David P.
Bishop†
a,
David
Clases†
b,
Fred
Fryer
c,
Elizabeth
Williams
e,
Simon
Wilkins
f,
Dominic J.
Hare
ad,
Nerida
Cole
a,
Uwe
Karst
b and
Philip A.
Doble
*a
aElemental Bio-imaging Facility, University of Technology Sydney, Broadway, New South Wales 2007, Australia. E-mail: philip.doble@uts.edu.au; Fax: +61 2 9514 1460; Tel: +61 2 9514 1792
bInstitute of Inorganic and Analytical Chemistry, University of Münster, Münster, Germany
cAgilent Technologies, Mulgrave, Victoria, Australia
dThe Florey Institute of Neuroscience and Mental Health, The University of Melbourne, Parkville, Victoria, Australia
eAustralian Prostate Cancer Research Centre - Queensland, Institute of Health and Biomedical Innovation, School of Biomedical Sciences, Queensland University of Technology, Translational Research Institute, Brisbane, Queensland, Australia
fDepartment of Surgery, Cabrini Monash University, Malvern, Melbourne, Australia
First published on 7th September 2015
Elemental bio-imaging (EBI) of trace metal distributions in tissue sections is typically performed by laser ablation-single quadrupole-inductively coupled plasma-mass spectrometry (LA-ICP-SQ-MS) in which the sensitivity of biologically relevant elements such as Fe may be inhibited by polyatomic interferences. The triple quadrupole ICP-MS (ICP-QQQ-MS) is designed to reduce interferences and was examined for its potential application to EBI. Three tune modes; a no-gas, an H2, and an O2/H2 tune were developed and investigated for their suitability. All three performed well with high signal to noise ratios and low limits of detection. The O2/H2 tune was applied to a prostate cancer biopsy sample, with high levels of Zn found in the area correlating with the cancer. The oxygen mass shift was applied to image P and Se in a mouse brain. The unique focussing properties of the ICP-QQQ-MS and the ability to use mixed cell gases provided sensitive analyses of all measured isotopes with the O2/H2 tune, including those unaffected by mass shift reactions.
The dry plasma conditions of LA-ICP-MS have less matrix-based polyatomic species when compared against wet plasmas,15 however spectral interferences are still present for many biologically relevant trace elements (Table 1). Typical approaches for polyatomic interference mitigation with a collision/reaction cell either by kinetic energy discrimination or chemically induced dissociation16 in wet plasmas may also be applied to elemental bio-imaging, e.g. introduction of H2 gas into the reaction cell to remove the interference on 56Fe by 40Ar16O+.17 Alternatively, higher mass resolution sector-field instruments (ICP-SF-MS) are occasionally employed to resolve analytes from confounding polyatomics.18 However, ICP-SF-MS are costly, and compromises between resolution and ion transmission are required.
Isotope | Natural abundance (%) | Potential interferences |
---|---|---|
31P | 100 | 14N16O1H+, 15N15N1H+, 15N16O+, 14N17O+, 13C18O+, 12C18O1H+ |
55Mn | 100 | 40Ar14N1H+, 39K16O+, 40Ar15N+, 38Ar17O+, 36Ar18O1H+, 38Ar16O1H+ |
56Fe | 91.66 | 40Ar16O+, 40Ca16O+, 40Ar15N1H+, 38Ar18O+, 38Ar17O1H+ |
63Cu | 69.1 | 31P16O2+, 40Ar23Na+, 47Ti16O+, 23Na40Ca+, 46Ca16O1H+, 36Ar12C14N1H+, 14N12C37Cl+, 16O12C35Cl+ |
66Zn | 27.81 | 50Ti16O+, 34S16O2+, 33S16O21H+, 32S16O18O+, 32S17O2+,33S16O17O+, 32S34S+, 33S2+ |
78Se | 23.52 | 40Ar38Ar+, 38Ar40Ca+ |
80Se | 49.82 | 40Ar2+, 32S16O3+ |
The recently-introduced triple quadrupole ICP-MS (ICP-QQQ-MS) is designed to mitigate interferences in a number of ways.19 The geometry consists of three mass filters. In MS/MS mode the first quadrupole (Q1) filters the mass-to-charge ratio (m/z) of interest prior to introduction into an ion-guide (Q2), which can be filled with a collision and/or reaction gas. The final quadrupole (Q3) again filters the desired analyte, either on its original mass or the mass shift of a known reaction product.20 In bandpass mode, ion transmission through Q1 may be manipulated by varying the scan line slope (SLS) and scan line gain (SLG) factors.20
The ICP-QQQ-MS has been applied to analytes that are difficult to detect at low concentrations by ICP-SQ-MS, including phosphorus (P), sulfur (S) and silicon (Si) in organic matrices.21 Oxygen (O2) may be reacted with these kinetically-favoured analytes to form an MO+ mass that is filtered by Q3, removing all other interfering species. This approach had superior detection limits when compared against isotope dilution (ID) – ICP-SF-MS.21 The O+ mass shift method has also been used to determine metals and heteroatoms in a range of biological, environmental and organic matrices.22–26 Further, the ability of some elements to form an asymmetric charge transfer species in the presence of O2, leading to the detection of 16O2+ adducts has been exploited to overcome particularly difficult isobaric interferences;27 while others have relied on the formation of adducts such as Ti(NH3)6+ or used N2O in the reaction for this purpose.28,29
Here, we describe the first use of an ICP-QQQ-MS in elemental bio-imaging to improve the detection of elements that are subject to potential interferences in biological tissues via mass-shift whilst maintaining the detection sensitivity of on-mass analytes. We have evaluated three tune conditions with matrix matched standards to determine effects on the limits of analysis. The mass shift tune was then applied to examine biologically significant elements in histological sections of mouse brain and prostate cancer biopsy material.
In order to use these tunes for laser ablation, S-lenses were used to increase the ion throughput and the sensitivity. Integration times were adapted to the spot size and scan speed as determined by Lear et al.17 The change from wet-plasma conditions to dry-plasma conditions required further fine tuning adjustments, which were performed with the ablation of the NIST 612 Trace Element in Glass reference standard. The final tune parameters are shown in Table 2 and were used for all further experiments described.
O2 | H2 and no gas | |
---|---|---|
Deflector potential | −11 V | 3 V |
Energy discrimination potential | −6.1 V | 4 V |
Octopole bias | −16.9 V | −20 |
O2 gas flow | 0.56 mL min−1 | 0 mL min−1 |
H2-gas flow | 1.1 mL min−1 | 3 mL min−1 or 0 mL min−1 |
The no-gas and H2 tunes were optimised using bandpass mode. The H2 cell gas flow rate was 3 mL min−1. An SLS-factor variation was performed to maximise sensitivity and minimise background equivalent concentration (BEC). The BEC was calculated according to eqn (1).
(1) |
The relative performance of each of these tune conditions was investigated by construction of calibration curves following laser ablation of matrix matched standards.
The standards of all relevant biometals were prepared at concentrations of biological significance.32 Four 4 mm lines of each standard were ablated to construct the calibration curves (see Table 3). The data was averaged for each calibration level. This analysis was performed in triplicate and the calibration curve was constructed with all three data points for each standard level as an input. The LINEST function in Microsoft Excel was used to determine the standard deviation of the y-intercept.
Level | Mn | Fe | Cu | Zn | Se |
---|---|---|---|---|---|
1 | 0.0304 | 14.8 | 5.42 | 2.29 | 0.00 |
2 | 0.528 | 13.7 | 5.49 | 4.17 | 0.0503 |
3 | 10.0 | 36.6 | 15.9 | 18.1 | 6.77 |
4 | 1.89 | 47.7 | 24.3 | 27.9 | 0.921 |
5 | 44.4 | 89.9 | 51.9 | 64.5 | 34.2 |
Animals were euthanased with an overdose of sodium pentobarbitone (100 mg kg−1) and perfused with 30 mL of warmed (37 °C) 0.1 M phosphate buffered saline (PBS), pH 7.4. Tissue was briefly fixed in 4% paraformaldehyde in PBS until the brains sank (for complete fixation of tissue), after which they were immersed overnight in two changes of 30% sucrose in PBS (to provide cryoprotection before cryosectioning).33 Tissue was then frozen at −80 °C and mounted in O.C.T.™ via the medulla oblongata and upper spinal cord. After equilibrating at −20 °C, the brains were sectioned using PTFE-coated cryotome blades to 30 μm thickness at 90 μm intervals and mounted on standard microscope slides.
Collection of human tissue was conducted with ethical approval of the St. Vincent's Hospital Human Ethics Committee and were in accordance with Australian National Health and Medical Research Council Guidelines. Formalin fixed, paraffin embedded sections (30 μm) were obtained from a radical prostatectomy sample. Histopathological assessment revealed Gleason grade 3 + 3 prostatic adenocarcinoma with focal extracapsular extension, clear margins, and no seminal vesicle involvement.
Tune 1 (no-gas) served as a reference tune for comparison against tunes 2 and 3. In typical ICP-SQ-MS, attempts to increase sensitivity by increasing ion transmission results in concomitant increases in interfering polyatomic signals. In contrast, the QQQ configuration removes the confounding signals with increasing ion transmission by exploitation of collisions and reactions in Q2, followed by further mass filtering in Q3. Tune 2 (H2) was performed in bandpass mode which allowed manipulation of ion transmission through Q1 by varying the SLS and SLG parameters. Changing the SLG factor from 0.4 to 0.9 did not result in significant changes of sensitivity and was maintained at 0.9 for all further experiments. Fig. 1 shows a plot of sensitivity and BEC vs. SLS factor for copper.
