Open Access Article
This Open Access Article is licensed under a Creative Commons Attribution-Non Commercial 3.0 Unported Licence

Uncovering the unusual anodic current during tetrafluoroborate anion deintercalation from a graphite cathode in ethylene carbonate

Haibo Liu ab, Yunju Wang c, Guobao Xu *ab and Hongyu Wang *c
aState Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun 130022, China. E-mail: guobaoxu@ciac.ac.cn
bSchool of Applied Chemistry and Engineering, University of Science and Technology of China, Hefei 230026, China
cKey Laboratory of UV Light Emitting Materials and Technology, Ministry of Education, Northeast Normal University, 5628 Renmin Street, Changchun 130024, China. E-mail: hongyuwang@aliyun.com

Received 13th September 2024 , Accepted 2nd November 2024

First published on 4th November 2024


Abstract

During the deintercalation of ethylene carbonate (EC)-solvated tetrafluoroborate anions (BF4) from a graphite cathode, an unusual anodic counter current was observed. The generation of counter-current is revealed to stem from the interaction between EC and BF4, which provides new clues to the often-overlooked C–H⋯anion weak interactions in dual-ion battery (DIB) or other battery electrolyte research.


Achieving, identifying, and controlling electrochemical ion-solvent cointercalation are of importance in the field of electrochemical energy storage, particularly, in order to enable post-lithium cell chemistries.1,2 In DIBs, anion–graphite intercalation compounds (AGICs) are usually employed as cathode materials. Anions intercalate from electrolyte solutions into graphite electrodes during the charge process, whereas they deintercalate from graphite into electrolyte solutions during the discharge process, corresponding to the anodic and cathodic currents, respectively.3–5 However, in the case of BF4 solvated by EC, a surprisingly unusual anodic current peak sprouts out during the deintercalation of BF4 from the graphite cathode.6 This phenomenon may be closely related to the following two reasons. First, EC solvent inversely flows from the electrolyte solution into the graphite electrode during the anion deintercalation from graphite into the solution; second, the strong affinity between EC and the anion leads to some BF4 accompanying EC back-flows into graphite. As for the first reason, a similar case may be found in the solution of LiPF6 dissolved in ethyl methyl carbonate.7 But counter current during discharge never appears. Therefore, the second reason must be an indispensable prerequisite to incur the unusual anodic current. To test the above assumption, we tailor the solvation state of BF4 in the electrolyte solution and then correlate it with the generation of unusual anodic current at the graphite cathode in this study. Two series of EC solutions, including those dissolving the ionic liquid of 1-butyl-3-methylimidazolium tetrafluoroborate (BMIMBF4) or the mixed salts of both tetraethylammonium tetrafluoroborate (TEABF4) and hexafluorophosphate (TEAPF6), are applied in the activated carbon/graphite capacitors. The anion–solvent co-intercalation of graphite cathode and multiple signal responses of counter-current is confirmed by X-ray diffraction (XRD), electrochemical dilatometry (ECD), and electrochemical quartz crystal microbalance (EQCM). Moreover, by analysing two-dimensional nuclear magnetic resonance (2D NMR) results, the reverse current can be attributed to the interaction between EC and BF4. This work will help researchers reassess weak interactions in electrolytes and provide new insights into the formulation design of electrolytes for DIBs.

To verify that the unique combination of EC and BF4 is a prerequisite to generating counter current, we gradually added EC into the ionic liquid of BMIMBF4 and then tested the performance of the graphite cathode in the corresponding electrolyte solutions. The reliability of activated carbon quasi-reference electrodes (AC-QRE) has been demonstrated previously.8 As shown in Fig. 1, the counter current does not appear in the case of ionic liquid free of solvent. Instead, the redox peaks stand for reversible storage of “naked” BF4 in graphite electrodes. If the content of EC is less than that of BMIMBF4, the current peaks become weaker with the addition of EC, which implies that EC may suppress the intercalation of BF4. Moreover, there is no counter current at all during the cathodic scan. Once the molar ratio of [EC]/[BMIMBF4] exceeds 1, a significant counter-current peak can be observed. As more and more EC is introduced into the solution, the concentration of BF4 decreases, and the polarization between the anodic and cathodic current peaks gets larger. Accordingly, the counter current looks less pronounced.


image file: d4cc04734f-f1.tif
Fig. 1 Cyclic voltammograms of graphite electrodes in the electrolyte solutions of BMIMBF4-EC in the initial cycle.

The effect of the addition of EC into the ionic liquid on BF4 intercalation into graphite electrodes can be manifested by the ex situ XRD results of graphite electrodes recovered from the AC/graphite cells which were charged to 3.5 V (the specific charge/discharge curves are shown in Fig. S1, ESI). As shown in Fig. 2 (AGICs parameters are shown in Table S1, ESI), the graphite electrode charged in the neat ionic liquid demonstrates diffraction peaks corresponding to AGICs, while the (002) diffraction peak of the original graphite (at 26.5°) is absent, which means that the anion can adequately intercalate into graphite. In contrast, as EC is added into BMIMBF4, little by little, say, the molar ratios of [EC]/[BMIMBF4] amount to 0.57 or 0.29 in the electrolyte solutions, the (002) diffraction peak of the original graphite begins to dominate in the ex situ XRD patterns although there are some parasite peaks standing for the formation of AGICs. This indicates that the intercalation of BF4 into graphite is suppressed somehow. When there is sufficient EC in the electrolyte solutions, for example, the molar ratios of [EC]/[BMIMBF4] are over 1, the (002) diffraction peak of the original graphite becomes apparently weaker than the peaks of AGICs. The stronger intensities of these diffraction peaks of AGICs imply that considerable capacities of the anion intercalate into graphite. These XRD results agree with the trend observed in Fig. 1.


image file: d4cc04734f-f2.tif
Fig. 2 Ex situ XRD patterns of graphite electrodes recovered from the AC/graphite cells charged to 3.5 V by utilizing the electrolyte of BMIMBF4-EC.

In situ XRD characterizations of graphite cathode in AC/graphite capacitors may shed more light on the formation and transformations between AGICs. As shown in Fig. S2 (ESI), for all electrolyte solutions, the anion storage in graphite electrode takes place, as evidenced by the emergence and growth of diffraction peaks of AGICs during the charging process. In contrast, the weakening and disappearance of these peaks during the discharge process occurs. From the in situ XRD patterns in Fig. S2 (ESI), the intercalation gallery heights (IGHs) or stage numbers (SNs) of the AGICs can be calculated according to the methods introduced before.9 These key parameters are plotted with respect to the voltages of AC/graphite cells in Fig. S3 and S4 (ESI). Unfortunately, the signs for counter-current cannot be detected at all. This insensitivity can be ascribed to the limitation of the constant-voltage control on the cells during in situ XRD measurements, which cannot catch up with the instantaneous rise-up of counter current. Table 1 just lists the SNs and IGHs of AGICs corresponding to the AC/graphite cells charged to 3.5 V. The IGHs of AGICs obtained in EC-added solutions (0.807 to 0.817 nm) are apparently larger than those obtained in the neat ionic liquid (0.616 nm). This result strongly supports that the solvent of EC co-intercalates with BF4 into the graphite.

Table 1 Parameters of the anion–graphite intercalation compounds at 3.5 V
Electrolyte solution Basal repeat length along C nm−1 SN IGH/nm
BMIMBF4 1.666 4.14 0.614
EC:BMIMBF4 = 0.29 2.122 4.92 0.809
EC:BMIMBF4 = 0.57 2.301 5.40 0.807
EC:BMIMBF4 = 1.13 2.014 4.59 0.811
EC:BMIMBF4 = 5.13 1.923 4.30 0.817
EC:BMIMBF4 = 9.13 1.840 4.07 0.812


On the other hand, in order to precisely adjust the interactions between BF4 and EC in the solutions, we gradually added 0.1 to 0.5 M TEAPF6 into the 1.5 M TEABF4-EC solution (FT-IR and Raman spectra are shown in Fig. S5a and b, ESI). Since EC-solvated PF6 hardly intercalates into graphite electrodes, the AGICs formed in the above solutions may be only ascribed to EC-solvated BF4. In other words, PF6 will seldom interfere with the solvated BF4, which is already intercalated into graphite, but it exerts its impact out of the graphite electrode. As shown in the cyclic voltammograms of graphite electrodes in these solutions (Fig. 3), the addition of TEAPF6 does take effect in suppressing the counter current. When the dose of TEAPF6 reaches 0.3 M, the counter current disappears.


image file: d4cc04734f-f3.tif
Fig. 3 Cyclic voltammograms of graphite electrodes in the electrolyte solutions of (TEABF4 + TEAPF6)-EC in the initial cycle.

To further address the instantaneous nature of counter-current, more in situ characterization is necessary. Herein EQCM (Schematic Diagram is shown in Fig. S6, ESI) and ECD were chosen to capture this transient process. As shown in Fig. 4a, for the solution of 1.5 M TEABF4-EC, during the charging process, the electrochemical intercalation gradually occurs and then generates anodic current as the potential climbs up. Meanwhile, the frequency of the quartz crystal electrode gradually decreases with the increase in current until the peak. According to the Sauerbrey equation, the corresponding electrode mass also reaches the maximum peak. Afterward, the concentration of BF4 on the graphite electrode surface decreases to 0, therefore, this electrochemical reaction is controlled by the anion diffusion inside the graphite. With an increase in potential, the diffusion layer gradually spreads out, and then the proceeding rate of anion intercalation becomes sluggish. If the charging process only involves BF4 intercalation, the mass of the graphite electrode must continue to increase, but at a decreasing pace. However, in reality, after the current reaches its maximum peak, the mass of the graphite electrode drops down quickly. This phenomenon corresponds to the mass loss during BF4 intercalation, which has been attributed to the release of some EC from the AGICs based on EC-solvated BF4.6,10 During discharge, a sharp anodic current peak jumps out at first along with the cathodic scan, and then follows two cathodic current peaks at lower potentials. Simultaneously, an anomalous increasing mass peak was observed in the frequency variation curve. This indicates the reverse entry of charged species into the graphite electrode during the deintercalation process, causing both mass and current-increasing responses. Consistent with our previous study,6 the anion undergoes re-solvation when it deintercalates from graphite electrodes, resulting in the reflux of EC into the graphite. More importantly, BF4, the charge carrier on the electrode surface, was driven back into graphite by the strong binding between the solvent and the anion, leading to the generation of counter current. As shown in Fig. 4b, the mass change during the charging process of the graphite electrode in the electrolyte containing TEAPF6 is similar to that of 1.5 M TEABF4-EC. However, there is no abnormal mass increase in the frequency variation curve during the discharge process. This can be attributed to the weakening of the interaction between BF4 and EC due to the addition of PF6.


image file: d4cc04734f-f4.tif
Fig. 4 CV–QCM curves of graphite electrode in the (a) 1.5 M TEABF4-EC and (b) 1.5 M TEABF4 + 0.3 M TEAPF6-EC electrolyte solution.

The ECD results will provide more insights into the switch-off of counter-current after introducing bits of TEAPF6. As exhibited in Fig. 5a, the graphite electrode gradually expands from the voltage of about 2.5 V due to the continuous intercalation of anions in the 1.5 M TEABF4-EC electrolyte. Subsequently, the thickness of the graphite decreases steadily during discharge. It is noteworthy that BF4 intercalates into graphite accompanied by EC on the electrode surface at approximately 2.8 V, which causes a tiny bulge of the ECD curve. On the contrary, there is no such sign in Fig. 5b. Conductivity of electrolyte, interface analyses, and kinetic analyses of graphite positive electrodes are shown in Fig. S7–S10, and Table S2 (ESI).


image file: d4cc04734f-f5.tif
Fig. 5 ECD curves of graphite electrode in the (a) 1.5 M TEABF4-EC and (b) 1.5 M TEABF4 + 0.3 M TEAPF6-EC electrolyte solution.

It has been reported that the weakly polarized hydrogen atoms of C–H bonds can act as hydrogen bond donors for anions, especially when several such interactions work in concert.11,12 Employment of electron withdrawing groups, such as a somewhat distant positive charge can reinforce these otherwise weak C–H⋯anion interactions.13,14 We hypothesize that changes in the solvation structure of EC-BF4 by PF6 are eventuated from the different hydrogen bonding interactions. To verify it, 1H–19F 2D heteronuclear Overhauser effect spectroscopy (HOESY, whose signal strength is related to the spatial distance between the atoms) was employed to differentiate the interaction strengths between EC and BF4 or PF6.15,16 In order to maintain an equal total number of F atoms from both anions, our research focuses on a 0.9 M TEABF4 + 0.6 M TEAPF6-EC electrolyte solution as the experimental system. As shown in the 19F horizontal trace projection of the contour map of Fig. 6, the signals of BF4 and PF6 located at −153.6 and −72.9 ppm, respectively.16,17 As for 1H, both EC solvents and TEA+ cations appear in the vertical trace projection of the contour map of Fig. 6.18 Herein, the interaction between anions and solvents can be compared qualitatively in terms of the intensity of the cross peak. 1H atoms in EC approach 19F of BF4 and exhibit a stronger relation to it instead of PF6. Therefore, it can be foreseen that the interaction of the hydrogen bonding network will be weakened, when some PF6 partially replaces BF4 around the EC. So as to confirm it, further investigation was conducted on the 1H and 19F NMR spectra for the 1.8 M TEABF4-EC and 1.5 M TEABF4 + 0.3 M TEAPF6-EC solutions shown in Fig. 7a and b. While total concentration is controlled at 1.8 M, the chemical shift of 1H in EC moves upfield in the 0.3 M TEAPF6 + 1.5 M TEABF4, indicating an increase in electron cloud density and a stronger shielding effect around the H nuclei of EC. Additionally, the chemical shift of 19F moves downfield, suggesting a decrease in electron cloud density around the F nuclei of BF4, which implies weakened interaction between the F anions and the solvent H atoms. Given the potential influence of higher concentrations of salt on the manifestation of C–H⋯anion interactions in the NMR spectra, which result from the presence of contact ion pairs and aggregates, we chose to employ a lower electrolyte concentration of 1 M to ensure sufficient solvent for electrolyte dissociation, as shown in Fig. S11 (ESI). As the concentration of PF6 increases, the chemical shift of 1H in EC moves towards upfield, while the strength of C–H⋯anion interactions decreases. It also supports the aforementioned conclusion. The addition of PF6 weakens the interaction of EC-BF4, making it challenging for EC to effectively capture BF4 during its reverse flow into the graphite.


image file: d4cc04734f-f6.tif
Fig. 6 1H–19F HOESY spectra for the 0.9 M TEABF4 + 0.6 M TEAPF6-EC electrolyte solution.

image file: d4cc04734f-f7.tif
Fig. 7 (a) 1H and (b) 19F NMR spectra for the 1.5 M TEABF4 + 0.3 M TEAPF6-EC and 1.8 M TEABF4-EC solutions.

In summary, the electrochemical processes of anion intercalation and deintercalation in graphite electrodes are greatly influenced by their solvation state. The storage behavior of BF4 inside the graphite cathode varies with the molar ratios of [BMIMBF4]/[EC] in the corresponding electrolyte solutions. The back-flows of EC solvent from the electrolyte solution into the graphite electrode, in conjunction with the strong affinity between EC and the anion, result in the generation of a counter-current during BF4 deintercalation. NMR spectra have confirmed that this strong affinity originates from solvent-anion hydrogen bonding interactions. By introducing PF6 into the electrolyte, the counter current was successfully controlled through the modulation of long-range interaction between anion and solvent. In addition, another electrolyte was also studied to investigate the universality of the counter-current (Fig. S12, ESI). Anion solvation in electrolytes can change the electrochemical performance of the electrolytes, but it has been rarely investigated. This unexplored area has begun to show its potential in rational electrolyte design for lithium metal batteries19,20 and is also anticipated to bring unique insights into the field of dual-ion batteries involving anion participation in intercalation.

This work was financially supported by the National Key R&D Program of China (2022YFB2402600).

Data availability

The data supporting this article have been included as part of the ESI.

Conflicts of interest

There are no conflicts to declare.

References

  1. H. Guo, M. Elmanzalawy, P. Sivakumar and S. Fleischmann, Energy Environ. Sci., 2024, 17, 2100 RSC.
  2. J. Li, C. Han, X. Ou and Y. Tang, Angew. Chem., Int. Ed., 2022, 61, e202116668 CrossRef CAS.
  3. Z. Zhao and H. N. Alshareef, Adv. Mater., 2024, 36, 2309223 CrossRef CAS.
  4. X. Tong, X. Ou and Y. Tang, Adv. Energy Mater., 2021, 11, 2100151 CrossRef CAS.
  5. J. Lang, Y. Liu and Y. Tang, Small, 2024, 2401200 CrossRef CAS.
  6. Y. Huang, J. Li and H. Wang, ACS Appl. Energy Mater., 2019, 2(6), 4544–4550 CrossRef CAS.
  7. D. Zhu, L. Zhang, Y. Huang, J. Li, H. Fan and H. Wang, ACS Appl. Energy Mater., 2019, 2(11), 8031–8038 CrossRef CAS.
  8. P. W. Ruch, D. Cericola, M. Hahn, R. Kotz and A. Wokaun, J. Electroanal. Chem., 2009, 636, 128–131 CrossRef CAS.
  9. M. S. Dresselhaus and G. Dresselhaus, Adv. Phys., 1981, 30(2), 139–326 CrossRef CAS.
  10. J. Gao, M. Yoshio, L. Qi and H. Wang, J. Power Sources, 2015, 278, 452–457 CrossRef CAS.
  11. Y. J. Li and A. H. Flood, Angew. Chem., Int. Ed., 2008, 47, 2649–2652 CrossRef CAS PubMed.
  12. B. J. J. Timmer and T. J. Mooibroek, Chem. Commun., 2021, 57, 7184–7187 RSC.
  13. J. J. Cai and J. L. Sessler, Chem. Soc. Rev., 2014, 43, 6198–6213 RSC.
  14. B. W. Tresca, R. J. Hansen, C. V. Chau, B. P. Hay, L. N. Zakharov, M. M. Haley and D. W. Johnson, J. Am. Chem. Soc., 2015, 137, 14959–14967 CrossRef CAS.
  15. I. Fernandez and P. S. Pregosin, Magn. Reson. Chem., 2006, 44, 76–82 CrossRef CAS PubMed.
  16. Y. Wang, J. Li, Y. Huang and H. Wang, Langmuir, 2019, 35(46), 14804–14811 CrossRef CAS PubMed.
  17. M. Nie, D. Chaalasani, D. P. Abraham, Y. Chen, A. Bose and B. L. Lucht, J. Phys. Chem. C, 2013, 117(3), 1257–1267 CrossRef CAS.
  18. C. Jehanno, J. Demarteau and H. Sardon, Angew. Chem., Int. Ed., 2021, 60, 6710–6717 CrossRef CAS PubMed.
  19. J. Xu, V. Koverga, A. Phan, A. M. Li, N. Zhang, M. Baek, C. Jayawardana, B. L. Lucht, A. T. Ngo and C. Wang, Adv. Mater., 2024, 36, 2306462 CrossRef CAS.
  20. Y. Tian, S. Tan, Z. Lu, D. Xu, H. Chen, C. Zhang, X. Zhang, G. Li, Y. Zhao, W. Chen, Q. Xu, R. Wen, J. Zhang and Y. Guo, Angew. Chem., Int. Ed., 2023, 62, e202305988 CrossRef CAS PubMed.

Footnote

Electronic supplementary information (ESI) available. See DOI: https://doi.org/10.1039/d4cc04734f

This journal is © The Royal Society of Chemistry 2024
Click here to see how this site uses Cookies. View our privacy policy here.