Yu Huab,
Jing Jin*a,
Yuanyuan Hana,
Jinghua Yina,
Wei Jiang*a and
Haojun Liangc
aState Key Laboratory of Polymer Physics and Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022, PR China. E-mail: wjiang@ciac.ac.cn; jjin@ciac.ac.cn; Fax: +86-431-85262126; Tel: +86-431-85262151
bGraduate University of Chinese Academy of Sciences, Beijing 100049, PR China
cCAS Key Laboratory of Soft Matter Chemistry, Department of Polymer Science and Engineering, University of Science and Technology of China, Hefei, Anhui 230026, PR China
First published on 8th January 2014
Protein adsorption behavior is a key factor that determines whether materials can be used as medical polymer materials. In this study, fibrinogen (Fib) adsorptions on three different poly(ethylene glycol) (PEG) surfaces that differed in chain length and chain density were investigated using a quartz crystal microbalance with dissipation (QCM-D) and a dual polarization interferometry (DPI) with respect to adsorbed masses, viscoelastic properties and chain conformations. On QCM-D chips, PEG chains were tight and in extended brush conformations. Meanwhile, on DPI chips, PEG1000 and PEG2000 may have the same pancake-like conformations, but PEG5000 had a mushroom conformation. Moreover, several bare spaces were observed on the loose pancake-like PEG1000- and PEG2000-modified DPI surfaces. Fib could fully spread on the relatively dense PEG1000-modified DPI surface and partly spread and tightly orient on the relatively sparse PEG2000-modified DPI surface. Thus, grafting density was found to have greater significance in determining Fib adsorption resistance due to its influence on Fib spreading when the chain conformations of hydrophilic molecules were loose pancake-like structures. Furthermore, brush and mushroom structured PEG5000 chains both had high deformation capacity, which excellently resisted protein adsorption by adjusting their conformation to decrease interaction with Fib. Therefore, the Fib adsorption resistance of PEG-modified surface depended on the grafting density of PEG layer and the deformation capacity of the PEG chain.
Fib adsorptions on various substrates have been extensively studied.5 The adsorption on polymer surface is a complex process. It involves van der Waals forces, hydrophobic interactions, electrostatic interactions, and hydrogen bonding6,7 and depends on the chemical and physical characteristics of the surface, such as hydrophilicity, densities, conformations, and orientations of surface polymer chains.8 Zbigniew Adamczyk et al. performed systematic studies on Fib adsorption on polystyrene (PS) latex particles. They proposed a robust procedure of preparing Fib monolayer on the PS surface of well-controlled orientation and coverage for immunological assays9 and presented two main adsorption mechanisms of Fib, namely, the random and the side-on adsorption mechanisms.10 However, a few working about mechanism of Fib adsorption on the hydrophilic polymer surface, such as poly (ethylene glycol) (PEG)-modified surface, has been conducted.11 PEG is a nontoxic and nonimmunogenic polymer that possesses excellent protein resistant property.12 Moreover, PEG is also commonly used to induce protein crystallization.13 PEG layer density, chain length and chain conformation14 are important factors affecting the protein resistant of the PEG layer.15,16 Although the interactions between Fib and PEG-modified surface have been studied for many years,17–19 the dynamic interaction mechanism in the molecular level of resistance of PEG against Fib adsorption is yet to be clarified.
Currently, some new techniques, such as ellipsometry,20 total internal reflection fluorescence,21 quartz crystal microbalance with dissipation (QCM-D),22,23 and surface plasmon resonance24 are used to probe the interaction between protein and polymer surface. However, the protein needs to be labeled in some of these techniques, and the information obtained by using these techniques individually is limited. As a result, the dynamic interaction between protein and surface can hardly be elucidated in the molecular level. Additionally, only a few studies have investigated the quantitative structure–property relationships between protein and surface from the perspective of protein denaturing and orientation changes.25 Therefore, a combination of QCM-D and other techniques, such as dual polarization interferometry (DPI), ellipsometry,26 neutron reflectivity, and high-energy X-ray reflectivity27 is imperative for the investigation of protein adsorption on polymer surface. Based on the inverse piezoelectric effect of piezoelectric quartz crystal, QCM-D is a powerful tool for examining the tiny mass variation on crystal surface and the viscoelasticity property of the adsorbed layer simultaneously in real-time.28 Meanwhile, DPI is a surface sensitive technique for the real-time monitoring of the interaction in the solid–liquid interface, which can simultaneously obtain the changes in layer mass, thickness, and density.29 Several groups have studied the interaction between biomacromolecules and interface and surface properties using these two techniques.26,30–32 Kairuo Xu et al.33 investigated lysozyme adsorption on a silica surface by combining these two techniques in parallel and proposed a tentative lysozyme adsorption model.
In the present study, both QCM-D and DPI were performed in a parallel manner to investigate the process of thiolated (SH–) monomethoxy PEG (mPEG) immobilization as well as the interaction between PEG modified surfaces and Fib. PEG-modified surfaces were fabricated with different molecular weights. The SH-mPEG chains and Fib adsorption processes on the different modified surfaces were monitored with QCM-D and DPI. The dynamic variation of the adsorbed layer properties were recorded in real-time. This study aims to provide a new understanding of the Fib adsorption on the PEG layer from another perspective and elucidate the key factors to obtain an effective protein-resistant PEG-modified surface.
:
1
:
1 (v/v) solution of deionized water, ammonia (25%) and hydrogen peroxide (30%) for 5 min at 75 °C. After excessive rinsing with deionized water, the chip was blown dried with high purity nitrogen.34 Before our experiment, the instrument channel was cleaned using Hellmanex™II diluted solution (2%, in deionized water, v/v) at a flow rate of 30 μL min−1 for 10 h and followed by deionized water at a flow rate of 500 μL min−1 for 2 h to eliminate any contaminant of the instrument. In QCM-D experiment, the temperature was controlled at 20 °C (±0.02 °C) and the flow rate was fixed at 100 μL min−1. The concentration of mPEG-SH in PBS buffer was fixed at 0.2 mM, and the concentration of Fib solution was 0.01, 0.1, and 1 mg mL−1, respectively. Notably, in every solution changing procedure, the pump was stopped to prevent any air injecting in.
The change of adsorbed mass produced shifts of the frequency and the viscoelasticity variation of the adsorbed layer could induce the dissipation variation. The principle of QCM-D is based on the inverse piezoelectric effect of piezoelectric quartz crystal. When the crystal was exposed to a sinusoidal electric field, a shear oscillation could be induced at the resonance frequency and the crystal's oscillation frequency decreased if an increase in mass bound to the quartz surface.35–37 For a flat, uniform, and rigid adsorbed layer, frequency shift is proportional to the change in the adsorbed mass, and Sauerbrey relation can be used to calculate the adsorbed mass.38
| ΔM = −CΔf/n | (1) |
| Δf = f1(n,ηf,ρf,μf,σf) | (2) |
| ΔD = f2(n,ηf,ρf,μf,σf) | (3) |
| G* = G′ + jG′′ = μ + j2πfη | (4) |
In our fitting process, overtones n = 3, 5, 7, 9, 11, 13 were used, allowing the model to fit the data and calculate the four unknown parameters (η,ρ,μ,σ) by iterating using QTools software (Q-Sense). Adsorbed layer density was assumed as 1200 kg m−3 (consider the layer density value between the banding water density 1000 kg m−3 and protein density 1400 kg m−3).43 The density and viscosity of the liquid phase were set as 1000 kg m−3 and 0.001 kg ms−1, respectively. The density of the each layer was iterated to find a suitable value then fixed in. The parameters of the layer viscosity, layer shear modulus and layer thickness were set in the range of 0.0001–0.1 kg ms−1, 1 × 105 to 1 × 107 Pa, 1 × 10−11 to 1 × 10−6 m, respectively.44
:
3) for 30 min at 80 °C. Afterward, the chip was rinsed with ultrapure water and blown dry with high purity nitrogen. The amino chip was obtained by silanizing the silica chip. The cleaned silica chip was immersed in the 4% (v/v) (3-aminopropyl) triethoxysilane/isopropanol solution for 2 h at room temperature, and then rinsed with isopropanol excessively. After being blown dried with high purity nitrogen, the chip was baked in oven at 120 °C for 30 min. After this, amino-modified chip was obtained.45
Amino-modified chip was loaded into the instrument and each chip had two fluidic channels, channel 1 and channel 3, allowing two parallel experiments simultaneously. Temperature of the instrument was stabilized at 20 °C (±0.002 °C). Degassed PBS buffer was injected first at a flow rate of 50 μL min−1 until a stable base line was gained. Then degassed 80 wt% ethanol in water mixture was injected, followed by degassed ultrapure (UHQ) water for 10 min each at a flow rate of 50 μL min−1 for calibration. After this, degassed PBS buffer was injected at the same flow rate. After the base line stable again, protein adsorption experiment started to conduct. The volume of each solution injection in the following experiments was fixed at 150 μL. Firstly, degassed sulfo-GMBS/PBS solution (1 mg mL−1) was injected at a flow rate of 15 μL min−1 for 10 min to activate the amino-modified chip, and then rinsed by PBS buffer (degassed) for 10 min. Next, a certain concentration of SH-mPEG in PBS buffer was injected at a rate of 15 μL min−1 for 10 min, and then rinsed by PBS to remove the physical adsorbed PEG. Different molecular weights PEG surfaces could be modified on DPI chips using the above method. Lastly, Fib in PBS buffer with three different concentrations (0.01, 0.1, and 1 mg mL−1) was injected at 10 μL min−1 for 15 min. The loose bound Fib was removed by PBS rinsing. After experiment, instrument was cleaned by 4% (w/v) Hellmanex solution (Hellma GmbH & Co.,) for at least 2 h at a flow rate of 50 μL min−1, then rinsed by 50% (w/v) isopropanol aqueous solution at 50 μL min−1 for at least 2 h. At last, changed the rate to 25 μL min−1 and cleaned the instrument overnight.
In DPI procedure, the transverse electric (TE) and transverse magnetic (TM) signals were recorded in real-time. Layer thickness and refractive index (RI) could be achieved through the analysis of AnaLight® software (AnaLight® Resolver software, version 2.1.4). Then, the adsorbed mass was obtained according to the De Feijter equation46 as follows:
![]() | (5) |
| mL = ρL·τL | (6) |
Table 1 presents the PEG grafting situations detected by QCM-D and DPI. The thickness of PEG on the QCM-D chips increases monotonously with PEG molecular weight, whereas its thickness on DPI chip is more complex. The thicknesses of PEG1000 and PEG2000 on DPI chips have nearly the same values, that is, 0.47 ± 0.09 nm and 0.42 ± 0.06 nm, respectively. However, the thickness of PEG5000 on DPI chips can reach up to 1.01 ± 0.21 nm. This result can be attributed to the difference of PEG chain conformations. The conformation of the grafted PEG chains is critical for the subsequent Fib adsorption on the modified surface. The theory work by Alexander47 indicated that the conformation of end-tethered chains on the surface in solution depended on the grafting density Γ. However, the graft spacing S could more accurately reflect the conformations of PEG chains on QCM-D and DPI chips. The graft spacing S represents the distance between two PEG-chain attachment points, which can be derived using the following formula.
| S = Γ(−1/2) | (7) |
| PEG | ΔF (Hz) | ΔD(× 10−6) | Thickness (nm) | Γa (chains nm−2) | S = Γb(−1/2) (nm) | 2RFc (nm) | |
|---|---|---|---|---|---|---|---|
| a Γ is chain density.b S is the distance between two PEG chains attachment points.c RF is Flory radius, RF = aNν, a is the ethylene oxide repeat characteristic monomer dimension and taken as 0.278 nm, N is the degree of polymerization, ν taken as 0.6 for high-solubility conditions.48 | |||||||
| QCM-D | Mw 1000 | 17.2 ± 3.3 | 0.87 ± 0.12 | 2.5 ± 0.4 | 1.81 ± 0.3 | 0.74 | 3.55 |
| Mw 2000 | 26.3 ± 1.5 | 0.97 ± 0.11 | 4.0 ± 0.2 | 1.51 ± 0.1 | 0.81 | 5.46 | |
| Mw 5000 | 45.1 ± 1.8 | 1.53 ± 0.14 | 6.8 ± 0.3 | 0.99 ± 0.1 | 1.01 | 9.48 | |
| DPI | Mw 1000 | — | — | 0.47 ± 0.09 | 0.10 ± 0.01 | 3.16 | 3.55 |
| Mw 2000 | — | — | 0.42 ± 0.06 | 0.05 ± 0.01 | 4.47 | 5.46 | |
| Mw 5000 | — | — | 1.01 ± 0.21 | 0.03 ± 0.01 | 5.77 | 9.48 | |
Meanwhile, the hydrodynamic radius of PEG coil in solution can be reflected by Flory radius RF as follows:
| RF = aNv | (8) |
Table 1 shows that the S values of PEG-modified QCM-D chips with three molecular weights are actually considerably smaller than their corresponding 2RF values, indicating that the PEG chains on QCM-D chips are all tight and in extended brush conformations. In addition, the S values on QCM-D surfaces are smaller because the mass is the hydrated mass that contains coupled water. Fig. 3 is a schematic diagram demonstrating the chain conformation of PEG on QCM-D and DPI chips. Moreover, the PEG1000 layer has the largest grafting density, and the PEG2000 and PEG5000 layers have lower grafting densities on QCM-D chips. Although the S values of PEG-modified DPI chips with three molecular weights are also smaller than their corresponding 2RF values, the difference between S and the corresponding 2RF is relatively insignificant. Compared with the PEG-modified QCM-D chip, the chain density Γ of the PEG-modified DPI chip is relatively low. Thus, the conformations of PEG chains on DPI chips are relatively sparse and loose (Fig. 3). Furthermore, the thickness difference on the PEG-modified DPI chips indicates that PEG1000 and PEG2000 may have the same pancake-like conformations, whereas PEG5000 has a mushroom conformation.
![]() | ||
| Fig. 4 Adsorbed mass of Fib at different concentrations on PEG surfaces with different molecular weights detected by (A) QCM-D and (B) DPI. | ||
![]() | ||
| Fig. 5 Real-time DPI measurement of thickness, mass, and density during the grafting of (A) PEG1000 and (B) PEG5000. | ||
![]() | ||
| Fig. 6 Cartoon diagram of Fib adsorption on PEG5000 modified surface and PEG1000 modified surface in DPI procedure. | ||
Contrastingly, the PEG5000 layer thickness gradually increases to 1.8 nm over time. After rinsing with PBS, the PEG5000 layer thickness reaches up to 1.2 nm (Fig. 5B). The grafting process of PEG5000 onto the DPI chip is totally different from that of PEG1000. The thiol terminal group of PEG5000 is difficult to be exposed because of the long chain entanglement and steric hindrance, leading to the time dependence of the grafting mass and thickness. As the mass of PEG5000 increases, the local segment–segment repulsion of PEG5000 accumulates and the grafting considerably slows down. As the result of the balance between the local segment–segment repulsion and elasticity of the PEG5000 chains, the segments that adsorbed on the chip begin to desorb and protrude from the surface, forming additional loops and tails.50 Finally, the conformation of PEG5000 on the DPI surface can form a mushroom structure.
The above analysis implies that the PEG1000 chains show a pancake-like conformation, whereas the PEG5000 chains exhibit a mushroom conformation on the DPI chips. Furthermore, PEG5000 has excellent Fib adsorption resistance on the DPI and QCM-D chips. We can now provide a detailed explanation by comparing the Fib adsorption process on PEG5000 and PEG1000 modified surfaces. Table 1 shows that the dissipation shift of PEG5000 is nearly twice as that of PEG1000, suggesting that the PEG5000 layer has better viscoelasticity property compared to the PEG1000 layer. The dissipation shifts with time during the grafting of PEG1000 and PEG5000 on the QCM-D chips are shown in Fig. 7. Once the PEG5000 solution is injected into the QCM-D chamber, the dissipation shift rapidly increases to 3 × 10−6. After PBS rinsing, the dissipation shift drops to 1.53 × 10−6. However, no obvious dissipation shift is found on the PEG1000-modified QCM-D chip after PBS rinsing. The larger dissipation shift on the PEG5000-modified QCM-D chip can be attributed to the flexibility of longer PEG chain and larger viscoelasticity. When Fib is injected into the surface, the dissipation change of the PEG1000 surface becomes larger than that of PEG5000. This result is because the PEG5000 layer possesses high deformation capacity, which can effectually reduce the interaction between the PEG chains and the Fib molecules by adjusting its conformation. Ishihara et al.51 also suggested that polymer brush layers, which possessed higher elastic repulsion energies, could extremely suppress the protein–surface interactions. In other words, if a Fib molecule attempts to compress the PEG5000 molecule chain, a greater loss in the conformation entropy of the PEG5000 chain ensues because of the high deformation capacity of the PEG5000 chain. This entropy loss can generate a larger repulsive force between the Fib molecule and the PEG5000 chain. Thus, the PEG5000 chain with brush and mushroom structures on the QCM-D and DPI chips, respectively, both have high deformation capacity, which can resist protein adsorption excellently by adjusting its conformation to decrease the interaction with Fib.
Fib is an adhesive protein with a rod-like structure and has 47 nm × 5 nm × 5 nm dimensions. The theoretical adsorption amounts of Fib on a surface in the side-on and end-on close-packed monolayer surface coverage are 2.4 ng mm−2 and 22.6 ng mm−2, respectively.7 Fig. 4 reveals that all of the Fib adsorbed masses on the DPI surfaces are lower than 1.0 ng mm−2. The adsorbed Fib on PEG-modified surfaces forms a monolayer. At this low-Fib surface coverage on hydrophilic surfaces, Fib is adsorbed in an elongated, less compacted manner.52 This explanation is based on the assumption that no conformational changes occur the hydrophilic surfaces.53 By varying PEG grafting density and Fib concentration, the Fib molecules adsorb with a different degree of spreading because of the different spaces available. Fig. 8 shows the information on the Fib adsorption on the PEG1000- and PEG2000-modified DPI surfaces at the concentrations of 0.1 and 1 mg mL−1. At low Fib concentration (0.1 mg mL−1), the thickness of Fib on the PEG1000-modified surface rapidly increases to 0.8 nm, whereas that on thePEG2000-modified surface increases gradually, decreases slightly after a peak 6 nm, and finally tends to be stable. By combining the dimensions of Fib and the value of the thickness variation, the orientation of adsorbed Fib can be inferred. The adsorbed Fib on the PEG1000-modified surface is more likely to be in a fully spread because of the weak electrostatic interaction. This binding through positive substance and negative Fib domains can lead to a less tight binding and a higher energy loss, as shown in the dissipation in Fig. 7. Thus, the space available for the coming Fib is insufficient. However, on the PEG2000-modified surface, the thickness of a monolayer Fib is 4.8 nm, which is approximate to the minor axis of Fib. Thus, the adsorbed Fib on the PEG2000-modified surface may be in a side-on orientation in z-axis and an elongation in x-axis. Therefore, Fib can fully spread on the relatively dense PEG1000-modified DPI surface and partly spread and tightly orient on the relatively sparse PEG2000-modified DPI surface. As the Fib concentration increases to 1 mg mL−1, the surface is jam-packed with Fib, and the Fib thickness on the PEG1000 and PEG2000 surfaces are 2.0 and 3.0 nm, respectively. The degree of Fib spreading decreases whereas the adsorbed amounts largely increase. Thus, due to the high Fib concentration and low surface coverage, the difference of Fib adsorbed mass between PEG1000 and PEG2000 because of the grafting density influence can be weakened.
We also compare changes of Fib adsorption rate on the PEG1000- and PEG2000-modified surfaces (Fig. 9) at the concentration of 0.1 mg mL−1. The adsorption rate on the QCM-D chip is taken as a derivative of the frequency with respect to time, and the rate on the DPI chip is taken as a mass derivative with respect to time. The Fib adsorption rates on the PEG1000- and PEG2000-modified QCM-D chips have nearly the same tendency. Actually, in the early stages of adsorption (i.e., 10 min), the Fib adsorption rate on the PEG2000 surface is slightly faster than that of the PEG1000 surface at the same time. This result can be due to the high PEG grafting density of PEG1000 (1.81 chains nm−2) compared with that of the PEG2000 on QCM-D chips (1.51 chains nm−2). Nevertheless, a significant difference is found in the Fib adsorption rate on the PEG1000- and PEG2000-modified DPI chips. The Fib adsorption rate on PEG2000-modified DPI chip is faster than that of on the PEG1000-modified DPI chip. The adsorption rate of Fib on the PEG2000-modified DPI chip quickly decreases from 0.2 ng mm−2 min−1 to zero within 4 min, whereas the rate on the PEG1000 modified surface changes smoothly over time. The fully spreading and elongation of Fib on the PEG1000 surface resists the increasing of Fib. Moreover, Table 1 shows that the conformations of PEG1000 and PEG2000 on the DPI chips have pancake-like structures, and their grafting densities are 0.10 and 0.05 chains nm−2, respectively. Their thicknesses on these surfaces are both approximately 0.5 nm. In these sparse PEG-modified surfaces, the grafting density of the PEG1000-modified surface is twice that of the PEG2000-modified surface. This lower surface coverage for the PEG2000-modified surface results in a stronger interaction with Fib compared to the PEG1000-modified surface. Additional Fibs can be easily adsorbed on the PEG2000 surface. Furthermore, the footprint of Fib on PEG2000 is smaller than that on PEG1000. We can conclude that the grafting density has a greater significance in determining the Fib adsorption resistance when the chain conformations of hydrophilic molecules have loose pancake-like structures. Fib could fully spread on the relatively dense PEG1000 layer and partly spread and tightly orient on the relatively sparse PEG2000 layer.
![]() | ||
| Fig. 9 Fib (0.1 mg mL−1) adsorption rate on PEG1000 and PEG2000 surface detected by QCM-D (A) and DPI (B). | ||
Fib adsorptions on PEG-modified surfaces were investigated by QCM-D and DPI with respect to adsorbed masses, viscoelastic properties and chain conformations. Several bare spaces were observed on the loose pancake-like PEG1000- and PEG2000-modified DPI surfaces. The adsorbed Fib on the PEG1000-modified surface was more likely to be in a more elongated and fully spread because of the weak electrostatic interaction. However, the adsorbed Fib on the PEG2000-modified surface may be in a side-on orientation in z-axis and an elongation in x-axis. The Fib adsorption rate on PEG2000-modified DPI chip was faster than that of on the PEG1000-modified DPI chip. Fib could fully spread on the relatively dense PEG1000-modified DPI surface (0.10chains nm−2) and partly spread and tightly orient on the relatively sparse PEG2000-modified DPI surface (0.05chains nm−2). Thus, grafting density was found to have greater significance in determining Fib adsorption resistance due to its influence on Fib spreading degree when the chain conformations of hydrophilic molecules were loose pancake-like structures. Furthermore, the PEG5000 layer possessed excellent Fib resistance, regardless of whether the PEG5000 chains were in brush or mushroom conformations and whether the flow rate was high or low. Both brush and mushroom structured PEG5000 chains had high deformation capacity, which can effectively resisted protein adsorption by adjusting their conformation to decrease interaction with Fib. Therefore, the Fib adsorption resistance of PEG-modified surface depended on the grafting density of PEG layer and the deformation capacity of the PEG chain.
| This journal is © The Royal Society of Chemistry 2014 |