Bomi Sim and
Hyoung Jin Choi*
Department of Polymer Science and Engineering, Inha University, Incheon, 402-751, Korea. E-mail: hjchoi@inha.ac.kr
First published on 12th January 2015
Polyaniline (PANI) nanotubes were fabricated successfully using a micelle soft-template method in the presence of oxalic acid as a dopant and applied as the dispersed phase of an electrorheological (ER) fluid. The obtained nanotubes were on average 110 nm in external diameter and 10 nm in internal diameter, and several micrometers in length. The X-ray diffraction pattern confirmed the crystalline structure of PANI owing to its tubular morphology. The rheological characteristics of the flow curves and yield stress of its ER fluid when dispersed in silicone oil were examined using a rotational rheometer equipped with a high voltage generator. Under an electric field, the PANI nanotubes showed improved ER effects, confirming that elongated particles have enhanced ER properties due to the higher aspect ratio. The dielectric spectra also showed the relaxation time and polarizability of the PANI nanotube-based ER fluid, corresponding to its ER performance.
To promote the potential applications of ER technology, a range of substances, such as high dielectric inorganics and organics, conducting polymers, and their composites, have been developed for ER materials.4,11 Nevertheless, the application of ER fluids based on PANI is still limited by either particle sedimentation or low yield stress. To overcome these weaknesses, various efforts have been made to enhance the yield stress including the fabrication of PANI/clay nanocomposites.12
On the other hand, the shape of particles is also considered as an important factor for ER properties. For example, in the case of a PANI-based ER fluid, the morphology of the PANI micro/nanostructures strongly influences the electronic/ionic properties.13 Many studies have examined the electrorheology of nanofiber suspensions.14,15 Compared to spherical particles, fibrous-shaped particles have been reported to exhibit a larger yield stress and induced dipole moments as well as lower rates of sedimentation not only in ER fluids, but also in magneto-responsive magnetorheological fluids.16–18 Lee et al.19 and Yin et al.20 reported that PANI tubes and PANI fibers exhibited an enhanced ER effect and sedimentation ratio than granular PANI, respectively. Heat treatment of the PANI nanotubes at various temperatures was found to result in a stronger ER effect compared to the corresponding granular PANI.21 Compared to nanorods and nanospheres, titania-coated silica nanotubes22 and PANI-coated titanate nanotube4 were also showed higher yield stress and ER properties. Therefore, shaped controlling can improve the ER properties of suspensions.
Among the various ways to synthesize shape-controlled PANI, the soft template technique is one of the most effective methods because of easy processing, high yield, no organic solvents and no agitation.23–25 In this method, many reagents can be used to synthesize PANI nanotubes.19,23–27 Compared to other dicarboxylic acid dopants, the oxalic acid-doped PANI has a conducting emeraldine salt phase predominantly and high conductivity.24,28 The particle conductivity is an important factor in the ER effects.29
In this paper, PANI nanotubes were synthesized using a micelle soft-template method in the presence of oxalic acid as a dopant and adopted the dispersed phase in ER fluids. The experimental results showed that the PANI nanotube-based ER fluids exhibited improved rheological properties under various electric fields compared to the conventionally fabricated PANI-based ER fluids.19 The rheological and dielectric properties were measured, and their correlation was investigated further.
First, 2 mmol of aniline monomer and 0.5 mmol of oxalic acid were dissolved in di-water (10 ml) under sonication for 30 min. After cooled down to 4 °C, an aqueous solution of APS (2 mmol in 5 ml di-water) was added to the reactor under vigorous stirring. The resulting mixture was left to stand for 12 h at 4 °C without any disturbance. The product was washed sequentially with di-water, methanol and diethyl ether.24 The electrical conductivity of the obtained PANI was controlled by a dedoping process for its ER fluid application. Specifically, the PANI nanotubes dispersed in di-water were sonicated for 30 min, and the pH was then adjusted to 9.0 using a 1 M NaOH solution. The density of the obtained PANI nanotubes was measured to be 1.41 g cm−3, whereas the electrical conductivity was decreased from 9.5 × 10−4 to 4.7 × 10−10 S cm−1 via a dedoping process. The PANI nanotubes were shaken through a molecular sieve (100 μm) to separate the agglomerated particles. A 10 vol% ER fluid was prepared by dispersing the PANI nanotubes in silicone oil (density: 0.96 g cm−3, kinematic viscosity: 50 cS).
Fig. S1† shows the FT-IR spectrum of the PANI nanotube. The characteristic bands of the emeraldine salt of the PANI were observed; the CC stretching vibration of the quinoid and benzenoid rings at 1568 cm−1 and 1492 cm−1, respectively.30 In addition, the C–N stretching band of the secondary aromatic amine at 1303 cm−1 and the N
Q
N absorption peaks (Q: the quinoid ring) at 1135 cm−1 were observed.14 In particular, the absorption of the –COOH group at 1041 cm−1 and 509 cm−1 indicated that the resulting PANI had been doped with the carboxylic acid.23,24
Fig. S2† presents the XRD pattern of the synthesized PANI nanotubes. Peaks were observed at 2θ of 6.4°, 11.9°, 18.9°, and 25.7° and the corresponding inter-surface distances were 13.8, 7.5, 4.7, and 3.5 Å, respectively. The peaks at 18.9° and 25.7° were assigned to the periodicity perpendicular and parallel to the polymer chain, respectively.31 In particular, a sharp peak at 6.4° was attributed further to the separating aliphatic chains,32 showing the orientation of the dicarboxylic acids in the polymeric chain, which was assigned as the periodic distance between the dopant and N atom on the adjacent main chains. These results confirm that the PANI nanotubes are of partly crystalline owing to their distinctive tubular morphology and possibly the presence of the double –COOH groups of the dicarboxylic acid.23
Isothermal adsorption–desorption curve and pore size distribution of the PANI nanotubes were obtained from the N2 adsorption measurements at 77 K, as shown in Fig. S3.† The BET surface area of the PANI nanotubes was 57.8 m2 g−1. This hysteresis loop exhibited a type IV isotherm. In addition, the mean pore size was approximately 22.62 nm (inset of Fig. S3†).
Fig. 3 presents optical microscopy images of the distinctive characteristic ER phenomenon of the fibrillation process of PANI nanotubes dispersed in silicone oil under an applied electric field. Note that the ER fluids act as smart materials, whose rheological properties can be controlled precisely in an applied electric field.14,33,34 Transformations in the microstructure of the ER fluid under an applied DC electric field using a DC high voltage source were observed by the OM. The gap distance between the parallel electrodes was fixed to 150 μm. In the absence of an electric field, the particles were dispersed randomly in silicone oil like a Newtonian fluid. On the other hand, under an electric field (0.1 kV) applied, the particles began to move and form rigid fibrillated chain structures in the direction of the electric field.
The flow curves of the PANI nanotubes suspension (10 vol%, 50 cS silicone oil) under the controlled shear rate (CSR) measurement mode was examined using a rotational rheometer equipped with a high voltage generator under a range of electric field strengths, as shown in Fig. 4(a). In the absence of an electric field, the shear stress increased linearly with increasing shear rate, in which the fluid behaved similar to a Newtonian fluid.35 On the other hand, when a high electric field was applied, the ER fluid showed a large enhancement in shear stress because the particles were polarized and formed chain-like structures, as indicated in the OM images. When the strength of the electric field was enhanced, the shear stress of the PANI nanotube increased due to an inter-particle interaction force.36 As a result of the chain-like structures, the ER fluid under an applied electric field is considered a Bingham fluid with yield stress, which is described as the shear stress extrapolated to the zero shear rate limit region.
![]() | ||
Fig. 4 Flow curves of the PANI nanotubes-based ER fluid (10 vol%, 50 cS silicone oil) as a function of the shear rate with increasing electric field strengths. The line was fitted by the CCJ model. |
When the ER properties were compared with those19 of the previously studied PANI microtubes-based ER fluid, it was found that the PANI nanotube particle suspension exhibited higher shear stress than that of the PANI microtube under the same conditions, which agrees with the effect of the particle morphology on the ER properties investigated.20 Anisotropic fibrous-like particles were reported to have the strongest ER effect than that of the spherical- and granular-shaped particle suspensions, which were attributed to the viscous drag force for a fibrous particle moving perpendicular to its long axis in a fluid that was significantly larger than a spherical particle of the same volume.37 This results from the high aspect ratio, which makes particles link more strongly together and form robust chain structures.22,38 For this reason, the PANI nanotubes show higher flow resistance and shear stress, which is induced when the fluid was sheared. Therefore, the aspect ratio presents an important role in improving the ER performance.16,17 In the case of a particle suspension,39 the particle with a high aspect ratio is well-known to have a larger viscosity than that with a smaller aspect ratio based on the increased drag coefficient related to the shape. This tendency explains that the increase in the aspect ratio of the PANI nanotube enhances the flow resistance owing to its high drag coefficient.
To examine the flow curves of an ER fluid, the simple Bingham fluid model is generally adopted, introducing the dynamic yield stress (τy) and shear viscosity (η) of τ = τy + η. The dynamic yield stress can be acquired by extrapolating the flow curve to a zero shear rate limit, but in the present case, there was an unusual decreasing trend in the shear stress in the high shear rate region. Therefore, in this study, a modified rheology equation of state, the Cho–Choi–Jhon (CCJ) model,40 was used to describe the special shear stress behavior and yield stress.
![]() | (1) |
The CCJ model, as shown in eqn (1) was introduced to reanalyze the shear stress behavior by fitting the curves via six parameters. Here, τ0 is a function of the electric field, t1 and t2 are the time constants used to describe the change in shear stress, and η∞ is the shear viscosity at a high shear rate presented as the shear viscosity in the absence of an electric field. The exponent, α, is related to the reduction in shear stress at the low shear rate region, whereas β in the range of 0 to 1.0 indicates the high shear rate region. Using the optimal parameters, the CCJ model showed a much better fit to the flow curves than the Bingham model. The parameters are listed in Table 1.
Model | Parameters | Electric field strength (kV mm−1) | |||||
---|---|---|---|---|---|---|---|
0.5 | 1.0 | 1.5 | 2.0 | 2.5 | 2.7 | ||
CCJ | τ0 | 39.95 | 113 | 207.59 | 319.61 | 446.67 | 452 |
t1 | 0.0001 | 0.004 | 0.002 | 0.0015 | 0.003 | 0.005 | |
α | 0.3 | 0.45 | 0.38 | 0.3 | 0.3 | 0.4 | |
η∞ | 0.266 | 0.315 | 0.391 | 0.482 | 0.581 | 0.625 | |
t2 | 0.3 | 0.05 | 1 | 0.08 | 0.5 | 0.02 | |
β | 0.8 | 0.7 | 0.9 | 0.9 | 0.8 | 0.9 |
Fig. 4(b) shows the shear viscosity as a function of the shear rate. Compared to the consistent viscosity at a zero electric field exhibiting Newtonian fluid characteristics, general shear thinning behavior was obtained under different electric field strengths.41 The shear thinning behavior becomes increasingly significant with increasing shear rate and electric field strength.
From the measured flow curves, the dynamic yield stresses (τy) were presented by extrapolating the shear stress at a 0.1 s−1 shear rate from Fig. 4(a). In general, the interrelationship between the dynamic yield stress and electric field strength (E) can be represented by a power-law relationship as follows:
τy ∝ Eα | (2) |
The power law index α was suggested to be 1.5 in the conduction model, and α = 2 was indicated by the polarization model.42 The power law dependence α was found to approach 1.5 for these ER fluids (Fig. 5).
![]() | ||
Fig. 5 Yield stresses versus electric field strength for PANI nanotubes-based ER fluid (10 vol%, 50 cS silicone oil). The line is fitted by eqn (2). |
To examine the sensitivity and stability of the PANI nanotubes-based ER fluid, the shear stress was measured at a fixed shear rate of 1 s−1 using a square voltage pulse (t = 20 s), as shown in Fig. 6. Under each applied electric field, the shear stress increased upon the application of the external electric field and decreased immediately to a zero-field level when the electric field was removed. The transition of the shear stress at each turning point was fast and the shear stress was quite steady at the same electric field, indicating sensitive, reversible well-controlled ER characteristics. These are optimistic results for the applications of PANI nanotube-based ER materials in controlled mechanical systems.8–10,43
![]() | ||
Fig. 6 Shear stress of the PANI nanotubes-based ER fluid (10 vol%, 50 cS silicone oil) in the electric field with a square voltage pulse (t = 20 s) at a fixed shear rate of 1 s−1. |
A dynamic oscillation measurement was conducted to analyze the viscoelastic properties of the ER fluid. Before the test, the strain amplitude sweep tests were performed to find a linear viscoelastic region (γLVE) at a certain angular frequency of 6.28 rad s−1 (1.0 Hz), as shown in Fig. 7(a). This specific angular frequency was recommended by the manufacturer and several previous experiments in ER systems were also performed at this frequency.16,44,45 At the low strain region, the storage modulus, G′, is always higher than that of the loss modulus G′′. In addition, the values of G′ and G′′ are independent within the region of strain, which referred to as the linear viscoelastic region.46 In the γLVE, the elasticity is superior (G′ > G′′) compared to the viscosity, and the structures generated from the electric fields are the same. When the applied strain exceeds γLVE, both G′ and G′′ are reduced significantly due to the irreversible transition in the structure of the ER fluid. In addition, the value of G′′ becomes larger than that of G′. This suggests that the structures begin to break down after a certain degree of deformation with the increased input strain. The elasticity of the ER fluid disappeared rapidly at a certain degree of strain.
Under the induced electric fields, the ER fluid showed a transition from a viscoelastic liquid to a viscoelastic solid.46 This transition causes the formation of particle aggregates, string and then rigid column structures. In the strain amplitude sweep test, slight deformation results in an unstable state, as shown in Fig. 7(a). The data was reanalyzed to the magnitude of elastic component of stress (τ′ = G′γ) as a function of strain, which is an effective way of examining the progressive structural breakdown,47 (Fig. 7(b)). The rigidity of the fluid begins to deteriorate at the critical strain (γc), which shows the linearity limit of the dynamic modulus.45 γc increased linearly with increasing electric field from 0.08 to 0.2%, as shown in the Fig. 7(b) inset. This yield strain point reflects the breaking of the interparticle bonds in the fluid network. This energy dissipation explains the decrease in G′ and G′′ (Fig. 7(a)), as well as the sublinear strain–stress relationship in Fig. 7(b). With increasing electric field strength, the attraction force between the neighboring ER particles was enhanced, which tends to suppress bond breakage affecting the increase in γc. The elastic component of the stress increased linearly with strain within the linear viscoelastic limit, reaching equilibrium, after which yield or structural breakdown occurred. The maxima or shoulders of these points provide another way of examining the yield points.45,47 The elastic yield stresses (τe) also increased with increasing applied electric field strength and showed a power-law dependence with an exponent of 1.5, as shown in Fig. 5. It is interesting to compare this result of τe from dynamic oscillation test with the τy, in which the dynamic yield stress τy is obtained from the controlled shear rate measurement via an extrapolation method at a very low shear rate. On the other hand, it was further observed that the yield stress measured from the steady-state measurement is slightly larger than the one determined by dynamic investigation.48 Nonetheless, both of the yield stresses as a function of electric field strength showed similar tendency.
Previously selected γLVE value was applied to the frequency sweep measurements. Both G′ and G′′ were measured over the angular range, 1 to 100 rad s−1, with a strain of 0.01% in γLVE, as shown in Fig. 8(a). The G′ and G′′ values increased with increasing electric field strength. G′ was always higher than G′′, suggesting the dominance of the elastic behavior beyond the viscous behavior in the structure of the ER fluid. G′ was almost stable when the deformation frequency was increased to 100 Hz, which is similar to the typical behavior of combined colloidal dispersions and cross-linked rubber.49 Moreover, the relaxation time for deformation was long enough and it is believed that the ER fluid with the interfacial polarized chain structures was not destroyed by deformation under the allowed condition. This increase in G′ under an applied electric field indicates the enhanced solidification properties of the PANI nanotubes suspension.
This solid-like behavior can be explained by the damping factor, tanδ, which is defined as the ratio of the loss modulus (viscous) to the storage modulus (elastic) as follows:50
tan![]() | (3) |
Fig. 8(b) shows the tanδ value of the PANI nanotube as a function of angular frequency. tan
δ was less than 1 over the entire frequency range representing solid-like properties of the PANI nanotube due to highly concentrated particulates. An increased electric field resulted in a decrease in tan
δ, indicating that the strong particle interaction in the PANI nanotube and the elastic properties of PANI nanotube suspension were further enhanced compared to the lower electric field.
This change in PANI nanotubes to a solid-like state can also be confirmed by examining the stress relaxation behavior. Observing the relaxation behavior is one way of confirming the phase change in an ER fluid from a liquid-like to solid-like phase. Instead of performing the stress relaxation measurement directly, they can be estimated from the dynamic modulus data. Fig. 9 shows the stress relaxation behavior, in which the stress relaxation modulus G(t) was calculated from the values of G′(ω) and G′′(ω) in Fig. 8(a) using the Schwarzl equation, which is the numerical formula given as follows:51,52
G(t) ≅ G′(ω) − 0.560G′′(ω/2) + 0.200G′′(ω) | (4) |
![]() | ||
Fig. 9 Relaxation modulus G(t) of the PANI nanotube-based ER fluid (10 vol%, 50 cS silicone oil) as calculated from G′(ω) and G′′(ω). |
The very short-term behavior of the material, which is difficult to obtain experimentally because of the intrinsic properties of polymeric materials and the limitation of the mechanical measurement arising from the equipment itself, can be predicted from this equation. G(t) becomes linear with increasing electric field on a log–log scale, indicating that all are solid-like except in the absence of an electric field.
The dielectric properties were examined to verify the ER performance of the PANI nanotube suspension. Fig. 10 shows the dielectric spectra as a function of the frequency, and Cole–Cole fitting plot for the PANI nanotubes-based ER fluid analyzed by the Cole–Cole equation:53
![]() | (5) |
![]() | ||
Fig. 10 (a) Dielectric constant and loss factor as a function of the frequency and (b) Cole–Cole plot of PANI nanotube-based ER fluid (10 vol%, 50 cS silicone oil). The lines were fitted from eqn (5). |
Footnote |
† Electronic supplementary information (ESI) available. See DOI: 10.1039/c4ra13635g |
This journal is © The Royal Society of Chemistry 2015 |