Issue 10, 2007

Analysis of xenon gas inclusions in nuclear fuel using laser ablation ICP-MS

Abstract

Analysis of fluid and gaseous inclusions in solids have been a major interest in various fields and have been carried out at different pressures, temperatures, and phase conditions. In nuclear fuel, approximately 20% of the fission products (FPs) are gaseous with isotopes of Xe contributing up to 90% to the product gases. However, previous to this work quantitative analysis of Xe inclusions in nuclear fuel samples have not been performed systematically. The method used must incorporate simple sample handling procedures in a shielded environment. This study is the development of a method for the direct determination of the fission gas (FG) products in micro inclusions contained in nuclear fuels using LA-ICP-MS. To determine the concentration of Xe in nuclear fuel, two calibration strategies were investigated. The first strategy was based on the direct injection of a known quantity of a reference gas into the LA-ICP-MS carrier gas system. Further, the ablation of a ‘matrix-matched’ standard of a non-irradiated UO2 sample, implanted with a known amount of 129Xe was also applied. Using these quantification methods, quantitative LA-ICP-MS measurements were performed on high burnup nuclear fuel. This study demonstrates that direct gas injection is most suitable for the quantification of fission gas in micron-sized inclusions. The direct gas addition is simple and linear calibration curves were obtained. Good reproducibility was obtained and matrix effects were within the uncertainty of the measurements. For the quantification of fission gases in nuclear fuel, aerosol particles were filtered before entering the ICP to remove interferences on the Xe isotopes from the solid FP matrix. The first quantitative determinations of the amount of gas in nuclear fuel using the direct injection method for calibration led to sample pressure calculations which were in good agreement with pressures estimated from computer simulations.

Graphical abstract: Analysis of xenon gas inclusions in nuclear fuel using laser ablation ICP-MS

Article information

Article type
Paper
Submitted
13 Apr 2007
Accepted
19 Jun 2007
First published
03 Jul 2007

J. Anal. At. Spectrom., 2007,22, 1266-1274

Analysis of xenon gas inclusions in nuclear fuel using laser ablation ICP-MS

M. Horvath, M. Guillong, A. Izmer, N. Kivel, R. Restani, I. Günther-Leopold, J. Opitz Coutureau, C. Hellwig and D. Günther, J. Anal. At. Spectrom., 2007, 22, 1266 DOI: 10.1039/B705533A

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements