Issue 2, 2014

Hollow-fiber membrane tube embedded with a molecularly imprinted monolithic bar for the microextraction of triazine pesticides

Abstract

A molecularly imprinted polymer (MIP) monolith was initially prepared in a silica capillary mold by microwave irradiation. After the silica wall was etched away after polymerization, the resulting monolithic bar was embedded in a porous hollow fiber membrane tube (HFMT), in which a thin supported liquid membrane (SLM) was formed in the pores and an acceptor solution was filled in its lumen. It can be used to overcome the common water-compatibility problem in the MIP application by the developed hollow fiber–liquid–solid microextraction (HFLSME) system. The main factors affecting the selective extraction including extraction and desorption time, extraction solvent in the hollow fiber (HF) lumen, off-line desorption solvent, stirring rate and pH of the sample solution were investigated for HFLSME procedures in detail. Selectivity was also evaluated using the atrazine template molecule, its analogues and non-analogue. The extraction amount for each structurally-related pesticide including atrazine, 2-amino-4-methoxy-6-methyl-1,3,5-triazine, terbutylazine and ametryn was obtained about 10 times using atrazine-imprinted hollow fiber than that using non-imprinted hollow fiber, whilst no obvious difference was found for its non-analogues of metribuzin. The resulted hollow fibers were successfully applied to detect atrazine and its analogues in lake water coupled to high performance liquid chromatography (HPLC) and resulted in recoveries in the range of 72.8–113.2%, respectively.

Graphical abstract: Hollow-fiber membrane tube embedded with a molecularly imprinted monolithic bar for the microextraction of triazine pesticides

Article information

Article type
Paper
Submitted
24 Aug 2013
Accepted
29 Oct 2013
First published
29 Oct 2013

Anal. Methods, 2014,6, 602-608

Hollow-fiber membrane tube embedded with a molecularly imprinted monolithic bar for the microextraction of triazine pesticides

J. Chen, L. Bai, M. Tian, X. Zhou and Y. Zhang, Anal. Methods, 2014, 6, 602 DOI: 10.1039/C3AY41455H

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements