Graphitic-phase carbon nitride-based electrochemiluminescence sensing analyses: recent advances and perspectives

Jingjing Jiang , Xinyi Lin , Dong Ding and Guowang Diao *
School of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou, Jiangsu 225002, P. R. China. E-mail: gwdiao@yzu.edu.cn; Fax: +86-514-87975244; Tel: +86-514-87975436

Received 13th March 2018 , Accepted 17th May 2018

First published on 25th May 2018


Abstract

Graphitic-phase carbon nitride (g-C3N4) materials are important polymeric and metal-free semiconductors, and have attracted extensive attention as emerging electrochemiluminescence (ECL) emitters due to their wonderful optical and electronic properties. The g-C3N4-based ECL sensing analysis, as a research hotspot in analytical chemistry, offers an exquisite pathway to monitor target analytes with the advantages of low background signal, high sensitivity, desirable controllability, and simple instrumentation. Herein, we briefly describe the current research status of g-C3N4-based ECL assays along with versatile signaling strategies, introduce the preparation methods and ECL emission mechanisms of g-C3N4-dependent emitters, summarize their ECL sensing applications from 2012 to now, highlighting with special examples of metal ion and small molecule detection, nucleic acid bioanalysis, immunoassay, protein sensing, and cell-related determination. Finally, the prospects and challenges for future work are also explored to design more advanced ECL biosensors.


image file: c8ra02221f-p1.tif

Jingjing Jiang

Jingjing Jiang is currently working as a lecturer at the School of Chemistry and Chemical Engineering, Yangzhou University, China. She received her BS degree in chemistry from Yangzhou University, China, in 2010 and PhD degree in chemistry from Nanjing University, China, in 2015. Her research interests are focused on the development of electrochemiluminescent and electrochemical biosensors.

image file: c8ra02221f-p2.tif

Xinyi Lin

Xinyi Lin completed her BS degree in pharmaceutical engineering from Yangzhou University, China, in 2016. She is currently pursuing the MS degree at the School of Chemistry and Chemical Engineering, Yangzhou University, China. Her research interests are the preparation of nanomaterials for bioanalyses.

image file: c8ra02221f-p3.tif

Dong Ding

Dong Ding is a graduate student at the School of Chemistry and Chemical Engineering, Yangzhou University, China. He received the BS degree in applied chemistry from Yancheng Teachers University, China, in 2016. The main objects of his research are focused on the construction of ECL biosensors.

image file: c8ra02221f-p4.tif

Guowang Diao

Guowang Diao received his PhD degree in analytical chemistry from Nanjing University, China, in 1997. He joined State University of New York, USA, as a postdoctoral research fellow from 1999 to 2001. He is a professor of Chemistry at Yangzhou University, China, and has published over 160 scientific papers. His research interests include electrochemistry-based sensors, supramolecular self-assembly, and electrochemical energy materials.


1. Introduction

With the increasing detection demand for interesting analytes, tremendous efforts have been devoted to establishing novel and sophisticated sensing techniques in recent years, such as fluorescence, electrochemistry, colorimetry, and electrochemiluminescence (ECL), achieving significant progress in environmental monitoring, food security, and early-stage diagnosis of disease.1–8 Among them, ECL is an electrogenerated chemiluminescence process at electrode surface, in which the excited states of emitters are generated by high-powered electron transfer reactions and then return to the ground state for light emission.9–11 In view of the ingenious technological integration of chemiluminescence and electrochemistry, the designed ECL analysis exhibits extraordinary properties including reduced background interference, high sensitivity, desirable controllability, and low-cost equipment.12–18 For example, free of additional light source can avoid the interference of scattering light and luminescent impurities.19 Furthermore, the utilization of various emitters evidently promotes an intensive evolution for the diversity and sensitivity of ECL devices.20 Based on the universal optical and electric characteristics, some burgeoning fluorescence and photoelectrochemical active materials, especially graphene-like materials, are introduced to develop the advanced ECL detection platforms.21–25

Graphitic-phase carbon nitride (g-C3N4) materials, as the crucial polymeric and metal-free semiconductors with the band gap of 2.7 eV, are mainly composed of carbon and nitrogen atoms and possess 2D graphite-like architectures with the interlamellar spacing of ca. 3.3 nm.26–30 Compared with various structural forms of carbon nitride such as α-C3N4 and β-C3N4, g-C3N4 can be identified as the most stable allotrope under ambient conditions.31,32 As shown in Fig. 1, triazine or tri-s-triazine was considered as the basic structural unit of g-C3N4.33 According to the results of density functional theory, tri-s-triazine based structure exhibited higher thermal and chemical stabilities.34 Owing to the lone electron pairs of nitrogen atoms, large surface defect, and proper band gap, g-C3N4 nanosheets (NTs) have been proved to be the ideal ECL emitters for the construction of sensing devices in comparison with the other carbon materials.35,36 For example, Yan et al. fabricated a solid state ECL platform based on gold nanoparticles (Au NPs) functionalized g-C3N4 hybrids for DNA monitoring.37 However, although some overviews concerning g-C3N4-based sensing applications are reported,38,39 there has not been a special report on the ECL sensing of g-C3N4 until now.


image file: c8ra02221f-f1.tif
Fig. 1 (A) Triazine and (B) tri-s-triazine as the basic structural units of g-C3N4. Reproduced from ref. 34 with permission from The American Chemical Society.

Herein, we give an overview to investigate the recent progresses of g-C3N4-based ECL sensing analyses from 2012 to now. As shown in Fig. 2, this review will introduce the synthesis methods and ECL emission mechanisms of g-C3N4-dependent emitters, summarize their sensing applications with various signal amplification strategies, which represent the significant development in this field. Finally, the unknown territory and challenges for future work are also discussed. We firmly believe that this work will be essential for interested readers to better understand their latest development status and directions.


image file: c8ra02221f-f2.tif
Fig. 2 Overview of g-C3N4-based materials for ECL sensing analysis.

2. The fabrication of g-C3N4 materials

In recent years, several thermal treatments, such as chemical/physical vapor deposition, solid-state reaction, and solvothermal methods, can be used to synthesis g-C3N4 by polymerization of various nitrogen-rich organic precursors (e.g. melamine, dicyandiamide, cyanamide, and urea) due to the strong interaction between their atomic layers.40–43 The common synthesis conditions are performed in closed or semi-closed system for the inhibition of NH3 sublimation during the condensation process. By altering the preparation conditions, g-C3N4 with different condensation degrees are available and possess diverse physicochemical properties.44 However, the fabricated g-C3N4 is generally a bulk material, and the poor dispersion and low surface area largely obstruct its widespread applications in sensing fields. Due to the increasing requirement of the sophisticated ECL devices, various g-C3N4-based micro/nanomaterials with satisfactory water-solubility or augmented surface area (e.g. 2D nanosheets, 1D nanorods/nanowires, and 0D quantum dots (QDs)) have attracted considerable attentions, which can be synthesized through liquid exfoliation, thermal etching, hydrothermal/solvothermal treatments, chemical tailoring, chemical oxidation, and so on.45–48 For example, Ju et al. prepared carbon nitride nanosheets (CNNS) by ultrasonic exfoliation of bulk material in water, and constructed a sensitive sensing platform for ECL detection of DNA sequence.49 Based on the low temperature solid-state approach, Lu et al. used g-C3N4 QDs to develop the resonance energy transfer (RET)-mediated ECL sensor for riboflavin assay.50

To improve the determination sensitivity of constructed sensors, the functionalization of g-C3N4 with noble metal nanoparticles, graphene, or graphene analogues have been proved to show excellent ECL performance.51–53 Using Au NPs-functionalized g-C3N4 NTs as the ECL emitter and useful matrix for the modification of dithiobis-(succinimidyl propionate) (DSP), a desirable ECL sensor was reported for dopamine (DA) detection.54 As shown in Fig. 3, a sandwich structure sensing platform was achieved by the covalent coupling of DA molecule and 3-aminophenylboronic acid functionalized polyaniline (APBA/PANI). Based on the effective PANI-initiated ECL quenching for g-C3N4 NTs, this biosensor exhibited a wide linear response in the range of 0.10 pM to 5.0 nM, as well as high selectivity depended on dual-molecule recognition approach. Furthermore, Chi's group fabricated an ECL sensor for the monitoring of folic acid (FA) using g-C3N4/reduce graphene oxide (RGO) nanohybrid.55 The introduction of RGO with 2D π–π conjugated framework could serve as the buffer layer for over-injected high energy electrons, and led to the stable ECL response with a declining onset potential. Taking advantage of g-C3N4 QDs decorated g-C3N4 NTs, Xu et al. designed a facile ECL sensing strategy for nitrites with a detection limit down to 0.12 μM. Owing to the increased surface defects, the prepared nanohybrids as luminophores exhibited preeminent ECL activities.56


image file: c8ra02221f-f3.tif
Fig. 3 The preparation of DSP-decorated Au–g-C3N4 for highly selective ECL detection of DA based on dual-molecular recognition and PANI quenching. Reproduced from ref. 54 with permission from Elsevier.

3. The g-C3N4-based ECL emission mechanisms and sensing strategies

The emission mechanisms of luminophores are usually ascribed to the annihilation and coreactant mechanisms.57,58 In the former, the oxidized and reduced species are both generated on electrode surface during the potential sweep, and thus collide with each other to initiate ECL emission. In order to maintain the emission efficiency in the annihilation mechanism, the wide potential window and stable radical species are required. In the latter, ECL phenomenon is obtained by a single direction potential scan in the luminophore/coreactant system, in which the formed coreactant intermediate can drive the formation of the excited ECL active material under the electrochemical reduction/oxidation reaction and then the generated luminophores in the excited state return to the ground state to emit light. Compared with the annihilation mechanism, this mechanism resolves the restriction of electrochemical scanning potential range and radical stability. Thus, the improvement of emission efficiency significantly enhances the detection sensitivity in the field of ECL sensors, especially in g-C3N4-based ECL assays.59–62 The coreactant ECL emission mechanism can be divided into “reductive-oxidation” (R-O) ECL and “oxidative-reduction” ECL (O-R) according to the involved oxidation or reduction pathway on modified electrode surface.

In the R-O ECL mode, coreactants such as peroxydisulfate (S2O82−), hydrogen peroxide (H2O2), and dissolved oxygen (O2) have been widely used for the construction of g-C3N4-based cathodic ECL sensors. Using g-C3N4 nanoflake as a perfect example, Chi's group described the corresponding ECL behaviors in the presence of R-O coreactants (S2O82−, H2O2, and O2) (Fig. 4A).63 Their research indicated that the g-C3N4 nanoflake film (NFF) on glassy carbon electrode (GCE) showed the intense non-surface state ECL behaviors, which could be verified by the well overlapping of ECL and fluorescence emission spectra from g-C3N4 versus various wavelengths. As demonstrated in Fig. 4B, when the electron energy of modified electrode raised with cathodic potential polarization, the high-energy electrons were injected into the conduction band (CB) of g-C3N4 NFF to produce radical anions g-C3N4˙ (R1). Meanwhile, the hole donors (i.e. ˙OH and SO4˙) were generated by the electrochemical reduction of the coreactants (R2–R4). After the reaction of the hole donors with g-C3N4˙, the excited state g-C3N4 (g-C3N4*) was formed owing to the depletion of electrons and holes in the CB and valence band (VB) of g-C3N4, respectively (R5–R6), and thus emitted blue light when they returned to their ground states.


image file: c8ra02221f-f4.tif
Fig. 4 (A) The ECL responses of g-C3N4 NFF modified GCE in 0.1 M (a) air-saturated PBS of pH 7.0, nitrogen-saturated PBS of pH 7.0 containing (b) 0.258 mM H2O2 and (c) 0.258 mM K2S2O8, and (B) the cathodic ECL emission mechanism for g-C3N4 NFF/R-O coreactant systems. Reproduced from ref. 63 with permission from The Royal Society of Chemistry.

Alternatively, we can achieve the anodic ECL in “O-R” mode. Using triethanolamine (TEA) as the O-R coreactant, Yuan et al. investigated the anodic ECL property of g-C3N4 modified carbon paste electrode.64 They found that a weak anodic ECL response appeared in phosphate buffer solution, while the obviously increased ECL response was observed in the presence of TEA, demonstrating the important effect of selected coreactant on the anodic ECL response. A possible ECL mechanism was reported for g-C3N4/TEA system. Briefly, the positively charged g-C3N4˙+ might be formed from its electrochemical oxidation when the applied voltage was more positive than the VB of g-C3N4 during the appropriate potential scan. Similarly, TEA was electrochemically oxidized into a radical cation (TEA˙+), and then decomposed to yield a powerful reductive TEA˙ radical, which could react with g-C3N4˙+ to form excited state g-C3N4 (g-C3N4*). After g-C3N4* decayed back to its ground state, the emission light was brightened. Besides, Lei et al. found that triethylamine (Et3N) could also enhance the anodic ECL response of g-C3N4 by means of the similar O-R reaction process.65 The authors pointed out that the Et3N˙ radical was obtained by a proton release from electro-oxidized Et3+. After reacted with g-C3N4˙+, the generated g-C3N4* could trigger a strong anodic ECL signal. Zhu and coworkers developed a feasible label-free ECL aptasensor to detect acetylcholinesterase (AChE) in combination of Au NPs decorated g-C3N4 and TEA as luminophore and anodic coreactant, respectively.66

Since ECL systems are generally involved in four crucial reaction steps (i.e. redox reactions on electrode surface, homogeneous chemical reactions, the generation of excited state species, and light emission),67 the ECL readouts can be regulated effectively by altering (accelerating or inhibiting) the above ECL pathways. Several ECL sensing strategies have been proposed for quantitative assays. For g-C3N4-based emitters, the ECL responses can be controlled by different approaches, including the introduction/separation of ECL emitters (or active species interacted with ECL emitters), the generation/consumption of coreactants, and the steric hindrance caused by the biorecognition reaction, which directly or indirectly impact the reaction microenvironment changes via the interactions between ECL active species and the corresponding recognition events. More interestingly, in comparison with one-signal detection, the emerging dual-signal techniques are more reliable owing to the reduction of positive or negative false signals which are initiated by experimental conditions. Zhang et al. obtained dual-ECL signals of CNNS with the aid of S2O82− and TEA at the cathodic and anodic potentials, respectively.68 They found that the distinct quenching/enhancement effect upon diverse metal ions were realized at various driven potentials, which might result from the difference of energy level matching between CNNS and metal ions (Fig. 5A), as well as the catalytic actions of CNNS˙+ and TEA˙ (Fig. 5B, taking Ni2+ as a model). Thus, a potential-mediated dual-signal ECL sensor was successfully developed with no additional masking reagents and labeling, and the linear response of Ni2+ was calculated from 10 to 120 nM with a detection limit of 2.35 nM (Fig. 5C and D), which could significantly decrease the imperceptible false signal in comparison with the single-ECL analysis previously.


image file: c8ra02221f-f5.tif
Fig. 5 (A) The electronic band structure of CNNS and oxidation/reduction potentials of different metal ions; (B) the proposed ECL reaction pathways of CNNS in the presence of Ni2+; (C) ECL intensity of CNNS-modified GCE with different Ni2+ concentrations in the presence of K2S2O8 at cathodic potential range and TEA at anodic potential range; and (D) the linear fitting of cathodic and anodic ECL quenching coefficients. Reproduced from ref. 68 with permission from The American Chemical Society.

4. Applications of g-C3N4-based ECL sensors

As the electrogenerated chemiluminescence techniques continue to be studied, the g-C3N4-based ECL sensing analyses have grown rapidly, and branched out to the sensitive monitoring of various chemical/biological substances with imperative environmental and clinical significance. Here, in order to summarize their recent advances, this section is divided into five main segments including metal ion and small molecule detection, nucleic acid bioanalysis, immunoassay, protein analysis, and cell-related biosensing.

4.1. Metal ion and small molecule detection

As is known to all, heavy metal pollution with strong toxicity have become one of the most serious issues in our living environments, which is harmful to human health even at trace concentration level.69,70 In view of the strong adsorption capacity of g-C3N4 toward metal ions,71,72 several g-C3N4-depended ECL sensors have been constructed for ongoing analytical requirements. For example, Xiao et al. first presented a cathodic ECL of semiconductor g-C3N4 using K2S2O8 as a coreactant.73 They found that the ECL intensity of g-C3N4 could be efficiently quenched through the electron transfer from g-C3N4˙ to Cu2+, which was ascribed to the redox potential of Cu2+/Cu+ lying between the CB and VB of g-C3N4 (see Fig. 5A). Consequently, a simple Cu2+ ECL sensor was developed with satisfactory linear range and low detection limit of 0.9 nM. Later, Yang's group designed a “signal-off” ECL sensor to selectively and sensitively monitor Cu2+ in the g-C3N4/graphene oxide (GO) hybrid/O2 system.74 In contrast to pure g-C3N4, the utilization of GO not only promoted the ECL recyclability but also achieved 380% increase of detection signal. Interestingly, based on the quenching of g-C3N4 NTs ECL emission by Cu2+ and the chelation of pyrophosphate ion with Cu2+, another sensitive g-C3N4 NTs-based ECL sensor was reported by Chi's group for the assay of pyrophosphate ion in synovial fluid.75 Moreover, Zhang et al. managed to synthesize structure-controllable CNNS for monitoring multiple metal ions.76 As demonstrated in Fig. 6A, the bulk carbon nitride (CN) with different polymerization degree were obtained by changing the reaction temperature from 400 to 650 °C, and denoted as CN-T (T represented reaction temperature). After liquid exfoliation, the CNNS with tunable chemical structures were facilely achieved (Fig. 6C), and showed distinctive ECL responses to several metal ions (Fig. 6D). Thus, the accurate and reliable sensors were constructed due to the selective quenching resulted from electron transfer (or inner filter effect) and enhancement caused by catalytic reaction of CNNS˙+/TEA˙ intermediates. Thus, the developed sensor showed high sensitivity for the monitoring of Ni2+, Cd2+ and Cu2+ with low detection limits of 1, 20, and 250 nM, respectively, and could provide an exciting and ingenious approach for the fabrication of remarkable carbon nitride family-based sensors.
image file: c8ra02221f-f6.tif
Fig. 6 (A) The typical reaction path for the formation of full condensed CN; (B) the process of exfoliating CN-T (T = 400, 450, 500, 550, 600, 650); (C) TEM of (a) CNNS-400, (b) CNNS-500, and (c) CNNS-650. (d) XRD spectra of CNNS-650 and CN-650; and (D) ECL responses of (a) CNNS-500, (b) CNNS-650, and (c) CNNS-400 with various metal-ions at the cathodic potential range. Inset: calibration curves for monitoring (a) Ni2+, (b) Cd2+, and (c) Cu2+. Reproduced from ref. 76 with permission from The American Chemical Society.

The g-C3N4-based ECL sensors were also applied for the small molecules assays.77,78 As shown in Fig. 7, Yuan et al. successfully prepared β-cyclodextrin (β-CD) functionalized g-C3N4 (g-C3N4–CD) as a luminophore, and then interacted with ferrocenecarboxylic acid (Fc-COOH) to form g-C3N4–CD–Fc-COOH inclusion complex via host–guest recognition. After acetylcholinesterase (AChE) was chemically conjugated onto inclusion complex modified electrode, a sensitive “signal-on” ECL sensor was constructed for organophosphate pesticides (OPs) determination.79 In the absence of OPs, the hydrolysis reaction of acetylthiocholine (ATCl) by AChE could in situ produce acetic acid (HAc), which reacted with coreactant Et3N to achieve a low ECL signal. However, the presence of OPs could effectively inhibit AChE activity for the lessened coreactant consumption, resulting in an enhanced ECL response. Recently, Wang et al. constructed an amplified ECL aptasensor for 17β-estradiol (E2) assay using Eu2O3/g-C3N4 nanocomposite as efficient luminophore.80 They found that the ECL intensity of g-C3N4 could be dramatically elevated by Eu2O3 clusters with oxygen vacancies. When the target was captured by E2 aptamer on sensing platform surface, the ECL response would decrease with the increasing E2 concentration due to the steric effect of E2-aptamer complex. Based on this, the designed ECL aptasensor manifested excellent sensitivity and selectivity toward E2. Du and coworkers developed a facile ratiometric ECL sensing for monitoring glucose levels on the basis of in situ production and conversion of coreactants triggered by the catalytic cascade reactions of glucose oxidase-immobilized g-C3N4-supported Au nanocomposites (GOx/Au–g-C3N4) (Fig. 8).81 In the absence of glucose, Au–g-C3N4 provided a stable and strong cathodic ECL using dissolved oxygen as a coreactant. After the addition of glucose, H2O2 was in situ produced by enzyme catalysis, and then converted into reactive oxygen species by Au NPs, leading to a decreased cathodic ECL from g-C3N4 NTs as well as an enhanced anodic ECL from luminol. By means of the competitive oxygen consumption, the designed biosensor exhibited prominent performances (such as wide linear response range, low detection limit, and high selectivity) without additional coreactants for signal amplification.


image file: c8ra02221f-f7.tif
Fig. 7 (A) The synthesis procedure of g-C3N4–CD–Fc-COOH. (B) Schematic diagram of the construction and response mechanism of ECL biosensor for OPs assay. Reproduced from ref. 79 with permission from The Royal Society of Chemistry.

image file: c8ra02221f-f8.tif
Fig. 8 The ratiometric ECL biosensor for glucose detection by means of in situ production and conversion of coreactants caused by catalytic cascade reactions of GOx/Au–g-C3N4. Reproduced from ref. 81 with permission from Elsevier.

4.2. Nucleic acid bioanalysis

Nucleic acids are the messenger of biological genetic information and the foundation of gene expression. With the development and innovation of life science and technology, the ECL behavior of g-C3N4 has been widely used for nucleic acid sensing.82 For example, Shan et al. proposed an ultrasensitive ECL strategy for DNA assay coupling of the conformational conversion of biotinylated capture DNA and the favorable electrocatalytic activity of g-C3N4 NTs@cobalt(II) proto-porphyrin IX (CoPPIX@C3N4) biotag.83 In the presence of target sequence, the hairpin structure of capture DNA were unfolded via biorecognition reaction and exposed the biotinylated 5′ extremity. Then, the streptavidin-functionalized CoPPIX@g-C3N4 was immobilized on electrode interface via biotin–streptavidin linkage, and electrochemically reduced coreactant H2O2 for the significant decrease of ECL response. The designed biosensor could monitor target DNA down to femtomolar concentration and exhibit a wide linear range over 6 orders of magnitude. Xu's group developed a novel dual-wavelength ratiometric ECL biosensor for detecting microRNA via the RET between g-C3N4 nanosheets and Ru(bpy)32+.84 As displayed in Fig. 9, the synthesized Au NPs functionalized g-C3N4 not only favored the modification of thiol-labeled molecular beacon, but also showed a stable ECL emission peak at 460 nm which matched well with the absorption peak of Ru(bpy)32+. The spectral overlap of g-C3N4 NTs with Ru(bpy)32+ gave a strong evidence for the appearance of ECL emission of Ru(bpy)32+ at 620 nm, building a highly efficient ECL-RET system. After target microRNA hybridized with molecular beacon, the formed DNA–RNA duplex was cleaved by duplex-specific nuclease, and released microRNA to initiate the next cycle for signal enhancement. Then, the DNA-Ru(bpy)32+ probe could be captured by the residual single-strand DNA on modified electrode, leading to the decline of ECL response at 460 nm as well as the increase of ECL response at 620 nm. The proposed ECL-RET method opened a new pathway for the further exploitation of dual-wavelength ECL system and exhibited potential abilities in nucleic acids bioassays.
image file: c8ra02221f-f9.tif
Fig. 9 Schematic diagram of a novel dual-wavelength ratiometric ECL-RET biosensor for the detection of microRNA. Reproduced from ref. 84 with permission from The American Chemical Society.

Notably, since the properties of g-C3N4 strongly depend on the synthesis methods, many researches have attempted to exploit new-type g-C3N4 with desired surface modification and functionalization. In this case, Zhang and coworkers reported that mechanical grinding of CN with 1-pyrenebutyrate molecules could realize the interface-modified CNNS (m-CNNS) through noncovalent exfoliation and π–π stacking interactions (Fig. 10A), which not only retained the original ECL properties of CNNS material but also formed a well-assembled interface for further binding various biomolecules, shaking off the deficiencies of carbon nitride in surface science.85 Using probe ssDNA (pDNA) as a model to covalently conjugate m-CNNS modified electrode, an appealing biosensor was constructed for target DNA (tDNA) detection based on the ECL quenching of m-CNNS by Cu2+ obtained from the generation of DNA–Cu2+ complex (Fig. 10B). Instead of covalent linkage with direct physical absorption, only a small increase (9%) was observed by the immobilization of pDNA on conventional CNNS. Thus, this ECL biosensor had enhanced sensitivity in comparison with the physical absorption of DNA probe on unmodified CNNS, and the proposed preparation method of m-CNNS could significantly enlarge their potential application in biosensing.


image file: c8ra02221f-f10.tif
Fig. 10 (A) The general fabrication of m-CNNS based on simultaneous noncovalent modification and exfoliation process, and (B) the construction of ECL DNA biosensor using m-CNNS, and conventional CNNS as a control. Reproduced from ref. 85 with permission from The American Chemical Society.

4.3. Immunoassay

As a fascinating ECL emitter, some functionalized g-C3N4 nanomaterials have been applied in the construction of immunosensor with excellent detection performances. For example, Chen et al. designed an ECL immunosensor to monitor carcinoembryonic antigen (CEA) concentrations based on Au NPs decorated g-C3N4 nanohybrids.86 The introduced gold nanoparticles could effectively suppress the ECL passivation by capturing and storing the partial CB electrons of g-C3N4 NTs, and catalyze the reduction of persulfate (S2O82−) to produce SO4˙ as hole donor, achieving a high and stable cathodic ECL response. The modified electrode was prepared by the stepwise modification of Au NPs functionalized g-C3N4 and CEA antibody (anti-CEA). After CEA was captured, the related electrons transfer and coreactant diffusion was blocked by the steric hindrance of generated protein layers, and thus the ECL response was decreased linearly from 0.02 to 80 ng mL−1. Guo et al. constructed a disposable and label-free ECL immunosensor for the determination of carbohydrate antigen 125 (CA125) on the basis of one-off screen-printed carbon electrodes (SPCEs) and multi-functionalized g-C3N4.87 As shown in Fig. 11, the carboxylated g-C3N4 was sequentially functionalized by the covalent coupling of amino-coated Fe3O4 and CA125 antibody (anti-CA125). The introduction of Fe3O4 nanoparticles was beneficial to the existence of carboxylated g-C3N4 in the outer Helmholtz plane of biosensor and resulted in the enhancement of ECL emission of g-C3N4 through the accelerated electron transport between SPCEs and g-C3N4. After the specific binding with CA125 antibody, CA125 was captured on the sensing system, leading to the obvious inhibition of ECL response. Later, Guo et al. also developed a new potential-resolved “in-electrode” type ECL immunosensor for simultaneous monitoring of CA125 and squamous cell carcinoma antigen (SCCA) using AuNP-functionalized g-C3N4 NTs as cathodic and Ru-NH2 as anodic luminophores.88 In this immunoassay, the CA125 and SCCA were both captured by the corresponding anti-CA1251 and anti-SCCA1, and served as join points to directly assemble the signal tags of (Ru & anti-CA1252)@GO and anti-SCCA2-AuNPs/g-C3N4, which showed two different ECL emissions at 1.25 V and −1.3 V, respectively. Taking advantage of the proposed strategy, the immobilized luminophores near the outer Helmholtz plane were all valid for the relevant electrochemical reactions and then produced enhanced ECL emissions. Thus, the detection limits of this immunosensor could be obtained with 0.4 mU mL−1 for CA125 and 0.33 pg mL−1 for SCCA.
image file: c8ra02221f-f11.tif
Fig. 11 Schematic illustration of (A) the preparation process of multi-functionalized g-C3N4, and (B) the construction of proposed immunosensor for CA125 detection. Reproduced from ref. 87 with permission from Elsevier.

With the help of similar principles, Li and coworkers synthesized the carboxylated g-C3N4/graphene nanohybrids for ECL SCCA monitoring.89 After the deposition of g-C3N4/graphene and covalent binding of anti-SCCA on the electrode surface, SCCA was captured by specific immunoreaction and impeded the diffusion of coreactant toward the electrode surface. Thus, the ECL response decreased linearly with the logarithm of SCCA concentration ranging from 0.025 to 10 ng mL−1. Then, the authors also exploited a quenched immunosensor for the sensitive CEA determination based on Ag nanoparticles functionalized g-C3N4 (Ag@g-C3N4) as a luminophore and ferrocene carboxylic acid-labeled secondary antibody (Fc-COOH@Ab2) as a quencher.90 In comparison with pure g-C3N4, the obtained Ag@g-C3N4 displayed the excellent ECL intensity and satisfactory adsorption ability, which was benefited to the assembly of primary antibody (Ab1). Meanwhile, Au doped mesoporous Al2O3 nanorods were utilized to conjugate more Fc-COOH@Ab2 (Au@Al2O3–Fc-COOH@Ab2). After a sandwich-type immunoreaction, the ECL response decreased evidently with the increasing CEA concentration owing to the remarkable quenching effect of Au@Al2O3–Fc-COOH@Ab2, which was related to the energy transfer from g-C3N4* to ferrocenium along with the inhibition of radical reactions. Xu et al. designed a spatial-resolved ECL ratiometric device for ultrasensitive determination of prostate specific antigen (PSA) on the bipolar electrode (BPE) surface using Au@g-C3N4 nanocomposites and Ru(bpy)32+ as cathodic and anodic emitters, respectively.91 As indicated in Fig. 12, the electroneutrality of BPE ensured the electrically coupled reactions occurred on cathode and anode. Pt–polyamidoamine (PAMAM)–DNAzyme on cathode surface could quench the ECL signal of g-C3N4 via RET, and promote the catalytic reduction of O2. Meanwhile, it would facilitate the ECL reaction of Ru(bpy)32+ at anode with the increased faradaic current flowing, which was initiated by oxygen reduction. Thus, they obtained an “off–on” ECL at cathode by the release of Pt–PAMAM–DNAzyme accompanied with “on–off” ECL at anode. This ratiometric biosensor for sensitive detection of PSA was achieved with a linear range from 0.10 to 200 ng mL−1.


image file: c8ra02221f-f12.tif
Fig. 12 The spatial-resolved ECL ratiometry for sensitive monitoring of PSA based on a closed BPE. Reproduced from ref. 91 with permission from Elsevier.

4.4. Protein analysis

Protein molecules are key substances for composing cells and tissues in the human body, and can be also detected by g-C3N4-based ECL devices.92 For instance, Kim's group deposited target-mediated polyelectrolyte-aptamer multilayer film on the solid-state modified electrode, and developed a smart permeability gate-based ECL aptasensor for bisphenol A (BPA) detection via the regulation of coreactant diffusion rate.93 As shown in Fig. 13A, the negatively charged Au–g-C3N4 was applied onto GCE, and multiple layers of polyethyleneimine (PEI)/polystyrene sulfonate (PSS) were deposited using layer-by-layer method, followed by the assembly of overlayered films containing PEI and BPA aptamer. Upon the addition of BPA, the formed PEI/aptamer films as a gate were destroyed through the specific binding of target molecules, resulting in the increased ECL response. Using the similar approach, they further reported a label-free ECL biosensor for sensitive determination of protease and nuclease based on target-programmable polyelectrolyte films on g-C3N4 modified electrode.94 Moreover, employing phenoxy dextran (DexP)-g-C3N4 as signal probe, Wei et al. constructed a “signal-on” ECL sensing platform for monitoring concanavalin A (Con A).95 As shown in Fig. 13B, the prepared 3D graphene-gold nanoparticles (3D-GR-AuNPs) as an excellent matrix were utilized for GOx assembly, which could specifically recognize target Con A. After interacted with DexP–g-C3N4 by carbohydrate–Con A interaction, an enhanced ECL signal was achieved as the increase of Con A levels in the range of 0.05–100 ng mL−1. Subsequently, on the basis of polyaniline–3,4,9,10–perylenetetracarboxylic acid–DexP conjugate (PANI–PTCA–DexP) as the signal quenching probe, they developed a “signal-off” ECL biosensor for ultrasensitive Con A determination.96 The sensing platform was constructed by the sequential assembly of Ag–g-C3N4, DexP, and GOx. Upon the anchoring of ConA, PANI–PTCA–DexP was bound onto the modified electrode and resulted in a decreased ECL response due to the quenching effect of PANI in Ag–g-C3N4/S2O82− system. Recently, a “signal-on” aptasensor was reported by Chi's group for platelet derived growth factor (PDGF-BB) assay on the basis of g-C3N4 QDs@CNNS with improved ECL activity.97 When Fc-labeled aptamer was attached, the introduced Fc could lessen the ECL signal of g-C3N4 QDs@CNNS at short distance. In the presence of PDGF-BB, the formed PDGF-BB/aptamer hybrid released from the luminophore surface, efficiently recovering the ECL intensity in detection system. And the ECL intensity of biosensor was proportional to PDGF-BB concentration in the range from 0.02 to 80 nM with a detection limit down to nanomole level.
image file: c8ra02221f-f13.tif
Fig. 13 Schematic illustration of (A) the novel permeability gate-mediated ECL aptasensors by means of target-responsive polyelectrolyte-aptamer films (reproduced from ref. 93 with permission from The Royal Society of Chemistry), and (B) the synthetic process of 3D-GR-AuNPs for the preparation of ECL biosensor (reproduced from ref. 95 with permission from Elsevier).

4.5. Cell-related biosensing

Cell is a basic unit of the organism structure and function, and the g-C3N4-based ECL sensing for cell-related bioanalysis has received more attention because of the great significance in human health and life science. For instance, Liu et al. built a ECL biosensor with reusable ability for cancer cells detection and their surface N-glycan evaluation at dual-potential conditions using gold nanoparticles-modified g-C3N4 as cathodic and Ru(phen)32+ as anodic signal probes.98 In this work, the hybridized capture DNA/aptamer duplex DNA was immobilized onto the MoS2 NTs modified electrode, and triggered the intercalation of Ru(phen)32+ in its groove. By the specific interaction between the aptamer and target cells, the duplex DNA were broken into a single-strand DNA and then released the Ru(phen)32+. Meanwhile, a sandwich-type modified electrode was formed by the recognition interaction between mannose and Con A@Au NPs modified g-C3N4 (Con A@Au–C3N4) nanoprobe. Considering the signal ratio of cathodic and anodic ECL, this biosensor showed desirable sensitivity and selectivity, as well as avoided the traditional routing cell counting procedures. Then, Ju's group reported a similar ECL biosensor for ultrasensitive determination of circulating tumor cells (CTCs) and simultaneous evaluation of the relevant glycan expression based on CNNS and luminol-reduced Au NPs (LuAuNPs) (Fig. 14).99 The Au NPs-decorated CNNS (AuNPs@CNNS) were utilized to couple the aptamer for specific conjugation of CTCs, and lectin-functionalized LuAuNPs were used for surface glycans recognition. In the presence of MCF-7 CTCs, the decreased cathodic ECL could be attributed to the CTCs-based steric effect. Meanwhile, the anodic ECL was heightened owing to the decorated luminol molecules. Thus, this ECL biosensor exhibited excellent performance for the sensitive detection of cell with a detection limit down to 2 cells, and was successfully applied for monitoring the variation of glycans on cell surface. Xu's group developed a ratiometric ECL sensing approach for HL-60 cancer cells determination using g-C3N4 NTs and Ag–PAMAM–luminol nanocomposites as ECL emitters.100 DNA functionalized Ag–PAMAM–luminol nanocomposites were prepared to conjugate the aptamers on magnetic bead surfaces. After the addition of HL-60 cells, Ag–PAMAM–luminol nanocomposites could be liberated from magnetic bead, followed by the hybridization of capture DNA on g-C3N4 modified electrode, which not only quenched the cathodic ECL of g-C3N4 owing to the RET originated from Ag NPs but also increased the anodic ECL of luminol, achieving an obvious ratio change.
image file: c8ra02221f-f14.tif
Fig. 14 The construction of a dual-potential ratiometric ECL biosensor for the monitoring CTCs and evaluating their surface glycan. Reproduced from ref. 99 with permission from Elsevier.

5. Conclusion and future perspectives

In this review, we have detailed the current status of g-C3N4 based-ECL sensing analyses and their special applications with representative examples. Unlike the chromatographic and spectroscopic equipment, g-C3N4-based ECL sensors can be easily utilized to sensitively and selectively monitor various targets including metal ions, small molecules, nucleic acids, antigens, proteins, and cells, with the features of simple instrumentation, low cost, weak background, and desirable controllability, which provide the endless driving forces for their further developments.

In-depth understanding of the signal response strategies of g-C3N4 materials is beneficial to the design of next-generation ECL biosensors. However, the researches of g-C3N4-based sensors are entering a new stage of development and facing some important issues and challenges. We believe that the future work will focus on the improvement of g-C3N4-based ECL detection performance through the following points. Firstly, further investigate the ECL behaviors of new carbon nitride emitters (e.g. g-C3N4 QDs, single layer or chemically modified g-C3N4 NTs) and select these g-C3N4 materials with higher ECL activities. Secondly, combine g-C3N4 materials with new nanomaterials and biomaterials for superior sensing or biosensing. For example, dope with foreign atoms to tune the bandgap of g-C3N4 materials and increase light absorption, or hybridize with other nanomaterials to obtain an enhanced ECL response. Thirdly, by integration of several emerging techniques, the great progress and major technological breakthrough can be achieved in the near future. For example, using the g-C3N4 NTs modified microwell array, a novel ECL imaging strategy was proposed to simultaneously analyze total cholesterol at single cells with better visible sensitivity.101 Fourthly, since most ECL sensors are only able to quantify one analyte, additional works will establish simultaneous or multiplex assay systems. Fifthly, construct reliable sensing systems for the sensitive detection of analytes in complex biological matrixes (e.g. blood, saliva, and urine). Thus, with the continual achievement of above demands, we envision that the developed g-C3N4-based ECL sensors can simultaneously detect different targets in complex samples using simple, rapid, and miniaturized devices, and bring tremendous influences in disease diagnosis, environmental monitoring, and biological detection.

Conflicts of interest

There are no conflicts to declare.

Acknowledgements

We gratefully acknowledge the National Natural Science Foundation of China (No. 21703199, 21773203, and 21511140282), Jiangsu Planned Projects for Postdoctoral Research Funds (No. 1601138C), and a project funded by the Priority Academic Program Development of Jiangsu Higher Education Institutions.

Notes and references

  1. H. S. Jung, P. Verwilst, W. Y. Kim and J. S. Kim, Chem. Soc. Rev., 2016, 45, 1242–1256 RSC.
  2. Q. F. Zhai, X. W. Zhang, Y. C. Han, J. F. Zhai, J. Li and E. K. Wang, Anal. Chem., 2016, 88, 945–951 CrossRef PubMed.
  3. L. Krejcovaa, L. Richtera, D. Hynek, J. Labuda and V. Adama, Biosens. Bioelectron., 2017, 97, 384–399 CrossRef PubMed.
  4. M. H. Xiang, J. W. Liu, N. Li, H. Tang, R. Q. Yu and J. H. Jiang, Nanoscale, 2016, 8, 4727–4732 RSC.
  5. T. Y. Ma, Y. H. Tang, S. Dai and S. Z. Qiao, Small, 2014, 12, 2382–2389 CrossRef PubMed.
  6. Y. Q. Yu, H. Y. Zhang, Y. Q. Chai, R. Yuan and Y. Zhou, Biosens. Bioelectron., 2016, 85, 8–15 CrossRef PubMed.
  7. S. Su, X. Y. Han, Z. W. Lu, W. Liu, D. Zhu, J. Chao, C. H. Fan, L. H. Wang, S. P. Song, L. X. Weng and L. H. Wang, ACS Appl. Mater. Interfaces, 2017, 9, 12773–12781 Search PubMed.
  8. W. Cai, S. B. Xie, J. Zhang, D. Y. Tang and Y. Tang, Biosens. Bioelectron., 2017, 98, 466–472 CrossRef PubMed.
  9. M. M. Richter, Chem. Rev., 2004, 104, 3003–3036 CrossRef PubMed.
  10. J. Q. Liu, X. X. He, K. M. Wang, D. G. He, Y. H. Wang, Y. F. Mao, H. Shi and L. Wen, Biosens. Bioelectron., 2015, 70, 54–60 CrossRef PubMed.
  11. W. W. Zhao, J. Wang, Y. C. Zhu, J. J. Xu and H. Y. Chen, Anal. Chem., 2015, 87, 9520–9531 CrossRef PubMed.
  12. P. Zhang, Z. Y. Li, H. J. Wang, Y. Zhuo, R. Yuan and Y. Q. Chai, Nanoscale, 2017, 9, 2310–2316 RSC.
  13. C. Y. Xiong, W. B. Liang, H. J. Wang, Y. N. Zheng, Y. Zhuo, Y. Q. Chai and R. Yuan, Chem. Commun., 2016, 52, 5589–5592 RSC.
  14. X. Zhang and S. N. Ding, Biosens. Bioelectron., 2017, 94, 47–55 CrossRef PubMed.
  15. X. J. Chen, Y. He, Y. Y. Zhang, M. L. Liu, Y. Liu and J. H. Li, Nanoscale, 2014, 6, 11196–11203 RSC.
  16. Y. F. Wei, H. Wang, S. J. Sun, L. F. Tang, Y. P. Cao and B. Y. Deng, Biosens. Bioelectron., 2016, 86, 714–719 CrossRef PubMed.
  17. H. M. Chen, Q. Y. Lu, J. Y. Liao, R. Yuan and S. H. Chen, Chem. Commun., 2016, 52, 7276–7279 RSC.
  18. L. Y. Zhang, D. Lia, W. L. Meng, Q. Huang, Y. Su, L. H. Wang, S. P. Song and C. H. Fan, Biosens. Bioelectron., 2009, 25, 368–372 CrossRef PubMed.
  19. W. J. Zhu, C. Wang, X. J. Li, M. Saddam Khan, X. Sun, H. M. Ma, D. W. Fan and Q. Wei, Biosens. Bioelectron., 2017, 97, 115–121 CrossRef PubMed.
  20. Y. Chen, S. W. Zhou, L. L. Li and J. J. Zhu, Nano Today, 2017, 12, 98–115 CrossRef.
  21. X. M. Fu, Z. C. Gu, Q. Y. Lu, J. Y. Liao and S. H. Chen, RSC Adv., 2016, 6, 13217–13223 RSC.
  22. Q. Liu, C. Ma, X. P. Liu, Y. P. Wei, C. J. Mao and J. J. Zhu, Biosens. Bioelectron., 2017, 92, 273–279 CrossRef PubMed.
  23. M. Zhao, A. Y. Chen, D. Huang, Y. Q. Chai, Y. Zhuo and R. Yuan, Anal. Chem., 2017, 89, 8335–8342 CrossRef PubMed.
  24. X. Ou, X. R. Tan, X. F. Liu, H. M. Chen, Y. Fan, S. H. Chen and S. P. Wei, RSC Adv., 2015, 5, 66409–66415 RSC.
  25. X. Lin, S. Zhu, Q. H. Wang, Q. Xia, P. Y. Ran and Y. Z. Fu, Colloids Surf., B, 2016, 148, 371–376 CrossRef PubMed.
  26. D. Masih, Y. Y. Ma and S. Rohani, Appl. Catal., B, 2017, 206, 556–588 CrossRef.
  27. C. G. Gomez, A. M. Silva, M. C. Strumia, L. B. Avalle and M. I. Rojas, Nanoscale, 2017, 9, 11170–11179 RSC.
  28. X. C. Wang, K. Maeda, A. Thomas, K. Takanabe, G. Xin, J. M. Carlsson, K. Domen and M. Antonietti, Nat. Mater., 2009, 8, 76–80 CrossRef PubMed.
  29. M. Groenewolt and M. Antonietti, Adv. Mater., 2005, 17, 1789–1792 CrossRef.
  30. E. Z. Lee, Y. S. Jun, W. H. Hong, A. Thomas and M. M. Jin, Angew. Chem., Int. Ed., 2010, 49, 9706–9710 CrossRef PubMed.
  31. X. C. Wang, X. F. Chen, A. Thomas, X. Z. Fu and M. Antonietti, Adv. Mater., 2009, 21, 1609–1612 CrossRef.
  32. G. Mamba and A. K. Mishra, Appl. Catal., B, 2016, 198, 347–377 CrossRef.
  33. A. Thomas, A. Fischer, F. Goettmann, M. Antonietti, J. O. Muller, R. Schlogl and J. M. Carlsson, J. Mater. Chem., 2008, 18, 4893–4908 RSC.
  34. W. J. Ong, L. L. Tan, Y. H. Ng, S. T. Yong and S. P. Chai, Chem. Rev., 2016, 116, 7159–7329 CrossRef PubMed.
  35. Y. Wang, X. C. Wang and M. Antonietti, Angew. Chem., Int. Ed., 2012, 51, 68–89 CrossRef PubMed.
  36. Y. Q. Dong, Q. Wang, H. S. Wu, Y. M. Chen, C. H. Lu, Y. W. Chi and H. H. Yang, Small, 2016, 12, 5376–5393 CrossRef PubMed.
  37. Y. H. Wang, L. N. Zhang, L. Shen, S. G. Ge, J. H. Yu and M. Yan, Microchim. Acta, 2017, 184, 2587–2596 CrossRef.
  38. Q. F. Zhai, J. Li and E. K. Wang, ChemElectroChem, 2017, 4, 1639–1650 CrossRef.
  39. M. Y. Xiong, Q. M. Rong, H. M. Meng and X. B. Zhang, Biosens. Bioelectron., 2017, 89, 212–223 CrossRef PubMed.
  40. L. C. Chen and J. B. Song, Adv. Funct. Mater., 2017, 27, 1702695 CrossRef.
  41. K. S. Lakhi, D. H. Park, K. Al-Bahily, W. Cha, B. Viswanathan, J. H. Choy and A. Vinous, Chem. Soc. Rev., 2017, 46, 72–101 RSC.
  42. Q. Zhao, W. X. Wu, X. Y. Wei, S. L. Jiang, T. Zhou, Q. Li and Q. Lu, Sens. Actuators, B, 2017, 248, 673–681 CrossRef.
  43. B. K. Shrestha, R. Ahmad, S. Shrestha, C. H. Park and C. S. Kim, Biosens. Bioelectron., 2017, 94, 686–693 CrossRef PubMed.
  44. Y. P. Sun, W. Ha, J. Chen, H. Y. Qi and Y. P. Shi, Trends Anal. Chem., 2016, 84, 12–21 CrossRef.
  45. A. J. Wang, H. Li, H. Huang, Z. S. Qian and J. J. Feng, J. Mater. Chem. C, 2016, 4, 8146–8160 RSC.
  46. A. W. Wang, C. D. Wang, L. Fu, W. N. Wong-Ng and Y. C. Lan, Nano-Micro Lett., 2017, 9, 47 CrossRef.
  47. Z. X. Zhou, Y. F. Shen, Y. Li, A. R. Liu, S. Q. Liu and Y. J. Zhang, ACS Nano, 2015, 9, 12480–12487 CrossRef PubMed.
  48. S. B. Yang, Y. J. Gong, J. S. Zhang, L. Zhan, L. L. Ma, Z. Y. Fang, R. Vajtai, X. C. Wang and P. M. Ajayan, Adv. Mater., 2013, 25, 2452–2456 CrossRef PubMed.
  49. Y. Q. Feng, Q. B. Wang, J. P. Lei and H. X. Ju, Biosens. Bioelectron., 2015, 73, 7–12 CrossRef PubMed.
  50. H. Wang, Q. Ma, Y. F. Wang, C. H. Wang, D. D. Qin, D. L. Shan, J. Chen and X. Q. Lu, Anal. Chim. Acta, 2017, 973, 34–42 CrossRef PubMed.
  51. T. Q. Han, X. J. Li, Y. Y. Li, W. Cao, B. Du and Q. Wei, Sens. Actuators, B, 2014, 205, 176–183 CrossRef.
  52. B. Y. Xia, Q. M. Yuan, M. F. Chu, S. F. Wang, R. Gao, S. L. Yang, C. B. Liu and S. L. Luo, Sens. Actuators, B, 2016, 228, 565–572 CrossRef.
  53. L. Y. Hu, J. Zheng, K. Zhao, A. P. Deng and J. G. Li, Biosens. Bioelectron., 2018, 101, 260–267 CrossRef PubMed.
  54. F. M. Zuo, L. Jin, X. M. Fu, H. Zhang, R. Yuan and S. H. Chen, Sens. Actuators, B, 2017, 244, 282–289 CrossRef.
  55. C. Zhou, Y. M. Chen, P. X. Shang and Y. W. Chi, Analyst, 2016, 141, 3379–3388 RSC.
  56. X. Zhu, F. X. Kou, H. F. Xu and G. D. Yang, RSC Adv., 2016, 6, 105331–105337 RSC.
  57. K. Muzyka, Biosens. Bioelectron., 2014, 54, 393–407 CrossRef PubMed.
  58. N. Hao and K. Wang, Anal. Bioanal. Chem., 2016, 408, 7035–7048 CrossRef PubMed.
  59. Z. Y. Liu, W. J. Qi and G. B. Xu, Chem. Soc. Rev., 2015, 44, 3117–3142 RSC.
  60. H. M. Chen, X. R. Tan, J. J. Zhang, Q. Y. Lu, X. Ou, Y. Ruo and S. H. Chen, RSC Adv., 2014, 4, 61759–61766 RSC.
  61. S. D. Xie, F. Wang, Z. Y. Wu, L. Joshi and Y. Liu, RSC Adv., 2016, 6, 32804–32810 RSC.
  62. Y. Zhang, L. N. Zhang, Q. K. Kong, S. G. Ge, M. Yan and J. H. Yu, Anal. Bioanal. Chem., 2016, 408, 7181–7191 CrossRef PubMed.
  63. L. C. Chen, D. J. Huang, S. Y. Ren, T. Q. Dong, Y. W. Chi and G. N. Chen, Nanoscale, 2013, 5, 225–230 RSC.
  64. C. M. Cheng, Y. Huang, J. Wang, B. Z. Zheng, H. Y. Yuan and D. Xiao, Anal. Chem., 2013, 85, 2601–2605 CrossRef PubMed.
  65. Y. T. Liu, Q. B. Wang, J. P. Lei, Q. Hao, W. Wang and H. X. Ju, Talanta, 2014, 122, 130–134 CrossRef PubMed.
  66. Q. Liu, Y. J. Peng, J. C. Xu, C. Ma, L. L. Li, C. J. Mao and J. J. Zhu, ChemElectroChem, 2017, 4, 1768–1774 CrossRef.
  67. W. J. Miao, Chem. Rev., 2008, 108, 2506–2553 CrossRef PubMed.
  68. Q. W. Shang, Z. X. Zhou, Y. F. Shen, Y. Y. Zhang, Y. Li, S. Q. Liu and Y. J. Zhang, ACS Appl. Mater. Interfaces, 2015, 7, 23672–23678 Search PubMed.
  69. B. Bansod, T. Kumar, R. Thakur, S. Rana and I. Singh, Biosens. Bioelectron., 2017, 94, 443–455 CrossRef PubMed.
  70. P. Wu, T. Zhao, S. L. Wang and X. D. Hou, Nanoscale, 2014, 6, 43–64 RSC.
  71. X. F. Chen, J. S. Zhang, X. Z. Fu, M. Antonietti and X. C. Wang, J. Am. Chem. Soc., 2009, 131, 11658–11659 CrossRef PubMed.
  72. N. Y. Cheng, P. Jiang, Q. Liu, J. Q. Tian, A. M. Asiri and X. P. Sun, Analyst, 2014, 139, 5065–5068 RSC.
  73. C. M. Cheng, Y. Huang, X. Q. Tian, B. Z. Zheng, Y. Li, H. Y. Yuan, D. Xiao, S. P. Xie and M. M. F. Choi, Anal. Chem., 2012, 84, 4754–4759 CrossRef PubMed.
  74. B. Y. Xia, M. F. Chu, S. F. Wang, W. Q. Wang, S. L. Yang, C. B. Liu and S. L. Luo, Anal. Chim. Acta, 2015, 891, 113–119 CrossRef PubMed.
  75. H. F. Xu, X. Zhu, Y. Q. Dong, H. S. Wu, Y. M. Chen and Y. W. Chi, Sens. Actuators, B, 2016, 236, 8–15 CrossRef.
  76. Z. X. Zhou, Q. W. Shang, Y. F. Shen, L. Q. Zhang, Y. Y. Zhang, Y. Q. Lv, Y. Li, S. Q. Liu and Y. J. Zhang, Anal. Chem., 2016, 88, 6004–6010 CrossRef PubMed.
  77. S. H. Chen, A. M. Li, L. Z. Zhang and J. M. Gong, Anal. Chim. Acta, 2015, 896, 68–77 CrossRef PubMed.
  78. Y. Fan, X. R. Tan, X. F. Liu, X. Ou, S. H. Chen and S. P. Wei, Electrochim. Acta, 2015, 180, 471–478 CrossRef.
  79. B. X. Wang, H. J. Wang, X. Zhong, Y. Q. Chai, S. H. Chen and R. Yuan, Chem. Commun., 2016, 52, 5049–5052 RSC.
  80. X. J. Du, D. Jiang, L. M. Dai, W. R. Zhu, X. D. Yang, N. Hao and K. Wang, Anal. Chem., 2018, 90, 3615–3620 CrossRef PubMed.
  81. J. J. Jiang, D. Chen and X. Z. Du, Sens. Actuators, B, 2017, 251, 256–263 CrossRef.
  82. P. A. Rasheed, T. Radhakrishnan, S. R. Nambiar, R. T. Thomas and N. Sandhyarani, Sens. Actuators, B, 2017, 250, 162–168 CrossRef.
  83. S. Y. Deng, P. X. Yuan, X. B. Ji, D. Shan and X. J. Zhang, ACS Appl. Mater. Interfaces, 2015, 7, 543–552 Search PubMed.
  84. Q. M. Feng, Y. Z. Shen, M. X. Li, Z. L. Zhang, W. Zhao, J. J. Xu and H. Y. Chen, Anal. Chem., 2016, 88, 937–944 CrossRef PubMed.
  85. J. J. Ji, J. Wen, Y. F. Shen, Y. Q. Lv, Y. L. Chen, S. Q. Liu, H. B. Ma and Y. J. Zhang, J. Am. Chem. Soc., 2017, 139, 11698–11701 CrossRef PubMed.
  86. L. C. Chen, X. T. Zeng, P. Si, Y. M. Chen, Y. W. Chi, D. H. Kim and G. N. Chen, Anal. Chem., 2014, 86, 4188–4195 CrossRef PubMed.
  87. L. Wu, Y. H. Sha, W. R. Li, S. Wang, Z. Y. Guo, J. Zhou, X. R. Su and X. H. Jiang, Sens. Actuators, B, 2016, 226, 62–68 CrossRef.
  88. Z. Y. Guo, L. Wu, Y. F. Hu, S. Wang and X. Li, Biosens. Bioelectron., 2017, 95, 27–33 CrossRef PubMed.
  89. X. J. Li, X. Y. Zhang, H. M. Ma, D. Wu, Y. Zhang, B. Du and Q. Wei, Biosens. Bioelectron., 2014, 55, 330–336 CrossRef PubMed.
  90. X. J. Li, Z. K. Guo, J. X. Li, Y. Zhang, H. M. Ma, X. H. Pang, B. Du and Q. Wei, Anal. Chim. Acta, 2015, 854, 40–46 CrossRef PubMed.
  91. Y. Z. Wang, W. Zhao, P. P. Dai, H. J. Lu, J. J. Xu, J. Pan and H. Y. Chen, Biosens. Bioelectron., 2016, 86, 683–689 CrossRef PubMed.
  92. X. J. Li, H. M. Ma, Y. Zhang, D. Wu, X. H. Lv, B. Du and Q. Wei, Analyst, 2015, 140, 8172–8176 RSC.
  93. L. C. Chen, X. T. Zeng, A. R. Ferhan, Y. W. Chi, D. H. Kim and G. N. Chen, Chem. Commun., 2015, 51, 1035–1038 RSC.
  94. L. C. Chen, X. T. Zeng, A. Dandapat, Y. W. Chi and D. Kim, Anal. Chem., 2015, 87, 8851–8857 CrossRef PubMed.
  95. X. Ou, X. R. Tan, X. F. Liu, Q. Y. Lu, S. H. Chen and S. P. Wei, Biosens. Bioelectron., 2015, 70, 89–97 CrossRef PubMed.
  96. Y. Fan, X. R. Tan, X. Ou, Q. Y. Lu, S. H. Chen and S. P. Wei, Electrochim. Acta, 2016, 202, 90–99 CrossRef.
  97. H. F. Xu, S. J. Liang, X. Zhu, X. Q. Wu, Y. Q. Dong, H. S. Wu, W. X. Zhang and Y. W. Chi, Biosens. Bioelectron., 2017, 92, 695–701 CrossRef PubMed.
  98. Y. He, J. H. Li and Y. Liu, Anal. Chem., 2015, 87, 9777–9785 CrossRef PubMed.
  99. Y. Q. Feng, F. Sun, L. Z. Chen, J. P. Lei and H. X. Ju, J. Electroanal. Chem., 2016, 781, 48–55 CrossRef.
  100. Y. Z. Wang, N. Hao, Q. M. Feng, H. W. Shi, J. J. Xu and H. Y. Chen, Biosens. Bioelectron., 2016, 77, 76–82 CrossRef PubMed.
  101. J. J. Xu, D. P. Jiang, Y. L. Qin, J. Xia, D. C. Jiang and H. Y. Chen, Anal. Chem., 2017, 89, 2216–2220 CrossRef PubMed.

This journal is © The Royal Society of Chemistry 2018