Huijuan Zhang*a,
Xianjuan Pangb and
Yuan Qia
aSchool of Material and Mechanical Engineering, Beijing Technology Business University, Beijing 100048, China. E-mail: zhanghuijuan@btbu.edu.cn; Tel: +86 10 68985337
bSchool of Chemical Engineering and Pharmaceutics, Henan University of Science and Technology, No. 263 Kaiyuan Road, Luoyang 471023, China
First published on 14th October 2015
It is important and challenging to design a hydrogel that combines mechanical strength and stimuli responsiveness. In this study, graphene oxide (GO) was incorporated into the sodium alginate/polyacrylamide (SA/PAM) hydrogel as the reinforcement to promote the mechanical strength of the hydrogel. The hydrogel was prepared via in situ free-radical polymerization in the presence of SA with AM as the monomer and GO as the reinforcement, resulting in a GO/SA/PAM semi-interpenetrating polymer network (IPN). SA, cross-linking agent (N,N′-methylenebisacrylamide, BIS) and GO proportions were optimized to obtain a hydrogel with superior compressive strength. The GO18/SA0.1/PAM/BIS0.01 nanocomposite hydrogel (GO 18 mg, SA 0.1 g, BIS 0.01 g) displayed a compressive strength as high as 65.6 MPa at the compressive deformation of 80%. The hydrogel exhibited pH dependent swelling behavior and a maximum swelling ratio could be observed at pH 4 for the hydrogels with varied GO content. Moreover, the swelling behaviors of the semi-IPN hydrogels are dependent on the GO amounts, and the GO18/SA0.1/PAM/BIS0.01 hydrogel sample shows a lower swelling ratio due to its robust inner structures.
Graphene oxide (GO), a precursor of graphene-based composites with many oxygenated defects, is a favorable candidate as polymer reinforcement to gain composite materials with improved mechanical performance.26–29 For example, Yu et al. prepared a tough and highly stretchable GO/polyacrylamide (PAM) nanocomposite hydrogel via in situ polymerization of AM in an aqueous suspension of GO.30 As prepared hydrogel exhibited high tensile strength, high toughness and a large elongation at break than that of the chemically cross-linked hydrogels. Nevertheless, the hydrogel cannot respond to the external stimulus, which restricted its application in many potential fields.
Another possible way to obtain high-strength hydrogel is the construction of an interpenetrating polymer network (IPN).31–33 IPN is conventionally defined as intimate combination of two polymers, which are partially interlaced at the polymer scale but are not covalently bonded to each other. Specifically, a semi-interpenetrating polymer network (semi-IPN or SIPN) is formed if only one of the components is crosslinked. Semi-IPN materials are unique alloys of crosslinked polymers, and the resulting “double network” or semi-IPN systems invariably display excellent mechanical performance that are superior to those of either of the two individual component polymers.34 Thus, this approach is considered to be a preferable way for designing multi-component hydrogels, which offer the possibility of combining multi-functions of the components and even exhibiting unexpected outstanding properties.35,36 During the last decade, particular interest has been focused to the semi-IPN containing natural linear macromolecules, i.e., sodium alginate, sodium carboxymethyl cellulose and carboxymethyl chitosan.37–47 These natural polysaccharides polyelectrolyte endow the hydrogel with advantageous biocompatibility, biodegradability and nontoxicity.48,49 Sodium alginate (SA) is an anionic and water soluble natural polymer which is widely used in food, pharmaceuticals and textile printing.50 SA can also be used as a hydrophilic polymer and a pH-responsive component for obtaining pH-sensitive hydrogels.51
Therefore, it is important to design and construct a biocompatible, pH-sensitive semi-IPN composite hydrogel with superior mechanical performance. To this end, a pH-responsive GO/PAM/SA composite hydrogel with interpenetrating polymer network was designed and synthesized. For the fabrication of the hydrogel, AM was polymerized in the presence of GO and SA, which formed a hydrogel by a chemical cross-linker (BIS). In the network, SA acted as one of the constituent and pH-sensitive moiety simultaneously. GO was included as the reinforcement, aiming to achieve desirable mechanical strength. The compressive tests of the composite hydrogel were investigated in terms of the contents of SA, BIS and GO. The pH-sensitive swelling behaviors of the hydrogels were studied. The rheology, morphologies, and the possible interactions between the components were also investigated. On the basis of the characterizations, a possible mechanism for the formation and pH responsiveness was proposed.
| Sample | AM (g) | SA (g) | APS (g) | BIS (g) | GO (g) | H2O (mL) |
|---|---|---|---|---|---|---|
| SA0.1/PAM/BIS0.01 | 3.6 | 0.10 | 0.010 | 0.010 | — | 15 |
| SA0.1/PAM/BIS0.02 | 3.6 | 0.10 | 0.010 | 0.020 | — | 15 |
| SA0.1/PAM/BIS0.03 | 3.6 | 0.10 | 0.010 | 0.030 | — | 15 |
| SA0.2/PAM/BIS0.01 | 3.6 | 0.20 | 0.010 | 0.010 | — | 15 |
| SA0.3/PAM/BIS0.01 | 3.6 | 0.30 | 0.010 | 0.010 | — | 15 |
| GO12/SA0.1/PAM/BIS0.01 | 3.6 | 0.10 | 0.010 | 0.010 | 0.012 | 15 |
| GO18/SA0.1/PAM/BIS0.01 | 3.6 | 0.10 | 0.010 | 0.010 | 0.018 | 15 |
| GO24/SA0.1/PAM/BIS0.01 | 3.6 | 0.10 | 0.010 | 0.010 | 0.024 | 15 |
![]() | (1) |
Typical procedure for deswelling experiment was conducted as follows: 100 mg hydrogel sample was immersed in an aqueous solution at room temperature for 24 hours to reach swelling equilibrium. The swollen gels were blotted with filter paper for further deswelling experiment. The deswelling behavior of the hydrogel was studied by recording the weight of water in the hydrogels at determined time. Water retention was calculated as:
![]() | (2) |
The semi-IPN SA/PAM hydrogels in the absence of GO, with varied proportions of SA and cross-linking agent (BIS), were firstly prepared to optimize the preparation conditions. The compressive strength of as-prepared hydrogels was measured to describe the differences between the samples. The obtained hydrogels for compressive tests were tested in equilibrium swelling state. The analysis of variance (ANOVA) was used to evaluate the contributions of SA and BIS concentrations to the compressive strength. The ANOVA statistic results showed the effects of SA and BIS concentrations were significant, since these effects presented p-values smaller than 0.01. This means that the probability of the null hypothesis to be true is less than 1%. As shown in Fig. 1(a), the compressive strength of the hydrogels goes down with the increasing SA amounts. The similar result was also reported by Gong et al.,35 who found that the molar ratio of the first to the second network is crucial for obtaining the DN mechanically strong gels. However, they did not provide possible explanations. It is known that the effective stress dissipation is the key to the toughness of a material.35 The above results showed that the mechanical stress was effectively dissipated in the hydrogel with the lower SA content. It could also be observed that the hydrogels with lower BIS concentration exhibited higher compressive strength (Fig. 1(b)). Generally speaking, the higher BIS content would result in an increase of crosslinking density, which would restrict the motion of macromolecular chains. Unsurprisingly, the hydrogel with higher content of crosslinking agent, i.e., SA0.1/PAM/BIS0.03, failed to undergo a large deformation due to the low mobility of its cross-linking polymer chains in the network.
As shown in the previous section, the semi-IPN SA0.1/PAM/BIS0.01 hydrogel sample (SA 0.1 g and BIS 0.01 g) showed advantageous mechanical properties. Therefore, the recipe was selected to investigate the effects of GO contents on the compressive strength, as shown in Fig. 2. The effect of GO proportions on the compressive strength is also analyzed by ANOVA. The results confirmed that the observed changes on the compressive strength could be ascribed to changes in the level of GO concentrations. As indicated in Fig. 2, the compressive strength firstly increased and then declined to a certain extent. The dependence of GO content on the compressive properties of GO/SA0.1/PAM/BIS0.01 was probably related to the dispersion of GO and its interfacial interaction with polymer chains, which will be discussed below.
To visualize the differences between the compressive strength of SA0.1/PAM/BIS0.01 and GO18/SA0.1/PAM/BIS0.01 hydrogels, the photographs of both samples under pressure were taken and shown in Fig. 3. GO18/SA0.1/PAM/BIS0.01 hydrogel displays excellent performance in ductility, which is tough enough to withstand high deformations in compression without obvious damage. As shown in Fig. 3(a)–(c), GO18/SA0.1/PAM/BIS0.01 hydrogel was not destroyed by compressing, even with an extremely high strain. Upon removing pressure, GO18/SA0.1/PAM/BIS0.01 hydrogel quickly recovered its original shape. In contrast, SA0.1/PAM/BIS0.01 hydrogel, prepared in the absence of GO, was crushed by compressing because of its brittleness (Fig. 3(d)–(f)).
