Shape memory alloy (SMA)-reinforced self-healing metal matrix composites (SHMMCs) are an emerging class of materials capable of semi-autonomously repairing cracks—a process termed assisted self-healing, offering significant potential for enhancing structural longevity. This study investigated the effects of varying SMA volume fractions (1.5 and 4.2 vol%) and in situ low melting point phases (15 and 40 wt% tin) on the self-healing performance of the aluminum matrix composites. Additionally, the study investigates the influence of a clamping mechanism and the use of etchants and a phosphoric acid-based flux on enhancing load transfer and improving healing efficiency in NiTi SMA-reinforced SHMMCs. Flexural testing confirmed the restoration of mechanical properties after healing, while microstructural characterization using Scanning Electron Microscopy (SEM) and Energy Dispersive Spectroscopy Analysis (EDS) revealed interfacial bonding between the Al–Sn matrix and NiTi reinforcement. Among the tested compositions, the Al–40 wt% Sn–1.5 vol% NiTi composite without a clamping mechanism exhibits the highest flexural property recovery, attributed to the synergistic effect of shape restoration by the NiTi SMA and effective sealing of the healing agent at the crack site. These findings highlight the potential of SMA-reinforced SHMMCs for enhancing material durability and sustainability.
Manuel et al.6,7 synthesized SMA-reinforced SHMMCs using Sn–Bi and Mg–Zn–Al matrices with ∼1 vol% continuous NiTi wires, achieving near-full tensile strength recovery in Sn–Bi but only partial closure of crack in the stronger Mg alloy where SMA force was insufficient to close rough crack surfaces. Misra et al.1,29,30 employed pressure-infiltrated Sn–Bi/Bi–Sn matrices with ∼20 vol% NiTi to obtain complete crack closure, full shape recovery, and high flexural strength recovery (92% for Sn–20% Bi–NiTi and 88% for Bi–10% Sn–NiTi). Wright et al.20 demonstrated that microstructure and matrix ductility govern healing efficiency: Al–Si/NiTi composites retained ∼90% UTS after healing, whereas Al–Cu-based systems showed little healing due to insufficient ductility of the matrix preventing effective SMA transformation. Fisher et al.17,23 embedded 2 vol% NiTi in Al–Si and reported ∼92% tensile healing efficiency, with evidence of fatigue-crack healing. Poormir et al.24,31 and Srivastava et al. showed33–39 that SMA volume fraction, pre-strain, healing temperature, healing time, and solder reservoirs all play important roles in self-healing. Sharma et al.40,41 demonstrated that in semi-solid processed composites partial crack closure occurs in short times. Zhu et al.18,28 confirmed through modeling that pre-strain and matrix softening are important for healing. Manuel et al.22 proposed that negative-CTE reinforcements could be used as an alternative to SMA. Tasan et al.5 suggested that SMA nanoparticles might enable autonomous nanoscale healing, but this has not yet been experimentally verified.
An alternative approach to healing involves ex situ healing agents encapsulated in tubes, capsules, or microballoons, which release low-melting-point healing liquids such as Sn, In, Zn, Sn–Bi, Sn–Pb, or Zn–Al upon rupture at healing temperature.42–48 These healing agents are incorporated into metal matrices (e.g., Al, Al206, Al5083, Sn, or Sn–Cu alloys) via conventional solidification techniques42–48 or, more recently, through additive manufacturing.49 These studies did not report recovery of mechanical properties during healing. Moreover, this method faces several challenges, including difficulties in uniformly embedding the capsules, as well as issues related to surface tension, capillarity, and viscous resistance, which hinder the healing liquid from entering cracks, forming effective bonds, and achieving reliable healing. Since the healing process depends on the rupture of encapsulated agents, cracks occurring in regions without capsules remain unhealed, resulting in inconsistent and location-dependent performance. Additionally, voids left after agent release can compromise mechanical integrity. These systems are typically limited to single-cycle healing, as once the agent solidifies within a crack, the original capsule sites remain voided, reducing structural strength and precluding further healing without additional processing.50
To address these limitations, in situ low-melting-point phase-based SMA-reinforced SHMMCs offer an advanced approach to self-healing. In these systems, the low melting point phase is formed or retained within the matrix during fabrication, similar to metallic composite phase change materials,51–54 thereby eliminating the need for externally encapsulated healing agents. This enhances the scalability and practicality of the self-healing mechanism. The embedded in situ low-melting-point phase acts as a healing agent, melting at a temperature lower than that of the matrix, flowing into cracks, and subsequently solidifying to restore structural integrity. Unlike eutectic-based self-healing, the healing process in this system occurs at substantially lower temperatures. The use of an in situ low-melting-point phase is particularly advantageous, enabling healing with reduced thermal input. This promotes energy conservation during the healing cycle and facilitates the potential application of novel techniques, such as electro-healing, to repair the composites. Designing the composite microstructure to optimize the flow of this healing phase is crucial to achieving efficient crack filling and strength recovery.
Previous research by Jeong et al.52 demonstrated self-healing capabilities in (Al81Cu13Si6)100−x(Sn57Bi43)x (x = 1 and 3 at%) composites, where dual self-healing properties were observed through precipitate formation and in situ low-melting-temperature metallic healing agents. However, these composites did not incorporate SMA reinforcements. By integrating SMA within a matrix containing an in situ low melting point phase, it is possible to leverage the shape memory effect for enhanced healing efficiency. The compressive force exerted by the SMA during phase transformation reduces crack size, facilitating the filling of smaller cracks compared to macro-scale defects. This synergistic approach holds significant promise for improving self-healing efficiency and mechanical performance in SHMMCs.
In this study, the design, synthesis, and self-healing performance of SMA-reinforced aluminum–tin (Al–Sn) matrix composites are investigated, with tin functioning as an in situ low-melting-point healing phase (melting at 228 °C). The key self-healing mechanisms—including crack narrowing and closure, strength, modulus, toughness recovery, and shape restoration—are analyzed and experimentally validated. A comprehensive microstructural analysis of the self-healing Al–Sn composites is conducted, with particular focus on interfacial bonding between the NiTi fibers and the matrix. Additionally, the effects of a mechanical clamping system for securing the NiTi SMA wires, as well as the use of etchants and phosphoric acid-based flux to enhance bonding and improve healing efficiency, are investigated. The influence of different SMA volume fractions (1.5 and 4.2 vol%) and in situ low-melting-point phase contents (15 and 40 wt% Sn) on self-healing performance is systematically evaluated. Bending tests are performed to assess crack closure, flexural property recovery, and shape restoration, ensuring that the induced strain remains within the elastic range of the SMA to maximize recovery. By integrating SMAs with in situ low-melting-point healing phases, this research advances the development of next-generation self-healing metallic materials, offering enhanced durability, repairability, and energy efficiency for structural applications.
• The wires were first immersed in an aqueous solution containing 4.8% HF and 10.5% HNO3 for 5 minutes to etch the surface.
• To remove residual flux, the etched wires were sequentially rinsed in two HDPE bottles filled with distilled water for 30 minutes and 15 minutes, respectively.
• Following rinsing, the wires were treated (pickled) in a phosphoric acid-based commercial flux, Indalloy Flux #2 (Indium Corporation of America), for 3 minutes.
• After fluxing, the wires were placed in an empty HDPE bottle for 30 minutes to dry and stabilize the treated surface.
The etched and fluxed NiTi wires were then wrapped around the SMA clamping mechanism, as shown in Fig. 1(b). Permanent mold gravity die casting was used to fabricate the samples. A suitable amount of aluminum (purity 99.8%) and tin (purity 99.9%) was melted in a graphite crucible using a TOAUTO 3KG Gold Melting Furnace (TGF3000, 1400 W, 2000 °F Digital Electric Melting Furnace) at 750 °C. The Al–Sn melt was then poured over the NiTi wires (50–50 at% from Dynalloy) and allowed to cool. The cast sample with the clamping mechanism is shown in Fig. 1(c). After casting, the samples were machined to the dimensions provided in Table 1. Fig. 1(d) shows the machined sample with the clamping mechanism.
Sample id | Sn (wt%) | NiTi (vol%) | Dimensions (l × b × h) (mm3) | Clamping mechanism |
---|---|---|---|---|
Al15Sn4.2NiTiWC | 15 | 4.2 | 60 × 23 × 7 | No |
Al15Sn4.2NiTi | 15 | 4.2 | 78 × 23.5 × 9 | Yes |
Al40Sn1.5NiTi | 40 | 1.5 | 77 × 23 × 7 | Yes |
Al40Sn1.5NiTiWC | 40 | 1.5 | 60 × 23 × 7 | No |
The identification of the synthesized samples is provided in Table 1.
Samples containing 15 wt% Sn were reinforced with a higher volume fraction of SMA wires to promote effective crack closure, thereby allowing the low-melting-point phase to fill and seal the cracks. Conversely, samples with 40 wt% Sn incorporated a lower SMA volume fraction. This approach ensures that a sufficient quantity of liquid phase remains available to accommodate larger crack openings during healing. Tin was chosen as the in situ low-melting-point phase because of its relatively low melting temperature compared to conventional eutectic phase-based aluminum alloys. Fig. S3 presents the DSC analysis of Al–15 wt% Sn, Al–40 wt% Sn, and NiTi. The DSC results for NiTi reveal an austenite start temperature of 59.8 °C and a finish temperature of 77.3 °C, with martensite start and finish temperatures of 61.3 °C and 45.9 °C, respectively. These findings confirm that NiTi exhibits the reversible phase transformations required for healing. Upon crack formation, twinned martensite transitions to detwinned martensite. Heating initiates a transformation to austenite, and subsequent cooling restores the original twinned martensite structure, aiding shape and crack closure recovery. The DSC curves for Al–15 wt% Sn and Al–40 wt% Sn indicate tin-rich liquid phase melting at 230.4 °C and 233.4 °C, respectively, confirming the availability of a liquid healing phase. The larger integrated area of the melting peak observed in Al–40 wt% Sn indicates a higher fraction of molten Sn-phase, which may enhance healing efficiency. SEM and EDS characterization of Al–15 wt% Sn–NiTi and Al–40 wt% Sn–NiTi composites verified the elemental composition of both matrix and reinforcement. Tin enrichment at grain boundaries was observed (Fig. S4–S7), with tin content increasing progressively from ∼10 wt% in Al–15 wt% Sn to ∼40 wt% in Al–40 wt% Sn. The presence of tin at grain boundaries is associated with improved ductility of the composites. To further quantify the distribution of tin within the matrix, EDS area analysis was carried out on multiple regions of the Al–15 wt% Sn and Al–40 wt% Sn composites. For Al–15 wt% Sn, the Sn concentration averaged ∼10.5 wt% with a narrow standard deviation of 0.93 wt% (Fig. S8). In the Al–40 wt% Sn composite, the Sn concentration averaged ∼33.6 wt% with a slightly higher standard deviation of 5.85 wt% (Fig. S9). Overall, the distribution of Sn in both compositions is macroscopically uniform across the matrix. Lower than expected Sn levels can be due to the use of standardless quantification routines in the software and the nature of EDS quantification difficulties when the sample contains elements of vastly different atomic weights such as is the case with Al and Sn.56
Surface treatment of NiTi wires through etching and fluxing produced a roughened surface morphology, as shown in Fig. S10, which enhances mechanical interlocking with the matrix, promoting efficient load transfer and improved healing performance. In addition, fluxing treatment also improves interfacial wettability by dissolving the native oxide layer on NiTi and increasing the surface energy, which promotes better spreading of the molten Al–Sn phase on the reinforcement.29,57–60 Enhanced wetting between the NiTi fiber and Al–Sn matrix and mechanical interlocking between the roughened surface of the fiber and the matrix led to load transfer between the NiTi fibers and the matrix and the fiber pullout is prevented. Between Al–15 wt% Sn and NiTi, the aluminum–tin alloy (whether Al–15 wt% Sn or Al–40 wt% Sn) has a higher thermal coefficient of expansion (CTE). Al–15 wt% Sn has a CTE of approximately 23–25 × 10−6/°C, while Al–40 wt% Sn can be estimated to be in the range of 25–27 × 10−6/°C.61,62 In contrast, NiTi has a CTE of approximately 11–12 × 10−6/°C in the austenite phase and 6–8 × 10−6/°C in the martensite phase.63 This difference in CTE causes the matrix in the composite to shrink radially more than the fiber upon cooling from a high temperature. Good contact between the NiTi and the matrix is observed, as shown in Fig. S4–S7 and 2. Effective mechanical bonding requires that the matrix fill the hills and valleys on the surface of the reinforcement and this is facilitated by good wetting. Furthermore, some reaction bonding also occurs at the interface, as demonstrated in Fig. 2. The reaction zone, consisting of Al, Sn, Ni, and Ti, indicates transport of atoms and their reaction at the interface. Fig. 2 illustrates how the asperities in the NiTi are filled by the matrix, along with evidence of chemical reactions at the interface. The combined effects of mechanical interlocking and reaction bonding contribute to the overall bond strength. Achieving optimal bonding facilitates efficient load transfer between the matrix and reinforcement and improves healing efficiency. Collectively, the rough topography, thin reaction interlayer, and CTE-induced shrink-fit are consistent with a shear-lag load-transfer mechanism that suppresses interfacial slip. During healing, the same bonded, well-wetted interface efficiently transmits NiTi recovery stresses to deform the matrix and narrow and close the crack.
The healing efficiency of the SHMMC is assessed by comparing the flexural properties (FP) of the virgin composite with the post-healing flexural properties of the same composite, using eqn (1):
![]() | (1) |
The flexural stress vs. strain graph for the self-healing aluminum–tin composite samples is depicted in Fig. 3, and the results are presented in Table 2. Among all the tested samples, the Al40Sn1.5NiTi exhibited the highest flexural strength. The inclusion of a clamping mechanism enhanced the strength of the samples for both the Al–40 wt% Sn and Al–15 wt% Sn matrix materials. Furthermore, the addition of tin to aluminum improved the flexural toughness of the samples. Fig. 4(a) and (b) show the flexural strength and specific flexural strength of the intact and healed composite samples with varying tin content, NiTi volume fractions, and the presence or absence of a clamping mechanism, while Table 2 presents their flexural strength recovery and specific flexural strength recovery, respectively. The flexural strength recovery of the SMA-reinforced self-healing aluminum–tin composites provides insight into the effectiveness of the self-healing mechanism. Among the four tested samples, the Al40Sn1.5NiTiWC composite (40 wt% Sn, 1.5 vol% NiTi, without clamping) exhibited the highest flexural strength recovery (90%), demonstrating the advantage of incorporating a high Sn content in the matrix. The enhanced healing efficiency can be attributed to the greater availability of the low-melting-point Sn phase, which effectively filled and sealed the cracks upon heating. Conversely, the Al15Sn4.2NiTi composite (15 wt% Sn, 4.2 vol% NiTi, with clamping) exhibited the lowest strength recovery (44.58%), highlighting the potential limitations of using a lower Sn content combined with a higher NiTi volume fraction. This suggests that, while the shape memory effect of NiTi contributes to crack closure, the absence of sufficient healing liquid from Sn may hinder complete crack filling and sealing, ultimately affecting the strength recovery. Moreover, while the clamping mechanism improved the initial intact flexural strength of the samples, it had a negative impact on healing efficiency due to the introduction of a weak point in the structure, where Sn may have preferentially flowed, thereby reducing the effectiveness of the healing process.
Sample id | Flexural strength | Specific flexural strength | % Strength and specific flexural strength recovery | ||
---|---|---|---|---|---|
Intact sample (MPa) | Healed sample (MPa) | Intact sample (103 N m kg−1) | Healed sample (103 N m kg−1) | ||
Al15Sn4.2NiTiWC | 47.8 | 28.7 | 12.9 | 7.74 | 60 |
Al15Sn4.2NiTi | 57.26 | 25.53 | 17.7 | 7.9 | 44.6 |
Al40Sn1.5NiTi | 75.15 | 43.43 | 21.1 | 12.2 | 57.8 |
Al40Sn1.5NiTiWC | 56.3 | 50.7 | 14.9 | 13.4 | 90 |
Fig. 4(c) and (d) show the flexural modulus and specific flexural modulus of the intact and healed composite samples with varying tin content, NiTi volume fractions, and the presence or absence of a clamping mechanism, while Table 3 presents their flexural modulus recovery and specific flexural modulus recovery, respectively. The flexural modulus and specific flexural modulus recovery results indicate that, while healing restored strength to some extent, the stiffness of the material was significantly reduced after healing. This suggests microstructural changes that impact the load-bearing capability of the composite post-healing. The highest flexural modulus and specific flexural modulus recovery were observed in the Al15Sn4.2NiTiWC composite (43.3%), indicating that a lower Sn content and absence of clamping helped retain structural stiffness after healing. Conversely, the Al40Sn1.5NiTiWC composite exhibited the lowest flexural modulus and specific flexural modulus recovery (23.1%), suggesting that while a higher Sn content improves crack sealing and strength recovery, it reduces stiffness post-healing. This may be due to the redistribution of the Sn phase after healing, leading to localized softening in the matrix. Overall, increasing the NiTi volume fraction led to improved flexural modulus and specific flexural modulus recovery. These findings imply that, while a higher Sn fraction enhances healing efficiency in terms of strength recovery, it introduces a trade-off in terms of stiffness loss.
Sample id | Flexural modulus | Specific flexural modulus | % Flexural modulus and specific flexural modulus recovery | ||
---|---|---|---|---|---|
Intact sample (103 MPa) | Healed sample (103 MPa) | Intact sample (106 m2 s−2) | Healed sample (106 m2 s−2) | ||
Al15Sn4.2NiTiWC | 3 | 1.3 | 0.81 | 0.35 | 43.3 |
Al15Sn4.2NiTi | 9.3 | 3.8 | 2.9 | 1.18 | 40.8 |
Al40Sn1.5NiTi | 12.2 | 4 | 3.4 | 1.12 | 32.8 |
Al40Sn1.5NiTiWC | 9.1 | 2.1 | 2.4 | 0.56 | 23.1 |
Fig. 4(e) and (f) show the flexural toughness and specific flexural toughness of the intact and healed composite samples with varying tin content, NiTi volume fractions, and the presence or absence of a clamping mechanism, while Table 4 presents their flexural toughness recovery and specific flexural toughness recovery, respectively. The analysis of flexural toughness recovery provides critical insights into the damage tolerance and energy absorption capacity of the healed samples. The Al40Sn1.5NiTiWC composite demonstrated the highest flexural toughness and specific flexural toughness recovery (59.2%), highlighting that a higher Sn content facilitates a more effective crack-sealing process. The ability of the Sn phase to flow into cracks and resolidify plays a crucial role in restoring the material's resistance to fracture. In contrast, the Al15Sn4.2NiTiWC composite exhibited the lowest toughness recovery (26.7%), suggesting that a lower Sn content may not provide sufficient healing liquid to fill and seal cracks effectively, leading to a lower degree of toughness restoration. Interestingly, the toughness recovery was higher in the Al40Sn1.5NiTi samples compared to the Al15Sn4.2NiTi samples, reinforcing the hypothesis that increasing the in situ low melting point phase contributes positively to damage recovery.
Sample id | Flexural toughness | Specific flexural toughness | % Flexural toughness and specific flexural toughness recovery | ||
---|---|---|---|---|---|
Intact sample (106 J m−3) | Healed sample (106 J m−3) | Intact sample (103 m2 s−2) | Healed sample (103 m2 s−2) | ||
Al15Sn4.2NiTiWC | 2.4 | 0.64 | 0.66 | 0.17 | 26.7 |
Al15Sn4.2NiTi | 1.98 | 1.08 | 0.61 | 0.34 | 54.5 |
Al40Sn1.5NiTi | 5.4 | 2.37 | 1.53 | 0.67 | 43.9 |
Al40Sn1.5NiTiWC | 5.2 | 3.08 | 1.37 | 0.82 | 59.2 |
The clamping mechanism was introduced to improve load transfer between the NiTi wires and the aluminum matrix. While clamping enhanced the initial intact strength of the composite by reinforcing the material structure, the presence of a clamping reduced flexural strength recovery. Fig. S11(a) shows an optical image of the area near the clamp before healing, and Fig. S11(b) shows the corresponding area after healing, where Sn-rich healing agent is visible around the clamp. Fig. S11(c) presents a microstructural SEM image of the clamp region before healing, while Fig. S11(d) shows the microstructural SEM image after healing along with EDS analysis of the healing agent. These results indicate that although clamping improves mechanical integrity before damage occurs, there was seeping of tin around the clamping bar, and this may have an effect of the strength of the healed sample. More systematic studies are needed to understand the effect of clamping on recovery of strength on healing.
The crack area of the samples was measured before and after healing using ImageJ software. For Al15Sn4.2NiTiWC, the crack area before healing was found to be 6.8 mm2. After healing, the crack area was reduced to 3 mm2, resulting in a percentage reduction of 55.9%, as shown in Fig. S12. The percentage reduction in crack area is calculated using the following eqn (2):
![]() | (2) |
For Al15Sn4.2NiTi, the crack area before healing was 16.3 mm2, and after healing, it was reduced to 9.7 mm2, yielding a percentage reduction of 40.5%, as shown in Fig. S13. For Al40Sn1.5NiTi, the crack area before healing was 27.3 mm2, and after healing, it was reduced to 5.2 mm2, resulting in a percentage reduction of 81%, as shown in Fig. 5. For Al40Sn1.5NiTiWC, the crack area before healing was 19.8 mm2, and after healing, it was reduced to 9.4 mm2, leading to a percentage reduction of 52.5%, as shown in Fig. S14. The highest reduction in crack area was observed in sample Al40Sn1.5NiTi, which can be attributed to the synergistic effect of NiTi wire and crack sealing by the low melting point tin phase.
The analysis of crack area reduction in self-healing aluminum–tin composites reveals that a higher Sn content (40 wt%) significantly enhances crack-narrowing healing efficiency, as observed in the Al40Sn1.5NiTi sample, which exhibited the highest crack area reduction of 81%. This superior healing performance is attributed to the increased availability of low-melting-point Sn, which effectively flows into cracks and seals them upon heating, combined with matrix softening at the healing temperature. Additionally, the synergistic effect of NiTi reinforcement played a crucial role in facilitating crack closure, as the shape memory effect of NiTi induces compressive stresses that aid in the healing process. Conversely, samples with lower Sn content (15 wt%) exhibited lower healing efficiency, with Al15Sn4.2NiTi achieving only 40.5% crack area reduction, indicating that insufficient healing liquid and reduced matrix softening at the healing temperature limit the crack-sealing capability. Similarly, Al15Sn4.2NiTiWC showed a 55.9% crack area reduction, reinforcing the need for an optimal Sn percentage in self-healing aluminum–tin composites.
The highest strength recovery was observed in the Al40Sn1.5NiTiWC. This significant recovery is attributed to the effective bonding of the healing agent within the crack area, as illustrated in Fig. S15. Elemental analysis of the sealing material in crack shows that it mainly consists of tin with low levels of aluminum. Evidence of some oxide was found at the crack site even though the present healing experiments were conducted in an inert atmosphere to minimize oxidation. Real service environments may expose the material to air or moisture, where extensive oxidation can possibly occur and this will need further investigation to quantify the effect of oxidation under different geometrical and environmental conditions.
The percentage of shape restoration for the healed samples was measured using the following eqn (3):
![]() | (3) |
The analysis of shape restoration in self-healing aluminum–tin composites (as presented in Fig. 6(a) and (b)) reveals that the Al15Sn4.2NiTiWC sample exhibited the highest percentage of shape restoration (99.9%), indicating superior shape recovery after healing. This can be attributed to its lower ductility, which results in less severe bending before failure, allowing for a greater degree of shape retention post-healing. When comparing shape restoration between Al15Sn4.2NiTi and Al40Sn1.5NiTi, it was observed that Al40Sn1.5NiTi exhibited a slightly higher total shape restoration (6.6°) compared to 4.9° for Al15Sn4.2NiTi. This trend suggests that matrix softening at the healing temperature played a role in shape recovery for Al–40 wt% Sn samples. Overall, the results indicate that higher NiTi volume fractions enhance shape recovery due to the shape memory effect, while higher Sn content influences matrix softening, leading to variations in the degree of restoration. However, the combination of NiTi reinforcement and in situ low-melting-point Sn phase remains essential for optimizing self-healing performance in aluminum composites.
![]() | ||
Fig. 6 Shape restoration of self-healing aluminum–tin (Al–Sn) composites: (a) optical images of samples before and after self-healing; (b) graph comparing shape restoration. |
It should be noted that the present study was restricted to a single healing cycle for each composite. Nevertheless, the design inherently offers the potential for repeated healing. The in situ Sn phase remains within the matrix as shown in Fig. S11 and can re-melt and resolidify during subsequent cycles, though its availability will gradually diminish as it is consumed at crack sites. The NiTi reinforcement retains its reversible phase transformation capability, but cyclic straining within the constraints of the matrix may induce fatigue and functional degradation, potentially limiting multicycle healing.64,65 Systematic multi-cycle healing studies are required to examine the potential of multicycle healing in the composites.
In the context of phase-change material (PCM)-assisted self-healing metals, our SMA-reinforced Al–Sn/NiTi composites achieve near-complete shape restoration (up to 99.9%), high strength recovery (up to ∼90%), and up to ∼81% reduction in crack area after a single healing cycle. Dual in situ PCM designs (e.g., Al–Cu–Si with Sn–Bi) demonstrate thermally/warm-rolling-assisted crack (up to ∼28 μm) filling at ∼150 °C, though mechanical property recovery is not quantified.52 In a binary Al–4.28 wt% Sn alloy, annealing at 400 °C for 30 min enabled Sn-rich eutectics to fill >90% of an artificial crack (∼5 μm wide, ∼1.6 mm long), resulting in a >120% increase in ductility compared with pure Al.54 A key difference is the mechanism: SMA-assisted healing not only provides active recovery stresses that clamp and narrow cracks but also enables sealing of larger cracks that would be inaccessible to PCM alone, ensuring robust shape restoration and effective post-healing load transfer. PCM-only approaches rely primarily on capillarity and diffusion and may benefit from external pressure or deformation (e.g., rolling). While PCM routes can operate at lower temperatures, SMA-assisted systems combine crack-closure forces with melt-assisted sealing, offering clear advantages where shape restoration and structural recovery are critical.
The self-healing capability in Al–Sn–NiTi reinforced components will prevent catastrophic failures and extend the life and functionality, thereby reducing the need for replacement parts. This would reduce the need for materials and energy requirements to produce replacement parts and promote sustainability.
Supplementary information: includes an image of the box furnace used for healing; Al–Sn phase diagram; DSC curves of NiTi, Al–15 wt% Sn, and Al–40 wt% Sn; SEM and EDS microstructural analyses of Al–15 wt% Sn–NiTi and Al–40 wt% Sn–NiTi; an SEM image of the NiTi wire surface after etching and fluxing treatment; optical and SEM images of the region near the clamp before and after healing; EDS analysis of the healing agent near the clamp after healing; SEM micrographs of the crack area before and after healing in tested specimens with corresponding ImageJ analyses; and EDS elemental analysis confirming bonding of the healing agent within the crack area. See DOI: https://doi.org/10.1039/d5ta05255f.
This journal is © The Royal Society of Chemistry 2025 |