Issue 8, 2006

Determination of silicon isotope ratios in silicate materials by high-resolution MC-ICP-MS using a sodium hydroxide sample digestion method

Abstract

Silicon isotope ratios (28Si, 29Si and 30Si) can be measured with high precision by multi-collector inductively coupled plasma mass spectrometers (MC-ICP-MS). However, the problematic extraction of silicon from geological materials has been a major disadvantage in previous silicon isotope studies with conventional gas source mass spectrometry, whereas available silicon isotope results obtained by MC-ICP-MS techniques have been mainly restricted to waters and high purity silica. We show here that high yields of silicon (>97%) can be achieved from samples ranging from pure silica to basaltic compositions (45–52 wt.% SiO2) via a three-step digestion and purification procedure. Silicon isotope measurements, performed with a Finnigan Neptune MC-ICP-MS used in medium-resolution mode (resolving power: 2500), indicate that polyatomic interferences can be resolved and that both δ29Si and δ30Si can be determined with high accuracy and precision on interference-free peak plateaux in the mass spectrum. Instrumental blanks (20–65 mV) were reduced to acceptable values with a Cetac Aridus desolvating device fitted with a sapphire injector in the torch. Sensitivity in medium-resolution mode is in the range of ∼6 V per μg g−1 for 28Si. δ29Si and δ30Si have been determined for silicon isotope standards IRMM-018 (δ30Si = −1.75‰), IRMM-018-76 (δ30Si = −1.42‰), Diatomite (δ30Si = 1.34‰) and Big Batch (δ30Si = −10.52‰), for USGS standards BHVO-2 (δ30Si = −0.09‰) and AGV-2 (δ30Si = −0.01‰), and for Aldrich pure silica powder (δ30Si = −0.32‰). Precision on δ30Si is 0.18–0.41‰ (2 s.d.). Our combined procedure for sample preparation followed by high-resolution MC-ICP-MS analysis facilitates straightforward and safe measurement of silicon isotope ratios in silicate materials.

Graphical abstract: Determination of silicon isotope ratios in silicate materials by high-resolution MC-ICP-MS using a sodium hydroxide sample digestion method

Article information

Article type
Paper
Submitted
25 Jan 2006
Accepted
20 Jun 2006
First published
10 Jul 2006

J. Anal. At. Spectrom., 2006,21, 734-742

Determination of silicon isotope ratios in silicate materials by high-resolution MC-ICP-MS using a sodium hydroxide sample digestion method

S. H. J. M. van den Boorn, P. Z. Vroon, C. C. van Belle, B. van der Wagt, J. Schwieters and M. J. van Bergen, J. Anal. At. Spectrom., 2006, 21, 734 DOI: 10.1039/B600933F

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements