Open Access Article
This Open Access Article is licensed under a
Creative Commons Attribution 3.0 Unported Licence

One-step synthesis of red-emitting carbon dots via a solvothermal method and its application in the detection of methylene blue

Dan Zhao*, Xuemei Liu, Chunjin Wei, Yimo Qu, Xincai Xiao and Han Cheng
School of Pharmaceutical Science, South-Central University for Nationalities, Wuhan 430074, P. R. China

Received 19th July 2019 , Accepted 2nd September 2019

First published on 18th September 2019


Abstract

The synthesis of carbon dots (CDs) with long wavelengths, particularly the red-emitting ones, has always been the focus of researchers, and a carbon source is critical in this process. In this study, we report the synthesis of red-emitting CDs (CD-tetra) via a one-step solvothermal method with 1,2,4,5-benzenetetramine tetrahydrochloride as a novel carbon source and ethanol as a solvent, and the quantum yield (QY) of CDs is as high as 30.2%. Middle chromatography isolated gel (MCI Gel) column was used to obtain R-CDs, O-CDs and Y-CDs with emission wavelengths at 619, 608 and 554 nm, respectively. It was discovered that these CDs exhibited great differences in their particle sizes and elemental compositions. Moreover, the fluorescence of the CD-tetra could be efficiently quenched using methylene blue (MB). Under optimal conditions, a linear relationship between the decreased fluorescence intensity of the CD-tetra and the concentration of MB was established in the range of 0.05–9.5 μM. The limit of detection (LOD) is 10 nM, suggesting a promising assay for the detection of MB.


1. Introduction

CDs, with their fluorescence capability, are an attractive, carbon-based, functional materials after the appearance of graphene, carbon nanotubes and nanodiamonds,1 and they are widely used in various fields due to their multiple preparation routes, low toxicity, excellent biocompatibility and chemical stability.2 In recent years, the long-wavelength emitting CDs have been the focus of researchers because of their promising potential in cell imaging,3–5 in vivo imaging,6,7 and in vivo labeling and diagnosis.8,9 The reports and papers on green, yellow and orange emitting CDs10–12 have been widely seen in published journals, but the ones on red-emitting CDs13 are relatively scarce.

The selection of proper raw materials is the critical factor that causes the difficulty in the preparation of red-emitting CDs. At present, the raw materials for preparing the red-emitting CDs are mainly two types; one of which is an aromatic compound. Xiong et al.14 prepared red-emitting CDs (λem at 640 and 715 nm) with O-phenylenediamine and glutamic acid as the raw materials, and sulfuric acid as the solvent. This method required a high reaction temperature (210 °C) and a long experimental time (10 h). Zhang et al.15 used phenylenediamine as the raw material and toluene as the solvent to prepare red-emitting CDs. The high toxicity of the solvent toluene greatly limits its expansion for practical applications. The second type is material by doping sulfur/phosphorus. Miao et al.16 prepared red-emitting N, S-CDs via the solvothermal method with citric acid (CA) as the carbon source and thiourea as the sulfur dopant. The maximum emission peak of the as-prepared CDs was at 594 nm. Hu et al.17 mixed CA or ethylene glycol (EG) with ethylenediamine polyethylenimine, and added H3PO4 to prepare the red-emitting CDs. However, the use of multiple types of raw materials, increased variables and complicated synthesis process made this preparation method difficult. The one-step synthesis exhibited its merits (e.g., low-cost and simple process). The solvothermal method is the most advantageous one in preparing the red-emitting CDs.18 Based on this, a new aniline compound was selected as the raw material to realize the fast and simple preparation of red-emitting CDs.

It is worth mentioning that in addition to the preparation, the luminescence mechanism is also an area of focus in CDs research. The multiple synthesis methods for CDs make it difficult to study the synthesis process, and also hinder the progress on the study of their luminescence mechanism. The direct characterization of CDs via their acquired products has been reported in most published literature.19,20 Several researchers have reported their studies on the luminescence mechanism based on the separation of the acquired products.21,22 Ding et al.21 used silica column chromatography to separate the product and acquired CDs with emission wavelengths ranging from 440 nm to 625 nm, and finally proved that the red-shifting of the emission peak was the result of the increase in the degree of surface oxidation.21

Although several high separation efficiency techniques have been reported, these methods exhibit obvious drawbacks. For example, high performance liquid chromatography (HPLC)23,24 and polyacrylamide gel electrophoresis (PAGE)25 require repeated separations to acquire sufficient amounts, and in addition, the separation effect of SiO2 chromatography is not good and the loss is large. In this study, we report the application of MCI Gel as a filler to realize CDs product separation. The MCI Gel is a polystyrene-based, reversed-phase resin filler exhibiting excellent separation efficiency with a large loading amount.

Methylene blue (MB) is a thiazide dye and is widely used as a near-infrared dye. High concentrations of MB can poison animals and cause death. The residues of MB in aquatic products have also received attention, and studies have found that such dyes and metabolites are teratogenic.26,27 It is necessary to detect the content of methylene blue. At present, methods for detecting MB include early spectrophotometry,28 liquid chromatography29,30 and capillary electrophoresis.31 Some of these methods have lower sensitivity and are unsuitable for microanalysis. In addition, some operations can be cumbersome, whereas the spectrophotometric method is simple and rapid, so it is suitable for detecting MB.

This paper reports the preparation of red-emitting CD-tetra via a fast and simple one-step solvothermal route with 1,2,4,5-benzenetetramine tetrahydrochloride as an original carbon source. The QY of the as-prepared CDs is up to 30.2%, and the as-prepared CDs exhibit an excitation wavelength dependent property. To better understand the luminescence mechanisms, the MCI Gel column chromatography was selected to realize the separation of the synthesis product, and the red, orange and yellow-emitting, excitation wavelength independent CDs were finally acquired. Based on these experiments, a reasonable synthesis and luminescence mechanism are proposed. In addition, the fluorescence of the as-prepared CDs is quenched in the presence of MB. Therefore, the as-prepared CDs may work as fluorescent probes for the rapid detection of MB.

2. Experimental section

2.1 Reagents and materials

1,2,4,5-Benzenetetramine tetrahydrochloride (AR, 95%) was acquired from Adamas Reagent Co., Ltd. 1,2,4-Benzenetriamine dihydrochloride (AR, 97%) was purchased from Saan Chemical Technology (Shanghai) Co., Ltd. O-Phenylenediamine (AR, 98%) was obtained from Aladdin Industrial Corporation. Solvents were purchased from Sinopharm Chemical Reagent Co., Ltd., all of which were of AR grade (unless otherwise stated). The MCI Gel filler (CHP20/P120) was purchased from the Mitsubishi Chemical Corporation of Japan, and Rhodamine 6G and Rhodamine B were purchased from Aladdin Chemistry Co., Ltd. NaH2PO4, Na2HPO4, methylene blue, Sudan I (SDI), methyl red (MR), CoCl2, ZnCl2, FeCl3, CaCl2, CuCl2, CdCl2 and HgCl2 were purchased from Sinopharm Chemical Reagent Co., Ltd. (Shanghai, China). Deionized (DI) water was used throughout the experiment.

2.2 Characterization

A LS55 fluorescence spectrophotometer (PerkinElmer) was used to record the fluorescence spectra, and a Lambda-35 UV-Vis spectrophotometer (PerkinElmer) was used to measure the UV-Vis absorption spectra. A Nicolet 6700 Fourier infrared spectrometer (Malvern, UK) was used to record FTIR spectra. A VG Multilab 2000 X-ray photoelectron spectroscopy instrument was used to perform surface analyses and a JEM-2100F transmission electron microscope (Japan Electron Optics Laboratory Company) was used to characterize the surface morphology of the as-prepared CDs. The pH was monitored by a PHSJ-3F pH meter (Shanghai Precision Scientific Instrument Company). X-ray power diffraction (XRD) patterns were recorded on a D8-Advance spectrometer (Bruker, Germany).

2.3 Synthesis of CDs

CDs were synthesized in one step by the solvothermal method. The synthesis procedure is as follows: 0.025 g of 1,2,4-benzenetriamine dihydrochloride powder was dissolved in 24 mL of ethanol and stirred well for 10 min with N2. The mixture was then transferred into a 25 mL Teflon-lined stainless-steel autoclave and kept at 170 °C for 5.5 h. Subsequently, the reaction solution was cooled down. The same reaction conditions and steps were used as described above for O-phenylenediamine and 1,2,4-benzenetriamine dihydrochloride.

2.4 Quantum yield (QY) measurements

Rhodamine 6G (QY = 95%) and Rhodamine B (QY = 56%) dissolved in absolute ethanol (refractive index η = 1.096, 25 °C) were used as references.32 The QY of the CDs was calculated by comparing the ratio of the fluorescence area (Rhodamine 6G-λex = 488 nm and Rhodamine B-λex = 495 nm) to the absorbance. All samples were dissolved in absolute ethanol and their absorbance at 488 nm or 495 nm was controlled to be less than 0.1. The relative QY is calculated using the following equation:
ΦX = ΦST(GradX/GradST)(ηX2/ηST2)
where Φ is QY, Grad is the ratio of the fluorescence area to the absorbance, η is the refractive index of the solvent, ST is the standard substance, and X is the CDs sample, where ηX = ηST.

2.5 Detection of MB

CD-tetra, ethanol and the different detected samples were made up to a final volume of 1 mL, followed by the addition of the MB standard at various concentrations. The fluorescence emission spectra were recorded after a reaction time of 1 min. The selectivity of the MB sensing was confirmed by adding common metal ion stock solutions (including Co2+, Zn2+, Fe3+, Ca2+, Cu2+, Cd2+, and Hg2+ ions) and other dyes (Sudan I and MR) instead of MB and replicating the experimental procedure. The fluorescence was recorded at an excitation wavelength of 540 nm. All experiments were performed at room temperature.

3. Results and discussion

3.1 Synthesis of red-emitting CD-tetra

3.1.1 The effects of the number of amino groups on the anilines. The type of raw material plays a critical role in the CD synthesis. The impact of the number of amino groups on the aniline derivatives upon the as-prepared CDs was investigated. With the other reaction parameters fixed (24 mL absolute ethanol, 170 °C and 5.5 h), three anilines (O-phenylenediamine, 1,2,4-benzenetriamine dihydrochloride and 1,2,4,5-benzenetetramine tetrahydrochloride, 0.025 g) were used to prepare the CDs. The CDs prepared with O-phenylenediamine, 1,2,4-benzenetriamine dihydrochloride and 1,2,4,5-benzenetetramine tetrahydrochloride were named CDs-di, CDs-tri and CDs-tetra, respectively. The excitation and emission wavelengths, QYs and references of the as-prepared CDs are shown in Table 1, and the related calculations for QYs shown in the ESI. The QYs of the three CDs were measured in ethanol (the QY of CD-tetra reached 30.2% (Fig. S1)). In addition, the fluorescence spectrum of the three CDs are shown in Fig. 1, and the photographs of the CD-di, CD-tri and CD-tetra solutions in ambient light (top) and 365 nm UV light (bottom) are shown in the inset (from left to right). With the increased number of amino groups, the excitation and emission wavelengths all exhibited a redshift. Although the emission wavelengths of CD-tri and CD-tetra do not differ by much, the QY of CD-tetra greatly increases, showing that the amino group number plays a critical role in the synthesis process. We speculate that the greater number of amino groups (the active group) on the benzene ring would ensure a large number of active sites during the conjugation reaction, which would be more beneficial to the synthesis of CDs with larger particle sizes and rich nitrogen content. Since the CD-tetra exhibited excellent optical properties, it was thus chosen as the target for further research.
Table 1 The excitation wavelengths, emission wavelengths, QYs and reference of CD-di, CD-tri and CD-tetra
Sample λex/nm λem/nm QY Reference
CDs-di 420 538 16.7% Rhodamine 6G
CDs-tri 510 598 13.4% Rhodamine B
CDs-tetra 540 605 30.2% Rhodamine B



image file: c9ra05570c-f1.tif
Fig. 1 Fluorescence spectra of CD-di, CD-tri and CD-tetra. Inset: Ambient lighting (top) and 365 nm UV lamp (bottom) with CD-di, CD-tri and CD-tetra solutions from left to right.
3.1.2 The impact of the amount of raw materials. The amount of raw materials also has an impact on the optical properties of the as-prepared CDs, and it was thus investigated. With other experimental parameters fixed, as shown in Fig. S2, the increase in the raw material amount (from 0.005 g to 0.025 g) led to a dramatic increase in the fluorescence intensity of the asprepared CDs. Interestingly, the amount of raw materials had a great influence on the fluorescence color and intensity of the CDs, but had little effect on the emission wavelength. From 0.005 g to 0.025 g, the fluorescence intensity gradually increased with an increase in the amount of raw materials, which indicates that the raw material for forming CDs had not reached saturation. However, from 0.025 g to 0.045 g, the amount of raw materials for the reaction saturated. The presence of the raw material that did not participate in the reaction causes a partial fluorescence quenching, resulting in a decrease in the fluorescence intensity. The optimal amount was thus set at 0.025 g.
3.1.3 The impact of temperature and time. The reaction temperature and time are critical factors that impact the optical properties of the as-prepared CDs.33 With other parameters fixed, the impact of the reaction temperature was investigated. The fluorescence increased as the temperature rose from 150 °C to 170 °C, and it decreased when the temperature kept rising to 190 °C (Fig. S3a). Similarly, the fluorescence increased as the time increased from 3.5 to 5.5 h, and decreased when the time increased to 6 h (Fig. S3b). We finally determined the optimal conditions as 170 °C and 5.5 h.

3.2 Separation

Since previous literatures have reported on the luminescence mechanism of CDs through the separation process, the same research was carried out through the separation herein. MCI Gel chromatography was adopted because of its high separation efficiency, easy operation, large sample loading, and environmentally friendly solvents. As shown in Fig. 2, with CD-tetra as the precursor for separation, MCI Gel was pretreated with methanol for 30 min, and then filled into a column for separation (the MCI Gel powder mass at 20 g, filling height at 20 cm, loading product at 0.1 g). Through gradient elution (methanol and water as eluents, methanol 30–100%), red, orange and yellow-emitting CDs were acquired and marked as R-CDs, O-CDs and Y-CDs, respectively. The acquired CD solutions were then dried into solids for characterization.
image file: c9ra05570c-f2.tif
Fig. 2 One-pot synthesis and purification route for CD-tetra. Corresponding PL emission spectra of R-, O- and Y-CDs, with maxima at 619, 608 and 554 nm, respectively.

3.3 Characterization

3.3.1 Fluorescence and UV-Vis spectra. Fluorescence and UV-Vis spectroscopy were used to investigate the optical properties of the acquired CDs before the separation procedure (Fig. 3a). The absorption peak at 210 nm in the UV-Vis spectrum of CD-tetra originates from the inherent state π–π* transition of the aromatic sp2 orbitals (C[double bond, length as m-dash]C and C[double bond, length as m-dash]N); the absorption peak at 270 nm originates from the defect state n–π* transition, which mainly includes the oxygen-containing functional groups C–O and C[double bond, length as m-dash]O; and the peak at 540 nm is usually referred to as the transition of the surface groups. The fluorescence spectrum shows an emission peak at 605 nm under an excitation wavelength of 540 nm. The peak was symmetric with a narrow half bandwidth. The fluorescence intensity increases when the excitation wavelength shifts from 490 nm to 540 nm, and reaches a maximum at 540 nm (Fig. 3b). This shows that CD-tetra exhibited excitation wavelength dependence, where the emission peak redshifts with an increase in the excitation wavelength. We explored the impact of the pH value upon the stability of CD-tetra. The PBS buffer solution was prepared by NaH2PO4 and Na2HPO4. Fig. S4 shows the effect of pH (3–13) on the fluorescence property of CD-tetra. The fluorescence intensity of CD-tetra is strong in the pH range of 3 to 5, and the fluorescence intensity decreases with an increase in the pH value.
image file: c9ra05570c-f3.tif
Fig. 3 (a) UV-Vis spectra and emission spectra of CD-tetra. (b) Emission spectra of CD-tetra excited from 440 nm to 550 nm. (c) UV-Vis spectra and emission spectra of R-CDs. (d) UV-Vis spectrum and emission spectrum of O-CDs. (e) UV-Vis spectrum and emission spectrum of Y-CDs; insets are under ambient lighting (left) and 365 nm UV light (right), and the solvent used for all samples is ethanol.

Fig. 3c, d and e are the fluorescence and UV-Vis spectra of the R-CDs, O-CDs and Y-CDs acquired from the separation of CD-tetra, with optimal excitation wavelengths at 550 nm, 540 nm and 410 nm, and corresponding emission wavelengths at 619 nm, 608 nm and 554 nm, respectively. The UV-Vis spectra of the three CDs exhibit the same absorption peaks at 207 nm and 270 nm, and their maximum absorption peaks at 492, 462 and 414 nm, respectively. Their emission peaks red-shift with the increase in the absorption wavelengths, which might be the reason for their different fluorescence colors. The emission wavelength positions of the R-CDs, O-CDs, and Y-CDs are different and essentially have no excitation wavelength dependence, indicating that the three CDs are more uniform in their optical properties than CD-tetra before separation. We believe that CD-tetra has an excitation wavelength dependence due to a mixture of these three CDs. Different luminescent CDs have different dominances at different excitation wavelengths for the CD-tetra mixture. As the excitation wavelength increases, the CDs with longer emission wavelengths become dominant. Thus, the emission wavelengths redshift as the excitation wavelength increases.

3.3.2 TEM and XRD. Transmission electron microscopy (TEM) was used to study the morphology and particle size of the as-prepared products. As shown in Fig. 4, all three samples show a uniform particle size distribution and most particles are amorphous carbon particles without a crystal lattice structure. The average particle sizes of the R-CDs, O-CDs and Y-CDs are 9.39, 8.60 and 6.50 nm, respectively. The larger particle sizes would lead to a longer emission wavelength, which is one of the reasons for their fluorescence color differences. The XRD patterns of the three CDs (Fig. 4) show a broad peak in the range of 23–26° (2θ), further indicating highly disordered carbon atoms.34,35 This is consistent with the TEM results, in which no discernible lattice structures were observed. However, the peaks of the three CDs are at 23°, 25° and 26° (2θ), and the peak values decrease with the increase in the emission wavelengths.
image file: c9ra05570c-f4.tif
Fig. 4 (a), (b) and (c) are the TEM images of the R-CDs, O-CDs and Y-CDs, respectively. The insets of particle size distribution of R-CDs, O-CDs and Y-CDs are illustrated, respectively.
3.3.3 FTIR spectra. Fourier transform infrared spectroscopy (FTIR) was used to understand the sample components and consequently, their luminescence mechanism. As shown in Fig. 5, the peaks at 1633 cm−1, 1510 cm−1, 1430 cm−1, 1234 cm−1 and 1018 cm−1 show the existence of the C[double bond, length as m-dash]O, C[double bond, length as m-dash]C, C–N[double bond, length as m-dash], C–O and C–N groups, respectively; the peaks at 853 cm−1 and 664 cm−1 show the C–H bending vibration on the benzene ring; the peaks at 2928 cm−1 and 2839 cm−1 show the existence of [double bond, length as m-dash]C–H. In addition, certain differences exist among the spectra. The existence of the N–H group was shown at 3149 cm−1 for R-CDs and O-CDs, but at 3369 cm−1 for Y-CDs. The spectrum of R-CDs shows more groups in the 2500–3500 cm−1 region than those of the other two CDs, illustrating that the rich surface groups are beneficial to the redshift in the CDs emission wavelength. Furthermore, the existence of aromatics rich in amino groups and the hydrophilic groups containing N–H and C–O endow the as-prepared CDs with excellent solubility in water, methanol and ethanol.
image file: c9ra05570c-f5.tif
Fig. 5 FTIR spectra of R-CDs, O-CDs and Y-CDs.
3.3.4 XPS spectrum. X-ray photoelectron spectroscopy (XPS) was used to analyze the elemental components of the as-prepared CD samples. As shown in Fig. S6, the spectra of the three CDs all show characteristic absorption peaks at 285, 399 and 531 eV, illustrating the existence of C1s, N1s and O1s,21 respectively. A comparison of the three spectra shows that the peaks of C1s, N1s and O1s are at the same location (Fig. S7). The band can be differentiated into three peaks that correspond to carbon sp2 (C[double bond, length as m-dash]C, 284.6 eV), carbon sp3 (C–O/C–N, 286.1 eV) and the carbonyl carbon (C[double bond, length as m-dash]O, 287.9 eV). The O1s band has two peaks at 531.6 and 533.0 eV, corresponding C[double bond, length as m-dash]O and C–O groups. The N1s band can be differentiated into three peaks at 398.4, 399.1 and 400.2 eV, representing the pyridine N, amino N and pyrrole N, respectively. These results prove that the as-prepared CDs contain a lot of nitrogen-containing fused ring structures, and the functional groups shown in the XPS spectra are in accordance with those in the FTIR spectrum. It is worth mentioning that although the three CD samples showed the same functional groups in the XPS spectrum, their elemental content differed. As shown in Table 2, from R-CDs, O-CDs to Y-CDs, their oxygen element content gradually decrease with the increase in the emission wavelengths. The R-CDs showed the highest nitrogen content (16.38%) of the three, and the difference in the nitrogen content between the O-CDs and Y-CDs was negligible.
Table 2 XPS elemental analysis results of R-CDs, O-CDs and Y-CDs
Sample C (mol%) O (mol%) N (mol%)
R-CDs 73.18 10.44 16.38
O-CDs 76.16 13.88 9.96
Y-CDs 71.98 18.00 10.02


3.3.5 The synthesis and luminescence mechanism of CDs. Through detailed investigation of the synthesis parameters and the process of separation and characterization, the synthesis and luminescence mechanism of the as-prepared CDs were studied. First, the selection of raw materials plays a critical role in the synthesis, which determines the emission wavelength of the CDs. For instance, Lin et al.32 used solvents to heat treat phenylenediamine with different replacement sites, and acquired three blue, green and red-emitting CDs. In our study, O-phenylenediamine, 1,2,4-benzenetriamine dihydrochloride and 1,2,4,5-benzenetetramine tetrahydrochloride were selected as a carbon source to prepare the CDs. Because 1,2,4,5-benzenetetramine tetrahydrochloride has more amino groups and a high nitrogen content, it therefore tends to produce longer wavelength CDs. The amount of raw materials would also impact the fluorescence property of the as-prepared CDs. Liang et al.36 prepared green, yellow and red-emitting CDs by adjusting the amount of O-phenylenediamine or P-phenylenediamine. In their experiments, the amount of phenylenediamine had a great impact upon the emission wavelength of the as-prepared CDs. In our experiments, the amount of raw material would only influence the fluorescence intensity rather than the emission wavelength of the as-prepared CDs. In addition, the fluorescence intensity of the CDs is also affected by temperature and time. As shown in Fig. 6, under a proper temperature and reaction time, the 1,2,4,5-benzenetetramine tetrahydrochloride and ethanol solution would form the red-emitting CD-tetra through a carbonization and aggregation process. To better understand the luminescence mechanism of the as-prepared CDs, separation was used to analyze the acquired product. With the MCI Gel filler as the stationary phase, and ethanol and water as the mobile phase, the R-CDs, O-CDs and Y-CDs were acquired by gradually reducing the polarity of the mobile phase. The fluorescence spectrum showed that CD-tetra possessed a certain excitation wavelength dependency before separation, but these three acquired CDs did not show such dependency. The reasons for such dependency reported that the CDs itself would emit different colored luminescence under different excitation wavelengths.37 In our study, it was discovered that the dependency of the CD-tetra originates from the various products. In the UV-Vis spectrum, the maximum absorption peaks of the three separated CDs redshift with an increase in the emission peak.
image file: c9ra05570c-f6.tif
Fig. 6 The possible synthesis and luminescence mechanism of CDs.

Three proposed mechanisms have been shown to be reasonable, involving the quantum confinement effect or the conjugated π-domain (determined by the carbon core),32 surface state (determined by the carbon skeleton or the attached chemical groups),38 or the molecular state (determined by the surface or internal fluorescence molecules of CDs).39 Ding et al.21 proved that the surface state is the key factor that determines the fluorescence change rather than the quantum size effect, and the increases in both the carboxyl content and oxidation degree on the CDs surface would cause the redshift of the emission wavelength. The raw materials employed in our synthesis are aromatic compounds with amino groups using ethanol as the solvent. Based on the characterization results from TEM, FTIR and XPS of the separated red, orange and yellow-emitting CDs, it was discovered that the optical properties of the as-prepared CDs are determined by both the quantum size effect and surface state. The emission wavelength of the CDs redshifts with an increase in the CD particle size, and an increase in the elemental nitrogen content would also cause the redshift. Since the R-CDs contain more nitrogen, there would be more amino groups on the surface of those CDs. This leads to a decrease in the energy gap between the highest occupied molecular orbit (HOMO) and lowest unoccupied molecular orbit (LUMO),40 and thus a longer emission wavelength than that of the O-CDs and Y-CDs.

