Analytical evaluation of a dual micronebulizer sample introduction system for inductively coupled plasma spectrometry

Abstract

The analytical performance of a dual nebulization system is evaluated for sample nebulization at lower solution uptake rates in inductively coupled plasma optical emission spectrometry (ICP-OES). The system is essentially a modified cyclonic spray chamber that allows the simultaneous operation of two micronebulizers. This work is focused on the optimization and evaluation of the main analytical figures of merit of this sample introduction system. The usefulness of this dual micro-nebulizer in practical ICP-OES studies is demonstrated by using a tandem calibration technique and by operating this system for hydride generation studies. Results showed that this system presents similar figures of merit to a conventional spray chamber but that the non-spectroscopic interferences, usually present at lower solution uptakes rates, can be compensated for by using the tandem calibration technique with this system. Additionally, the two micronebulizers coupled to the modified cyclonic spray chamber can be used for efficient volatile hydride generation from sub-mL amounts of samples. Interference effects by transition metals have been shown to be corrected by the addition of thiourea. The analytical applicability of the dual system was checked by analyzing two standard reference materials: NIST 1577b, Bovine Liver and NIST 1566a Oyster Tissue. The accuracy achieved when using different calibration techniques and hydride generation are within the certified values when applying the significance t-test at the 95% confidence level.

Graphical abstract: Analytical evaluation of a dual micronebulizer sample introduction system for inductively coupled plasma spectrometry

Article information

Article type
Paper
Submitted
17 Mar 2006
Accepted
27 Jun 2006
First published
18 Jul 2006

J. Anal. At. Spectrom., 2006,21, 743-749

Analytical evaluation of a dual micronebulizer sample introduction system for inductively coupled plasma spectrometry

D. Maldonado, J. Chirinos, Z. Benzo, C. Gómez and E. Marcano, J. Anal. At. Spectrom., 2006, 21, 743 DOI: 10.1039/B604044F

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements