Open Access Article
Mike Hardy
*a,
Pooja P. Kanade
a,
Emma Buchan
bc,
Pola Goldberg Oppenheimer
bc,
Cillian P. T. McPolin
de and
Robert M. Bowman
a
aSmart Nano NI, Centre for Quantum Materials and Technologies, School of Mathematics and Physics, Queen's University Belfast, Belfast BT7 1NN, UK. E-mail: mhardy04@qub.ac.uk
bAdvanced Nano-Materials Structures and Applications Laboratories, School of Chemical Engineering, University of Birmingham, Birmingham B15 2TT, UK
cHealthcare Technologies Institute, Institute of Translational Medicine, Mindelsohn Way, Birmingham B15 2TH, UK
dDigital Catapult, 8 Lanyon Place, Belfast, BT1 3LP, UK
eDigital Catapult, 101 Euston Road, London, NW1 2RA, UK
First published on 18th March 2026
The global portable spectroscopy market is rapidly expanding, with optical technologies composing the greatest market share. One prominent light-based technology is Raman spectroscopy, which confers benefits in terms of high selectivity and thus untargeted detection and multiplexing capabilities. Alongside this, plasmon-enhanced Raman technologies can provide ultra-low, even single molecule, detection. In this article, we analyse the current trends in the miniaturisation of Raman systems, including constituent components, evaluating current market needs, and providing a prospective on likely developments within Raman spectroscopy systems in the coming years. In particular, the progress from handheld Raman systems, which have surged in popularity since 2010 in a plethora of application spaces, to fully integrated on-chip Raman devices, is surveyed. Such palm-sized devices offer potentially easy integration into, for example, consumer white goods at home, and lightweight drone systems, and thus could transform the portable sensing landscape.
Increasingly, there is a need for portable sensing solutions as analytical analyses are needed away from university labs, clinics, to factory floors, home and outdoor environments. Such systems need to be easily manufactured, robust, with reasonable power consumption, as well as having easy operation. To this end, spectroscopic devices fit the bill, being potentially compact systems, at least carriable, and providing a wealth of information about a target sample. Optical techniques, in particular, have received increased attention, owing to their quick and easy implementation, and forming a part of the expanding global photonics-based technology market. Optical spectroscopy systems are particularly amenable to miniaturisation. Raman spectroscopy is one especially prominent optical spectroscopic technique making inroads into commercial adoption, which has with it advantages over companion technologies.
Raman scattering is the inelastic interaction of light via molecular vibrations and carries with it well-known advantages in terms of high analytical specificity (selectivity), made possible by inherently sharp peaks, and in the modern era, facile sample preparation. Like infrared (IR) absorption spectroscopy, Raman spectroscopy is typically non-destructive, but with the added advantage of being insensitive to water, which is a very weak Raman scatterer, thus enabling a wide array of applications. Most sensors take indirect measurements1 i.e. on an ion or molecular species other than the target (from which the target analyte can subsequently be identified and/or quantified) but Raman spectroscopy can be performed directly or indirectly meaning with or without an intermediary functionalisation molecule at the sensor surface.2 Pertaining to the spectroscopy aspect of the technique, further advances in lasers, optics, filters, spectrometers and detectors have made Raman, while once expensive and difficult to perform well, now accessible. Moreover, the marriage with plasmonic enhancing media in the context of surface enhanced Raman spectroscopy (SERS) has made trace level detection possible, albeit debate remains over SERS' place as a properly quantitative analytical technique. Nevertheless, Raman and SERS have made tremendous progress in recent decades. However, much of this advancement has been in the laboratory where Raman spectroscopy and its various derivative techniques have been applied in large research spaces.
The market for handheld Raman systems has boomed in recent years (say, 2010s – onwards) driven by applications outside of the laboratory, where spectra can be rapidly converted into actionable information.3 Alongside this, small devices, including microfluidic devices, and small sensing chips as in SERS sensors, have been in development. These advancements not only serve the portability requirement but offer a smaller form factor, and thus also constitute the additional advantages of lower material cost and a smaller bill of materials (BOM).4 It is a good question, however, just how integrated, how miniaturised, Raman systems will go, what is possible with modern technology and what industry needs.
![]() | ||
| Fig. 3 Emerging lithographic techniques. UVL = conventional UV lithography, DUVL = deep ultraviolet lithography, EUVL = extreme ultraviolet lithography, XRL = X-ray lithography, EBL = electron beam lithography, FIBL = focused ion beam lithography, SL = soft lithography, SPL = scanning probe lithography, ENFOL = evanescent near-field optical lithography, IL = immersion lithography, STL = stereolithography, TPL = two-photon lithography, BCL = block copolymer lithography, NSL = nanosphere lithography, NIL = nanoimprint lithography, EL = edge lithography, EHL = electrohydrodynamic lithography, CFL = capillary force lithography, NFEAL = near-field electrospinning-assisted lithography, ML = magnetolithography, MRDL = magnetorheological drawing lithography, NTP = nanotransfer printing. Full details of all techniques in Stokes et al. Adapted/reproduced from ref. 8 with permission from Springer Publishing under Creative Commons CC-BY-4.0, K. Stokes et al. Discover Nano, 18, 153, copyright 2023. | ||
More recently, developments in Raman technology have included better optical filters, improving sensitivity with higher bandpass transmission percentages and sharper cut-offs. The latter has been especially useful in low-frequency (THz) Raman applications, which is useful for garnering structural information from various samples, for instance 2D material analysis.10
Benchtop Raman instruments started to appear in the 90s and into the 2000s as systems, while still lab-based and on the 10 kgs-scale, were now becoming more integrated. Such systems adopted more user-friendly software with graphical user interfaces (GUIs) that ensured Raman systems were accessible to a wide-range of scientists, not only spectroscopy specialists. Moreover, associated software packages for data post-processing, which can perform machine learning tasks and have sizable spectral libraries, are evermore available. Inscore (2011), for example, built up a significant Raman spectral library of 150 illicit drugs.11 This kind of data bank, for instance can be useful for law enforcement, via use of a simple spectral matching algorithm as part of software on a portable Raman sensor at a crime scene. Similar libraries are needed for enhanced Raman analyses, where spectral peaks may shift position slightly, new peaks appear12 or those measured in complex matrices with confounding substances,13 for example, food debris in an analysis of oral fluid without filtration or centrifugation.14
Benchtop systems, while ‘portable’, are intended primarily for laboratory use and remain popular for high-end Raman analyses and routine, high-throughput analytical analyses. True hand-held Raman instruments, of the order of kgs, appeared subsequently, gaining traction from 2010s onwards, and have continued to be popular. One of the interesting developments are the number of accessories now available in benchtop and handheld Raman systems. This includes xyz translation stages with colinear cameras for Raman microscopy and various adapters for different kinds of samples, e.g. cuvettes and SERS media.
![]() | ||
| Fig. 4 Raman probe systems. (a) Ultrafine fibre Raman probe with high spatial resolution and fluorescence noise reduction. (i) A schematic illustration of the probe. (ii) Photographs of the probe. Scale bars indicate 30 μm. (iii) and (iv) Simulated trajectories of light emitted from the collection fibre into air (n = 1) and ethylene carbonate (n = 1.42), respectively. (v) and (vi) Simulated trajectories of light emitted from the excitation fibre into air and ethylene carbonate, respectively. (vii) Experimental setup for Raman spectroscopy using the probe. (viii–xv) Measurements of spatial resolution. (viii) Experimental setup for determination of spatial resolution of the probe. (ix) Microscopic observation to confirm the position of a polypropylene (PP) particle relative to the probe in the YZ plane. (x) Microscopic observation to confirm the position of the PP particle relative to the probe in the XY plane. (xi) Raman spectrum of the PP particle measured with the probe. The spectrum was averaged over two spectra taken with incident power of 20 mW and 60 s. (xii) Area of the peak of PP plotted against the YZ plane. (xiii) Peak area profile plotted against the Z axis made by projection of the profile shown in (xii). (xiv) Peak area profile plotted against the Y axis made by projection of the profile shown in (xii). (xv) Peak area profile plotted against the X axis at (Y, Z) = (15, 20). Adapted/reproduced from ref. 20 with permission from American Chemical Society, Yamanaka et al. J. Phys. Chem. C, 120, 2585–2591, copyright 2016. (b) Intracranial probe design and skull model for Raman spectroscopy in traumatic brain injuries. (i) Clip is used to aid device positioning and probe alignment: (i) cross-sectional analysis of the Raman probe housing and thread. (ii) Cross-sectional analysis of the clip and baffle slots. (iii) Tightening and alignment clip fitted to the probe housing. (iv) Aerial view of the clip. (v–viii) In situ analysis of the bolt: (v) approximation of the frontal bone at Kocher's point. (vi) and (vii) Top and side views of simulation. (viii) Implementation of load and constraints. (ix) Section analysis of the housing (left) to demonstrate the internal ledge and drawing of top view of the probe housing (right), with the dimensions of the ledge indicated. (x) Points of high stress in ABS plastic (acrylonitrile, butadiene, styrene) and fracture propagation at the bolt joint. The legend is indicative of the von Mises stress developed in the structure. (xi–xiv) Development of a skull model. (xi) Fully assembled model. (xii) Sample holder internal to the skull. (xiii) Sample holder at Kocher's point. (xiv) Medical device in situ. Adapted/reproduced from ref. 18 with permission from American Chemical Society under Creative Commons CC-BY-4.0, Mowbray et al. ACS Biomater. Sci. Eng., 7, 1252–1262, copyright 2021. (c) Imaging and transmission of a nested antiresonant fibre (NANF) and fibre-probe. (i) SEM images of an unmodified NANF facet. (ii) Transmission of NANF with and without microlens. (iii) Image of NANF facet, with a super continuum laser coupled in. (iv) SEM image of the fibre–microlens probe. (v) Image of a fibre–microlens probe with super continuum laser coupled in. (vi) A scanning optical microscopy experiment shown schematically. (vii) Reconstruction of the excitation electric field intensity in the xz plane, showing the Gaussian distribution fitted to the xy intensity at each z′ position. (viii) Reconstruction of the excitation field intensity in the yz plane, showing the fitted Gaussian at each z′ position. (iv) Measured peak intensity at the centre of the Gaussian fit (x0, y0) at each z′ position. Adapted/reproduced from ref. 19 with permission from American Chemical Society under Creative Commons CC-BY-4.0, Groom et al. ACS Photonics, 2024, 11, 3167–3177, copyright 2024. | ||
The utility of fibre-probe based Raman instruments is acutely dependent on application. For instance, while a spatially imprecise measurement may suffice for a homogeneous sample measurement, compositionally heterogeneous samples may require high spatial resolution Raman maps.23 One example is in breast cancer. While hand-held probes have been used to identify positive cancer margins, e.g. brain cancer24 and cervical cancers,25 specific cancers may prove less amenable to hand-held probe analysis; for instance, ductal carcinoma in situ (DCSI), which is responsible for high rates of re-excision in breast cancer.26 Here, a microscopy/high-resolution Raman mapping approach is required for accurate pathological identification.23 Elsewhere, some portable instrumentation may require outside use, and the variation in ambient conditions can cause problems like detector saturation or variable background, which are not present (or easily controlled) in lab-based instrument use.27 Although a laser spot size on order of 10 μm is possible, the actual location measured will be limited by ‘handshake’ by the operator, perhaps as much as 2 mm, which may or may not be sufficient depending on the nature of sample inhomogeneity and desire to measure specific regions of compositional interest. At best, human hand tremor is at least at the level on the order of 100 μm, and thus precise robotic, or co-operative robotic, control may still be required. Microscope attachments add undoubted complexity to portable devices and still may not provide needed locational accuracy in some cases.27
Full integration of all sensor components, i.e. light source, detector, sample analysis region, is costly, chiefly due to alignment and in- and out coupling of light.29 Thus, small, yet ‘separated’ or ‘modular’ Raman systems are attractive. Sharma and colleagues have examined a range of miniature heterodyne (i.e. signal frequency mixing) Raman spectrometer systems, which, like Fourier transform Raman analyse spectra in the time domain but without moving parts i.e. mirrors, required in a normal interferometric set-up. The system further bypasses the throughput limitation imposed by the finite-size slit aperture in a conventional dispersive Raman spectrometer.30 The group have explored one-grating31 and two-grating systems (with integrated beamsplitter) of varying size,32 monolithically, or fabricated in multiple parts, most recently as light as 60 g with a footprint as small as 6 cm3 and 8 cm−1 spectral resolution,30 which is competitive for a miniature system. These small Raman systems are designed for external light sources and sensing elements, a simpler arrangement than on-chip solutions.
Despite different sizes and arrangements, most of the components of Raman systems remain the same, with some exceptions, where different parts or interchangeability is needed. This often corresponds to special kinds of experiments. For example, multiwavelength SERS studies – surface enhanced Raman excitation spectroscopy (SERES) – will need a mechanism to exchange the laser line (bandpass) optical filters and Rayleigh (longpass) filters depending on the laser wavelength used. Consequently, SERES typically remains a research tool confined to large benchtop Raman systems. Generally speaking, the optimal laser wavelength(s) needed is dependent on applications and the exact type of Raman experiment – corresponding to resonance wavelengths for the target molecules, fluorescence rejection, or wavelength for plasmon resonance in SERS.21 In another kind of Raman experiment, notch filters can be used in place of normal Rayleigh cut-off optical filters where anti-Stokes Raman bands (i.e. energy transfer from molecule to Raman photons) are required, which are typically much weaker but useful for sample temperature determination when compared to the Stokes Raman band intensities. THz (low-frequency Raman) requires especially narrow cut-offs (e.g., within tens cm−1) to capture the array of Raman bands associated with structural information in this range. For instance, the authors in ref. 31 use two different Rayleigh filters because of overlapping wavelengths above and below the grating blaze wavelength i.e. same spatial frequency (Fizeau fringes) in their diffraction grating-based interferometric Raman system. Elsewhere, systems for measuring Raman at a depth, spatially offset Raman spectroscopy (SORS), require an offset detection element to monitor backscattered photons from within a sample.33–35
Even with technological advances, many trade-offs in performance exist as devices shrink; for example, one notable limitation of miniaturised Raman systems is laser stabilisation. Small form factor Raman systems typically use diode lasers, which are cheaper than HeNe or solid state lasers, but with a trade off in performance in terms of wavelength (spectral) and power output stability. Ilchenko (2024) proposed a cm-scale miniaturised Raman spectrometer composed of non-stabilised laser diodes, densely packed optics, and non-cooled small sensors.36 The authors achieved excellent sensitivity comparable to bulky research-grade Raman systems, and an overall 7 cm−1 resolution within the fingerprint region by using an in-built calibration material. Recently, we have provided a summary of the spectral resolutions in commonly available benchtop and handheld Raman systems, which spanned from 1 cm−1 to 11 cm−1. A spatially offset Raman device with 830 nm excitation laser had a spectral resolution of 14 cm−1 (see SI section ref. 21). These values are dependent on the laser wavelength and exact part of the spectrum analysed (different Raman peaks are at different Raman-scattered wavelengths). Often, a vendor will provide a range of values. Further integration/miniaturisation of Raman devices will push these values 10 cm−1+ and have a greater reliance on algorithmic means in interpreting spectra. The usefulness of this will then depend on application, and this may mean that on-chip Raman devices, if they are available routinely as a commercial product, may be very application-specific.
Predictably, downscaling spectrometers comes at a performance trade-off cost in terms of measurement speed, spectral bandwidth, resolution, and dynamic range, and hence must be tailored to the specific application. Cooling strategies must normally be found where thermal management may be difficult on the compact scale. Integration with prevalent CMOS silicon fabrication and use of heterogeneous integration for on-chip lasers and detectors is one strategy to keep costs down.42 Specifically, maintaining etendue (collected light solid angle × sample collection area) conservation of the optical set-up is to be considered. Here, then, the bottleneck is the least effective component.17
In an assessment of the current state-of-play of portable spectroscopy, Crocombe defines four different categories of mini-spectrometer use:43
1. Stand-alone spectrometers for laboratory use,
2. Integrated spectrometers in portable spectroscopic devices,
3. Small spectrometers in consumer goods, and
4. Spectrometers marketed directly to consumers.
Category 4 is an especially interesting suggestion, but one which may find regulatory pushback. A 2021 report suggests market penetration for consumer applications as minor40 but this is expected to steadily increase.41 Crocombe highlights white goods and consumer health and care products but interest in on-chip Raman could mean applications could conceivably go much further.43 Recently Li et al. (2022) has provided a useful review on the current standing of miniaturised spectrometers.42 Such systems will still require small parts, and to achieve increasingly compact components in Raman systems entails a focus on reliable manufacture, spurred by recent developments in lithography.8
![]() | ||
| Fig. 5 Types of MEMS devices and technologies used in miniaturisation of Raman and other systems. (a) (i) Scanning electron microscopy (SEM) images of a two-dimensional MEMS scanning mirror, (ii) inner axis torsional spring, (iii) outer axis comb bank. Scale bars are 250 μm. Adapted/reproduced from ref. 61 with permission from Optica Publishing Group, Piyawattanametha et al. Opt. Lett., 2006, 31, 2018–2020, copyright 2006. (b) (i–iv) SEM images of polycrystalline diamond hotplates. Adapted/reproduced from ref. 71 with permission from John Wiley & Sons under Creative Commons CC-BY-3.0. Thomas et al. Small, 2023, 19, 2303976, copyright 2023. (c) (i) Schematic of a chip-scale MEMS-tuneable vertical cavity surface emitting laser (VCSEL), (ii) and (iii) show the photo and SEM image of a MEMS-tuneable VCSEL. Adapted/reproduced from ref. 47 with permission from Optica Publishing Group Atabaki et al., Opt. Express, 2021, 29, 24723–24734, copyright 2021. (d) MEMS-based miniaturised tensile tester, (i) optical image of the tensile tester, (ii) and (iii) show the SEM images of the contact pads and the polymer nanowire, (iv) schematic of printing a nanowire on top of a MEMS sensor. Adapted/reproduced from ref. 66 with permission from Royal Society of Chemistry under Creative Commons CC-BY-3.0, Ladner et al., RSC Adv., 2019. 9, 28808–28813, copyright 2019. (e) Schematic of a MEMS-based tuneable grating with integrated actuation. Adapted/reproduced from ref. 57 with permission from Optica Publishing Group, Stürmer et al., 2016, Opt. Exp., 24, 23765–23776, copyright 2016. | ||
Hayden et al. used MEMS-based VCSELs for wavelength modulation spectroscopy to demonstrate a CO2 detection limit 2.5× lower than previous measurements.46 Pei et al. demonstrated a near-single-mode fibre Raman laser system with a power of 7.11 W at 1560 nm band.48 Additionally, MEMS-based laser diodes have been used for high-power and low-divergence beams that are required for deep tissue penetration in biomedical applications.49
Micro-heaters are also used to prevent condensation and stabilise the sample environment during Raman measurements, improving the reliability of portable Raman devices. Advanced MEMS micro-heaters made from boron-doped polycrystalline diamond can reach temperatures of up to 2731 K with minimal power consumption, making them suitable for various industrial and environmental monitoring applications.71 These micro-heating systems enhance the accuracy and reproducibility of Raman measurements. Aside from the above applications, we note the possible use of MEMS-based microheaters in the form of (thermal) sequentially shifted excitation (SSE) Raman spectroscopy72,73 to induce slight temperature changes in the sample, which can permit the effective removal of fluorescent background, analogous to SERDS, that does not spectrally shift as temperature changes, as the Raman peaks do.
Hybrid integration of III–V MEMS lasers is another emerging area i.e. using compound semiconductor materials from group III, IV, and V materials like GaAs, InP, InGaAsP, AlGaAs with direct bandgaps and thus high light emissions. This hydrised integration with silicon PICs has produced mode-hop-free tunable lasers with narrow linewidths (<6 kHz) and wide tuning ranges (>20 nm), ideal for Raman and atomic spectroscopy applications.75 Similarly, waveguide-enhanced Raman spectroscopy (WERS) on nanophotonic chips can leverage MEMS-integrated sources to excite analytes directly within low-loss waveguides, improving sensitivity while maintaining a small footprint76 – a kind of on-chip Raman. These developments pave the way for next-generation fully chip-scale mini-Raman systems, combining MEMS tunable lasers, integrated optics, and detectors.
![]() | ||
| Fig. 6 On-chip/waveguide Raman. (a) ‘High index contrast photonic platforms for on-chip Raman spectroscopy.’ (i) The schematic of a patterned high index contrast waveguide. nc and na are the refractive index of core and analyte (top cladding) respectively. (ii) The length factor (LF) comparison for a forward (blue) and a backward (red) propagating Raman signal assuming a fixed waveguide loss of = 5 dB cm−1. (iii) The LF increases for decreasing loss (see eqn (1) in ref. 80, Raza et al.). The dotted lines show the value of the LF at their saturation length (1/waveguide loss) for the four different types of waveguides. (iv) Background scattering from four different waveguide platforms normalized by length factor and coupling efficiency. (v) The Raman spectra of ethanol at the upper cladding are obtained. The dotted lines represent the 880-, 1054-, 1098-, 1275-, and 1456 cm−1 Raman modes of ethanol. Adapted/reproduced from ref. 80 with permission from Optica Publishing Group under OSA Open Access Publishing Agreement, Raza et al., Opt. Exp., 2019, 27, 23067–23079, copyright 2019. (b) ‘A packaged, fibre-coupled waveguide-enhanced Raman spectroscopic sensor’. (i) Rendering of the chip enclosure with optical fibres affixed to the chip and a flowcell that lowers onto the surface of the chip. The top case and flow channels are machined from polytetrafluoroethylene (PTFE), a rubber Kalrez O-ring separates the chip from the top case, and the bottom fixture is machined from aluminium. (ii) Photograph of the fibre-coupled, packaged Raman sensing chip with fibres glued to the edge of the chip after being mounted in separate glass V-groove chips (for mounting purposes). (iii) The packaged chip with the top PTFE cell secured above the chip. (iv) Zoomed-in top view of the area boxed in white on (ii). The position of the O-ring is shown by the dashed white circle (the side clamps are removed prior to O-ring positioning). (v) Top-view schematics of the fibre-bonding region [boxed in white on (iv)]. Components are not to scale. The glass V-groove block is bonded to the chip with epoxy at the tip of the fibre in the etched groove, and with larger volumes of cured epoxy on the sides of the block for improved robustness. Adapted/reproduced from ref. 82 with permission from Optica Publishing Group, Kita et al., Opt. Exp., 2020, 28, 14963, copyright 2020. | ||
The waveguide channel serves two purposes – 1. as an effective medium to facilitate interaction with proximal analyte molecules (surrounding the core) and 2. an easy way to collect the Raman signal (with appropriate filtering of the Rayleigh signal).78,94 One of the problems with on-chip Raman is that waveguides are typically single-mode, meaning that they only efficiently propagate a certain profile of light travelling in the confined space. This is because waveguides are designed to be compatible with wavelength-specific components. On the other hand, Raman emission is inherently multi-mode light, originating from a diffuse source of analyte molecules and thus coupling efficiency is low, compounding already an inherently low signal (cross-section) from the Raman scattering phenomenon. The waveguide can be considered the functional component of an on-chip system where the Raman interaction occurs; however, the wider chip can also be largely photonic-based, aligning with efforts to develop fully light-based miniature systems to replace electronic infrastructure.
000 times per second, were used as electronic switches, later replaced by small semiconductor devices, transistors. At the time, this was revolutionary, vacuum tubes had short lifetimes and the light could attract moths, meaning one's computer might need ‘debugging’. Transistors, however, did not solve all problems because small devices required many interconnects, which was not feasible until the advent of the microchip.96
Developments in complementary metal oxide semiconductor (CMOS) technology in the early 90s meant that photodetectors, readout circuits, and data processing units could be placed on the same chip. The CMOS active pixel sensor architecture significantly increased readout speed, reduced size and lowered power needs.97 Fabrication improvements in the 2000s resulted in more complex analogue circuits e.g. analogue to digital converters, and rudimentary digital circuits on the same chip.9 More recently, light-based circuit technology has garnered interest – photonic integrated circuits (PICs) – which can replace electrons with light and can lower costs and size in optical sensing devices, having been proposed for medical wearable technology, which for example can monitor blood sugar or alcohol levels.98 Such examples are truly system-on-chip (SoC) designs that incorporate data acquisition, processing and communication into a single chip.9 While typically much larger than electronics, μms vs. nms say, PICs are starting to garner interest as an alternative technology. The real driver for the adoption of PICs is a reduction in losses, while being much more lossy than optical fibres, have significantly lower losses than electrical circuits.
PICs are also a promising vehicle for miniaturised sensing, allowing the use of photons as part of the device to investigate molecules of interest. While unlikely to fully replace silicon electronics, PICs open up new possibilities including easy multiplexed analyses of complex matrices.29 Many sensing PIC systems are currently surface plasmon resonance-based, for example in a micro-ring resonator or Mach–Zehnder interferometry arrangement, but on-chip Raman systems have appeared for creatine detection in the context of kidney disease and sarin (nerve) gas.29 PIC material choice is important. Si photonics refers to processes used to make PICs using existing CMOS processes. Silicon, however, is only transparent above 1.1 μm but silicon nitride can be used (Si3N4) for transparency in the visible range, needed by Raman and fluorescence.94 Silicon nitride thus offers a less lossy option than silicon and is ideal for the visible and near infrared range, having a wider bandgap. Further, the high refractive index contrast of silicon nitride aids electric field concentration.94 Indium phosphide (InP) offers an alternative for active components – light sources and detectors. Hybrid integration (different chips packaged together via lateral edge coupling or vertical flip chip) and heterogeneous integration (different materials) are now achievable and scalable.
Wuytens et al. developed intracellular Raman probes using gold nanoparticles for enhancement of Si3N4 with a chip size on the μm-scale.109 The same researchers have also patterned nanostructures within waveguides for increased Raman signal via similar plasmonic enhancement. The authors have fabricated bowties nanostructures, which have received extensive research interest in SERS and wider plasmonics research as a high sensitivity nanoplatform with a geometry amenable to resonance wavelength tuning for optimum concentration of impinging light at a wavelength of choice.110
Dochow et al. developed hexagonally arranged, multicore (n = 61) single-mode optical fibres (NA = 0.1; d = 5.5 μm) with UV-patterned fibre Bragg gratings close to the Raman Stokes light pick-up point to suppress background from the optical fibres in an on-chip Raman device.90 Use of filters can also be reduced by using high wavenumbers where silica has no interfering Raman response. Similarly, autofluorescence from silicon dioxide cladding can be a problem.17,94 In the context of reducing the impact of background signal, Le Thomas et al. have discussed different strategies. Clear approaches exist involving analyte enrichment with an absorbing/adsorbing layer to concentrate target molecules, or employing resonant Raman scattering where the laser wavelength corresponds to a molecular resonance and thus returns a larger Raman signal, perhaps up to 103×. This, then, entails also using a waveguide medium suitable at this resonant wavelength – the authors have recently studied aluminium oxide and 360 nm excitation.
Away from material considerations, advanced data analysis strategies can also mitigate the effect of background signals in on-chip devices. For example, in a study into cancerous cell identification, Dochow et al. employ a statistics-sensitive non-linear iterative peak-clipping (SNIP) algorithm for background identification and the commonly used, dimension-reducing, principal component analysis (PCA) process, but for noise removal, in combination with optical trapping within a microfluidic Raman device.114 Further, the authors use normalisation to a prominent high-wavenumber C–H stretch Raman peak, alongside spectral truncation. We note that the exact algorithms used and indeed the precise order in which these various processes are performed could be critical, as discussed in a Raman review on saliva as a diagnostic biofluid.14 An optimistic view on dealing with background, pertaining mostly to fluorescence from Raman dye molecules, say, should be positive as algorithms for background subtraction have improved in recent years. However, spectral processing from portable devices, and the resultant spectra, will still need frequent checking by human actors, arguably like a lot of other uses of advanced data analysis applications. Another option to limit the effect of background influence is to increase signal via the incorporation of plasmonic enhancing media – surface enhanced Raman spectroscopy.
SERS substrates are generally viewed as consumable. This has proved problematic for precisely engineered SERS architectures, say via electron beam lithography, which then have a prohibitively high cost per measurement. Reusability in SERS substrates have been explored but with little traction. Thus, low-cost, less reproducible nanoparticles, which retain a high enhancement and whose properties are well-understood, have remained popular. Research into ordered SERS substrates is ongoing, attracting each year, hundreds of publications, offering better spot-to-spot uniformity of signal and batch-to-batch reproducibility than nanoparticle counterparts.
At the time of writing the authors' opinion is that future SERS chips will probably continue to form as accessories to Raman systems, rather than in-built components. This is for a number of reasons:
1. This allows the spectroscopist the option to perform ‘normal’ Raman spectroscopy, which may be adequate in the high concentration regime, without having to consider the effects of adsorbing to a plasmonic surface.
2. Unnecessary device complexity and economy of materials – simpler Raman devices (hand-held or chip-scale), and without the need for additional cost of gold/silver nano-structures – although we note that while top-down fabricated SERS substrates e.g. electron beam lithography, have proved prohibitively expensive, the cost of metal nanoparticles/colloids is very cheap. The cost per measurement will be critical to SERS full adoption by the analytical community, which, needs to be cents rather than dollars or even $10s (as is often the case).
3. No concerns of device shelf-life – incorporation of plasmonic nanostructures for SERS brings with it concerns over device shelf-life, especially true for silver-based nanostructures, which oxidise rapidly. Having the SERS chip externally packed, which can be opened and then measured by a hand-held Raman system, or alternatively, say, nanoparticles dropcasted or flowed through an on-chip Raman microfluidic system, bypasses such concerns.
4. Reusability for on-chip devices – SERS is normally considered a single measurement technique. Even where molecules can be removed from a surface, or a microfluidic channel exists, some residue, analyte molecules or nanoparticle fouling often remains. The upshot being a less cost-effective device.
In addition to the points noted above, is the contention that SERS cannot be a fully analytical technique. For instance, a histogram of SERS enhancements across a SERS-active area often shows skewed ‘long tail’ statistics, i.e. high kurtosis, meaning a small number of surface sites on the SERS-active area contribute disproportionately to the observed SERS signal.118 This is problematic then from a reproducibility and quantification perspective – the number of these ‘hot hotspots’ can vary from batch to batch. Thus, many see SERS as still in need of development in order to make an application impact,117,119 and having not met its potential as an analytical technique. We understand these concerns, and are sympathetic to them, realising that the electromagnetic hotspots that can be formed via plasmon interactions in the nano-geometries mediating SERS can be difficult to control. However, we would argue that SERS might be like any other analytical technique in that it can avail from calibration e.g. by an internal standard. Elsewhere, focus has been given to better fabrication strategies as noted by Dawson in ref. 120:
‘…the key issue is more the precise control of the enhancement component, that we do understand well, namely the electromagnetic enhancement. That, in turn, requires very precise control of substrate fabrication that is highly repeatable and very affordable, a combination that has proved remarkably elusive over the years’.120
The above Faraday Discussion extract from ref. 120 also alludes to the debate over the exact enhancement mechanism in SERS i.e. how much of it is from ‘chemical effects’ – essentially alterations to molecular species being analysed as they adsorb to metallic surfaces. This is opposed to electromagnetic routes of enhancement, which are plasmon-mediated. While electromagnetic enhancement is undoubtedly by now understood as the predominant enhancement mechanism,115 chemical effects do exist. And while much more modest in comparison, the misunderstanding, or uncertainty, surrounding chemical effects can be off-putting towards the use of SERS in analytical space. To this end, we echo some of the commentary in ref. 120 that suggests ‘tying down’ the contribution for any chemical contributions to the enhancement for specific molecules. This may mean that SERS applications must be considered carefully with the specific analyte molecules to be detected in mind.
An emerging area in diagnostics are organ-on-chip (OoC) models, which seek to emulate various bodily organs on the nanoscale. OoCs conveniently offer an alternative to otherwise misrepresentative animal environments, and consequently failed drug developments, which do not always emulate human physiology. Moreover, OoC use sidesteps any ethical considerations. Similarly, in vitro analyses via cell cultures are often inadequate, where pathophysiological responses cannot be faithfully repeated due to, for instance, inaccurate inter-cell interaction or external interferences. Initially, starting as a lung-on-chip model, analogues to the blood–brain barrier, heart, gut, and many others have since appeared. However, integration with high-end, bulky Raman systems is challenging, and hence, SERS media incorporated into such systems offer viable solutions to increase sensitivity in OoC models.83,125 Further, the microfluidic nature of such systems could resolve the repeatability problems with many SERS analyses,83 averaging the SERS signal.
An emerging area in SERS sensing are wearable SERS media, where human-worn patches can be used to monitor biofluids.126,127 For instance, Yang Li et al. designed and characterised a wearable SERS patch with microfluidic channel and wicking paper for sweat analyses in athletes.128 The sensor incorporated a carbon tape layer to block incident laser light from skin interaction and reached a maximum temperature of 44.5 °C (from 37 °C) temperature increase, tolerable for in situ analysis. Further, the device suffered no delamination with significant strain and remained comfortable for human volunteers during use, with puncture testing showing a strength of 20 N for a 100 μm film, about twice as strong as those commonly used in food packaging. Koh et al. developed a portable technology comprising an outer sweat-absorbing layer, a SERS active layer containing a plasmonic silver nanowire, and a dermal protecting layer.129 The feasibility of the technology was demonstrated using 2-flurormethamphetamine (2-FMA) for drug detection. Similarly, Chung et al. fabricated a wearable flexible sweat pH-based sensor using a combination of electrospinning of thermoplastic polyurethane and gold nanofibers.130 The developed device required only 1 μL of sweat for measurements and indicated good repeatability. Mogera et al. also developed a label-free paper patch for continuous sweat rate and metabolite detection, including uric acid.131 Such technologies pave the way for various adaptations in wearable SERS for illegal drug surveillance and non-invasive drugs monitoring in patients, as well as the measurement of a wide range of health biomarkers beyond those found in sweat.
SERS has also found application in miniaturised immunoassays at the point-of-care in the detection of a range of diseases, such as those relating to the respiratory system. Liu et al. conducted a study to identify the presence of COVID-19 using a lateral flow immunoassay comprising functionalised two-layer silver-coated SiO2 nanoparticles as SERS nanotags.132 When coupled with SARS-COV-2 virus protein, diagnosis of IgM and IgG antibodies was achieved. Leong et al. has also detected COVID-19 using SERS but in the context for a miniaturised hand-held breathalyser for the mass screening of COVID-19.133 While work on integrating SERS into commercial products, or as an option for analysis as an accessory, many of these systems form a wider trend of using Raman spectroscopy in healthcare settings, at the point-of-care, where the technique is now showing tremendous promise in portable diagnostics space.
![]() | ||
| Fig. 7 Point-of-care Raman systems. (a) Point-of-care micro-engineered device for traumatic brain injury (TBI) bio-diagnostics. (i) Neuro-medical imaging with magnetic resonance imaging (MRI), (ii) schematic of optofluidic chip indicating how one drop of blood moves through the device with three panels (right) of optical images of the chip, (iii) schematic of multiplexed system indicating analyses of biomarkers, (iv) acquired SERS spectrum compared with the pre-established biomarker fingerprints and (v) indicates how the biomarker level can be monitored over time using the developed optofluidic technology. Adapted/reproduced from ref. 148 with permission from Springer Nature, Rickard et al., Nat. Biomed Eng., 2020, 4, 610–623, copyright 2020. (b) Smartphone Raman spectrometer and data processing for analysis of, for example, drug classification. (i) Smartphone spectrometer with identified band pass filter arrays attached to a rear camera with an attachable Raman system equipped with 785 nm laser. (ii) Images captured at chosen wavelengths encoded as a spectral barcode. Adapted/reproduced from ref. 144 with permission from Springer Nature under Creative Commons CC-BY-4.0, U. J. Kim et al., Nat. Commun., 2023, 14, 5262, copyright 2023. (c) EyeD technology for rapid traumatic brain injury point-of-care diagnostics indicating concept (i) through to (ii) design of EyeD with 3D printed model, and (iii) lab prototype. (iv) shows the eye anatomy and (v) an acquired spectrum from a self-organising map (SOM) analysis, providing a ‘window into the mind’ (vi). And (vii and viii) engineered EyeD designs and (ix) visualisation of SOM map data separation into nodes of similar spectra. Adapted/reproduced from ref. 164 with permission from American Association for the Advancement of Science under Creative Commons CC-BY-4.0, Banbury et al., Sci. Adv., 2023, 9, eadg5431, copyright 2023. | ||
The primary aim of PoC Raman devices is to overcome the cost and mobility limitations of traditional benchtop spectrometers and produce portable, easy to use, and affordable devices which maintain performance. Recent advancements in optics, electronics, and miniaturisation technologies have ensured the capabilities of Raman have found applications outside the traditional laboratory, thus enabling rapid and on-site analysis across diverse applications.136–138 These typically compact and lightweight devices are equipped with user-friendly interfaces, making them accessible to specialist and non-specialist users alike. PoC devices, unlike traditional systems often integrate advanced features such as wireless connectivity, battery-powered operation and robust data analysis software, frequently utilising cloud-based services, that allow for real-time diagnostics and decision making in the field.139–141
With the transition from bulky laboratory instrumentation to highly compact systems, modern PoC Raman devices have advanced to include handheld Raman spectrometers such as Thermo Fisher TruScan™ RM, Agilent Vaya™, and B&W Tek TacticID™. Widely used in real-world applications including, hazardous and illicit compound identification, these ergonomically designed devices provide highly efficient tools for investigators. TacticID™, for example, has the ability to measure through packaging to avoid direct contact with the sample thus offering the flexibility to operate anywhere without compromising safety.141 Similarly, TruScan™ has been employed in pharmaceutical supply chains to rapidly identify counterfeit drugs.140 With colour-coded easy-to-read results, such technologies can now be used by non-technical operators to rapidly identify chemical compounds therefore eliminating the need for compendial ID testing, which requires specialised laboratory training and significant time.
Furthermore, smartphone-based Raman devices, leveraging the advanced camera technology in modern smartphones, can be used for PoC applications. For example, Rentzepis et al. have developed a smartphone-based Raman spectrometer system to analyse drugs and biological molecules.142 The setup incorporated a diode laser and a diffraction grating to record the Raman spectrum. With the smartphone placed behind and facing the transmission grating, the laser then illuminates the sample of interest with the camera subsequently recording the spectrum. Lebanov et al. applied a similar approach combining smartphone-based technology with machine learning for essential oil quality evaluation143 and Kim et al. identified unknown drugs with 99% accuracy using their smartphone Raman spectrometer to define a spectral barcode of each compound.144 While smartphone cameras have proved useful, their performance is typically unsuitable for routine Raman analysis, which is a weak effect (few photons). In addition, a poor dynamic range, high noise, and possible differences in performances between handset batches could be problematic – issues representative of detectors optimised for photography rather than scientific measurement. Should some of these criteria be relaxed, however, e.g. a qualitative identification or semi-quantitative measurement specified rather than quantitative one, smartphone-based systems could be useful as an element for widely accessible Raman analysis.
PoC Raman devices present multiple advantages over traditional Raman instrumentation. Firstly, in their portability, with devices like TruScan™ and Agilent Vaya™ weighing 0.9 kg and 1.62 kg respectively, and combined with their user-friendly designs, are well suited for both bedside and field use.140,145 Perhaps the single most advantageous use of PoC Raman devices is in their ability to operate in regions without the need for extensive laboratory infrastructure, enabling access to diagnostics in remote geographical and underserved or low-resource locations. The non-invasive and label-free ability of Raman spectroscopy lends itself well to PoC devices, reducing the overall costs and sample preparation time. For example, Raman systems have been used to directly analyse saliva or blood plasma, bypassing complex biochemical assays. Fujihara et al. successfully discriminated human and non-human blood using a PoC Raman device directly measuring blood spots up to three months old, which is of particular use at a crime scene where unknown blood stains are identified, and subsequent analysis must be performed on location.146 Moreover, with rapid data acquisition (often under 10 seconds) PoC Raman devices allow medical professionals to make on-the-spot decisions in critical care settings, such as identifying N-acetylaspartate, a traumatic brain injury (TBI) biomarker or cardiac troponin I to evaluate cardiovascular health.147,148 Raman spectroscopy provides molecular-level identification of analytes, of particular advantage in biomarker detection or discriminating illicit drugs.
Elsewhere, miniature Raman devices have also been developed for the detection of different skin diseases, including cancers and atopic dermatitis. Lightnovo ApS fabricated a mini-Raman™ device capable of providing molecular composition of the skin up to several hundred micrometres in depth. With dimensions similar to those of car keys and limit of detection (LoD) values of 0.1 g L−1 for p-coumaric acid, the technology is well-suited to clinical practice and for monitoring of disease.149 Similarly, Horiba Ltd. have designed and fabricated two mini-Raman spectrometers; the CC-Raman-NIR spectrometer and the Mini-CCT+ for various applications within life science, forensic and security, and pharmaceutical and cosmetics.150
Perhaps one of the most significant advancements in PoC Raman technology is the incorporation of SERS, which uses metal nanostructures to enhance signal sensitivity151 (also see section 6). SERS has expanded the applicability of PoC Raman devices by enabling the detection of trace-level analytes, such as biomarkers, contaminants, and drugs, in complex matrices such as blood, saliva and urine.136,137,146,152–156 Portable microfluidic Raman systems are often integrated with SERS chips, designed for single-cell analysis and real-time diagnostics. Rickard et al. developed a portable optofluidic chip using SERS to detect N-acetylaspartate in patients with traumatic brain injuries (TBIs).148 The authors use electrohydrodynamic lithography, a technique exploiting instabilities in polymers caused by an applied electric field gradient, to fabricate sub-micrometre gold-covered pillars in an optofluidic chip to identify picomolar concentrations of TBI biomarkers. Elsewhere, Wang et al. developed a portable and ultrasensitive, recyclable SERS-microfluidic biosensor for the detection of uranyl (UO22+) ions, achieving detection limits as low as 7.2 × 10−13 M.157
Despite the clear advantages and benefits of PoC Raman devices, they are associated with several limitations and challenges preventing their widespread use, particularly in the healthcare setting. Firstly, Raman scattering is inherently weak, making it challenging to detect low-abundance analytes. In biological samples background fluorescence can further obscure Raman signals, for example in blood-based diagnostics autofluorescence often overwhelms the signal thus extensive signal processing or SERS substrates are necessary to enhance detection. This brings about a further limitation in terms of overall cost. SERS substrates, requiring nanoscale materials can be costly to produce and are often single use, therefore significantly driving costs for routine clinical testing. Moreover, the listed capabilities of Raman including the non-invasiveness, label-free, and non-destructive nature of the technique, come at the cost of extensive requirements for the instrumentation, i.e. the laser must have a stable wavelength and optical power, there should be low noise associated with the spectroscopic sensor and, the optics within the spectrometer should have a large clear aperture. Rentzepis et al. have applied right-angle geometry in their device to try and circumvent the noise and interference from Rayleigh scattered light – photons without an energy/wavelength change.158
The future of PoC Raman devices lies in their continued miniaturisation, cost reduction, and integration with digital healthcare platforms. Developing robust, low-cost SERS substrates and eliminating the need for sample preparation will be pivotal for widespread adoption.159,160 Moreover, regulatory approval for clinical applications remains a slow and expensive process with devices subject to stringent criteria for sensitivity, specificity, accuracy and reproducibility with many technically ready PoC devices failing to reach markets due to unresolved regulatory hurdles and therefore, such frameworks need to continue to evolve to support the commercialisation of PoC devices. While challenges remain, ongoing innovations in nanotechnology, advances in data analysis strategies161–164 including artificial intelligence,165,166 and system engineering (see section 8) promise to address limitations.
The promise of SERS and microfluidics has recently been surveyed in a Lab on a Chip review article,83 where the authors point out distinct advantages in terms of low reagent volumes, faster diffusion rates, and easier manipulation of reagent with pressure, electrical and magnetic effects amongst others.89 Microfluidic devices have generally required properties, such as sealed interconnects and suitable thermal properties as well as the chemical stability of materials.169,170 Whereas microfluidic platforms have traditionally been made using glass and conventional lithography, other options are emerging, namely stereolithography 3D printing, which uses UV or green wavelength light to harden polymer resists from specified computer aided design (CAD) models, to make fluid channels with diameters on the tens μm to mm-scale.171 We note that 3D printing brings with it its own problems, such as rough channel wall textures and lack of reproducibility. The material must be optically transparent at the laser wavelength(s) required and have low fluorescence background – key in the low volume and low analyte concentration regime. Comment on emerging polymer material choice, for examples PMMA or PDMS, is given in ref. 83 with notes on flexibility and electroosmotic flow where an applied electric field attracts ions, which then also move the solvent molecules. SERS and microfluidics continues to be a hot area within bio-studies with different research groups recently reporting E. coli detection via aptamer-mediated silver nanoparticle synthesis in situ (i.e. AgNO3 reduced by a suitable reagent within the microfluidic channel)172 and secondly, via a piezoelectric transducer generated acousto-fluidic set-up.173 In the latter case, the authors note the possibility of bacterial multiplexing via multiple SERS tags for different bacterial species.
One clear advantage in a SERS context is the averaging of signals through the solution flow, mitigating the large variations associated with SERS measurements, and making SERS a more attractive analytical option,174 offering proper quantification of a target molecule. Going forward, key challenges remain on re-usability of microfluidic SERS platforms and combination with other analytical techniques.83
Similarly, the nature of microfluidic flow means that higher power densities can be used without concern over causing sample damage where heat energy is quickly dissipated and analyte molecules rapidly replenished in the focal region. For this reason, (high-power) near-infrared laser use i.e. 785 nm (typically) with a small focal volume i.e. >40× magnification, say, can be used without reservation.167 Nevertheless, a prominent issue with microfluidic channels remains in the adherence of analyte to channel walls, which can then contribute to the observed Raman signal, undermining quantitative determination. This is a common problem appearing in low concentration SERS studies in general, and warrants, for example, careful consideration of how low-concentration solutions are made in sequential solutions (dilutions) in an analytical investigation (analyte molecules sticking to the glass vial walls). In a microfluidics context, this problem can be avoided with two-fluid flow where an oil layer is incorporated.175,176 Alternatively, disposable, ‘few-use’ microfluidic chips can reduce concern over chip reuse and memory/fouling effects.167 Such systems, then, will have laser excitation and Raman detection off-chip, which is an easier arrangement but may be less convenient than a fully integrated Raman chip.
Portable medical devices represent a hot area, and optical-based systems can form a key part of remote, out-of-the-clinic diagnostics. However, what about the role of Raman miniaturisation, specifically? Regulatory barriers will form an expected pushback, as is the case for any medical implementations, but the signs are positive. A recent report, for instance, details the use of multi-wavelength Raman as useful for Alzheimer's diagnosis at >93% accuracy. The UK-based group now intend on making a suitable portable Raman device.179 Measurements directly on patients might pose more of regulatory problem; analysing external fluids are more straightforward from a regulation standpoint, although problems can still arise in biofluidic storage, pretreatment, and with inherent variations in composition within classes i.e. intra-class variance.14 Should such issues be resolved, Raman spectroscopy could target an array of health conditions.155 While the AI revolution will undoubtedly accelerate progress in many fields of science, it might do particularly well in clinical spectroscopy, where especially information-rich datasets are often generated but that can be difficult to decipher given their complexity. We note the particular complexity of bio-samples, which can contain an array of molecular species alongside the biomarkers of interest. The inherently sharp Raman peaks permit optimal multiplexed detection and arguably thus can couple well with AI and machine learning techniques that can pick out, perhaps hitherto unappreciated, spectral features with diagnostic significance. Aside from advanced data analysis strategies, there is a push for not just portables but wearable devices perhaps additively manufactured, and this could drive Raman instruments in a PoC context right down in size, including wearable SERS chips,127,180,181 perhaps. However, to do so successfully in a competitive application space, such as PoC device development, Raman systems should be considered holistically from the outset – systems engineering – to avoid roadblocks to clinical adoption downstream.
Systems engineering can be defined as a transdisciplinary and integrative approach to enable the successful realisation, use, and retirement of engineered systems.182 This relates to combining multiple interacting elements in an organised manner to achieve one or more purposes. In the case of Raman spectroscopy, it covers combining optical, electrical, mechanical, and software subsystems into an optimal device. The relationship between the subsystems should be considered from the outset, and interfaces identified and documented. While Raman laser wavelength used and detector are normally the first to be considered in the optical aspects of miniature Raman devices, the chosen components can have an acute effect on other system aspects. For instance, a longer (redder) wavelength e.g. near-IR, 785 nm, laser will require a detector with a larger spectral range, as the Raman peaks will be more greatly shifted from the Rayleigh laser line (and more spectrally separated). This can also affect device size (dispersion element to detector distance must be considered). Adjusting the optics can be useful here, but subsequently in turn affects light throughput i.e. signal intensity, and resolution – a higher numerical aperture lens will mean more obliquely incident photons collected. And so forth, the system thus must be considered holistically, and optimised with interdependencies in mind.
Moreover, a life cycle model may be employed to illustrate the sequence of different stages of the process – from initial conception to retirement, such as the ‘V-model’. In this context, the initial optical systems engineering process includes: requirement analysis, feasibility studies (realistic technical/cost possibility), system architecture development, trade studies (comparing the pros and cons, trade-offs for different device designs), definition of subsystems and interfaces, detail design and analysis, component specification, tolerancing (what are the permissible limits in the system where the performance remains acceptable? e.g. mirror tilt ±0.1°?, laser wavelength ±1 nm?) and error budget allocation (for any one tolerance, how much each contributing error is allowed e.g. for laser wavelength, contributions from thermal drift, calibration error, grating fabrication differences etc.), vendor monitoring (checks on one's suppliers), assessment of facilities/equipment, fabrication and inspection of parts, component testing, assembly, alignment and verification. Detailed discussion on the process is available in ref. 183. The process is essentially deciding what is needed and whether it's feasible to meet such needs in a device, followed by a comparison of options and detailed design and testing. One observation we would make is that the barriers to commercialisation often come from unexpected and unforeseen sources, for instance, while focus is often on device performance and the bill of materials required, the engineering may prove problematic, where alignment procedures, say between optical interconnects on-chip, can prove to be prohibitively difficult and thus expensive.
Specific considerations for Raman spectroscopy include optical throughput, spectral range and resolution, requiring compromises when developing a miniaturised system, with different approaches to the size reduction – from optical bench to compact product, or building up from miniaturised components.77 Example subsystems and considerations in this context are outlined in Table 1. While many of the optical aspects of systems engineering in Raman system design are arguably well-appreciated by those in Raman spectroscopy research, as exemplified in a recent review article on laser wavelength use with Raman,21 other aspects pertaining to the electrical, mechanical, and software aspects (see Table 1) may not be.
| Sub system | Optical | Electrical | Mechanical | Software |
|---|---|---|---|---|
| Considerations and requirements | Laser selection: excitation source – power, wavelength, stability, safety | Power consumption: optimise illumination, detection, embedded processing | Compact dimensions: balance performance and size | Rapid data processing and analysis: including software to quickly process spectra and match against databases, algorithms for baseline correction |
| Optical path optimisation: use of fibre-optics, compact optical elements | Embedded computing: potential to embed a compact, efficient processor for real-time data acquisition and analysis | Ruggedisation: withstand relevant environmental conditions – temperature fluctuations, humidity, dust, and physical shocks | AI integration: potential to incorporate AI-based spectral processing –enhance accuracy, automate classification | |
| Detector selection: high sensitivity, low noise, fast response (CMOS, CCD) | Connectivity: low-power, robust connectivity for e.g. cloud-based databases, internet of things integration, real-time updates | Usability: lightweight, easy-to-use controls (support non-expert operators, use by personnel with protective gear) | User interface: intuitive, functional, streamlined interface for operation | |
| Optical filtering: filtering to isolate weak Raman signals (e.g. notch, edge) | Thermal management: appropriate heat dissipation for lasers and detectors – stable operation in various environmental conditions | |||
| Spectral resolution: high resolution Raman peaks – grating selection, optical alignment | ||||
| Background minimisation: mitigate fluorescence via e.g. time gating, excitation wavelength selection | ||||
| SERS substrate selection: maximise SERS signal – enhancement, reproducibility, cost |
Together with outlining and designing the subsystems and interfaces, it is also critical to develop test plans with a view towards verifying that the outlined system requirements are met. Moreover, it is critical to take the perspective of the end user when designing a Raman system, to ensure the developed hardware and software meets the specified requirements, which flow down to the subsystem and component performance. One pertinent example might be analytical sensitivity versus dynamic range, for instance. Here, a user might conceivably be keen on a device operating a wide range of concentrations rather than one achieving the lowest detection limit possible. Similarly, proper quantification is not always needed, instead semi-analytical analyses may be sufficient, supported by a confirmatory second-stage analysis in a lab setting. This might be a good pointer for SERS which, unlike conventional Raman spectroscopy, draws debate over its nature as a properly quantitative technique. Furthermore, Table 1 encompasses a range of general considerations Moreover, a photonic integrated circuit-based Raman system entails many specific details in terms of photonic chip design, testing and verification and relying on a supply chain incorporating design, manufacturing, packaging, testing and system integration.
Evidently, designing an efficient, miniaturised Raman spectrometer requires careful systems engineering. Issues of consistency in final product, which while often a side thought within research, are critical when it comes to the final device equipment. Similarly, while durability and robustness/ruggedness fall distinctly into the later stages of development for products, they are essential for a portable system. Therefore, design of systems is often vastly different enterprise from that of scientific research where many other aspects come into play pertaining to late technology readiness level (TRL), product finalisation stage and end-user requirements, rather than fundamental and exploratory investigation.
Recent advances in digital technologies, particularly in embedded processing, edge computing and cloud-based analytics, are increasingly shaping how miniaturised Raman systems are designed and deployed. However, the growing reliance on software should not be viewed as a substitute for careful optical and systems engineering. While machine learning can compensate for variability to a degree, it cannot recover information that was never captured due to insufficient signal-to-noise, poor spectral fidelity or unstable excitation. In this sense, digital tools are most effective when used to amplify well-designed hardware, rather than to rescue marginal designs. A key systems-level challenge therefore lies in defining clear boundaries between what must be guaranteed by physics and engineering and what can legitimately be delegated to algorithms. As Raman devices move further into non-expert and regulated settings, this distinction will become increasingly important for validation, trust and long-term adoption.
:
1 on standard samples (e.g., polystyrene at 1001 cm−1), which is adequate for identification but can be limiting for trace quantification in complex matrices. On integrated photonic platforms, waveguide-based Raman spectroscopy has achieved limits of detection down to 0.03 mol L−1 (≈0.2 wt%) for isopropyl alcohol in water without any surface-enhancing substrate, illustrating the progress but also the gap to trace-level sensing.
Fluorescence suppression remains pivotal: SERDS can deliver ∼15× improvement in signal-to-background-noise for in-field samples, and recent optimisation studies define practical dual-line wavelength separations (≈2–4 nm at 785–830 nm) for robust reconstruction in highly fluorescent biological tissues. Against these benchmarks, a desired sensitivity for miniaturised, MEMS-enabled Raman can reach <0.01 wt% (100 ppm) in liquids and ppm to sub-ppm in gases for many environmental/biomedical applications; the latter is already routine in integrated photonics using on-chip mid-IR absorption (e.g., 0.3 ppm methane with slot-waveguides), setting an aspirational target for Raman platforms that waveguide Raman seeks to approach through low-loss waveguides, long interaction lengths, and sorbent claddings. Reducing noise levels and improving detection limits require innovations in optical coatings (high-extinction stop-band filters), low-Raman-background materials such as SiN/Ta2O5 and MEMS fabrication techniques (sidewall-roughness control to minimise scattering loss). Additionally, MEMS devices need to endure harsh environments and mechanical stresses, thereby necessitating the use of advanced materials; for example, boron-doped polycrystalline diamond micro-hotplates can operate up to ∼2731 K at ≤100 mW, greatly improving durability/thermal stability for Raman probes and temperature-programmed measurements – but at present they are expensive to manufacture and their extreme-temperature operation must be managed to avoid cumulative graphitisation.
Furthermore, the integration of MEMS devices into complete Raman spectrometers demands precise on-chip alignment/calibration to maintain optical performance; wafer-level sealing, fibre-array attachment, and flip-chip bonding from silicon photonic MEMS platforms are emerging to improve reliability and scalability, while ‘swept-source’ Raman using MEMS-tunable lasers (VCSELs) has demonstrated up to ∼1000× optical throughput gain versus dispersive portable spectrometers at eye-safe powers (∼1.5 mW), shifting complexity from bulky spectrometers to chip-scale light sources and enabling uncooled detectors. Recent advancements also include hybrid MEMS filters capable of operating across multiple wavelength ranges, enhancing the adaptability of Raman devices for diverse applications.54,55 Integration with silicon photonic platforms is emerging as a key trend, where MEMS Fabry–Perot interferometers are combined with waveguides and couplers for fully on-chip Raman spectrometers, reducing alignment complexity and improving robustness. Actuation mechanisms such as electrostatic and piezoelectric drives now enable sub-millisecond tuning speeds, supporting real-time adaptive spectroscopy. High-reflectivity dielectric coatings (e.g., SiO2/Ta2O5 stacks) are being optimised for thermal stability and minimal scattering loss, critical for harsh environments and field deployment.
The availability of low-cost, reproducible components for small Raman devices is being facilitated by developments in lithography, including new techniques that can maintain fidelity at high throughput;8 MEMS are still often fabricated by conventional photolithography in the micron-scale regime184–188 and pushed down to tens of nanometres using X-ray/e-beam patterning,189–192 while nanoimprint lithography (NIL) – which uses an electron beam-made master and an inverse sub-master to emboss nanostructures – has matured industrially for high-throughput, low-cost patterning193 despite early lab-scale imperfections.194 Patterning using additive manufacturing (3D printing) techniques like two-photon polymerisation and stereolithography is not fully industrialised yet, but they show potential for future use with their accuracy and reliability.
However, moving parts as in MEMS devices can be a problem for scalability, which must be considered early-on in any device development endeavour; nevertheless, MEMS-based systems can light the way for more integrated systems, with future scope including full on-chip Raman: monolithic MEMS-tunable lasers, on-chip filters/spectrometers (e.g. multi-aperture SiN FTS with 0.5 nm resolution on 200 mm wafers), integrated detectors, automated alignment, and embedded techniques such as SERDS and SSE (thermal shifted-excitation using micro-heaters) and AI-assisted denoising, all aimed at reaching ppm-level quantitative sensitivity in compact, robust, and manufacturable devices. Smaller spectrometers and MEMS developments within Raman research feed into the ultimate goal of a fully on-chip Raman system, and while challenges persist (fluorescence, filter extinction on chip, detector dark noise, vibration robustness, packaging), the trajectory of integrated photonics and MEMS strongly suggests practical, field-deployable instruments with trace-level sensitivity are within reach.
With respect to system integration, SERS substrates are more likely to persist as modular, replaceable components rather than being permanently embedded within Raman devices. From an engineering and translational perspective, this separation preserves flexibility, reduces system complexity and avoids imposing the material and shelf-life constraints of plasmonic nanostructures on the core optical platform. However, limited forms of integration may still emerge in tightly controlled contexts, for example where SERS structures are confined to sacrificial microfluidic cartridges or disposable sensing heads. In such cases, the Raman system itself remains agnostic to whether enhancement is present, while the SERS element is treated as a consumable assay rather than a permanent optical component. This framing aligns more naturally with existing analytical workflows and cost models and avoids the expectation that SERS must function as a universally quantitative technique across all applications.
Thus, where Raman outshines other spectroscopies is in untargeted detections, where the analyst is working with a complex matrix, or worse, is completely oblivious to unknown substances in a complex environment. Here, Raman scattering spectra, with suitable interpretation, can provide an accurate assessment of the detected compounds.
Raman, categorised alongside mid-infrared spectroscopy, is labelled as mainly qualitative in its application to date, finding uses in pharmaceutical, explosives and narcotics detection. This is in contrast to near-infrared (NIR) absorption spectroscopy, which has found extensive quantitative use, for example in foodstuffs analysis. The lines, however, may be becoming increasingly blurred, and Raman and NIR can be seen as competitors. There is a significant push for Raman spectroscopy to be used as a properly quantitative analytical tool by industry, facilitated by groups, for example, such as the European Union-funded Characterisation and HARmonisation for Industrial Standardisation of Advanced MAterials (CHARISMA) project, seeking to ‘harmonise Raman Spectroscopy for characterisation across the life cycle of a material, from product design and manufacture to lifetime performance and end-of-life stage’.200 There is a particular need for metrological standardisation, particularly for miniaturised systems, with prior standardisation measures having been successfully applied to laboratory-based systems.201 A metrological infrastructure is key to ensure confidence in Raman measurement data, meaning outputs from Raman devices can be accurate and comparable.202 This includes not just wavenumber calibration for example with a certified reference material, but also detector calibration to correct for relative peak intensity differences between different kinds of detectors.201 Progress in Raman standardisation can align with a movement in standardisation in photonics packaging – the integration of optical components into robust, scalable devices assisted by advances in photonic foundries and spurred on by a wide range of applications for optoelectronic systems.28
Hybrid systems are particularly valuable in applications such as space exploration, industrial inspections, biomedical diagnostics, and food safety, where multi-modal analysis can provide more comprehensive insights.204 While arrangements combining SPR and Raman are possible, their implementation is often impractical205 and not enough analytical benefit has been observed to push development beyond academic research. Similarly, multi-wavelength portable Raman systems i.e. more than one laser, or combined IR-Raman systems have not appeared extensively in the market. In the latter case, for example, a cursory search reveals an IR-Raman combo system from BaySpec Inc. (CA, USA).206 Thus, while the combination of different analytical techniques with Raman is undeniably useful, for instance appearing in the agri-food sector,207 the implementation of dual- or multi-spectroscopic systems in one device is perhaps highly specialist in application, limited to niches and custom-built requests, and therefore seemingly unlikely to make widespread market impact for the moment.
Therefore, the development of such devices would appear to fit nicely within the scope of convergence centres which seek to combine different branches of science, across Government, industry and academic partners, aligning with solving a ‘real-world’ problem. While the term convergence might be used, perhaps fairly, in a rather loose fashion to describe any multi-disciplinary effort, it tends to be applied for ventures on the larger scales, less time-bounded projects (or at least with some continuity beyond the original project), and more likely operating at the mid to late TRL scales, for translational research activities, in a more integrated, mission-driven fusion.9 But regardless of the organisation and focus of a convergence centre, what is clear is that more complex interdependent engineering problems require increasingly interdisciplinary co-operations in order to drive devices to market.
This review does not delve into the precise workings of translating Raman research into products (to do so would require a book!) but we note, in brief, some of the complexities in setting up and managing academic–industry partnerships in shared science spaces, including the usual discussions on intellectual property (who owns the research when it's funded by industry? Can it be licenced back to the industry partner and on what terms?). The exact role of the university is a good question – should it be confined to more disruptive R&D or can it overlap with less speculative research activities (fine iterations/optimisations) at the later TRL stages? Can senior academics devote significant time to industry consultancy? And how might these kinds of activities fit in with academic metrics – can translational activities be acknowledged in some way as journal papers and grants are?208 Regardless of the answer to these questions, academic–industry involvements are not just useful but critical to successful device developments, including the multi-faceted domain of miniaturised Raman devices, and may carry with it additional benefits such as graduate students, with key technical knowledge, joining industry partners (or a university spin-out start-up company) post-degree to develop the Raman devices further. We note that the involvement of a spin-out is an especially good idea, rather than established external companies, where start-ups are more likely to prioritise disruptive products, and therefore arguably align more congruently with university R&D activities.208
The nature of the translation from lab-based research at the lower TRL scale to usable products often starts at an early point. Many of the pains of this transition can be smoothed by a sound systems design approach from the outset. Suitable technical oversight, and insight, from the start, is thus critical. While not all potential bumps to commercialisation are foreseeable for specific device developments, many of the problems with taking a Raman device to market can be very general – aspects such as the laser wavelength used and detection efficiency are likely foci in academic research, while later stage developments are more likely to be concerned with aspects such as exact device size, power, and heat management, mechanical alignment, robustness/ruggedness, cost, and regulatory requirements. Thus, there must be a balance between performance and commercial viability.209
![]() | ||
| Fig. 8 Estimation of utility of various biofluids for Raman liquid biopsy to different application areas. CSF = cerebral spinal fluid. | ||
The authors note the recent advent of the Microelectronics UK event in London210 and the co-location of Photonics UK, and Embedded Systems UK, where the synergy of these domains might be key to the advancement of miniaturised photonic systems, including Raman devices. Increased collaboration between academia and industry can be viewed as essential to achieve these aims. This has been evidenced by the UK Government's recent investment on collaborative science in the form of the £42m (∼$56m USD) UK Research and Innovation –funded, Smart Nano NI project in Northern Ireland – one of the UK's constituent regions. The project, of which a number of the co-authors of this paper belong, operates broadly within photonics, nanotechnology and smart manufacturing, represents a paradigm shift in how research and development can work as it has sought to establish an ecosystem within which products can be developed across the technology readiness level (TRL) scale.211
Furthermore, the development of miniaturised spectroscopy is embedded within developments within larger trends within photonics, and materials science. As reported in the recent 2025 UK Photonics Leadership Group report, photonics is gaining significant traction as a field, underpinning some 13% of global innovation,212 of which spectroscopy constitutes a considerable share. In light of this, Innovate UK, a national innovation agency, has recently been holding a series with sector leaders in the form of a Future Tech Deep Dive, including a session focusing on the future of Photonics (October 2025, Belfast, UK) to garner future trajectories in emerging photonic technologies.213 The UK has also recently announced the set-up of a UK Semiconductor Centre as a way to amalgamate current efforts in semiconductor research and draw in external collaboration, for instance South Korea, which may offer manufacturing and scalability capabilities to complement the UK's expertise in research and development and packaging.214
Focus can then be narrowed down from broader photonics to spectroscopy, including Raman devices. As with the portable spectrometer market ($1.7 billion USD, 2020),39 the wider worldwide sensing market is sizable and growing, currently standing above $2 billion USD (2024) with an 9% CAGR projected over the current decade,39 of which Raman devices will garner a significant share. At what scales these devices appear, however, remains to be seen. Often technological advancements do not find extensive use immediately – there is a lack of widespread need. This kind of ‘market lag’ phenomenon is not new. The prime example is Kodak, who developed the first digital camera in 1970s equipped with 100 × 100 pixel CCD and 20 s acquisition time. The 3 kg device however never took off – the memory and semiconductor (CMOS) technology was not ready for such a camera and the market had no need for it.216 While at one point we might have considered the development of miniaturised Raman systems too early – we were waiting for the market need to catch up, the requirement for remote sensing across the various application spheres means the time for small sensing devices is now.
As with other technologies, portable spectroscopic devices follow a familiar path of:
1. Development of the spectroscopic device and proposed applications,
2. Market exposure and feedback,
3. New applications, device refinement (calibrations, algorithms, databases etc.), and
4. Device optimisation/enhancement3
which includes not only portable mini-spectrometers, but those fully integrated to an on-chip level. This application/market-focused process is intricately linked to systems engineering approach, which as we suggest, many aspects of which can all be too easily overlooked by scientists working at early technology development stage.
When it comes to the smallest of Raman systems, their place may be very market-specific. For instance, in a food security context, using Raman spectroscopy for foodstuffs authenticity probably requires hand-held i.e. ∼1 kg devices with easy operation for non-spectroscopy skilled operatives. Contrariwise, applications in decentralised medicine or athletic performance monitoring may require wearable technology that needs to be as small as possible. Similarly, use of Raman sensors for monitoring of explosive precursors217 is likely to require significant miniaturisation for clandestine use.218 Any sensor that needs to be affixed in an elevated place or attached to a drone, say, also needs to be on the lighter side. At present there are multiple areas of research in need of miniaturisation, including Raman device integration into for example, robotic arms during surgeries, in vivo diagnostics, and substance identification at crime scenes.219,220 Adding spectrometers to consumer devices may add too much expense to the consumer without a suitable benefit in performance. One could imagine, for instance, a handheld pen spectrometer device that accurately indicates the freshness state of various foodstuffs, many of which are hard to pinpoint accurately (even with labels), however, this is a level of accuracy that is unlikely to interest most consumers at an elevated price point. Many application areas are still emerging. Within the UK, for instance, as we say, there is a push for more community-driven healthcare screening to relieve pressure from hospitals and studies on new biomarkers amid point-of-care testing continues to abound.221
In the short term, the point-of-care Raman market is unlikely to be driven by further incremental reductions in device size alone. Instead, the dominant trajectory appears to be towards task-specific, application-constrained systems, where optical performance is deliberately matched to a narrow diagnostic question rather than designed for broad analytical flexibility. In practice, this means accepting reduced spectral range or resolution where it does not materially impact diagnostic accuracy, in exchange for lower cost, faster acquisition and simpler regulatory validation. In healthcare settings in particular, PoC Raman devices are likely to succeed where they replace or de-risk an existing workflow, rather than where they attempt to introduce a new one. This favours devices targeted at well-defined use cases such as triage, screening or longitudinal monitoring, rather than general-purpose molecular analysis. As such, future PoC Raman systems may look less like miniaturised laboratory instruments and more like embedded diagnostic tools, co-designed with clinicians, regulators and end-users from the outset.
However, the bar for entering some sectors can be prohibitive for some investors. Healthcare devices, which are the focus for many Raman researchers, are higher risk and require a financial investment model that allows for a protracted product development.28 New medical devices now must conform to more stringent standards,222 which requires greater collaboration between developers and medical professionals. Within this application area specifically, a further problem is that the detection of biomarkers has been historically scattered and studies have lacked clinical validation. This may mean funders need to require a more concerted effort from researchers at the low TRL-range in order to facilitate effective device development at the later TRL stages.221
Elsewhere, the food supply has become increasingly globalised and this has mandated more portable sensing at various nodes in the chain to test the authenticity of what arrives on our supermarket shelves. Especially prominent events, such as the COVID19 pandemic (2019–2022) or the UK Horsemeat Scandal (2013)223 can be a real gamechangers for technology development, similar perhaps in how World War 2 resulted in significant strides in near-infrared devices. With climate change, environmental monitoring continues to be a concern, and the rise of AI and smart factories has also brought with it increased sensors needed for industrial quality control.
Moreover, different regions may have different strengths, and progress in the various areas that constitute making a Raman device could look different. The MATRIX report looking at photonics technologies points out that certain regions can have niches or competitive advantages due to existing capabilities or lack of competition in some photonics sectors. The report, for example, highlights the UK, South Korea and Australia as having particular expertise in spectroscopy and biophotonics (both $121 USD global market growth projection 2023–2030).215
Thus, predicting the precise trajectory for Raman miniaturisation is challenging (Fig. 9). It is hence important to keep talking to the analytical market to see what they want.225 Should the place for miniaturised Raman become clearer, there will be a need to keep adjusting to requirements for different applications: exact footprint and mass, resolution and wavelength range covered etc., aligning with what an end user, perhaps even a consumer, would be willing to pay. It is now approaching 100 years since CV Raman discovered his eponymous effect (1928) and the progress that has been made has been remarkable where Raman spectroscopy has found a variety of applications, and spawned a range of derivative research areas, some of which, like SERS, have now become expansive fields of their own. Raman systems have seen impressive progress in miniaturisation. Perhaps the next century of Raman will deliver a range of devices, of different sizes and forms, to serve current application spaces and potentially a few new ones too.
Supplementary information (SI): the SI provides a comparison of charge-coupled device (CCD) and complementary metal oxide semiconductor (CMOS) sensors (Table S1) and a comparison of selected portable/carriable Raman systems (Table S2). See DOI: https://doi.org/10.1039/d5lc00836k.
| This journal is © The Royal Society of Chemistry 2026 |