Open Access Article
Andreas T.
Güntner‡
*ab and
Florian M.
Schenk‡
c
aHuman-centered Sensing Laboratory, Department of Mechanical and Process Engineering, ETH Zurich, CH-8092 Zurich, Switzerland. E-mail: andregue@ethz.ch
bDepartment of Endocrinology, Diabetology, and Clinical Nutrition, University Hospital Zurich (USZ) and University of Zurich (UZH), CH-8091 Zürich, Switzerland
cParticle Technology Laboratory, Department of Mechanical and Process Engineering, ETH Zurich, CH-8092 Zurich, Switzerland
First published on 26th January 2023
Formaldehyde is a toxic and carcinogenic indoor air pollutant. Promising for its routine detection are gas sensors based on localized surface plasmon resonance (LSPR). Such sensors trace analytes by converting tiny changes in the local dielectric environment into easily readable, optical signals. Yet, this mechanism is inherently non-selective to volatile organic compounds (like formaldehyde) and yields rarely detection limits below parts-per-million concentrations. Here, we reveal that chemical reaction-mediated LSPR with nanohybrids of Ag/AgOx core–shell clusters on TiO2 enables highly selective formaldehyde sensing down to 5 parts-per-billion (ppb). Therein, AgOx is reduced by the formaldehyde to metallic Ag resulting in strong plasmonic signal changes, as measured by UV/Vis spectroscopy and confirmed by X-ray diffraction. This interaction is highly selective to formaldehyde over other aldehydes, alcohols, ketones, aromatic compounds (as confirmed by high-resolution mass spectrometry), inorganics, and quite robust to relative humidity changes. Since this sensor works at room temperature, such LSPR nanohybrids are directly deposited onto flexible wristbands to quantify formaldehyde between 40–500 ppb at 50% RH, even with a widely available smartphone camera (Pearson correlation coefficient r = 0.998). Such chemoresponsive coatings open new avenues for wearable devices in environmental, food, health and occupational safety applications, as demonstrated by an early field test in the pathology of a local hospital.
3 owing to their typically high concentration (i.e. 0.1–10 vol% for H2) and sometimes strong interaction with the corresponding nanoparticle surfaces (e.g. H2 and Pd clusters form PdxHy
4) yielding sufficient sensitivity5 and selectivity.
Yet, the sensing of volatile organic compounds (VOC) by LSRP remains challenging and less established, despite their high relevance for environmental monitoring,6 non-invasive medical diagnostics7 or food quality assessment.8 The VOC are usually detected with conventional LSPR sensors by recognizing variations of the dielectric environment (i.e. refractive index changes) in the vicinity of the plasmonic nanoparticles.9 However, this sensing mechanism is typically unable to (1) detect relevant parts-per-billion (ppb, by volume) concentrations and (2) hardly distinguishes individual VOC, due to their narrow range of refractive index variation.10 For instance, Au metasurfaces decorated with TiO2 nanoparticles enabled the LSPR detection of 1 vol% toluene at room temperature, but this sensor responded to other analytes (e.g. ethanol, acetone) quite similarly, resulting in rather low VOC selectivity.11
Here, we show that a chemical reaction between analyte and plasmonic surface strongly enhances the sensitivity and selectivity of LSPR sensors for individual VOC. This is investigated exemplarily with nanohybrids of Ag/AgOx core–shell structures on TiO2 (Fig. 1a) together with formaldehyde, a carcinogenic air pollutant12 emitted, for instance, from wood-based products,13 coatings or insultation materials with strict exposure limits (e.g. 80 ppb by WHO14). Therein, the AgOx shells (yellow) undergo a redox reaction with formaldehyde vapor at room temperature.15 This reduces the AgOx shells to metallic Ag (black) that exhibits strong plasmonic resonance,16 unlike AgOx, resulting in a detectable optical signal. Note that the redox interaction of Ag+ and aldehydes is known as the Tollens reaction,17 that is established for the detection of aldehydes in liquids.18
Fig. 1d shows the X-ray diffraction (XRD) patterns of such powders. Most importantly, neither Ag (diamonds) nor Ag2O (stars) crystals were detected for up to 10 wt% Ag/AgOx. This confirms the small crystal sizes of Ag, as suggested by STEM-HAADF (Fig. 1b), and thin layer thicknesses of AgOx,20 as well as their amorphous structure. Only above 20 wt% Ag/AgOx, new XRD peaks (e.g. at 2θ = 44.5°) emerge that indicate larger Ag crystals. Note that the characterization of the TiO2 support is provided in the ESI.†
![]() | ||
| Fig. 2 LSPR formaldehyde sensing and mechanism at room temperature. (a) UV/Vis reflectance spectra (solid lines) of 4 wt% Ag/AgOx–TiO2 nanohybrids when exposed to 0–500 ppb formaldehyde at room temperature and 50% RH in air as well as after reducing the nanohybrids in 5 vol% H2 in Ar at 300 °C for 30 min (red, solid line) and subsequent 500 ppb formaldehyde exposure (turquoise, broken line) that overlap. (b) LSPR response (ΔR at λLSPR = 565 nm) as a function of formaldehyde concentration (0–500 ppb). (c) Corresponding XRD patterns before (black), after exposure to 50 ppm formaldehyde (green) in air and after reduction with a H2/Ar mixture at 300 °C (red). Reference peaks for metallic Ag (diamond and dashed line), rutile (squares) and anatase (circles) TiO2 are indicated. Extended XRD patterns for 2θ = 22–44° are provided in ESI Fig. 5.† (d) LSPR response (at λLSPR = 565 nm) of TiO2 with nominal 0–100 wt% Ag to 500 ppb fomaldehyde. Symbols and error bars for 3, 4 and 5 wt% Ag indicate the averages and standard deviations of three identically produced sensors. | ||
The observed LSPR peak suggests the formation of surface metallic Ag through the reduction of AgOx by formaldehyde (Fig. 1a). While isolated Ag nanoparticles exhibit LSPR peaks between 400–450 nm (depending on size22), the red-shift here should be associated9 to the TiO2 support featuring high refractive index (e.g. anatase TiO2n = 2.54 (ref. 23)). A similar observation had been made also when exposing AgOx/Ag clusters on TiO2 to strong UV irradiation16 with application as multicolor photochromic material for smart buildings or displays.24 Consistently, AgOx/Ag on SiO2 with lower refractive index (i.e. n = 1.55 (ref. 23)) featured similar LSPR peak to isolated Ag (i.e. 405 nm, ESI Fig. 4†).
By quantifying the reflectance change at λLSPR (i.e. response ΔR), formaldehyde concentrations are detected over the entire relevant range between 0 and 500 ppb (Fig. 2b), covering typical levels in homes (usually <50 ppb),25 freshly renovated buildings (e.g. 149 ppb for 6000 homes, in China26) and even mobile homes, where formaldehyde concentrations can be above 1000 ppb.27 Such sensors are also quite reproducible (<5% response deviation), as assessed from three identically produced sensors at 500 ppb (error bar in Fig. 2b). Note that these responses are obtained from the UV/Vis spectra after 60 min of formaldehyde exposure. When faster analysis times are required, the time transients for the different concentrations (ESI Fig. 3b†) can be used, as established for chemoresistive sensors.28 In both cases, however, exposure time needs to be known to determine concentration.
Most remarkably, the plasmonic Ag/AgOx core–shell on TiO2 sensor is capable to detect formaldehyde even down to 5 ppb (signal-to-noise ratio >50) with clear discrimination from 0 and 10 ppb. This is sufficiently low to satisfy the WHO guideline (80 ppb (ref. 14)) in residential buildings and meets even strictest limits of 7 and 8 ppb in California29 and France30 (beginning in 2023), respectively. This demonstrates the immediate impact of chemical reaction-mediated LSPR sensing materials, since several orders of magnitude lower detection limits are achieved than those yielded by conventional LSPR based only on refractive index sensing. In fact, similarly prepared flame-made Au-TiO2
11 detected other volatile organic compounds (i.e., ethanol, acetone, toluene) only down to 1 vol% while Au–CuO sensed CO down to 50 ppm.31 The present detector outperforms even other nanoparticle-based sensor types (e.g. electrochemical, chemoresistive, fluorescence, Table 1) that detected formaldehyde down to 10 ppb, but at unrealistic dry conditions.32 In fact, comparable formaldehyde concentrations at relevant RH were only detected when heating the chemoresistive nanoparticles (e.g. 20 ppb with In4Sn3O12 at 250 °C with 50% RH,33 3 ppb with Si/Pd/Pt or Ti-doped SnO2 at 400 °C with 90% RH34) rendering them less suitable for wearable applications.
| Material sensor type | LOQe (RH) [ppb] | RH range | Formaldehyde selectivity | Ref. | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Acetaldehyde | Ethanol | Methanol | Acetone | Benzene | NH3 | CO | H2 | NO2 | ||||
| a Requires UV illumination. b Evaluated at nominal 5 wt% Ag. c Zeolite faujasite Y-type. d Measured at low (but unspecified) RH. Formaldehyde vapor generated through evaporating aqueous solution. e Limit of quantification, i.e. lowest quantified concentration. | ||||||||||||
| Cr-Pdene/C electrochemical | 200 (dry) | Dry | — | High | — | — | — | High | — | — | — | 57 |
| ZIF-7/TiO2achemoresistive | 25 (dry) | Dry | — | 57 | — | — | >1000 | — | >2000 | — | >1000 | 58 |
| MXene/Co3O4chemoresistive | 10 (dry) | 0–97% | — | 11 | — | 6 | 13 | 6 | — | — | — | 32 |
| Ag—In2O3bchemoresistive | 50 (16%) | 16–75% | — | 4 | 6 | >100 | 50 | 40 | — | — | — | 63 |
| Ag-FAUYc colorimetric/fluorescence | 80 | — | 7 | — | — | 3.5 | — | — | — | — | 64 | |
| CdSe/ZnS fluorescence | 500 (dry) | 0–85% | — | High | — | High | — | — | — | — | — | 65 |
| Ni–In2O3/WS2chemoresistive | 50 (dry) | 0–97% | — | 2 | 2.5 | 3 | 6 | 2 | – | – | 3 | 66 |
| Ag/AgOx–TiO2plasmonic | 5 (50%) | 0–90% | 9.2 | 600 | 550 | 140 | >1000 | 130 | 950 | 140 | 90 | This work |
This superior LSPR sensitivity of Ag/AgOx clusters with formaldehyde at room temperature should be attributed to their redox interaction, as shown in Fig. 1a. This is verified by reducing first all surface AgOx to metallic Ag with 5 vol% H2 in Ar at 300 °C (ref. 20) (Fig. 2a, red line) yielding a similar plasmonic hump to Ag/AgOx under formaldehyde exposure (e.g. 500 ppb, dark green line), just more pronounced. Remarkably, this plasmonic hump does not change when exposing it subsequently to 500 ppb formaldehyde (dashed turquoise line that is on top of the red line), due to the already completed reduction to metallic Ag. Therefore, the redox interaction of formaldehyde with Ag/AgOx is indeed responsible for its highly sensitive LSPR sensing.
We investigated this further by XRD of untreated Ag/AgOx–TiO2 (Fig. 2c, black line) and in situ upon exposure to 50 ppm formaldehyde at room temperature (green line). Most importantly, the Ag peak (diamond) at 2θ = 38.1° increases upon exposure to 50 ppm formaldehyde, suggesting the growth of Ag crystals from the AgOx reduction and further verifying our concept (Fig. 1a). Note that this Ag peak overlaps with peaks of anatase TiO2 (i.e., 2θ = 37.7°, circles). However, the TiO2 is not affected by the formaldehyde exposure, as shown in ESI Fig. 5† where neither the anatase (e.g. at 2θ = 25.2°) nor the rutile peaks (2θ = 27.4°) were affected. An even stronger increase in peak intensity at 38.1° (Fig. 2c, red line) was observed after H2 reduction at 300 °C, in agreement with the UV/Vis spectra in Fig. 2a.
Finally, also the effect of Ag/AgOx content on the response to 500 ppb of formaldehyde at room temperature and 50% RH is investigated (Fig. 2d). Thereby, flame-made pure TiO2 features no detectable optical response, as expected. When increasing the Ag/AgOx content to 4 wt%, a response optimum of 0.69 is observed, as expected from the Beer–Lambert law due to stronger plasmonic light absorption with higher Ag/AgOx surface loading. Above 4 wt%, however, the response deteriorates progressively. This can be due to increasing size of Ag/AgOx clusters at higher Ag contents (as with flame-made Ag/AgOx–SiO2
16) featuring reduced catalytic activity,35 a trend observed also for other plasmonic noble metal-based gas sensors (e.g. Au for O2 detection36).
