Issue 7, 2014

Rapid, in situ detection of cocaine residues based on paper spray ionization coupled with ion mobility spectrometry

Abstract

In this paper, a novel approach based on paper spray ionization coupled with ion mobility spectrometry (PSI-IMS) was developed for rapid, in situ detection of cocaine residues in liquid samples and on various surfaces (e.g. glass, marble, skin, wood, fingernails), without tedious sample pretreatment. The obvious advantages of PSI are its low cost, easy operation and simple configuration without using nebulizing gas or discharge gas. Compared with mass spectrometry, ion mobility spectrometry (IMS) takes advantage of its low cost, easy operation, and simple configuration without requiring a vacuum system. Therefore, IMS is a more congruous detection method for PSI in the case of rapid, in situ analysis. For the analysis of cocaine residues in liquid samples, dynamic responses from 5 μg mL−1 to 200 μg mL−1 with a linear coefficient (R2) of 0.992 were obtained. In this case, the limit of detection (LOD) was calculated to be 2 μg mL−1 as signal to noise (S/N) was 3 with a relative standard deviation (RSD) of 6.5% for 11 measurements (n = 11). Cocaine residues on various surfaces such as metal, glass, marble, wood, skin, and fingernails were also directly analyzed before wiping the surfaces with a piece of paper. The LOD was calculated to be as low as 5 ng (S/N = 3, RSD = 6.3%, n = 11). This demonstrates the capability of the PSI-IMS method for direct detection of cocaine residues at scenes of cocaine administration. Our results show that PSI-IMS is a simple, sensitive, rapid and economical method for in situ detection of this illicit drug, which could help governments to combat drug abuse.

Graphical abstract: Rapid, in situ detection of cocaine residues based on paper spray ionization coupled with ion mobility spectrometry

Supplementary files

Article information

Article type
Paper
Submitted
26 Nov 2013
Accepted
08 Jan 2014
First published
08 Jan 2014

Analyst, 2014,139, 1687-1691

Rapid, in situ detection of cocaine residues based on paper spray ionization coupled with ion mobility spectrometry

M. Li, J. Zhang, J. Jiang, J. Zhang, J. Gao and X. Qiao, Analyst, 2014, 139, 1687 DOI: 10.1039/C3AN02198J

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements