Jan
Nawrocki
a,
Vishnu
Anilkumar
a,
Guobin
Jia
b,
Apurba
Mahapatra
*a,
Piotr
Bernatowicz
a,
Jan
Dellith
b,
Gayatri
c,
Mateusz
Raczyński
c,
Arka
Karmakar
c,
Pankaj
Yadav
d,
Seckin
Akin
e,
Benjamin
Dietzek-Ivanšić
b,
Maciej R.
Molas
c,
Jonathan
Plentz
b and
Daniel
Prochowicz
*a
aInstitute of Physical Chemistry, Polish Academy of Sciences, Kasprzaka 44/52, 01-224 Warsaw, Poland. E-mail: amahapatra@ichf.edu.pl; dprochowicz@ichf.edu.pl
bLeibniz Institute of Photonic Technology (Leibniz IPHT), Albert-Einstein-Strasse 9, 07745 Jena, Germany
cInstitute of Experimental Physics, Faculty of Physics, University of Warsaw, 02-093 Warsaw, Poland
dDepartment of Solar Energy, School of Energy Technology, Pandit Deendayal Energy University, Gandhinagar-382 007, Gujarat, India
eDepartment of Metallurgical and Materials Engineering, Necmettin Erbakan University, Konya, 42090, Turkey
First published on 17th April 2025
Lead halide perovskite quantum dots (QDs) have emerged as next-generation materials for photodetectors (PDs). It is well known that conventional alkyl long-chain ligands show weak binding on the surface of the QD core, leading to low stability and poor charge transfer. Herein, we explore the effect of partial replacing of alkyl long-chain ligands with aromatic short-chain ligands, namely phenylethylamine (PEA) and trans-cinnamic acid (TCA), on the performance of CsPbBr3 QDs-based PD deposited on textile. The planar-type PDs with optimum PEA (L-type) and TCA (X-type) ligand doping concentration show improved performance compared to the control device due to the combined effect of enhanced conductivity and photoluminescence lifetime, lower surface defect centres, and reduced non-radiative recombination. Notably, PEA-treated CsPbBr3 QDs-based PD shows the best photodetection properties of blue light (448 nm) at 10 V with a peak responsivity of 149 mA W−1 and EQE of 41.3%, which is almost 20 times higher than those of the control device and 3 times higher than the TCA-treated CsPbBr3 QDs based device. In addition, this device reveals excellent mechanical and operational stability. These results pave the way for designing flexible and wearable perovskite QDs-based optoelectronic devices, which may find potential applications in future optoelectronic devices.
The important components of LHP QDs are organic capping ligands, which play an essential role in modulating stability and optoelectronic properties including charge carrier transport.27 The most widely used capping ligand for colloidal perovskite QDs is the pair of oleic acid and oleylamine, whose long-chain insulating character hinder the improvement of device performance.28 To address this issue, Zhou et al. proposed the use of mesoporous TiO2 (mp-TiO2), which acts as a scaffold material capable of extracting charge carriers from the QDs.29 The PD device based on a bilayer composite mp-TiO2/CsPbBr3 QDs exhibits a significantly enhanced performance than the pure QDs-based device, showing three orders of magnitude higher on/off ratio and a 44-fold increase in responsivity. Similarly, the hybridization of LHP QDs with graphene appears as a convenient method to create high-performance PDs by promoting the separation of photoinduced electron–hole pairs.30–32
Another approach for the development of efficient LHP QDs-based devices is surface ligand-shell engineering. Particularly, the introduction of short-chain ligands containing functional groups was reported not only to improve the charge carrier transport but also to maintain the colloidal stability and passivate diverse defect sites of LHP QDs.27 For example, Vickers et al. demonstrated that the incorporation of short conductive aromatic ligands such as benzoic acid and benzylamine on the surface of QDs facilitates charge transport due to efficient surface passivation of defect regions and delocalization of the electronic wave function from the QDs.33 The organic shell modification with short-chain aromatic ligands was also discussed by Wang et al.34 It was demonstrated that the addition of benzyl iodide not only passivates the surface defects but also realizes p-doping character, which shifts the positions of the valence band and significantly reduces the hole injection barrier in devices. In another work, Yan et al. reported on an in situ polymerization method of 3,4-ethylenedioxythiophene on a surface of CsPbBr3 QDs under the photocurrent of the PD.35 The introduction of an aromatic polymeric shell to cross-link the LHP QDs enhances the conductivity and allows for high moisture resistance of the device. These studies and many others36–39 have proven that surface treatment engineering with various ligands plays a significant role in the LHP QDs colloidal stability, morphology and photoluminescence properties. On the other hand, the effect of different ligand types on the performance of PDs based on colloidal LHP QDs has been little explored to date.25 It is well known that surface ligands can be defined as types L, X, or Z according to coordination chemistry.40 Typically, X-type ligands donate one electron to form metal–ligand bond, while L-type ligands are neutral two-electron donors with a lone electron pair that coordinates with surface cations. Therefore, we posit to investigate the influence of short-chain capping ligands, chosen judiciously with similar size but varied type (X- or L-type) and functionality, on the photodetection figure of merits of CsPbBr3 QDs-based devices.
