are simultaneously linked to TCG (GSH sensitive dye) and BCH (H2O2 sensitive dye). The ratios of the upconversion luminescence intensities at 540 and 650 nm to that at 800 nm are used as detection signals, respectively. Liu's group proposed a new strategy to use organic dyes as targets to adjust the sensitization switch to prepare upconversion nanoprobes to detect intracellular GSH.38 The organic dye acts as both a target's identification unit and a potential antenna. Before reacting with the target, the dye is non-emissive and will not be sensitized. After reacting with GSH, the dye will emit light strongly and cause upconversion luminescence sensitization through the nonradiative energy transfer process.
Fig. 2 (A) Schematic diagram of an upconversion nanoprobe that can simultaneously monitor GHS and H2O2in vivo.37 Copyright 2019, Springer Nature. (B) Schematic diagram of a nanosensor that can be used to detect caspase-9 activity in vivo and in vitro.40 Copyright 2019, Elsevier. |
Amino acids are dehydrated and condensed into proteins, which are important biological macromolecules that compose all cells and tissues of the human body. Many upconversion nanoprobes for detecting proteins and enzymes have been successfully investigated. For example, Wang's group developed a new strategy to prepare intelligent upconversion fluorescent materials for highly specific enrichment and sensing of glycoproteins.39 Song's group successfully constructed a FRET sensing system based on peptide-functionalized UCNPs,40 which can detect caspase-9 in vivo and in vitro. As shown in Fig. 2B, the cleavage of Cy5 fragments on the surfaces of the UCNPs by caspase 9 leads to the restoration of red upconversion fluorescence. Higher caspase-9 activity will cause stronger recovery of the red emission. The signal intensity ratio of the red emission to green emission of the UCNPs is linearly related to the caspase-9 activity. You et al. also utilized the FRET effect to develop a new type of nanoprobe based on UCNPs conjugated with phycocyanin to detect the fluctuation of myeloperoxidase.41 Phycocyanin is attached onto the surfaces of the UCNPs through amidation reaction, and the luminescence of the UCNPs is quenched by energy transfer from phycocyanin. The luminescence of the nanoprobe will be restored after phycocyanin specifically recognizes the myeloperoxidase. Using the same sensing strategy, Zhang's group designed sandwich-structured UCNPs (NaYF4:Yb/Er@NaErF4@NaYF4), which can serve as a nanoprobe for the detection of alkaline phosphatase.42 The UCNPs act as an energy donor in this system, and the complex, composed of ferric ions and sulfosalicylic acid, acts as an energy acceptor. In the presence of phosphate, the ferric ions were separated from the complex and coordinated with phosphate ions, resulting in an impediment to the energy transfer and the recovery of luminescence.
Carcinoembryonic antigen (CEA) is a kind of protein often linked with colorectal cancer. UCNPs combined with titanium dioxide upconversion microrods (NaYF4:Yb,Tm@TiO2) were designed for the detection of CEA52 (Fig. 3A). The carcinoembryonic antigen was discovered on a magnetic bead by utilizing specific aptamers. Under optimal conditions, the UCNP-based aptamer sensing system can emit a distinct signal in response to CEA and enable the detection limit of CEA as 3.6 pg mL−1. To meet the challenges of point-of-care detection and achieve the capability of multiplex detection, Tang's group reported an imageable suspension array based on UCNPs luminescence encoding for the determination of alpha fetal protein and CEA.53 As shown in Fig. 3B, the different target binding processes are differentiated by using two species of UCNPs (B-UCNPs and G-UCNPs) as luminescent indicators, and a sandwich complex bead is made of carboxyl functionalized polystyrene beads. Using this bead assay, the detection limits of alpha fetal protein and CEA are 2.7 pg mL−1 and 3.1 pg mL−1, respectively.
Fig. 3 (A) Schematic illustration of a sandwich platform for determination of target CEA based on UCNPs@TiO2 microrods with rolling circle amplification upon irradiation with near-infrared light.52 Copyright 2018, American Chemical Society. (B) Schematic showing the imaging-based suspension array by combining optical tweezers with upconversion luminescence for sensing CEA and alpha fetal protein with sandwich immunological recognition, where CEA and alpha fetal protein are monitored by green emission and blue emission signals, respectively.53 Copyright 2018, American Chemical Society. |
Prostate-specific antigen (PSA) as a biomarker of prostate cancer was detected by single-particle enumeration based on UCNPs and gold nanoparticles.54 The carboxyl group-functionalized UCNPs decorated with anti-PSA detection antibodies play the role of energy donor, and gold nanoparticles conjugated with anti-PSA capture antibodies serve as the energy acceptor. In the presence of PSA, the immunoreaction drags UCNPs and gold nanoparticles into proximity, resulting in FRET between them, leading to luminescence quenching.
Jin's group designed UCNPs functionalized with a bispecific antibody to recognize the cancer antigen biomarker.55 To achieve this, one end of the bispecific antibody was synthesized to recognize UCNPs, and the other end of the bispecific antibody was designed to conjugate the cancer antigen biomarker. By using the same strategy, Lan and co-workers synthesized UCNPs modified with a DNA aptamer sensor according to the structure of vascular endothelial growth factor (a biomarker of breast cancer).56 In this system, the UCNPs were decorated with aptamer DNA by replacing the oleic acid on the surfaces. With the introduction of vascular endothelial growth factor, the upconversion luminescence signal was changed and detected upon irradiation with 980 nm light, leading to the determination of this biomarker with a detection limit of 6 pM. In these examples, UCNPs were decorated with functional moieties that can recognize biomolecules or play a role in energy transfer which results in luminescence change. Based on the luminescence change of UCNPs, the tumor biomarker 5-hydroxyindoleacetic acid was detected using a sensing probe comprised of silica spheres and UCNPs.57 The sensing mechanism is based on the recovery of the fluorescence of UCNPs with the introduction of 5-hydroxyindoleacetic acid.
Apart from tumor biomarker detection, researchers also concentrate on designing luminescent sensors for cancer cell sensing. UCNPs combined with TiO2/CdTe heterostructures were synthesized for use as a film electrode, and the aptamer AS1411 was linked to this electrode to specifically recognize breast cancer cells (MCF-7 cells).58 In this system, the UCNPs convert near-infrared (NIR) light to visible light, which excites the semiconductor to improve the current response, resulting in the detection of MCF-7 cells ranging from 1 × 103 to 1 × 105 cells per mL. Guo et al. designed a luminescent lanthanide nanoprobe to detect circulating tumor cells,59 which is a kind of blood biomarker for the evaluation of cancer metastasis and early cancer diagnosis. They first designed antibody-modified lanthanide nanoparticles (NaEuF4–Ab) and microplate wells modified with anti-epithelial cell adhesion molecule antibodies. Owing to recognition between the antigens and antibodies of epithelial cell adhesion molecules, cancer cells can coordinate with NaEuF4–Ab. Utilizing the time-resolved luminescence of these lanthanide particles, circulating tumor cells can be detected in the enhancer solution with a detection limit of 1 cell per well. Zhang's group also took advantage of time-resolved luminescence for sensing hepatocellular carcinoma.60 They designed a tumor-microenvironment (ONOO−)-responsive lanthanide–dye FRET sensor in which lanthanide nanoparticles serve as an energy donor, and the dye MY-1057 serves as an energy acceptor. The tumor areas can be differentiated from normal tissue according to the recovery lifetime.
Nucleic acid sensing systems with high spatiotemporal resolution have been successfully constructed because of the development of some highly sensitive sensors based on upconversion luminescence. This type of system can be used for both quantitative detection of nucleic acids and biological imaging in vivo. Li's group constructed an activatable DNA nanodevice that uses the high spatial and temporal precision of NIR light to detect miRNAs in vivo.66 This nanodevice is functionalized on the surfaces of UCNPs through a DNA beacon, which can sense miRNA under UV light excitation. Later they focused their attention on the use of UCNPs to achieve signal amplification controlled by NIR light. They redesigned the functional unit of the hybridization chain reaction and combined it with UCNPs.67 The hybridization chain reaction method excited by NIR light will enable signal amplification and imaging of RNA targets in living cells with high spatiotemporal accuracy.
A ratiometric sensor which is designed with a ratio of two luminescent signals for self-calibration is a promising technique for measuring analytes especially in biological fluids, tissue samples, and live cells. Wang and co-workers designed a UCNP-based ratiometric probe (UCNP@RdMMSN@βCD) with two emission peaks at 540 and 656 nm for detecting nitric oxide in Oct-treated rat IR models69 (Fig. 4A). The emission intensity ratio (I656/I540) of this system was investigated with the addition of NO and other reactive nitrogen and oxygen species (Fig. 4B). With the introduction of NO, the upconversion emission intensity at 656 nm remained stable, while the emission intensity at 540 nm decreased. In contrast, no obvious change was observed when this ratiometric probe was treated with other oxidative chemical species. Chen's group designed NIR dual-excitation ratiometric luminescence probes based on dye-sensitized UCNPs to detect hypochlorite in live MCF-7 cells70 (Fig. 4C). The dye IR808, as a recognizer of hypochlorite in cells, is treated as an energy donor and UCNPs are used as an energy acceptor in this probe. With the introduction of NaClO, the luminescence intensity of IR808-UCNPs-F127 gradually decreased (Fig. 4D) upon 808 nm excitation. The upconversion luminescence signal excited using a 980 nm laser is not influenced by analytes, and thus can serve as a self-calibrated signal and alleviate the interference due to environmental change. The ratiometric probes improve detection accuracy via the self-calibration of two signal intensities, where one signal serves as a reference factor for adjusting another signal. Thus, the ratiometric detection is independent of sensor concentration and a variety of analyte-independent factors, leading to more reliable and accurate quantitation.
Fig. 4 (A) Schematic illustration of UCNPs for ratiometric sensing of nitric oxide.69 Under 980 nm light excitation, the nanoprobe exhibits two luminescent emission signals at 540 nm and 656 nm. The UCNPs as the core are encapsulated within a shell of mesoporous SiO2, where pores are filled with rhodamine B-derived molecules. (B) (a) Upconversion luminescence spectra and luminescence intensities (inset) of the probes. Error bars were from three parallel experiments. (b–d) Luminescence ratiometric photographs of rat liver tissue slices cultivated with the probes and the corresponding signal profile of a linear area across the rat liver slices under 980 nm excitation (the scale bar is 200 μm).69 Copyright 2017, American Chemical Society. (C) Schematic showing the ratiometric sensing process of intracellular ClO−1 in a dye-sensitized UCNP probe and the corresponding analyte-dependent energy transfer mechanism.70 (D) Upconversion luminescence spectra of the IR808-UCNPs-F127 probe with the introduction of NaClO under 808 nm excitation.70 Copyright 2019, John Wiley & Sons. |
UCNPs integrated with other materials into one architecture for biomolecule sensing overcome some limitations of solo materials, which can improve the range of application and luminescence performance. Recently, Gu et al. reported an electrochemiluminescence sensor based on UCNP and covalent organic framework hybrid materials,71 for monitoring dopamine in serum samples. The porous covalent organic framework-based electrochemiluminescent probe could load more UCNPs to enhance the luminescence intensity and imprint the recognition sites for dopamine determination. Recently, a sensor based on UCNPs encapsulated within metal organic frameworks (ZIF-8) and incorporating a molecularly imprinted polymer for discovering octopamine was synthesized by Fang's group.25 The luminescence intensity and dispersity of UCNPs can be enhanced by the stability and high surface area of the MOFs under organic conditions, which can improve the detection limit for octopamine.
A solid-phase biosensor combined with Au nanocaps and UCNPs decorated with quencher-marked aptamers in a solid substrate was designed for the detection of ochratoxin A.72 The upconversion luminescence of UCNPs can be quenched by the FRET between the quencher (aptamers) and UCNPs. Another example based on UCNP hybrid materials is that Au nanoparticles harvest light from UCNPs which convert NIR light into visible light, for sensing the concentration of reactive oxygen species.73
In recent work, a molecular imprinting technique is to attain the close interaction between the target molecule and UCNPs for rhodamine B sensing. The authors first synthesized UCNPs with a molecularly imprinted polymer at the surface where molecular cavities can selectively capture target molecules74 with a detection limit of 6.27 μg mL−1. Another example is that a fluorescent “double recognition” method combined with UCNPs and a molecular imprinting technique for detecting enrofloxacin to overcome conventional limitations of molecular imprinting including high cost, poor stability, and hard availability.75 The UCNPs combined with the molecular imprinting technique can improve the interaction between biomolecules and UCNPs by shortening the distance between them, which is a useful method for specific targeting and detection of biomolecules.
The large superficial area of UCNPs may combine with numbers of biomolecules, resulting in a too dark or too light sensor in color. As a result, it is difficult to realize the color change with naked eyes. A placeholder strategy based on UCNPs was designed by Cheng and coauthors, to monitor dipicolinic acid (DPA), an acid anthrax biomarker.76 The large surface area of UCNPs was partly occupied by sodium tripolyphosphate and eriochrome black T. In general, DPA displaces eriochrome black T from this nano-system, which causes a color change from red to blue due to the release of free eriochrome black T into the solution. The detection limit of DPA is 0.9 μM, lower than the infectious dose of anthrax spores (60 μM).
To achieve rapid and cost-effective assays, Li et al. synthesized a [Tb(HL)L(H2O)]n test stripe for sensing tetracycline antibiotics in aqueous solution.86 Based on the quenching mechanism due to the inner filter effect, the tetracycline antibiotics can be sensitively detected using the [Tb(HL)L(H2O)]n test stripe, and the detection limit for tetracycline antibiotics is 2.77 nM, comparable to that of the HPLC detection method. Based on photoinduced energy transfer between lanthanide ions and antibiotics, Wang et al. produced an Eu-MOF for the detection of metronidazole and dimetridazole antibiotics in aqueous solution and organic solution.87 The detection limits of dimetridazole and metronidazole antibiotics are 13.4 ppm and 13.0 ppm, respectively, indicating that this Eu-MOF is promising in the diagnosis of antibiotic poisoning. Yu and co-workers designed a “turn-on” luminescent probe based on an Eu-MOF,88 for the detection of doxycycline, a polyketide antibiotic. The Eu-MOF was initially non-fluorescent; with the introduction of doxycycline, this probe showed obvious fluorescence improvement at 526 and 617 nm. Furthermore, the system can be successfully used as a sensing material for the detection of doxycycline in samples of urine and fish.
Dong et al. reported mixed membranes which are composed of Eu1−xTbx-MOF and polymer materials,89 further improving the flexibility of Ln-MOFs. In this study, Ln-MOFs were produced from europium/terbium nitrate and the ligand H4L in DMA–H2O solution at 100 °C. By changing the reactant time, submicrometer Ln-MOF (SMOF-10–10 h) spheres were obtained for easier and faster sensing applications. The luminescence experiments showed that the SMOF-10–10 h membrane had unique emission peaks of Eu3+and Tb3+ions that could detect different antibiotics in a certain concentration range on the basis of the emission ratio with I618/I594 for Eu3+ions (y-axis) and I544/I489 for Tb3+ions (x-axis) in a two dimensional map. With the increase of Tb3+, the color of Eu1−xTbx-MOF changed from magenta to green because Eu3+ ions were sensitized by Tb3+ ions.
Fig. 5 (A) Schematic illustration of the luminescence quenching process of Ln(III)-MOF in response to miRNA-155 (a cancer biomarker) based on the FRET process.90 Copyright 2020, American Chemical Society. (B) Schematic showing Eu–QPTCA NMOFs that acted as luminescent probes to detect creatine kinase (cardiac marker) activity.93 Copyright 2019, American Chemical Society. |
Some examples are based on time-resolved techniques due to the long decay time of lanthanide ions, which can eliminate short-lived autofluorescence. Ln-MOF Eu–QPTCA was synthesized as a time-resolved luminescent probe for acute myocardial infarction which is an important cardiac biomarker; the detection limit of cardiac biomarker concentration was confirmed to be 1.0 U L−193 (Fig. 5B). In this system, Eu3+ ions are sensitized by organic ligands and exhibit red emission under 373 nm light excitation. Interestingly, the red emission signal can be quenched by adenosine triphosphate (ATP), but less influenced by adenosine diphosphate (ADP). These different luminescent emission behaviors in response to ATP and ADP enable the Eu–QPTCA NMOFs to become luminescent probes for creatine kinase, a transformative switch between ATP and ADP.
In order to improve the sensing reliability of biomarkers, Li's group provided a facile technique to fabricate a semi-solid EuMOF-gel that can sense an endogenous metabolite called α-ketoglutaric acid in serum.94 Almost at the same time, the same group provided another approach to tailor the performances of Eu–ZnMOF through structural engineering,95 which can detect the concentration variation of urinary vanillylmandelic acid, an early pathological signature of pheochromocytoma.
