Yangju
Lin
and
Stephen L.
Craig
*
Department of Chemistry, Duke University, Durham, North Carolina 27708, USA. E-mail: stephen.craig@duke.edu
First published on 14th September 2020
The mechanical strength of individual polymer chains is believed to underlie a number of performance metrics in bulk materials, including adhesion and fracture toughness. Methods by which the intrinsic molecular strength of the constituents of a given polymeric material might be switched are therefore potentially useful both for applications in which triggered property changes are desirable, and as tests of molecular theories for bulk behaviors. Here we report that the sequential oxidation of sulfide containing polyesters (PE-S) to the corresponding sulfoxide (PE-SO) and then sulfone (PE-SO2) first weakens (sulfoxide), and then enhances (sulfone), the effective mechanical integrity of the polymer backbone; PE-S ∼ PE-SO2 > PE-SO. The relative mechanical strength as a function of oxidation state is revealed through the use of gem-dichlorocyclopropane nonscissile mechanophores as an internal standard, and the observed order agrees well with the reported bond dissociation energies of C–S bonds in each species and with the results of CoGEF modeling.
To this end, we hypothesized that controlling the oxidation of sulfide, which can be conveniently incorporated into polymers, provides an opportunity to achieve oxidative regulation of the mechanical strength of a C–S bond. Relative to polymeric systems that respond to light,4 heat,5 pH,6 force,7 and other stimuli,8–10 polymers whose properties are responsive to oxidation state play remarkable roles in controlled assembly,11 self-healing ability,12 adjusting gel volume,13 and drug delivery.14–16 Construction of such polymers is achieved through incorporation of oxidizable or reduceable (including, in some circumstances, those can be reversibly switched between two oxidation states) chemical functional units, including ferrocene,17 selenide/diselenide,18,19 platinum complexes, sulfide, aryl oxalate esters, phenylboronic esters, thioketals, proline, etc.15 Among these systems, we were drawn to sulfide containing polymers, which are easily constructed through thiol–ene “click” reactions,20 Michael additions,21 ring-opening of ethylene/propylene sulfide22,23 and other scalable and accessible chemistry pathways.24,25 Sulfide-based polymers are further useful in fabricating materials that are capable of adapting nanomorphology,26 changing solubility,27–29 tuning mechanical modulus30 and conductivity,31 and delivering drugs when exposed to oxidants. Generally, the response is triggered by oxidizing sulfide to sulfoxide or sulfone, which is accompanied by a change in dipole moment/hydrophilicity.32
The oxidation to sulfoxide or sulfone affects the C–S bond dissociation energy,33 and we hypothesized that the corresponding mechanical strength (force required for the rapid mechanochemical scission of the corresponding C–S bond) might change similarly. The relative mechanical strengths of sulfide, sulfoxide, and sulfone can be quantified through the use of a nonscissile gem-dichlorocyclopropane (gDCC) mechanophore as an internal standard in pulsed sonication experiments.34 Relative to the conventional single chain-centered mechanophore strategy, for which the main challenge lies in the quantification of mechanophore activation,35 the use of multiple scissile mechanophores and nonscissile internal standards within the same polymer36 enhances the ability to detect differences in reactivity that might not be obvious from, for example, relative rates of chain scission in single-mechanophore polymers.37 As illustrated in Fig. 1, there exists a competition between gDCC ring-opening and C–S bond scission, and the extent to which gDCC ring-opening could occur before chain scission depends on the mechanical strength of C–S bonds. The percentage of gDCC ring opening (gDCC RO%) per chain scission cycle (SC, where SC = ln(M(0)n/M(t)n)/ln2) is characterized by Φ, the slope of gDCC RO% vs. SC, and it indicates the relative mechanical strength of a gDCC containing polymer, i.e., a lower Φ value means a weaker polymer chain. Mechanistic studies have revealed that the use of Φ value accounts for variations in temperature, solvent, concentration, sonication amplitude, etc., but that the initial contour length (Mn) of the polymer does matter, with shorter polymers having higher Φ values (e.g., for a polybutadiene based gDCC polymer, Φ = 0.92 for Mn = 59 kDa vs. Φ = 0.69 for Mn = 92 kDa).35 This quantification strategy has been applied to studies of the relationship between covalent bond strength and mechanical strength,38,39 the mechanochemistry of metallocenes40,41 the chain dynamics of cyclic polymers42 under high strain rate elongational flows, and the subtle influence of stereochemical effects on the mechanical reactivity of Diels–Alder adducts.37
![]() | ||
Scheme 1 Synthesis of sulfide containing polymer and corresponding oxidation of sulfide to sulfoxide and sulfone. |
Obtained polymers were analyzed by GPC (THF mobile phase) coupled with refractive index (RI) and multi-angle light scattering (MALS) detectors. As shown in Fig. 2a, oxidation of PE-S to PE-SO and PE-SO2 leads to a shift in retention time from 13.81 min to 14.06 min, and 13.94 min, respectively. Molecular weights (Mn) determined by MALS are consistent with the shifts in retention time; Mn = 72 kDa for PE-S (ĐM = 1.45), Mn = 54 kDa for PE-SO (ĐM = 1.48), and Mn = 60 kDa for PE-SO2 (ĐM = 1.48). We attribute the reduction in Mn on going from PE-S to PE-SO to low levels of oxidative degradation, and the increase in Mn on subsequent oxidation to PE-SO2 to the addition of O atoms to the polymer chains.
![]() | ||
Fig. 2 (a) Normalized GPC traces (RI signal, THF eluent) of PE-S, PE-SO and PE-SO2. (b) 1H NMR (500 MHz, CDCl3) spectra of PE-S, PE-SO, and PE-SO2. |
The conversion of sulfide to sulfoxide and sulfone is verified by 1H NMR spectroscopy. The protons α and β to the sulfur atom (Ha and Hb, Fig. 2b) begin as clean triplets at 2.84 and 2.67 ppm in PE-S. Upon oxidation, Ha evolves into two coupled multiple peaks at 3.10 and 2.96 ppm, and Hb shifts to 2.91 ppm, which agree well with reported values.45,46 The splitting of Ha is a result of the asymmetry of the sulfoxide, which renders the two Ha protons diastereotopic and magnetically inequivalent. Further oxidation to the symmetric sulfone restores the two triplet peaks, albeit at positions that are further downfield (d = 3.40 ppm and 2.94 ppm).47 Other peaks in the spectra remain effectively unchanged. Integration of Ha/Hb relative to other backbone protons reveals that the molar content of sulfide, sulfoxide, and sulfone stays at a constant value of ∼20 ± 1 mol% (see ESI†), establishing the selective oxidation of sulfide to sulfoxide and sulfone.
Ultrasonication was used to quantify the relative mechanical strength of the polymer as a function of its oxidation state. The Mn of initial PE-S is 72 kDa, which corresponds to a greater contour length than is found in the direct products of its sequential oxidation: PE-SO (Mn = 54 kDa) and PE-SO2 (Mn = 60 kDa). The initial Mn affects the Φ value and therefore complicates a direct comparison of C–S bond strength as a function of oxidation state in cases where a slightly lower Φ value is obtained for a longer polymer. Such is the case when comparing PE-S to PE-SO2 (see above discussion and Fig. S5†), and so we investigated another PE-S polymer with Mn = 60 kDa (ĐM = 1.44) to facilitate the comparison with PE-SO (Mn = 54 kDa) and especially PE-SO2 (Mn = 60 kDa). Results obtained with the 72 kDa parent polymer, however, are consistent with the 60 kDa polymer and show that the variation in mechanical reactivity can be obtained through sequential oxidation within a given polymer. In a typical experiment, a THF solution of the polymer (2 mg mL−1) was treated with pulsed ultrasonication (30% amplitude, 1s on, 1s off, ice bath, N2), with aliquots removed and analyzed periodically until the Mn was reduced to nearly half of its initial value. As the Mn decreased, the extent of gDCC ring opening increased. For example, after subjection of PE-S polymer to ultrasonication for 45 min, the Mn drops from 60 kDa to 36 kDa, and this is accompanied by 29% gDCC ring opening along the polymer backbone (Fig. 3a). Here, polymer chain scission is ascribed to the selective C–S bond cleavage, based on previous evidence that the C–S bond is, mechanically, a relatively weak bond compared with other C–C and C–O bonds along the polymer backbone (also see discussion below).34 The chain scission cycle (SC) is calculated according to the following equation:
The evolution of gDCC RO% vs. SC is shown in Fig. 3b. The Φ value of PE-SO is 0.12, vs. 0.38 for PE-S. Interestingly, increasing the oxidation state further to the corresponding sulfones in PE-SO2 leads to a Φ value of 0.37. The evolution in Φ values suggests that as the sulfide is oxidized to sulfoxide and sulfone, the relative mechanical strength of C–S bonds in each polymer follows the order: PE-S ∼ PE-SO2 > PE-SO. A rough way to evaluate this outcome is comparing the C–S bond dissociation energy (BDE), for the reason that mechanically induced bond cleavage is essentially a force-assisted bond dissociation. Prior work by others suggest that the C–S BDEs of sulfide, sulfoxide, and sulfone are 74–77 kcal mol−1, 53–54 kcal mol−1, and ∼68 kcal mol−1, respectively.33 These BDE values are substantially smaller than those of conventional C–C (>80 kcal mol−1) or C–O (>90 kcal mol−1)48,49 bonds, and indicate that the chain scission preferentially occurs at the C–S bond along the polymer backbone. That the sulfur species are responsible for chain scission is supported by two pieces of evidence. First, a previous study of the polyester obtained from copolymerization of gDCC and glutaric acid showed that Φ = 0.63 for that polymer, even though the polymer in question had a much higher molecular weight (Mn = 140 kDa) and longer contour length than the polymer employed here (higher contour length corresponds to lower Φ).37 Second, CoGEF simulations of extension lead to scission of the C–S bond in all species (see ESI†).
The relative mechanical strength (PE-S ∼ PE-SO2 > PE-SO) is aligned with the BDEs of the various C–S bonds. We computed the relative BDEs of the C–S bonds within the sulfide, sulfoxide and sulfone. The calculation was performed using DFT method on theory level of B3LYP/6-311+G** (details provided in ESI†). As shown in Table 1, the calculated BDEs of C–S bonds follows the order of sulfide > sulfone > sulfoxide, and the relative values agree both with prior work33 and with the relative mechanical strengths inferred from the ultrasonication study. Robb and co-workers50 have recently reported good agreement between the peak force sustained by CoGEF calculations and the propensity of a given bond to break, and a similar trend is observed here (see Table S1, ESI†). In addition, a very recent study by Diesendruck et al.51 on the impact of intramolecular crosslinker on the mechanochemical fragmentation of covalently folded polymers found that the sulfone crosslinkers are slightly more prone to mechanical fragmentation than are sulfide crosslinkers. The results here are consistent with the observations by Diesendruck and co-workers reflecting the intrinsic mechanical strength of the crosslinkers rather than differences in the shape of collapsed chains brought about by the polarity of the sulfone.
C–S bond | Sulfide | Sulfoxide | Sulfone |
---|---|---|---|
BDE (kcal mol−1) | 68 | 46 | 60 |
Footnote |
† Electronic supplementary information (ESI) available. See DOI: 10.1039/d0sc04381h |
This journal is © The Royal Society of Chemistry 2020 |