Nathalie K.
Fernando
a,
Claire A.
Murray
b,
Amber L.
Thompson
c,
Katherine
Milton
a,
Andrew B.
Cairns
d and
Anna
Regoutz‡
*a
aDepartment of Chemistry, University College London, 20 Gordon Street, London, WC1H 0AJ, UK. E-mail: regoutz@chem.ox.ac.uk
bDiamond Light Source Ltd, Diamond House, Harwell Science and Innovation Campus, Didcot, Oxfordshire OX11 0DE, UK
cChemical Crystallography, Chemistry Research Laboratory, University of Oxford, South Parks Road, Oxford, OX1 3QR, UK
dDepartment of Materials, Imperial College London, Royal School of Mines, Exhibition Road, SW7 2AZ, UK
First published on 9th April 2025
With the advent of ever more intense and focused X-ray sources, including in laboratories, at synchrotrons, and at X-ray free electron lasers, radiation-induced sample change and damage are becoming increasingly challenging. Therefore, the exploration of possible mitigation strategies is crucial to continue to allow the collection of robust and repeatable data. One mitigation approach is the introduction of short, X-ray-free “dark” periods. However, it is unclear whether this strategy minimises damage or, in actuality, promotes it through a phenomenon called “dark progression”, i.e. the increase or progression of radiation damage that occurs after the X-ray beam is turned off. This work discusses the influence of introducing dark periods and their duration on the radiation-induced changes in two model small-molecule catalysts, [Ir(COD)Cl]2 and [Rh(COD)Cl]2, exposed to X-ray radiation in synchrotron powder diffraction (PXRD) and laboratory photoelectron spectroscopy (XPS) experiments. This provides, for the first time, insights into how damage progresses under varying radiation regimes and allows the distinction between the processes that affect the unit cell itself, the individual molecular units, and the respective atomic chemical environments. Furthermore, it provides the basis for informed decision-making in the design of future experiments where the need to minimise radiation-induced damage is crucial.
In MX, strategies to prevent radiation damage are increasingly finding their place in experiments involving radiation-sensitive samples, in large part due to comprehensive studies conducted over the years by Garman et al., Owen, de la Mora, Weik, Warkentin, and others, to name but a few.2–7 These key X-ray damage mitigation strategies can be found summarised in the review by Shelley et al.8 and include cryocooling in nitrogen below 110 K, ensuring radiation dose is adequately quantified (by implementing tools such as RADDOSE-3D), the use of higher incident X-rays, or in cases of heavy element materials, back-soaking crystals in a buffer containing lighter elements to ensure sample stability before irradiation. Another common mitigation strategy in macromolecular applications is the aforementioned “diffraction before destruction” method comprising of the use of multiple crystals to complete a data set. Such methods are certainly not commonplace in small molecule X-ray experiments and further work is required to develop a similar set of radiation damage mitigation strategies for such samples.
The increase or progression of radiation damage that occurs after the X-ray beam is turned off is often termed “dark progression”. The handful of studies that exist on this topic, and which will be discussed below, investigated dark progression to probe damage timescales and determine a potential dose-rate dependence of global radiation damage, as well as the possibility of outrunning it. Despite these reports, there remains a noticeable gap in understanding dark progression in small molecule systems, which are typically subject to direct X-ray exposure without a parent solvent, in contrast to protein crystallography. The aim of this study is to thus bridge this knowledge gap and determine the influence of dark periods on radiation damage effects in these metal complexes.
It is first important to revisit briefly the timescales of radiation-induced processes. It is well-understood that primary X-ray photon–electron interactions occur on timescales of femtoseconds. These interactions often result in the formation of photoelectrons, which in turn interact with atoms comprising the sample and produce free radicals, which are known to occur on sub-picosecond timescales. In addition to the photoelectric effect, primary damage can also occur in the form of Auger-Meitner decay, more prominent in soft X-ray interactions, and Compton scattering. These phenomena can trigger the cascade of secondary electrons which further contributes to sample damage. Photoelectron–electron (matter) interactions also occur on femtosecond timescales. These excitations initiated by the X-ray photon thermally diffuse, resulting in global sample damage. The rate at which thermal diffusion occurs is very much temperature-dependent, slowing at lower temperatures. Most small-molecule X-ray experiments are conducted at room temperature, where the diffusion rate is high, potentially leading to bond damage. This can lead to further excitation reactions of even longer duration.
Anecdotal evidence of the degradation of protein crystals at room temperature after being removed from an X-ray beam was first reported by Blundell and Johnson in 1976.9 Subsequent investigations into this phenomenon have not always been able to corroborate these findings, fueling greater uncertainty. At cryotemperatures (T = 100 K), Ravelli and McSweeney found no conclusive evidence of dark progression with respect to the global metrics, mosaicity and B-factors, an indicator of crystal disorder and atomic fluctuation, respectively.10 However, the authors noted an increase in the site-specific Rmerge value, used to describe the agreement between multiple measurements of a given reflection (to determine data quality), during X-ray-free periods of 10 min and 19 hours. Work by Kmetko and Southworth-Davies also showed no evidence of dark progression at T = 100 K and T = 300 K, using global damage metrics.11,12 Beyond typical global damage metrics, using a UV/Vis microspectrophotometer device inline during XRD experiments, McGeehan et al. noted a drop in optical density of proteins during X-ray-free dark periods, signalling the site-specific decay of disulfide radicals and trapped electron content at temperatures of 100, 130 and 160 K.13
By the early 2000s, no concrete evidence of dark progression of global damage had been established at either T = 100 K or T = 300 K. The focus then shifted to exploring dose rate as a possible contributing factor to dark progression. For instance, Warkentin et al. studied dark progression in thaumatin crystals by conducting impulse-response measurements at different dose rates.14 The increase in B-factors, measured straight after dark intervals (of 240 and 660 s), determined the extent of dark progression. Contrary to earlier reports, dark progression was observed on timescales from 200 to 1200 s between temperatures of T = 180 K and T = 240 K. For instance, a 27% reduction in global damage at T = 240 K was reported in datasets collected in 600 s, compared to those collected during 1200 s long measurements, suggesting a reduction in damage with increasing dose rate. However, no dark progression was observed from T = 25 K to T = 180 K. The authors also found that longer dark intervals result in greater global damage. This study showed the potential for outrunning some global radiation damage at temperatures above T = 180 K by combining several factors, such as faster data collection and moderate cooling.
The authors noted that the shortest damage timescale that can be determined experimentally is limited by the duration of the probe pulse, which is defined by the time it takes to obtain a diffraction pattern of high enough resolution to assess the damage. If the timescales for damage processes are significantly longer than the experimental time or much shorter than the probe pulse, no dark progression will be measured. In a follow-up study, they tested a wider range of dose rates. They noted that the dose-rate effect of radiation damage is too small to be noticeable at T = 300 K.15 Thus suggesting that at T = 300 K, radiation damage processes occur faster than the approximately 1–10 s minimum data collection time. Warkentin et al. also hypothesised that adding X-ray-free pauses during measurement contributed to the inverse dose-rate effect observed via relaxation processes.
In the same year, Owen et al. studied the room temperature X-ray-induced decay of protein and virus crystals as a function of dose rate with faster readout detectors and short X-ray exposure times using the full flux of an undulator beamline at Diamond Light Source.16 Two detector-readout modes were compared to determine whether continuous diffraction data collection (without repeated pauses in X-ray irradiation while the detector reads out) results in increased crystal lifetimes. The authors showed that crystal lifetime was reduced by a factor of two when there was a pause between frames within a dataset. This is in contrast to the findings in the 2012 study by Warkentin et al.15
It has been reported previously that very short femtosecond XFEL pulses deposit a massive X-ray dose, leading to indexable diffraction from crystals at RT before the complete ionisation of the structure destroys it in less than 100 fs.17,18 Based on these observations, Owen et al. suggested three sources for radiation damage in macromolecules at RT and their significance at slow and fast timescales. On slow timescales (>1 s), radical diffusion (and quenching within the solvent) occur, while on fast timescales (<60 ms), radical diffusion, quenching, and recombination are all relevant. Based on these findings, Owen et al. suggest that more intense beams and faster detectors might make RT data collection more appealing for MX studies.
The progression of damage during dark periods can be attributed to the timescales of diffusion and the reaction of free radicals, as well as diffusive conformational motions of the structure. Dark progression is also attributed to the mobility of molecular hydrogen gas, which is generated by the X-ray interaction with the sample and subsequently trapped within the crystal. Meents et al. attribute the temperature dependence of radiation damage at low temperatures in protein crystals to the temperature dependence of hydrogen gas diffusion.19 Hydrogen gas produced inside the crystal can perturb the steady state by creating pressure, which can be released or redistributed within the crystal. This may be a source of the radiation-induced bond-breaking and creation of defects in crystals. Local atomic displacements and electronic rearrangements create further pressures, leading to lattice expansion. Protein crystals typically comprise mostly of hydrogen atoms, and therefore, it is expected that a significant fraction of broken bonds will result in the release of hydrogen. Therefore, hydrogen contributes to the internal pressure of the crystal and consequently global radiation damage, particularly at room temperature, where molecular hydrogen is highly mobile. As expected, hydrogen mobility does not contribute to diffraction damage effects at cryotemperatures.
Unlike the previous studies of biological macromolecular crystals outlined above, here, the possible occurrence of dark progression at RT, as noted by Owen et al., is investigated in model small-molecule systems, namely [Ir(COD)Cl]2 and [Rh(COD)Cl]2, where COD = 1,5-cyclooctadiene. This is achieved by probing global (XRD) and specific (XPS) changes. The authors' previous systematic damage study on these systems over sustained periods of X-ray exposure using these methods found clear loss in crystallinity and movement of the central M–Cl structure with increasing X-ray exposure, whilst XPS showed a notable photoreduction of the metal as well as the loss of Cl.20 In this paper, we investigate whether the extent of these sample changes are impacted by introducing dark periods during the measurement timescales. The influence of the duration of the dark period in PXRD experiments on the extent of global damage is also explored.
For the PXRD experiments at beamline I11, Diamond Light Source, UK [Ir(COD)Cl]2 and [Rh(COD)Cl]2 were mounted into 0.3 mm borosilicate capillaries. The PXRD study can be separated into two components, the first being a comparison of incorporating a light (X-ray beam on) period and a dark (X-ray beam off) period of the same duration, represented in Fig. 1.
In the first instance, the standard experimental protocols used at beamline I11 were followed, namely a 2 s data collection time, followed by 3 s of irradiation, and finally 9 s of detector read-out/data saving time, during which time the X-ray shutter was in, and the sample was no longer irradiated. This irradiation regime corresponds to an irradiation:
dark time ratio of 1
:
1.8 per pulse (approximated to 1
:
2 in this paper). This process was repeated in iterations such that 500 diffraction patterns were collected in total (over 2 hours). As in,21 0.3 mm borosilicate capillaries were used with a photon energy of 15 keV throughout at T = 300 K. A second data set was collected in the same way, except for the 3 s irradiation time being replaced with 3 s of X-ray-free, dark time to determine the impact of incorporating an X-ray-free element into data collection. This regime corresponds to an irradiation
:
dark time ratio of 1
:
6 per pulse.
The second part of the PXRD study aimed to determine the effect of the duration of this dark period on global structure. To compare gap durations, the dark period between the 2 s data collection and 9 s detector read-out/data saving time was increased from 3 s to 12 s dark period corresponding to a 1:
10.5 irradiated
:
dark ratio, which is approximated to 1
:
10 throughout the paper. Again, these diffraction patterns were collected iteratively so that 500 total scans were obtained at the end of the experiment. A combination of batch Le Bail and Rietveld PXRD refinements was carried out on this data using the TOPAS Academic v7 software package.22,23 In order to determine changes to the individual lattice parameters and overall unit cell volume over the measurement period.24 For batch Rietveld refinements,25 starting atomic coordinates were taken from results of the single crystal XRD structure solution conducted by Fernando et al.20 M–Cl and C–C distance restraints were applied to achieve a reasonable starting structure and were maintained for the rest of the dataset.
For ease of comparison across the structures corresponding to each irradiation regime during structural refinements, a rigid-body approach to describe the cyclooctadiene (COD) ligands was used, as first introduced in ref. 21.
To facilitate the comparison of damage of both the Ir and Rh catalyst at the different light/dark ratios, X-ray dose was estimated using the RADDOSE-3D tool.26,27 As with the dose estimations carried out in Fernando et al. 2021 and Fernando et al. 2022,20,21 the small molecule crystal addition to the programme, introduced by Christensen et al., was used, along with the capillary model introduced by Brooks-Bartlett et al.28,29 The beam parameters, including spot size and FWHM, were obtained from the characterisation of the I11 beamline undertaken by Thompson et al. in 2009 at 15 keV with a photon flux of 1.5 × 1014 ph s−1, see Fig. 2(a) and (b) in ref.30 and are captured in Table S1 of the ESI.† To complement PXRD findings on global changes, XPS experiments on the Thermo Scientific K-Alpha+ instrument at Imperial College London, UK, were conducted to determine the effect of introducing dark periods on specific changes. The spectrometer contains a microfocused monochromated Al Kα X-ray source (hν = 1.487 keV), with a 180° double focusing hemispherical analyser and 128 channel detector. The spectrometer operates with a 6 mA X-ray anode emission current and 12 kV accelerating voltage and has a spot size of 400 μm. The energy resolution of the spectrometer was determined to be 0.44 eV. The photon flux at these experimental parameters is calculated to be approximately 3.8 × 1010 photons s−1 from source parameters obtained from the manufacturers. The base pressure of the spectrometer was 2 × 10−9 mbar.
As a control dataset, each sample, mounted on adhesive carbon tape, was irradiated continuously for a total of 13 hours, with core level (CL) and valence band (VB) spectra being collected iteratively every 2 hours. For the dark measurement, on a fresh sample, two scans of each CL and VB (totalling approximately 3 min) were collected. The X-ray beam position was then moved away from the irradiated spot on the sample for 1 min (in reality, including data saving and sample height alignment, this was 1 min 50 s.) The above steps comprised a single iteration. 50 iterations were measured to obtain comparable spectral resolution to the continuous dataset. These 50 iterations comprised a single group and were repeated eight times, with the total X-ray irradiation time per group being approximately 2 hours. XPS peak fit analysis was carried out using the ThermoScientific Avantage software package, following the method outlined in Fernando et al.20 The peak fitting functionality was used, with the in-built Smart background, a development of the Shirley background.31 The average published spin–orbit splittings of Ir, Rh, and Cl from the NIST X-ray Photoelectron Spectroscopy database informed the constraints applied on the peak positions.32 The FWHM parameter and Lorentzian/Gaussian ratios of the Voigt function used to fit the peaks were refined, and the areas of each spin–orbit peak were constrained according to their Scofield photoionisation cross sections.33,34
Following on from the first application of RADDOSE-3D in XPS studies, presented in Fernando et al. 2021, the tool was again used to estimate dose over the long course of X-ray exposure during the XPS experiments outlined here. Dose is estimated using the AD-WC (Absorbed Dose - Whole Crystal) metric, defined as the total energy absorbed divided by the mass of the whole crystal. This metric is chosen since the FWHM of the X-ray beam is such that the entirety of individual crystals is irradiated by the beam. A tabulated summary of the main input parameters for [Ir(COD)Cl]2, [Rh(COD)Cl]2 used in all RADDOSE-3D calculations are provided in Table S1 in the ESI.† Given each dark:light irradiation regime will have a unique maximum X-ray dose, in order to more effectively compare crystallographic and chemical changes across the regimes, all analysis is carried out on the changes as a function of X-ray dose i.e. normalised to the dose.
By directly comparing the changes to the individual lattice parameters of the Ir complex, both as a function of dose and the three different irradiation regimes outlined above, notable consistencies across all lattice parameters, a, b, c and cell volume can be observed (see Fig. S1 in the ESI† for comparative plots of all four). The 1:
2 regime shows the smallest increase in lattice parameters, followed by 1
:
6 and finally 1
:
10, which shows the greatest increase as a function of dose. For all lattice parameters, the linear expansion between the 1
:
6 (12 s gap) and 1
:
10 (21 s gap) datasets appear to be identical from the onset of irradiation until a cumulative dose of approximately 20 MGy after which point the curves diverge. The difference in the onset of curve plateauing is also evident, with the 1
:
2 dataset plateauing later than the two longer dark-duration datasets. Results from Le Bail refinements suggest that there is a clear dependence of unit cell expansion, on the X-ray irradiation regime chosen. A longer proportion of X-ray irradiation relative to dark time is clearly more favourable in these experimental timescales, in which long-scale diffusion processes dominate. Conversely, in XFELs, for instance, the effects of even very short-scale damage processes are limited.15 This suggests that reducing the light-to-dark ratio enables long-range damage processes to dark progress further through the crystal. In other words, reducing the duration of the X-ray-free period means the time between measurements is shorter, and as such, only a fraction of the dark progression of long-range damage is observed in the subsequent diffraction pattern.
