Manganese displacement from Zinpyr-1 allows zinc detection by fluorescence microscopy and magnetic resonance imaging

Youngmin You ab, Elisa Tomat a, Kevin Hwang a, Tatjana Atanasijevic c, Wonwoo Nam b, Alan P. Jasanoff c and Stephen J. Lippard *a
aDepartment of Chemistry, Massachusetts Institute of Technology, Ca, m, bridge, Massachusetts 02139, USA. E-mail: lippard@mit.edu; Fax: +1-617-253-1892; Tel: +1-617-258-8150
bDepartment of Chemistry and Nano Science and Department of Bioinspired Science, Ewha Womans University, Seoul 120–750, Korea
cDepartment of Biological Engineering, Massachusetts Institute of Technology, Ca, m, bridge, Massachusetts 02139, USA

Received 1st March 2010 , Accepted 8th April 2010

First published on 10th May 2010


Abstract

A paramagnetic manganese complex of a fluorescein-based probe affords a dual-modality zinc sensor featuring an improved fluorescence dynamic range and an MRI readout.


Several metal-based receptors have been employed in displacement assays1 to detect biologically relevant analytes, such as carbonate,2 phosphate,3 and nitric oxide.4 In optical sensors that provide a fluorescence readout, the emissive reporter is typically quenched by coordination of a paramagnetic metal ion, which is displaced by the analyte to provide an increase in emission intensity. Alternatively, fluorescent detection systems can exploit differences in binding affinities of two coordinating cations and in the optical properties of their corresponding complexes. For instance, transmetalation reactions involving Zn(II) and Cd(II) convey ratiometric sensing of these ions in neutral aqueous solutions.5,6 In addition, Hg(II) ions liberate Cu(II) from a fluorescent receptor to give emission turn-on in DMSO/water solution.7 Recently, we demonstrated that displacement of Mn(II) from polydentate chelating agents allows Ca(II) detection by magnetic resonance imaging (MRI) in vitro.8 In the present communication, we recapitulate the design of displacement probes in a dual-modality Mn(II)-based system that allows zinc detection by both fluorescence and MRI readouts.

The development of fluorescent sensors featuring a wide dynamic range (Φmetal/Φfree) is one of the current challenges in the field of biological zinc detection.9,10 We reasoned that background fluorescence derived from fluorophores in the zinc-free state, including proton-induced fluorescence, could be avoided by pre-complexation of the sensor with a paramagnetic ion, which can quench sensor fluorescence by acting as the acceptor in a nonradiative energy- or electron-transfer process. Displacement of the paramagnetic center by zinc coordination would then afford a highly emissive zinc complex and hence a turn-on signal. For intracellular imaging, use of Mn(II) as the paramagnetic center is preferable when compared to other ions employed in displacement assays, such as toxic Cd(II)6 and tightly regulated Cu(II).7 A Mn(II) displacement approach is employed herein to improve the fluorescence dynamic range of Zinpyr-1 (ZP1, Scheme 1), a zinc-responsive fluorescent indicator that has found wide applicability for the detection of biological mobile zinc.11,12


Complex [ZP1Mn2] and displacement reaction.
Scheme 1 Complex [ZP1Mn2] and displacement reaction.

The fluorescence intensity of ZP1 decreases (Φfree = 0.17 → ΦMn = 0.0067) promptly upon addition of MnCl2, leveling off after 2 equiv. The stoichiometry for the ZP1−Mn2+ complex ([ZP1Mn2]) is 1 ∶ 2 as revealed by a fluorescence Job's plot and a mole ratio plot (ESI). Apparent dissociation constant values for the [ZP1Mn2] complex were obtained by non-linear least-squares fitting of fluorescence titration data to give 0.55 μM and 2.2 μM for the first and second binding events, respectively. These Kd values are ca. 1010 and 103 times greater than those for Zn(II) in [ZP1Zn2],13 indicating that manganese displacement by zinc ions is thermodynamically highly favored. As expected, addition of ZnCl2 to a [ZP1Mn2] solution immediately enhanced fluorescence emission (Fig. 1) due to formation of [ZP1Zn2] (ΦZn = 0.71). The Zn(II)-induced fluorescence response for the displacement reaction was as fast as that of simple Zn(II) association in the time scale of our steady-state measurements (i.e., typically 1 titrant addition per minute). The corresponding fluorescence dynamic range increases by 25-fold, from 4 for ZP1 to 106 for [ZP1Mn2]. This improved fluorescence turn-on persists even in the presence of a large excess of Mn2+ (up to 1000 equiv., ESI). Although the fluorescence dynamic range decreases at pH 6.0 and 8.0, it remains at a relatively high level (31 and 36, respectively) (Fig. 1). In addition, [ZP1Mn2] selects Zn2+ over biologically abundant metal ions such as Na+, K+, Ca2+ and Mg2+. Hg2+ and Cd2+ ions displace Mn2+ to enhance fluorescence, which further increases after addition of Zn2+. In contrast, as expected from the Irving−Williams series, Zn2+-induced fluorescence turn-on does not occur in the presence of the tightly binding paramagnetic Cu2+, Co2+ and Fe2+ ions.


Zinc-induced (0 to 3 equiv.) fluorescence enhancement of (a) ZP1 and (b) [ZP1Mn2] at pH 7.0 (10 μM). (c) Fluorescence dynamic range (ΦZn/Φfree) of ZP1 (black) and [ZP1Mn2] (red) at pH 6.0 (50 mM MES, 100 mM KCl), 7.0 (50 mM PIPES, 100 mM KCl) and 8.0 (25 mM HEPES, 100 mM KCl).
Fig. 1 Zinc-induced (0 to 3 equiv.) fluorescence enhancement of (a) ZP1 and (b) [ZP1Mn2] at pH 7.0 (10 μM). (c) Fluorescence dynamic range (ΦZn/Φfree) of ZP1 (black) and [ZP1Mn2] (red) at pH 6.0 (50 mM MES, 100 mM KCl), 7.0 (50 mM PIPES, 100 mM KCl) and 8.0 (25 mM HEPES, 100 mM KCl).

The [ZP1Mn2] probe was employed to detect exogenous zinc in live cell imaging experiments. HeLa cells were incubated with [ZP1Mn2] (10 μM), which proved to be cell-permeable and non-toxic. For direct comparison, cells were similarly treated with unmetallated ZP1. As shown in Fig. 2, almost no background signal is observed for [ZP1Mn2]-treated HeLa cells, whereas broad fluorescent halos appear in ZP1-treated cells. Exogenously supplied Zn2+ (ZnCl2/sodium pyrithione, 1 ∶ 1, 50 μM) causes the appearance of bright signals. Although the physiological effects of liberated Mn2+ ions were not investigated in detail, the overall morphology of cells appeared intact after displacement. Compared to ZP1, [ZP1Mn2] affords superior fluorescence contrast, a definite benefit of the reduced background emission. Additional incubation with N,N,N′,N′-tetra(2-picolyl)ethylenediamine (TPEN, 50 μM) reduced the fluorescence signal, as expected for a zinc-responsive turn-on probe (ESI).


Fluorescence microscopy images of HeLa cells incubated with ZP1 or [ZP1Mn2]. Left: DIC images (scale bar = 25 μm), middle: background fluorescence images, right: zinc-induced response fluorescence images. Micrographs are shown relative to the same intensity scale for direct comparison.
Fig. 2 Fluorescence microscopy images of HeLa cells incubated with ZP1 or [ZP1Mn2]. Left: DIC images (scale bar = 25 μm), middle: background fluorescence images, right: zinc-induced response fluorescence images. Micrographs are shown relative to the same intensity scale for direct comparison.

The displacement of paramagnetic Mn2+ ions (S = 5/2) offers the potential for metal-responsive MRI readout derived from the concurrent change in magnetic relaxation of inner/outer-sphere water molecules. This type of MRI signal generation relies on changes in the number (q) of sites available for water coordination to the manganese center before and after zinc-induced displacement. This approach was recently examined in our laboratories for the detection of Ca2+ ion.8 Moreover, the transmetalation of a manganese complex with zinc ions is reminiscent of the pharmacokinetics of TeslascanTM,14,15 a clinically approved MRI contrast agent containing manganese N,N-dipyridoxylethylenediamine-N,N′-diacetate-5,5′-bis(phosphate) as the active ingredient. The foregoing reports prompted us to consider [ZP1Mn2] as a potential zinc-responsive MRI contrast agent.

For MRI experiments, the central 16 wells of microtiter plates were filled with various samples prepared in buffered aqueous solutions (see ESI for details). Complexation of Mn2+ ion enhances the water-solubility of the complex, a desirable feature for MRI experiments. As shown in Fig. 3, [ZP1Mn2] is zinc-responsive under MRI observation, with T2 decreasing after addition of Zn2+. The corresponding transverse relaxivity (r2) change is ca. 1.7-fold, from 41 (±1) mM−1 s−1 to 67 (±0) mM−1 s−1 and from 40 (±3) mM−1 s−1 to 68 (±4) mM−1 s−1 for perchlorate- and chloride-containing buffer, respectively. These changes are consistent with an increase in q following Mn2+ ion displacement, in agreement with the fluorescence results. Control experiments and relaxivity measurements as a function of zinc concentration unambiguously indicate that [ZP1Mn2] responds to Zn2+ in the micromolar range (ESI). The smaller Δr2 values compared to those observed for our previous systems based on hexadentate chelators (i.e., ethylene glycol-bis(2-aminoethylether)-N,N,N′,N′-tetraacetic acid (EGTA), 1,2-bis(2-aminophenoxy)ethane-N,N,N′,N′-tetraacetic acid (BAPTA))8 are most likely a consequence of water coordination (q > 0) to the Mn2+ center in [ZP1Mn2] prior to zinc addition. Changes in longitudinal relaxivity (r1) computed from T1-weighted MRI signals were within the error of the measurements and hence did not allow estimation of a zinc-induced response.



          T
          2-weighted MRI (TR = 2000 ms, TE = 80 ms, field strength = 200 MHz. Scale bars represent acquired MRI signal intensity (/105)) and transverse relaxivity (r2) of [ZP1Mn2] (0.1 mM) before and after addition of ZnCl2 or Zn(ClO4)2 (2 mM) in 50 mM PIPES buffer containing either KCl or KClO4 (100 mM), respectively, pH 7.0.
Fig. 3 T 2-weighted MRI (TR = 2000 ms, TE = 80 ms, field strength = 200 MHz. Scale bars represent acquired MRI signal intensity (/105)) and transverse relaxivity (r2) of [ZP1Mn2] (0.1 mM) before and after addition of ZnCl2 or Zn(ClO4)2 (2 mM) in 50 mM PIPES buffer containing either KCl or KClO4 (100 mM), respectively, pH 7.0.

To summarize, a paramagnetic Mn2+−fluorophore complex was able to serve as a dual probe for zinc. Mn2+ displacement by Zn2+ ions in ZP1 results in an improved fluorescence dynamic range, both in the cuvette and in live cells. In addition, the successful demonstration of MRI using [ZP1Mn2] suggests a route to dual-modality imaging16 based on paramagnetic displacement strategies. Notably, this dual-mode detection requires neither additional modifications17 nor integration of discrete functionalities18 for fluorescence and MRI readout, because the identical chemical event (Mn2+ displacement) triggers both signal outputs. Although the release of paramagnetic ions is not suitable for all experimental settings, such sensing mechanisms could provide versatile tools to the vibrant field of zinc bioimaging9,10 by allowing description of zinc trafficking at both the cellular and organismal levels.

This work was supported by a grant from the National Institute of General Medical Sciences (Grant GM065519 to SJL). Spectroscopic instrumentation at the MIT DCIF is maintained with funding from NIH Grant 1S10RR13886-01. YY and WN are grateful for financial assistance from RP-Grant 2009 of Ewha Womans University and SBS Foundation, Seoul, Korea, to support their postdoctoral and sabbatical stays at MIT, respectively. TA and APJ acknowledge support from NIH Grant DP2-OD2441 and from the Raymond & Beverley Sackler Foundation.

Notes and references

  1. B. T. Nguyen and E. V. Anslyn, Coord. Chem. Rev., 2006, 250, 3118–3127 CrossRef CAS.
  2. L. Fabbrizzi, A. Leone and A. Taglietti, Angew. Chem., Int. Ed., 2001, 40, 3066–3069 CrossRef CAS.
  3. S. L. Tobey and E. V. Anslyn, Org. Lett., 2003, 5, 2029–2031 CrossRef CAS.
  4. S. A. Hilderbrand, M. H. Lim and S. J. Lippard, J. Am. Chem. Soc., 2004, 126, 4972–4978 CrossRef CAS.
  5. Z. Xu, K.-H. Baek, H. N. Kim, J. Cui, X. Qian, D. R. Spring, I. Shin and J. Yoon, J. Am. Chem. Soc., 2010, 132, 601–610 CrossRef CAS.
  6. L. Xue, Q. Liu and H. Jiang, Org. Lett., 2009, 11, 3454–3457 CrossRef CAS.
  7. G. He, Y. Zhao, C. He, Y. Liu and C. Duan, Inorg. Chem., 2008, 47, 5169–5176 CrossRef CAS.
  8. T. Atanasijevic, X.-a. Zhang, S. J. Lippard and A. Jasanoff, Inorg. Chem., 2010, 49, 2589–2591 CrossRef CAS.
  9. E. L. Que, D. W. Domaille and C. J. Chang, Chem. Rev., 2008, 108, 1517–1549 CrossRef CAS.
  10. E. Tomat and S. J. Lippard, Curr. Opin. Chem. Biol., 2010, 14, 225–230 CrossRef CAS.
  11. G. K. Walkup, S. C. Burdette, S. J. Lippard and R. Y. Tsien, J. Am. Chem. Soc., 2000, 122, 5644–5645 CrossRef CAS.
  12. J. K. Ketterman and Y. V. Li, J. Neurosci. Res., 2007, 86, 422–434.
  13. B. A. Wong, S. Friedle and S. J. Lippard, J. Am. Chem. Soc., 2009, 131, 7142–7152 CrossRef CAS.
  14. K. G. Toft, S. O. Hustvedt, D. Grant, I. Martinson, P. B. Gordon, G. A. Friisk, A. J. Korsmo and T. Skotland, Acta Radiol., 1997, 38, 677–689 CAS.
  15. P. P. Schmidt, K. G. Toft, T. Skotland and K. K. Andersson, J. Biol. Inorg. Chem., 2002, 7, 241–248 CrossRef CAS.
  16. L. E. Jennings and N. J. Long, Chem. Commun., 2009, 3511–3524 RSC.
  17. X.-a. Zhang, K. S. Lovejoy, A. Jasanoff and S. J. Lippard, Proc. Natl. Acad. Sci. U. S. A., 2007, 104, 10780–10785 CrossRef CAS.
  18. J.-H. Lee, Y.-w. Jun, S.-I. Yeon, J.-S. Shin and J. Cheon, Angew. Chem., Int. Ed., 2006, 45, 8160–8162 CrossRef.

Footnote

Electronic supplementary information (ESI) available: Experimental details, fluorescence titrations, fluorescence cell images and MRI data. See DOI: 10.1039/c0cc00179a

This journal is © The Royal Society of Chemistry 2010