Issue 12, 2022

A plantar wearable pressure sensor based on hybrid lead zirconate-titanate/microfibrillated cellulose piezoelectric composite films for human health monitoring

Abstract

Flexible and wearable electronic sensors hold great promise for improving the quality of life, especially in the field of healthcare monitoring, owing to their low cost, flexibility, high electromechanical coupling performance, high sensitivity, and biocompatibility. To achieve high piezoelectric performance similar to that of rigid materials while satisfying the flexible requirements for wearable sensors, we propose novel hybrid films based on lead zirconate titanate powder and microfibrillated cellulose (PZT/MFC) for plantar pressure measurements. The flexible films made using the polarization process are tested. It was found that the maximum piezoelectric coefficient was 31 pC N−1 and the maximum tensile force of the flexible films was 26 N. A wide range of bending angles between 15° and 180° proves the flexibility capability of the films. In addition, the charge density shows a proportional relation with the applied mechanical force, and it could sense stress of 1 kPa. Finally, plantar pressure sensors are arranged and packaged with a film array followed by connection with the detection module. Then, the pressure curves of each point on the plantar are obtained. Through analysis of the curve, several parameters of human body motions that are important in the rehabilitation of diabetic patients and the detection of sports injury can be performed, including stride frequency, length and speed. Overall, the proposed PZT/MFC wearable plantar pressure sensor has broad application prospects in the field of sports injury detection and medical rehabilitation training.

Graphical abstract: A plantar wearable pressure sensor based on hybrid lead zirconate-titanate/microfibrillated cellulose piezoelectric composite films for human health monitoring

Supplementary files

Article information

Article type
Paper
Submitted
14 janv. 2022
Accepted
02 mai 2022
First published
02 mai 2022

Lab Chip, 2022,22, 2376-2391

A plantar wearable pressure sensor based on hybrid lead zirconate-titanate/microfibrillated cellulose piezoelectric composite films for human health monitoring

Y. Guan, M. Bai, Q. Li, W. Li, G. Liu, C. Liu, Y. Chen, Y. Lin, Y. Hui and R. Wei, Lab Chip, 2022, 22, 2376 DOI: 10.1039/D2LC00051B

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements