Open Access Article
This Open Access Article is licensed under a Creative Commons Attribution-Non Commercial 3.0 Unported Licence

On–off–on fluorescent oligomer as a chemosensor for the detection of manganese(VII), sulfur(II) and aldehydes based on the inner filter effect

Peng Dingab, Xia Xin*ac, Lingli Zhaoa, Zengchun Xiea, Qinghong Zhangab, Jianmei Jiaoa and Guiying Xuac
aNational Engineering Technology Research Center for Colloidal Materials, Shandong University, Jinan, 250100, P. R. China. E-mail: xinx@sdu.edu.cn; Fax: +86-531-88361008; Tel: +86-531-88363597
bChina Research Institute of Daily Chemical Industry, Taiyuan, Shanxi 030001, P. R. China
cKey Laboratory of Colloid and Interface Chemistry (Shandong University), Ministry of Education, Jinan, 250100, P. R. China

Received 21st October 2016 , Accepted 30th November 2016

First published on 13th January 2017


Abstract

In this article, a sensitive and selective on–off–on fluorescence chemosensor, Tyloxapol (one kind of water soluble oligomer), was developed for the label-free detection of MnO4 ions in aqueous solution. From fluorescence experiments, it is demonstrated that Tyloxapol is a sensitive and selective fluorescence sensor for the detection of MnO4 directly in water over a wide range of anions including Cl, Br, I, NO3, H2PO4, HCO3, OH, ClO4, Ac, SO42−, HPO42−, CO32−, C2O42−, S2−, SO32−, and Cr2O72−. Moreover, the fluorescence intensity of Tyloxapol has shown a linear response to MnO4 in the concentration range of 0 to 120 μmol L−1 with a detection limit of 0.392 μmol L−1 MnO4. The interaction mechanism demonstrated that our on–off fluorescent oligomer probe for detecting Mn(VII) is based on the inner filter effect (IFE) because the absorption bands of Mn(VII) are fully covered by the excitation bands of Tyloxapol. Next, another turn-on sensing application of the Tyloxapol/MnO4 platform to probe S2− against various other anions and aldehydes against various other organic pollutants were also established. It is expected that our strategy may offer a new approach for developing a simple, cost-effective, rapid and sensitive sensor for the detection of anions and aldehydes in environmental applications.


Introduction

Anions widely exist in nature and living organisms, are closely related to human survival and development, and play an important role in medicine, catalysis, environmental science and other fields.1–3 Due to the importance of anions in pharmacy and biological science, the design and synthesis of efficient anion receptors has attracted the intensive interest of scientists.4,5 Compared with cations, anions have their own features, such as the radius of an anion is larger than a cation that has the same charge, the electrostatic attraction between a probe molecule and an anion is weaker than that between a probe molecule and a cation; an anion has a different geometry and the solvent effect has a great influence on the binding properties and selectivity of the anion; an anion is sensitive to the pH of solution, so the detection of anions must occur under a suitable pH environment.6–8

Due to the development of industry, industrial and other anthropogenic processes have been releasing heavy-metal ions into the environment, such as Cr and Mn.9–11 Among them, Mn(VII) is more hazardous to public health compared to other valence states, such as Mn(II) and Mn(VI), because of its greater stability and carcinogenic properties. For example, as for anion pollutants, MnO4 is the most commonly used strong oxidant in both laboratory and industrial applications and MnO4 has received great attention because it can cause severe damage to human health and the environment, which is a worldwide problem that is listed as a priority by the U.S. Environmental Protection Agency.12,13 Therefore, the determination of Mn(VII) in environmental samples is of great importance.14,15 There are many methods to detect MnO4, such as flame atomic absorption spectrophotometry and potassium periodate spectrophotometry, and the detection limit of luminescent probes to detect MnO4 could low as 0.28 μM.16

Moreover, aldehydes are widely used industrial raw material, mainly used in wood industry, textile industry, pesticides, dyes, etc. Formaldehyde is a strong pungent smell of gas, will bring great harm to the human body.17 The main harm of formaldehyde is the stimulation of the skin and mucous membranes. When it reach a certain concentration in room can make people feel uncomfortable, identified as first class of carcinogens in 2006. So the determination of aldehyde in environmental samples is of great importance.18,19 Different kinds of gas sensing approaches have been used to measure aldehyde concentrations in air: such as cataluminescence,20 gas chromatography,21 chemoresistivity (inorganic,22 organic,23 and hybrid24 materials), chemocapacitance,25 bio-sensing,26 amperometric electrochemical cells,27 etc.

Besides, sulfur dioxide (SO2) and its derivatives has vastly produced by the combustion of coal and fuels, exposure to SO2 not only creates breathing problems but also and induce respiratory diseases, even if cancers.28,29 Sulfur ions can exist stable in neutral and alkaline aqueous solution, but it can easily become to hydrogen sulfide under acidic conditions via chemical reaction. Hydrogen sulfide is an extremely malodorous toxic and corrosive gas, which can lead to olfactory fatigue, resulting in the loss of the sense of the sulfide smell.30,31 Once water containing concentration which is higher than 0.5–1 mg L−1 can poison fish. Nevertheless, the design of suitable fluorescent probe for sulfur and sulfate are also challenging. A variety of detection techniques have been developed for the determination of sulfide anion,32 such as titration,33 spectrophotometry,34 inductively coupled plasma atomic emission spectroscopy (ICP-AES),35 electrochemical methods,36 fluorimetry37 and chemiluminescence methods38 and the detection limit of S2− and formaldehyde can low as 0.48 μM (ref. 39) and 36 μM (ref. 40) in the reported article, respectively.

Thus, it can be seen that until now, there are many methods for the detection of MnO4, S2− and formaldehyde as mentioned above, however, these methods are time-consuming and the equipment requirements are high which can't meet the needs of the current analysis. Compared with these conventional methods, fluorescence (FL) detection has been widely used as a versatile tool in analytical chemistry, biochemistry and cell biology due to its high sensibility, specificity, and real-time monitoring with fast response time.41–44 Thus, in this article, a highly sensitive and selective on–off–on fluorescence chemosensor, Tyloxapol (one kind of water soluble oligomer), was developed for the detection of MnO4 and S2− in aqueous solution. Moreover, it can also be used to probe aldehydes against various other organic pollutants. Thus, it is expected that our system can be used as a promising sensor for MnO4, S2− and aldehydes that appear as pollutants in the environment.

Experimental section

Chemicals and materials

Tyloxapol, were purchased from Sigma-Aldrich. The chemical structure of Tyloxapol was shown in Fig. 1. All the metal salts used in this work including NaCl, NaBr, NaI, NaNO3, NaH2PO4, NaHCO3, NaClO4, NaAc, Na2SO4, Na2HPO4, Na2CO3, Na2C2O4, Na2S, Na2SO3, K2Cr2O7, KMnO4 and other organics such as aniline, phenol, formaldehyde, glyoxal were all purchased from Sinopharm Chemical Reagent Co. All the above reagents were used without further purification. Ultra-pure water used in the experiments was triply distilled by a quartz water purification system. Its conductivity was lower than 1.8 μS cm−1 as measured by a DDSJ-308A type conductivity instrument in our laboratory.
image file: c6ra25583c-f1.tif
Fig. 1 The chemical structure of Tyloxapol.

Methods and characterizations

The FL measurements were performed on a LS-55 spectrofluorometer (PerkinElmer, Waltham, MA, USA) with a quartz cell (1 × 1 cm). For transmission electron microscopy (TEM) observations, about 5 μL of solution was placed on a TEM grid and the excess solution was wicked away with filter paper. The copper grid was freeze-dried and observed on a JEOL JEM-100 CXII (Japan) at an accelerating voltage of 80 kV. The quantum yield and fluorescence lifetimes were measured on a FLS920 with a time correlated single photon counting (TCSPC) method by excitation with 360 nm. The absolute fluorescence quantum yields were measured with an integrating sphere. The fluorescence lifetimes were measured on a FLS920 with a time correlated single photon counting (TCSPC) method by excitation with 360 nm. The data were deconvoluted with the instrument response function, recorded using dispersed light, and fitted to a multi-exponential function. The absolute fluorescence quantum yields were measured with an integrating sphere.

Detection of MnO4

In a typical assay, Tyloxapol solution was added into ultra-pure water (the final concentration of Tyloxapol was fixed at 3 mmol L−1), followed by the addition of different concentrations of MnO4 ion. The FL spectra were recorded after reaction for 30 min. The selectivity for MnO4 was confirmed by adding other anions stock solutions instead of MnO4 in a similar way. All experiments were performed at room temperature.

Detection of S2−

In a typical assay, Tyloxapol and MnO4 ion solutions were added into ultra-pure water (the final concentration of Tyloxapol and MnO4 were fixed at 3 mmol L−1 and 200 μmol L−1), respectively, followed by the addition of S2−. The FL spectra were recorded after reaction for 30 min. The selectivity for S2− was confirmed by adding other related anions instead of S2− in a similar way. All experiments were performed at room temperature.

Detection of aldehydes

Tyloxapol and MnO4 ion solutions were added into ultra-pure water (the final concentration of Tyloxapol and MnO4 were fixed at 3 mmol L−1 and 200 μmol L−1), respectively, followed by the addition of formaldehyde. The FL spectra were recorded after reaction for 30 min. The selectivity for formaldehyde was confirmed by adding other organic pollutant. All experiments were performed at room temperature.

Results and discussion

The fluorescent property of Tyloxapol

It is well-known that Tyloxapol can be considered as an oligomer of the nonionic surfactant TX-100 with a polymerization degree below 7.45 In our previous experiment, it has been demonstrated that Tyloxapol has a luminescent property while for TX-100 aqueous solution, no FL has been detected.46 Thus, it can be concluded that the FL of Tyloxapol is ascribed to the close packing of the seven benzene rings which produces the π–π interaction between the aromatic rings of Tyloxapol while such effect is absent in TX-100. Moreover, the absolute photoluminescence quantum yield of Tyloxapol is 9% when the emission spectrum of Tyloxapol is at 360 nm. It also can be seen from Fig. 2 that the UV/vis absorption spectrum shows a broad absorption band between 300–400 nm which is consistent with the π–π* transition of C[double bond, length as m-dash]C.47 From a detailed photoluminescence study, it also can be found that as the excitation wavelength increases (Fig. 2 and S1), the emission peak shifts to longer wavelength (from about 375 nm to about 445 nm with a dependence on the excitation wavelengths) and the intensity continually decreases and a very bright blue luminescence under the illumination of UV (365 nm) light can be clearly seen in the inset of Fig. 2.
image file: c6ra25583c-f2.tif
Fig. 2 UV-vis absorption spectra (a) and the FL emission spectra (b) of 3 mmol L−1 Tyloxapol recorded for progressively longer excitation wavelengths in 10 nm increments from 310 nm to 400 nm. Inset: photographs taken under daylight (left) and 365 nm UV light (right) for 3 mmol L−1 Tyloxapol.

In our previous study, it has been also demonstrated that with the increase of the concentration of Tyloxapol, the fluorescence intensity of Tyloxapol increased continually and when its concentration reached 0.02 mmol L−1, the fluorescence intensity increased sharply (Fig. S2a) which is nearly consistent with the cmc of Tyloxapol (0.03 mmol L−1) because of the formation of micelles. Moreover, the variation of the light scattering intensities as a function of the concentration of Tyloxapol (Fig. S2b) also indicates that the light scattering intensity increased sharply (0.03 mmol L−1) which is also nearly consistent with the cmc of Tyloxapol. This is because that the formation of micelles made the Tyloxapol molecules accumulating more closely and induced a stronger π–π interaction and this phenomenon can be called aggregation-induced emission (AIE).48–50 Thus, in our next experiments, the concentration of Tyloxapol was still fixed at 3 mmol L−1 which is above the cmc of Tyloxapol and has strong fluorescence intensity which is benefit for further study.

MnO4 detection by Tyloxapol

In our previous study, it has been demonstrated that Tyloxapol was a sensitive and selective fluorescence sensor for the detection of Fe3+ directly in water over a wide range of metal cations including Na+, K+, Ag+, Hg2+, Cd2+, Co2+, Cu2+, Cr3+, Mn2+, Ba2+, Zn2+, Ni2+, Mg2+, Ca2+, and Pb2+.51 The possible mechanism of fluorescence quenching may be ascribed to the formation of complexes between Tyloxapol and Fe3+. Thus, in this paper, we want to test the sensitive and selective fluorescence behavior of Tyloxapol for a variety of different anions, including Cl, Br, I, NO3, H2PO4, HCO3, OH, ClO4, Ac, SO42−, HPO42−, CO32−, C2O42−, S2−, SO32−, Cr2O72− and MnO4. Firstly, the sensing behavior of Tyloxapol (3 mmol L−1) by testing the changes of the fluorescence intensity was investigated by mixing it with different anions (200 μmol L−1) mentioned above. From the FL experimental results, it can be seen that no apparent FL signal changes of the solutions are observed with the addition of most anions as shown in Fig. 3A. However, the addition of I, Cr2O72− and MnO4 affected the FL spectra and quenched the FL. Especially for Cr2O72− and MnO4, an obvious FL decrease was observed and the emission intensity was quenched nearly ∼78% and ∼99%, respectively.
image file: c6ra25583c-f3.tif
Fig. 3 (A) Change in fluorescence intensity of 3 mmol L−1 Tyloxapol upon addition of various anions including Cl, Br, I, NO3, H2PO4, HCO3, OH, ClO4, Ac, SO42−, HPO42−, CO32−, C2O42−, S2−, SO32−, Cr2O72− and MnO4. (B) Selectivity of Tyloxapol toward MnO4. Red bars represent the addition of various anions to the blank solution and black bars represent the subsequent addition of MnO4 (200 μmol L−1) to the above solutions (Tyloxapol + An + MnO4). Excitation wavelength = 360 nm. (C) Photographs of the aqueous Tyloxapol containing 200 μmol L−1 various anions under 365 nm UV light. From left to right: blank, Cl, Br, I, NO3, OH, Ac, SO42−, SO32−, S2−, Cr2O72− and MnO4.

The reason for Cr2O72− and MnO4 to quench the fluorescence of Tyloxapol may be because of inner filter effect (IFE). It is well-known that a high efficiency of the IFE needs a good spectral overlap between the absorption band of the absorber and the excitation band or emission band of the fluorophore.52,53 Therefore, it is important to choose a suitable absorber and fluorophore pair for the IFE-based fluorescent chemosensor.54 As shown in Fig. 4A, the excitation wavelength of Tyloxapol has range from 310 to 360 nm (Fig. 4A, a), and the emission wavelength of Tyloxapol has range from 380 to 450 nm (Fig. 4A, b); however, Mn(VII) exhibits broad UV-vis absorption from 270 to 380 nm (Fig. 4B, a), fully covered the excitation band of Tyloxapol. UV-vis absorption of Cr(VI) can also partly cover the excitation band of Tyloxapol (Fig. 4B, b), which can explain when added MnO4 and Cr2O72− to Tyloxapol solution, the FL can quenching obviously. Therefore, the absorbance enhancement of Mn(VII) could be successfully converted to fluorescence quenching of Tyloxapol, which ensures that the IFE occurs in a highly efficient way.


image file: c6ra25583c-f4.tif
Fig. 4 (A) FL excitation (a) and emission (b) spectra of Tyloxapol (3 mmol L−1) and (B) UV-vis absorption spectrum of Mn(VII) (a) and Cr(VI) (b).

Because MnO4 has the highest quenching efficiency of Tyloxapol, in our next study, we focus on MnO4 for further study. For an excellent chemosensor, high selectivity is a matter of necessity and an important evaluation index.55 The selectivity of Tyloxapol toward MnO4 was determined by contrast experiments of the MnO4 solutions mixed with other common anions Cl, Br, I, NO3, H2PO4, HCO3, OH, ClO4, Ac, SO42−, HPO42−, CO32−, C2O42−, S2−, SO32− and Cr2O72− (200 μmol L−1) (Fig. S3). In Fig. 3B, the black bars represent the fluorescence intensity of Tyloxapol in the presence of MnO4 in solution together with above individual anions. It can be seen that excepted S2−, MnO4 showed high impact on the fluorescence intensity when compared to the red bars which correspond to the fluorescence intensity of a solution with the same anion in the absence of MnO4. These results clearly demonstrate that the Tyloxapol-based MnO4 sensor is highly sensitive and selective toward MnO4 in the presence of other common anions excepted S2− in our study.

Then, the capability of Tyloxapol for quantitative detection of MnO4 was evaluated. As shown in Fig. 5A, the FL intensity of Tyloxapol decreases gradually with increasing concentration of MnO4, indicating that addition of MnO4 ions can effectively quench the fluorescence of Tyloxapol. Fig. 5B shows that the FL property change is the most sensitive as the MnO4 concentration increases from 10 to 100 μmol L−1 and then slows down with a further increase in MnO4 concentration. When the MnO4 concentration is above 200 μmol L−1, most of Tyloxapol molecules have been surrounded by MnO4, and thus there is no big change in the FL property. Moreover, a good linear correlation (R2 = 0.997) is observed over the concentration range of 0–120 μmol L−1 and the detection limit (DL)56,57 of 0.3924 μmol L−1 is obtained based on a 3d/slope (Fig. S5). Accord to Integrated Wastewater Discharge Standard Grade I (GB8978-2012), the total manganese content in sewage couldn't more than 2 mg L−1 (37 μM), that means our probe was sensitive enough to detect MnO4. Therefore, these sensors are responsible for micromolar determination of MnO4 in various samples.


image file: c6ra25583c-f5.tif
Fig. 5 (A) Fluorescence spectra of Tyloxapol (3 mmol L−1) recorded upon the addition of various amounts of MnO4 ions. Excitation wavelength = 360 nm. (B) The relationship between (I0I)/I0 and MnO4 from 0 to 200 μmol L−1. Inset is a linear region. I and I0 are the FL intensities of Tyloxapol at 360 nm in the presence and absence of MnO4, respectively.

Furthermore, it can be seen that the increase of MnO4 concentration can not only quench the FL intensity, but also cause a red-shift of the FL band due to the additions of MnO4 induce the conformation change of Tyloxapol. However, although the addition of MnO4 changed the conformation of Tyloxapol and induced a red shift behavior, it did not change the aggregation behavior of Tyloxapol which are always vesicles for Tyloxapol and Tyloxapol/MnO4 solutions as shown in Fig. 6A and B.


image file: c6ra25583c-f6.tif
Fig. 6 (A) TEM of 3 mmol L−1 Tyloxapol. (B) TEM of 3 mmol L−1 Tyloxapol/200 μmol L−1 MnO4.

S2− and aldehydes detection by Tyloxapol/MnO4 platform

Because on the above study, it has been observed that besides other anions, S2− can recover the FL intensity of Tyloxapol. Thus, another sensing application of the Tyloxapol/MnO4 platform to probe S2− was also investigated. We added all kinds of anions to the Tyloxapol/MnO4 system, it can be observed that upon the addition of S2−, the fluorescence of Tyloxapol/MnO4 could be turned on (Fig. 3B) and the reason of S2− which makes the fluorescence turned on obviously may be because of the oxidation–reduction reaction between S2− and MnO4 (2MnO4 + 5S2− + 16H+ = 5S↓ + 2Mn2+ + 8H2O). A good linear correlation (R2 = 0.9838) is observed over the concentration range of 0.13–0.2 mmol L−1 and the DL could low as 0.039 μmol L−1 based on a 3d/slope as shown in Fig. S4. Moreover, TEM result also indicated that the addition of S2− didn't destroy the aggregation behavior of Tyloxapol/MnO4 and still remained the vesicle structure as shown in Fig. 7C. We also did the UV/vis absorption spectrum of 3 mmol L−1 Tyloxapol/200 μmol L−1 MnO4/500 μmol L−1 S2−, as shown in Fig. S5a, there was no apparent UV/vis absorption for the sample and the FL became turn-on, which also proved that MnO4 could quench the fluorescence because of IFE.
image file: c6ra25583c-f7.tif
Fig. 7 (A) FL spectra of Tyloxapol (3 mmol L−1) + MnO4 (200 μmol L−1) recorded upon the addition of various amounts of S2− ions. Excitation wavelength = 360 nm. (B) Time-resolved fluorescence of Tyloxapol with an excitation at 360 nm in the absence (black) and in the presence of MnO4 (red), and MnO4/S2− (blue). (C) TEM of 3 mmol L−1 Tyloxapol/200 μmol L−1 MnO4/500 μmol L−1 S2−.

To get an insight into the quenching and recovery behavior in this system, time-resolved fluorescence by the fluorescence upconversion technique have been measured. The fluorescence decay behavior of Tyloxapol were shown in Fig. 7B, and the exponential fit results are summarized in Table 1. It can be seen that the lifetimes for pure Tyloxapol were analysed using the multi-exponential mode giving as a result two decay lifetimes of 1.7684 and 7.5899 ns (χ2 = 1.062). After the addition of MnO4, the lifetime of Tyloxapol did not change significantly, the values being 1.8729 and 8.8375 ns (χ2 = 1). The addition of S2− to Tyloxapol/MnO4 solution gave similar results of 1.8017 and 7.2363 ns (χ2 = 0.997). The changes in lifetimes after the addition of these molecules indicate that the changes in FL are due to the dynamic quenching.

Table 1 Fluorescence lifetimes obtained with two-exponential fit of the fluorescence decay curves of the Tyloxapol alone, Tyloxapol/MnO4, and Tyloxapol/MnO4/S2−, respectively
Sample τ1/ns (%) τ2/ns (%)
3 mmol L−1 Tyloxapol 1.7684(80.98) 7.5899(19.02)
3 mmol L−1 Tyloxapol + 200 μmol L−1 MnO4 1.8729(79.05) 8.8375(20.95)
3 mmol L−1 Tyloxapol + 200 μmol L−1 MnO4 + 500 μmol L−1 S2− 1.8017(85.21) 7.2363(14.79)


We also used the Tyloxapol/MnO4 fluorescent probe to detect the organic pollutant. As shown in Fig. 8A, we added four kinds of conventional organic pollutants (aniline, phenol, formaldehyde and glyoxal) to Tyloxapol/MnO4 system and it can be observed that only the addition of formaldehyde and glyoxal can make the quenched fluorescence turned on. This may due to the reaction between aldehyde and MnO4, so that Tyloxapol molecules which were surrounded by MnO4 were released and the luminescence properties were recovered. From our experiment, it can be concluded that the platform of Tyloxapol/MnO4 could be utilized to probe S2− and aldehydes through the oxidation–reduction reaction and some other anions and aldehydes can cause some small influences but it does not affect the detection of sulfur ions.


image file: c6ra25583c-f8.tif
Fig. 8 (A) Fluorescence intensity of Tyloxapol (3 mmol L−1) + MnO4 (200 μmol L−1) recorded upon the addition of different organics. Excitation wavelength = 360 nm. (B) Red bars represent the addition of various organic pollutant to the Tyloxapol + MnO4 solution and black bars represent the Tyloxapol + MnO4 solutions. Caniline = Cphenol = 10 mmol L−1, Cformaldehyde = 4.4 mol L−1, Cglyoxal = 1.7 mol L−1, excitation wavelength = 360 nm. (C) TEM of 3 mmol L−1 Tyloxapol/200 μmol L−1 MnO4/4.4 mol L−1 HCHO.

We also did the UV/vis absorption spectrum of 3 mmol L−1 Tyloxapol/200 μmol L−1 MnO4/4.4 mol L−1 HCHO, as shown in Fig. S5b, there was no apparent UV/vis absorption for the sample and the FL property of Tyloxapol turned on because of the reduction of MnO4 by HCHO (3HCHO + 4MnO4 = 3CO2 + 4MnO2 + 4OH + H2O), which also proved that MnO4 quench the FL because of IFE. TEM result also indicated that the addition of HCHO didn't destroy the aggregation behavior of Tyloxapol/MnO4 and still remained the vesicle structure as shown in Fig. 8C. We added different concentrations of HCHO to Tyloxapol/MnO4 system, it can be seen that as the HCHO concentration increased, the fluorescence intensity increased as shown in Fig. S6. A good linear correlation (R2 = 0.9855) is observed over the concentration range of 0.1–0.8 mol L−1 and the DL could low as 0.333 mmol L−1 based on a 3d/slope as shown in Fig. S7. Accord to Integrated Wastewater Discharge Standard Grade I (GB8978-2012), the total sulfur and HCHO content in sewage couldn't more than 1 mg L−1 (0.03 mM) which means that our probe was not sensitive enough to detect S2− and HCHO in real water. Therefore, we will improve the limit detection in our future work by changing the external conditions.

Mechanism explanation

Thus, the schematic representation of fluorescent Tyloxapol for detection of MnO4 and S2− is shown in Scheme 1. First, MnO4 can quench the FL of Tyloxapol due to IFE. Then, S2− can react with MnO4 which can induce MnO4 to remove from the surface of Tyloxapol. Thus, the FL of Tyloxapol could be turned on. Therefore, by taking advantage of the observed FL change, we can fabricate a facile FL sensor that allows detection of MnO4 and S2−.
image file: c6ra25583c-s1.tif
Scheme 1 Schematic illustration of FL assays for Mn(VII), S(II) and aldehydes based on the IFE of Tyloxapol.

Conclusions

A water soluble fluorescent oligomer (Tyloxapol) was developed as a turn-off fluorescence chemosensor for detecting Mn(VII) ions. The results of fluorescence assay strongly suggests that Tyloxapol is more sensitive to the presence of MnO4 when compared to the other anions, including Cl, Br, I, NO3, H2PO4, HCO3, OH, ClO4, Ac, SO42−, HPO42−, CO32−, C2O42−, S2−, SO32− and Cr2O72− under the same conditions, which demonstrated that Tyloxapol-based sensor can be used for label-free detection of MnO4 based on the IFE. Moreover, Tyloxapol/MnO4 platform can be further used as another turn-on sensing probe to detect S2− against various other anions and aldehydes against various other organic pollutants. These results can illustrate that Tyloxapol as a fluorescent probe should have a broad range of usage in the fields of analytic determination and polluted water detection.

Acknowledgements

We gratefully acknowledge the financial support from the National Natural Science Foundation of China (21203109) and Young Scholars Program of Shandong University (2016WLJH20).

References

  1. S. Kubik, Chem. Soc. Rev., 2010, 39, 3648–3663 RSC.
  2. Z. C. Xu, X. Q. Chen, H. N. Kim and J. Y. Yoon, Chem. Soc. Rev., 2010, 39, 127–137 RSC.
  3. N. Busschaert, C. Caltagirone, W. V. Rossom and P. A. Gale, Chem. Rev., 2015, 115, 8038–8155 CrossRef CAS PubMed.
  4. X. Lou, D. Ou, Q. Li and Z. Li, Chem. Commun., 2012, 48, 8462–8477 RSC.
  5. C. Kong, R. Jia, Y. Zhao, J. Wang, Z. Qua and H. Zhang, RSC Adv., 2016, 6, 63548 RSC.
  6. T. Gunnlaugsson, M. Glynn, G. M. Tocci, P. E. Kruger and F. M. Pfeffer, Chem. Rev., 2006, 250, 3094–3117 CAS.
  7. L. E. S. Figueroa, M. E. Moragues, E. Climent, A. Agostini and R. M. Manez, Chem. Soc. Rev., 2013, 42, 3489–3613 RSC.
  8. I. Ravikumar and P. Ghosh, Chem. Soc. Rev., 2012, 41, 3077–3098 RSC.
  9. S. R. J. Oliver, Chem. Soc. Rev., 2009, 38, 1868–1881 RSC.
  10. Y. Liu and X. X. Wang, Anal. Methods, 2013, 5, 1442–1448 RSC.
  11. L. E. Korshoj, A. J. Zaitouna and R. Y. Lai, Anal. Chem., 2015, 87, 2560–2564 CrossRef CAS PubMed.
  12. U.S. Department of Health and Human Services, Toxicological Profile for Chromium; Public Health Service Agency for Toxic Substances and Disease Registry, Washington, DC, 1991 Search PubMed.
  13. M. Wu and S. Janssen, Environ. Sci. Technol., 2011, 45, 366–367 CrossRef CAS PubMed.
  14. B. Qiu, L. L. Xue, Y. P. Wu, Z. Y. Lin, L. H. Guo and G. N. Chen, Talanta, 2011, 85, 339–344 CrossRef CAS PubMed.
  15. M. R. Ganjali, V. K. Gupta, M. Hosseini, Z. R. Sarmazdeh, F. Faridbod, H. Goldooz, A. R. Badiei and P. Norouzi, Talanta, 2012, 88, 684–688 CrossRef CAS PubMed.
  16. B. Ding, S. X. Liu, Y. Cheng, C. Guo, X. X. Wu, J. H. Guo, Y. Y. Liu and Y. Li, Inorg. Chem., 2016, 55, 4391–4402 CrossRef CAS PubMed.
  17. J. W. Goode, Adv. Chem., 1985, 14, 217–227 Search PubMed.
  18. S. E. Sayed, L. Pascual, M. Licchelli, R. M. Manez, S. Gil, A. M. Costero and F. Sancenon, ACS Appl. Mater. Interfaces, 2016, 8, 14318–14322 Search PubMed.
  19. A. N. Ramdzan, M. I. Almeida, M. J. McCullough and S. D. Kolev, Anal. Chim. Acta, 2016, 919, 47–54 CrossRef CAS PubMed.
  20. P. Yang, C. W. Lau, J. Y. Liang, J. Z. Lu and X. Liu, Luminescence, 2007, 22, 473–479 CrossRef CAS PubMed.
  21. Z. Li, L. K. Jacobus, W. P. Wuelfing, M. Golden, G. P. Martin and R. A. Reed, J. Chromatogr., A, 2006, 1104, 256–262 CrossRef PubMed.
  22. X. L. Gou, G. X. Wang, J. S. Yang, J. Park and D. Wexler, J. Mater. Chem., 2008, 18, 965–969 RSC.
  23. S. Pirsa and N. Alizadeh, Sens. Actuators, B, 2010, 147, 461–466 CrossRef CAS.
  24. T. Itoh, I. Matsubara, W. Shin, N. Izu and M. Nishibori, Sens. Actuators, B, 2008, 128, 512–520 CrossRef CAS.
  25. H. Tanaka and Y. Kanno, Jpn. J. Appl. Phys., Part 1, 2007, 46, 7509–7511 CrossRef CAS.
  26. K. Mitsubayashi, H. Matsunaga, G. Nishio, S. Toda, Y. Nakanishi, H. Saito, M. Ogawa and K. Otsuka, Sens. Actuators, B, 2005, 108, 660–664 CrossRef CAS.
  27. P. Jacquinot, A. W. E. Hodgson, B. Muller, B. Wehrli and P. C. Hauser, Analyst, 1999, 124, 871–876 RSC.
  28. S. Iwasawa, Y. Kikuchi, Y. Nishiwaki, M. Nakano, T. Michikawa, T. Tsuboi, S. Tanaka and T. Uemura, J. Occup. Health, 2009, 51, 38–47 CrossRef CAS PubMed.
  29. N. Sang, Y. Yun, H. Li, L. Hou, M. Han and G. K. Li, Toxicol. Sci., 2010, 114, 226 CrossRef CAS PubMed.
  30. J. Flavioda, S. Petruci and A. A. Cardoso, Anal. Methods, 2015, 7, 2687–2692 RSC.
  31. T. L. Guidotti, Int. J. Toxicol., 2010, 29, 569–581 CrossRef CAS PubMed.
  32. X. Lou, H. Mu, R. Gong, E. Fu, J. Qin and Z. Li, Analyst, 2011, 136, 684–687 RSC.
  33. S. Balasubramanian and V. Pugalenthi, Water Res., 2000, 34, 4201–4206 CrossRef CAS.
  34. M. S. P. Silva, C. X. Galhardo and J. C. Masini, Talanta, 2003, 60, 45–52 CrossRef CAS PubMed.
  35. M. Colon, J. L. Todoli, M. Hidalgo and M. Iglesias, Anal. Chim. Acta, 2008, 609, 160–180 CrossRef CAS PubMed.
  36. B. Spilker, J. Randhahn, H. Grabow, H. Beikirch and P. Jeroschewski, J. Electroanal. Chem., 2008, 612, 121–130 CrossRef CAS.
  37. M. G. Choi, S. Cha, H. Lee, H. L. Jeon and S. K. Chang, Chem. Commun., 2009, 7390–7392 RSC.
  38. R. F. Huang, X. W. Zheng and Y. J. Qu, Anal. Chim. Acta, 2007, 582, 267–274 CrossRef CAS PubMed.
  39. C. C. Wang, S. Feng, L. Y. Wu, S. Y. Yan, C. Zhong, P. Guo, R. Huang, X. C. Weng and X. Zhou, Sens. Actuators, B, 2014, 190, 792–799 CrossRef CAS.
  40. T. Suzuki, A. Hiolki and M. Kurahashi, Anal. Chim. Acta, 2003, 476, 159–165 CrossRef CAS.
  41. R. M. Manez and F. Sancenon, Chem. Rev., 2003, 103, 4419–4476 CrossRef PubMed.
  42. C. Y. Lai, B. G. Trewyn, D. M. Jeftinija, K. Jeftinija, S. Xu, S. Jeftinija, V. S. Y. Lin and J. Am, J. Am. Chem. Soc., 2003, 115, 4451–4459 CrossRef PubMed.
  43. M. Numata, C. Li, A. H. Bae, K. Kaneko, K. Sakurai and S. Shinkai, Chem. Commun., 2005, 37, 4655–4657 RSC.
  44. H. S. Jung, P. S. Kwon, J. W. Lee, J. I. Kim, C. S. Hong, J. W. Kim, S. Yan, J. Y. Lee, J. H. Lee, T. Joo and J. S. Kim, J. Am. Chem. Soc., 2009, 131, 2008–2012 CrossRef CAS PubMed.
  45. X. Xin, Y. Y. Zhu, X. R. Cao and G. Y. Xu, J. Surfactants Deterg., 2014, 17, 71–83 CrossRef CAS.
  46. J. L. Shen, J. Y. Pang, T. Kalwarczyk, R. Hołyst, X. Xin, G. Y. Xu, X. Y. Luan and Y. J. Yang, J. Mater. Chem. C, 2015, 3, 8104–8113 RSC.
  47. S. J. Zhu, Q. N. Meng, L. Wang, J. H. Zhang, Y. B. Song, H. Jin, K. Zhang, H. C. Sun, H. Y. Wang and B. Yang, Angew. Chem., Int. Ed., 2013, 52, 3953–3957 CrossRef CAS PubMed.
  48. Z. Zhao, J. W. Lam and B. Z. Tang, Soft Matter, 2013, 9, 4564–4579 RSC.
  49. Y. Hong, J. W. Lam and B. Z. Tang, Chem. Soc. Rev., 2011, 40, 5361–5388 RSC.
  50. Y. Yuan, C. Zhang, M. Gao, R. Zhang, B. Z. Tang and B. Liu, Angew. Chem., Int. Ed., 2015, 54, 1780–1786 CrossRef CAS PubMed.
  51. L. L. Zhao, X. Xin, P. Ding, A. X. Song, Z. C. Xie, J. L. Shen and G. Y. Xu, Anal. Chim. Acta, 2016, 926, 99–106 CrossRef CAS PubMed.
  52. D. W. Zhang, Z. Y. Dong, X. Z. Jiang, M. Y. Feng, W. Li and G. H. Gao, Anal. Methods, 2013, 5, 1669–1675 RSC.
  53. L. Xu, B. X. Li and Y. Jin, Talanta, 2011, 84, 558–564 CrossRef CAS PubMed.
  54. M. Zheng, Z. G. Xie, D. Qu, D. Li, P. Du, X. B. Jing and Z. C. Sun, ACS Appl. Mater. Interfaces, 2013, 5, 13242–13247 CAS.
  55. Y. Wang, M. Yu, Y. Yu, Z. Bai, Z. Shen, F. Li and X. You, Tetrahedron Lett., 2009, 50, 6169–6172 CrossRef CAS.
  56. F. Zhang, L. Wang, S. H. Chang, K. L. Huang, Y. Chi, W. Y. Hung, C. M. Chen, G. H. Lee and P. T. Chou, Dalton Trans., 2013, 42, 7111–7119 RSC.
  57. L. N. Neupane, J. M. Kim, C. R. Lohani and K. H. Lee, J. Mater. Chem., 2012, 22, 4003–4008 RSC.

Footnote

Electronic supplementary information (ESI) available. See DOI: 10.1039/c6ra25583c

This journal is © The Royal Society of Chemistry 2017