Issue 25, 2015

Integrated 3D conducting polymer-based bioelectronics for capture and release of circulating tumor cells

Abstract

Here we develop a novel fabrication approach for producing three-dimensional (3D) conducting polymer-based bioelectronic interfaces (BEIs) that can be integrated on electronic devices for rare circulating tumor cell (CTC) isolation, detection, and collection via an electrically triggered cell released from chips. Based on the chemical oxidative polymerization of carboxylic acid-modified 3,4-ethylenedioxythiophene and modified poly(dimethylsiloxane) (PDMS) transfer printing technology, the high-aspect-ratio structures of poly(3,4-ethylenedioxythiophene) (PEDOT)-based “nanorod” arrays can be fabricated on indium tin oxide (ITO) electrodes when using the Si “microrod” arrays as masters. Furthermore, we integrated the biotinylated poly-(L)-lysine-graft-poly-ethylene-glycol (PLL-g-PEG-biotin) coating with 3D PEDOT-based BEIs for dynamic control of the capture/release performance of CTCs on chips; this combination exhibited an optimal cell-capture yield cells of ∼45 000 cells cm−2 from EpCAM-positive MCF7 while maintaining resistance from the adhesion of EpCAM-negative HeLa cells at a density of ∼4000 cells cm−2. By taking advantage of the electrochemical doping/dedoping properties of PEDOT materials, the captured CTCs can be triggered to be electrically released through the desorption phenomena of the PLL-g-PEG-biotin. More than 90% of the captured cells can be released while maintaining very high cell viability. Therefore, it is conceivable that the use of a 3D PEDOT-based BEI platform will meet the requirements for the development of downstream characterization of CTCs, as well as the next generation of bioelectronics for biomedical applications.

Graphical abstract: Integrated 3D conducting polymer-based bioelectronics for capture and release of circulating tumor cells

Article information

Article type
Paper
Submitted
15 janv. 2015
Accepted
08 mai 2015
First published
11 mai 2015

J. Mater. Chem. B, 2015,3, 5103-5110

Author version available

Integrated 3D conducting polymer-based bioelectronics for capture and release of circulating tumor cells

Y. Hsiao, B. Ho, H. Yan, C. Kuo, D. Chueh, H. Yu and P. Chen, J. Mater. Chem. B, 2015, 3, 5103 DOI: 10.1039/C5TB00096C

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements