Open Access Article
This Open Access Article is licensed under a
Creative Commons Attribution 3.0 Unported Licence

Synthesis of a Au/Au NPs-PPy/L-CYs/ZIF-8 nanocomposite electrode for voltammetric determination of insulin in human blood

Jamal Kouhdareha, Rahman Karimi-Namib, Hassan Keypour*a, Khadijeh Rabiei*c, Sedigheh Alaviniaa, Shokoufeh Ghahri Saremid and Mohammad Noroozie
aFaculty of Chemistry, Bu-Ali Sina University, Hamedan 65174, Iran. E-mail: haskey1@yahoo.com
bDepartment of Chemistry, Faculty of Science, University of Maragheh, Maragheh, Iran
cDepartment of Chemistry, Faculty of Science, Qom University of Technology, Qom, Iran
dDepartment of Chemistry, Payame Noor University, Tehran, Iran
eCenter for Research and Development of Petroleum Technologies at Kermanshah, Research Institute of Petroleum Industry (RIPI), Iran

Received 16th June 2023 , Accepted 31st July 2023

First published on 16th August 2023


Abstract

In this work, a modified electrode named Au/Au NPs-PPy/L-CYs/ZIF-8 was designed and built and simultaneously doped into electropolymerized polypyrrole (PPy) film using cyclic voltammetry (CV). Scanning Electron Microscopy (SEM), Electrochemical Impedance Spectroscopy (EIS), and CV were used to characterize the composite films. The PPy-(ZIF-8) modified Au electrode was used to determine insulin using Square-Wave Voltammetry (SWV). It was found that the prepared zeolitic imidazolate framework-8 had excellent electrocatalytic activity towards insulin oxidation due to its unique properties. The oxidation peak current of insulin hormone increased with its concentration in the range from 1.0 to 60 nM with the linear regression equation: Ipa = 0.3421C (nM) + 3.2762 (γ = 0.998). The measurement limit was estimated to be 1 nM. While the common coexisting substances showed no interference in the response of the modified electrode to insulin, the modified electrode indicated reproducible behavior and a high level of stability during the experiments. The advantages of using these nanocomposites on the surface of modified electrodes include increased stability, good interaction between the analyte and the modified electrode, conductivity, and excellent performance due to the nanometer size of the composites. As a result, it may be particularly suitable for analytical purposes.


1 Introduction

Insulin is a hormone made in the pancreas, a gland located behind the stomach, and is an essential polypeptide hormone that controls glucose levels in the blood. It is used for the treatment of insulin-dependent type I diabetes. The standard analytical methods for insulin identification and measurement in serum samples include bioassays, immunoassays, and chromatography. Direct and rapid electrochemical measurement of insulin is therefore essential and crucial. Some previous studies have already been reported about in vitro electrochemical insulin measurement using modified common electrodes as a sensing platform, which is a cheaper method with higher efficiency and lower cost.1–3

However, direct electrochemical measurement of insulin is fast, simple, and of low-cost. Also, it is attractive as it can provide sensitivity and reduces analysis time to enable frequent real-time measurements compared to the standard analytical methods. Biosensor-related research and studies have experienced explosive growth over less than two decades. An electrochemical biosensor is an analytical sensing device that transduces biochemical events to electrical signals.4,5 The purpose of designing and manufacturing a chemical sensor is to provide reliable information about the chemical composition and structure in the shortest possible time. Ideally, such a device can respond continuously and reversibly and does not perturb the sample. This class of sensors consists of a transmission element coated with a chemical and biological detection layer or film composite. In the case of electrochemical sensors, the analytical information is obtained from the electrical signal that results from the interaction of the target analyte and the recognition layer. To investigate the electrochemical oxidation of insulin hormone, various chemically modified electrodes have been made with features such as being fast response, inexpensive, and measurement in situ conditions.6–9 Zeolitic imidazolate frameworks (ZIFs) and Metal–organic frameworks (MOFs) have received significant attention in the last decade due to their unique properties different from those of bulk materials, such as top conductivities, outstanding electrocatalytic activities, optical and electrochemical properties.10–19 Notably, gold nanoparticles (GNPs) have been widely used in many electrochemical fields due to their potential for catalysis, mass transport, and high effective surface area.20 The catalytic performance of GNPs significantly depends on the structure of the local microenvironment.21–23 ZIF-8 based on Zn2+ has been extensively studied in the drug delivery system due to its low toxicity and good biocompatibility.24

Zeolitic imidazolate frameworks (ZIFs) show conductivity properties according to excellent electrical conductivity above their inherent qualities, highly available specific surface, and metal coordination to organic ligands.25–27 Transition metals are essential in biological systems because they have multiple oxidation states separated by only modest potentials, which make them suitable candidates for electron-transfer processes. ZIF-8 shows high catalytic activity in the oxidation of some organic compounds compared to other (incredibly noble metal) catalysts inexpensively.28–30 Keypour et al. reported a new Schiff base functionalized magnetic Fe3O4 nanoparticle/MWCNTs modified glassy carbon electrode to determine citalopram in human blood serum samples.4

In this work, we have reported the synthesis of a PPy-(ZIF-8) modified Au electrode prepared by the modifier's electrochemical-pulsed potential deposition and the application of its electrochemical behavior in the voltammetric determination of insulin. The zeolitic imidazolate framework-8 (ZIF-8) was synthesized based on previous reports, and it was proposed to be fully compatible with the criteria of making an excellent sensor.31

2 Experimental

2.1 Reagents and chemicals

All compounds and chemicals used in this project were obtained from Merck and Sigma companies. Britton–Robinson buffer (aka BRB aka PEM) is a “universal” pH buffer used for the pH range from 2.0 to 12.0. Data from electrochemical interactions were performed using an auto-lab potentiostat model PGstat302N (Metrohm). The working system consists of three electrodes comprised of a modified working electrode as Au/Au-PPy-ZIF-8, a saturated Ag/AgCl electrode as a reference electrode, and a platinum wire as a counter electrode. All reported potentials are based on Ag/AgCl reference criteria. A scanning electron microscope (SEM, PhilipsXL30) with gold coating characterized the surface morphology of modified electrodes.

2.2 Synthesis of zeolitic imidazolate framework-8 (ZIF-8)

In Fig. 1, the schematic route of ZIF-8 synthesis was provided by following the Pan Y., et al. and colleagues' method in an aqueous solution at room temperature.32 In the initial step, the solution was prepared with a molar ratio of Zn2+[thin space (1/6-em)]:[thin space (1/6-em)]2-methyl-2H-imidazole[thin space (1/6-em)]:[thin space (1/6-em)]water = 1[thin space (1/6-em)]:[thin space (1/6-em)]70[thin space (1/6-em)]:[thin space (1/6-em)]1238. Next, we dissolved 0.585 g of zinc nitrate in 4 mL of distilled water. In the next step, 11.35 g of 2-methyl-2H-imidazole was dissolved in 40 mL of distilled water, and then 6 mL of DMSO was added to it. Then, zinc nitrate solution was added to the ligand solution, and a milky white solution was formed quickly. The synthesized solution was centrifuged, and after sedimentation, we washed the sediment several times with distilled water to remove unreacted and excess materials and dried it in the oven at 60 °C for 24 h.33–36
image file: d3ra04064j-f1.tif
Fig. 1 Crystal structure of ZIF-8: Zn (polyhedral), N (sphere), and C (line).

2.3 Electrode modification

The general schematic of modification of the Au bare electrode is shown in Fig. 2. For electrode modification, the emery paper was used for polishing the Au bare electrode, followed by alumina (1.0 and 0.05 mm), and deionized water was applied for washing thoroughly. Then, the Au nude electrode was placed in a beaker containing water and ethanol and transferred to an ultrasonic bath to remove contamination on the electrode surface. The Au bare electrode was immersed into the solution containing 2 mL of 3% (v/v) PPy and 2 mL of 1 mM of HAuCl4·3H2O in 25 mL of deionized water under applying cyclic voltammograms from +1.5 to −1.5 V (N = 12). The modified Au/Au NPs-PPy was preserved in a solution of L-cysteine (5 mol L−1) for 24 h at room temperature to produce Au/Au NPs-PPy/L-CYs. The modified electrode was immersed in deionized water to repulse physically absorbed L-CYs. In a separate experiment, 35 mg of trifluoromethane sulfonic anhydride (TF2O) (0.125 mmol) and 0.05 g of ZIF-8 were mixed well by the ultrasonic bath at 40 °C. Afterward, for 6 h, the modified Au/Au NPs-PPy/L-CYs electrode was dipped into the dispersed solution containing ZIF-8 under stirring. Therefore, the final Au/Au NPs-PPy/L-CYs/ZIF-8 was prepared and used to determine insulin hormone.
image file: d3ra04064j-f2.tif
Fig. 2 Overall scheme for the preparation of Au/Au NPs-PPy/L-CYs/ZIF-8 nanocomposite electrode.

2.4 Human serum sample preparation

Serum samples were obtained from a healthy volunteer and stored frozen until assay. After gently thawing, an aliquot sample volume was fortified with RBV dissolved in bidistilled water to achieve appropriate concentration. The solution was centrifuged for 30 min at 3600 rpm to remove the precipitated serum protein, and the supernatant was taken carefully. The appropriate volume of the supernatant liquor was transferred to the voltammetric cell.37

2.5 The vial hormone preparation

The proposed built electrode analyzed hormone vial formulations containing insulin. 5 vials containing 1.30 mg (4 IU) per one of insulin were mixed well to calculate the average vial contents. One-fifth of the solution was taken, transferred to a 100 mL bottle, and made up to volume with 0.5 mol L−1 NaNO3. The using Briton–Robinson buffer in the pH range was stabilized at 7.0. 1 mL of this solution was transferred to the volumetric flask and was made up to 100 mL with distilled water. This diluted solution was used in quantitative and qualitative analysis.

3 Results and discussion

3.1 Characterization of the Au/Au NPs-PPy/L-CYs/ZIF-8 nanocomposite electrode

In the FT-IR spectrum of the ZIF-8, a broad peak in the region of 3500 cm−1 is related to the stretching bond of N–H, and the small peak in the area of 3162 cm−1 can be attributed to C–H stretching in the vibrational modes inside the imidazole ring which is attached to the methyl group.38–40 The long peak in the region of 1610 cm−1 can be related to the C[double bond, length as m-dash]N stretching states, and the peak in the area of 1394 cm−1 is associated with the stretching inside the ring.41 The peak is observed in the region at 480 cm−1, which is related to the Zn–N stretching in the ZIF-8 structure because the zinc atoms in the ZIF-8 structure bond to the nitrogen atoms in 2-methyl-2H-imidazole; they are connected in the direction of ZIF-8 formation (Fig. 3).
image file: d3ra04064j-f3.tif
Fig. 3 FT-IR spectra of ZIF-8.

The overall XRD pattern of ZIF-8 (A) obtained with characteristic peaks (011), (002), (112), (022), (013), (222), (116), and (237) was in good agreement with the literature values and confirmed the formation of ZIF-8 crystal structure42–44 (Fig. 4A). Several diffraction peaks confirm the polycrystalline step in the pattern. From the XRD pattern, (Cs) is the average crystallite size, and the dislocation density is (D) can be determined as follows: eqn (1) and (2).

 
image file: d3ra04064j-t1.tif(1)
 
image file: d3ra04064j-t2.tif(2)
\where λ is the wavelength of X-ray radiation (λ = 1.5406 Å), θ is the angle of diffraction, and β1/2 is the complete width measured in radians at half the maximum reference diffraction peak.45,46 The obtained value is 100 nm, consistent with the result measured from the SEM images.12,47 In Fig. 4B, the morphology of the ZIF-8 surface can be seen by scanning electron microscope (SEM), which is consistent with the previously synthesized samples.48


image file: d3ra04064j-f4.tif
Fig. 4 XRD patterns for simulated ZIF-8 (JCPDS 00-062-1030) (A), FESEM micrographs of (B) pure ZIF-8.

In Fig. 5A, the result of the energy dispersive X-ray analysis (EDX) of ZIF-8 indicates the presence of expected elements of C, N, and Zn in the crystal structure of the ZIF-8 composition. The presence of a small amount of oxygen atoms can be due to the presence of some water molecules encapsulated in ZIF-8 cavities. N2 adsorption/desorption techniques were used to determine the surface structural parameters. Fig. 5B shows the result of the N2 adsorption/desorption analysis related to the composition of ZIF-8. The surface area obtained based on the BET isotherm is 145.20 m2 g−1, and the total pore volume of the catalyst is 0.194 cm3 g−1. The adsorption isotherm is of type III, and the appearance of a hysteresis loop indicates the presence of mesopores in the sample.49


image file: d3ra04064j-f5.tif
Fig. 5 Energy dispersive X-ray analysis (EDX) ZIF-8 (A) Brunauer–Emmett–Teller (BET) (B) ZIF-8.

3.2 Electrochemical characterization of the Au/Au NPs-PPy/L-CYs/ZIF-8 nanocomposite film

In biosensors, information is extracted by measuring electrical properties to determine the electrochemical nature of the target element. This transfer of information and identification is due to the biocatalytic activity of biological compounds with the desired sensor.50,51 The electrochemical behavior of Au-PPy − Au/PPy + Au NPs/L-cysteine/ZIF-8 crystalline structure toward insulin was studied using square-wave (SW) and cyclic voltammetry (CV). CV measurements, insulin gave a well-defined cathodic peak in the serum sample, indicating that bonds N–Zn were reduced. Electropolymerization is widely accepted as an appropriate methodology for preparing suitable nanomaterials. Electropolymerization is one of the proper methods for preparing nanomaterials or loading them on surfaces. The main advantage of this method is that the thickness or diameter of the layers of the synthesized particles can be controlled. The increase of ZIF-8 in this polymer matrix increases the electrochemical activity/conductivity due to the high available cross-sectional area and excellent conductivity in this substrate. So, cyclic voltammograms of analyzes of 20 nM of insulin response at a scanning rate of 100 mV s−1 on the surface of different film sensors such as Au-PPy – Au/PPy + Au NPs/L-cysteine/ZIF-8 crystalline structure electrodes were performed in pH 7.00.52

As shown in Fig. 6, the absence of any electrochemical response at the Au bare electrode indicates that the electrooxidation/reduction of 20 nM insulin is difficult to understand in the commonly applied working electrode. Small peaks appeared on the Au/PPy electrode, which could be ascribed to the facile electrochemical oxidation/reduction of insulin. Due to the Au NPs specific properties in the conductive polymer matrix with definite electrocatalytic capability, the electro-reduction of insulin was improved. The reduction peak considerably appeared by visibly enhancing the reduction peak current on Au/Au NPs-PPy/L-CYs/ZIF-8 crystalline structure. The results indicated that the zeolitic imidazolate frameworks (ZIFs) presence in the film sensor exhibited promoting effects for insulin reduction. The appearance of a small reduction peak at +0.20 V (curve B) at the Au/PPy electrode can be attributed to the easy electrochemical reduction of insulin. On Au/PPy + Au NPs/L-cysteine/ZIF-8 crystalline, the reduction peak significantly appeared at +0.40 V with the obvious increase of the reduction peak current (curve E). The results indicated that the presence of ZIF-8 in the film sensor exhibits promoting effects for insulin reduction. The synthetic Au/PPy + Au NPs/L-cysteine/ZIF-8 acts as an electron mediator substance in the film sensor to accelerate the electron transfer of the electrochemical process, and it is worth mentioning that cyclic voltammetry is a reversible process.


image file: d3ra04064j-f6.tif
Fig. 6 Cyclic voltammograms of (A) Au bare electrode, (B) Au/PPy electrode, (C) Au/PPy + Au NPs electrode, (D) Au/PPy + Au NPs/L-cysteine electrode, and (E) Au/PPy + Au NPs/L-cysteine/ZIF-8 crystalline structure electrode in 20 nM of insulin hormone solution (pH 7) at and scan rate 100 mV s−1.

3.3 Surface characterization of Au/PPy + Au NPs/L-cysteine/ZIF-8 crystalline

The morphology of the obtained Au/PPy + Au NPs/L-cysteine/ZIF-8 film was also observed by SEM (Fig. 7). The SEM image of ZIF-8 suggests a smooth morphology and confirms that the particles still fall in the Nano-size range. In addition, the SEM images show the successful polymerization of the matrix on the surface of the gold electrode.
image file: d3ra04064j-f7.tif
Fig. 7 SEM image for bare Au (A) and Au/PPy + Au NPs/L-cysteine/ZIF-8 crystalline (B) modified electrodes.

Electrochemical Impedance Spectroscopy (EIS) can provide information about the impedance changes of the modified electrodes during the modification process and increase the electrical resistance of the modified layers. Fig. 8 shows the typical EIS results for different modified electrodes in 10.0 mM K3Fe(CN)6/K4Fe(CN)6 solution and 0.5 mol L−1 KI with frequencies ranging from 100[thin space (1/6-em)]000 to 0.1 Hz.53 The semicircle with a small diameter belongs to the bare electrode of gold, and this small conductivity is due to the inherent properties of gold (Fig. 8, curve A). With the increase of the layers on the surface of the electrode (Fig. 8, B–E curves), the observation of the increase in the diameter of the semicircles in this graph proves the coating layer's success in increasing the efficiency of the electrode. This phenomenon is likely due to the excitation of the PPy and Au/PPy + Au NPs/L-cysteine/ZIF-8 crystalline doped into the film electrodes, which enhances the resistance of the films.


image file: d3ra04064j-f8.tif
Fig. 8 The electrochemical impedance of (A) Au bare electrode, (B) Au/PPy electrode, (C) Au/PPy + Au NPs electrode, (D) Au/PPy + Au NPs/L-cysteine electrode, and (E) Au/PPy + Au NPs/L-cysteine/ZIF-8 crystalline structure in the presence of a solution of 10.00 mmol L−1 [Fe(CN)6]3−/4−, 0.5 mol L−1 KI with the frequencies ranging from 100[thin space (1/6-em)]000 to 0.1 Hz.

3.4 Effect of pH

The influence of pH on the electrochemical response of insulin hormone was examined with the results shown in (Fig. 9A). A stable and pretty well-defined irreversible oxidation peak was obtained in the pH range of 2.0–12.0. Due to the presence of the C[double bond, length as m-dash]O group on the structure of insulin hormone, its electrochemical behavior strongly depends on the pH of the test solutions. The oxidation peak currents increased with the increase of buffer pH until it reached 7, then the peak currents decreased gradually with the further increase of pH value. So pH 7.0 B–R buffer was used as the supporting electrolyte in the following experiments.
image file: d3ra04064j-f9.tif
Fig. 9 (A) The effect of pH on the reduction peak current response of 20 nM insulin in 2.5 mM 0.1 mol L−1 pH 6.0 B–R buffer solution at scan rate 100 mV s−1. (B) The plot of E00 vs. pH for Au/PPy + Au NPs/L-cysteine/ZIF-8 crystalline modified Au electrode.

Fig. 9B shows that the formal value of E0′ is linear with pHs and a slope of 0.0035 mV pH−1 for insulin. These slopes correspond to the electron transfer process for insulin reductions at the surface of the modified electrode. It has been reported that insulin is an essential component of the electron transport chain in mitochondria with the electron transfer process.54

3.5 Influence of the scan rate

With the increase of the scan rate (100–500 mV s−1), the oxidation/reduction peak currents gradually increased with the positive shift of the reduction peak potential, which indicated that the electrode process was irreversible. The oxidation peak current showed a good linear relationship with the scan rate in the range from 100 to 500 mV s−1, and the linear regression equation was calculated as Ipa (μA) = 0.418θ (mv s−1) + 22.12 (n = 2, δ= 0.994). The results showed that the electrode process was controlled by adsorption.55
 
image file: d3ra04064j-t3.tif(3)
 
image file: d3ra04064j-t4.tif(4)

The electrochemical parameters, such as the charge transfer coefficient (α) and the electrode reaction standard rate constant (ks), were calculated with the results as 0.74 and 3.36 × 10−4 s−1, respectively. Since the electrode process was controlled by adsorption, the adsorption amount of electroactive insulin hormone on the Au/PPy + Au NPs/L-cysteine/ZIF-8 modified Au electrode was calculated by the down eqn.

 
image file: d3ra04064j-t5.tif(5)
where n is the number of electrons transferred, F(C mol−1) is Faraday's constant; A (cm2) is the area of the electrode, Γ (mol cm−2) is the surface concentration of the electroactive substance, i.e., insulin hormone, Q (C) is the peak area (calculated by the charges) and ν (V s−1) is the scan rate. By integrating the relationship of ip with ν, the values of n and Γ were obtained by the results as 1.75 and 7.82 × 10−10 mol cm−2, respectively. The results indicated that the presence of Au/PPy + Au NPs/L-cysteine/ZIF-8 on the electrode surface provided a nanostructure for the effective electrochemical reduction of insulin hormone on the surface of the final modified electrode, which resulted in the improvement of the sensitivity (Fig. 10).


image file: d3ra04064j-f10.tif
Fig. 10 The plot of peak currents vs. scan rate (inner to outer) 100, 200, 300, 400, and 500 mV s−1 of 20 nM insulin hormone at the modified electrode in pH 7.0 B–R buffer solution.

3.6 Calibration curve

By using the more sensitive SWV, the proposed electrode was further used for the insulin hormone measurement with the typical voltammograms shown in Fig. 11. Under the optimal conditions, the oxidation peak current of insulin hormone increased with its concentration in the range from 1.0 to 60 nM with the linear regression equation as Ipa = 0.3421C (nM) + 3.2762 (γ = 0.998) The measurement limit was estimated to be 1 nM.
image file: d3ra04064j-f11.tif
Fig. 11 The plot of peak currents vs. insulin hormone concentrations.

3.7 Study stability and selectivity sensor

The reproducibility and stability of the sensor were also studied. Seven Au/PPy + Au NPs/L-cysteine/ZIF-8 modified Au electrodes were investigated in 20 nM insulin hormone at a scan rate of 100 mV s−1. The relative standard deviation (R.S.D.) was 3.3%, validating that the preparation method was extremely reproducible. The stability of the modified electrode was tested by scanning the electrode continuously in 20 nM insulin hormone. It was shown that there was no significant decrease in the current response for 14 successive consecutive cycles, resulting in good stability of the modified electrode. The long-term stability of the sensor, also assessed after one month by measuring its current response toward the hormone insulin, was 5.6% relative standard deviation (R.S.D.). Selectivity is the most important characteristic of any sensor toward the target ion in the presence of interfering species. This study was conducted under the optimum conditions for 20 nM of insulin hormone. A relative error of 6% concerning the insulin hormone signal was considered tolerable. The results are shown in Table 1.
Table 1 This table shows that the proposed sensor is accurate, precise, and free from the side interferences in the applied potential window
Interfering ion Toleratedratio [interference]/[insulin hormone] Interfering ion Tolerated ratio [interference]/[insulin hormone]
Cu2+ 810 Ni2+ 741
Zn2+ 379 Mn2+ 754
K+ 914 Co2+ 854
Vitamin B6 751 Al3+ 874
Vitamin E 1125 Fe2+ 752
D-Argenine 795 Glucose, tartarate 981
Sucrose, fructose, glucose 986 CTAB, thiourea, urea 1254


3.8 Analytical application of the proposed sensor

To specify the electrochemical response of the proposed sensor towards insulin hormone in the pharmaceutical and human blood serum samples, the samples were pre-treated in the appropriate manners explained and analyzed by the proposed sensor at pH 7. The results are shown in Tables 2 and 3. The results obtained by the proposed sensor agree with the initial values.
Table 2 Found value by the proposed sensor (nM)a
Sample Spiked (nM) Found value by the proposed sensor (nM)

image file: d3ra04064j-t6.tif

a H.B.S. = human blood serum sample.
H.B.S. 0 0.98 ± 0.09 9.18
H.B.S. 5 5.53 ± 0.38 6.87
H. B. S. 10 10.70 ± 0.66 6.16
H.B.S. 15 15.90 ± 0.92 5.78
H.B.S. 30 31.54 ± 1.42 4.50
H.B.S. 40 41.90 ± 1.80 4.29


Table 3 Found Value by the Proposed Sensor (μg mL−1)
Sample (vial) Ingredient Initial value insulin hormone (μg mL−1) Found value by the proposed sensor (μg mL−1)
GentleJintropin insulin hormone (vial) by GeneScience pharmaceuticals Co. Ltd: China Insulin hormone: 4 i.u./1 vial 1300 1333.7 ± 35.3
Insulin hormone Asia Pharma Co. Ltd: Indonesia (http://www.vitalitypharm.com/asia-pharma.php) hGH: 4 i.u./1 vial 1300 1328.3 ± 29.7


Different nano-modified carbon electrodes for non-immune insulin detection and their analytical performance, e.g., linear concentration range, limit of detection, pH, and sensitivity, are summarized in Table 4.

Table 4 Nano-modified electrodes for non-immune insulin detection and their analytical performancesa
Electrode matrix Linear concentration range Limit of detection Sensitivity Size of nanoparticles pH Reference
a AgNF silver nanoflower, CE carbon electrode, CNTs carbon nanotubes, GN graphene, ITO indium tin oxide, rGO reduced graphene oxide, SPCE screen printed carbon electrode.
SiO2NPs/CE 10–560 nM 36 pM 107.3 pA pM−1 7.4 56
rGO/GCE 4–640 nM 350 pM 7.1254 nA nM−1 7.4 57
Ni(OH)2-GN/GCE 800–6400 nM 200 nM 11 58
NiONPs-Guanin/GCE 4 μM 22 pM 100.9 pA pM−1 70–250 nm 7.4 59
SiCNPs-Nafion/GCE 600 pM 3.3 pM 710 pA pM cm−2 <20 nm 7.4 60
SiO2NPs-Nafion/GCE 3.1 nM 300 pA nM−1 30–40 nm 7.3 61
CNTs-Chitosan/GCE 0.1–3 μM 30 nM 135 mA M cm−2 7.4 62
RuO-CNTs/GCE 10–800 nM 1 nM 40-nm diameter 7.4 63
MWCNTs-NiCoO2-Nafion/SPCE 0.1–31.5 μg mL−1 0.22 μg mL−1 22.57 μA mg−1 mL−1 6–13 diameter 7.5 64
NiONPs-Nafion-MWCNTs/SPCE 20–260 nM 6.1 nM 1.83 mA mM−1 <30 nm (NiONPs) 7.4 65
Au/PPy + Au NPs/L-cysteine/ZIF-8 crystalline 1.0–60 nM 1 nM 7.82 × 10−10 mol cm−2 <100 nm 7.0 This work


4 Conclusions

Zeolitic imidazolate framework-8 (ZIF-8) was successfully synthesized and identified in this study. Next, the fabricated electrochemical nanosensor was tested by reducing the oxidation potential and improving the current conductivity to increase the selectivity and sensitivity in identifying insulin hormones in human biological samples. The results were found to be successful. Also, side interferences and stability of the electrode were investigated, which shows the suitability of this system and its applicability in similar projects. This study was conducted under the optimum conditions for 20 nM of insulin hormone. A relative error of 6% concerning the insulin hormone signal was considered tolerable.

Author contributions

Prof. Hassan Keypour: project supervisor Dr Khadijeh Rabiei: synthesis and identification of materials and participation in the project. Jamal Kouhdareh: PhD student inorganic chemistry, synthesis and identification of materials and participation in the project. Electrochemical analysis Dr Sedigheh Alavinia: synthesis and identification of materials and participation in the project. Dr Rahman Karimi-Nami: consultant in project and data analysis. Dr Shokoufeh Ghahri Saremi: consultant in project and data analysis. Dr Mohammad Noroozi: consultant in project and data analysis.

Conflicts of interest

The authors declare that they have no competing interests.

Acknowledgements

The authors thank the Bu Ali Sina University for supporting this investigation. Any funding source had no role in the design of this study and will not have any role during its execution, analyses, interpretation of the data, or decision to submit results.

References

  1. L. Fotouhi, M. Fatollahzadeh and M. M. Heravi, Electrochemical behavior and voltammetric determination of sulfaguanidine at a glassy carbon electrode modified with a multi-walled carbon nanotube, Int. J. Electrochem. Sci., 2012, 7, 3919–3928 CrossRef CAS .
  2. G. Laputková and J. Sabo, Cyclic voltammetry study of glucose and insulin interactions with supported lipid membrane, Bioelectrochemistry, 2002, 56(1–2), 185–188 CrossRef PubMed .
  3. F. Qu, et al., Amperometric determination of bovine insulin based on synergic action of carbon nanotubes and cobalt hexacyanoferrate nanoparticles stabilized by EDTA, Anal. Bioanal. Chem., 2006, 386(2), 228–234 CrossRef CAS PubMed .
  4. H. Keypour, et al., Electrochemical determination of citalopram on new Schiff base functionalized magnetic Fe3O4 nanoparticle/MWCNTs modified glassy carbon electrode, J. Electroanal. Chem., 2016, 780, 160–168 CrossRef CAS .
  5. C. R. Lowe, Biosensors, Trends Biotechnol., 1984, 2(3), 59–65 CrossRef CAS .
  6. X. Huang, Y. Zhu and E. Kianfar, Nano biosensors: properties, applications and electrochemical techniques, J. Mater. Res. Technol., 2021, 12, 1649–1672 CrossRef CAS .
  7. K. Wu, et al., Direct electrochemistry of DNA, guanine and adenine at a nanostructured film-modified electrode, Anal. Bioanal. Chem., 2003, 376(2), 205–209 CrossRef CAS PubMed .
  8. J. R. Sempionatto, et al., Wearable chemical sensors: emerging systems for on-body analytical chemistry, Anal. Chem., 2019, 92(1), 378–396 CrossRef PubMed .
  9. H. Teymourian, A. Barfidokht and J. Wang, Electrochemical glucose sensors in diabetes management: An updated review (2010–2020), Chem. Soc. Rev., 2020, 49(21), 7671–7709 RSC .
  10. H. Keypour, et al., Post-synthetic modification of dual-porous UMCM-1-NH2 with palladacycle complex as an effective heterogeneous catalyst in Suzuki and Heck coupling reactions, J. Organomet. Chem., 2023, 989, 122646 CrossRef CAS .
  11. H. Keypour, et al., Pd-Coordinated Salinidol-Modified Mixed MOF: An Excellent Active Center for Efficient Nitroarenes Reduction and Selective Oxidation of Alcohols, ACS Omega, 2023, 8(24), 22138–22149 CrossRef CAS PubMed .
  12. K. Rabiei, et al., Palladium Schiff base complex-modified Cu (BDC-NH 2) metal–organic frameworks for C–N coupling, RSC Adv., 2023, 13(12), 8114–8129 RSC .
  13. H. Keypour, et al., Investigation of the electrocatalytic reaction for the oxidation of alcohols through the formation of a metal organic framework (Mn-MIL-100)/polymer matrix on the surface of an Au electrode, New J. Chem., 2023, 47(14), 6730–6738 RSC .
  14. W. Liu and X.-B. Yin, Metal–organic frameworks for electrochemical applications, TrAC, Trends Anal. Chem., 2016, 75, 86–96 CrossRef CAS .
  15. C. Zhang, et al., Immobilization on metal–organic framework engenders high sensitivity for enzymatic electrochemical detection, ACS Appl. Mater. Interfaces, 2017, 9(16), 13831–13836 CrossRef CAS PubMed .
  16. Y. Dong, et al., Preparation of Ag@ zeolitic imidazolate framework-67 at room temperature for electrochemical sensing of hydrogen peroxide, Analyst, 2019, 144(2), 521–529 RSC .
  17. J. Zhang, Y. Tan and W.-J. Song, Zeolitic imidazolate frameworks for use in electrochemical and optical chemical sensing and biosensing: a review, Microchim. Acta, 2020, 187(4), 1–23 Search PubMed .
  18. J. Ding, et al., An electrochemical aptasensor for Pb2+ detection based on metal–organic-framework-derived hybrid carbon, Biosensors, 2020, 11(1), 1 CrossRef PubMed .
  19. J. Kouhdareh, H. Keypour and S. Alavinia, Anchorage of Pd into Modified Isoreticular Metal–Organic Framework-3 as a Heterogeneous Catalyst for Mizoroki–Heck Crosscoupling Reactions, Acta chem. Malays., 2022, 6(1), 35–42 Search PubMed .
  20. J. Pillay, et al., Monolayer-protected clusters of gold nanoparticles: Impacts of stabilizing ligands on the heterogeneous electron transfer dynamics and voltammetric detection, Langmuir, 2010, 26(11), 9061–9068 CrossRef CAS PubMed .
  21. S. Bera, et al., Effect of copolymer chain length and additives on the catalytic efficiency of thermo-sensitive block copolymer stabilized gold nanoparticles, Colloids Surf., A, 2020, 603, 125122 CrossRef CAS .
  22. C. M. Welch and R. G. Compton, The use of nanoparticles in electroanalysis: a review, Anal. Bioanal. Chem., 2006, 384(3), 601–619 CrossRef CAS PubMed .
  23. F. Nie, et al., N-doped 2D graphite-2H nanoplatelets (GNPs) with enhanced PMS activation performance: Structure-dependent performance and Catalytic Mechanism, J. Taiwan Inst. Chem. Eng., 2022, 131, 104158 CrossRef CAS .
  24. Q. Wang, et al., Synthesis and modification of ZIF-8 and its application in drug delivery and tumor therapy, RSC Adv., 2020, 10(62), 37600–37620 RSC .
  25. P. Kukkar, et al., Recent advances in the synthesis techniques for zeolitic imidazolate frameworks and their sensing applications, Coord. Chem. Rev., 2021, 446, 214109 CrossRef CAS .
  26. C. Liu, et al., Controllable synthesis of ultrathin layered transition metal hydroxide/zeolitic imidazolate framework-67 hybrid nanosheets for high-performance supercapacitors, J. Mater. Chem. A, 2021, 9(18), 11201–11209 RSC .
  27. Y. Arafat, et al., Advances in zeolite imidazolate frameworks (ZIFs) derived bifunctional oxygen electrocatalysts and their application in zinc–air batteries, Adv. Energy Mater., 2021, 11(26), 2100514 CrossRef CAS .
  28. V. Stavila, A. A. Talin and M. D. Allendorf, MOF-based electronic and opto-electronic devices, Chem. Soc. Rev., 2014, 43(16), 5994–6010 RSC .
  29. J. M. Goncalves, et al., Recent trends and perspectives in electrochemical sensors based on MOF-derived materials, J. Mater. Chem. C, 2021, 9(28), 8718–8745 RSC .
  30. X. Liu, et al., Recent advances on metal–organic frameworks in the conversion of carbon dioxide, Chin. J. Chem., 2021, 39(2), 440–462 CrossRef CAS .
  31. Y.-R. Lee, et al., ZIF-8: A comparison of synthesis methods, Chem. Eng. J., 2015, 271, 276–280 CrossRef CAS .
  32. Y. Pan, et al., Rapid synthesis of zeolitic imidazolate framework-8 (ZIF-8) nanocrystals in an aqueous system, Chem. Commun., 2011, 47(7), 2071–2073 RSC .
  33. A. A. El-Bindary, et al., Metal–organic frameworks as efficient materials for drug delivery: Synthesis, characterization, antioxidant, anticancer, antibacterial and molecular docking investigation, Appl. Organomet. Chem., 2020, 34(11), e5905 CrossRef CAS .
  34. H. A. Kiwaan, et al., Experimental and electrical studies of zeolitic imidazolate framework-8 for the adsorption of different dyes, J. Mol. Liq., 2021, 338, 116670 CrossRef CAS .
  35. H. A. Kiwaan, et al., Synthesis, identification and application of metal organic framework for removal of industrial cationic dyes, J. Mol. Liq., 2021, 342, 117435 CrossRef CAS .
  36. M. A. El-Bindary, M. G. El-Desouky and A. A. El-Bindary, Metal–organic frameworks encapsulated with an anticancer compound as drug delivery system: Synthesis, characterization, antioxidant, anticancer, antibacterial, and molecular docking investigation, Appl. Organomet. Chem., 2022, 36(5), e6660 CrossRef CAS .
  37. A. A. A. Gaber, S. A. Ahmed and A. M. A. Rahim, Cathodic adsorptive stripping voltammetric determination of Ribavirin in pharmaceutical dosage form, urine and serum, Arabian J. Chem., 2017, 10, S2175–S2181 CrossRef .
  38. Z. Mohammadkhani, et al., Synthesizing and post-synthetically modifying metal-organic frameworks (Co (BDC)-NH2) for carbonylative sonogashira coupling reaction, J. Organomet. Chem., 2023, 999, 122822 CrossRef CAS .
  39. H. Keypour, et al., An Efficient Method for Enhancement in the catalytic activity of Dual-Porous Co (BDC-NH2) MOF Au-Decorated Nanoparticle through Post-Synthetic Modification, J. Organomet. Chem., 2023, 122778 CrossRef CAS .
  40. S. Devi, et al., Highly sensitive and selective detection of trinitrotoluene using cysteine-capped gold nanoparticles, Anal. Methods, 2016, 8(22), 4398–4405 RSC .
  41. J. Liu, et al., NiO-PTA supported on ZIF-8 as a highly effective catalyst for hydrocracking of Jatropha oil, Sci. Rep., 2016, 6(1), 1–11 CrossRef .
  42. L. T. Nguyen, K. L. Ky and T. Nam, A zeolite imidazolate framework ZIF-8 catalyst for friedel-crafts acylation, Chin. J. Catal., 2012, 33(4–6), 688–696 CrossRef CAS .