3.4 Fluorescent detection of MB

The PL quenching effect of ions and dyes on CD-tetra was investigated. Different samples, including Co2+, Zn2+, Fe3+, Ca2+, Cu2+, Cd2+, Hg2+, SDI (concentration: 100 μM) and MR (concentration: 50 μM) and MB (concentration: 22.7 μM) were each reacted with a CD-tetra solution. As shown in Fig. S8, the F0/F of CD-tetra could be distinctly quenched only with the addition of MB, and there was a small change in F0/F for the CD-tetra after adding metal ions and other dyes (F0 and F are the fluorescence intensity before and after the addition of detected substances). This result revealed that CD-tetra was selective toward MB over the other metal ions and dyes and could be developed as an efficient fluorescence sensor for MB. Fig. 7 shows the quenching effect of the fluorescence intensity towards MB. The fluorescence intensity of CD-tetra decreases gradually with the increase in the MB concentration. The F0/F values were obtained for CD-tetra treated with a concentration gradient of MB. A good linear correlation (R2 = 0.9968) was exhibited over the concentration range of 0.05–9.5 μM. According to the IUPAC standard, the LOD was taken as 3× standard deviation/slope and was calculated as 10 nM.41 For the fluorescence quenching mechanism, the UV-Vis absorption spectra of MB and the emission spectra of CDs-tetra are compared (Fig. S9). The UV-Vis absorption spectrum of MB shows a broad absorption peak at 434–700 nm, which greatly overlaps with the emission spectra of CD-tetra, which enables the effective screening of emission from CD-tetra by MB. This indicates that the fluorescence of the CD-tetra is quenched by MB due to the internal filtration effect.
image file: c9ra05570c-f7.tif
Fig. 7 Emission spectra of CD-tetra after adding MB (from top to bottom: [MB] = 0, 0.05, 0.498, 0.99, 1.96, 3.38, 4.70, 5.60, 6.90, 8.20, 9.50, 13.0, 22.7, 27.1 μM). Inset: The standard curve of the relationship between F0/F.

4. Conclusions

This study, for the first time, reported the fast and simple synthesis of red-emitting CD-tetra via a one-step solvothermal route with 1,2,4,5-benzenetetramine tetrahydrochloride as the carbon source and absolute ethanol as the solvent. Three aniline compounds with different amino numbers were chosen to prepare the CDs under the same synthesis parameters, and the experiments showed that CD-tetra prepared by 1,2,4,5-benzenetetramine tetrahydrochloride with more amino groups exhibited excellent optical properties. The experiment originated from the variations found in the products. The three separated CD products exhibited obvious differences in their particle sizes and elemental content. Furthermore, CD-tetra could be used as a probe for the fluorescence detection of MB in the range of 0.05–9.5 μM and the LOD of CDs-tetra is 10 nM.

Conflicts of interest

There are no conflicts to declare.

Acknowledgements

This research was supported by the Natural Science Foundation of Hubei Province (2016CFB615) and the South Central University for Nationalities (CZY19029). This work was funded by the Academic Team of the South-Central University for Nationalities (XTZ15013). The research was funded by the China Scholarship Council.

