Open Access Article
Torsten Wieduwilta,
Matthias Zeisbergera,
Walter Hauswald
a,
Adrian Lorenza,
Shayan Vazirieh Lenjanib,
Christian Rossner
bcd and
Markus A. Schmidt
*aef
aLeibniz Institute of Photonic Technology, Albert-Einstein-Str. 9, 07745 Jena, Germany. E-mail: markus-alexander.schmidt@uni-jena.de
bLeibniz Institute of Polymer Research Dresden, Hohe Straße 6, 01069 Dresden, Germany
cFaculty of Chemistry and Food Chemistry, Technische Universität Dresden, Bergstrasse 6, 01069 Dresden, Germany
dDepartment of Polymers, University of Chemistry and Technology Prague, Technická 5, 16628 Prague 6, Czech Republic
eOtto Schott Institute of Material Research, Friedrich Schiller University Jena, Fraunhoferstr. 6, 07743 Jena, Germany
fAbbe Center of Photonics and Faculty of Physics, Friedrich Schiller University of Jena, Max-Wien-Platz 1, Jena 07743, Germany
First published on 16th June 2026
Understanding nanoparticle interactions at the nanoscale is essential for numerous scientific fields and applications, with waveguide-based approaches offering a promising solution. In this work, we present a fiber-integrated platform for nanoparticle tracking analysis based on a fiber-type capillary structure (hereinafter referred to as “capillary”) that achieves high performance comparable to more complex microstructured fibers. By combining measurements with optical simulations, we validate light propagation and loss behavior in water-filled capillaries, showing excellent agreement with theoretical predictions. The capillary-based approach provides structural simplicity, robustness, and compatibility with fiber systems, while enabling diffraction-limited imaging and accurate determination of hydrodynamic diameters for mono- and polydisperse nanoparticle ensembles. The demonstrated platform may serve as a future foundation for the characterization of nanoscale species in confined geometries and could be relevant for applications in nanoscience, bioanalytics, and environmental analysis.
In addition to the NTA method, a range of diffusion-based techniques have been developed to determine the hydrodynamic diameter of NPs, which can be broadly divided into two groups: (i) approaches that require fluorescent labeling, such as microfluidic diffusional sizing (MDS),1 nanofluidic diffusional sizing (NDS)2 and fluorescence correlation spectroscopy (FCS),3 and (ii) label-free techniques, including dynamic light scattering (DLS),4 interferometric scattering microscopy (iSCAT)5 and Taylor dispersion analysis (TDA)6,7 (see SI, sec. S1 for details).
One promising NTA approach introduced in recent years is fiber-assisted NTA (FaNTA).8 Here NPs diffusing in a liquid-filled microchannel along an optical fiber are illuminated by the modal field and the trajectories are obtained from the sidewise scattered light. In addition to fast imaging and compatibility with fiber and microfluidic systems, FaNTA's key advantage is the confinement of diffusing NPs within the illuminated volume and focal plane, enabling exceptionally long trajectories of fast-diffusing objects and highly accurate size determination.
Various FaNTA-related experiments have been reported, including 3D tracking in modified step-index fibers,9 or the observation of previously unknown optical modes.10 A particularly promising approach involves fibers with anti-resonant elements, enabling core diameters in the tens of micrometers range. This reduces confinement effects and enables the parallel tracking of hundreds of NPs.
In addition to hollow-core fibers,11 the current state-of-the-art FaNTA platform is based on fibers with a single anti-resonant element (1-ARE). Here, light is guided inside a thin glass annulus attached to the inner wall of a support capillary. This platform has been used to assess the polydispersity of polystyrene nanoparticles12 and to track gold nanoparticles as small as 9 nm.13 The concept has also been extended to nanoprinted hollow-core waveguides on silicon chips14 and fiber end faces.15
Despite their effectiveness, 1-ARE fibers have several limitations, including complex fabrication to achieve homogeneous membrane thicknesses over extended lengths, the need for precise geometric alignment during measurements, and degraded optical imaging caused by multiple curved interfaces in the microscopic path.
A promising alternative are single-interface capillaries, which represent a concentric arrangement of a low-index circular channel (core) surrounded by an infinitely extended high-index medium. As the simplest form of microstructured fiber, capillaries are straightforward to fabricate, offer perfect azimuthal symmetry, and minimize the number of transverse interfaces – favorable properties for NTA. Note that since light guidance in capillaries is governed by Fresnel reflection, they exhibit higher losses than anti-resonant hollow-core fibers, which principally can be mitigated by inner-wall coatings.16
In this work, we investigate the use of fiber-type capillaries for waveguide-based NTA by combining optical simulations, loss measurements, and particle tracking experiments on gold and polystyrene NP ensembles (Fig. 1).
![]() | ||
| Fig. 1 Illustration of light guidance in a water-filled capillary used for nanoparticle tracking analysis (green: guided light, bright green: diffusing nanoparticles, light gray: capillary). | ||
We characterize modal losses in water-filled capillaries, evaluate imaging performance through ray-tracing simulations, and demonstrate particle tracking using an image-based analysis workflow. The results are benchmarked against microstructured fibers (1-ARE fibers), to assess the performance of the capillary platform.
![]() | (1) |
Using experimentally relevant parameters (λ0 = 532 nm, nwater (20 °C, 532 nm) = 1.3354,19 nsilica (532 nm) = 1.4607 (ref. 20)), eqn (1) predicts losses for the fundamental HE11 mode in a water-filled capillary of 2.6 dB cm−1 < γ < 11.9 dB cm−1 for microchannel diameters 25 μm > dc > 15 μm (Fig. 2).
These values are significantly higher than those of comparable annular structures (e.g. 1-ARE fibers). Notably, higher-order modes exhibit substantially greater losses, highlighting the relevance of the fundamental mode.
The NTA experiments involve recording the diffusive motion of a NP ensemble in water by microscopically imaging the laterally scattered light and statistically analyzing the individual trajectories using mean-square displacement (MSD) analysis. The diffusion coefficient D of each NP is extracted from the slope of its MSD curve and converted into the hydrodynamic diameter dh using the Stokes–Einstein relation, taking into account the viscosity of water21 (see SI, sec. S3). The mean hydrodynamic diameter of the ensemble is computed by weighting each hydrodynamic diameter by its trajectory length (unit: frames) and dividing the sum of all weighted diameters by the total number of frames across all trajectories. In addition, the coefficient of variation (CV = σ/μ, with σ as the standard deviation and μ as the mean value) is calculated to quantify the precision of this statistically limited measurement method. Trajectories were extracted using the Python package Trackpy (see SI, sec. S4). Note that the accuracy of the diffusion coefficient obtained from MSD analysis increases with the number of frames per trajectory.12 To further enhance the statistical significance of the results, complex data processing was performed, including z-score filtering and corrections for the effect of transversely restricted diffusion (see sec. S4 of the SI).
Losses were determined by measuring the side-scattered light along the water-filled capillary over a distance of (8–10) mm, with the fiber translated under the microscope in 1 mm steps. To achieve sufficient signal intensity, an exposure time of 1 s was used with a laser power of 120 mW at the butt-coupling interface. As an example of the measurement results, Fig. 4 shows selected images of the sidewise emitted light from a capillary with a channel diameter of dc = 17.8 μm recorded at different longitudinal positions. A clear decrease in intensity with increasing distance from the capillary entrance is observed, reflecting the transmission losses due to Fresnel reflection at the core-cladding interface.
Based on these images, the longitudinal intensity profile along the center of the water-filled core – i.e., the middle of the bright regions of the images – was extracted. Fig. 5(a) displays the combined profiles, with each color corresponding to data from a single image, clearly showing a decrease in intensity with increasing distance from the capillary input. Note that as the step size (1 mm is smaller than the captured image length (1.41 mm), the intensity profiles partially overlap. A linear curve (white line in Fig. 5(a)) was applied to the data, and the resulting slope was used to determine the modal loss.
![]() | ||
| Fig. 5 (a) Intensity distribution of side-scattered light from a water-filled capillary (dc = 17.8 μm, capillary B) along a total length of 8 mm, resulting from evaluating the images shown in Fig. 4 each color represents a different distance from the capillary input (cf. Fig. 4). The dashed white line indicates the slope corresponding to modal loss. (b) Comparison of theoretically (solid line) and experimentally (red points) determined modal loss of water-filled capillaries as a function of channel diameter in the range of 15 μm < dc < 25 μm. | ||
Using this procedure, the loss of four selected capillaries with different channel diameters (Table 1) were determined and compared with theoretical predictions (Fig. 5(b)). The experimental results show excellent agreement with the theoretical curve, confirming both the validity of the model and the high quality of the fabricated capillaries. The slightly elevated measured values may be caused by the excitation of higher-order modes, which exhibit greater losses (Fig. 2).
| Parameter | Capillary A | Capillary B | Capillary C | Capillary D |
|---|---|---|---|---|
| Core diameter [μm], SEM | 15.5 ± 0.1 | 17.8 ± 0.05 | 20.9 ± 0.3 | 24.8 ± 0.05 |
| Loss (theory) [dB cm−1] | 10.8 ± 0.2 | 7.05 ± 0.05 | 4.40 ± 0.2 | 2.60 ± 0.02 |
| Loss (experiment) [dB cm−1] | 11.3 ± 0.1 | 7.30 ± 0.1 | 5.40 ± 0.1 | 3.00 ± 0.10 |
It is important to note that slight periodic intensity modulations are observed in capillaries with large channel diameter, caused by weak excitation of the HE12 higher-order mode and the resulting beating with the fundamental mode. This excitation arises from the mismatch between the Bessel-like mode profile of the capillary and the Gaussian mode of the delivery fiber (more details in SI, sec. S6). The resulting interference leads to periodic intensity variations along the capillary, which, however, are practically negligible due to the high loss of the HE12 mode. The exposure time used in the loss experiments are about 500 times longer than in the actual NTA experiments, making the contribution of light scattered by the water negligible in the NTA measurements.
A water-filled capillary with a channel diameter of dc = 16 μm (γ ≈ 10 dB cm−1 at λ0 = 532 nm) was selected for the FaNTA experiments (Fig. 2 and 6(a)). This diameter was chosen to match the depth of field of the microscope objective (Olympus Plan N 10 × 0.25) used for particle detection, avoiding deterioration in image quality when the NP approaches the top or bottom of the microchannel. For comparison, the selected 1-ARE fiber featured a channel diameter of dc = 16.6 μm (Fig. 6(b)), closely matching that of the capillary. Note that a membrane thickness of 700 nm was chosen for the ARE to ensure low-loss guidance at λ0 when the fiber is filled with water. The choice of the comparably short excitation wavelength of λ0 = 532 nm is optimal for 28 nm gold NPs due to the plasmonically enhanced scattering cross-section, while also being well suited for tracking dielectric particles.
The experimental setup (Fig. 3) was identical to that used for the loss measurements, with adjusted image acquisition parameters (frame rate 450 fps and exposure time 1.95 ms). The optical power was kept sufficiently low (≈40 mW in case of the capillary) in order to prevent any light-induced heating effects.13 Accurate determination of trajectories and hydrodynamic diameters requires aberration-free imaging to minimize localization errors – a key challenge in NTA generally (details on the effects of misalignment, see sec. S8 of the SI). Details regarding the effects of the frame rate, observation time, exposure time, and nanoparticle concentration are included in the SI, sec. S5.
Fig. 7 shows the distribution of hydrodynamic diameters from eight consecutive measurements (colored dots), determined via MSD analysis for both fiber types (top row: 1-ARE fiber, bottom row: capillary; benchmark values in Table 2). Note that the number of detected trajectories exceeds the actual number of NPs, due to intersecting trajectories or temporary loss of visibility when particles approach the channel wall and shows reduced scattering intensity. To ensure statistical significance, only trajectories with a minimum length of 300 frames were included in the analysis (vertical dashed grey lines in Fig. 7(a and c).
| Measurement method | Mean hydrodynamic diameter [nm] | CV | Standard deviation of the distribution [nm] |
|---|---|---|---|
| DLS (manufacturer) | 36 | Not specified | Not specified |
| FaNTA with 1-ARE-fiber | 33.8 ± 0.7 | 0.093 ± 0.014 | 3.1 ± 0.5 |
| FaNTA with capillary | 35.3 ± 0.9 | 0.095 ± 0.010 | 3.4 ± 0.4 |
The experiments demonstrate that the mean hydrodynamic diameters (blue dashed lines in Fig. 7) obtained from both fiber-based systems closely match each other and agree well with DLS reference measurements (Table 2), confirming the suitability of capillaries as a platform for NTA.
The strong agreement between the two FaNTA results is particularly noteworthy, given that two different NP ensembles were measured. The slightly smaller diameters observed in the FaNTA experiments compared to DLS may be attributed to the approximately 2300-fold dilution of the NP stock solution required for FaNTA, which could have led to partial detachment of PEG ligands from the NP surface. Comparable CV values for both fiber types further support the reliability and applicability of the capillary-based FaNTA approach.
:
1 mixture of polystyrene NPs (Thermo Fisher Scientific Inc.) with physical diameters of (100 ± 4) nm (specie 3100A) and (122 ± 3) nm (specie 3125A). Experimental details including measurements of monodisperse solutions are provided in sec. S9 of the SI. Note that this mixture consists of the same particle types that were used in our previous work (M. Nissen et al.12 addressing FaNTA in a 1-ARE fiber.As shown in Fig. 8, the capillary-based approach enables a clear distinction between the two NP populations in terms of their hydrodynamic diameters. Notably, some particles exhibit trajectory lengths of up to 11
000 frames, indicating that they remained trackable over 27.5 s, representing an exceptionally long observation time in the context of NTA.
As summarized in Table 3, the hydrodynamic diameters obtained for the NP mixture are in very good agreement with those measured for the corresponding monodisperse samples. In addition, the observation that the particle solution with the larger nominal diameter (3125A) exhibits a slightly narrower diameter distribution (lower CV value) is confirmed by our FaNTA measurements and is consistent with the manufacturer's TEM specifications. The results are also in good agreement with those reported by M. Nissen et al.12
:
1 mixture. Note that in the DLS measurements the two components in the mixture measurements could not be resolved; therefore, no mean hydrodynamic diameters can be reported for the mixed sample
| Measurement method | Parameter | Monodisperse sample | NP mixture | ||
|---|---|---|---|---|---|
| 3100A | 3125A | 3100A | 3125A | ||
| FaNTA, capillary [this work] | Mean hydr. diam. [nm] | 110.3 ± 0.2 | 132.8 ± 0.3 | 110.4 ± 0.3 | 133.6 ± 0.4 |
| CV [%] | 5.9 | 5.7 | 6.5 | 4.2 | |
| FaNTA, 1-ARE [Nissen et al.] | Mean hydr. diam. [nm] | 107.9 ± 0.1 | 132.8 ± 0.3 | 111.3 | 134.3 |
| DLS [Nissen et al.] | Mean hydr. diam. [nm] | 108.7 ± 0.5 | 131.4 ± 0.8 | N.A. | N.A. |
With a collapsed polymer shell, this type of NPs remain colloidally stable at low ionic strength due to electrostatic stabilization. In the case of high ionic strength achieved by adding electrolytes, electrostatic screening reduces interparticle repulsion and induces NP clustering.24,25 Details of the sample preparation and the thermo-responsive behavior are provided in sec. S10 of the SI.