![]() | ||
| Fig. 3 Photographs of GO18/SA0.1/PAM/BIS0.01 (a–c) and SA0.1/PAM/BIS0.01 hydrogels (d–f) under pressure. | ||
TG analysis is performed to indicate the changes of thermal stability of SA, GO sheets, SA0.1/PAM/BIS0.01 and GO/SA0.1/PAM/BIS0.01 hydrogels (Fig. 4). The mass loss peak for GO at about 200 °C can be ascribed to the pyrolysis of the labile oxygen containing functional group.52,53 Additionally, GO content in GO/SA0.1/PAM/BIS0.01 IPN gel can also be estimated to be 1.8 wt% according to TGA measurements. This value is a little higher than the original feed ratio (0.48 wt% GO). It reveals that GO sheets all participated in the cross-linking reaction indicating rather high reaction efficiency in water.28 It is observable that the thermal stability was raised for the composite hydrogel with GO as enhancement, suggesting strong interactions between GO sheets and polymer chains.
FT-IR could provide important information about the successful cross-linking reaction and the possible interactions between GO and polymer chains. For comparison, the FT-IR spectra of GO, SA0.1/PAM/BIS0.01 and GO/SA0.1/PAM/BIS0.01 hydrogel samples with the gradient GO concentrations were shown in Fig. 5. The obvious peaks at 1732, 1401, 1226 and 1046 cm−1 in the FT-IR spectrum of GO powder were attributed to C
O carbonyl stretching, aromatic C
C stretching, O–H deformation vibration, and asymmetric and symmetric C–O stretching in C–O–C group, respectively. In the FT-IR spectrum of SA0.1/PAM/BIS0.01, the bands at 3390, 2923, 2855 cm−1 in the high-frequency region were characteristic of N–H stretching and asymmetric and symmetric vibration of C–H stretching, respectively. The strong peak at 890 cm−1, which appears only in the spectrum of AM monomer due to the existence of
CH2,54 does not appear in the spectrum of all the tested hydrogels, confirming that AM monomer has been polymerized. Moreover, the characteristic absorption bands at 1059 and 1095 cm−1 could be ascribed to the stretching vibration C–O–C ether groups in SA, respectively. These data were in good accordance with the literature55 and indicated the successful incorporation of SA into the hydrogel network. The peak at 1612 cm−1 can be ascribed to NH2 bending vibration in PAM.30 It is worth noting that the peaks at 1612 cm−1 shifted and broadened with the increasing content of GO sheets. The shift could be ascribed to the presence of the hydrogen bonding interactions between the N–H bond of SA0.1/PAM/BIS0.01 and O–H bond of GO nanosheets.56,57
SEM is very helpful in characterizing the inner morphologies of the hydrogels. To prepare samples for SEM observation, it is necessary to treat the hydrogels by freeze-drying to make sure the porous structure is well preserved. Moreover, the freeze-dried samples are sliced by a microtome, which guarantee the bulk, instead of the surface of the hydrogel was observed. The hydrogel samples with varied crosslinking agent contents displayed distinct morphologies as shown in Fig. 6(a)–(c). After removing water, SEM images of SA0.1/PAM/BIS0.01 hydrogel show characteristic porous structure with the diameter ranging from 100 to 150 μm (Fig. 6(a)). The inner structure exhibits a thick block with sparse pores dispersed. Interestingly, the pore size of the SA0.1/PAM/BIS0.02 hydrogel becomes smaller, implying a tighter structure of the hydrogel (Fig. 6(b)). As the crosslinking agent concentration was further increased, the inner structure of the hydrogel transformed into a net-like morphology, implying a denser structure (Fig. 6(c)). The morphology evolution of the hydrogels suggested that the inner structure was closely dependent on the BIS proportion. It seemed that the inner structure of the SA0.1/PAM/BIS0.03 was finer and interconnected to each other to a greater extent, which implied that the polymer chains were greatly restricted. This trend was in good agreement with the compressive strength dependence on the BIS content. Comparing Fig. 6(a) and (d), it could be found that GO18/SA0.1/PAM/BIS0.01 presented a robust three dimensional structure. The pore diameter was evenly distributed, which ensured the stress transfer and was favorable for enhancing the mechanical properties. It should be noted that no obvious aggregation of GO nanosheets is observed, indicating a uniform distribution of GO sheets in the hydrogel.
Fig. 6(e) shows the possible concise mechanism for the formation of GO/SA0.1/PAM/BIS0.01 nanocomposite semi-IPN hydrogel. For the SA0.1/PAM/BIS0.01 hydrogel, covalently crosslinked PAM was formed in the presence of SA. Two types of polymer are partially intertwined at the polymer scale. As confirmed previously by FT-IR results, hydrogen bonding interaction existed in the GO/SA/PAM hydrogels. Upon the involvement of GO sheets, the emerging crosslinking points were formed due to the GO participating in the polymerization.30,58 Additionally, the functional groups on the surface the GO nanosheets offer hydrogen bonding interactions with the side chains of the polymer chains. These two factors contributed collaboratively to the enhanced mechanical properties of the nanocomposite hydrogel.
Rheology was utilized to characterize the viscoelastic behaviors of the hydrogels with the varied GO contents. To this end, the dependence of storage moduli (G′) on time, strain and angular frequency was measured, where G′ could reflect the elastic properties of the sample. It was confirmed that the shear modulus of the SA0.1/PAM/BIS0.01 initially increased after the introduction of GO sheets, and then experienced a decline when the content was further growing (Fig. 7(a)). This is consistent with the previous compressive tests of the hydrogels. Moreover, towards 1% of strain, obvious changes of the storage moduli were not witnessed with the prolonging time, indicating a minimal stress relaxation of the hydrogels (Fig. 7(b)). The frequency sweeping results also demonstrated the reinforcing effect of GO nanosheets (Fig. 7(c)). Moreover, the characteristic viscoelastic behaviors of the gels was confirmed, i.e. the values of G′ varied little with angular frequency, and G′ was significantly larger than G′′ over all measured frequencies.
![]() | ||
| Fig. 7 Dependence of storage modulus (G′) on (a) time, (b) strain and (c) angular frequency for SA0.1/PAM/BIS0.01 hydrogel and GO/SA0.1/PAM/BIS0.01 hydrogels. | ||
SA is a natural polyelectrolyte with many carboxylic groups in its molecular chain, which exhibit reversible hydration/dehydration in basic/acidic medium. Therefore, we investigated the influence of the pH values of the medium on the swelling ratios for the GO/SA/PAM hydrogels in the pH range of 2.2–8. It could be observed from Fig. 8 that the swelling ratio of the semi-IPN SA0.1/PAM/BIS0.01 hydrogel samples increased in the lower pH values, i.e., from 2 to 4. This raise in the swelling ratio may be ascribed to the change in the dissociation degree of carboxylic groups and the formation of the hydrogen bonds between –COOH and –CONH– groups: at lower pH values (below the pKa of carboxylic groups, ∼4.6), the –COO− groups in SA are protonated to –COOH groups. Meanwhile, the hydrogen bonds between –COOH and –CONH– groups are formed. Remarkably, these factors played crucial roles in the diminishing polymer/water interactions as well as the swelling ratio. The lower pH values of the medium, the stronger the hydrogen bonds and thus the smaller the swelling ratio of the hydrogels. When pH value is increased to ∼4, the carboxylic acid groups become ionized and the electrostatic repulsion between the molecular chains is predominate, which leads to the network expanding more, where a maximum swelling ratio is observed for the SA/PAM hydrogels. Beyond this value, a screening effect of the counter ions, i.e., GO12/SA0.1/PAM/BIS0.01 at pH 5–6, Na+, shields the charge of the carboxylate anions, which may prevent an efficient repulsion.37 As a result, a remarkable decrease in equilibrium swelling is observed. The similar phenomenon was also reported by Ma et al.37
The similar tendency is also observed for the GO incorporated nanocomposite hydrogels. However, the GO/SA/PAM hydrogel showed less sensitive response toward pH variations. This may be associated with the complex interactions of the network due to the inclusion of GO sheets. It was reported that the oxygen-containing groups on GO surface would participated in the radical chain transfer reactions during the free-radical polymerization, which resulted in the grafting of PAM macromolecules onto the layered GO sheets.37,58 In other words, these GO sheets acted as fresh chemical crosslinking points in the hydrogel formation and intercalated into the polymer networks of the hydrogel. Additionally, SA chains were entrapped and entangled to a great extent, which promoted the polymer–polymer interactions and hindered the SA interaction with water.
To evaluate the swelling behaviors of the hydrogels, the hydrogels were swelled in water and the weight was measured at determined time to trace the swelling ratio with the prolonging time (Fig. 9). As expected, the swelling process of all the tested hydrogel samples consists of two regimes: the first one is a relatively quickly increasing process and the subsequent one is a slow-increasing process. The swelling equilibrium of the hydrogel samples could be achieved within about 1000 min. Moreover, it could be observed from Fig. 9 that the swelling ratio of the composite hydrogels presented a nonmonotonic variation with the increasing GO proportion, that is, the swelling ratio firstly declined with the increasing GO loadings, and then increased with the GO content of 24 mg. It is accepted that the swelling behavior of the hydrogel depended significantly on the crosslinked density of the gel network.59,60 Generally, the hydrogel with higher cross-linking density, where the free motion of the polymer chains is restricted to a great extent, shows a lower swelling capacity due to the weakened polymer/water affinity. In GO/SA0.1/PAM/BIS0.01 hydrogel, GO nanosheets could act as a kind of cross-linker and formed plenty of cross-link points, which gave rise to a reduction of the swelling ratio. The differences in swelling behaviors confirmed the more robust network of the GO/SA0.1/PAM/BIS0.01 hydrogel.
![]() | ||
| Fig. 9 Swelling behaviors of SA0.1/PAM/BIS0.01 and GO/SA0.1/PAM/BIS0.01 hydrogels in distilled water. | ||
The reasons of the nonmonotonic variation of the swelling ratio with the GO loadings might be ascribed to the following factors. There are two competing effects in the GO/SA/PAM nanocomposite hydrogels in terms of swelling capacity. On the one hand, the incorporation of the GO sheets tends to interact with PAM chains and increases the cross-linked density, which would result in the decreased swelling ratio.61 On the other hand, the GO sheets containing plenty of functional groups, i.e. carboxylic, carboxyl, hydroxyl and ether groups on the surface, which could dramatically increase the density of the hydrophilic groups of the polymer networks.62 When the GO loadings were low, the cross-linked density increased significantly with the increase of the GO loadings, which resulted in the denser inner structures of the GO/SA/PAM network and thus the decreased swelling ratio. As the GO loadings were further increased, i.e. 24 mg, the positive effect of the GO nanosheets on the swelling capacity became apparent. The swelling ratio of the GO24/SA0.1/PAM/BIS0.01 hydrogel increased and was even higher than that of the conventional SA/PAM hydrogel.
The swelling capacities of SA0.1/PAM/BIS0.01 and GO/SA0.1/PAM/BIS0.01 hydrogels with various GO loadings in deionized water and in 0.9 wt% NaCl solution are shown in Fig. 10. ANOVA statistic results revealed a significant effect of gel type and medium with p < 0.01, respectively. The hydrogel samples showed satisfactory salt tolerance, that is, all the samples exhibited higher swelling ratio in 0.9 wt% NaCl solution than that in deionized water. It was reported by Huang et al.26 that the swelling ratio of the graphene oxide/poly(acrylic acid-co-acrylamide) hydrogels in 0.9 wt% NaCl solution declined sharply compared to that in deionized water. In this hydrogel system, SA was incorporated as a polyelectrolyte in small amount, i.e., 2.7 wt% of SA to the total amount of SA and AM in SA0.1/PAM/BIS0.01 sample. The majority constituent of the hydrogel was PAM, which is neutral and showed little sensitiveness towards ionic strength. The dried gel absorbs large amount of water due to its affinity with water molecules. The gel deswells with the prolonging time if exposed to the air, which is caused by the evaporation of the water molecules. The deswelling rate is an important factor and, in particular, high rates are needed in many applications. The deswelling behavior of the hydrogels was evaluated by measuring the swelling ratios of the hydrogels at determined time. The deswelling curves of the hydrogels are shown in Fig. 11. It could be observed that the investigated hydrogel samples, unfilled and GO filled, displayed a fast deswelling rate and all the samples kept stable within 8 hours. Considering the favorable salt resistance and fast deswelling rate, the semi-IPN nanocomposite hydrogels may be potentially applied in hygienics and agricultural areas.
| This journal is © The Royal Society of Chemistry 2015 |