  43. S. Aleksandra, et al., Controlling ZIF-8 nano and microcrystal formation and reactivity through zinc salts variations, in International Symposium of Metal-Mediated Chemistry, 2013 Search PubMed .
  44. A. Schejn, et al., Controlling ZIF-8 nano-and microcrystal formation and reactivity through zinc salt variations, CrystEngComm, 2014, 16(21), 4493–4500 RSC .
  45. O. A. El-Gammal, et al., Structural characterization and biological activity of a new metal complexes based of Schiff base, J. Mol. Liq., 2021, 330, 115522 CrossRef CAS .
  46. J. Kouhdareh, et al., Pd (II)-immobilized on a novel covalent imine framework (COF-BASU1) as an efficient catalyst for asymmetric Suzuki coupling, J. Mol. Struct., 2023, 1273, 134286 CrossRef CAS .
  47. J. Kouhdareh, et al., Immobilization of Ag and Pd over a novel amide based covalent organic framework (COF-BASU2) as a heterogeneous reusable catalyst to reduce nitroarenes, Inorg. Chim. Acta, 2023, 545, 121251 CrossRef CAS .
  48. S. Zhuang, et al., New nitrogen-doped graphene/MOF-modified catalyst for fuel cell systems, ECS Trans., 2016, 72(8), 149 CrossRef CAS .
  49. H. Keypour, et al., Facile synthesis of a new covalent organic framework (COF-AYLIN) based on polyamide links and their application in CN coupling reaction, Inorg. Chim. Acta, 2023, 552, 121494 CrossRef CAS .
  50. M. J. Schöning and A. Poghossian, Recent advances in biologically sensitive field-effect transistors (BioFETs), Analyst, 2002, 127(9), 1137–1151 RSC .
  51. B. R. Eggins, Chemical sensors and biosensors, John Wiley & Sons, 2002, vol. 2 Search PubMed .
  52. J. Pingarrón, P. Yá nez-Sede no and A. González-Cortés, Electrochim. Acta, 2008, 53, 5848 CrossRef .
  53. Y. Shang, Affinity-based label free immunosensor for detection and quantification of bioanalytes in human clinical samples, PhD thesis, Oakland University[thin space (1/6-em)]ProQuest Dissertations Publishing, 2013, 10586960 .
  54. G. Paimard, M. B. Gholivand and M. Shamsipur, Determination of ganciclovir as an antiviral drug and its interaction with DNA at Fe3O4/carboxylated multi-walled carbon nanotubes modified glassy carbon electrode, Measurement, 2016, 77, 269–277 CrossRef .
  55. E. Laviron, General expression of the linear potential sweep voltammogram in the case of diffusionless electrochemical systems, J. Electroanal. Chem. Interfacial Electrochem., 1979, 101(1), 19–28 CrossRef CAS .
  56. M. Jaafariasl, E. Shams and M. K. Amini, Silica gel modified carbon paste electrode for electrochemical detection of insulin, Electrochim. Acta, 2011, 56(11), 4390–4395 CrossRef CAS .
  57. A. Noorbakhsh and A. I. K. Alnajar, Antifouling properties of reduced graphene oxide nanosheets for highly sensitive determination of insulin, Microchem. J., 2016, 129, 310–317 CrossRef CAS .
  58. Y. Lin, et al., Facile synthesis of nickel hydroxide–graphene nanocomposites for insulin detection with enhanced electro-oxidation properties, RSC Adv., 2014, 4(86), 46208–46213 RSC .
  59. A. Salimi, et al., Highly sensitive sensor for picomolar detection of insulin at physiological pH, using GC electrode modified with guanine and electrodeposited nickel oxide nanoparticles, Biosens. Bioelectron., 2008, 24(4), 792–798 CrossRef CAS PubMed .
  60. A. Salimi, et al., Electrooxidation of insulin at silicon carbide nanoparticles modified glassy carbon electrode, Electrochem. Commun., 2009, 11(6), 1116–1119 CrossRef CAS .
  61. N. Amini, M. B. Gholivand and M. Shamsipur, Electrocatalytic determination of traces of insulin using a novel silica nanoparticles-Nafion modified glassy carbon electrode, J. Electroanal. Chem., 2014, 714, 70–75 CrossRef .
  62. A. Salimi, et al., Picomolar detection of insulin at renewable nickel powder-doped carbon composite electrode, Anal. Chem., 2007, 79(19), 7431–7438 CrossRef CAS PubMed .
  63. J. Wang, et al., Electrocatalytic detection of insulin at RuOx/carbon nanotube-modified carbon electrodes, Anal. Chim. Acta, 2007, 581(1), 1–6 CrossRef CAS PubMed .
  64. A. Arvinte, et al., Electrocatalytic oxidation and determination of insulin at CNT-nickel–cobalt oxide modified electrode, Sens. Actuators, B, 2010, 150(2), 756–763 CrossRef CAS .
  65. B. Rafiee and A. R. Fakhari, Electrocatalytic oxidation and determination of insulin at nickel oxide nanoparticles-multiwalled carbon nanotube modified screen printed electrode, Biosens. Bioelectron., 2013, 46, 130–135 CrossRef CAS PubMed .

This journal is © The Royal Society of Chemistry 2023