In order to quantify the point at which the unit cell volume of the Ir complex begins to reach saturation, the onset of the plateau observed from the above Le Bail refinements is determined from the first and second derivative curves of volume as a function of X-ray dose, see Fig. S2 in the ESI.† From this, it is then possible to determine whether a certain X-ray irradiation/dark regime promotes the crystal to reach maximum volume earlier with respect to the others for the same cumulative absorbed dose.
By definition, the region defined by the point at which the linear region diverges, signals the onset of the plateau to the point at which it begins to stabilise in the first derivative curve. The point of inflexion of this change can be seen in the second derivative curve, which is used to define the point of plateau. The first derivative curve for all three irradiation-dark regimes, see Fig. S2(b) in the ESI,† can be separated into three main regions. There is an initially flat (or subtle upwards incline) from the onset of irradiation up to a certain dose. This dose is 31 MGy, 11 MGy and 17 MGy, for the 1:
2, 1
:
6 and 1
:
10 datasets, respectively. After this critical dose is reached, there is a significant downward slope, signalling the plateau region, stabilising at a later cumulative dose. This dose is 221 MGy and 100 MGy for 1
:
2 and 1
:
6, respectively. The 1
:
10 first derivative of volume is too subtle to notice the point at which the curve flattens, meaning that the plateau has not yet stabilised in the timeframe of the experiment.
Considering both Fig. S2(b) and (c) in the ESI,† the point of plateau onset and the mid-point are almost the same for both 1:
6 and 1
:
10 datasets, the difference between which could be considered insignificant. However, for the 1
:
2 dataset, with the largest irradiated-to-dark duration ratio, the plateau region occurs at a much higher dose, meaning that the unit cell volume increase reaches saturation at a similar point regardless of the duration of the dark period. In other words, the difference between the longer-duration dark X-ray regimes and the light 1
:
2 regime is stark. This potentially suggests that the long-range damage time scales roughly correspond to the 1
:
6 dark duration (3 s dark gap + 9 s dark data saving time) such that the dark progression reaches its maximum in the 12 s when the X-ray shutter is on. At the 1
:
2 regime, it is hypothesised that the diffraction pattern collection times are so frequent that it is too early in the long-range damage process with respect to the other two regimes.
The same approach of Le Bail refinements was carried out on the equivalent monoclinic [Rh(COD)Cl]2 datasets to determine changes to lattice parameters a, b, c, β and volume, see Fig. 3. As with the Ir complex, the Rh complex shows the same order of lattice parameter increase across the three different regimes (a ≪ b< c). As reported in ref. 20, the overall changes are almost an order of magnitude smaller with respect to the unit cell changes observed in the Ir complex. At 35 MGy, the unit cell volume expands by approximately 0.4%, 0.7% and 0.6% for the 1:
2, 1
:
6 and 1
:
10 setups, respectively. Despite these very subtle changes, comparing first the light vs. dark cases, it is clear to see that in the 1
:
2 light-to-dark regime, the rate of increase across all refined lattice parameters, is lower than the ‘darker’ 1
:
6 regime. The changes are particularly small in the 1
:
2 case as evidenced in Fig. 3(a), by the periodic discontinuities in the linear trend which can be attributed to the electron top-up of the synchrotron storage ring. These become more visible relative to the extracted values as the order of magnitude of the changes to the diffraction pattern is close in magnitude to the changes induced by the top-up discontinuities. However, unlike in the Ir complex, the lattice parameter increases do not appear to have reached a plateau at the final cumulative dose corresponding to the end of the experiment—in other words, a linear increase is observed throughout. Considering the effect of dark gap duration across all lattice parameters, the 1
:
6 (12 s gap) case increases at a greater rate than the 1
:
10 (21 s gap) case, although, quantitatively, the margins by which they differ are minimal.
As in the Ir complex case, to better compare differences across the three measurement regimes, each lattice parameter was plotted separately as a function of X-ray dose and irradiation-gap regime, see Fig. S3 in the ESI.† Comparing first the 1:
2 against the 1
:
6 regime, it is clear that all refined lattice parameters of the 1
:
2 increase at a notably lower rate than those of the 1
:
6, and as such, it appears to be the more favourable of the settings to limit radiation-induced structural damage. This is consistent with the findings of the lattice parameter increases of the [Ir(COD)Cl]2. Next, comparing the 1
:
6 against the 1
:
10 data to determine the effects of gap duration, the 1
:
10 dataset is seen to increase at a lower rate than 1
:
6. This is in contrast to the findings of the Ir complex; however, comparing percentage increases, it is clear that the differences are very small. Therefore, in an experiment, there is no real motivation to use one over the other. This observation of the changes to the Rh complex unit cell again demonstrates that the long-range damage timescales reach a maximum close to or shortly after the 1
:
6 X-ray free gap of 12 s (3 s + 9 s data saving), and as such, increasing the gap duration to 21 s (12 s + 9 s data saving) will make very little difference to the overall structural damage. In the 1
:
2 case, however, the diffraction patterns probe early in the radical diffusion lifetime.
Considering first the percentage changes to lattice parameters for both complexes, Fig. 4(a) and (d), obtained from the Rietveld refinements, it is evident that the trends in lattice parameters increase across the three irradiation regimes, agree with those obtained from Le Bail refinements. Correlating the changes to bond angles and interatomic distances extracted from the structure files initially for the Ir complex, Fig. 4(b) and (c), the Cl–Ir–Cl angles increase while the Ir–Cl–Ir overall a experience decrease in bond angle to a lesser extent (although at 1:
6 this is seen to increase very slightly but lies within the margins of error). Trends in interatomic distances are more subtle, however, the Cl–Cl distance undergoes a substantial expansion relative to the other atomic pairs, which is particularly pronounced in the 1
:
6 case (+7.2%). This consistent Cl–Cl expansion is in agreement with the results previously reported by the authors of this work,20 wherein the motility of Cl atoms within the M–Cl core was attributed to the loss of Cl observed in XPS. The initial (minimum XRD dose) interatomic distances and bond angles and the corresponding values at a dose of 89 MGy and 35 MGy for the Ir and Rh complex, respectively, are captured in Tables S2 and S3 in the ESI.† In the 1
:
2 case, the Cl1 swings back from its initial bent structure about the Ir–Ir axis and extends slightly out relative to the M–Cl core. This explains the increase in Cl–Ir–Cl angle observed (+3%) and the very slight increase in Cl1–Cl2 (+1.8%) due to the Cl1 pushing away from the central M–Cl structure. For the 1
:
6 structure at 89 MGy, the Cl2 atom, instead of the Cl1 atom, is found to swing back drastically about the Ir–Ir axis such that there is a flattening of the central M–Cl about the M–M axis. Increasing the duration of the gap to 12 s sees the Cl–Ir–Cl angle increase about the M–M axis by approximately 5%. This widening of the central motif about the M–M axis agrees with the previous characterisation of PXRD radiation damage in the Ir complex.20 The order of Cl–Ir–Cl angle increase from smallest to largest is 1
:
2, followed by 1
:
10, then 1
:
6. From Le Bail refinements, it is expected that 1
:
6 has a smaller angular increase than the 1
:
10 structure. There is no significant difference between Ir–Cl distances across the three irradiation regimes. Overall, Rietveld refinements show consistently that the M–Cl rhombus flattens predominantly about the Ir–Ir axis. This is mainly attributed to the movement of Cl atoms (either Cl1 or Cl2). The Ir atoms move slightly, but the overall change in the central part of the molecular unit is dominated by the movement of Cl atoms. These changes to atomic coordinates of the M–Cl core can be seen in Fig. 5, which presents a heat map of the atomic displacement magnitudes of the 89 MGy structure relative to the initial, minimum dose structure.