3 for NO2 or Pd70Au30
2 for H2). The sensor's performance is also competitive, if not significantly better, than other nanoparticle-based formaldehyde sensor types that work at room temperature (Table 1). For instance, most of these sensors suffered from rather weak ethanol selectivity (<60), that is particularly problematic given ethanol's omnipresence in cleaning agents or disinfectants,37 requiring their combination, for example, with filters (e.g. molecular sieves38 or sorption columns39).
![]() | ||
Fig. 3 Selectivity to formaldehyde and humidity robustness at room temperature. (a) LSPR response of 4 wt% Ag/AgOx on TiO2 nanohybrids to 500 ppb of various indoor air-relevant gases and vapors at 50% RH in air. (b) Chemical conversion of 1 ppm formaldehyde (circles), methanol (diamonds), ethanol (squares), acetone (triangles) and benzene (stars) at 50% RH over 20 mg of these nanohybrids as a function of temperature. (c) LSPR response to 10 000, 50 000 and 100 000 ppb of methanol, ethanol, CO and H2. The response to 80 ppb formaldehyde (i.e. current WHO guideline14) is shown as dashed line for reference. (d) LSPR response to 500 ppb formaldehyde at various RH. | ||
This formaldehyde selectivity is related to the selective redox interaction of the formaldehyde with the Ag/AgOx clusters (Fig. 2a and c), that is supported further by chemical conversion measurements with high resolution proton transfer reaction time-of-flight mass spectrometry (PTR-TOF-MS, Fig. 3b). In fact, formaldehyde (circles) is fully converted already at room temperature at 50% RH in air, in agreement with literature.15 This confirms the chemical reaction for the sensor–analyte interaction. In contrast, ethanol (squares) requires 60 °C for full conversion while acetone and benzene are not even converted completely at 150 °C, in agreement with the sensor results (Fig. 3a). Note that NH3, CO, H2 and NO2 are not analyzed, as these can hardly be detected by PTR-TOF-MS with H3O+ primary ions.
To challenge the sensor even further, it is exposed to much higher confounder concentrations (10
000–100
000 ppb) of methanol, ethanol, CO, and H2 (Fig. 3c), that can be present in indoor air from cleaning agents,37 combustion sources40 or emitted from humans.41 Remarkably, the sensor is hardly affected and features, at least, three times lower response to these confounders compared to more than three orders of magnitude lower formaldehyde concentrations (i.e. 80 ppb, the WHO limit,14 horizontal dashed line). Thus, the Ag/AgOx–TiO2 sensor is quite robust even to such extreme conditions, where low-cost air quality sensors often fail, as frequently identified as a major challenge by environmental scientists.42 These results highlight the impact of reaction-mediation to render LSPR sensors highly selective and thereby overcome a long-standing limitation for their application to VOC.
Humidity is another challenge for portable formaldehyde sensors that can vary during air quality monitoring. Most importantly, the formaldehyde redox reaction with Ag/AgOx is largely humidity-independent (response variation ± 11%) in the relevant43 range, 25–90% RH, as shown in Fig. 3d. Noteworthy, the Ag/AgOx–TiO2 sensor response nearly doubles from dry to 25% RH suggesting that water vapor plays a significant role in the redox reaction of formaldehyde with Ag/AgOx. This is in agreement with formaldehyde oxidation catalysts (Ag–TiO2
15 and Pt–TiO2
44) at room temperature that increased conversion efficiencies at elevated RH. This was attributed there to increased density of hydroxyl reaction sites.
![]() | ||
| Fig. 4 Sensor integration into wearable device and smartphone read-out. (a) Image of the plasmonic sensing film coated onto a white glass fiber substrate and mounted onto a flexible wristband. The ambient formaldehyde concentration is quantified by a smartphone camera and visualized on a smartphone. (b) Images of these films when exposed to 0, 80 and 500 ppb of formaldehyde at room temperature and 50% RH in air, as well as to the emissions of a dilute formalin solution bath for tissue fixation in the pathology of a local hospital. (c) Color change as quantified by the image processing algorithm in response to 0–500 ppb formaldehyde. The corresponding ideal line (dashed black) and the Pearson correlation coefficient (r) are indicated. The formaldehyde guidelines set by France (8 ppb),30 Canada (40 ppb),67 the WHO (80 ppb),14 the EU workplace limit (300 ppb)68 and the OSHA action level (500 ppb)69 are shown as well. | ||
Fig. 4b shows images of the sensor after exposure to 0, 80 and 500 ppb formaldehyde at 50% RH and room temperature. Remarkably, a color change from beige to brownish is visible even by naked eye already at the WHO limit of 80 ppb that turns to brownish/purple at 500 ppb. This is in agreement with the increasing plasmonic peak between 400 and 700 nm, as observed by UV/Vis reflectance in Fig. 2a. With a smartphone camera, the entire range of relevant formaldehyde concentrations between 40 to 500 ppb is recognized accurately (Fig. 4c). Thereby, the color change ΔE correlates rather linearly (Pearson correlation coefficient r = 0.998) with the formaldehyde concentration. Also, this method is quite reproducible (i.e. ±25% at 80 ppb), that is remarkable considering the application of an ordinary smartphone here.
This sensor can be worn as patch to indicate formaldehyde concentration (and possibly also exposure, if applied as dosimeter) in critical workplaces (e.g. textile and furniture industry, mortuaries, pathology rooms25) to mitigate health risks and improve occupational safety. In fact, an early field test in the pathology of a local hospital demonstrates the recognition of a harmful event under real condition. After 30 min of exposure to the emissions of a diluted formalin solution bath (as typical for tissue fixation), the sensor turned brownish/purple (Fig. 4b). The color change is quite identical to that of 500 ppb of formaldehyde from laboratory standards, that corresponds to the maximum detectable concentration (ESI Fig. 3b†) of this sensor. Simultaneous sampling and off-site analysis measurements by high-resolution proton transfer time-of-flight mass spectrometry quantified the formaldehyde concentration as 10.3 ppm. Note, however, that more validation will be required and we observed some loss of sensing film close to the rim of the glass fiber substrate when the tester moved it to the pathology. While this did not compromise sensor performance, it indicates poor coating stability that needs to be improved.
We envision the use of these Ag/AgOx–TiO2 nanoparticle films also as inexpensive, chemoresponsive paints or coatings, for instance, in “smart” buildings where they can serve as indicators when threshold limits are exceeded (Fig. 4c). Finally, such LPSR sensors are promising also for outdoor applications, where formaldehyde is an increasing concern when emitted at elevated concentrations from “green” fuels49 or wildfires.
In a wider perspective, this work described the next generation of high-performance LSPR sensors that utilize chemical reaction mediation. To date, this concept has been applied only for few inorganic analytes (e.g. H2 with Pd, NO2 with Au). Here, it was shown for a highly relevant VOC that opens new avenues for highly selective and sensitive LSPR sensing in emerging applications like air quality control, health monitoring7 and food safety.6
:
1 (v/v) mixture of acetonitrile (Sigma Aldrich, 99.8%) and 2-ethylhexanoic acid (Sigma Aldrich, 99%) to a total metal content (Ag + Ti) of 0.2 M. For comparison, also Ag/AgOx–SiO2 nanohybrids were made with nominal 4 wt% Ag following the same method. This precursor contained hexamethyldisiloxane (Sigma Aldrich, ≥98%) instead of titanium(IV) isopropoxide, while the rest remained the same.20 These precursor solutions were fed through a capillary at 5 mL min−1 and dispersed with 5 L min−1 oxygen (pressure drop across the nozzle: 1.6 bar). A ring-shaped51 premixed flame of CH4 (1.25 L min−1) and O2 (3.25 L min−1) surrounding the nozzle ignited and sustained the spray flame. Additional 5 L min−1 of sheath O2 supplied through an annulus surrounding the flame ensured excess oxidant.
The particles were deposited for 16 min onto a water-cooled glass fiber filter50 (GF6, Hahnemühle Fineart, 257 mm diameter) at a height of 57 cm above the nozzle aided by a vacuum pump (Seco SV 1025 C, Busch). Sensors were obtained by cutting out 6 mm (diameter) circles of that particle-laden filter with a punching iron (Brütsch, Rüegger & Co.). For some analyses, as specified in the text, powders were obtained by scraping off particles from the filter with a spatula and subsequent sieving (mesh 300 μm, stainless steel) to remove filter fibers. For thermal stabilization and removal of uncombusted precursor, both sensors and powders were annealed at 500 °C for 5 h in an oven (CWF 1300, Carbolite Gero).
The XRD patterns of powders were acquired with a Bruker AXS D8 Advance diffractometer operated at 40 kV and 30 mA (Fig. 1c) or a Bruker D2 Phaser operated at 30 kV and 10 mA (Fig. 2c and ESI Fig. 5†) at 2Θ (Cu Kα) between 20 to 70°. The scanning step size and time were 0.012° and 2.25 s, respectively. Crystal phases were identified by comparison to structural parameters of cubic Ag (PDF 4-784), cubic Ag2O (PDF 75-1532), anatase TiO2 (PDF 21-1272), rutile TiO2 (PDF 21-1276), monoclinic Ti3O5 (PDF 82-1138) and triclinic Ti4O7 (PDF 77-1391). Crystal sizes and weight fractions were approximated by Rietveld refinement with the software Topas 4.2 (Bruker).
The XRD analyses were carried out also immediately after reduction in formaldehyde or H2. Therefore, 20 mg of 4 wt% Ag/AgOx–TiO2 powder was placed in a quartz glass tube and fixed as a packed bed with quartz wool plugs. The formaldehyde reduction was achieved by bubbling 100 ml min−1 dry synthetic air (PanGas 99.999%, CnHm ≤ 0.1 ppm, NOx ≤ 0.1 ppm) through an aqueous formaldehyde solution (0.265 M, yielding a formaldehyde concentration of 50 ppm in its headspace52) and guiding the off-gas through the packed bed for 2 h at room temperature (i.e. 23 °C). The solution was prepared by depolymerizing 0.596 g paraformaldehyde (97%, Sigma Aldrich) in 75 ml H2O, aided by addition of 250 μl KOH (0.1 M, Sigma Aldrich) at 50 °C for 15 min. Reduction by H2
20 was carried out by heating the powder in the quartz glass tube to 300 °C under N2 at 100 ml min−1 and exposing it subsequently to 5 vol% H2 in Ar for 30 min.
The specific surface area (SSA) of powders was determined by nitrogen absorption (Tristar II Plus, Micromeritics) with a Brunauer–Emmett–Teller (BET) five-point method. Prior to measurement, samples were degassed under vacuum for 1 h to remove surface-adsorbed species. Sphere-equivalent diameters were determined from the XRD-derived phase composition using the densities of anatase (3.8 g cm−3), rutile (4.2 g cm−3) and with its nominal content of silver (10.49 g cm−3).
Microscopy was carried out with a FE-SEM 4000 (Hitachi) operated at 12 kV to determine the film morphology and thickness. The film thickness was measured at 16 points around the cut out sensor using the software ImageJ.
For UV/vis experiments, a diffuse reflectance set-up was used, as standard55 for the measurement of such optical properties. Therefore, the sensors were placed inside a Praying Mantis diffuse reflection accessory equipped with a reaction chamber (both Harrick Sci.) and connected to the above gas mixing set-up. The sensors were operated at 31 °C, as measured by a K-type thermocouple. Diffuse reflectance spectra were obtained with a Varian Cary 500 UV/Vis-NIR spectrophotometer (Bruker) between 350 to 700 nm using an averaging time of 2 s and step size of 1 nm. A particle-free glass fibre substrate served as the background. The reflectance difference (ΔR) served as sensor response:56
| ΔR = Ranalyte − Rair |
Early field tests were carried out in the pathology of a local hospital. Before the test, a sensor was stored in synthetic air and at 50% RH. In the pathology, the sensor was placed on a workbench at 20 cm distance from a 4 vol% formalin solution bath for tissue fixation and exposed for 30 min to the surrounding air. For benchmarking, air was sampled simultaneously into Tedlar bags (3 L, SKC Inc.) co-located to the sensor using a pump and analyzed within 2 h by PTR-ToF-MS to prevent analyte loss through the bag wall. Gas samples were diluted with synthetic air at 50% RH to avoid instrument saturation. Note that the Tedlar bags had been cleaned before use by pulling vacuum and filling them with nitrogen (PanGas 99.999%) for three times.62
Footnotes |
| † Electronic supplementary information (ESI) available. See DOI: https://doi.org/10.1039/d2nr06599a |
| ‡ These authors contributed equally. |
| This journal is © The Royal Society of Chemistry 2023 |