Real-time release monitoring for water content and mean particle size of granules in lab-sized fluid-bed granulator by near-infrared spectroscopy

Abstract

Simultaneous real-time monitoring of water content and mean particle size in the powder bed of a fluidized-bed granulator was performed by near-infrared (NIR) spectroscopy through a window, and the findings were used to evaluate the granular properties. A powder mixture containing acetaminophen bulk and additive powders was granulated by spraying with 10, 8.5 and 7.5% binder solutions in a lab-size fluid-bed granulator. Change of water content and mean particle size of the granules during fluid-bed granulation were evaluated by weight loss and sieving of the removed granule samples, respectively. The NIR spectra were recorded during the granulation processes, and calibration models to evaluate water content and mean particle size of the granules were developed based on NIR spectra using the partial least squares regression method. The best calibration models to predict water content and mean particle size were obtained by multiplicative scatter correction treatment. The validation results based on external validation NIR spectra also had sufficiently linear relationships. In the predicted water content–time profiles during the granulation processes, the water content increased in the granulation process, and it decreased in the drying process; the predicted values fitted very well to the actual values in all processes. The maximum water content in the processes using 8.5 and 7.5% binder solutions was around 6–7%, but that using 10% binder solution was around 3%. In terms of the predicted mean particle size–time profiles, they increased during the granulation process, and remained constant during the drying process; the predicted profile fitted very well to the actual values in all processes.

Graphical abstract: Real-time release monitoring for water content and mean particle size of granules in lab-sized fluid-bed granulator by near-infrared spectroscopy

Article information

Article type
Paper
Submitted
26 Sep 2013
Accepted
24 Mar 2014
First published
27 Mar 2014

RSC Adv., 2014,4, 17461-17468

Author version available

Real-time release monitoring for water content and mean particle size of granules in lab-sized fluid-bed granulator by near-infrared spectroscopy

M. Otsuka, A. Koyama and Y. Hattori, RSC Adv., 2014, 4, 17461 DOI: 10.1039/C3RA45375H

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements