Issue 5, 2014

Determination of lead isotope ratios in environmental matrices by quadrupole ICP-MS working at low sample consumption rates

Abstract

Measurement of lead isotope ratios in environmental matrices using inductively coupled plasma-dynamic reaction cell-mass spectrometry at low sample consumption rates was investigated. Two micro-sample introduction systems were evaluated, namely the PFA micronebuliser associated with a low-volume spray chamber, working at 150 μL min−1 and the total-consumption sample introduction system TISIS, operating at 20 μL min−1. In both cases, the dynamic reaction cell pressurised with ammonia was applied to improve the precision by collisional damping. Under optimal operating conditions, 208Pb/207Pb and 206Pb/207Pb ratios were accurately determined with an internal precision of 0.12–0.13% and 0.17–0.18% (%RSD, n = 10, c = 10 μg L−1; t = 10 s). The sample consumption for the assessed sample introduction systems was less than 1.5 mL and 200 μL, allowing the precise analysis of limited-size samples and pre-concentrates. The developed method was characterised in terms of the analytical working range, in-cell interference, and uncertainty estimation. The applicability of the analytical method was demonstrated by the analysis of the lichen reference material CRM 482, as well as those of several environmental samples collected from polar regions, including atmospheric particulate, snow, marine suspended particulate matter and sediment. In particular, by combining a simple pre-concentration procedure with the application of TISIS, it was possible to perform the lead isotope analysis of Antarctic snow samples at the pg g−1 concentration level.

Graphical abstract: Determination of lead isotope ratios in environmental matrices by quadrupole ICP-MS working at low sample consumption rates

Article information

Article type
Paper
Submitted
12 Dec 2013
Accepted
04 Mar 2014
First published
04 Mar 2014

J. Anal. At. Spectrom., 2014,29, 926-933

Determination of lead isotope ratios in environmental matrices by quadrupole ICP-MS working at low sample consumption rates

A. Bazzano and M. Grotti, J. Anal. At. Spectrom., 2014, 29, 926 DOI: 10.1039/C3JA50388G

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.