Fig. 9(b) shows the trajectory-length-weighted histograms in case a precise amount of electrolytes are added to the NP solution: At lower temperature (green), the distribution exhibits a narrow, single-peak profile centered around approximately 60 nm. This reflects the hydrated, expanded coil state of the polymer shell below the LCST, where the NPs remain well dispersed. In contrast, at elevated temperature (red), the distribution shifts significantly toward larger hydrodynamic diameters and broadens markedly. The appearance of particles with diameters extending beyond 150 nm clearly indicates temperature-induced cluster formation. The pronounced broadening of the distribution demonstrates the transition from a predominantly monodisperse suspension to a polydisperse ensemble of aggregates upon heating above the LCST. Thus, supracolloidal assembly processes induced by external stimuli can be effectively captured and resolved using capillary-based FaNTA.
From the spot diagrams in Fig. 10(b and c), it is evident that for NPs positioned in the focal plane (center of the capillary channel), all rays fall within the airy disk diameter, confirming diffraction-limited imaging (an overview of the key performance indicators can be found in Table 4). This is supported by the small RMS (root mean square) value of the ray distribution (≈5.2 μm), which is well below the airy disk diameter (26 μm). Particles outside the focal plane (Fig. 10(a and d)) show a broadened distribution, as evident in Fig. 10(a) for the top position, where the particle is located 7.5 μm from the focal plane (0.5 μm from the capillary wall). Although some rays extend beyond the airy disk diameter, the RMS value remains below it, confirming diffraction-limited imaging even in this scenario. These findings demonstrate that the configuration investigated here maintains diffraction-limited optical resolution with negligible aberrations. The primary effect observed is minor defocusing at the top and bottom positions, which does not affect tracking since NP positions are determined by fitting the scattered light intensity profile to locate the centroid. Simulations also reveal that for capillaries with inner diameters greater than 20 μm, the RMS value for NP located more than 7.5 μm from the focal plane may exceed the airy disk diameter, resulting in imaging that is no longer diffraction-limited (see Table 4).
| Position | Top | Center | Side | Bottom | |
|---|---|---|---|---|---|
| Type of fiber | (x, y, z) [μm] | (0, 0, 7.5) | (0, 0, 0) | (0, ±7.5, 0) | (0, 0, −7.5) |
| Capillary (16 μm) | 20.00 | 5.15 | 5.20 | 18.97 | |
| 1-ARE fiber (16 μm) | 20.71 | 4.64 | 4.69 | 20.33 |
| (x, y, z) [μm] | (0, 0, 12) | (0, 0, 0) | (0, ±12, 0) | (0, 0, −12) | |
|---|---|---|---|---|---|
| Capillary (25 μm) | 31.42 | 5.27 | 5.46 | 29.65 | |
| 1-ARE fiber (25 μm) | 32.44 | 4.70 | 4.79 | 31.72 |
Based on the signal-to-noise ratio of the measurement on 28 nm gold NPs and the corresponding scattering cross-section (27 nm2), we estimate the smallest detectable diameter of gold NPs, using a capillary, to be approximately 15 nm. Results of the experimental verification of this estimate are presented in the SI, sec. S11.
The experiments showed that this requires the use of capillaries with larger inner diameter (e.g. a 25 μm capillary with γ ≈ 2.6 dB cm−1), detection as close as possible to the capillary input, and a laser power of at least 130 mW at the capillary input.
Unlike gold nanoparticles, dielectric particles have a significantly smaller scattering cross-section due to their lower refractive index contrast and the absence of plasmon resonances, resulting in a larger minimum detectable diameter. In case of polystyrene NPs (nD ≈ 1.6) in water, this corresponds to a diameter limit of about 40 nm. Detection of smaller NPs requires 1-ARE fibers, which offer lower loss and higher SNR, enabling characterization of gold NPs down to 9 nm,13 albeit requiring a substantially higher structural complexity of the waveguide used.
Importantly, the smallest detectable NP diameter in FaNTA is fundamentally limited by the Rayleigh scattering background of water. Consequently, increasing the excitation power to enhance weak scattering signals also raises the background, making the detection of small NPs challenging.
Note that the FaNTA approach generally enables accurate characterization of NPs with dimensions well below the wavelength of light, whereas larger particles are challenging to analyze in the context of NTA due to hydrodynamic hindrance, sedimentation, dominant forward light scattering, reduced localization accuracy, and aberrations. Details are provided in sec. S12 of the SI.
As demonstrated capillary-based NTA provides a streamlined platform for the characterization of nanoscale particles in liquid environments. In the context of the present study, its primary capability lies in the accurate determination of hydrodynamic diameters and size distributions of mono- and polydisperse NP ensembles, which enables a wide range of applications. In nanoscience, it enables real-time monitoring of the growth dynamics of individual NPs with high spatial and temporal resolution. In life sciences, the approach is particularly attractive as a non-destructive method for the characterization of nanoscale biological objects, such as viruses or vesicles.
Here previous FaNTA studies have demonstrated the analysis of SARS-CoV-2 viruses,28 cowpea chlorotic mottle viruses,8 and bacteriophages (T4-phages,29 Lambda-phages11), with high precision and long tracking durations, highlighting the capability of FaNTA for unlabeled viral particles in the size range of a few tens to a few hundred nanometers.
In addition to bioanalytics, further prospective applications include monitoring the NP content in industrial fluids,30,31 detecting and characterizing nanoscale contaminants in water samples32 and pharmaceutical products.
The capillary-based FaNTA approach is in principle transferable to other liquid media, as demonstrated, for example, for the 1-ARE fiber in a nanorheology study.22 Note that reliable application requires careful consideration of the medium viscosity and sufficient signal-to-noise ratio, which depends on adequate refractive index contrast between the particle and the surrounding liquid.33 Overall, the structural simplicity, robustness, and fiber compatibility of the capillary approach make it a promising tool for routine characterization of nano-objects across disciplines.
In contrast to scanning electron microscopy and transmission electron microscopy, FaNTA enables analysis of nano-objects in their native fluidic environment and does not require particle immobilization, which can potentially alter NP properties and interactions.
Even though the presented NTA experiments were conducted under static conditions, the capillary platform is inherently compatible with microfluidic operation schemes. Stopped-flow configurations can be readily realized by sequential introduction of defined particle ensembles into the observation region,34,35 and NP tracking under low, well-controlled flow conditions at different Peclet numbers is feasible by incorporating drift-correction.36 Thus, while the present study focuses on methodological validation in a stationary regime, the capillary platform offers a solid foundation for future integration into flow-based lab-on-a-chip architectures, which is the subject of a future study.
The added value of the capillary-based FaNTA approach in a microfluidic context arises from its intrinsic waveguide-based excitation directly within the liquid-filled channel, its compact fiber-compatible geometry, the extremely small sample volume required, and the fully enclosed configuration. Together, these features enable straightforward integration into micro- and optofluidic architectures while maintaining controlled measurement conditions.
The primary application demonstrated in this work is the reliable determination of hydrodynamic diameters and size distributions of various nanoscale species under different scenarios in aqueous environments. Specifically, we demonstrate the capillary system's ability to resolve monodisperse ensembles and polydisperse nanoparticle mixtures, as well as monitor the formation of temperature-induced clusters of functionalized nanoparticles. Additionally, we defined the upper operational limit for the largest nanoparticle size and experimentally verified the smallest diameter of nanoparticles that can be determined with this system.
Optical simulations and experimental results confirm diffraction-limited imaging performance, supporting reliable particle tracking in a streamlined geometry.
While the present study primarily concentrates on the methodological validation and benchmarking against established fiber platforms in the context of FaNTA, the capillary-based approach may serve as a foundation for future investigations of nanoparticle behavior in confined geometries. Owing to its structural simplicity, robustness, and fiber compatibility, the system is well suited for potential integration into microfluidic environments. In the future, this technology may find applications in fields such as nanoscience, bioanalytics, and environmental monitoring. Overall, the capillary platform provides a streamlined and accessible implementation of FaNTA for nanoscale particle characterization within the experimentally validated parameter range.
Supplementary information (SI) is available. See DOI: https://doi.org/10.1039/d6lc00339g.
| This journal is © The Royal Society of Chemistry 2026 |