Due to the pH-related (pH 3–4) luminescence properties and the coordination effects from amino acids, Zhao and co-workers designed an Eu-MOF to monitor pH-related amino acids which can distinguish aspartic acid and glutamic acid from other amino acids with detection limits of 21 μM and 22.4 μM, respectively.99 Corresponding to the above properties, the luminescence switching mechanism is due to the coordination of water molecules and the slight elongation of Eu–O bond, resulting in the luminescence quenching of the lanthanide ions. Using the same idea, Xiao and co-workers reported a pH-modulated system based on dually-emitting Eu3+@Mn-MOF for detecting histidine.100
Fig. 6 (A) Schematic illustration of the luminescence “turn-on” process of Yb-NH2-TPDC for the detection of gossypol under 485 nm excitation. (B) Kinetics of the luminescence intensity of Yb-NH2-TPDC at 976 nm at different gossypol concentrations (λex = 485 nm). (C) Emission spectra of Yb-NH2-TPDC in gossypol solutions at different concentrations at 300 min. The inset diagram shows the calibration curve (λex = 485 nm).101 Copyright 2020, American Chemical Society. |
Several principles for designing efficient luminescent lanthanide complexes need to be considered. Firstly, it is difficult to directly excite lanthanide ions because of their Laporte forbidden property of the f–f transitions. However, the lanthanide complexes with efficient luminescence can be achieved by coordinating the lanthanide ions with a strongly absorbing antenna ligand. Secondly, lanthanide ions need to accept sufficient energy from the antenna ligand, so the energy gap between the triplet state of the ligand and the accepting energy levels of the lanthanide ions should be appropriate. Thirdly, lanthanide ions adopt coordination numbers between 7 and 10; as a result, the antenna ligand should have a sufficient number of donors to surround the lanthanide sphere.
Instead of classifying the analytes by species, we will define lanthanide complex probes by the categories of sensing strategies, such as the time-gated technique and ratiometric analyses, which can meet requirements in face of practical challenges.
There are many strategies to break the limitation of the lanthanide complex and have better effects in biomolecule detection. For example, to improve the detection limit of carcinoembryonic antigen (an important tumor marker in prognosis and clinical diagnosis), Chen's group replaced the Eu complex by using Eu micelles (Eu2O3@PAA) which can produce thousands of Eu3+ ions (Fig. 7A).110 This strategy takes advantage of dissolution-enhanced luminescence amplification. After the introduction of enhancer solution, the luminescence intensity (Fig. 7B) and lifetime (Fig. 7C) of PAA-capped Eu2O3 increased. The luminescent signal was measured by time-resolved technology to quantitatively monitor the concentration of carcinoembryonic antigen in saliva with a detection limit of 1.47 pg mL−1. Furthermore, upon illumination with UV light (365 nm), the luminescent signal of Eu2O3@PAA can be seen clearly in enhancer solution with naked eyes, but a weak signal in PBS solution (Fig. 7B, inset).
Fig. 7 (A) Schematic showing CEA detection via Eu2O3@PAA in saliva. Eu2O3 nanocrystals and a syringe filter are used as nanoprobes and a bioassay platform, respectively. The bioassay allows time-resolved and visual sensing of CEA. (B) Excitation spectra (left) and emission spectra (right) of Eu2O3@PAA in PBS solution and enhancer solution, respectively. Insets show the luminescent photographs of Eu2O3@PAA in PBS solution (left) and enhancer solution (right) with 365 nm light excitation. (C) Luminescence lifetime decays of Eu2O3@PAA in PBS solution and enhancer solution, respectively.110 Copyright 2021, John Wiley & Sons. |
Fig. 8 (A) Schematic representation of ratiometric Tb/DPA@SiO2–Eu/GMP complexes for DPA detection.111 Copyright 2017, Elsevier. (B) Fluorescent emissions of the Tb/DPA@SiO2−Eu/GMP probe with increase in DPA concentration (0–2.0 μM) (λex = 272 nm). (C) Schematic illustration of a ratiometric fluorescent Tb-COP complex and the process for DPA detection.112 Copyright 2019, Elsevier. (D) Fluorescence intensities of Tb-COP with different concentrations of DPA (0–30 μM) under 272 nm excitation. |
In addition to Tb3+, Eu3+ ions can also coordinate with DPA and form Eu complexes. Donmez et al. synthesized a ratiometric probe based on an EDTA–Eu3+ complex and fluorescein dye,113 for detecting DPA as well (detection limit = 10 nM). This probe takes advantage of the coordination ability of DPA with Eu3+, forming a luminescent EDTA–Eu3+/DPA complex. In this ratiometric fluorescent probe, the EDTA–Eu3+ is the sensing part, and fluorescein dye is the internal reference. The luminescent intensity of fluorescein dye remained constant when the Eu3+ emission increased with the addition of DPA. Using the same idea, Tang's group designed a nanoprobe based on a terbium functionalized micelle and a fluorophore for DPA detection; the detection limit is 54 nM.114 The Tb3+ ions in the micelle can be sensitized to emit unique luminescence with the introduction of DPA. The luminescence intensity of the fluorophore remained constant, resulting in ratiometric luminescence response for DPA. Recently, the same group reported Eu3+/Tb3+ hybrids for ratiometric detection of DPA (detection limit = 27.3 nM). Instead of using a fluorophore as fluorescence reference, they took advantage of the intrinsic emission peaks of Tb3+ (545 nm) and Eu3+ (613 nm) as the luminescence ratio (excitation wavelength: 280 nm).115 Both the fluorescence lifetimes and intensities of the luminescence ratio I545/I613 maintain a good correlation upon addition of DPA, which prove that these Eu3+/Tb3+hybrids as probes have a good sensing ability towards DPA.
As we can see from the examples mentioned above, use of analytes as ligands to coordinate lanthanide centers is an important strategy to fabricate luminescent sensors where lanthanide ions absorb energy from analytes and emit the characteristic fluorescence signal of lanthanide ions. Luminescent labels combined with other fluorophores can serve as ratiometric probes to achieve reliable and sensitive results.
First, although the sensitivity and selectivity of current luminescent probes are usually adequate for sensing single analytes, more efforts should be made towards the development of diversified systems which can monitor multiple biomolecules at the same time. Lifetime-based lanthanide luminescent probes are receiving increasing attention in multiplexed biosensing, which can eliminate signal distortion under biological conditions. Nevertheless, strategies for lifetime-based probes with sensitivity, selectivity, and fast feedback are lacking in exploiting. To achieve multiplexed sensing, more attention should be paid to working on the controlled lifetime responsiveness and precise synthesis of probes.
Second, the low upconversion luminescence efficiencies of UCNPs have been a key bottleneck for a long time, which may cause low sensitivity of biosensing and poor resolution. As a result, novel strategies to fabricate UCNPs for biosensing with high quantum efficiency are much needed. The UCNPs combined with other materials have become one of the promising methods for sensing, which can tackle some drawbacks of solo optical labels and fully take advantage of the merits of UCNPs and traditional fluorophores to obtain high quantum efficiencies of lanthanide nanoparticles. For example, the system of UCNPs conjugated with organic molecules can take advantage of the high light-absorption ability of organic molecules and then transfer energy to UCNPs, enhancing the luminescence efficiencies of the whole system.
Third, as of now, the long-term toxicity of UCNPs is another bottleneck for in vivo sensing of biomolecules, though a variety of surface modification approaches have been employed to alter the stability and toxicity of UCNPs. It is necessary to discover novel lanthanide upconversion materials. Recently, molecular upconversion was investigated, in which photons with high energy are emitted upon excitation of molecular or supramolecular systems with photons with low energy.116,117 These upconversion systems at the molecular level are a promising direction to overcome the constraint of UCNPs.
Fourth, for lanthanide complexes and Ln-MOFs, challenges including their short excitation wavelengths and low water solubility still exist for the detection of biomolecules. Here we propose some potential strategies in the design and development of multifunctional lanthanide probes for biomolecules: (i) developing new design rationales; (ii) exploiting probes based on ratiometric luminescence and time-resolved techniques – both the ratiometric assays and time-resolved techniques can greatly eliminate the influences due to environmental factors, resulting in reliable and sensitive detection; and (iii) combining other fluorophores with lanthanide complexes or Ln-MOFs, which can significantly improve the luminescent properties and functionality to meet the requirements of commercial applications.
Luminescent lanthanide-based systems including UCNPs, lanthanide complexes, and Ln-MOFs for biomolecule detection not only inspire researchers to study the advantages of different fluorophores but also enlighten researchers to discover new directions between luminescence science and biosensing. In addition, to meet different challenges in commercial applications, developing hybrid materials which can take full advantage of the potential properties of each material should be considered. We hope this review will broaden the horizons of the wider scientific groups about how to design and synthesize all kinds of hybrid systems for biomolecule detection.
This journal is © The Royal Society of Chemistry 2021 |