References

  1. P. Miao, K. Han, Y. Tang, B. Wang, T. Lin and W. Cheng, Recent advances in carbon nanodots: synthesis, properties and biomedical applications, Nanoscale, 2015, 7, 1586–1595 RSC.
  2. M. Liu, B. Chen, C. Li and C. Huang, Carbon dots: synthesis, formation mechanism, fluorescence origin and sensing applications, Green Chem., 2019, 21, 449–471 RSC.
  3. Y. Jiao, Y. Gao, Y. Meng, W. Lu, Y. Liu, H. Han, S. Shuang, L. Li and C. Dong, One-step synthesis of label-free ratiometric fluorescence carbon dots for the detection of silver ion and glutathione and cellular imaging application, ACS Appl. Mater. Interfaces, 2019, 11, 16822–16829 CrossRef CAS PubMed.
  4. M. Zhang, R. Su, J. Zhong, L. Fei, W. Cai, Q. Guan, W. J. Li, N. Li, Y. S. Chen, L. L. Cai and Q. Xu, Red/orange dual-emissive carbon dots for pH sensing and cell imaging, Nano Res., 2019, 12, 815–821 CrossRef CAS.
  5. F. Yan, Z. Bai, F. Zu, Y. Zhang, X. Sun, T. Ma and L. Chen, Yellow-emissive carbon dots with a large stokes shift are viable fluorescent probes for detection and cellular imaging of silver ions and glutathione, Microchim. Acta, 2019, 186, 113 CrossRef PubMed.
  6. J. Zhao, F. Li, S. Zhang, Y. An and S. Sun, Preparation of N-doped yellow carbon dots and N, P co-doped red carbon dots for bioimaging and photodynamic therapy of tumor, New J. Chem., 2019, 43, 6332–6342 RSC.
  7. H. Ding, X. Zhou, B. Qin, Z. Zhou and Y. Zhao, Highly fluorescent near-infrared emitting carbon dots derived from lemon juice and its bioimaging application, J. Lumin., 201, 9, 211298–211304 Search PubMed.
  8. Q. Duan, M. Che, S. Hu, H. Zhao, Y. Li, X. Ma, W. Zhang, Y. Zhang and S. Sang, Rapid cancer diagnosis by highly fluorescent carbon nanodots-based imaging, Anal. Bioanal. Chem., 2019, 411, 967–972 CrossRef CAS.
  9. P. Gong, L. Sun, F. Wang, X. Liu, Z. Yan, M. Wang, L. Zhang, Z. Tian, Z. Liu and J. You, Highly fluorescent N-doped carbon dots with two-photon emission for ultrasensitive detection of tumor marker and visual monitor anticancer drug loading and delivery, Chem. Eng. J., 2019, 356, 994–1002 CrossRef CAS.
  10. N. Kaur, V. Sharma, P. Tiwari, A. K. Saini and S. M. Mobin, “Vigna radiata” based green C-dots: photo-triggered theranostics, fluorescent sensor for extracellular and intracellular iron (III) and multicolor live cell imaging probe, Sens. Actuators, B, 2019, 291, 275–286 CrossRef CAS.
  11. K. Jiang, S. Sun, L. Zhang, Y. Wang, C. Cai and H. Lin, Bright-yellow-emissive N-doped carbon dots: preparation, cellular imaging, and bifunctional sensing, ACS Appl. Mater. Interfaces, 2015, 7(41), 23231–23238 CrossRef CAS PubMed.
  12. Y. Jiao, X. Gong, H. Han, Y. Gao, W. Lu, Y. Liu, M. Xian, S. Shuang and C. Dong, Facile synthesis of orange fluorescence carbon dots with excitation independent emission for pH sensing and cellular imaging, Anal. Chim. Acta, 2018, 1042, 125–132 CrossRef CAS PubMed.
  13. Q. Guan, R. Su, M. Zhang, R. Zhang, W. Li, D. Wang, M. Xu, L. Fei and Q. Xu, Highly fluorescent dual-emission red carbon dots and their applications in optoelectronic devices and water detection, New J. Chem., 2019, 43, 3050–3058 RSC.
  14. H. Ding, J. Wei, P. Zhang, Z. Zhou, Q. Gao and H. Xiong, Solvent-Controlled Synthesis of Highly Luminescent Carbon Dots with a Wide Color Gamut and Narrowed Emission Peak Widths, Small, 2018, 14, 1–10 Search PubMed.
  15. T. Zhang, J. Zhu, Y. Zhai, H. Wang, X. Bai, B. Dong, H. Wang and H. Song, A novel mechanism for red emission carbon dots: hydrogen bond dominated molecular states emission, Nanoscale, 2017, 9, 13042–13051 RSC.
  16. X. Miao, X. Yan, D. Qu, D. Li, F. Tao and Z. Sun, Red emissive sulfur, nitrogen codoped carbon dots and their application in ion detection and theraonostics, ACS Appl. Mater. Interfaces, 2017, 9, 18549–18556 CrossRef CAS PubMed.
  17. S. Hu, A. Trinchi, P. Atkin and I. Cole, Tunable photoluminescence across the entire visible spectrum from carbon dots excited by white light, Angew. Chem., Int. Ed., 2015, 54, 2970–2974 CrossRef CAS PubMed.
  18. Y. Wang and A. Hu, Carbon quantum dots: synthesis, properties and applications, J. Mater. Chem. C, 2014, 2, 6921–6939 RSC.
  19. C. Wei, J. Li, X. Xiao, T. Yue and D. Zhao, The one-step preparation of green-emission carbon dots based on the deactivator-reducing reagent synergistic effect and the study on their luminescence mechanism, RSC Adv., 2018, 8, 20016–20024 RSC.
  20. F. Huo, W. Liang, Y. Tang, W. Zhang, X. Liu, D. Pei, H. Wang, W. Jia, P. Jia and F. Yang, Full-color carbon dots with multiple red-emission tuning: on/off sensors, in vitro and in vivo multicolor bioimaging, J. Mater. Sci., 2019, 54, 6815–6825 CrossRef CAS.
  21. H. Ding, S. Yu, J. Wei and H. Xiong, Full-color light-emitting carbon dots with a surface-state-controlled luminescence mechanism, ACS Nano, 2015, 10, 484–491 CrossRef PubMed.
  22. K. Ahmad, A. Pal, U. Pan, A. Chattopadhyay and A. Paul, Synthesis of single-particle level white-light-emitting carbon dots via a one-step microwave method, J. Mater. Chem. C, 2018, 6, 6691–6697 RSC.
  23. X. Gong, Q. Hu, M. Paau, Y. Zhang, L. Zhang, S. Shuang, C. Dong and M. Choi, High-performance liquid chroma-tographic and mass spectrometric analysis of fluorescent carbon nanodots, Talanta, 2014, 129, 529–538 CrossRef CAS PubMed.
  24. X. Gong, Q. Hu, M. Paau, Y. Zhang, S. Shuang, C. Dong and M. Choi, Red-green-blue fluorescent hollow carbon nanoparticles isolated from chromatographic fractions for cellular imaging, Nanoscale, 2014, 6, 8162–8170 RSC.
  25. H. Liu, T. Ye and C. Mao, Fluorescent carbon nanoparticles derived from candle soot, Angew. Chem., Int. Ed., 2007, 119, 6593–6595 CrossRef.
  26. M. Hejtmancik, M. Ryan, J. Toft, R. Persing, P. Kurtz and R. Chhabra, Hematological effects in F344 rats and B6C3F1 mice during the 13–week gavage toxicity study of methylene blue trihydrate, Toxicol. Sci., 2002, 65, 126–134 CrossRef CAS PubMed.
  27. S. Wagner, M. Cifone, H. Murli, R. Dodd and B. Myhr, Mammalian genotoxicity assessment of methylene blue in plasma: implications for virus inactivation, Transfusion, 1995, 35, 407–413 CrossRef CAS PubMed.
  28. A. Disanto and J. Wagner, Pharmacokinetics of highly ionized drugs II: methylene blue-absorption, metabolism, and excretion in man and dog after oral administration, J. Pharm. Sci., 1972, 61, 1086–1090 CrossRef CAS PubMed.
  29. N. Gaudette and J. Lodge, Determination of methylene blue and leucomethylene blue in male and female Fischer 344 rat urine and B6C3F1 mouse urine, J. Anal. Toxicol., 2005, 29, 28–33 CrossRef CAS PubMed.
  30. C. Peter, D. Hongwan, A. Küpfer and B. Lauterburg, Pharma-cokinetics and organ distribution of intravenous and oral methylene blue, Eur. J. Clin. Pharmacol., 2000, 56, 247–250 CrossRef CAS PubMed.
  31. H. Borwitzky, W. Haefeli and J. Burhenne, Analysis of methylene blue in human urine by capillary electrophoresis, J. Chromatogr. B: Anal. Technol. Biomed. Life Sci., 2005, 826, 244–251 CrossRef CAS PubMed.
  32. K. Jiang, S. Sun, L. Zhang, Y. Lu, A. Wu, C. Cai and H. Lin, Red, green, and blue luminescence by carbon dots: full-color emission tuning and multicolor cellular imaging, Angew. Chem., Int. Ed., 2015, 54, 5360–5363 CrossRef CAS PubMed.
  33. D. Chen, H. Gao, X. Chen, G. Fang, S. Yuan and Y. Yuan, Excitation-independent dual-color carbon dots: surface-state controlling and solid-state lighting, ACS Photonics, 2017, 4, 2352–2358 CrossRef CAS.
  34. L. Shen, L. Zhang, M. Chen, X. Chen and J. Wang, The production of pH-sensitive photoluminescent carbon nanoparticles by the carbonization of polyethylenimine and their use for bioimaging, Carbon, 2013, 55, 343–349 CrossRef CAS.
  35. J. Liu, X. Liu, H. Luo and Y. Gao, One-step preparation of nitrogen-doped and surface-passivated carbon quantum dots with high quantum yield and excellent optical properties, RSC Adv., 2014, 4, 7648–7654 RSC.
  36. S. Lin, Y. Cheng, C. Lin, J. Fang, W. Xiang and X. Liang, Carbon nanodots with intense emission from green to red and their multifunctional applications, J. Alloys Compd., 2018, 742, 212–219 CrossRef CAS.
  37. L. Pan, S. Sun, A. Zhang, K. Jiang, L. Zhang, C. Dong and H. Lin, Truly fluorescent excitation-dependent carbon dots and their applications in multicolor cellular imaging and multi-dimensional sensing, Adv. Mater., 2015, 27, 7782–7787 CrossRef CAS PubMed.
  38. M. Liu, L. Yang, R. Li, B. Chen, H. Liu and C. Huang, Large-scale simultaneous synthesis of highly photoluminescent green amorphous carbon nanodots and yellow crystalline graphene quantum dots at room temperature, Green Chem., 2017, 19, 3611–3617 RSC.
  39. J. Schneider, C. Reckmeier, Y. Xiong, M. von Seckendorff, A. Susha, P. Kasaák and A. Rogach, Molecular fluorescence in citric acid-based carbon dots, J. Phys. Chem. C, 2017, 121, 2014–2022 CrossRef CAS.
  40. S. Jin, D. Kim, G. Jun, S. Hong and S. Jeon, Tuning the photoluminescence of graphene quantum dots through the charge transfer effect of functional groups, ACS Nano, 2013, 7, 1239–1245 CrossRef CAS PubMed.
  41. X. Li, S. Zhang, S. Kulinich, Y. Liu and H. Zeng, Engineering surface states of carbon dots to achieve controllable luminescence for solid-luminescent composites and sensitive Be2+ detection, Sci. Rep., 2014, 4, 4976 CrossRef CAS.

Footnote

Electronic supplementary information (ESI) available. See DOI: 10.1039/c9ra05570c

This journal is © The Royal Society of Chemistry 2019