In this study, we selected aromatic short-chain ligands such as phenethylamine (PEA) and trans-cinnamic acid (TCA) as typical L- and X-type ligands to modify CsPbBr3 QDs shell, respectively. First, we synthesized CsPbBr3 QDs whose organic shells were modified with PEA and TCA capping ligands using a ligand-assisted reprecipitation (LARP) technique. The resulting materials were structurally and spectroscopically characterized, and their morphology was determined by transmission electron microscopy (TEM). In addition, we discussed the composition and interaction of the organic shell with the QD core using 1H NMR and 1H NOESY NMR spectroscopies. Then, after optimizing the ligand concentration on the surface of QDs, we prepared and fully characterized the photoconductor-type PD deposited on a flexible textile substrate. Our results reveal that the PEA-treated CsPbBr3 QDs film gives rise to better charge transport with improved PL lifetime, lower surface defect centres, and reduced non-radiative recombination compared to the reference film. However, despite the enhanced conductivity in the TCA-treated CsPbBr3 QDs film, the higher level of non-radiative recombination, defects, and second-order charge recombination restricts its performance compared to the PEA-treated CsPbBr3 QDs-based PD. The PEA-treated CsPbBr3 QDs-based PD shows the best photodetection properties of blue light at 10 V with a peak responsivity of 149 mA W−1 and EQE of 41.3%, which is almost 20 times higher than those of the control device as well as much higher than the all other reported CsPbBr3 QDs based photoconductor. Finally, the flexibility and long-term operational and environmental stability tests prove the excellent stability of CsPbBr3 QDs-based PD.
The sizes and distribution of QDs were analyzed by TEM as shown in Fig. 1a. It was found that the shape of QDs reveals no obvious changes before and after modification, showing a monodisperse cubic shape. However, we observed that the size of the pristine CsPbBr3 QDs slightly decreases upon introduction of PEA or TCA ligands (Fig. S1 and Table S1†). Next, XRD measurements were conducted to evaluate the effect of used ligands on the crystal structure of precipitated QDs. As shown in Fig. 1b, all samples prepared by drop-casting of QDs on the glass substrates exhibit similar peaks corresponding to (100), (110), (200), (210), (211) and (220) diffraction planes, which indicate a retention of cubic perovskite crystal structure.43 In addition, the diffraction peak at ∼37.7° corresponds to the (211) crystal plane of the perovskite structure did not show any significant shift, and has almost the same full width at half maxima (FWHM) value after the ligand exchange with PEA and TCA, which confirms that the crystal structure of CsPbBr3 QDs remained unchanged (Fig. S2†). The synthesized CsPbBr3 QD solutions possess strong green emission, as presented in Fig. S3.† Fig. S4† demonstrates the PL spectra of the obtained QDs in hexane solution, indicating the narrow emission peak with the maximum located at 516 nm for the reference sample, and 513 and 515 nm for the PEA- and TCA-treated CsPbBr3 QDs, respectively.
The used organic ligands could also affect the band energy structure of the QD samples, which was investigated by ultraviolet-visible (UV-vis) absorption spectroscopy and ultraviolet photoelectron spectroscopy (UPS). UV-vis absorption spectra collected for the reference and modified QDs exhibit almost similar onsets at ∼504 nm (Fig. S5†). The optical band gap calculated by Tauc plot for the reference sample shows a value 2.33 eV, which is consistent with the literature.42 In turn, band gaps for PEA- and TCA-treated CsPbBr3 QDs slightly increases to 2.34 eV. The analysis of UPS results for the reference CsPbBr3 QD film provides a valence band maximum (VBM) of −5.78 eV (Fig. 1c). In turn, the VBM of the TCA and PEA-modified CsPbBr3 QD film is estimated to be equal to −5.61 and −5.58 eV, respectively. As shown in Fig. 1d, the VBM of PEA modified CsPbBr3 QD sample shows a more favourable band alignment match with the work function of Pt metal electrode, which should facilitate easier hole extraction under illumination and consequently enhance the device performance.
The presence and type of the binding motifs of capping ligands with the perovskite were analyzed by 1H nuclear magnetic resonance (NMR). For the calculation of the ratio between capping ligands, see Fig. S6–S8 and ESI Note 1.† In 1H NOESY NMR spectra of all the QD samples the signals of groups bonded to nitrogen atom of DDABr reveal cross-peaks to the neighbouring CH2 groups whose phase is the same as the phase of NOESY diagonal (Fig. S9–S11†). This means that the longitudinal dipole–dipole relaxation between these groups is in the regime where the zero-quantum relaxation prevails over the double-quantum one. This happens when ωτc ≫ 1, where ω is Larmor frequency and τc is the rotational correlation time of the molecule. In our case of Larmor frequency of 500 MHz, the correlation time must then be much larger than 3−10 s. For a small molecule of weight about 400 g mol−1 such a slow reorientation may in non-viscous solvent only occur when it is attached to larger object. Therefore, it is likely that in the case of all QDs, the DDABr molecules strongly interact with the QDs, possibly substituting Cs sites on the surface.44 In the 1H NOESY spectrum of control CsPbBr3 QDs, in the region where the cross-peaks between CH3 and CH2 groups appear, there is only one cross-peak whose phase is the same as NOESY diagonal. It is obviously related to the slowly tumbling DDABr molecules immobilized on the QD surface. The other cross-peaks between strongly overlapping CH2 and CH3 groups are of opposite phase. This suggests that the OA molecules are in the fast reorientation regime, i.e. they are not attached to the QD surface or attached very weakly. The picture is similar in the TCA-treated CsPbBr3 QDs where DDABr seems to be attached to the QD surface, while OA is not. The resonances of TCA do not reveal NOESY cross-peaks, neither to DDABr nor to OA signals, so that it seems that TCA freely tumbles in the solution. Consequently, carboxylate ions do not bind to the QD, but rather neutralize charge on the surface by formation of equilibrium with the DDA ions. In the 1H NMR spectrum of PEA-treated CsPbBr3 QDs all the signals of PEA and the signals of CH2 and CH3 groups neighbouring to the nitrogen atom of DDABr, appear as very broad (half-width-at-half-height ca. 300 Hz at magnetic field of 11.7 T) humps. Since the widths of the latter scale linearly with the induction of the magnetic field, they appear to originate from an amorphous solid phase, and their large widths are due to the distribution of isotropic chemical shifts. In the 1H NOESY spectrum there are cross-peaks of the same phase as diagonal peaks, linking the common broad signal of exchangeable protons (COOH and NH2) at 0.8 ppm, PEA signals, DDABr signals and OA signals. It seems then that the core of PEA-treated CsPbBr3 QDs is covered with the solid phase consisting of DDABr and PEA. The OA, although interacts with the QD surface strongly enough to reveal intense cross-peaks in the NOESY spectrum, shows relatively narrow NMR signals. This suggests that OA is not an ingredient of the amorphous solid constituted by DDABr and PEA on the QD surface but has rotational mobility which allows for efficient chemical shift tensor averaging to the isotropic line.
Since CsPbBr3 QDs have been demonstrated as a promising material for photodetection applications,25,45,46 we sought to investigate how the new ligand shell affects the device performance. Flexible PDs have received increasing attention due to their promising applications in various fields. Here, we used a glass fiber fabric as a flexible and textile substrate for the photodetectors layer system (Fig. S12†). The glass fiber fabric is coated with polytetrafluoroethylene (PTFE) with thicknesses between 70 μm and 250 μm.47 First, we analyze the effect of gold (Au) and platinum (Pt) electrodes on the transient photoresponse of the control CsPbBr3 QDs to select proper metal electrode for deposition.16 The experiments were conducted at a fixed bias of 10 V and under a blue LED (λ = 448 nm) light pulse with irradiance power densities ranging from 0.1 to 50 mW cm−2. The schematic of the studied PD architecture is shown in Fig. 2a. From Fig. 2b, we can observe that the control sample with Pt electrodes generates almost ∼10 times higher photocurrent than the Au-based counterpart, which suggests its superior charge transfer due better Schottky barrier height (SBH) alignment with the CsPbBr3 QDs (Fig. 1d). Therefore, we chose the Pt electrode for further fabrication and characterization of modified CsPbBr3 QDs-based PDs.
Next, we investigate the effect of PEA at various doping concentrations (35, 70, 100 and 150 μL) on the photodetection performance of CsPbBr3 QDs-based PD. Fig. S13† shows TEM images of CsPbBr3 QDs with different concentrations of PEA. As seen, the size of CsPbBr3 QDs decreases with increasing the concentration up to 100 μL (Table S1†). The dark current (Id) is an essential parameter for the characterization of PD. Fig. 2c shows that the reference CsPbBr3 QDs-based device exhibits the lowest Id, which increases with increasing the PEA ligand amount up to 100 μL and drops for PEA = 150 μL but it is still higher than the Id of the reference CsPbBr3 QDs based PD. The enhanced Id upon the addition of PEA could be explained by the improved conductivity of the CsPbBr3 QDs film. The average conductivity of the control and PEA-based CsPbBr3 QDs films is shown in Table S2.† As expected, PEA-modified CsPbBr3 QDs films shows higher conductivity as compared to the control sample likely due to the insertion of the π-conjugation benzene ring and the ligand shortening by partially replacing the insulating ligands with PEA, which helps to improve electronic coupling between the ligands and QDs.48 The reduced conductivity of the CsPbBr3 QDs with 150 μL PEA could be due to the possible formation of an insulating layer created by higher ligand concentration. Further we collected and compared the PD performance for the reference and PEA-modified all CsPbBr3 QDs under blue LED (λ = 448 nm) light irradiation. Typical logarithmic current–voltage (I–V) curves under 50 mW cm−2 blue light irradiance are shown in Fig. 2d. As seen, the photocurrent (Iph) increases with increasing the bias, and the CsPbBr3 QDs with 100 μL PEA exhibits the highest Iph as compared to the other devices. This could be ascribed to the enhanced conductivity and lower amount of traps, which increase the photogenerated charge extraction under external bias. To shed more light on the effect of PEA concentration on the traps and charge generation of CsPbBr3 QDs films, we analyzed their PL and time-resolved PL (TRPL) spectra at room temperature by fitting with a tri-exponential decay function, where the relatively fast (τ1), intermediate (τ2), and slow (τ3) decay components are related to the charge transfer, radiative recombination, and nonradiative recombination of free charge carriers, respectively (Fig. S14 and Table S3†).49 The PL intensity increases with increasing the amount of PEA to 100 μL and drops for film with 150 μL PEA. The average PL lifetime of the CsPbBr3 QDs film with 100 μL PEA equals 20.53 ns, which is longer than that of the control film (16.48 ns). The difference between the average lifetimes for the films with different PEA concentrations is not clearly distinguishable. However, when we combine TRPL and PL data and extracted the comparison of radiative rate, we found that the CsPbBr3 QDs film with 100 μL PEA shows almost four-times higher radiative rate compared to the control film. The higher radiative recombination value in the CsPbBr3 QDs film with 100 μL PEA allows the overall recombination process to be proportionately less dominated by non-radiative recombination processes, which suggest lower surface defect centers in PEA-modified CsPbBr3 QDs films.50 These results indicate the reduction in non-radiative recombination after PEA modification and reconfirmed the presence of lowest defects in the CsPbBr3 QDs film with 100 μL PEA.51
To get more information about the effect of PEA concentration on the recombination and PD performance, we measured the transient photoresponses of all the PDs at 10 V constant bias and under blue light intensity ranging from 0.1 to 50 mW cm−2 (Fig. S15†). Fig. 2e shows the logarithmic plot of Jph as a function of the irradiation intensity under a constant bias of 10 V for all the devices. To reveal the recombination-dependent relationship between the photocurrent and irradiation power, we fitted these results with a power law (Jph ∝ Pβ, where P is the irradiation power and β is the recombination under illumination).18 A nonunity exponent of β (0 < β < 1) indicates existence of complex processes of carrier generation, charge trapping, and charge recombination. However, the β exponent value are significantly less than 1 which suggests the domination of Shockley–Read–Hall recombination (trap-assisted recombination) in our CsPbBr3 QDs-based PD. The maximum value of the β exponent increases to 0.41 for the 100 μL PEA-modified CsPbBr3 QDs-based PD compared to the control device (β = 0.27), which indicates lower recombination and better charge collection under external bias. The parameters of the photodetector performance (responsivity (R), external quantum efficiency (EQE), and specific detectivity (D*)) of the fabricated PDs were calculated using eqn (S1)–(S4),† respectively (see ESI Note 2,†). As expected, PD based on CsPbBr3 QDs with 100 μL PEA exhibits the highest values of R, D* and EQE compared to other devices (Fig. 2f and S16†).
In order to probe ligand-type mediated PD performance, we have compared devices based on CsPbBr3 QDs with 100 μL (0.81 mmol) PEA (L-type) and 120 mg (0.81 mmol) TCA (X-type). As can be seen in Fig. 3a, there is a slight increase in the dark current for the TCA-treated PD compared to the PEA treated device, which can be attributed to the higher conductivity of the TCA-treated CsPbBr3 QDs film (Table S2†). The PL intensity of the TCA-modified CsPbBr3 QDs film is almost 5 times lower than the PL intensity of the PEA treated film (Fig. S17†), which indicates higher non-radiative recombination and higher defects in the TCA-modified film.51 To further analyze the role of surface ligands on the PD performance, we have measured and compared transient photoresponses at a fixed 10 V bias and under a blue LED (λ = 448 nm) light pulse with different irradiance power densities ranging from 0.2 to 50 mW cm−2 (Fig. S18a†). The photocurrent response is almost negligible for the control device, while it improves significantly for TCA- and PEA-treated CsPbBr3 QDs-based PDs reaching a maximum photocurrent for the latter device under low light irradiance (0.2 mW cm−2) (Fig. S18b†). Fig. 3b shows the photocurrent density of the PDs with increasing light irradiance power densities ranging from 0.2 to 50 mW cm−2. We fitted Jphversus incident light intensity with a power law equation (Jph ∝ Pβ, where P is the light intensity and β is the recombination under illumination), which shows a sublinear relationship (Fig. S19†). In general, the power exponent β equals to 1 or very close to 1 indicates the high absorption and conversion efficiency of a high-performance PD. However, a nonunity exponent of β (0 < β < 1) is often found in LHP-based PDs due to the complex processes of charge generation, charge transportation, charge recombination, and charge trapping within the perovskite materials.52 As seen, the value of exponent β decreases from 0.41 ± 0.009 for the PEA-treated CsPbBr3 QDs to 0.37 ± 0.010 for the TCA treatment CsPbBr3 QDs suggesting the existence of higher second-order charge recombination in TCA treatment CsPbBr3 QDs based PDs.
Fig. 3c and d show R and EQE of these devices with a fixed 10 V bias as a function of light power. As seen, the device based on PEA-treated CsPbBr3 QDs exhibits the highest values of R and EQE. The maximum R and EQE reach up to 0.149 A W−1 and 41.3% for PEA-treated CsPbBr3 QDs-based PD compared to 0.051 A W−1 and 14.3% for the TCA-treated CsPbBr3 QDs based PD under low irradiation of blue light (0.1 mW cm−2). In addition, PEA-treated CsPbBr3 QDs-based PD shows almost 3 times higher D* (Fig. 3e) and an on/off ratio (Fig. 3f) than the TCA-treated CsPbBr3 QDs-based PD, and almost 23 times higher Jph than the control PD (Fig. 3b), which highlight its superior charge transfer and performance. Next, temperature-dependent photoluminescence (PL) spectroscopy was applied to determine the exciton behavior of CsPbBr3 QDs-based films. As seen in Fig. S20,† modification of the shell with PEA and TCA increases the exciton binding energy of the CsPbBr3 QDs, which suggests enhanced stability and absorption efficiency. On the other hand, the higher exciton binding energy can affect the charge extraction, which may affect the device's sensitivity.
Therefore, the moderate exciton binding energy of PEA-treated CsPbBr3 QDs film with lower non-radiative recombination and defects helps to improve the device sensitivity. In turn, the highest exciton binding energy observed for the TCA-treated CsPbBr3 QDs film with higher non-radiative recombination and defects limits its performance as compared to the PEA-treated CsPbBr3 QDs film. Table 1 summarizes the performance parameters of our PDs and other previously reported photoconductor-type PDs based on CsPbBr3 QDs.
Device | λ exc | Bias (V) | R (A/W) | D* (Jones) | EQE (%) | On/off | Reference |
---|---|---|---|---|---|---|---|
Au/CsPbBr3/Au | 405 | −3 | 7 × 10−4 | 3.4 × 109 | 0.28 | 5 | 53 |
Au/CsPbBr3-MPA (mp-TiO2)/Au | 405 | 2 | 20 | 8.9 × 1013 | 1 × 105 | 54 | |
Au/CsPbBr3 QD/Au | 504 | 10 | 1.9 | 1.3 × 1012 | 3094 | 55 | |
Pt/CsPbBr3 QD/Pt | 448 | 10 | 8.83 × 10−3 | 1.4 × 1011 | 2.45 | 7.52 | This work |
Pt/CsPbBr3 QD-PEA/Pt | 149 × 10−3 | 9.7 × 10 11 | 41.31 | 34.35 | |||
Pt/CsPbBr3 QD-TCA/Pt | 51.79 × 10−3 | 3 × 1011 | 14.34 | 13.90 |
Finally, the PEA-treated CsPbBr3 QDs-based PD was tested by collecting photodetection data (under fixed 10 V bias and 0.2 mW cm−2 blue light pulse) at various bending angles and multiple cycles of bending. A custom-built setup (Fig. S21†) was used to bend the device, and photodetection data was measured during the bending of the device at every 5° angle, from 0° to 35°. The results, depicted in Fig. 4a, show that the photocurrent increases slightly with increasing the bending angle from 0 to 15° as the distance between the source and the device decreases, leading to an increase in luminescence intensity. After 15°, the photocurrent decreases as expected due to the strong bending of the PD, whereby the increasing light hits the surface at a very flat angle and is increasingly reflected there. Furthermore, the durability of the PD was measured against the bending cycles. As seen in Fig. 4b, the device has retained ∼96% of its performance after a 150 bending cycle. These results reveal that both the fabric substrate and the CsPbBr3 QDs-films are durable for after 150 bending cycles and long-time flexible operations. Besides the mechanical bending stability, long-term operational and environmental stability is also measured. The functional stability of unencapsulated PEA-treated CsPbBr3 QDs-based PD was measured under ambient conditions (Relative humidity = 30%, 25 °C) at 10 V bias and continuous 5 mW cm−2 blue light pulse. As shown in Fig. 4c, the output of this PD maintained 90% of its initial performance after 10 hours of continuous operation. Next, the unencapsulated PD was kept for 2 weeks under dark condition in ambient condition (Fig. 4d). Notably, the device still maintains 93.8% of its initial performance confirming noticeable operational stability. We also tracked and compared the long-term shelf life stability of the reference and PEA-treated CsPbBr3 QDs-based PDs without any encapsulation under 30–40% relative humidity at room temperature. It was observed that these conditions were detrimental for the device stability, likely due to ligand detachment from the QD surface upon aging.27 The PEA-treated CsPbBr3 QDs-based PD maintained only ∼14% of its initial efficiency after aging for 4 months (Fig. S22†), while the reference device completely decomposed, showing no response under similar conditions. Our works on developing encapsulation protocol and further rational compositional engineering of QD shell, which would allow to achieve stable and durable devices, are in progress.
Photoluminescence spectra at room temperature are taken using a Shimadzu RF-6000 spectrometer and the room-temperature TRPL data were collected using the sub-nanosecond (75 ps FWHM) pulsed diode laser with central emission wavelength 405 nm from Hamamatsu – laser – head M8903-01 and driver – picosecond light pulser C8898. The pulse repetition rate was set to 100 kHz (10 μs). For the detection we used the Andor SR-500i monochromator with diffraction grating 600/500 nm and Peltier cooled charge-coupled device (CCD) camera of Andor DV420-FI. After acquiring the PL spectrum, the central detection wavelength was tuned to the PL maximum peak, and the detection was switched from CCD camera to single photon avalanche photodiode SPAD – model SPCM-AQR-13 from Excelitas Technologies. The sync and the SPAD signals were registered using a picosecond event timer – model PicoQuant HydraHarp 400. The excitation laser light and detection PL signal were aligned in confocal setup via Nikon L Plan achromatic objective with ×100 magnification and 0.7 numerical aperture (NA).
The TRPL decay is fitted using a tri-exponential decay using the following formula;
The average lifetimes are calculated using the intensity average formula;
HOMO = 21.22 − (Ecutoff − Eonset) |
LUMO = HOMO + Bandgap |
Footnote |
† Electronic supplementary information (ESI) available. See DOI: https://doi.org/10.1039/d5ta00046g |
This journal is © The Royal Society of Chemistry 2025 |