Cyclic tetra[(indolyl)-tetra methyl]-diethane-1,2-diamine (CTet) impregnated hydrous zirconium oxide as a novel hybrid material for enhanced removal of fluoride from water samples

Nafisur Rahman*, Uzma Haseen and Mohammad Fazeel Khan
Department of Chemistry, Aligarh Muslim University, Aligarh-202002, U.P., India. E-mail: nafisurrahman05@gmail.com; Tel: +91-9412501208

Received 30th January 2015 , Accepted 22nd April 2015

First published on 22nd April 2015


Abstract

A hybrid material was prepared by incorporating cyclic tetra[(indolyl)-tetra methyl]-diethane-1,2-diamine (CTet) into hydrous zirconium oxide (HZO) via thorough mixing of previously prepared CTet in methanol and stirred for 7 h at 27 °C. CTet–HZO was characterized by FT-IR, 13C NMR, XRD, TGA-DTA, SEM coupled with EDX and TEM. The adsorption capacity of fluoride as a function of pH, sorbent dose, contact time, initial concentration of fluoride ions and temperature was examined in batch mode. Maximum fluoride adsorption (188.68 mg g−1) occurred in the pH range 3.5–4.5. The outstanding fluoride sorption property might be ascribed due to the presence of indole-NH groups. The Langmuir, Freundlich and Temkin isotherms were applied to fit the sorption equilibrium data. Based on R2 and average percentage error (APE), the best isotherm model fits follow the order: Freundlich > Temkin > Langmuir. The pseudo-second order kinetic model well fitted the sorption kinetic data which supported the chemisorption as the mechanism of interaction between sorbent and F. The hybrid material could be reused upto four sorption–desorption cycles with no significant decrease in F sorption capacity. The material has been applied successfully for the defluoridation of groundwater and river water.


1. Introduction

Elemental fluorine is the most electronegative1 and is widely dispersed as fluoride in the environment which is about 0.06–0.09% of the earth's crust.2 The release of fluoride to groundwater is dependent on the chemical and physical processes occurring between the groundwater and its geological environment.3,4 Fluoride enters the human body mainly through drinking water and food. The dental health benefits are obtained when the concentration of fluoride in drinking water is 0.8–1.0 mg L−1.5,6 U.S. Environmental protection agency has recommended 4.0 mg L−1 as maximum contaminant level for fluoride in drinking water,7 while WHO has set 1.5 mg L−1 as a permissible limit.8 However, if the fluoride concentration in drinking water exceeds the permissible limit, it can pose a health threat to millions of people around the world. The excessive intake of fluoride may cause dental9 and skeleton disorder.10 The risk of fluorosis associated with such water for human consumption is a problem faced by many countries of Asia, Africa, America and Europe where the fluoride concentration ranged from 0.01 to 3 mg L−1 in fresh water and 1–3.5 mg L−1 in groundwater.11,12

In recent years, several defluoridation processes such as precipitation,13 reverse osmosis,14 nanofiltration,15 electrocoagulation,16 electrodialysis,17 adsorption and other methods have been studied for the removal of fluoride from aqueous systems. Among various methods, the adsorption process is widely used and offers satisfactory results. The adsorption process seems to be more attractive for removal of fluoride in terms of cost, easy availability of adsorbent, simplicity of design and operation.18 Many inorganic adsorbents such as Al–Fe (hydr) oxide,19 Mg-doped nanoferrihydrite,20 titanium hydroxide derived adsorbent,21 alginate entrapped nanostructure Al(III)–Ce(IV) mixed oxide22 and bismuth oxide23 have been tested for removal of fluoride from water. Hydrous zirconium oxide exhibited high affinity towards fluoride through Lewis acid–base interaction and used as an effective sorbent for defluoridation. In addition, inorganic–organic hybrid materials have also the ability to remove fluoride from aqueous solution at solid–liquid interface. Adsorption potential of a combination of polymeric anion exchange resin and iron oxide with a goethite (α-FeOOH) structure has been assessed for fluoride removal from water.24 Swain et al.25 have synthesised zirconium(IV) ethylenediamine hybrid sorbent which showed maximum fluoride removal efficiency at pH 7. Recently, a porous polystyrene encapsulated zirconium phosphate nanocomposite was reported for fluoride ion retention and its adsorption capacity was found to be 6.65 mg g−1 at pH 3.26

The main objective of present study is to develop a hybrid material by impregnating cyclic tetra[(indolyl)-tetra methyl]-diethane-1,2-diamine (CTet), an indole derivative, into hydrous zirconium oxide (HZO) and to evaluate its properties for efficient fluoride removal from water samples. Previously, indole-3-carbinol cyclic tetramer derivative was used as a promising anticancer agent with antiproliferative activity in breast cancer cells.27 Single-walled carbon nanotubes have been functionalized for delivery of indole-3-carbinol cyclic tetrameric derivative to breast cancer cell lines in an efficient way.28 Moreover, polypyrrole and indole derivatives have been identified as potential ligand and ion sensing scaffold.29 Recent studies have suggested that these materials have high potential for binding with fluoride through indole NH⋯F interaction.30 Functionalization of hydrous zirconium oxide with CTet would exhibit enhanced fluoride retention owing to the increased number of indole-NH groups in the hybrid material. To the best of our knowledge, no literature is available concerning the immobilization of CTet on any hydrous metal oxide for defluoridation.

2. Experimental methods

2.1. Reagents

Sodium fluoride (Merck, India) was used for the preparation of stock solution of fluoride (1000 mg L−1) by dissolving an appropriate amount in distilled water and stored in polyethylene bottle. 2,3-Benzopyrrole (indole) was purchased from Himedia, (Mumbai, India). Formaldehyde, ethylenediamine, ammonia, acetic acid, and zirconium oxychloride were obtained from Merck (Mumbai, India). Water used in all experiments was doubly distilled.

2.2. Preparation of cyclic tetra[(indolyl)-tetra methyl]-diethane-1,2-diamine (CTet)

The synthesis of 2,3-dimer of Mannich base, (N1-[(1H-indol-2-yl)-(1H-indol-3-yl)-methyl]-ethane-1,2-diamine), was carried out according to the procedure reported in literature.31 To a solution containing 2,3-dimer of Mannich base (10.0 mmol) and formaldehyde (37%, 14.6 mmol) in methanol, 4.0 mL of acetic acid (99.8%) was added and the mixture was refluxed in dark for 2 h. After cooling, dark wine red solution was obtained and kept, further, for 24 h in mother liquor for complete polymerization, (Scheme S1, ESI). The resulting product is CTet (Scheme 1).
image file: c5ra01845e-s1.tif
Scheme 1 Preparation of cyclic tetra[(indolyl)-tetra methyl]-diethane-1,2-diamine (CTet).

2.3. Functionalization of hydrous zirconium oxide with CTet

Aqueous solution of zirconium oxychloride (0.1 M) was warmed at 70 °C and hydrolyzed by drop wise addition of 0.1 M NaOH solution following the procedure reported in literature.32,33 The white gel formed was aged with supernatant for 2 days at room temperature. The obtained CTet solution was mixed with the HZO for 7 h with continuous stirring for complete impregnation of organic moieties. Finally the reaction mixture was filtered and precipitate was washed several times with water, and dried at 50 °C. The final product (CTet–HZO) was broken into small granules on treatment with distilled water. The chemical and elemental analysis of CTet–HZO shows the following composition: Zr = 19.18%, C = 50.50%, H = 5.09% and N = 11.78%. The functionalization of hydrous zirconium oxide with CTet is shown in Scheme 2.
image file: c5ra01845e-s2.tif
Scheme 2 Functionalization of HZO with cyclic tetra[(indolyl)-tetra methyl]-diethane-1,2-diamine (CTet) at optimal reaction condition.

2.4. Characterization of CTet–HZO

The Fourier transform infrared (FT-IR) spectra of HZO and CTet–HZO were recorded with Perkin Elmer FTIR spectrometer (Interspec 2020, Spectrolab, UK) using KBr pellet method. Far infrared spectra (FIR) were obtained by using a Perkin Elmer FT-IR/FIR Fourier spectrometer (wavenumber range 400 to 30 cm−1). The powder X-ray diffraction (XRD) analysis was done by the Panalytical's X'Pert Pro X-ray diffractometer. The radiation used is Cu Kα whereas nickel metal is used as beta filter. Scanning electron micrographs (SEM) coupled with EDX spectra of the material were taken by scanning electron microscope (JEOL JSM-6100 LV Tokyo, Japan), for surface morphology. Transmission electron micrograph (TEM) was also recorded using transmission electron microscope (JEOL JSM 2100, Japan). 13C NMR spectrum was recorded using Bruker Avance III spectrometer with solid state attachment CP-MAS (500 MHz). A Shimadzu TGA/DTA simultaneous measuring instrument, DTG-60/60H (Kyoto, Japan) was used for thermogravimetric analysis (TGA), differential thermal analysis (DTA) and differential scanning calorimetry (DSC) at a heating rate of 10 °C min−1 under nitrogen atmosphere. The concentration of fluoride was measured using expandable ion analyzer with the fluoride ion selective electrode (ELICO-LI126, India).

2.5. Batch adsorption experiments

Batch experiments were conducted by using the traditional bottle-point method to determine the fluoride adsorption equilibrium and kinetic properties of CTet–HZO. A 50 mL fluoride solution at a desired concentration level (20–900 mg L−1) was transferred to 100 mL polyethylene bottles. The pH of each solution was fixed at 3.5, except the influence of pH experiment. CTet–HZO (0.15 g) was added to the solution and agitated in an incubator shaker at 200 rpm. Effect of pH on the fluoride adsorption onto CTet–HZO and HZO was studied separately in the pH range 0.5–10 at an initial fluoride concentration of 20 mg L−1, maintaining the other parameters of the experiment constant.

Adsorption kinetics and thermodynamic studies were carried out by adding 0.15 g of CTet–HZO into a series of polyethylene bottles containing 50 mL solution with a fixed initial fluoride ion concentration (20 mg L−1) at pH 3.5 and different temperatures 308, 318 and 328 (±1) K. At a preselected time intervals, the samples were extracted from the polyethylene bottles. After each experiment, CTet–HZO particles were separated immediately by filtration through 0.45 μm membrane filter. Fluoride concentration of each filtrate was determined by ion analyzer using fluoride ion selective electrode. The amount of fluoride adsorbed at equilibrium (qe, mg g−1) was calculated by following equation:

 
image file: c5ra01845e-t1.tif(1)
where C0 and Ce are initial and equilibrium concentrations of fluoride (mg L−1), respectively, m is the mass of CTet–HZO (g) and V is volume of the solution (L).

2.6. Column experiments

Fixed bed column experiments were carried out by packing 0.83 g of CTet–HZO or HZO into two separate glass columns (1.0 cm in diameter and 25.0 cm length). The synthetic feeding solution was prepared by adding fluoride (5 mg L−1) to the tap water (free from fluoride) and was allowed to percolate through the column at a constant flow rate (2.5 mL min−1). To examine the feasibility of CTet–HZO and HZO for practical application, the groundwater and acidic industrial wastewater, collected from Agra and Aligarh districts of Uttar Pradesh, India, respectively, were also employed as the feeding solution. Percolation of sample solution was stopped when the concentration of fluoride in the effluent exceeded the permissible limit of 1.5 mg L−1.

3. Results and discussion

3.1. Physicochemical characterization of CTet–HZO adsorbent

FTIR spectrum of HZO (Fig. 1a) showed absorption bands at wave numbers 3355, 1622, 1556, 1447, 1412, 1130, 1080, 651 and 473 cm−1. The bands around 3355 and 1622 cm−1 are assigned to stretching and bending modes of coordinated water and O–H, respectively. The peak at 1130 cm−1 is assigned to the bending vibration of hydroxyl group of Zr–OH.34 The band at 651 is assigned to Zr–O linkage.35 FT-IR spectrum (Fig. 1b) shows absorption bands at 3410 and 1619 cm−1 are due to –N–H stretching and bending vibrations. In these regions, the coordinated water molecules also absorb radiation. The band appearing at 2928 cm−1 may be assigned to –C–H stretching vibration of methylene group. The presence of C–N stretching absorption of primary aliphatic amine is confirmed by the band at 1087 cm−1. The band peaking at 1458 cm−1, 1412 and 1344 cm−1 may be assigned to –C[double bond, length as m-dash]C in-plane vibration and C[double bond, length as m-dash]N stretching vibration of indole.35 Another peak at 744 cm−1 is attributed to ortho-disubstituted benzene.35 Far IR spectra of CTet–HZO and fluoride adsorbed CTet–HZO are presented in ESI (Fig. S1a and b). CTet–HZO in Cl form shows absorption bands at 229.33, 180, 155 & 104 cm−1; while fluoride sorbed CTet–HZO shows strong bands at 290, 200, 157, 120, 96 and 48 cm−1. The peak at 104 disappeared suggested the sorption of fluoride on CTet–HZO.36 The two strong absorption bands (both spectra) at 324 cm−1 and 229 cm−1 are due to the N–Zr–N in plane bending.34
image file: c5ra01845e-f1.tif
Fig. 1 FT-IR spectra: (a) hydrous zirconium oxide, (b) modified hydrous zirconium oxide (CTet–HZO).

The X-ray diffraction patterns of the adsorbent before and after fluoride adsorption are shown in Fig. 2. XRD study reveals the amorphous nature of CTet–HZO with some change after the adsorption of fluoride ions. The fluoride ion sorbed material showed peak at 29.61 with d-spacing of 1.49 Å. SEM images of HZO, CTet–HZO and fluoride sorbed CTet–HZO are shown in Fig. 3a–c. HZO (Fig. 3a) showed the agglomerated surface morphology with irregular shape and porous nature. SEM image of CTet–HZO showed some changes in the surface morphology owing to incorporation of CTet. The surface of the adsorbent before and after fluoride adsorption seems to be more or less similar. However, EDX spectrum (Fig. S2, ESI) confirmed the presence of fluoride on the adsorbent surface. TEM image of CTet–HZO is shown in Fig. 4. The particles of CTet–HZO have irregular shape and very broad in size distribution ranging from 60.5–189 nm. Fig. 5 shows 13C NMR spectrum of CTet–HZO. The chemical shifts observed at 137.19 ppm, 128.70 ppm, 120.30 ppm and 110.53 ppm indicated the presence of C[double bond, length as m-dash]C, aromatic carbon, –C– on ortho position of benzene ring, and aryl carbon, respectively. The chemical shifts at 64.03 ppm and 55.14 ppm indicated the presence of C–N linkage and –CH aliphatic, respectively. The peaks at 32.87 & 30.62 ppm confirmed the –CH2 group. Tertiary alkyl carbon appears at 15.48 ppm while the shift at 21.04 ppm suggested the presence of C at 3 position of pyrrole.


image file: c5ra01845e-f2.tif
Fig. 2 X-ray diffraction pattern (a) CTet–HZO (b) fluoride sorbed CTet–HZO.

image file: c5ra01845e-f3.tif
Fig. 3 SEM images: (a) hydrous zirconium oxide (b) CTet–HZO and (c) fluoride sorbed CTet–HZO.

image file: c5ra01845e-f4.tif
Fig. 4 TEM image of CTet–HZO.

image file: c5ra01845e-f5.tif
Fig. 5 13C NMR spectrum of CTet–HZO.

The results of thermal analysis of HZO and CTet–HZO are presented in Fig. 6a and b. TGA curve of HZO indicated the weight loss in the temperature range of 30 to 350 °C and was attributed to dehydration of the interstitial water.37,38 DTA curve showed one endothermic peak at 75 °C, indicating the loss of water molecules. In case of CTet–HZO, the weight loss occurred in two steps; 16.94% and 15.51% from 40–190 °C and >190–440 °C, respectively, corresponding to physically adsorbed water and dehydroxylation from OH groups. The DTA curve showed an endothermic peak at 72.41 °C. However, on increasing the temperature above 440 °C, sharp deflections in the TGA curve was observed which is attributed to the decomposition of organic molecule present in the matrix. The DTA curve showed an exothermic peak at 450 °C which also confirmed the decomposition of organic molecule and two step weight loss. DSC curve of CTet–HZO (Fig. S3, ESI) showed an endothermic peak at 96 °C which also confirmed the loss of water molecules.


image file: c5ra01845e-f6.tif
Fig. 6 TGA and DTA curves (a) HZO and (b) CTet–HZO material.

3.2. Adsorption of fluoride on CTet–HZO

3.2.1. Effect of pH, contact time and sorption mechanism. The pH of the aqueous system is one of the most important parameters which directly affect the fluoride adsorption process. Fig. 7 shows the effect of pH on the fluoride uptake by CTet–HZO at 308 ± 1 K. Results indicated that the maximum adsorption of fluoride occurred in the pH range 3.5–4.5. Fluoride has different species in water,39 including HF, HF2 and F. The pKa of hydrofluoric acid is 3.18 and therefore, free fluoride ions are available for ligand exchange/hydrogen bonding at pH > 3.18. At pH 3.5, OH groups attached to Zr(IV) are protonated and thus promote the adsorption of F ions. On the other hand, at pH < 3.5 uptake of fluoride decreased that may be due to the non-availability of free fluoride ions. At higher pH, the decrease in uptake of fluoride ions may be attributed to the presence of OH which caused the deprotonation of the OH2+ groups in the structure. Under this condition the fluoride ions are repelled through electrostatic repulsion. This trend is similar to fluoride ion retention on polystyrene anion exchanger supported hydrous zirconium oxide nanoparticle.40 The effect of pH on the uptake of fluoride by HZO was also studied. The maximum adsorption was observed in the pH range 6–7 (Fig. S4, ESI). The adsorption of fluoride on CTet–HZO (pH 3.5) and HZO (pH 6.5) was studied as a function of contact time. Results (Fig. S5 and S6, ESI) indicated that the adsorption equilibrium was attained in 40 min with CTet–HZO whereas 90 min are needed for HZO.
image file: c5ra01845e-f7.tif
Fig. 7 Effect of pH variation. Concentration; 20 mg L−1; contact time; 40 min; adsorbent dose; 0.15 g.

The effect of solution pH on the stability of CTet–HZO was studied. It was observed that the leaching of Zr(IV) occurred at pH < 2.6. At pH 2.8, 0.08% Zr(IV) and 0.11% cyclic diamine of CTet–HZO were leached into the surrounding solution when immersed for three days. However, Zr(IV) and cyclic diamine were not detected in the residual solution when pH was above 3.0, suggesting the stability of the CTet–HZO.

Recent 1H-NMR study30 suggested that indole NHs interact with fluoride ion through hydrogen bonding. In our study, CTet–HZO possesses four indole-NH groups and providing four binding sites for fluoride ion which is indicative of enhanced fluoride sorption. The adsorption mechanism is shown in Scheme 3.


image file: c5ra01845e-s3.tif
Scheme 3 Sorption mechanism of fluoride onto CTet–HZO.

The effect of the increased adsorbent dosage on the percent removal of fluoride was studied by varying the amount of adsorbent dose from 0.05–0.4 g/50 mL. The experiment was carried out using initial fluoride ion concentration of 20 mg L−1 at pH 3.5, keeping the contact time of 40 min. Results (Fig. S7, ESI) revealed that the removal efficiency increased with increase in adsorbent dose and the value reaches a maximum (98.67%) corresponding to a feeding dose of 0.15 g. The observed results could be attributed to increase in surface area with increase in adsorbent dose and hence more adsorption sites are available for fluoride adsorption.

It is well known that the common ions such as Cl, NO3, SO42−, HCO3, CO32−, and PO43− are ubiquitous in drinking water and wastewater. These ions can compete for adsorption sites and decrease the removal efficiency of the adsorbent. Fluoride adsorption in presence of potential co-existing ions was studied to elucidate the outstanding selectivity of CTet–HZO. Hence the tests were conducted in the presence of co-existing ions in the broad range of concentrations (1–1000 mg L−1) and results are shown in Fig. 8. It is evident from the figure that the removal efficiency of F is not affected in presence of these co-existing ions. However, presence of arsenate ion decreases the removal efficiency of fluoride ion.


image file: c5ra01845e-f8.tif
Fig. 8 Bar diagram showing the percentage uptake of fluoride ion in presence of interfering ions.

3.3. Sorption studies and modelling

For optimization of the process for fluoride removal, it is important to understand fluoride ion distribution between two phases via analyzing the adsorption equilibrium data. In this study, the equilibrium data obtained for initial fluoride ion concentration variation from 100 to 700 mg L−1 at pH 3.5 were investigated by Langmuir, Freundlich and Temkin adsorption isotherm models. The significance of isotherm equations has been highlighted in a number of research articles.41

The linear form of Langmuir adsorption isotherm42 equation is expressed as:

 
image file: c5ra01845e-t2.tif(2)
where qe is the amount of solute adsorbed per unit weight of adsorbent (mg g−1) and Ce is the equilibrium concentration in solution (mg L−1). The values of qm and KL, (Langmuir isotherm constant) relate to the monolayer adsorption capacity (mg g−1) and energy of adsorption process. The plots between 1/qe and 1/Ce at different initial concentrations and temperatures generate straight line (Fig. 9a). The isotherm parameters were calculated and represented in Table 1. The maximum adsorption capacity of CTet–HZO was found to be 188.6 mg g−1.


image file: c5ra01845e-f9.tif
Fig. 9 Equilibrium adsorption isotherms of F onto CTet–HZO (a) Langmuir model (b) Freundlich model (c) Temkin model.
Table 1 Isotherm parameters of Langmuir, Freundlich and Temkin models for the adsorption of fluoride onto CTet–HZO at different temperatures
Isotherm Temperature (K) Parameters Error function
qm (mg g−1) KL R2 APE
Langmuir 308 333.33 0.010 0.993 11.18
318 204.08 0.020 0.991 4.5
328 196.07 0.021 0.980 2.31

Isotherm Temperature (K) Parameters Error function
qm (mg g−1) Kf n R2 APE
Freundlich 308 185.4 6.69 1.48 0.988 0.463
318 183.48 9.66 1.65 0.991 0.486
328 188.68 15.31 1.93 0.995 0.11

Isotherm Temperature (K) Parameters Error function
qm (mg g−1) bT AT R2 APE
Temkin 308 167.73 44.46 0.133 0.939 1.46
318 168.21 49.40 0.191 0.925 1.63
328 169.60 60.07 0.335 0.930 1.61


The performance of CTet–HZO for fluoride adsorption was compared with some previously prepared adsorbents and hydrous zirconium oxide (HZO) prepared in this study (Table 2). The comparative data indicated the superiority of our material over others, mainly in terms of adsorption capacity and contact time. For example, modified carbon nanotubes (CNTs)46 and graphene (GO)51 show sorption capacity of 15 mg g−1 and 48.31 mg g−1, respectively. These materials are costly and also a large-scale application of CNTs and GO is limited because of its comparatively higher operational cost. In this reference, CTet–HZO was found to be cheap, efficient and also highly selective adsorbent with high sorption capacity (188.68 mg g−1) for fluoride ion.

Table 2 Comparison of fluoride adsorption capacities and equilibrium time of different adsorbents reported in the literature with present study
Sorbents Equilibrium time Fluoride adsorption capacity (mg g−1) pH Reference
Aligned carbon nanotubes 1 h 3.0 7.0 43
Aluminium modified hematite 24 h 10.3 6.2 44
CeO2–ZrO2 nanocages 24 h 175 4.0 45
Al2O3/CNTs 14.9 6.0 46
Al3+-exchanged zeolite 24 h 37.5 6.5 47
CTAB mediated Mg-doped nano Fe2O3 4 h 49.2 7.0 48
Hydrous ferric oxide doped alginate beads 1.5 h 8.9 7.0 49
Hydrous Ce(IV)–Zr(IV) mixed oxide 1.5 h 19.5 5.8 50
Graphene 110 min 48.3 3.6–10.2 51
Hydrous zirconium oxide 45 min 124, 68 4.0, 7.0 33
Hydrous zirconium oxide (HZO) 90 min 54.6 6–7 This study
CTet–HZO 40 min 188.6 3.5–4.5 This study


Langmuir isotherm criterion52 can be described in term of dimensionless constant which is known as separation factor, RL which can be defined as:

 
image file: c5ra01845e-t3.tif(3)
where C0 is the initial concentration of fluoride ion (mg L−1). The feasibility of adsorption can be predicted from the values of RL. For a favourable adsorption, the condition is: 0 < RL < 1. In the present investigation, the values of RL were found to be between 0 and 1 at all the temperatures studied which indicated the adsorption of fluoride onto CTet–HZO is a favourable process.

The linear form of the Freundlich equation is defined as:53

 
image file: c5ra01845e-t4.tif(4)
where Kf represents the adsorption capacity constant and 1/n is related to the adsorption intensity. The values of Kf and n were calculated from the intercept and slope of the plot of log[thin space (1/6-em)]qe against log[thin space (1/6-em)]Ce (Fig. 9b) and summarized in Table 1. The values of Kf increased with increasing temperatures from 308 to 328 K, indicating that the adsorption processes were endothermic in nature. In general, the value of n > 1 indicates a favourable sorption process54 and higher the n value stronger the adsorption intensity.55 In the present investigation, the values of n were found to be 1.48, 1.65, and 1.93 at 308, 318 and 328 K, respectively, which indicated the adsorption of fluoride onto CTet–HZO is favourable. The increase of n value with the increase in temperature suggested increase in adsorption intensity and endothermic nature of the adsorption process.56

The application of Temkin isotherm57 model is based on the assumptions: (i) adsorption process is characterized by uniform distribution of binding energies; (ii) a linear relationship exists between adsorbate–adsorbent interactions with a decrease of heat of adsorption for all the molecules covered in a layer. The linear form of Temkin equation is expressed as:

 
qe = β[thin space (1/6-em)]ln[thin space (1/6-em)]AT + β[thin space (1/6-em)]ln[thin space (1/6-em)]Ce (5)

image file: c5ra01845e-t5.tif
where AT is the equilibrium binding constant corresponding to the maximum binding energy (L mg−1), bT is Temkin isotherm constant related to heat of adsorption (J mol−1). The values of AT and bT can be obtained from the intercept and slope of the plots of qe vs. ln[thin space (1/6-em)]Ce (Fig. 9c) and reported in Table 1.

The average percentage error (APE) analysis was used for comparison of all isotherm models using the following equation:

 
image file: c5ra01845e-t6.tif(6)
here, qe,cal and qe,exp represent the equilibrium capacity calculated from the isotherm models (mg g−1), and equilibrium capacity from the experimental data. The values of APE of each model are presented in Table 1.

On the basis of coefficient of determination (r2 > 0.998) and low values of APE, it can be suggested that experimental data fit well with Freundlich isotherm model followed by Temkin and Langmuir models. Similar observations on applicability of the experimental data to Freundlich model have been reported for adsorption of fluoride by alginate based anion exchanger,58 Zr–Mn composite materials59 and chitosan bead.60

3.4. Thermodynamic feasibility of the process

The thermodynamic parameters such as change in free energy (ΔG°), enthalpy (ΔH°) and entropy (ΔS°) were calculated using the following equations;
 
ΔG° = −RT[thin space (1/6-em)]ln[thin space (1/6-em)]Kc (7)
 
log[thin space (1/6-em)]Kc = ΔS°/2.303R − ΔH°/2.303RT (8)
where,
Kc = qe/Ce
Kc is the equilibrium constant, R the universal gas constant (8.314 J mol−1 K−1), and T the absolute temperature (K). The Vant's Hoff plot (log[thin space (1/6-em)]Kc against 1/T; Fig. 10) gave a straight line and the values of ΔH° and ΔS° were evaluated from the slope and intercept. The values of ΔH° and ΔS° were found to be 4.98 kJ mol−1 and 18.43 J mol−1 K−1, respectively. The values of ΔG° were −6.98, −8.82 and −10.66 kJ mol−1 at 308, 318 and 328 K, respectively. The results illustrate that the fluoride adsorption on CTet–HZO surface is spontaneous and endothermic in nature.

image file: c5ra01845e-f10.tif
Fig. 10 Van't Hoff plot for adsorption of fluoride onto CTet–HZO.

3.5. Adsorption kinetics

Kinetic behaviour of CTet–HZO towards fluoride adsorption was studied as a function of time at a fixed initial concentration of fluoride ion (20 ppm) and at temperatures 308, 318 and 328 K. The time-dependent adsorption data were interpreted by pseudo-first order, pseudo-second-order and intraparticle diffusion models.

The linear form of pseudo-first order kinetic model61 is expressed as:

 
image file: c5ra01845e-t7.tif(9)
where k1 is the rate constant of the pseudo-first-order adsorption process (min−1), qe and qt are the amount of fluoride adsorbed at equilibrium and at time t (mg g−1), respectively. A plot of log(qeqt) against time yielded a straight line (Fig. S8; ESI) and the rate constant k1 was evaluated from the slope (Table 3).

Table 3 Adsorption kinetic parameters of different models
Temp. K Pseudo-first-order or Lagergren model Pseudo-second-order model Intra particle diffusion model
qe,exp k1 qe,cal R2 APE k2 qe,cal APE kid C R2
308 4.35 0.257 18.1 0.913 105 0.0627 4.69 2.6 0.021 0.193 0.883
318 4.85 0.310 25.0 0.867 138.4 0.0453 4.85 0 0.104 0.499 0.909
328 4.93 0.274 11.3 0.917 43.06 0.0379 5.05 0.81 0.148 2.055 0.921


The linear form of pseudo second order kinetic model62 is given by the following equation:

 
t/qt = 1/k2qe2 + 1/qet (10)
where k2 is the rate constant for the pseudo-second order adsorption reaction (g mg−1 min−1). The value of k2 and qe were evaluated from the slope and intercept of the linear plot of t/qt versus t (Fig. S8; ESI) and results are reported in Table 3. The applicability of a particular kinetic model for CTet–HZO–fluoride system was examined on the basis of correlation coefficient values (R2) and average percentage error (APE). As can be seen from the table that pseudo second order model with higher values of correlation coefficient and lower values of APE can accurately describe the experimental data.

3.5.1. Intraparticle diffusion. The adsorption of an adsorbate onto an adsorbent can occur in three consecutive steps: (i) film diffusion, (ii) intra-particle diffusion, and (iii) adsorption on the interior surface of the adsorbent. The possible contribution of intraparticle diffusion on fluoride adsorption was investigated by a model given by Weber and Morris63 which is expressed as:
 
qt = kidt0.5 + Ci (11)
where kid is the intraparticle diffusion rate constant (mg g−1 min0.5) and Ci is the intraparticle diffusion constant, which is directly proportional to the boundary layer thickness. According to Weber and Morris model, the plots of qt versus t0.5 should be linear if intraparticle diffusion is involved and if the lines pass through the origin, then the intraparticle diffusion is the rate controlling step.63,64 When the plots do not pass through the origin, then some degree of boundary layer control is suggested. If the data exhibit multi-linear plots, then two or more steps influence the sorption process.49,63–65 Therefore, to decide on the main rate limiting step, qt was plotted against t0.5 for the sorption of fluoride on CTet–HZO (Fig. 11). As can be seen from figure that the first region would describe the external resistance to mass transfer that is boundary layer diffusion. The second region is being dominated by intraparticle diffusion, where intraparticle diffusion is the rate-controlling step. In the last region, the intraparticle diffusion starts to go slow, owing to the decrease in the fluoride concentration in the aqueous phase, as well as decrease in the active sites available for adsorption. Similar observations were reported for fluoride adsorption by Mg–Al-LDHs nanoflakes.56 The values of kid, Ci, and the correlation coefficients corresponding to the second region of the linear fitting of the kinetic data are listed in Table 3. The value of Ci and kid increases with increase in concentration which reflects the boundary layer effect. The high value of R2 indicated that the intra-particle diffusion played a significant role in the sorption of fluoride onto CTet–HZO hybrid material. Based on these results it might be concluded that the intra-particle diffusion was not the only rate controlling step in the sorption of fluoride onto the CTet–HZO hybrid material. Therefore the adsorption process may be consisting of both the surface adsorption and intraparticle diffusion.

image file: c5ra01845e-f11.tif
Fig. 11 Plot of qt versus t0.5 for the sorption of fluoride ion onto CTet–HZO at different temperatures.

3.6. Application

Three groundwater samples (GW-1, GW-2 and GW-3), acidic effluent from metal finishing industry (AE) and river water sample (Ganga River) were collected from Aligarh (GW-1, GW-2 and AE), Agra (GW-3) and Kanpur districts of U.P., India respectively. The physico chemical analysis of water samples is given in (Table S1; ESI). CTet–HZO was used to remove fluoride from the water samples (GW-1, GW-2 and river water) by batch method. The pH of water sample (50 mL) was adjusted to 3.5 using HNO3 before applying to CTet–HZO. A predetermined amount of CTet–HZO was added to each sample. After 40 min of equilibration, the samples were filtered and fluoride ion concentration was determined. The results are reported in Table 4. As can be seen from the table that the removal of fluoride in different water samples was above 90% which proved that the CTet–HZO has a promising application for water treatment.
Table 4 Removal of fluoride ion from water samples collected from different sources using CTet–HZO by batch methodb
Sample no. Permissible limit (mg L−1) Initial fluoride ion concentration (μg mL−1) Fluoride ion concentration after adsorption (μg mL−1) RSD (%) Removal (%)
a WHO = World Health Organization.b RW = river water.
GW-1 1.5/WHOa 1.84 0.067 5.90 96.46
GW-2 1.5/WHO 3.62 0.056 1.79 98.45
RW 1.5/WHO 2.68 0.142 1.69 94.70


The fixed bed column adsorption experiments were conducted to evaluate the applicability of CTet–HZO and HZO in the removal of fluoride from synthetic water sample, groundwater (GW-3) and acidic effluent of metal finishing industry (AE). The basic composition of feeding solutions were shown in ESI Table S2. Results (Fig. 12) indicated that the effective treatable volume of synthetic water sample, groundwater and acidic effluent with CTet–HZO were around 160 mL, 180 mL and 320 mL, respectively, when the breakthrough point was set as 1.5 mg L−1. The treatable volumes of synthetic water sample, groundwater and acidic effluent with HZO reached upto 105 mL, 120 mL and 30 mL, respectively (Fig. S9, ESI). The Zr(IV) and diamine were not detected in the treated water. The results have suggested that CTet–HZO is more efficient than HZO in removing the fluoride from groundwater and acidic effluent of metal finishing industry.


image file: c5ra01845e-f12.tif
Fig. 12 Removal of fluoride from different feeding solution by column method using CTet–HZO as sorbent (a) synthetic water sample, fluoride concentration = 5.0 mg L−1; pH 6.8 (b) groundwater (GW-3), fluoride concentration = 3.6 mg L−1; pH 6.8 (c) acidic effluent (AE), fluoride concentration = 4.20 mg L−1; pH 4.1.

3.7. Reuse and regeneration of CTet–HZO

Regeneration and reuse of adsorbent materials is particularly required to reduce the cost factor. Desorption of fluoride from fluoride loaded CTet–HZO was carried out at varying concentrations of NaOH. It was observed that leaching of fluoride from the adsorbent material increased from 15.2% to 98.67% with increasing NaOH concentration from 0.02 to 0.1 M. Further addition of increased NaOH concentration did not improve the leaching of F from the adsorbent. Hence, 0.1 M NaOH was used as a suitable desorbing agent. The adsorption of fluoride onto CTet–HZO followed by desorption with 0.1 M NaOH solution up to 10 cycles was studied. Results (Fig. 13) show that adsorption (%) of fluoride on the regenerated materials was negligibly affected up to 4 cycles but percent adsorption gradually decreased from 98.67% to 91.2% with increasing regeneration cycles from 4 to 10. The study suggested that the material can be effectively used for removal of fluoride from aqueous system.
image file: c5ra01845e-f13.tif
Fig. 13 Bar diagram showing the percentage uptake of fluoride by CTet–HZO in different cycles of batch operation.

4. Conclusion

In summary, we have prepared cyclic tetra[(indolyl)-tetra methyl]-diethane-1,2-diamine (CTet) impregnated hydrous zirconium oxide. The synthesis was done in three steps.

• Firstly hydrous zirconium oxide gel was prepared.

• Secondly, cyclic tetramer of indole (CTet) was prepared by involving Mannich base.

• Finally, CTet was incorporated into the hydrous zirconium oxide.

I. The fluoride adsorption capacity was found to be 188.68 mg g−1. The enhanced capacity was mainly due to interaction between indole-NHs and fluoride ions.

II. The experimental adsorption data were analyzed by Langmuir, Freundlich and Temkin isotherm models. The coefficient of determination (R2) and APE values indicated that Freundlich model describes the best fit of experimental data.

III. The adsorption of fluoride onto CTet–HZO follows the pseudo second order kinetic model.

IV. The thermodynamic parameters (ΔG < 0; ΔH > 0) suggest the sorption process is spontaneous & endothermic in nature. The remarkable advantage of this material is its chemical and mechanical stability due to the host organic molecule during successive sorption–desorption cycles.