![]() | ||
Fig. 5 The magnitude of atomic displacements, in Å, of the central M–Cl core of the [Ir(COD)Cl]2 unit cell after an absorbed dose of 89 MGy, relative to the minimum dose structure for the three regimes of X-ray irradiation to X-ray-free ratios of (a) 1![]() ![]() ![]() ![]() ![]() ![]() |
In the case of [Rh(COD)Cl]2, all atomic displacements are too subtle to observe visually (see Fig. S4 in the ESI†). However, the quantitative data extracted from the Rietveld refinement, see Fig. 4(e) and (f), show a reduction in Cl–Cl distances for all irradiation regimes and an increase in Rh–Rh distances (opposite to Ir complex), as was observed in the authors' previous work.21 There is a marginal increase in Rh–Cl–Rh angle with a marginal decrease in Cl–Rh–Cl angle. The small changes to atomic coordinates of the Rh–Cl core are evident in the heat map of atomic displacement magnitudes of the 35 MGy structure relative to the initial, minimum dose structure. Results of the Rietveld refinement for the Rh complex show agreement with the Le Bail refinements in the trend that 1:
6 undergoes the greatest structural change; however, the extent of these changes is minimal, and no definitive conclusions can be drawn.
To summarise, moving from the 1:
2 irradiation regime, where a 3 s wait X-ray-on period follows a diffraction pattern collection, to the 1
:
6 regime, where the 3 s wait period is dark, systematic structural differences are observed. These are evidenced by a systematic increase in lattice parameters, Cl–M–Cl bonds, as well as an expansion of the Cl–Cl bond. Thus, the impact of reducing the light
:
dark ratio from 1
:
2 to 1
:
6 on the dark progression of long-scale damage is clear. The long-range cascade of radicals appears to continue past the timescales of the 1
:
2 data collection. It is interesting to note that increasing the duration of the dark time from 12 s (1
:
6) to 21 s (1
:
10), sees a drop in Cl–M–Cl bond and Cl–Cl increase. This is despite all lattice parameters continuing to increase.
Previous UHV XPS experiments showed that the molecular unit undergoes substantial local loss in Cl from the onset of irradiation, even at relatively low X-ray doses.20 A potential explanation for the behaviour observed in the present PXRD results could be that Cl loss continues to occur during the dark period. The local cleaving of the Cl–M bonds and the formation of Cl species outside the main molecular unit, could mean that of the eight molecular units in the Ir complex and four in the Rh complex, after 21 s of X-ray free time, there are some molecules which are deficient of a Cl atom and others which are not. As such, the averaged atomic positions extracted from Rietveld refinements may no longer be robust enough to describe reliably the M–Cl coordination. An explanation of why this is not observed in the 1:
6 dataset, despite also losing Cl atoms, could be that there is a threshold after which the majority of the Cl atoms in the irradiated sample are lost, and therefore the information obtained from Rietveld refinements no longer describes the majority of molecular units. However at 1
:
6, despite some loss in Cl, the majority of Cl atoms could still be bound to the metal atoms.
In addition, temperature effects can also play a role. The temperature change of the sample owing to the X-ray beam may peak before it gradually dissipates and cools, in the absence of further irradiation during the dark period. It is, therefore, expected that the sample temperature after 12 s (1:
6) of dark time is greater than after a 21 s gap. As such, long-range heat dissipation (and sample temperature) may play a greater role than photoionisation effects in dark periods, suggesting that the atomic coordinate and bond differences between the 1
:
6 and 1
:
10 datasets could be due to thermal atomic vibrations. However, crucially, this temperature hypothesis does not explain why the 1
:
2 regime experiences smaller structural change relative to the 1
:
6 regime, so is highly unlikely to be applicable in this experiment.
For [Ir(COD)Cl]2, the systematic increase in lattice parameters from 1:
2 to 1
:
6 to 1
:
10 irradiation regimes, despite the apparent easing of Cl displacement, can be explained by the overall increase in disorder (thermally-driven or otherwise) and the possible radiation-induced formation and build-up of H2, resulting in growing lattice strain.