All other target elements had similar profiles. The SLS factor had minimal impact on sensitivity and BEC between 0.5 and 0.7, and a marked decrease in sensitivity and increase in BEC between 0.7 and 0.8. A SLS factor of 0.7 and a SLG factor of 0.9 gave the maximum sensitivity and minimum BEC and were used for all further experiments. Tune 3 was performed in MS/MS mode which had fixed values of SLG and SLS to pass specified ions of interest to the reaction cell (Q2) prior to further filtering and detection in Q3. This tune mode was suitable for detecting on-mass or mass-shift ions for kinetically favoured reactions. All elements other than P and Se were monitored on-mass. Although Se has a small positive reaction enthalpy (Se+ + O → SeO+δ 0.69 eV), we have previously shown in solution analysis that the SeO+ reaction is kinetically favoured.23
LODs μg g−1 | LOQs μg g−1 | |||||
---|---|---|---|---|---|---|
No-gas | H2 | O2/H2 | No-gas | H2 | O2/H2 | |
55Mn | 0.55 | 0.20 | 0.35 | 1.8 | 0.67 | 1.2 |
56Fe | 2.3 | 2.3 | 2.7 | 7.6 | 7.7 | 9 |
63Cu | 1.4 | 1.8 | 1.0 | 4.7 | 6.0 | 3.4 |
66Zn | 1.8 | 3.6 | 2.5 | 6.1 | 11.9 | 8.4 |
78Se | 0.93 | 0.31 | 1.2 | 3.1 | 1.0 | 4.0 |
80Se | — | 0.44 | 0.55 | — | 1.5 | 1.8 |
Small differences in LOD and LOQ were apparent across all of the tunes. The no-gas tune provided similar or better performance for ions free from gas contaminant interferences (63Cu and 66Zn) when compared against the other tunes. This indicated that mitigation of confounding signals with either reaction or mass shift had a minimal effect on the signal.
Adjusting the bandpass settings in the no-gas and H2 tunes allowed more ions to be transmitted than traditionally occurs with ICP-SQ-MS, leading to increased backgrounds in the no-gas tune. However, addition of H2 eliminated these increases and improved the detection limits for 55Mn, 78Se, 80Se whilst 56Fe remained the same. This is consistent with our previous reports of LOD improvement with H2 tunes with a ICP-SQ-MS.17 The mass shift tune resulted in a similar detection limit for 80Se when compared against H2.
A prostate cancer tissue biopsy with a Gleason Score of 6 (3 + 3), which represented a mid-range score assigned by the American Society of Clinical Oncology,35 in which the cells remain well differentiated, is shown in Fig. 2. This image was obtained with the mass shift tune in order to demonstrate that both on-mass and mass shift analytes may be detected. High levels of Zn were observed in the tissue and gave clear delineation of the histologically observed margins of the tumour. These findings are consistent with known upregulation of a number of Zn-rich proteins such as Zn-transporter proteins, ZIP9 and ZEB36,37 and suggesting that Zn or other elemental distributions may be able to provide a useful marker for augmenting current histological grading of prostate cancers. The levels of Se remained at or below the limits of detection even using the O2/H2 mass shift tune.
Selenium has long been refractory to analysis by EBI. The detection of the two major isotopes, 80Se and 78Se, are confounded by polyatomic argon dimers, which are present in a large abundance. The mass shift from m/z 80 to m/z 96 effectively moved the Se signal away from the interferences, revealing a Se image of a mouse brain section (Fig. 3(a)). In the majority of applications of LA-ICP-MS, Se quantification is attempted after separation by gel electrophoresis separation, and pre-concentration of the selenoproteins.38–44 Se has previously been imaged in mouse models exposed to Cd–Se quantum dots with 82Se monitored,45 and via the O-mass shift on 80Se in sunflower leaves grown in a high Se matrix with a ICP-SQ-MS.46 However, mass shift products obtained with an ICP-SQ-MS are still subject to spectral interferences that are not present with ICP-QQQ-MS due to mass filtering in Q1; for example 96Mo, 96Ru, 96Zr, 39K41K16O+, 79Br17O+.
Fig. 3 (a) 80Se → 80Se16O image and (b) 31P → 31P16O image of a mouse brain obtained with LA-ICP-QQQ and an O2/H2 tune. |
Although dry plasmas used with LA-ICP-MS are not subjected to the same level of polyatomic formation as that of a traditional wet plasma with solution nebulisation,47 monoisotopic phosphorus is subject to polyatomic interferences from common gas contaminants such as N2 and O2. The P → PO mass shift is demonstrated in Fig. 3(b). The mass shift effectively removed interferences resulting in backgrounds of approximately 100 cps compared to approximately 2600 cps with LA-ICP-SQ-MS with the H2 tune.
The O2/H2 tune was performed in MS/MS mode and was effective in mass-shifting the signals of P and Se, whilst maintaining sensitive detection of other elements. A prostate cancer biopsy and mouse brain was run with the O2 tune. A high level of Zn was identified in the cancerous tissue and phosphorus (P) was readily converted to PO in the mouse brain. The S → SeO mass shift was effective for analysis of 80Se, the most abundant Se isotope, without the need to account for other spectral interferences on m/z 96.
Footnote |
† These authors contributed equally. |
This journal is © The Royal Society of Chemistry 2016 |