Mizuki
Tenjimbayashi
a,
Hirokazu
Komatsu
b,
Masaaki
Akamatsu
c,
Waka
Nakanishi
b,
Koji
Suzuki
a,
Jonathan P.
Hill
b,
Seimei
Shiratori
*a and
Katsuhiko
Ariga
b
aDepartment of Integrated Design Engineering, Faculty of Science and Technology, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, Yokohama, Kanagawa 223-8522, Japan. E-mail: shiratori@appi.keio.ac.jp
bWPI-MANA, National Institute for Materials Science (NIMS), 1-1 Namiki, Tsukuba, Ibaraki 305-0044, Japan
cThe Matile group, University of Geneva, 30 Quai Ernest Ansermet, 1211 Geneva 4, Switzerland
First published on 28th January 2016
Monitoring potassium levels in blood is a significant aspect of clinical analysis. For this reason, polymeric bulk optodes have received much attention for their use in portable and easy-to-use analysis systems in situ determination without additional calibration. However, blood contamination on the detection area of the sensor can hinder accurate sensing and also increases risk of infection from the wounds. In this paper, we report a system for determination of potassium in blood which has the additional advantage of being blood-fouling resistant. We have replaced the generally used poly(vinyl chloride) (PVC) with hydrophobic fluorinated poly(vinylidene fluoride–hexafluoropropylene) (PVDF–HFP) for preparation of a polymeric bulk optode. Sensing ability in the visual range of the polymeric bulk optode was retained despite the variation of the polymer matrix. These polymeric bulk optodes are suitable for potassium determination in blood with the PVDF–HFP-based optode possessing better blood antifouling properties than the PVC-based optode. The blood monitoring system described here represents the basis for functionalization of the optode toward safe and easily implementation in blood and in situ sensing applications.
Recent research has highlighted techniques operating based on an optical response, which may be adaptable for blood analysis.9 Alternatively, polymeric bulk optodes have been used for quantification of blood electrolytes. Introduction of an ionophore selective for a reference ion into the sensor membrane permits monitoring of the degree of protonation of a dyestuff which can in turn be used to quantify the activity of the primary ion in analyte samples because the response mechanism is based on a competitive ion–exchange equilibrium.10,11 Optical response of an optode device is usually observed in absorbance or fluorescence mode12,13 and, since the visual responsive of the optode can be used to quantify the activity of the primary ion in an analyte, it can be applied for blood analysis in the absence of an electrical supply (such as occurs at the time of a natural disaster or in remote locations).14 However, most approaches to blood analysis are based on fluorescence response optodes not visually responsive optode.12,13,15 This is largely due to components of blood contaminating the detection area of the sensor, which can hinder accurate sensing in the visual region16 and also increases risk of infection from the wounds.17,18
Here we present a visually responsive system for determination of potassium concentrations in blood.19,20 The system has the additional property that it resists fouling by blood analyte samples. While in most previous reports PVC was used to form polymer bulk optodes,21,22 we have attempted to use the fluorinated copolymer PVDF–HFP due to its greater hydrophobicity over PVC.23,24 We have also investigated the influence on optical response caused by changing to a lower surface tension polymer as well as evaluating the adherence qualities of blood on the optode by measuring the contact and sliding angles on the polymer.25 Sensing activity in the visual range of the polymeric bulk optodes was not affected by changing the polymer from PVC to PVDF–HFP with the PVDF–HFP-based optode exhibiting similar activity for potassium determination in blood as that of the PVC optode. The PVDF–HFP-based optode did however exhibit much better blood anti-fouling properties than those of the PVC-based optode. There have been only a few reports of the variation of the optode bulk polymer where PVC was not used. Alternative approaches have made use of a Si–O matrix or amphiphilic polymers for preparation of emulsion-based optodes.26–30 Additionally, there has been scant attention paid to the relationship between the interactions involved at the optode liquid interface and its sensing ability.31
MWz+ + zSO + zDOH+RO− ↔ SzOMOz+ROz− + zDO + zHW+ | (1) |
Here, KD-M13 was chosen as the responsive dye.33 As described in the preceding paragraph, the absorbance spectrum of this dye varies according to its degree of protonation (see Fig. S3 of the ESI†). Absorption spectra of the protonated state contain an absorption peak at 470 nm while increasing degrees of deprotonation result in the appearance and gradual increase in intensity of an absorption peak at 625 nm with a concurrent decrease in intensity of the absorption peak at 470 nm. These spectral changes are accompanied by a gradual colour variation from yellow to blue; a response that can be use in ratiometry.
Bis[(benzo-15-crown-5)-4-ylmethyl] pimelate was selected as the K+ ion selective ionophore and this combination of ionophore and dye showed a visual response in the pH26 range between 6 and 8, which includes the physiologically important pH value of 7.4 (ref. 35) (pH of human blood), and responses in this range were included in the linear region of the chemical equilibrium curve (see Fig. S4 of the ESI†).
It has been reported that the intensity of optical response varies according to the surface roughness of the polymeric bulk optode,36 or absorption peak shifts occur by adding nanorod structures into the polymeric bulk optode.7 Those changes were reported also to influence the binding constant of the ionophore or values of pKa.37,38 In this paper, we have investigated the effect of changing the surface tension of the polymer matrix. While surface roughness or morphology influences the interaction area between optode and fluid analytes, the surface tension (or surface energy) influences the osmotic action of the molecules between optode and the analyte.39Fig. 2 shows the sensing property of the K+ selective membrane where the base polymer was (a and b) PVDF–HFP or (c and d) PVC. The responses lie in the range from 10−4 M to 10−1 M, which includes the physiological level of K+ in blood.7 There was no apparent difference in the optical response or any shift of absorption peaks between the PVDF–HFP-based optode, with logKexch = −5.19, and PVC-based optode, with log
Kexch = −5.46. Thus, the surface tension does not influence optical response properties or cause shifts in absorption peaks (there was also no apparent change in response velocity).
The response curve of the PVDF–HFP-based optode for fluid analytes containing physiologically important cations as their chloride salts (K+, Na+, Mg2+, Ca2+) is shown in Fig. 3(a). The PVDF–HFP-based optode turned blue in 1 M KCl solution, but maintained its yellow colour in 1 M NaCl, MgCl2, or CaCl2 solution as shown in Fig. 3(b). From the response curve, we calculated the coupling constants Kexch as shown in Table 1 and ion selectivities Koptij as shown in Table 2. The results indicate that the sensor has sufficient selectivity for use in the analysis of blood samples (the ion selectivities required for blood are given in the literature7). As shown in Fig. 3(a), a linear response was obtained in the range from 10−4 M to 10−1 M indicating that these optodes are sufficiently selective to operate under a background of other blood electrolytes and so are suitable for physiological measurements.
![]() | ||
Fig. 3 (a) Response to KCl, NaCl, CaCl2, and MgCl2 (b) photograph of PVDF–HFP based optodes after immersion in 1 M KCl, NaCl, CaCl2, or MgCl2 contained in Tris-buffer. |
Ion | K exch |
---|---|
a These coupling constants were calculated from the equation listed in ESI. | |
K | 6.47 × 10−6 |
Na | 1.68 × 10−9 |
Mg | Unmeasurable |
Ca | Unmeasurable |
Ion | log![]() |
log![]() |
log![]() |
---|---|---|---|
a Selectivities were calculated from the equations listed in ESI. Selectivities required for blood analysis were obtained from ref. 7. | |||
Na | −3.59 | −3.14 | −3.09 |
Mg | At least less than −3 | −0.92 | −0.88 |
Ca | At least less than −3 | −1.39 | −1.31 |
Fig. 4 shows the response curve obtained by the standard addition method. A linear response was obtained in the range from 10−4 M to 10−1 M. Hence, the potassium level in human blood measured by using the standard addition method based on response curve was 5.57 ± 0.09 mM in Fig. 4(b), which is a valid level for human blood. For determination of blood potassium levels under emergency conditions or in remote areas, UV-vis absorption measurements are not convenient for quantification of colour variation of the sensor. Thus, we performed the quantification of colour variation using a colour difference meter, which is a highly portable device useful for instant measurements (see Fig. S5 of the ESI†). Colour difference meter measurement enabled the quantification of colour changes of the human blood by adding 3 mM potassium or 5 mM potassium. In addition, the response curve obtained by using the color difference meter was linear within the range from 10−4 M to 10−1 M similarly to that obtained using UV-vis spectrophotometry. In short, by using the optode in conjunction with a color difference meter allows measurement of millimolar potassium levels in blood by a simple protocol.
Although there was no apparent difference in optical response or absorption peak shift between the PVDF–HFP-based optode and PVC-based optode, we found that an antifouling property of the optode was introduced by changing the base polymer. Fig. 5 shows the blood contact angle and sliding angle of each polymer optode, and indicates that the PVDF–HFP-based optode ought to exhibit superior resistance to fouling by blood than the PVC-based optode due to the formers larger contact angle and smaller sliding angle. The surface tension of PVC is 39 mN m−1 while that of PVDF–HFP is 25 mN m−1.23 Young's equation indicates that lower surface tensions of solids lead to higher contact angles and weaker adhesion of the blood.40 Therefore, blood sliding angle is also reduced with increasing contact angle. When a blood droplet slides on the PVC based optode, the pinning of blood on the responding surface is observed (and some small contaminating material remains on deprotonated films based on PVC).41 For this reason, we constructed a colour histogram for each polymer optode (deprotonated by blood) just following sliding of a blood sample, as shown in Fig. 6. The red area indicates remaining contaminating blood. The blue coloured area indicates where the optode has reacted with blood. Blood contamination on the PVC-based optode was greater than that on the PVDF–HFP-based optode as can be seen from the histogram of red coloured area. These results indicate that the PVDF–HFP-based optode has improved properties of blood fouling resistance over the PVC based optode. Hence, this system can be used to realize accurate sensing of potassium concentrations in blood. In addition, we believe that this system can be adapted for use in other similar applications such as for determination of ions in other contaminated fluids by varying the combination of host molecule and dyestuff. Thus, it might be developed for environmental monitoring purposes.
![]() | ||
Fig. 5 Contact angle (θc, blue bar) and sliding angle (θs, green bar) of 20 μL pig blood on PVDF–HFP or PVC-based optode. Scheme at right illustrates the meaning of contact angle and sliding angle. |
Footnote |
† Electronic supplementary information (ESI) available: Equations for calculating coupling constants Kexch and ion selectivities Koptij; response curve for determination of potassium level in human blood by a standard addition method; SEM images before and after color change of the sensor; absorption spectra of KD-M13; optical response in the pH range 6 to 8; color value changes with the potassium addition in human blood obtained by color difference meter. See DOI: 10.1039/c5ra26514b |
This journal is © The Royal Society of Chemistry 2016 |