These chemical changes are then compared with those observed when the measurement point is irradiated continuously, with spectra collected every two hours. Upon direct visual comparison of the core level spectra of the complexes irradiated continuously, with those obtained with gaps incorporated into the measurement, with respect to the absorbed dose only subtle differences are observed (see Figure S6 in the ESI†). At an approximately equal given dose of 7–8 MGy for the Ir complex, the continuous and gap Ir 4f spectra show no notable difference. The Cl 2p spectra are very similar, although there is a very slight increase in intensity at the lower binding energy component for the gap spectra. At 6–7 MGy, the continuous and gap Rh 3d and Cl 2p spectra of the Rh complex are identical within the accuracy of the experiments.
Quantitative analysis of the spectra further underlines these qualitative observations. Fig. 7(a) shows that in both Ir and Rh complexes, the reduction in the metal centre is comparable across the two irradiation regimes within the experimental errors. Both setups experienced a ≈30% drop of Ir1+ and 20% drop of Rh1+ for the two complexes, respectively. Similarly, the overall loss of Cl relative to the metal which sees a 15% loss under both irradiation regimes, Fig. 7(b) and (f).
The relative changes in the two Cl species present in the samples are also explored, where Cla corresponds to the intrinsic Cl environment and Clb, the formation of a new Cl species, see Fig. 7(c) and (g). In the Ir complex, there is initially no notable difference in Cla/Clb between the irradiation regimes. However, after a dose of 7 MGy, the proportion of Cla in the continuously irradiated sample stabilises whilst, in the gap measurement, the Clb continues to decrease linearly. This divergence at higher dose is likely due to the substantial decrease in Cl 2p resolution as Cl is liberated from the complex, which introduces greater uncertainties in the results of the peak fit. For the Rh complex, see Fig. 7(g), it is evident that there is no difference in Cla/Clb trends when continuously irradiating and introducing X-ray free gaps. The VBM to EF shift (Fig. 7(d) and (h)) again show no notable difference between the irradiation setups. VB spectra show that under the two irradiation regimes, both systems become metallic after approximately 4 and 3–5 MGy dose for Ir and Rh, respectively.
As no notable difference in local chemical change can be observed for both complexes when periodic dark periods are introduced in the XPS measurements, it can be deduced that no dark progression occurs. This observation confirms that timescales of such site-specific events, e.g. metal reduction (which is well understood to be of the femtosecond order) and Cl loss, are very short relative to the irradiation period in this experiment. As such, the local damage processes have essentially finished within the duration of the irradiation pulse, and no further damage occurs in the dark period.
To determine whether site-specific dark damage can be observed in these systems, XPS experiments were conducted, comparing a continuous X-ray irradiation regime with one where short dark periods were incorporated into the measurement. Comparing the local chemical changes between these two regimes showed no significant difference in the extent of sample damage. This indicates that the local photoreduction and loss in Cl are short-lived processes and that these timescales are much shorter than the duration of the probe X-ray pulse (of approximately 3 minutes) so that all possible damage has occurred before the dark period begins. Note the duration of X-ray exposure used in this laboratory XPS experiment is orders of magnitude longer than typical in XFEL pulses, primarily due to the limitations of obtaining high quality XP spectra over short time frames.
These studies confirm the importance of reducing, as much as possible, X-ray-free dark periods during measurements, which in X-ray experiments typically originate from slow detector read-out times to outrun global damage. This is in agreement with the work on protein crystals by Owen et al.16 Stopping exposure to X-rays momentarily does not, as might be expected, relax the system (and reduce damage) as dark progression is shown here to occur even on second timescales during synchrotron experiments.
Crucially, through the systematic light:dark experimental approaches outlined in this work, the occurrence of global dark progression on these model catalysts was confirmed. These results strongly motivate future computational studies— to model the differences in kinetic and chemical processes under continuous and discontinuous irradiation, with varying X-ray-free gaps and shed further light on the damage pathways.
Footnotes |
† Electronic supplementary information (ESI) available. See DOI: https://doi.org/10.1039/d5cp00089k |
‡ Present address: Department of Chemistry, Inorganic Chemistry Laboratory, South Parks Road,OX1 3QR, UK. |
This journal is © the Owner Societies 2025 |