Issue 7, 2023

Laboratory validation of an integrative passive sampler for per- and polyfluoroalkyl substances in water

Abstract

A passive sampler for per- and polyfluoroalkyl substances (PFAS) in water has been developed which uses a porous organosilica adsorbent. Some performance characteristics, which remained incompletely answered after prior lab- and field-based testing, were assessed. The integrated response mode of the sampler was verified in bench-scale experiments where the aqueous phase concentration was varied 50-fold in the flow across passive samplers. It was found that the passive samplers were able to accumulate analytes and provide an accurate time-averaged concentration in situations where the PFAS concentration changed significantly over time. The integrated response is facilitated by an average 40-fold slower back diffusion rate compared to PFAS adsorption rates, attributed to in-particle diffusion. The maximum deployment time was assessed using a multi-month laboratory-based sampling event. It was found that the integrated response was maintained over 90 days except for perfluorobutanoic acid (PFBA) and perfluorodecanoic acid (PFDA) where adsorption reached equilibrium after 45 and 60 days of total sampling time, respectively. The mechanism of PFAS adsorption was explored using a column breakthrough curve in combination with previously reported adsorption isotherm data. The use of isotopic dilution for PFAS measurement was studied by measuring the adsorption, recovery, and stability of mass labeled surrogates in laboratory analysis. Surrogates were quantitatively bound and determined to be stable for at least 4 weeks in the adsorbed state. Sampling rates for EPA Method 1633 compounds N-methyl perfluorooctanesulfonamidoacetic acid and N-methyl perfluorooctanesulfonamide were also measured, expanding the existing sampling rate database to a total of 21 PFAS species.

Graphical abstract: Laboratory validation of an integrative passive sampler for per- and polyfluoroalkyl substances in water

Supplementary files

Article information

Article type
Paper
Submitted
26 janv. 2023
Accepted
21 avr. 2023
First published
03 mai 2023

Environ. Sci.: Water Res. Technol., 2023,9, 1849-1861

Author version available

Laboratory validation of an integrative passive sampler for per- and polyfluoroalkyl substances in water

P. L. Edmiston, N. Hill, R. Hershberger, H. Hartmann, E. Carter and C. Divine, Environ. Sci.: Water Res. Technol., 2023, 9, 1849 DOI: 10.1039/D3EW00047H

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements