Issue 11, 2024

High-sensitivity detection of low-concentration heavy metal ions in solution by multiple reflection enhanced absorption (MREA) spectroscopy

Abstract

Heavy metal ions (Cr6+, Co2+, Ni2+, and Cu2+) in the electroplating and electrolysis industries are significantly related to process parameters and product quality, even at lower concentrations. Absorption spectroscopy is widely used for substance qualitative and quantitative analysis, which is an analytical method with the potential for real-time monitoring of heavy metal ions concentration in industrial processes. In this paper, a low-concentration heavy metal ion analysis method based on multiple reflection enhanced absorption (MREA) is proposed. Compared with traditional absorption, MREA has the advantages of low concentration detection limit and high-sensitivity. First, a reflective film (Al–SiO2) was prepared and a multiple reflection optical structure was designed to realize multiple parallel reflections of light in the solution medium. Then absorption spectra of low-concentration Cr6+, Co2+, Ni2+ and Cu2+ solutions were measured by MREA and traditional absorption methods. Finally, spectral bandwidth and incident light spots were optimized to obtain a superior absorption enhancement effect. The results showed that MREA could effectively increase the substance absorbance compared with traditional absorption. At the same time, with the optimal spectral bandwidth (0.4 nm) and incident light spot (1 mm), the detection limit of Cr6+, Co2+, Ni2+ and Cu2+ was reduced by 81.48%, 82.52%, 80.92% and 82.93%, respectively. The sensitivity was improved by 5–6 times, which was more obvious for low-concentration detection. In addition, the MREA method can achieve ion concentration analysis when Cr6+, Co2+, Ni2+, and Cu2+ coexist, and the linear correlative coefficients of the CA curves were all greater than 0.999. Moreover, by adjusting reflectivity of the reflective film and the number of reflections in the optical structure, the results of the MREA method can be further optimized for the low-concentration heavy metal ion analysis. The MREA method has the advantages of simplicity, rapidity and versatility, which can provide the technical foundation for real-time monitoring method development of low-concentration heavy metal ions in industrial processes.

Graphical abstract: High-sensitivity detection of low-concentration heavy metal ions in solution by multiple reflection enhanced absorption (MREA) spectroscopy

Supplementary files

Article information

Article type
Paper
Submitted
28 Nov 2023
Accepted
10 Jan 2024
First published
29 Feb 2024

Anal. Methods, 2024,16, 1674-1685

High-sensitivity detection of low-concentration heavy metal ions in solution by multiple reflection enhanced absorption (MREA) spectroscopy

R. Zhang, H. Liu, L. Jiang, N. Duan, F. Xu, W. Gao, Y. Liu, G. Zhu and J. Wang, Anal. Methods, 2024, 16, 1674 DOI: 10.1039/D3AY02117C

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements