Issue 4, 2000

Abstract

A field study was conducted with the goal of comparing the performance of three recently developed or modified sampling and analytical methods for the determination of airborne hexavalent chromium (CrVI). The study was carried out in a hard chrome electroplating facility and in a jet engine manufacturing facility where airborne CrVI was expected to be present. The analytical methods evaluated included two laboratory-based procedures (OSHA Method ID-215 and NIOSH Method 7605) and a field-portable method (NIOSH Method 7703). These three methods employ an identical sampling methodology: collection of CrVI-containing aerosol on a polyvinyl chloride (PVC) filter housed in a sampling cassette, which is connected to a personal sampling pump calibrated at an appropriate flow rate. The basis of the analytical methods for all three methods involves extraction of the PVC filter in alkaline buffer solution, chemical isolation of the CrVI ion, complexation of the CrVI ion with 1,5-diphenylcarbazide, and spectrometric measurement of the violet chromium–diphenylcarbazone complex at 540 nm. However, there are notable specific differences within the sample preparation procedures used in three methods. To assess the comparability of the three measurement protocols, a total of 20 side-by-side air samples were collected, equally divided between a chromic acid electroplating operation and a spray paint operation where water soluble forms of CrVI were used. A range of CrVI concentrations from 0.6 to 960 ”g m−3, with CrVI mass loadings ranging from 0.4 to 32 ”g, was measured at the two operations. The equivalence of the means of the log-transformed CrVI concentrations obtained from the different analytical methods was compared. Based on analysis of variance (ANOVA) results, no statistically significant differences were observed between mean values measured using each of the three methods. Small but statistically significant differences were observed between results obtained from performance evaluation samples for the NIOSH field method and the OSHA laboratory method.

Article information

Article type
Paper
Submitted
28 Mar 2000
Accepted
21 Jun 2000
First published
06 Jul 2000

J. Environ. Monit., 2000,2, 329-333

Comparison of three sampling and analytical methods for the determination of airborne hexavalent chromium

J. M. Boiano, M. E. Wallace, W. Karl Sieber, J. H. Groff, J. Wang and K. Ashley, J. Environ. Monit., 2000, 2, 329 DOI: 10.1039/B002456M

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Spotlight

Advertisements