V. CTet–HZO was found to be more effective than HZO for remediation of fluoride from drinking water.

Acknowledgements

The authors are thankful to UGC (DRS-II) and DST (FIST and PURSE) for facilities to carry out this work. Uzma Haseen and Mohammad Fazeel Khan are grateful to UGC for providing financial support to complete the research work. We are also thankful to USIF, A.M.U. Aligarh for SEM and TEM; SAIF, Punjab University, Chandigarh for XRD.

References

  1. I. Pauling, The nature of chemical bond, Cornell university press Ithaca, New York, 3rd edn, 1960 Search PubMed.
  2. J. Fawell, K. Bailey, J. Chilton, E. Dahi, L. Fewtrell and Y. Magara, Fluoride in drinking water, World Health Organisation, IWA Publishing, London, UK, 2006, p. 5 Search PubMed.
  3. R. Tekle-Haimanot, Z. Melaku, H. Kloos, S. Reimann, W. Fantye, L. Zerihun and K. Bajorvatn, Sci. Total Environ., 2006, 367, 182–190 CrossRef CAS PubMed.
  4. M. Amini, K. Mueller, K. C. Abbaspour, T. Rosenberg, M. Afyuni, K. N. Moller, M. Sarr and C. A. Johnson, Environ. Sci. Technol., 2008, 42, 3662–3668 CrossRef CAS.
  5. WHO, Fluoride and oral health. Report of a WHO expert committee on oral health status and fluoride use, WHO Technical Report Series, No. 846; Geneva, 1994 http://whqlibdoe.who.int/trs/WHO_TRS_846.pdf.
  6. P. E. Petersen and M. A. Lennon, Community Dentistry and Oral Epidemiology, 2004, 32, 319–322 CrossRef PubMed.
  7. United State Environmental Pollution Agency (USEPA), National primary drinking water standards, EPA/816-F/03/016, 2003.
  8. WHO, Guidelines for drinking water quality, World health Organisation, Geneva, Switzerland, 3rd edn, 2004 Search PubMed.
  9. C. Gonzales, H. Hotokezaka, E. I. Karadeniz, T. Miyazaki, E. Kobayashi, M. A. Darendeliler and N. Yoshida, Am. J. Orthod., 2004, 139, 196–205 CrossRef PubMed.
  10. I. B. Solangi, S. Memon and M. I. Bhanger, J. Hazard. Mater., 2009, 171, 815–819 CrossRef CAS PubMed.
  11. Rajiv Gandhi National Drinking Water Mission (RGNDWM), Prevention and control of fluorosis in India, 1993 Search PubMed.
  12. S. S. Tripathi, J. Bersillon and K. Gopal, Sep. Purif. Technol., 2006, 50, 310–317 CrossRef PubMed.
  13. M. F. Chang and J. C. Liu, J. Environ. Eng., 2007, 133, 419–425 CrossRef CAS.
  14. L. A. B. S. Richards, H. M. A. Rossiter and A. I. Schafer, Desalination, 2009, 248, 177–183 CrossRef CAS PubMed.
  15. S. Chakrobortty, M. Roy and P. Pal, Desalination, 2013, 313, 115–124 CrossRef PubMed.
  16. A. N. Ghanim, Int. J. Environ. Sci., 2014, 4, 660–675 CAS.
  17. M. Arda, E. Orhan, O. Arar, M. Yusksel and N. Kabay, Sep. Sci. Technol., 2009, 44, 841–853 CrossRef CAS.
  18. A. Bhatnagar, E. Kumar and M. Sillanpaa, Chem. Eng. J., 2011, 171, 811–840 CrossRef CAS PubMed.
  19. J. Qiao, Z. Cui, Y. Sun, Q. Hu and X. Guan, Environ. Sci. Eng., 2014, 8, 169–179 CAS.
  20. M. Mohapatra, D. Hariprasad, L. Mohapatra, S. Anand and B. K. Mishra, Appl. Surf. Sci., 2012, 258, 4228–4236 CrossRef CAS PubMed.
  21. T. Wajima, Y. Umeta, S. Narita and K. Sugawara, Desalination, 2009, 249, 323–330 CrossRef CAS PubMed.
  22. S. K. Swain, T. Patnaik and R. K. Dey, Desalin. Water Treat., 2013, 51, 4368–4378 CrossRef CAS.
  23. A. L. Srivastava, P. K. Singh, V. Srivastava and Y. C. Sharma, J. Hazard. Mater., 2013, 263, 342–352 CrossRef PubMed.
  24. M. R. Boldaji, A. H. Mahvi, S. Dobaradaran and S. S. Hosseini, Int. J. Environ. Sci. Technol., 2009, 6, 629–632 CrossRef CAS.
  25. R. K. Dey, S. K. Swain and T. Patnaik, ARPN Journal of Science and Technology, 2012, 2, 138–142 Search PubMed.
  26. Q. Zhang, Q. Du, T. Jiao, Z. Zhang, S. Wang, Q. Sun and F. Gao, Sci. Rep., 2013, 3, 2551,  DOI:10.1038/srep02551 , 1–9.
  27. M. D. Santi, L. Galluzi, S. Lucarini, M. F. Poletti, A. Fraternale, A. Duranti, C. D. Marco, M. Fanilli, N. Zaffaroni, G. Brandi and M. Magnani, Breast Cancer Res. Treat., 2011, 13, 1–15 Search PubMed.
  28. M. D. Santi, A. Antonelli, M. Menotta, C. Sfara, S. Sarafini, S. Lucarini, G. Brandi and M. Magnani, Journal of Nanopharmaceutics and Drug Delivery, 2013, 1, 45–51 CrossRef PubMed.
  29. M. K. Suk, N.-K. Chae, U.-I. Kim, J.-M. Kim and K.-S. Jeong, Pure Appl. Chem., 2008, 80, 599–608 CrossRef.
  30. B. Deka and R. J. Sarma, Sens. Actuators, A, 2014, 197, 321–325 CrossRef CAS PubMed.
