Issue 15, 2014

Study of fibrinogen adsorption on poly(ethylene glycol)-modified surfaces using a quartz crystal microbalance with dissipation and a dual polarization interferometry

Abstract

Protein adsorption behavior is a key factor that determines whether materials can be used as medical polymer materials. In this study, fibrinogen (Fib) adsorptions on three different poly(ethylene glycol) (PEG) surfaces that differed in chain length and chain density were investigated using a quartz crystal microbalance with dissipation (QCM-D) and a dual polarization interferometry (DPI) with respect to adsorbed masses, viscoelastic properties and chain conformations. On QCM-D chips, PEG chains were tight and in extended brush conformations. Meanwhile, on DPI chips, PEG1000 and PEG2000 may have the same pancake-like conformations, but PEG5000 had a mushroom conformation. Moreover, several bare spaces were observed on the loose pancake-like PEG1000- and PEG2000-modified DPI surfaces. Fib could fully spread on the relatively dense PEG1000-modified DPI surface and partly spread and tightly orient on the relatively sparse PEG2000-modified DPI surface. Thus, grafting density was found to have greater significance in determining Fib adsorption resistance due to its influence on Fib spreading when the chain conformations of hydrophilic molecules were loose pancake-like structures. Furthermore, brush and mushroom structured PEG5000 chains both had high deformation capacity, which excellently resisted protein adsorption by adjusting their conformation to decrease interaction with Fib. Therefore, the Fib adsorption resistance of PEG-modified surface depended on the grafting density of PEG layer and the deformation capacity of the PEG chain.

Graphical abstract: Study of fibrinogen adsorption on poly(ethylene glycol)-modified surfaces using a quartz crystal microbalance with dissipation and a dual polarization interferometry

Article information

Article type
Paper
Submitted
22 Nov 2013
Accepted
07 Jan 2014
First published
08 Jan 2014

RSC Adv., 2014,4, 7716-7724

Study of fibrinogen adsorption on poly(ethylene glycol)-modified surfaces using a quartz crystal microbalance with dissipation and a dual polarization interferometry

Y. Hu, J. Jin, Y. Han, J. Yin, W. Jiang and H. Liang, RSC Adv., 2014, 4, 7716 DOI: 10.1039/C3RA46934D

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.