  31. R. R. Gupta, M. Kumar and V. Gupta, Heterocyclic chemistry, Springer (India) Pvt. Limit., New Delhi, Springer international Edition, 2005, vol. II, pp. 226–228 Search PubMed.
  32. K. Biswas, D. Bandhoyapadhay and U. C. Ghosh, Adsorption, 2007, 13, 83–94 CrossRef CAS PubMed.
  33. X. Dou, D. Mohan, U. Charles Pittman Jr and S. Yang, Chem. Eng. J., 2012, 199, 236–245 CrossRef PubMed.
  34. K. Nakamoto, Infrared and Raman spectra of Inorganic and Co-ordination compounds, Part B, John Wiley & sons inc. Publication, 6th edn, 2009, pp. 16–17 Search PubMed.
  35. G. Socrates, Infrared Characteristics Group Frequencies, John Wiley & Sons, New York, 3rd edn, 1980 Search PubMed.
  36. J. T. R. Dunsmuir and A. P. Lane, Spectrochim. Acta, Part A, 1972, 28, 45–50 CrossRef CAS.
  37. H. F. Castro, M. L. C. P. Silva and G. L. J. P. Silva, Braz. J. Chem. Eng., 2000, 17, 849–857 CrossRef CAS PubMed.
  38. C. Hang, Q. Li, S. Gao and J. K. Shang, Ind. Eng. Chem. Res., 2012, 51, 353–361 CrossRef CAS.
  39. Y. Tang, J. Wang and N. Gao, J. Environ. Sci., 2010, 22, 1689–1694 CrossRef CAS.
  40. B. Pan, J. U. B. Wu, Z. Li and X. Liu, Environ. Sci. Technol., 2013, 47, 9347–9354 CrossRef CAS PubMed.
  41. N. Rahman and U. Haseen, Ind. Eng. Chem. Res., 2014, 53, 8198–8207 CrossRef CAS.
  42. I. Langmuir, J. Am. Chem. Soc., 1918, 40, 1361–1403 CrossRef CAS.
  43. Y.-H. Lia, S. Wang, X. Zhanga, J. Weia, C. Xua, Z. Luanb and D. Wua, Mater. Res. Bull., 2003, 38, 469–476 CrossRef.
  44. A. T. Sequeira, M. S. Rios, V. M. Miranda and I. L. Hernandez, J. Colloid Interface Sci., 2014, 418, 254–260 CrossRef PubMed.
  45. J. Wang, W. Xu, L. Chen, Y. Jia, L. Wang, X.-J. Huang and J. Liu, Chem. Eng. J., 2013, 231, 198–205 CrossRef CAS PubMed.
  46. Y.-H. Li, S. Wang, A. Cao, D. Zhao, X. Zhang, C. Xu, Z. Luan, D. Ruan, J. Liang, D. Wu and B. Wei, Chem. Phys. Lett., 2001, 350, 412–416 CrossRef CAS.
  47. M. S. Onyango, Y. Kojima, O. Aoyi, E. C. Bernardo and H. Matsuda, J. Colloid Interface Sci., 2004, 279, 341–350 CrossRef CAS PubMed.
  48. M. Mohapatra, T. Padhi, S. Anand and B. K. Mishra, Desalin. Water Treat., 2012, 50, 376–386 CrossRef CAS.
  49. M. G. Sujana, A. Mishra and B. C. Acharya, Appl. Surf. Sci., 2013, 270, 767–776 CrossRef CAS PubMed.
  50. G. Chakrabarti, S. K. Biswas and U. C. Ghosh, Appl. Surf. Sci., 2014, 307, 665–676 CrossRef PubMed.
  51. Y. Li, P. Zhang, Q. Du, X. Peng, T. Liu, Z. Wang, Y. Xia, W. Zhang, K. Wang, H. Zhu and D. Wu, J. Colloid Interface Sci., 2011, 363, 348–354 CrossRef CAS PubMed.
  52. K. R. Hall, L. C. Eagletow, A. Acrivers and T. Vermenlem, Ind. Eng. Chem. Fundam., 1966, 5, 212–223 CAS.
  53. H. M. F. Freundlich, J. Phys. Chem., 1906, 57, 385–470 CAS.
  54. G. Jayapriyal, R. Ramya, X. R. Rathinam and P. N. Sudha, Arch. Appl. Sci. Res., 2011, 3, 415–423 Search PubMed.
  55. J. U. K. Oubagaranadin, N. Sathyamurthy and Z. V. P. Murthy, J. Hazard. Mater., 2007, 142, 165–174 CrossRef CAS PubMed.
  56. C. Gao, X.-Y. Yu, T. Luo, Y. B. Jia, J. Sun, H. Liu and X. J. Huang, J. Mater. Chem. A, 2014, 2, 2119–2128 CAS.
  57. R. D. Johnson and F. H. Arnold, Biochim. Biophys. Acta, 1995, 1247, 293–297 CrossRef.
  58. H. Paudyal, B. Pangeni, K. Inou, H. Kawakita, K. Ohto, K. N. Ghimire and S. Alam, Bioresour. Technol., 2013, 148, 221–227 CrossRef CAS PubMed.
  59. V. Tomar, S. Prasad and D. Kumar, Microchem. J., 2013, 111, 116–124 CrossRef CAS PubMed.
  60. N. Viswanathan, C. S. Sundaram and S. Meenakshi, J. Hazard. Mater., 2009, 161, 423–430 CrossRef CAS PubMed.
  61. S. Lagergren, K. Sven. Vetenskapsakad. Handl., 1898, 24, 1–39 Search PubMed.
  62. Y. S. Ho and G. Mckay, Can. J. Chem. Eng., 1998, 76, 822–827 CrossRef CAS PubMed.
  63. J. W. J. Weber and J. C. Morris, J. Sanit. Eng. Div., Am. Soc. Civ. Eng., 1963, 89, 31–60 Search PubMed.
  64. N. Chen, Z. Zhang, C. Fang, N. Sugiura, M. Li and R. Chen, J. Colloid Interface Sci., 2010, 348, 579–584 CrossRef CAS PubMed.
  65. M. J. Yu, F. Zhou, L. Jin, L. Yang, M. Luan, J. Tang, Y. Fan, H. Yuan and Z. J. Chen, ACS Appl. Mater. Interfaces, 2012, 4, 5749–5760 Search PubMed.

Footnote

Electronic supplementary information (ESI) available. See DOI: 10.1039/c5ra01845e

This journal is © The Royal Society of Chemistry 2015
Click here to see how this site uses Cookies. View our privacy policy here.